ELAN SRBNARC15

Description
PART
Part Number
SRBNARC15
Price
Request Quote
Manufacturer
ELAN
Lead Time
Request Quote
Category
PRODUCTS - S
Datasheet
Extracted Text
. T R E Z F SRB-NA-R-C.15, ...-C.15/1 Safety relay array for emergency stop devices, interlocking devices and others ☛3 enabling outputs and 1 monitoring output ☛Cross-short recognition Features – Relay output: 3 NO, 1 NC – NC contacts for monitoring – Housing 22.5 mm, made of (Auxiliary NC for monitoring (SRB-NA-R-C.15/1: in series) thermoplastic in accordance with must not be used in Safety (SRB-NA-R-C.15: in parallel) UL-94-V-0, red RAL 3000 Enabling Circuits!) – Input for emergency stop – DIN rail mounting – Reset, feedback loop or door monitoring DIN EN 50 022 – LED’s for K1, K2, U i Approvals Ü (SRB-NA-R-C.15) LR 13571-30 E 54284 (M) 96201 Front view 13 23 33 14 24 34 K2 SRB- UB NA-R -C.15 K1 41 X1 C 42 X2 D Product range Type Enabling outputs Operating voltage Part no. SRB-NA-R-C.15-24VDC 3 NO/1 NC 24 VDC 600 0032 SRB-NA-R-C.15-24VAC 3 NO/1 NC 24 VAC 600 0044 SRB-NA-R-C.15/1-24VDC 3 NO/1 NC 24 VDC 600 0046 SRB-NA-R-C.15/UC 3 NO/1 NC 24 VDC/VAC On request 30 R P - G B SRB-NA-R-C.15, ...-C.15/1 (continued) 2 Example for dual-channel door Wiring diagram L-(A2) L+(A1) L1 monitoring using two limit switches Open (one with positive opening contacts) and Closed external reset button. K B Reset Dual-channel output, suitable for contact **** reinforcement or contact multiplication, K A using relays or contactors with positively X1 X2 13 23 33 41 41 C * guided contacts. **** = Feedback loop F1** Wire breakage and earth leakage in the K2 K1 K1 K2 Monitoring circuits are detected. K K1 A Earth leakage at input D is detected only in mains with insulation leakage monitoring. K K2 B K1 K2 * Monitoring contacts in series at SRB-NA-R-C.15/1 D 14 24 34 42 42 ** Fuse M 0.5 A (an external leading fuse M 0.25 A K K B A is recommended) N For further examples refer to page 32/33 Model specific Operating voltage 24 VDC –15%/+20%, residual ripple max. 10% Technical data 24 VAC –15%/+6% (refer to page 157 Frequency 50/60 Hz (for AC operating) for general data) Fuse (power supply) M 0.25 A/250 V (internal M 0.5 A/250 V) Power consumption max. 2.5 VA Switching capacity (enabling contacts) 230 VAC, 6 A ohmic (inductive with suitable suppression) Fuse (enabling contacts) 6 A slow blowing Switching capacity (monitoring contacts) 24 V, 2 A ohmic (inductive with suitable suppression) Fuse (monitoring contacts) 2 A slow blowing Application category AC 15/DC 13, DIN VDE 0660 Part 200 Pick-up delay ≤ 10 ms Drop-out delay ≤ 30 ms Contact material / contacts AgSnO, self cleaning, positively driven Contact resistance max. 100 mOhm when new Air and creeping distances DIN VDE 0110-1 (04.97), 4 kV/2 Connections Self lifting screw terminals min. 0.6 qmm, max. 2.5 qmm Dimensions H/W/D 82 mm/22.5 mm/98.8 mm Weight 190 g Ambient operating temperature –25 °C ... +45 °C (derating curve page 157) 7 Mechanical life 10 switching cycles Terminal labeling DIN EN 60 445/DIN 40 719 Part 2 31 SRB-NA-R-C.15, ...-C.15/1 (continued) Wiring example: Wiring example: Input level Input level L+(A1) L-(A2) X1 L+(A1) L-(A2) X1 Single-channel emergency Dual-channel emergency stop stop switch according to switch according to EN 60 204-1. EN 60 204-1. Wire breakage and earth Wire breakage and earth leakage in the emergency leakage in the emergency stop Reset Emergency Reset Emergency stop circuits are detected. circuits are detected. switch off switch off With external reset button. Cross-shorts in the emergency stop circuits are detected. Safety category 2 in accordance with With external reset button. EN 954-1. Safety category 3 in accordance with EN 954-1. CX D 2 C D X2 Wiring example: Wiring example: Input level Input level L+(A1) L-(A2) X1 L+(A1) L-(A2) X1 Single-channel door Dual-channel door monitoring according to monitoring according to ON Open EN 1088 limit switch with EN 1088, one limit switch OFF Closed positive opening contact. with positive opening contact. Wire breakage and earth Reset Reset leakage in the door Wire breakage and earth monitoring circuits are leakage in the door detected. monitoring circuits are detected. With external reset button for increased safety Cross-shorts in the requirements. emergency stop circuits are detected. Safety category 2 in accordance with With external reset button EN 954-1. for increased safety requirements. Safety category 3 CX D 2 C DX2 in accordance with EN 954-1. 32 SRB-NA-R-C.15, ...-C.15/1 (continued) 2 Wiring example: Wiring example: Power level Power level Single-channel output. Dual-channel output. L1 L1 L1 L1 Suitable for contact Suitable for contact * * * * reinforcement or contact KA KA KB KB reinforcement or contact KA KA KB KB multiplication, using relays multiplication, using relays X1 X1 X2 X2 13 13 X1 X1 X2 X2 13 13 23 23 or contactors with or contactors with KA KA positively guided contacts. positively guided contacts. KB KB 14 14 14 14 24 24 KB KB KA KA KA KA KB KB KA KA KB KB N N N N * Reset button wired in * Reset button wired in series to feedback loop. series to feedback loop. 33
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the SRBNARC15 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods