BARBER COLMAN MF2-PID
Specifications
Controller
MICROFLO II VAV Controller
Datasheet
Barber Colman-MF2-PID-MICROFLO II-datasheet1-150637615.pdf
376 KiB
Extracted Text
MF2 Series ™ MICROFLO II Product Family The Invensys MICROFLO II family of direct digital controllers (DDC) is compatible with pressure independent and pressure dependent variable air volume terminal box applications. The MICROFLO II controllers operate in a stand-alone mode providing accurate zone temperature control and can be integrated into a facility-wide BAS/DDC system by utilizing the I/A Series family of controllers. Invensys Building Systems provides an integrated Building Automation System capable of meeting the tough control strategies of today’s VAV Air Systems. The MICROFLO II family of controllers may be applied to new VAV terminals or retrofitted to existing electric, electronic or pneumatic actuated air terminals. Standard sequence for morning warmup using primary air when Models of the MICROFLO II family support standard butterfly used with a heat/cool VAV AHU. damper terminal boxes, pneumatic terminal boxes and boxes with existing integral actuators. In addition, the MICROFLO II family of Reheat options are integral to controller for application to all controllers provides compatibility with all types of terminal box and types of terminal box and perimeter reheat. radiation reheat, along with integrated zone lighting control, Optional local pushbutton override at wall sensor provides timed helping to make the MICROFLO II family the most comprehensive override of unoccupied conditions and enables start up of line of DDC VAV terminal box controllers available in today's central system and zone lighting. market. Local space setpoint provides occupants with traditional control of their own comfort settings. Features — High accuracy wall and duct sensors allow startup and damage • Built-in applications with adjustable options provide compatibility replacement without recalibration. with the wide variety of terminal boxes available in today’s Up to four controllers may be controlled in parallel from one market. sensor and setpoint for homogenous control of zones served by Direct digital control (DDC) eliminates long-term recalibration multiple VAV air terminals. maintenance cost. Through the use of extensive onboard software diagnostics, Integral packaging combines actuator, transducer and controller troubleshooting time is minimized. into one attractive and highly functional package to increase Facility-wide monitoring, alarming, load shed control, Global reliability and reduce maintenance costs. Control Strategies, and information management are available Personal System Interface provides the user with the industry’s through the I/A Series family of DDC controllers. most advanced and easiest to use hand-held interface. Building managers have the option of remote override of Personal System Interface terminal jack option at wall sensor occupant settings to improve energy and operating efficiency. provides VAV box setup, adjustment of controller functions, and Occupied/unoccupied mode changeover is compatible with a simple “Air Balancing.” local time clock or globally through the I/A Series. Flexible device configurations allow spare or unused output points to be used for control of local lighting, motorized shades, or other applications external to the terminal box. Invensys Building Systems, Inc. Direct digital control algorithms allow selection of proportional or 1354 Clifford Avenue proportional-integral control independently for the cooling and P.O. Box 2940 Loves Park, IL 61132-2940 heating sections. www.invensysibs.com Printed in U.S.A. 5-04 © Copyright 2004 Invensys Building Systems, Inc. All rights reserved. F-24314-2 Tenant utility cost allocation are available when MICROFLO II is Velocity Pressure Input integrated with the I/A Series BAS. Operating Range -0.20 to 2.10 in. of W.C. (-0.05 to +0.523 kPa). Maintenance scheduling on terminal units is easily implemented Control Range 0.01 to +2.00 in. of W.C. (0.0025 to when integrated with the I/A Series BAS. +0.497 kPa). Through the I/A Series Universal Network Controller, the Accuracy ± 5% V.P. ±0.005 in. W.C. (0.07 to +2.00 in. of MICROFLO II controller is fully configurable, allowing automatic W.C.). Laminar flow at 25 °C. downloading and uploading of controller configuration. Sensor Type Flow sensor (differential pressure). Tubing Connection Barb fittings for 1/4" O.D. FRPE Table-1 Model Chart. polyethylene tubing or 1/8" I.D. tygon tubing (high and low pressure taps). Model Description Tubing Length 5 feet maximum each tube (Static Pressure feet maximum). Pressure Independent, Cooling only, with internal MF2-PIC Inputs actuator Space Temperature 40 to 95 °F (4 to 35 °C). Pressure Independent, Deluxe (4 DO, 1 AO), with MF2-PID internal actuator Local Setpoint 55 to 85 °F or 10 to 30 °C. Auxiliary Air Temperature 40 to 140 °F (4 to 60 °C). Pressure Independent/Dependent, Deluxe (4 DO, MF2-PIT Contact Status Input For stand-alone occupancy control or 1 AO), with Triacs for external actuator drive remote status monitoring of local status condition (dry contact). Pressure Independent/Dependent, Deluxe (4 DO, Momentary Pushbutton Override (optional) At wall sensor. MF2-PIP 1 AO), with analog output for pneumatic primary Cooling Throttling Range Adjustable 1 to 15 °F. actuator through I/P transducer Heating Throttling Range Adjustable 1 to 15 °F. Integral Actuator Model Outputs (-PIC, -PID) Hardware Specifications Damper Linkage 1/2" or 3/8" round shaft extending 3/4" min. Dimensions 6.75 in. H x 8 in. W x 4 in. D from terminal box (3/8” round shaft requires AM-135 adaptor (171 mm x 203 mm x 102 mm). kit). Torque Rating 30 lb-in. (3.4 N-m). Enclosure Conforms to NEMA-1. Meets UL 94-5V flammability ratings for plenum application use. Timing 3 minutes for 90° rotation under continuous drive. Damper Control Conduit Knockouts 7 knockouts for 1/2" conduit provided. Minimum Flow/Position Setting Adjustable Flow (CFM) Power Supply Input 20 to 30 Vac, 50/60 Hz. or 0 to 100%. Maximum Power Consumption 40 VA for MF2-PIT, 20 VA for all Maximum Flow/Position Setting Adjustable Flow (CFM) other models. or 0 to 100%. Agency Approvals Mechanical Travel Limit Adjustable 90 to 45° (factory set for 90°). UL-873 File #E9429 Category XAPX. External Actuator Model Outputs (-PIT, -PIP) CSA File #LR 3728. FCC Part 15 Class B. -PIT Triac outputs (2) rated @ 24 Vac, 0.75 A to drive external bi-directional synchronous motor. UL-864 File #S5381 Category UUKL. -PIP 4-20 mAdc into a 200 to 500 Ω load impedance for Transient Compliance Tests (ANSI C62.41) IEEE-587, interface to I/P transducer or electronic analog actuator. Category A,B. Analog Outputs (-PID, -PIT, -PIP) Electrostatic Discharge Test ±15 kV to case, ±5 kV to field wiring terminals. Quantity -PID, -PIT 1. Ambient Limits -PIP 2 (1 for Primary Damper Operation). Temperatures Type 4-20 mA, into a 200 to 500 Ω load impedance for Operating 40 to 140 °F (4 to 60 °C). interface to modulating hydronic valves, fan speed controller Shipping and Storage -40 to 160 °F (-40 to 71 °C). and pneumatic I/P transducer. Humidity 5 to 95% non-condensing. Digital Outputs (-PID, -PIT, -PIP) Microprocessor 83C196. Quantity 4. Memory 8 KB of ROM, 1 KB of EEPROM. Contact Ratings 28.8 VA @ 24 Vac or 144 VA @ 120 Vac, Form A (SPST-N.O.) pilot duty relays for control of fan starters, Diagnostic Display LED indication of operational status. electric heat, modulating actuator, lights and other loads. Wiring Terminals Screw terminals accepting 14 to 24 AWG wire. Use copper conductors only. 2 © Copyright 2004 Invensys Building Systems, Inc. All rights reserved. F-24314-2 Software Specifications Sensor Models Control Functions Refer to Table-2. TSMN-57011-850 Wall sensor TSMN-90220-850 Wall sensor with PSI communications jack Table-2 MICROFLO II Control Strategies, Pressure Independent or Pressure Dependent. TSMN-90230-850 Wall sensor with PSI communications jack, and push button override Box Configuration Reheat Type TSMN-90250-850 Wall sensor with PSI communications jack, Cooling Staged Electric push button override, and remote setpoint (55 Series Fan Time Proportional Electric to 85 °F) Parallel Fan Floating (Modulating) Induction Proportional Hydronic TSMN-90250-852 Wall sensor with communications jack, push Static Pressure Proportional Hydronic button override, and remote setpoint (10 to Double Duct (PI/PD) Staged Leading Proportional 30 °C) Proportional Leading Staged Proportional Leading TS-5721-854 Duct probe Proportional Personal System Interface Communications LAPT-80800 Personal System Interface software ASD Bus RS-485 at 19,200 baud. (See F-24317) Personal System Interface RS-485, 19,200 baud. Plug into RJ-12 jack at wall sensor location. Communications supported to Accessories all ASD devices within network. Permits reconfiguration, monitoring, air balance, and editing of all MICROFLO II AD-8969-206 11 kΩ shunt resistor for use with TS-57XXX configuration data. sensors AM-135 3/8” to 1/2” shaft adaptor PC-301 Air flow switch (for Electric Reheat Flow Interlock) F-24314-2 © Copyright 2004 Invensys Building Systems, Inc. All rights reserved. 3 MZ2 MZ2 MF2 MF2 RXTXON ASD ADDRESS U-Bus 12 12 ASD BU–S12 + SHLD24H24G GND RXTXON ASD ADDRESS U-Bus 12 12 ASDB U–S12 +SHLD 242H4G GND Internet Remote GCM-8XX21 Browser User WorkPlace Pro Interface LCM Bus ASD Bus Ethernet, TCP/IP, BACnet, XML, HTTP ® MICROZONE II UNC-510 Local Control PEM ASD Bus, RS-485 Modules ™ Communications Bus (LCM ) I/A Series Enterprise Server MICROFLO II™ MICROZONE II Web Browser LIM™ PEM ™ MicroNet 2000 Integrator MICROFLO II LIM MicroNet 2000 Integrator Figure-1 MICROFLO II with Other ASD Devices in the I/A Series System. © Copyright 2004 Invensys Building Systems, Inc. All rights reserved. Invensys, I/A Series, and MICROFLO II are trademarks of Invensys plc and its subsidiaries and No part of this document may be photocopied or reproduced by any means, or translated to affiliates. another language without prior written consent of Invensys. All other trademarks are the property of their respective owners. All specifications are nominal and may change as design improvements are introduced. Invensys shall not be liable for damages resulting from misapplication or misuse of its products. F-24314-2 Printed in U.S.A.
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the MF2-PID have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods