EDWARDS SIGNALING & SECURITY SYSTEMS SIGAPS
Specifications
Address Requirements
Uses one Device Address
Agency Listings
UL, ULC, MEA, CSFM
Compatibility
Use With: SIGNATURE Loop Controller
Construction & Finish
High Impact Engineering Polymer - White
LED Operation
On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm Both LEDs - Glow steady when in alarm (stand-alone) Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm
Operating Current
Quiescent: 45µA @ 19 V; Alarm: 45µA @ 19 V Emergency Stand-alone Alarm Mode: 18mA Pulse Current: 100 µA (100 msec); Durin
Operating Voltage
15.2 to 19.95 Vdc (19 Vdc nominal)
Pre-alarm Sensitivity
5% increments, allowing up to 20 pre-alarm settings
Sensing Element
Photoelectric - Light Scattering Principle
Sensitivity Range
ULI/ULC - 0.67% to 3.77% obscuration/foot
Storage & Operating Environment
Air Velocity Range: 0 to 5,000 ft/min (0 to 25.39 m/s)
UL Listed Spacing
30 ft
User Selected Alarm Sensitivity Settings
Most Sensitive: 1.0%/ft.; More Sensitive: 2.0%/ft.; Normal: 2.5%/ft.; Less Sensitive: 3.0%/ft.; Least Sensitive: 3.5%/ft.
Features
- Automatic day/night sensitivity adjustment
- Automatic mapping device
- Designed and manufactured to ISO 9001 standards
- Electronic addressing
- Environmental compensation
- Identification of dirty or defective detectors
- Integral microprocessor
- Intelligent detector
- Non-volatile memory
- Standard, relay, fault isolator, and audible mounting bases
- Twenty pre-alarm sensitivity values, set in 5% increments
- Twin RED/GREEN status LEDs
- Wide 0.67% to 3.77%/ft. sensitivity range
Datasheet
Edwards Signaling-85001-0269 -- Intelligent PS Multisensor Detector-Datasheet-1849869544.pdf
1113 KiB
Extracted Text
GE EST Fire & Life Safety Security Intelligent Initiating Devices Fast Stable Communication - On-board intelligence means less Overview information needs to be sent between the detector and the loop The Signature Series Model SIGA-PS Intelligent Photoelectric Smoke controller. Other than regular supervisory polling response, the Detector gathers analog information from its smoke sensing ele- detector only needs to communicate with the loop controller when ment and converts it into digital signals. The detector’s on-board it has something new to report. microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not Standard Features typical of fires. Unwanted alarms are virtually eliminated. • Integral microprocessor The microprocessor in each detector provides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, • Non-volatile memory Stand-alone Operation and Fast, Stable Communication. • Automatic mapping device Self-diagnostics and History Log - Each Signature Series detec- • Electronic addressing tor constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated • Environmental compensation and permanently stored in the detector’s non-volatile memory • Intelligent detector Automatic Device Mapping - The loop controller learns where each • Wide 0.67% to 3.77%/ft. sensitivity range device’s serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each • Twenty pre-alarm sensitivity values, set in 5% increments device’s installed location to prevent a detector from being rein- • Identification of dirty or defective detectors stalled (after cleaning etc.) in a different location from where it was • Automatic day/night sensitivity adjustment originally. • Twin RED/GREEN status LEDs Stand-alone Operation - A decentralized alarm decision by the detector is guaranteed. On-board intelligence permits the detector • Standard, relay, fault isolator, and audible mounting bases to operate in stand-alone mode. If loop controller CPU communica- • Designed and manufactured to ISO 9001 standards tions fail for more than four seconds, all devices on that circuit go into stand-alone mode. The circuit acts like a conventional alarm receiving circuit. Intelligent Photoelectric Smoke Detector SIGA-PS S CHINA Application Notes Available Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 1 of 4 Installation Accessories Signature Series detectors mount to North American 1-gang boxes, All detector mounting bases have wiring terminals that are acces- sible from the “room-side” after mounting the base to the electrical 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical box. The bases mount to North American 1-gang boxes and to 3½ boxes 1-1/2 inches (38 mm) deep. They mount to European BESA inch or 4 inch octagon boxes, 1½ inches (38 mm) deep. They also and 1-gang boxes with 60.3 mm fixing centers. mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SIGA-IB4 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt which is used to cover the “mounting ears” on the base. The SIGA-AB4G mounts to a 4” sqare box only. SIGA-AB4G SIGA-SB SIGA-IB SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base SIGA-SB, SIGA-SB4 - This is the basic mounting base for GE Security Signature Series detectors. The SIGA-LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SIGA-RB4 - This base includes a relay. Nor- mally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay’s position is supervised to avoid accidentally jarring it out of position. The SIGA- RB can be operated as a control relay if programmed to do so at the control panel (EST3 V.2 only). The relay base does not support the SIGA-LED Remote LED. Testing & Maintenance Audible Base SIGA-AB4G - This base is designed for use where Each detector automatically identifies when it is dirty or defective localized or group alarm signaling is required. When the detector and causes a “dirty detector” message. The detector’s sensitiv- senses an alarm condition, the audible base emits a local alarm ity measurement can also be transmitted to the loop controller. A signal. The optional SIGA-CRR Polarity Reversal Relay can be used for sensitivity report can be printed to satisfy NFPA sensitivity measure- sounding to other audible bases on the same 24 Vdc circuit. ments which must be conducted at the end of the first year and Relay and Audible Bases operate as follows: every two years thereafter. - at system power-up or reset, the relay is de-energized The user-friendly maintenance program shows the current state - when a detector is installed in the base with the power of each detector and other pertinent messages. Single detectors on, the relay energizes for four seconds, then de-energizes may be turned off temporarily from the control panel. Availability of - when a detector is removed from a base with the power on, maintenance features is dependent on the fire alarm system used. the relay is de-energized Scheduled maintenance (Regular or Selected) for proper detector - when the detector enters the alarm state, the relay is energized. operation should be planned to meet the requirements of the Au- thority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC Isolator Base SIGA-IB, SIGA-IB4 - This base includes a built-in line CAN/ULC 536 standards. fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. Compatibility The isolator operates as follows: The SIGA-PS detectors are compatible only with the Signature Loop - a short on the line causes all isolators to open within 23 msec Controller. - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, reopens within 10 msec. Warnings & Cautions The process repeats beginning on the other side of the loop con- This detector will not operate without electrical power. As fires fre- troller. quently cause power interruption, we suggest you discuss further Remote LED SIGA-LED - The remote LED connects to the SIGA-SB safeguards with your fire protection specialist. or SIGA-SB4 Standard Base only. It features a North American size This detector will NOT sense fires that start in areas where smoke 1-gang plastic faceplate with a white finish and red alarm LED. cannot reach the detector. Smoke from fires in walls, roofs, or on the SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be opposite side of closed doors may not reach the detector to alarm it. ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 2 of 4 Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. GE Security recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. SIGA-HRS and SIGA- HFS Rate-of-Rise/ SIGA-PHS SIGA-IPHS Test Fire SIGA-IS Ion SIGA-PS Photo Fixed Temp. Photo Heat D Ion/Photo/Heat 4D Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum very suitable unsuitable Smouldering Cotton optimum optimum optimum Poly Urethane Foam very suitable very suitable suitable very suitable optimum n-Heptane optimum very suitable very suitable optimum optimum Liquid Fire without Smoke unsuitable unsuitable optimum very suitable very suitable Typical Wiring 2 2 2 The detector mounting bases accept #18 AWG (0.75mm ), #16 (1.0mm ), #14 AWG (1.5mm ), and #12 AWG (2.5mm²) wire sizes. 2 2 Note: Sizes #16 AWG (1.0mm ) and #18 AWG (0.75mm ) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Relay Detector Base, SIGA-RB, SIGA-RB4 Standard Detector Base, SIGA-SB, SIGA-SB4 Term Description Term Description 1 Normally Open 1 Not Used 2 DATA IN/OUT (+) 2 DATA IN/OUT (+) 3 Common 3 Not Used 4 DATA IN (-) 4 DATA IN (-) 5 Not Used 5 Remote LED (-) 6 Normally-Closed 6 Remote LED (+) 7 DATA OUT (-) 7 Not Used 8 DATA OUT (-) CONTACT RATING 1.0 Amp @ 30 VDC (Pilot Duty) Isolator Detector Base, SIGA-IB, SIGA-IB4 Audible Detector Base, SIGA-AB4G Term Description 1 Not Used Volumesetting Tonesetting 2 DATA IN/OUT (+) Default=Highvolume Default=Temporalpattern 3 DATA IN (-) Cutforlowvolume Cutforsteadytone 4 Not Used DATA- DATA- DATA+ 5 Not Used OUT IN IN/OUT SIG+ SIG- 6 DATA OUT (-) 7 Not Used Toconfigureoutputvolume ortone,cutthecircuitboard asshown. 24Vdcin - - 24Vdcout Frompowersupplyor + + TonextbaseorEOLrelay previousbase - Datain - Dataout FromSignaturecontrolleror + + TonextSignaturedevice previousdevice Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page of 4 U.S. Specifications T 888-378-2329 F 866-503-3996 Sensing Element Photoelectric - Light Scattering Principle Storage & Operating Air Velocity Range: 0 to 5,000 ft/min (0 to 25.39 m/s); Humidity: 0 to 93% Canada T 519 376 2430 Environment RH, Non-Condensing Operating Temp: 32ºF to 120ºF (0ºC to 49ºC); Stor- F 519 376 7258 age Temp: -4ºF to 140ºF (-20ºCto 60ºC) Sensitivity Range ULI/ULC - 0.67% to 3.77% obscuration/foot Asia User Selected Alarm Most Sensitive: 1.0%/ft.; More Sensitive: 2.0%/ft.; Normal: 2.5%/ft.; Less T 852 2907 8108 F 852 2142 5063 Sensitivity Settings Sensitive: 3.0%/ft.; Least Sensitive: 3.5%/ft. Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings Australia Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) T 61 3 9259 4700 Operating Current Quiescent: 45µA @ 19 V; Alarm: 45µA @ 19 V Emergency Stand-alone F 61 3 9259 4799 Alarm Mode: 18mA Pulse Current: 100 µA (100 msec); During Communi- Europe cation: 9 mA max. T 32 2 725 11 20 Construction & Finish High Impact Engineering Polymer - White F 32 2 721 86 13 Compatible Mounting SIGA-SB Standard Base, SIGA-RB Relay Base, SIGA-IB Isolator Base, SIGA- Latin America Bases AB4, SIGA-AB4G Audible Bases T 305 593 4301 LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes F 305 593 4300 when in alarm Both LEDs - Glow steady when in alarm (stand-alone) Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm www.gesecurity.com Compatibility Use With: SIGNATURE Loop Controller © 2006 General Electric Company Address Requirements Uses one Device Address All Rights Reserved Agency Listings UL, ULC, MEA, CSFM UL Listed Spacing 30 ft Signature Series is a Trademark of GE Security. Ordering Information Catalog Description Ship Wt. Number lbs (kg) SIGA-PS Intelligent Photoelectric Detector - UL/ULC Listed 0.5 (.23) Accessories SIGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS4 Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w SIGA-TS4 Trim Skirt 0.2 (.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible (Sounder) Base .3 (0.15) SIGA-TS4 Trim Skirt (supplied with 4-inch bases) .1 (.04) Data Sheet 85001-0269 Issue 6 Not to be used for installation purposes. Page 4 of 4
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the SIGAPS have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
Edwards Signaling & Security Systems SIGA-DH Systems - Intelligent Duct Smoke Detector Housing 85001...
Edwards Signaling & Security Systems SIGA-CR Relay Module - Intelligent analog addressable devices,...
Manufacturers




What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods