SCHMERSAL AZR31T2
Specifications
Coil Resistance
150ohm
Coil Voltage VDC Nom
24V
Contact Configuration
DPNC
Contact Current AC Max
2.5A
Contact Current DC Max
3A
Contact Current Max
6.2A
Contact Voltage AC Max
400V
Contact Voltage AC Nom
400V
Contact Voltage DC Max
24V
Contact Voltage DC Nom
24V
External Depth
73.2mm
External Height
73.2mm
External Length/Height
73.2mm
External Width
45mm
Mounting Type
DIN Rail
No. of Poles
2
Operating Temperature Max
50°C
Operating Temperature Min
0°C
Relay Mounting
DIN Rail
Supply Voltage
24VDC
SVHC
No SVHC (19-Dec-2011)
Switching Capacity
1Hz
Features
- 1 auxiliary contact (NC)
- 2 NC contacts can be connected
- 3 enabling circuits
- 4 LED’s to show operating conditions
- Additional contacts by means of output expansion
- Automatic reset function
- Can be used as emergency-stop controller for stop Category 0 to EN 60204-1
- Control Category 4 to EN 954-1
- Cross-wire monitoring
- Feedback circuit to monitor external contactors
- magnet sensors, switching mats or E-stops
- Monitoring of mechanical position switches, safety switches, solenoid interlocks, coded
- Removable terminal block
- Start-stop function
Datasheet
Extracted Text
CC4 Guard Door and E-Stop Safety Controllers Safety Category (EN954-1): Stop Category (EN60204-1): AZR 31 T2 to Monitor One Device 0 Features • Control Category 4 to EN 954-1 • 3 enabling circuits • Monitoring of mechanical position switches, safety switches, solenoid interlocks, coded magnet sensors, switching mats or E-stops • 2 NC contacts can be connected • Can be used as emergency-stop controller for stop Category 0 to EN 60204-1 • 1 auxiliary contact (NC) • Cross-wire monitoring • Automatic reset function • Removable terminal block • Start-stop function • Feedback circuit to monitor external contactors • 4 LED’s to show operating conditions • Additional contacts by means of output expansion Dimensions 45 x 73.2 x 121 mm Model AZR 31 T2-24VDC Designation AZR 31 T2-24VAC AZR 31 T2-110VAC AZR 31 T2-230VAC Approvals BG UL CSA 60 Guard Door and E-Stop Safety Controllers AZR 31 T2 to Monitor One Device Typical Application L1 Typical L+ Wiring L1 Diagram 0 0 A1 S13 S24 X1 41 13 23 33 AZR31T2 K1 S L1 L3 L2 K2 A2 S14 S23 X2 42 14 24 34 K3 K4 L- N N M 3 C SC K4 4 Notes • NC contacts must have positive • The wiring diagram is with guard opening function when the guard devices closed and shows the de- device is opened. energized condition, whereby the normally closed contacts connect- • The feedback circuit monitors the ed must be closed. positions of the positive-drive NC contacts on the contactors K3 and K4. If the feedback circuit is not needed, a jumper connection is to be fitted between the inputs X1 and X2. Circuit • Start Pushbutton s Options A start pushbutton (NO) can option- ally be connected to the inputs X1 and X2. With the guard device(s) closed, the enabling circuits are then not closed until the start push- button has been operated. If neither start button nor feedback circuit are connected, a jumper must be wired between X1 and X2. 61 Guard Door and E-Stop Safety Controllers AZR 31 T2 to Monitor One Device Typical Application Typical L1 L+ Wiring L1 Diagram 0 0 A1 S13 S24 X1 41 13 23 33 K1 S L1 L3 L2 AZR31T2 K2 A2 S14 S23 X2 42 14 24 34 L- N N M 3 SK4 CC4 0 Notes • The safety controller fulfills • AZR safety controller being used Category 0 to EN 60 204-1. to monitor an emergency-stop. • Secures to Control Category 4 to • The diagram is shown for the EN 954-1. de-energized condition. Circuit • Start Pushbutton s A start pushbutton can optionally Option be connected between the termi- nals X1 and X2. If no start pushbut- ton is used, a jumper must be wired between X1 and X2. 62 Guard Door and E-Stop Safety Controllers AZR 31 T2 to Monitor One Device Typical Application Typical L+ Wiring L1 Diagram L1 A1 S13 S24 X1 41 13 23 33 K1 L1 L2 L3 K2 A2 S14 S23 X2 42 14 24 34 R L- N N M C SC K1 1 3 0 Notes • The safety controller fulfills stop • AZR safety controller being used • The diagram is shown for the Category 0 to EN 60 204-1. to monitor two emergency-stop de-energized condition. switches (A and B), two ZS pull- • The arrangement shown in the wire switches (C and D) and a wiring diagram serves to achieve safety switch of the AZ 16 range Control Category 1 to EN 954-1. with separate actuator (E) as well as a power contactor. 63 Safety Controllers for Special Applications Monitoring Safety Switching Mats Using AZR 31 T2 Typical Application Typical Wiring Diagram CC3 Notes • To achieve Control Category 3 to • Monitoring a safety switching • The wiring diagram shows the EN 954-1 mat and power contactors using de-energized condition. the AZR safety controller with automatic reset. 64
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the AZR31T2 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods