Elite.Parts chervon right Manufacturers chervon right E chervon right EXTREME NETWORKS chervon right 10G4Xc
About product Specifications Features Datasheet FAQ

EXTREME NETWORKS 10G4Xc

Image of EXTREME NETWORKS 10G4Xc

Description

Extreme Networks 10G4Xc I/O Module - 4 XFP 10GBASE-X Ports, High density PoE switch, for converged enterprise edge, Scalable 10G or GE switch, for small, medium or large enterprise cores

Part Number

10G4Xc

Price

Request Quote

Manufacturer

EXTREME NETWORKS

Lead Time

Request Quote

Category

TBD

Specifications

10GBASE-X Ports

4 XFP

ACL Hardware Resources

4k ACLs per 2-port block

Backplane capacity (Gbps) 2 MSM/1 MSM

48/24

IP Multicast (S,G,V)

2k

IPv4 Host Table

6k

IPv4 Longest Prefix Match (LPM) Entries

12k

IPv6 Forwarding

Hardware

Layer 2 MAC FDB

32k

Load Sharing Groups

128

sFlow Sampling

Hardware

Features

Datasheet

pdf file

Extreme Networks=BlackDiamond8800series=Datashee-434072508t.pdf

1843 KiB

Extracted Text

Extreme Networks Data Sheet BlackDiamond 8800 Series Switches with 8500/8800/8900 Series Modules Enterprise IT managers and service providers have limited time BlackDiamond® 8800 series switches simplify enterprise, data or resources to deal with overly complex, specialized network center and service provider networks. infrastructure solutions. BlackDiamond 8800 series switches from Extreme Networks® simplify the architecture. Purpose- High Availability built core, aggregation, edge and data center/service provider modules can meet your chassis needs across the network. • Redundant system design BlackDiamond 8800 series switches deliver voice-class • Modular ExtremeXOS® Operating System (OS) for availability, high-density Power over Ethernet (PoE), Gigabit non-stop operation Ethernet (GbE), and 10 GbE wherever it’s needed. • Ethernet Automatic Protection Switching (EAPS) resiliency protocol With three families of modules to choose from, the BlackDiamond 8800 series switches can support a wide variety of applications. In enterprise and data center networks, High-Performance Connectivity and traditional three-tier architectures can be replaced with a Low Power Consumption streamlined two-tier network that helps reduce management • High-density gigabit, 10 Gigabit and 40 Gigabit overhead, operational complexity and capital expenditures. It Ethernet switch serves well as a high-performance Enterprise core and Data Center switch. The ports interconnect thousands of servers for • Large switching capacity capable of supporting High Performance Cluster Computing (HPCC). 2,840 Mpps • Convergence-ready connectivity with Voice-over-IP The BlackDiamond 8800 series switches with 8900-xl series (VoIP) automatic provisioning modules meet the needs of next generation service provider transport networks for converged services and are ideal for • Flexible connectivity options for multiple applications deployment at the metro core and mobile backhaul aggrega- • Low power consumption for reduced power and tion hub. BlackDiamond 8900-xm 40 Gigabit modules meet cooling costs the needs of next-generation data centers and service • Tunable Dense Wavelength Division Multiplexing (DWDM) providers. A full range of Layer 2 - 4 features for IPv4 and IPv6 for reduced fiber run counts allow the aggregation of high-speed connections, minimizing bottlenecks between edge and core. BlackDiamond 8800 fits well at the edge of the most demanding enterprises, with Comprehensive Security Voice-over-IP, video, wireless and data traffic. The multifaceted • Universal Port dynamic security profile to provide BlackDiamond 8800 series switches support IPv6 today, fine-grained security policies preparing the enterprise for the future. • Threat detection and response instrumentation to react to network intrusion with CLEAR-Flow Security Rules Engine Target Applications • Hardened network infrastructure • High-performance core switch for medium to large enterprise networks • Scalable and resilient switch for metro core and mobile backhaul cell site aggregation hub • High-density switch providing low-latency connections at low power for data centers and HPCC • Cost-effective wiring closet/edge switch for small to medium enterprises Make Your Network Mobile Extreme Networks Data Sheet: BlackDiamond 8800 Series High Availability A high-performance network connection, whether used to connect PCs and IP telephones at the access layer or to interconnect servers in a cluster, is only useful if it is also highly available. BlackDiamond 8800 series modular switch- ing family incorporates extensive hardware redundancy and a modular OS—ExtremeXOS—that provides the network recovery required by converged applications. protected from each other. This drives increased system Redundant System Design integrity and inherently protects against Denial of Service Redundant Management Modules (DoS) attacks. The BlackDiamond 8800 series of modular switches are Process Monitoring and Restart configured with an automatic failover mechanism so that if one Management Switch Module (MSM) fails, the second MSM will ExtremeXOS dramatically increases network availability using automatically take over management responsibility for the process monitoring and restart. Each independent OS process entire switch. This feature is critical for networks running voice is monitored in real time. If a process becomes unresponsive or and other mission-critical applications. (This capability is not stops running, it can be automatically restarted. available for the BlackDiamond 8500-series modules.) Loadable Software Modules Advanced Chassis Design for Availability The modular design of ExtremeXOS allows the upgrading of individual software modules, should this be necessary, leading BlackDiamond 8800 series switches include a passive back- to higher availability in the network (see Figure 1). plane complemented by high availability design elements such as isolated control and data planes, redundant controller boards for power distribution, and fan control and High Availability Network Protocols environmental monitoring to identify anomalies before they Ethernet Automatic Protection Switching affect network availability. (EAPS) EAPS allows the IP network to provide the level of resiliency and Redundant Load Sharing Power Supplies uptime that users expect from their traditional voice networks. BlackDiamond 8800 series switches support a set of redundant EAPS is more adaptable than Spanning Tree or Rapid Spanning power configurations that can load share up to six internal Tree Protocols, offering sub-second (less than 50 milliseconds) power supplies simultaneously. Three power supplies in a 2 + 1 recovery and delivering consistent failover regardless of number redundancy configuration can power a fully loaded chassis with of VLANs, number of network nodes or network topology. In gigabit or 10 Gigabit Ethernet ports. In addition, without the most situations, VoIP calls will not drop and digital video feeds need of an external power tray, three power supplies are will not freeze or pixelize because EAPS allows the network to available to support large PoE implementations. recover almost transparently from link failure. Redundant Cooling Fans in a Hot-Swappable Spanning Tree/Rapid Spanning Tree Fan Tray Protocols Redundant cooling is delivered by a tray of nine fans BlackDiamond 8800 series switches support Spanning Tree (BlackDiamond 8810) or six fans (BlackDiamond 8806). The fan (802.1D), Per VLAN Spanning Tree (PVST+), Rapid Spanning tray itself is hot swappable so the BlackDiamond 8800 series Tree (802.1w) and Multiple Instances of Spanning Tree (802.1s) switches keep operating while the fan tray is replaced. protocols for Layer 2 resiliency. Modular Operating System for Software Enhanced Availability Non-Stop Operations Software enhanced availability allows users to remain con- nected to the network even if part of the network infrastructure Preemptive Multitasking and Protected is down. BlackDiamond 8800 series switches constantly check Memory for problems in the uplink connections using advanced Layer 3 BlackDiamond 8800 series switches allow each of many protocols such as OSPF, VRRP and Extreme Standby Router protocols such as Open Shortest Path First (OSPF) and Protocol™ (ESRP, supported in Layer 2 or Layer 3), and Spanning Tree to run as separate OS processes that are dynamically route around the problem. 2 Extreme Networks Data Sheet: BlackDiamond 8800 Series High Availability Equal Cost Multipath Routing Multi-Switch Link Aggregation Groups (M-LAG) Equal Cost Multipath (ECMP) routing enables uplinks to be load M-LAG can address bandwidth limitations and improve balanced for performance and cost savings while also support- network resiliency, in part by routing network traffic around ing redundant failover. If an uplink fails, traffic is automatically bottlenecks, reducing the risks of a single point of failure, and routed to the remaining uplinks and connectivity is maintained. allowing load balancing across multiple switches. Link Aggregation (802.3ad) Cross-module link aggregation enables trunking of up to eight links on a single logical connection, for up to 80 Gbps of redundant bandwidth per logical connection. 1 3 • Processes are monitored Memory protected Designed to allow and can be restarted or processes under application other action taken if real-time modules to be necessary SSH-2 scheduling that upgraded during V1.3.2 cannot impact runtime • Hitless failover each other nor infrastructure for dual kernel management systems and stacking 2 Application Third modules can be SSH-2 Party BGP OSPF added during V1.3.1 Application runtime ExtremeXOS Kernel Loadable Kernel Module 5027-04 Figure 1: ExtremeXOS Modular Design 3 Extreme Networks Data Sheet: BlackDiamond 8800 Series High-Performance Connectivity BlackDiamond 8800 series switches deliver high-performance, cost-effective connectivity to address networking trends such as the increasing number of devices at the edge of the network: IP telephones, wireless Access Points (APs), and other devices. These networking trends drive the requirement for Gigabit Ethernet to the desktop and the use of 10 Gigabit Ethernet as an interconnect technology. single 14RU chassis or can power a maximum of 432 PoE ports Large Switching Capacity in a single chassis with Class 1 or 2 power. No external power BlackDiamond 8800 series switches deliver 3.8 Tbps of trays are needed in order to power up fully loaded switching bandwidth, and over 2,840 Mpps Layer 2 – Layer 3 BlackDiamond 8800 series switches with Class 1, 2 or 3 devices. hardware forwarding rate. Link Layer Discovery Protocol (LLDP) • 256 Gbps per slot bidirectional bandwidth Support • Local switching on every I/O module BlackDiamond 8800 series switches incorporate LLDP to High-Density, Line-Rate Connectivity simplify troubleshooting of enterprise networks and enhance BlackDiamond 8800 series switches support up to 2,352 the ability of network management tools to discover and gigabit ports or up to 582 10 Gigabit Ethernet ports in a single maintain accurate network topologies. seven-foot rack, allowing BlackDiamond 8800 series switches to deliver cost-effective connectivity for a range of edge, Universal Port—Voice-over-IP (VoIP) Auto aggregation, core and data center needs. Provisioning BlackDiamond 8800 series switches set the stage for conver- Jumbo Frame Support gence applications by allowing enterprises to add new access Supporting jumbo frames allows cluster computing applica- devices in a non-disruptive plug-and-play fashion. Voice and tions to optimize network performance. wireless services can be easily implemented without major network upgrades. BlackDiamond 8800 series switches IPv6 Packet Forwarding Support support automatic provisioning of VoIP using LLDP and IPv6 makes available trillions of new IP addresses and offers event-based command scripting capability. It allows dynamic better address allocation, address aggregation, and features configuration of voice VLANs and QoS. This auto-configuration that provide significantly greater end-to-end connectivity and capability allows you to configure VoIP phone settings such as services. BlackDiamond 8800 series switches support IPv6 voice VLAN settings, call server IP address configuration, etc. today, and enable enterprises to get ready to handle IPv6 This level of simplicity in managing network changes can help traffic as this traffic enters their networks. reduce operating expenses. Convergence-Ready Connectivity Flexible Connectivity with VoIP Automatic Provisioning The BlackDiamond 8800 series switches support virtualization, specifically virtual routing and dynamic movement of Voice-Grade Connections virtual servers. BlackDiamond 8800 series switches support 8 queues per port and a range of QoS technologies that can prioritize and Support for Virtualized Data Centers predictably handle high-priority traffic policing or rate-limiting Direct Attach™ eliminates switching at the virtual switch layer, on ingress, 802.1q tagging and DiffServ marking, and shaping simplifying the network and improving performance. Direct on egress. The Extreme Networks tradition of building products Attach enables data center simplification by reducing network with low latency and jitter continues with