RED LION CONTROLS CUB4L8W0

Image of RED LION CONTROLS CUB4L8W0

Description

Red Lion Controls CUB4L8W0 COUNTER 8 DIGIT LCD DISPLAY None Required (Battery Included) LCD No Backlight

Part Number

CUB4L8W0

Price

Request Quote

Manufacturer

RED LION CONTROLS

Lead Time

Request Quote

Category

TIMERS, COUNTER & METERS

Features

Datasheet

pdf file

Red Lion Controls CUB4L8W0-datasheet1-297429630.pdf

714 KiB

Extracted Text

Bulletin No. CUB4-C Drawing No. LP0585 Released 12/08 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL CUB4L, CUB4L8 & CUB4L8W - MINIATURE ELECTRONIC COUNTERS ! LCD, POSITIVE REFLECTIVE OR NEGATIVE TRANSMISSIVE WITH YELLOW/GREEN OR RED LED BACKLIGHTING ! INTERNAL LITHIUM BATTERY PROVIDES UP TO 6 YEARS OF UNINTERRUPTED OPERATION ! NEMA 4X/IP65 SEALED FRONT BEZEL ! FRONT PANEL RESET, REMOTE RESET, OR BOTH ! COUNT SPEEDS UP TO 5 KHz (Model Dependent) ! COUNT INPUT FROM 10 to 300 VAC/DC (CUB4L8W) ! WIRE CONNECTION MADE VIA SCREW CLAMP TYPE UL Recognized Component, TERMINALS File # E179259 DESCRIPTION SAFETY SUMMARY The CUB4 offers a large display in a miniature package. There are three All safety related regulations, local codes and instructions that appear in the CUB4 counters to choose from; the CUB4L (6-digit counter), CUB4L8 (8-digit manual or on equipment must be observed to ensure personal safety and to counter), and the CUB4L8W (8-digit counter with voltage input). You also have prevent damage to either the instrument or equipment connected to it. If a choice of three displays; reflective, red backlight or green backlight. equipment is used in a manner not specified by the manufacturer, the protection The backlight versions require power from an external 9–28 VDC supply. The provided by the equipment may be impaired. optional power supply (MLPS1000) is designed to be attached directly to the rear of the CUB4 and is powered from an 85–250 VAC source. The power supply CAUTION: Risk of Danger. provides 12 VDC @ 400 mA to power the backlight and sensor, if required. Read complete instructions prior to The CUB4 series has a lightweight, high impact plastic case with a clear installation and operation of the unit. viewing window. The sealed front panel with the silicone rubber reset button meets NEMA 4X/IP65 specifications for wash-down and/or dusty environments, when properly installed. SPECIFICATIONS 1. DISPLAY: CUB4L: 6-Digit, LCD, 0.48" (12.2 mm) high digits. ORDERING INFORMATION CUB4L8 & CUB4L8W: 8-Digit, LCD, 0.46" (11.7 mm) high digits. MODEL NO. DESCRIPTION PART NUMBERS 2. POWER SOURCE: Internal 3.0 V lithium battery to provide up to 6 years Counter Positive Image Reflective CUB4L000 of continuous operation. Battery life is dependent upon usage. Count and reset Counter w/Yel-Grn Backlighting CUB4L010 CUB4L contacts that remain closed for long periods of time will reduce battery life. (6-digit) 3. BACKLIGHT POWER REQUIREMENTS: 9 to 28 VDC, 35 mA typical, Counter w/Red Backlighting CUB4L020 50 mA max. Above 26 VDC, derate operating temperature to 50°C. Counter Positive Image Reflective w/V+ Terminal CUB4LM00 Must use the MLPS or a Class 2 or SELV rated power supply. Counter Positive Image Reflective CUB4L800 4. INPUTS: Counter w/Yel-Grn Backlighting CUB4L810 CUB4L8 All Inputs: V (low) = 0.5 V max. IL (8-digit) Counter w/Red Backlighting CUB4L820 Low Speed Input (CUB4L & CUB4L8): 30 Hz from switch contact or open collector transistor with a 50% duty cycle. Counter Positive Image Reflective w/V+ Terminal CUB4L80M Low Speed Input (CUB4L8W): 10 to 300 VAC/DC, 50/60 Hz, 30 cps max. Counter Positive Image Reflective CUB4L8W0 V = 0.5 VDC max. Unit counts on positive going edge. Will not operate IL CUB4L8W Counter w/Yel-Grn Backlighting CUB4L8W1 with Triac outputs. (8-digit Counter w/Red Backlighting CUB4L8W2 High Speed Input (CUB4L): 5 KHz from 4.0 V to 28.0 V bipolar output w/VCM) Counter Positive Image Reflective w/V+ Terminal CUB4L8WM with a 50% duty cycle. High Speed Input (CUB4L8): 5 KHz at 2.0 V (3 V max) bipolar output with MLPS Micro Line/Sensor Power Supply MLPS1000 a 50% duty cycle. For more information on Pricing, Enclosures & Panel Mount Kits refer to the RLC Remote Reset: Catalog or contact your local RLC distributor. CUB4L: 15 msec min. pulse width (active low) from 4.0 V to 28.0 V bipolar output or an open collector transistor or a switch contact to common. Note: Recommended minimum clearance (behind the panel) for mounting clip DIMENSIONS In inches (mm) installation is 2.15" (54.6) H x 3.00" (76.2) W. PANEL CUT-OUT 1 CUB4L8 & CUB4L8W: 15 msec min. pulse width (active low) from 3.0 V EMC INSTALLATION GUIDELINES bipolar output or an open collector transistor or a switch contact to Although Red Lion Controls Products are designed with a high degree of common. immunity to Electromagnetic Interference (EMI), proper installation and wiring 5. ENVIRONMENTAL CONDITIONS: methods must be followed to ensure compatibility in each application. The type Operating Temperature: 0 to 60°C (above 50°C, derate backlight operating of the electrical noise, source or coupling method into a unit may be different voltage to 26 VDC max.). for various installations. Cable length, routing, and shield termination are very Storage Temperature: -30 to 85°C important and can mean the difference between a successful or troublesome Operating and Storage Humidity: 85% max. (non-condensing) from 0°C to installation. Listed are some EMI guidelines for a successful installation in an 50°C. industrial environment. Vibration According to IEC 68-2-6: 5 to 500 Hz, in X, Y, Z direction for 1.5 1. Use shielded (screened) cables for all Signal and Control inputs. The shield hours, 5g’s. (screen) pigtail connection should be made as short as possible. The Shock According to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions. connection point for the shield depends somewhat upon the application. Altitude: Up to 2000 meters Listed below are the recommended methods of connecting the shield, in order 6. CERTIFICATIONS AND COMPLIANCES: of their effectiveness. SAFETY a. Connect the shield only at the panel where the unit is mounted to earth UL Recognized Component, File # E179259, UL 61010-1, CSA C22.2 No. ground (protective earth). 61010-1 b. Connect the shield to earth ground at both ends of the cable, usually when Recognized to U.S. and Canadian requirements under the Component the noise source frequency is above 1 MHz. Recognition Program of Underwriters Laboratories, Inc. c. Connect the shield to common of the unit and leave the other end of the Type 4X Enclosure rating (Face only), UL50 shield unconnected and insulated from earth ground. IECEE CB Scheme Test Certificate # US/9257C/UL, 2. Never run Signal or Control cables in the same conduit or raceway with AC CB Scheme Test Report # E179259-V01-S02 power lines, conductors feeding motors, solenoids, SCR controls, and Issued by Underwriters Laboratories, Inc. heaters, etc. The cables should be run in metal conduit that is properly IEC 61010-1, EN 61010-1: Safety requirements for electrical grounded. This is especially useful in applications where cable runs are long equipment for measurement, control, and laboratory use, Part 1. and portable two-way radios are used in close proximity or if the installation IP65 Enclosure rating (Face only), IEC 529 is near a commercial radio transmitter. ELECTROMAGNETIC COMPATIBILITY 3. Signal or Control cables within an enclosure should be routed as far away as Immunity to EN 50082-2 possible from contactors, control relays, transformers, and other noisy Electrostatic discharge EN 61000-4-2 Level 2; 4 Kv contact components. Level 3; 8 Kv air 4. In extremely high EMI environments, the use of external EMI suppression Electromagnetic RF fields EN 61000-4-3 Level 3; 10 V/m devices, such as ferrite suppression cores, is effective. Install them on Signal 80 MHz - 1 GHz and Control cables as close to the unit as possible. Loop the cable through the Fast transients (burst) EN 61000-4-4 Level 4; 2 Kv I/O core several times or use multiple cores on each cable for additional protection. Level 3; 2 Kv power Install line filters on the power input cable to the unit to suppress power line RF conducted interference EN 61000-4-6 Level 3; 10 V/rms interference. Install them near the power entry point of the enclosure. The 150 KHz - 80 MHz following EMI suppression devices (or equivalent) are recommended: Power frequency magnetic fields EN 61000-4-8 Level 4; 30 A/m Ferrite Suppression Cores for signal and control cables: Simulation of cordless telephone ENV 50204 Level 3; 10 V/m Fair-Rite # 0443167251 (RLC #FCOR0000) 900 MHz ± 5 MHz TDK # ZCAT3035-1330A 200 Hz, 50% duty cycle Steward #28B2029-0A0 Emissions to EN 50081-2 Line Filters for input power cables: RF interference EN 55011 Class B Schaffner # FN610-1/07 (RLC #LFIL0000) Schaffner # FN670-1.8/07 Refer to the EMC Installation Guidelines section of this bulletin for Corcom #1VR3 additional information. Note: Reference manufacturer’s instructions when installing a line filter. 7. CONSTRUCTION: 5. Long cable runs are more susceptible to EMI pickup than short cable runs. This unit is rated for NEMA 4X/IP65 indoor use. Installation Category I, Therefore, keep cable runs as short as possible. Pollution Degree 2 8. WEIGHT: 3 oz. (85 grams) INSTALLATION ENVIRONMENT The unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation. Placing the unit near devices that generate excessive heat should be avoided. The bezel should be cleaned only with a soft cloth and neutral soap product. Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the aging process of the bezel. Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the keypad of the unit. Installation The CUB4 series of products meet NEMA 4X/IP65 requirements for indoor use, when properly installed. The units are intended to be mounted into an enclosed panel. The viewing window and reset button are factory sealed for a washdown environment. A sponge rubber gasket and mounting clip are provided for sealing the unit in the panel cut-out. The following procedure assures proper installation: 1. Cut panel opening to specified dimensions. Remove burrs and clean around panel opening. 2. Carefully remove the center section of the panel gasket and discard. Slide gasket over rear of the unit to the back of the bezel. 3. Assemble nut fastener first and then mounting screw onto both sides of mounting clip. Tip of screw should not project from hole in mounting clip. 6. Alternately tighten each screw to ensure uniform gasket pressure. Visually 4. Install CUB4 unit through the panel cut-out until front bezel flange contacts inspect the front panel gasket. The gasket should be compressed about 75 to the panel-mounted gasket. 80% of its original thickness. (Recommended torque is 28 to 36 in-oz.) If 5. Slide the mounting clip over the rear of the unit until the mounting clip is not, gradually turn mounting screws to further compress gasket. against the back of the panel. The mounting clip has latching features which 7. If gasket is not adequately compressed, and mounting screws can no longer engage into mating features on the CUB4 housing. be turned, loosen mounting screws and check that mounting clip is latched Note: It is necessary to hold the unit in place when sliding mounting clip into as close as possible to panel. position. Repeat procedure for tightening mounting screws. 2 WIRING CONNECTIONS The electrical connections are made via rear screw-clamp terminals located on the back of the unit. When wiring the unit, use the label to identify the wire position with the proper function. All conductors should meet voltage and current ratings for each terminal. Also cabling should conform to appropriate standards of good installation, local codes and regulations. It is recommended that power supplied to the unit (AC or DC) be protected by a fuse or circuit breaker. Strip the wire, leaving approximately 1/4" bare wire exposed (stranded wires should be tinned with solder). Insert the wire into the screw-clamp terminal and tighten down the screw until the wire is clamped tightly. Each terminal can accept up to two #14 AWG wires. Note: The Reflective CUB4 will NOT have a screw terminal installed at the V+ terminal, since it is NOT required for operation and is not internally connected. Refer to the Ordering Information for the part number of a Note: This drawing is for CUB4L and CUB4L8 reference only. reflective model that will accommodate the MLPS. For reference of CUB4L8W, refer to Backlight Option on page 4. Backlight Wiring Optional backlight versions of the CUB4 require an external 9-28 VDC Warning: Lithium battery may explode if incinerated. power supply. The external supply is connected between the V+ and Common Caution: All leads will be at the same line potential as the input leads. terminals. CUB4L AND CUB4L8 LOW SPEED COUNT INPUT, 30 Hz MAX. Pulling the “L.S. CNT.” Input to Common with a mechanical or solid-state switch increments the counter. The low pass filter used with a Schmidt trigger circuit debounces mechanical switch signals. The switch load is 14 µA (max. voltage drop 0.5 V) when ON. The OFF-state leakage current must be less than 2 µA. Motor starter contacts, tungsten contacts, and brush-type contacts should NOT be used. CUB4L8W L.S. INPUT, 30 CPS MAX. The CUB4L8W accepts most machine control voltage signals. The input accepts AC (50/60 Hz) or DC control voltages from 10 to 300 V at count speeds up to 30 cps. The unit counts on the positive going edge of the input signal. WARNING: Any lead may be at hazardous live input potential. External wiring and devices connected to the unit must be rated the same as applied signal input voltage and be properly isolated from Class 2 or SELV circuitry. CUB4L HIGH SPEED COUNT INPUT, 5 KHz MAX. The “H.S. CNT.” Input allows the CUB Counter to operate at speeds up to 5 KHz when driven by bi-polar outputs. Input drive voltage must be limited to 28.0 V maximum to avoid damage to the counter. INPUT PULSE EXCURSION LIMITS V (High) = +4.0 V min., +28.0 V max. IH V (Low) = +0.5 V max. IL 3 CUB4L8 HIGH SPEED COUNT INPUT, 5 Hz MAX. TTL OR CMOS PNP O.C. TRANSISTOR NPN O.C. OUTPUT OR BI-POLAR OUTPUT TRANSISTOR FIG 1 FIG 2 FIG 3 The “H.S. CNT.” Input allows the CUB Counter to operate at speeds up to R values for Fig 2 & 3 5 KHz when driven by bi-polar outputs or external circuits having an output INPUT PULSE EXCURSION LIMITS +V R V (High) = 2.0 V min., 3.0 V max. impedance of 3.3 KΩ or less. Input drive voltage must be limited to 3 V IN +5 V 2.2 K maximum to avoid damage to the counter. CMOS and TTL logic outputs can V (Low) = ±0.5 V max. IL +12 V 10 K be loaded with a resistor (Rl) to limit drive voltage, or a voltage divider can +18 V 16 K be used as shown for the PNP O.C. transistor output. +24 V 24 K RESET OPTIONS BACKLIGHT OPTION Connecting a wire from the “RST. EN.” (Reset Enable) Input terminal to Common will enable the front panel Reset button. When Remote Reset is required, a wire is connected from the “REM. RST.” input terminal to Optional backlight versions of the CUB4 require an external 9-28 VDC Common. Pulling this input low causes the counter to reset. The “REM. RST.” power supply. The external supply is connected between the V+ and Common can be pulled low by either a mechanical switch or solid-state transistor terminals as shown in the drawing. switch. Switch load and leakage are the same as for “L.S. CNT.” Input above. Red Lion Controls optional power supply (MLPS1000) is designed to be attached directly to the rear of a CUB4 and is powered from a 85 to 250 VAC Note: The RC protection circuit on the “REM. RST.” Input causes a delay of source. The MLPS provides power for unit backlighting and a sensor. approximately 15 msec in Reset response. WARNING: When connecting the wiring for a backlit CUB4L8W measuring an AC input voltage, the neutral of the single phase AC signal is connected to Terminal 1 (COM), and line (hot) is connected to Terminal 5 (LS). The DC supply for the backlighting is connected as shown in the drawing. Three phase AC applications require an isolation transformer. TROUBLESHOOTING For further technical assistance, contact technical support at the appropriate company numbers listed. Red Lion Controls AP Red Lion Controls Red Lion Controls BV Unit 101, XinAn Plaza 20 Willow Springs Circle Printerweg 10 Building 13, No.99 Tianzhou Road York PA 17406 NL - 3821 AD Amersfoort ShangHai, P.R. China 200223 Tel +1 (717) 767-6511 Tel +31 (0) 334 723 225 Tel +86 21 6113-3688 Fax +1 (717) 764-0839 Fax +31 (0) 334 893 793 Fax +86 21 6113-3683

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the CUB4L8W0 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Red Lion Controls CUB4V000 Voltmeter; Voltmeter Meter Type; 75 VDC; + 0.1% 1 Digit; 1.5 Sec.; 0 to ...

product

Red Lion Controls CUB7P200 HSPEED LOGIC INPUT CNTR POS None Required (Battery Included) LCD No Backl...

product

Red Lion Controls DT90000 5 DIGIT RATE INDIC ADJ .46INCH None Required (Battery Included) LCD No Bac...

product

Red Lion Controls DT900020 RATE INDICATOR ADJ RED BACKLIGHT 9 V ~ 28 V LCD Backlit

product

BEZEL PANEL FOR HWK50000

product

Red Lion Controls MDMU0110MINIATURE DISPLAY MODULE COUNTER/TIMER 6-DIG YEL BKLIT PCB MNT 4.5 V ~ 5.5...