Elite.Parts chervon right Manufacturers chervon right S chervon right SEALEVEL SYSTEMS chervon right 3095
About product Features Datasheet FAQ

SEALEVEL SYSTEMS 3095

Image of SEALEVEL SYSTEMS 3095

Description

REL-16 ISA 16 Reed Relay Output Digital Interface

Part Number

3095

Price

Request Quote

Manufacturer

SEALEVEL SYSTEMS

Lead Time

Request Quote

Category

PRODUCTS - 3

Features

Datasheet

pdf file

3095.pdf

68 KiB

Extracted Text

™ REL-16 USER’S MANUAL Part Number 3095 Sealevel Systems, Inc Phone: (864) 843-4343 155 Technology Place Fax: (864) 843-3067 P.O. Box 830 www.sealevel.com Liberty, SC 29657 Contents INTRODUCTION ...............................................................................1 OVERVIEW .................................................................................................... 1 WHAT’S INCLUDED ...................................................................................... 1 FACTORY DEFAULT SETTINGS ...................................................................... 1 CARD SETUP ....................................................................................2 ADDRESS SELECTION .................................................................................... 2 INSTALLATION.................................................................................3 SOFTWARE INSTALLATION........................................................................... 3 For Windows Users................................................................................ 3 TECHNICAL DESCRIPTION .............................................................4 FEATURES .................................................................................................... 4 OUTPUT PORTS (REED RELAY) .................................................................... 5 RELAY SPECIFICATIONS................................................................................ 5 Output Ports (Reed Relay) Pin Assignments (P2) .............................. 6 PROGRAMMING ..............................................................................7 APPLICATION PROGRAMMERS INTERFACE (API).......................................... 7 Relative Addressing vs. Absolute Addressing...................................... 7 DIRECT HARDWARE CONTROL..................................................................... 9 Reading the Outputs (relays) (direct) : ................................................. 9 Writing the Outputs (relays) (direct) : ................................................. 9 SPECIFICATIONS ...........................................................................10 ENVIRONMENTAL SPECIFICATIONS.............................................................10 POWER CONSUMPTION...............................................................................10 MEAN TIME BETWEEN FAILURES (MTBF).................................................10 PHYSICAL DIMENSIONS..............................................................................10 APPENDIX A - TROUBLESHOOTING ............................................11 APPENDIX B - HOW TO GET ASSISTANCE...................................12 APPENDIX C - SILK-SCREEN........................................................13 APPENDIX D - SCHEMATIC ..........................................................14 APPENDIX E - COMPLIANCE NOTICES........................................16 FEDERAL COMMUNICATIONS COMMISSION STATEMENT ...........................16 EMC DIRECTIVE STATEMENT....................................................................16 WARRANTY....................................................................................17 Figures Figure 1 - Address Selection Table.................................................................... 2 Figure 2 - DIP-Switch Illustration.................................................................... 