Edwards Signaling & Security Systems SIGA-CR Relay Module - Intelligent analog
addressable devices, control relay

Part Number

SIGA-CR

Price

Request Quote

Manufacturer

EDWARDS SIGNALING & SECURITY SYSTEMS

Lead Time

Request Quote

Category

PRODUCTS - S

Specifications

Address Requirements

Uses 1 Module Address

Agency Listings

UL, ULC, CSFM, MEA

Compatibility

Use With: Signature Loop Controller

Construction & Finish

High Impact Engineering Polymer

LED Operation

On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active

Mounting

North American 2½ inch (64 mm) deep 1-gang boxes and 1½ inch (38 mm) deep, 4 inch square boxes with 1-gang covers and SIGA-MP mounting plates

Operating Current Standby

100µA Activated - 100µA

Operating Voltage

15.2 to 19.95 Vdc (19 Vdc nominal)

Relay Type and Rating Form

“C” 24 VDC - 2 amps (pilot duty) 120 Vac - 0.5 amps 220 Vac (non-UL) - 0.5 amps

Storage and Operating Environment

Operating Temperature: 32°F to 120°F (0°C to 49°C) , Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH

Type Code

Personality Code 8 (Factory Set)

Features

Datasheet

pdf file

SIGA-CR_D-1851614333S.pdf

438 KiB

Extracted Text

GE EST Fire & Life Safety Security Intelligent Input/Output Overview Standard Features The Control Relay Module and the Polarity Reversal Relay Module • Provides one no/nc contact (SIGA-CR/MCR) are part of the Signature Series system. They are intelligent analog Form “C” dry relay contact can be used to control external appli- addressable devices available in either plug-in (UIO) versions, or ances such as door closers, fans, dampers etc. standard 1-gang mount versions. • Allows group operation of sounder bases The SIGA-CRR/MCRR reverses the polarity of its 24 Vdc output, The SIGA-CR/MCR Control Relay Module provides a Form “C” dry thus activating all Sounder Bases on the data loop. relay contact to control external appliances such as door closers, fans, dampers etc. This device does not provide supervision of the • Plug-in (UIO) or standard 1-gang mount state of the relay contact. Instead, the on-board microprocessor UIO versions allow quick installation where multiple modules are ensures that the relay is in the proper ON/OFF state. Upon com- required. The 1-gang mount version is ideal for remote locations mand from the loop controller, the SIGA-CR/MCR relay activates the that require a single module. normally open or normally-closed contact. • Automatic device mapping Signature modules transmit information to the loop controller The SIGA-CRR/MCRR Polarity Reversal Relay Module provides a regarding their circuit locations with respect to other Signature Form “C” dry relay contact to power and activate a series of SIGA- devices on the wire loop. AB4G Audible Sounder Bases. Upon command from the Signature loop controller, the SIGA-CRR reverses the polarity of its 24 Vdc • Electronic addressing output, thus activating all Sounder Bases on the data loop. Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; Standard-mount versions (SIGA-CR and SIGA-CRR) are installed there are no switches or dials to set. to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O • Intelligent device with microprocessor and data loop connections are made to each module. All decisions are made at the module to allow lower communica- tion speed with substantially improved control panel response Plug-in UIO versions (SIGA-MCR and SIGA-MCRR) are part of the time and less sensitivity to line noise and loop wiring properties; UIO family of plug-in Signature Series modules. They function twisted or shielded wire is not required. identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all • Ground fault detection by address UIO modules. Two- and six-module UIO motherboards are available. Detects ground faults right down to the device level. All wiring connections are made to terminal blocks on the mother- board. UIO assemblies may be mounted in GE Security enclosures. Control Relay Modules SIGA-CR, SIGA-MCR, SIGA-CRR, MEA SIGA-MCRR SIGA-CRx SIGA-MCRx Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 1 of 6 Installation Application SIGA-CR and SIGA-CRR: modules mount to North American 2½ The operation of Signature Series control relays is determined by inch (64 mm) deep 1-gang boxes and 1½ inch (38 mm) deep 4 inch their sub-type code or “Personality Code.” square boxes with 1-gang covers and SIGA-MP mounting plates. Personality Code 8: CONTROL RELAY (SIGA-CR/MCR) - Dry Contact 2 2 The terminals are suited for #12 to #18 AWG (2.5 mm to 0.75 mm ) Output. This setting configures the module to provide one Form “C” wire size. DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp @ 24 Vdc; 0.5 amp @ 120 Vac (or 220 Vac for non-UL applications). Personality Code 8 is assigned at the fac- Compatibleelectricalbox tory. No user configuration is required. Personality Code 8: POLARITY REvERSAL RELAY MODULE (SIGA- CRR/MCRR). This setting configures the module to reverse the polarity of its 24 Vdc output. Contact rating is 2.0 amp @ 24 Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user Wallplate,white configuration is required. (1-gang) Compatibility The Signature Series modules are compatible only with GE Securi- ty’s Signature Loop Controller. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. SIGA-MCR and SIGA-MCRR: mount the UIO motherboard inside a suitable GE Security enclosure with screws and washers provided. Plug the module into any available position on the motherboard Testing & Maintenance and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard The module’s automatic self-diagnosis identifies when it is defective (see wiring diagram). UIO motherboard terminals are suited for #12 and causes a trouble message. The user-friendly maintenance pro- 2 2 to #18 AWG (2.5 mm to 0.75 mm ) wire size. gram shows the current state of each module and other pertinent messages. Single modules may be turned off (deactivated) tempo- UIO Motherboard rarily, from the control panel. Availability of maintenance features is 6-32 dependent on the fire alarm system used. Scheduled maintenance Self-tapping (Regular or Selected) for proper system operation should be planned screws to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Plug-in (UIO) Captive screws Module #6 Flat washers Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a “soft” address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. GE Security recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 2 of 6 FIREALARM MODULE Typical Wiring 2 2 2 2 Modules will accept #18 AWG (0.75mm ), #16 (1.0mm ), #14 AWG (1.50mm ) and #12 AWG (2.5mm ) wire sizes. 2 2 Note: Sizes #16 AWG (1.0mm ) and #18 AWG (0.75mm ) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Notes 1 Refer to Signature Loop Controller Installation Sheet for wiring specifications. 2 NFPA 72 requires that the SIGA-CR/SIGA-MCR be installed in the same room as the device it is control- ling. This requirement may not apply in all markets. Check with your local AHJ for details. 3 The SIGA-UIO6R and the SIGA-UIO2R do not come with TB14. SIGA-CR Control Relay 4 The SIGA-UIO6 does not come with TB8 through TB13. 5 Supervised and power-limited. NormallyOpen Common NormallyClosed 6 If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 2 2 7) Maximum #12 AWG (2.5mm ) wire. 2 Min. #18 (0.75mm ). 1234 1 DataIn 3 4 4 3 3 2 2 1 1 TB7 TB14 Noconnectionsrequiredfor SIGA-MCR.Othermodules DataOut mayrequireconnections. 4 3 2 1 GreenLED(Normal) RedLED(Active) TB15 1234 4 Noconnectionsrequiredfor SIGA-MCR.Othermodules mayrequireconnections. SIGA-MCR Control Relay Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 3 of 6 CATNO. SIGA-MCR EDWARDSSYSTEMSTECHNOLOGY 473387358 Typical Wiring 2 2 2 2 Modules will accept #18 AWG (0.75mm ), #16 (1.0mm ), #14 AWG (1.50mm ) and #12 AWG (2.50mm ) wire sizes. 2 2 Note: Sizes #16 AWG (1.0mm ) and #18 AWG (0.75mm ) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. SIGA-AB4G SIGA-AB4G SIGA-AB4G AudibleBase AudibleBase AudibleBase 6254A-003 EOLRelay Listed24VDC + + 1 NominalPower 2 Supply -- 1 2 2 2 2 1 2 3 3 SIGA-CT1 3 SIGA-CR SIGA-CRR SIGA-CRR 3 Signature ++ 3 Controller OptionalSIGA-CR 3 - fordisabling/disconnecting sounderbase SIGA-MCRR SIGA-CRR Schematic SIGA-MCRR Schematic SIGA-CRRSchematic PowerInPowerOut 6254A-003 Polarityreverses whenactivated. EOLRelay Audible requiredfor Bases supevision 7 8 7 Signature Data DataOut Notes Circuit Fornormaloperation SIGA-CT1 1 Refer to the Signature controller installation sheet for ForGeneralFire wiring. 8 AlarmOperation UL/ULCListed 4 3 2 1 2 One Pair of Wires (24 Vdc power). 24Vdcpower or supply 3 One Pair of Wires (Signature Data). 4 Single Wire (24 Vdc power). 1234 1234 5 The SIGA-UIO6R and the SIGA-UIO2R do not come with SIGA-MCRR TB14. 1 7 SIGA-UIO(R)seriesmotherboard 4 DataOut 6 The SIGA-UIO6 does not come with TB8 through TB13. 3 2 Noconnectionsrequiredfor 1 7 Supervised and power-limited. 4 Signature 5 SIGA-MCRR.Othermodules 3 TB14 Data 2 mayrequireconnections. 8 If the source is nonpower-limited, maintain a space of Circuit 1 1/4 inch from power-limited wiring or use FPL, FPLP, TB7 FPLR, or an equivalent in accordance with the National DataIn Electrical Code. 4 GreenLED(Normal) 3 RedLED(Active) 9 Maximum #12 AWG (2.5 mm² ) wire; Minimum #18 2 1 AWG (0.75 mm² ). Noconnectionsrequiredfor TB15 SIGA-MCRR.Othermodules GreenLED(Normal) 10 End-of-Line Relay must monitor and report power sup- mayrequireconnections. 1234 1234 RedLED(Active) ply trouble to control panel. 6 6 11 Class B Data wiring may be “T-tapped.” OptionalSIGA-MCRR orSIGA-MCRfor NoconnectionsrequiredforSIGA-MCRR. disabling/disconnecting Othermodulesmayrequireconnections. anaudiblebase. Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page  of 6 DATA CATNO. SIGA-MCRR EDWARDSSYSTEMSTECHNOLOGY 473387360 CATNO. SIGA-MCRR SIG+ EDWARDSSYSTEMSTECHNOLOGY SIG- 473387359 DATA(-)OUT DATA(-)IN DATA(+)IN/OUT 4 3 2 1 5 6 7 8 9 10 11 Specifications Catalog Number SIGA-CR SIGA-MCR SIGA-CRR SIGA-MCRR Description Control Relay Polarity Reversal Relay Type Code Personality Code 8 (Factory Set) Personality Code 8 (Factory Set) Address Requirements Uses 1 Module Address Operating Current Standby = 100µA Activated = 100µA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Relay Type and Rating Form “C” 24 VDC = 2 amps (pilot duty) 120 Vac = 0.5 amps 220 Vac (non-UL) = 0.5 amps Mounting North American 2½ inch Plugs into UIO2R, UIO6R or North American 2½ inch Plugs into UIO2R, UIO6R or (64 mm) deep 1-gang boxes UIO6 Motherboards (64 mm) deep 1-gang boxes UIO6 Motherboards and 1½ inch (38 mm) deep and 1½ inch (38 mm) deep 4 inch square boxes with 4 inch square boxes with 1-gang covers and SIGA-MP 1-gang covers and SIGA-MP mounting plates mounting plates Construction & Finish High Impact Engineering Polymer Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC, CSFM, MEA Ordering Information Catalog Number Description Ship Weight - lbs (kg) SIGA-CR Control Relay Module (Standard Mount) - UL/ULC Listed 0.4 (0.15) SIGA-MCR Control Relay Module (UIO Mount) - UL Listed 0.18 (0.08) SIGA-CRR Polarity Reversal Relay Module (Standard Mount) - UL/ULC Listed 0.4 (0.15) SIGA-MCRR Polarity Reversal Relay Module (UIO Mount) - UL Listed 0.18 (0.08) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1 (0.6) 27193-16 Surface Mount Box - White, 1-gang 1 (0.6) SIGA-UIO2R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) SIGA-UIO6R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) SIGA-UIO6 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) SIGA-AB4G Audible (Sounder) Detector Base 0.3 (0.15) Accessories MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0 (3.1) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 5 of 6 GE Security U.S. Signature Series Overview T 888-378-2329 F 866-503-3996 The Signature Series intelligent analog-addressable system from GE Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and out- Canada put modules, network and non-network control panels, and user-friendly maintenance T 519 376 2430 F 519 376 7258 and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature Asia device measures and analyzes the signal and decides whether or not to input an alarm. The T 852 2907 8108 F 852 2142 5063 microprocessor in each Signature device provides four additional benefits – Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Com- Australia munication. T 61 3 9259 4700 F 61 3 9259 4799 Self-diagnostics and History Log – Each Signature Series device constantly runs self- checks to provide important maintenance information. The results of the self-check are Europe T 32 2 725 11 20 automatically updated and permanently stored in its non-volatile memory. This information F 32 2 721 86 13 is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. The information stored in device memory includes: Latin America T 305 593 4301 • Device serial number, address, and type F 305 593 4300 • Date of manufacture, hours of operation, and last maintenance date² www.gesecurity.com • Number of recorded alarms and troubles² © 2006 General Electric Company • Time and date of last alarm¹ All Rights Reserved • Most recent trouble code logged by the detector — 32 possible trouble codes may be used to diagnose faults. Signature Series is a Trademark Automatic Device Mapping –The Signature Data Controller (SDC) learns where each of GE Security. device’s serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or “as-built” drawing informa- tion showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: • Unexpected additional device addresses • Missing device addresses • Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configura- tion and are indicated during device mapping. Standalone Operation – A decentralized alarm decision by the device is guaranteed. On- board intelligence permits the device to operate in ¹EST3 V.2 only. ²Retrievable with SIGA-PRO programming tool. Data Sheet 85001-0239 Issue 7 Not to be used for installation purposes. Page 6 of 6

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the SIGA-CR have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Edwards Signaling & Security Systems SIGA-DH Systems - Intelligent Duct Smoke Detector Housing 85001...

product

Edwards Signaling SIGA-IPHS GE-FIRE Intelligent 4D Multisensor Detector Heat

product

Edwards Signaling & Security Systems SIGAPS Photoelectric Smoke Detector