Elite.Parts chervon right Manufacturers chervon right E chervon right EDWARDS SIGNALING & SECURITY SYSTEMS chervon right SIGA-CT2
About product Specifications Datasheet FAQ

EDWARDS SIGNALING & SECURITY SYSTEMS SIGA-CT2

Description

Edwards Signaling & Security Systems SIGA-CT2 PLC Analog Output Modules - Intelligent Input/Output Modules

Part Number

SIGA-CT2

Price

Request Quote

Manufacturer

EDWARDS SIGNALING & SECURITY SYSTEMS

Lead Time

Request Quote

Category

PRODUCTS - S

Specifications

Address Requirements

Uses Two Module Addresses

Compatibility

Use with Signature Loop Controller

Construction

High Impact Engineering Polymer

LED Operation

On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active Both LEDs - Glow steady when in alarm (stand-alone)

Operating Current

Standby

Operating Voltage

15.2 to 19.95 Vdc (19 Vdc nominal)

Type Code

49 (factory set) Four sub-types (personality codes) are available

Datasheet

pdf file

SIGA-CT2_Datashee-1502180524t.pdf

246 KiB

Extracted Text

GE EST Life Safety & Communications Security Intelligent Input/Output Overview Standard Features The SIGA-CT1 Single Input Module and SIGA-CT2/SIGA-MCT2 Dual • Multiple applications Input Modules are intelligent analog addressable devices used to Including Alarm, Alarm with delayed latching (retard) for water- connect one or two Class B normally-open Alarm, Supervisory, or flow applications, Supervisory, and Monitor. The installer selects Monitor type dry contact Initiating Device Circuits (IDC). one of four “personality codes” to be downloaded to the module through the loop controller. The actual function of these modules is determined by the “personality • SIGA-CT1 rated for high temperature environments code” selected by the installer. This code is downloaded to the module Suitable for attic installation and monitoring high temperature from the Signature loop controller during system configuration. heat detectors. The input modules gather analog information from the initiating • Plug-in (UIO) or standard 1-gang mount devices connected to them and convert it into digital signals. The UIO versions allow quick installation where multiple modules are module’s on-board microprocessor analyzes the signal and decides required. The 1-gang mount version is ideal for remote locations whether or not to input an alarm. that require a single module. The SIGA-CT1 and SIGA-CT2 mount to standard North American • Automatic device mapping 1-gang electrical boxes, making them ideal for locations where only Signature modules transmit information to the loop controller one module is required. Separate I/O and data loop connections are regarding their circuit locations with respect to other Signature made to each module. devices on the wire loop. • Electronic addressing The SIGA-MCT2 is part of the UIO family of plug-in Signature Series Programmable addresses are downloaded from the loop control- modules. It functions identically to the SIGA-CT2, but takes advan- ler, a PC, or the SIGA-PRO Signature Program/Service Tool. There tage of the modular flexibility and easy installation that character- are no switches or dials to set. izes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on • Stand-alone operation the motherboard. UIO assemblies may be mounted in GE Security The module makes decisions and inputs an alarm from initiating enclosures. devices connected to it even if the loop controller’s polling interro- gation stops. (Function availability dependent upon control panel.) • Ground fault detection by address Detects ground faults right down to the device level. Input Modules SIGA-CT1, SIGA-CT2 & SIGA-MCT2 SIGA-CT1/2 S SIGA-MCT2 CHINA MEA Application Notes Available Data Sheet 85001-0241 Issue 7 Not to be used for installation purposes. Page 1 of 4 UIO Motherboard Signature Series Overview 6-32 The Signature Series intelligent analog-addressable system from Self-tapping screws GE Security is an entire family of multi-sensor detectors and mount- ing bases, multiple-function input and output modules, network and non-network control panels, and user-friendly maintenance Captive Plug-in (UIO) screws and service tools. Analog information from equipment connected Module to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. #6 Flat washers The microprocessor in each Signature device provides four addi- Cabinet or electrical enclosure tional benefits – Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log – Each Signature Series device Electronic Addressing - The loop controller electronically addresses constantly runs self-checks to provide important maintenance each module, saving valuable time during system commissioning. information. The results of the self-check are automatically updated Setting complicated switches or dials is not required. Each module and permanently stored in its non-volatile memory. This informa- has its own unique serial number stored in its on-board memory. tion is accessible for review any time at the control panel, PC, or The loop controller identifies each device on the loop and assigns a using the SIGA-PRO Signature Program/Service Tool. “soft” address to each serial number. If desired, the modules can be Automatic Device Mapping –The Signature Data Controller (SDC) addressed using the SIGA-PRO Signature Program/Service Tool. learns where each device’s serial number address is installed rela- GE Security recommends that this module be installed according to tive to other devices on the circuit. The SDC keeps a map of all Sig- latest recognized edition of national and local fire alarm codes. nature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or “as-built” drawing information showing branch wiring (T-taps), device types and their address are stored on disk for Application printing hard copy. The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or “Personality Code”. The code is selected by the installer depending upon the desired application Installation and is downloaded from the loop controller. SIGA-CT1 and SIGA-CT2: modules mount to North American 2½ One personality code can be assigned to the SIGA-CT1. Two person- inch(64 mm) deep 1-gang boxes and 1½ inch (38 mm) deep 4 inch ality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 square boxes with 1-gang covers and SIGA-MP mounting plates. 2 2 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, The terminals are suited for #12 to #18 AWG (2.5 mm to 0.75 mm ) personality code 1 can be assigned to the first address (circuit A) wire size. and code 4 can be assigned to the second address (circuit B). Compatible electrical box NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - As- sign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop Wall plate, white (1-gang) controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Personality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiating devices such as Waterflow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop SIGA-MCT2: mount the UIO motherboard inside a suitable GE Secu- controller when the input contact is closed. The active condition is rity enclosure with screws and washers provided. Plug the SIGA- not latched at the module. MCT2 into any available position on the motherboard and secure NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign the module to the motherboard with the captive screws. Wiring to one or both circuits. Configures either circuit A or B or both for connections are made to the terminals on the motherboard (see Class B normally open dry contact monitoring input such as from wiring diagram). UIO motherboard terminals are suited for #12 to Supervisory and Tamper Switches. An ACTIVE signal is sent to the 2 2 #18 AWG (2.5 mm to 0.75 mm ) wire size. loop controller when the input contact is closed. The active condi- tion is latched at the module. Data Sheet 85001-0241 Issue 7 Not to be used for installation purposes. Page 2 of 4 FIREALARM MODULE Typical Wiring 2 2 2 2 Modules will accept #18 AWG (0.75mm ), #16 (1.0mm ), and #14AWG (1.50mm ), and #12 AWG (2.50mm ) wire sizes. 2 2 Note: Sizes #16 AWG (1.0mm ) and #18 AWG (0.75mm ) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1µF per Circuit Maximum Distance to EOLR For Design Reference: Wire Size #18 AWG (0.75 mm²) #16 AWG (1.00 mm²) 4,000 ft (1,219 m) #14 AWG (1.50 mm²) #12 AWG (1.50 mm²) SIGA-CT2 SIGA-CT1 Typical NO Initiating Device NOTES UL/ULC Listed UL/ULC Listed Input 2 Input 1 47KW EOL 47KW EOL 1 Maximum 25 Ohm resistance per wire. 2 Maximum #12 AWG (2.5 mm² ) wire; Minimum #18 AWG (0.75 mm2). 1 2 4 3 Refer to Signature controller installation sheet for wiring specifications. 4 Maximum 10 Vdc @ 350 µA MCT2 1 2 3 4 UIO(R) series motherboard 5 The SIGA-UIO6R and the SIGA-UIO2R do not come with TB14. 3 6 All wiring is supervised and power-limited. 4 Data In 3 5 2 7 These modules will not support 2-wire smoke detectors. 4 1 3 Signature TB14 No connections required for 2 Data MCT2 1 Circuit TB7 Other modules may require connections. Data Out 4 3 Warnings & Cautions 2 1 Green LED (Normal) TB15 This module will not operate without electrical power. As fires fre- Red LED (Active) 1 2 3 4 quently cause power interruption, we suggest you discuss further No connections or jumper settings safeguards with your local fire protection specialist. required for MCT2. SIGA-MCT2 Compatibility The Signature Series modules are compatible only with GE Securi- ty’s Signature Loop Controller. Data Sheet 85001-0241 Issue 7 Not to be used for installation purposes. Page 3 of 4 CAT NO. MCT2 473387351 GE Security U.S. Specifications T 888-378-2329 F 866-503-3996 Catalog Number SIGA-CT1 SIGA-CT2 SIGA-MCT2 Canada Dual Input Module Description Single Input Module T 519 376 2430 49 (factory set) Four sub-types (personality Type Code 48 (factory set) Four F 519 376 7258 codes) are available sub-types (personality Asia codes) are available T 852 2907 8108 Uses Two Module Addresses Address Requirements Uses One Module Ad- F 852 2142 5063 dress Australia Standby = 396µA; Activated = 680µA Operating Current Standby = 250µA; T +61 3 9239 1200 Activated = 400µA F +61 3 9239 1299 15.2 to 19.95 Vdc (19 Vdc nominal) Operating Voltage Europe High Impact Engineering Polymer Construction T 32 2 725 11 20 UIO2R/6R/6 Mother- Mounting North American 2½ inch (64 mm) deep one-gang F 32 2 721 86 13 board boxes and 1½ inch (38 mm) deep 4 inch square Latin America boxes with one-gang covers and SIGA-MP T 305 593 4301 mounting plates F 305 593 4300 Operating Tempera- Storage and Operating Operating Temperature: 32°F to 120°F ture: 32°F to 158°F Environment www.gesecurity.com/est (0°C to 49°C) (0°C to 70°C) Storage Temperature: Storage Temperature: -4°F to 140°F © 2009 General Electric Company All Rights Reserved -4°F to 140°F (-20°C to 60°C) (-20°C to 60°C); Humidity: 0 to 93% RH Humidity: 0 to 93% RH Signature Series is a Trademark On-board Green LED - Flashes when polled; On-board Red LED - Flashes LED Operation of GE Security. when in alarm/active Both LEDs - Glow steady when in alarm (stand-alone) Use with Signature Loop Controller Compatibility UL, ULC, MEA, CSFM Agency Listings Ordering Information Catalog Description Ship Wt. Number lbs (kg) SIGA-CT1 Single Input Module — UL/ULC Listed 0.4 (0.15) SIGA-CT2 Dual Input Module — UL/ULC Listed 0.4 (0.15) SIGA-MCT2 Dual Input Plug-in (UIO) Module — UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0 (0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0 (0.6) SIGA-UIO2R Universal Input-Output Module Board w/Riser Inputs 0.32 (0.15) — Two Module Positions SIGA-UIO6R Universal Input-Output Module Board w/Riser Inputs 0.62 (0.28) — Six Module Positions SIGA-UIO6 Universal Input-Output Module Board — Six Module Positions 0.56 (0.25) MFC-A Multifunction Fire Cabinet — Red, supports Signature Module 7.0 (3.1) Mounting Plates SIGA-MB4 Transponder Mounting Bracket (allows for mounting 0.4 (0.15) two 1-gang modules in a 2-gang box) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Data Sheet 85001-0241 Issue 7 Not to be used for installation purposes. Page 4 of 4

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the SIGA-CT2 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Edwards Signaling & Security Systems SIGA-DH Systems - Intelligent Duct Smoke Detector Housing 85001...

product

Edwards Signaling & Security Systems SIGA-CR Relay Module - Intelligent analog addressable devices,...

product

Edwards Signaling SIGA-IPHS GE-FIRE Intelligent 4D Multisensor Detector Heat

product

Edwards Signaling & Security Systems SIGAPS Photoelectric Smoke Detector