2 ©2002a Sealevel Systems, Incorporated. All rights reserved. Introduction Introduction Overview The REL-16 provides 16 reed relays that can latch power, data or other electronic signals for control applications. The REL-16 is PC compatible and fits any half length ISA or EISA slot. Addressing, data and control signals are TTL compatible. The REL-16 is simple to operate. By writing instruction bytes to the I/O port addresses, the reed relays are energized or de-energized. What’s Included The REL-16 is shipped with the following items. If any of these items are missing or damaged, contact the supplier. · REL-16 Interface Adapter · Relay/Digital I/O Software · User manual Factory Default Settings The REL-16 factory default settings are as follows: Base Address IRQ 300 5 To install the REL-16 using factory default settings, refer to Installation on page 3. For your reference, record installed REL-16 settings below: Base Address IRQ Sealevel Systems REL-16 Page 1 Installation Card Setup The REL-16 contains several jumper straps for each port which must be set for proper operation. Address Selection The REL-16 occupies a total of 2 I/O locations. The DIP-switch (SW1) is used to set the base address for these locations. Be careful when selecting the base address as some selections conflict with existing PC ports. The following table shows several examples that usually do not cause a conflict. Address Binary Switch Settings 1 2 3 4 5 6 7 8 100-104 01 0000 00xx Off On On On On On On On 104-108 01 0000 01xx Off On On On On On On Off 200-204 10 0000 00xx On Off On On On On On On 280-283 10 1000 00xx Off On Off On On On On On 284-287 10 1000 01xx Off On Off On Off On On Off 2EC-2EF 10 1110 11xx Off On Off Off Off On Off Off 300-303 11 0000 00xx Off Off On On On On On On 320-323 11 0010 00xx Off Off On On Off On On On 388-38B 11 1000 10xx Off Off Off On On On Off On 3A0-3A3 11 1010 00xx Off Off Off On Off On On On 3A4-3A7 11 1010 01xx Off Off Off On Off On On Off Figure 1 - Address Selection Table The following illustration shows the correlation between the DIP-switch setting and the address bits used to determine the base address. In the example below, address 302 is selected as the base address. Address 302 in binary is XX 11 0000 00XX where X = a non-selectable address bit and address bit A9 is always a 1. A9 A2 ON OFF 1 2 3 4 5 6 7 8 Figure 2 - DIP-Switch Illustration Note: Setting the switch ‘On’ or ‘Closed’ corresponds to a ‘0’ in the address, while leaving it ‘Off’ or ‘Open’ corresponds to a ‘1’. Sealevel Systems REL-16 Page 2 Installation Installation The REL-16 can be installed in any ISA PC expansion slot. The REL-16 contains a DIP-switch (SW1) which must be set prior to installation. 1. Turn off PC power. Disconnect the power cord. 2. Remove the PC case cover. 3. Locate an two available slots and remove the blank metal slot covers. 4. Gently insert the REL-16 into the slot. Make sure the adapter is seated properly. 5. Replace the cover. 6. Connect the power cord. Installation is complete. Software Installation For Windows Users Choose Install Software at the beginning of the CD and select the Digital I/O software drivers and install SeaIO. Sealevel Systems REL-16 Page 3 Technical Description Technical Description The REL-16 provides two output (I/O) ports. The ports are organized as ports A and B and are reed relay output ports. Assuming an I/O address of 302 Hex the following table shows the Port Addresses. Base Address Hex Decimal Mode 300 768 Unused 301 769 Unused Port A Address 302 770 Output Port (Reed Relays) Port B Address 303 771 Output Port Please note that ports A and B are output ports with read-back capability, meaning that they can be written (output) to and then read back as inputs. What ever was written will always be read back (binary complement). This allows for bits to be set or reset without altering the state of the other port bits. Features · Selectable I/O port addressing from 100H - 3FFH · 2 sets SPST relays with each set having 8 relays · DB-37 male connector for relay outputs · Highly reliable 10 VA DIP reed relays utilized · 8 bit slot connector · Multiple adapters can reside in same computer · All address, data and control signals are TTL compatible Sealevel Systems REL-16 Page 4 Technical Description Output Ports (Reed Relay) The output ports on the REL-16 relay output are connected to 16 dip reed relays. Reed relays provide very high quality, long life, low current (10 watt maximum), dry contact switch closures. Reed relays are not suited for high current applications, and can be destroyed by inductive load switching, where a spark occurs across the contacts internally. The relays are normally open, and close when energized. Each relay can be individually energized by writing a "1" to the proper port bit. Relay Specifications · Contact Power Ratings: 10 Watts Maximum · Contact Voltage Maximum: 100 Volts DC or AC Maximum · Contact Current Maximum: .5 Amps DC or AC RMS · Contact Resistance, Initial: .15 Ohms · Rated Life: Low Load: 200 Million Closures Maximum Load: 100 Million Closures · Contact Speed: Operate: .5 m Sec Release: .5 m Sec Bounce: .5 m Sec · Maximum Operating Speed: 600 Hertz Sealevel Systems REL-16 Page 5 Technical Description Output Ports (Reed Relay) Pin Assignments (P2) Port C Relay P2 Pin Port D Relay P2 Pin Bit Bit 0 K16 2,20 0 K8 10,28 1 K15 3,21 1 K7 11,29 2 K14 4,22 2 K6 12,30 3 K13 5,23 3 K5 13,31 4 K12 6,24 4 K4 14,32 5 K11 7,25 5 K3 15,33 6 K10 8,26 6 K2 16,34 7 K9 9,27 7 K1 17,35 Ground 18,36,37 + 5 Volts 19 + 12 Volts 1 Sealevel Systems REL-16 Page 6 Technical Description Programming Application Programmers Interface (API) Most modern operating systems do not allow direct hardware access. The SeaIO driver and API have been included to provide control over the hardware in Windows and Linux environments. The purpose of this section of the manual is to help the customer with the mapping of the API to the actual relays for the 3095 specifically. Complete documentation of the API can be found in its accompanying help file. Relative Addressing vs. Absolute Addressing The SeaIO API makes a distinction between “absolute” and “relative” addressing modes. In absolute addressing mode, the Port argument to the API function acts as a simple byte offset from the base I/O address of the device. For instance, Port #0 refers to the I/O address base + 0; Port #1 refers to the I/O address base + 1. Relative addressing mode, on the other hand, refers to input and output ports in a logical fashion. With a Port argument of 0 and an API function meant to th output data, the first (0 ) output port on the device will be utilized. Likewise, with a Port argument of 0 and an API function designed to input data, the first th (0 ) input port of the device will be utilized. In all addressing modes, port numbers are zero-indexed; that is, the first port is port #0, the second port is #1, the third #2, and so on. Sealevel Systems REL-16 Page 7 Technical Description Tables : API Port/bit reference numbers for Absolute and Relative Addressing R = Read W = Write R/W = Read or Write Port API Port # Absolute API Port # Port Type Address (function) Relative Address (function) 0 Unused 1 Unused A 2 ( R/W ) 0 ( W ) Output Port (Reed Relays) B 3 ( R/W ) 1 ( W ) Output Port API Bit # Absolute API Bit # Relative Port Bit Address (function) Address (function) 16 ( R/W ) 0 ( W ) A0 17 ( R/W ) 1 ( W ) A1 18 ( R/W ) 2 ( W ) A2 19 ( R/W ) 3 ( W ) A3 20 ( R/W ) 4 ( W ) A4 21 ( R/W ) 5 ( W ) A5 22 ( R/W ) 6 ( W ) A6 23 ( R/W ) 7 ( W ) A7 24 ( R/W ) 8 ( W ) B0 25 ( R/W ) 9 ( W ) B1 26 ( R/W ) 10 ( W ) B2 27 ( R/W ) 11 ( W ) B3 28 ( R/W ) 12 ( W ) B4 29 ( R/W ) 13 ( W ) B5 30 ( R/W ) 14 ( W ) B6 31 ( R/W ) 15 ( W ) B7 Sealevel Systems REL-16 Page 8 Technical Description Direct Hardware Control In systems where the users program has direct access to the hardware (DOS) the table below gives the mapping and functions that the 3095 provides, a base address of 300 was used. If a different base address is used then the port addresses are calculated as shown in the table. Reading the Outputs (relays) (direct) : The relay ports return the ones complement of the value that is currently being used to drive the relays. When using the API the value is returned not the complement of the value. Writing the Outputs (relays) (direct) : The output ports are the only ports that can be written. The relays on a standard 3095 are normally open. To close a relay a one must be written to the appropriate bit. R = Read W = Write R/W = Read or Write Function Port Address Hex Address Port Type Available Decimal 300 (Base + 0) 768 Unused 301(Base + 1) 769 Unused R/W A 302 (Base + 2) 770 Output Port (Reed Relays) R/W B 303 (Base + 3) 771 Output Port Sealevel Systems REL-16 Page 9 Specifications Specifications Environmental Specifications Specification Operating Storage Temperature 0º to 50º C -20º to 70º C Range (32º to 122º F ) (-4º to 158º F) Humidity Range 10 to 90% R.H. 10 to 90% R.H. Non-Condensing Non-Condensing Power Consumption Supply line +12 VDC +5 VDC Rating 50 mA 800 mA Mean Time Between Failures (MTBF) Greater than 150,000 hours. (Calculated) Physical Dimensions Board length 4.9 inches (12.45 cm) Board Height including Goldfingers 4.2 inches (10.66 cm) Board Height excluding Goldfingers 3.9 inches (9.906 cm) Note: Please see Appendix D for board layout and dimensions. Sealevel Systems REL-16 Page 10 Appendix A - Troubleshooting Appendix A - Troubleshooting 1. Identify all I/O adapters currently installed in your system. This includes your on-board serial ports, controller cards, sound cards etc. 2. Configure your Sealevel Systems adapter so that there is no conflict with currently installed adapters. No two adapters can occupy the same I/O address. 3. Make sure the Sealevel Systems adapter is securely installed in a motherboard slot. 4. The following are known I/O conflicts: · The 278 and 378 settings may conflict with your printer I/O adapter. · 3B0 cannot be used if a Monochrome adapter is installed. · 3F8-3FF is typically reserved for COM1: · 2F8-2FF is typically reserved for COM2: · 3E8-3EF is typically reserved for COM3: · 2E8-2EF is typically reserved for COM4: Sealevel Systems REL-16 Page 11 Appendix B - How To Get Assistance Appendix B - How To Get Assistance Please refer to Appendix A - Troubleshooting prior to calling Technical Support. 1. Read this manual thoroughly before attempting to install the adapter in your system. 2. When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics. 3. Technical support is available Monday to Friday from 8:00 a.m. to 5:00 p.m. Eastern time. Technical support can be reached at (864) 843-4343. RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER. Sealevel Systems REL-16 Page 12 Appendix C - Silk-Screen Appendix C - Silk-Screen Sealevel Systems REL-16 Page 13 Appendix D - Schematic Appendix D - Schematic Sealevel Systems REL-16 Page 14 Appendix D - Schematic Sealevel Systems REL-16 Page 15 Appendix E - Compliance Notices Appendix E - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in such case the user will be required to correct the interference at his own expense. EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive (89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the European Commission. To obey these directives, the following European standards must be met: • EN55022 Class A - “Limits and methods of measurement of radio interference characteristics of information technology equipment” • EN55024-‘Information technology equipment Immunity characteristics Limits and methods of measurement. • EN60950 (IEC950) - “Safety of information technology equipment, including electrical business equipment” Warning This is a Class A Product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives. Sealevel Systems REL-16 Page 16 Warranty Warranty Sealevel Systems, Inc. provides a lifetime warranty for this product. Should this product fail to be in good working order at any time during this period, Sealevel Systems will, at it's option, replace or repair it at no additional charge except as set forth in the following terms. This warranty does not apply to products damaged by misuse, modifications, accident or disaster. Sealevel Systems assumes no liability for any damages, lost profits, lost savings or any other incidental or consequential damage resulting from the use, misuse of, or inability to use this product. Sealevel Systems will not be liable for any claim made by any other related party. RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER. Sealevel Systems, Incorporated 155 Technology Place P.O. Box 830 Liberty, SC 29657 USA (864) 843-4343 FAX: (864) 843-3067 www.sealevel.com email: support@sealevel.com Technical Support is available from 8 a.m. to 5 p.m. Eastern time. Monday - Friday Trademarks Sealevel Systems, Incorporated acknowledges that all trademarks referenced in this manual are the service mark, trademark, or registered trademark of the respective company. REL-16 is a trademark of Sealevel Systems, Incorporated. Sealevel Systems REL-16 Page 17

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 3095 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

DIO-32B ISA 16 Reed Relay Output/16 Isolated Input Digital Interface

product

ISO-16 ISA 16 Optically Isolated Input Digital Interface

product

DIO-16 ISA 8 Reed Relay Output/8 Isolated Input Digital Interface

product

REL-32 ISA 32 Switched Relay Output Digital Interface

product

C4-104.ULTRA PC/104 RS-232, RS-422, RS-485 (Software Selectable) Serial Interface

product

PC/104 RS-232, RS-422, RS-485 Serial Interface