BlackDiamond 8800 tiers from 4 or 5 tiers to just 3 or 2 tiers, depending on the size series switches, allowing network managers to build high- of the data center. (Requires the Direct Attach Feature Pack, performance networks. part number 11011.) High-Density PoE PoE allows BlackDiamond 8800 series switches to support large IP Telephony and wireless AP deployments. BlackDiamond 8810 can support up to 333 Class 3 ports in a 4 Extreme Networks Data Sheet: BlackDiamond 8800 Series High-Performance Connectivity XNV™ (ExtremeXOS Network Virtualization) is a set of software Ease of Management modules for the ExtremeXOS® based switching product Extreme Networks has developed tools that save you time and portfolio, and is available via the Data Center Feature Pack for resources in managing your network. The Universal Port Extreme Networks Ridgeline™, a network and service manage- capability allows auto-configuration of VoIP phones, for ment application. XNV brings insight, control and automation example, providing simplicity in managing network changes. for highly virtualized data centers to the network. Ridgeline network and service management provides fault, Priority-based Flow Control (PFC, or IEEE 802.1Qbb) allows configuration, accounting, performance and security functions, network traffic to be controlled independently based on Class allowing more effective management of Extreme Networks of Service. PFC allows network traffic that requires lossless products, solutions and third-party devices, in a converged traffic throughput to be prioritized, while other traffic types network. that do not require or perform better without PFC can continue For carrier networks, Ridgeline enables the shift from reactive as normal. (Requires 8900-10G24X-c I/O module(s), part circuit monitoring to proactive service management. The key number 41632B.) features integrated into the Service Advisor Feature Pack unify service fulfillment, service assurance and service engineering to Support for Service Provider Metro enable carriers to more effectively manage next-generation Core and Mobile Backhaul residential triple play, business Ethernet and Ethernet mobile Applications backhaul services. The BlackDiamond 8800 series with 8900-xl or -xm series Investment Protection modules offers up to 198 line-rate 10 GbE ports, 1,200 GbE ports (fiber or copper), or 48 40 GbE ports in a seven-foot rack, With a wide range of available I/O and management modules, providing outstanding services capacity. High port density and the versatile BlackDiamond 8800 series switches provide resiliency through EAPS makes this series an ideal core or superior investment protection over the product lifetime. For aggregation solution for next-generation packet transport example, the BlackDiamond 8500-series modules can support networks. Whether deployed as a metro core switch or at the wiring closet or small enterprise edge applications; at a later cell-site aggregation hub for mobile backhaul, these switches date, BlackDiamond 8800 c-series modules can be implemented provide high-performance converged services over a single to support medium-sized enterprise core deployment or transport network—including residential triple-play, business aggregation. And the BlackDiamond 8900-series modules, Ethernet and mobile voice and data services. A single transport with their high performance and high density, can support network provides cost savings by eliminating the need for large enterprises or interconnection for data centers and HPCC multiple overlay networks.The switches support IEEE 802.1ag applications. Past and current generations of modules are Continuity Fault Management for proactive service manage- compatible with any BlackDiamond 8800 series chassis. ment, and hardware support for multicast quality of service. Tunable DWDM support allows service providers and others to tune XFP 10 Gigabit Ethernet optics to a specific frequency, reducing the need for additional fiber runs and XFP sparing. Digital Diagnostics Monitoring Interface (DDMI) support allows service providers to monitor and diagnose pluggable optics in real-time. Low Power Consumption The BlackDiamond 8800 series switches typically consume 1.5 Watts (2.1 Watts maximum) per Gigabit Ethernet port and 7.0 Watts (10.4 Watts maximum) per 10 Gigabit Ethernet port. This is significantly lower than other switches in the industry, and can provide considerable savings in power and cooling costs. 5 Extreme Networks Data Sheet: BlackDiamond 8800 Series High-Performance Connectivity 8500-Series Connectivity 8900-Series Modules 8800 c-Series Modules Modules 8900- 8900- 8900- 8900- 8900- 8900- 8500- 8500- I/O Module Name G24Xc G48Te2 G48Tc G48Xc 10G4Xc 10G8Xc 40G6X-xm 10G8X-xl G48X-xl G48T-xl G96T-c 10G24X-c G24X-e G48T-e ACL Hardware 4k 60k ACLs 60k ACLs 60k ACLs 8k ACLs 2k ACLs 4k ACLs 1k ACLs per 4k ACLs 4k ACLs 4k ACLs 4k ACLs 1k ACLs 1k ACLs Resources per 48-port per 12-port per 24-port 24-port per 24-port per 24-port per 2-port per 2-port per 24-port per 24-port block block block block block block block block block block Policy Based Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Routing ® sFlow Sampling Yes Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware IPFIX Yes Yes Yes Yes Yes No No No No No No No No No CLEAR-Flow Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes No No 10/100/1000 / / / 48 96 / / 48 48 / / / / 48 BASE-T Ports PoE / / / S-PoE Card / / / S-PoE Card S-PoE Card / / / / S-PoE Card 1000BASE-X / / 48 / / 24 SFP 24 SFP / / 48 SFP / / 48 SFP / Ports 10GBASE-X Ports 24 (using breakout cables 8 XFP / / / 24 SFP+ / / / / 4 XFP 8 XFP / / with 40GBASE- SR4 optics 40GBASE-X Ports 6 / / / / / / / / / / / / / Backplane 160/80 128/64 128/64 128/64 128/64 128/64 capacity (Gbps) 2 [BlackDiamond [BlackDiamond [BlackDiamond [BlackDiamond [BlackDiamond MSM/1 MSM 8806] 8806] 8806] 8806] 8806] 48/24 48/24 48/24 48/24 48/24 48/24 24 24 80/40 80/40 80/40 80/40 80/40 [BlackDiamond [BlackDiamond [BlackDiamond [BlackDiamond [BlackDiamond 8810] 8810] 8810] 8810] 8810] Load Sharing 128 128 128 128 128 128 128 128 128 128 128 128 128 128 Groups Layer 2 MAC FDB 128k 512k 512k 512k 32k 32k 32k 8k 32k 32k 32k 32k 8k 8k IPv4 Longest Prefix Match 16k 512k 512k 512k 12k 12K 12K 480 12K 12K 12K 12K 480 480 (LPM) Entries IPv4 Host Table 6k 16k 16k 16k 8k 8k 6k 1k 6k 6k 6k 6k 1k 1k Extended IPv4 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Host Cache IP Multicast 3k 6k 6k 6k 6k 6k 2k 1k 2k 2k 2k 2k 1k 1k (S,G,V) IPv6 Forwarding Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Hardware Figure 2: Connectivity Options by I/O Module Target 8500-Series 8900-Series Modules 8800 c-Series Modules Modules Applications 8900- 8900- 8900- 8900- 8900- 8900- 8500- 8500- I/O Module Name G24Xc G48Te2 G48Tc G48Xc 10G4Xc 10G8Xc 40G6X-xm 10G8X-xl G48X-xl G48T-xl G96T-c 10G24X-c G24X-e G48T-e High-Performance √ √ √ √ √ √ √ √ √ Enterprise Core Enterprise Data Centers √ √ √ √ √ √ √ √ √ √ √ Traditional Aggregation √ √ √ √ √ √ √ √ √ Layer High-Density Gigabit √ √ √ √ Edge High Performance √ √ √ √ √ √ √ √ Cluster Computing Metro Core √ √ √ √ Mobile Ethernet √ √ √ √ Backhaul Figure 3: I/O Module by Application 6 Extreme Networks Data Sheet: BlackDiamond 8800 Series High-Performance Connectivity 8900-MSM128 8800-MSM-48c 8500-MSM24 CPU 700MHz Dual Core 700MHz Dual Core 700MHz Single Core DRAM 1GB ECC SDRAM 1GB ECC SDRAM 512MB ECC SDRAM Flash 512MB Compact Flash 512MB Compact Flash 512MB Compact Flash Slot Capacity with Up to 160Gbps for BlackDiamond 8806 Up to 48Gbps for BlackDiamond 8806 Up to 48Gbps for BlackDiamond 8806 two MSMs installed Up to 80Gbps for BlackDiamond 8810 and BlackDiamond 8810 and BlackDiamond 8810 MSM Failover Hitless Failover Hitless Failover Automatic Failover CLEAR-Flow Yes Gigabit Uplink Optional 8-port 1G SFP (S-G8Xc) 10 Gigabit Uplink Optional 1-port 10G XFP (S-10G1Xc) Optional 2-port 10G SFP+ (S-10G2Xc) Figure 4: MSM Module Options Recommended Module Deployment 8900-xl/xm series modules 8900-series modules 8500-series modules 8800 c-series modules Small Large Network Size 5255-04 Figure 5: Recommended Module Deployment 7 Performance Extreme Networks Data Sheet: BlackDiamond 8800 Series Comprehensive Security Management Implementing a secure network means providing protection at the network perimeter as well as the core. BlackDiamond 8800 series switches use advanced security functions in protecting your network from known or potential threats. Directory-Integrated Link Security Threat Detection and Response Network Login and Dynamic Security Profile CLEAR-Flow Security Rules Engine Network Login capability implemented in ExtremeXOS enforces CLEAR-Flow Security Rules Engine provides first order threat user admission and usage policies. BlackDiamond 8800 series detection and mitigation, and mirrors traffic to third-party switches support a comprehensive range of Network Login security appliances such as an IDS/IPS for further analysis of options by providing an 802.1x agent-based approach, a suspicious traffic in the network. CLEAR-Flow provides Web-based (agentless) login capability for guests and a cost-effective scalability of security threat detection. MAC-based authentication model for devices. With these modes sFlow of Network Login, only authorized users and devices can connect to the network and be assigned to the appropriate sFlow® is a sampling technology that provides the ability to VLAN. The Universal Port scripting framework available in sample application-level traffic flows on all interfaces BlackDiamond 8800 series switches lets you implement simultaneously. Dynamic Security Profiles which, in sync with Network Login, IPFIX Hardware Support allows you to implement fine grained and robust security policies. Upon authentication, the switch can load dynamic ACL/ IPFIX (Internet Protocol Flow Information eXport) is a comple- QoS profiles for a user or group of users, to deny/allow access to mentary protocol to sFlow. IPFIX gathers information about the application servers or segments within the network. network flows through the switch and sends the information to an external collector. Selected 8900-series I/O modules for Multiple Supplicant Support BlackDiamond 8800 series switches include hardware support Converged network designs often involve the use of shared to keep track of the flow records. See product specifications for ports for IP Telephony and wireless access. Multiple supplicant more information. capability on a switch delivers secured access in such designs by uniquely authenticating and applying appropriate policies Port Mirroring and VLANs for each user on a shared port. BlackDiamond 8800 series switches support many-to-one and cross module port mirroring. This capability can be used to Host Integrity Checking mirror traffic to an external network appliance such as an Host integrity checking helps keep infected or noncompliant intrusion detection device for trend analysis or be utilized by a machines off the network. BlackDiamond 8800 series switches network administrator as a diagnostic tool when fending off a support a host integrity or endpoint integrity solution that is network attack. based on the model from the Trusted Computing Group. Line-Rate Access Control Lists Identity Manager BlackDiamond 8800 series switches support hardware-based Identity Manager allows network managers to track users who ACLs based on Layer 2, 3 or 4 header information such as access their network. User identity is captured based on the MAC address, IP source/destination address or TCP/UDP NetLogin authentication, LLDP discovery and Kerberos port number. snooping. ExtremeXOS uses the information to then report on the MAC, VLAN, computer hostname, and port location of the Hardened Network Infrastructure user. Further, Identity Manager can create both roles and policies, and then bind them together to create role-based Denial of Service (DoS) Protection profiles based on organizational structure or other logical BlackDiamond 8800 series switches handle DoS attacks groupings, and apply them across multiple users to allow gracefully. If the switch detects an unusually large number of appropriate access to network resources. packets in the CPU input queue, it will assemble ACLs that automatically stop these packets from reaching the CPU. After a period of time, the ACLs are removed. If the attack continues, they are reinstalled. 8 Extreme Networks Data Sheet: BlackDiamond 8800 Series Comprehensive Security Management Policy-Based Routing Secure Management Policy-based routing provides a flexible mechanism for network The use of protocols like SSH2, SCP and SNMPv3 supported by administrators to customize the flow of traffic within their a BlackDiamond 8800 series switch prevents the interception networks. ACLs configured on the switch can redirect packets of management communications and man-in-the-middle away from their normal path to another physical switch port. attacks. Packets are selected according to their ACL match conditions MD5 Authentication of Routing Protocols such as QoS, VLAN, IP addresses, protocol, port number or other criteria. MD5 authentication of routing protocols prevents attackers from tampering with valid messages and attacking routing ASIC-Based Longest Prefix Match sessions. LPM routing eliminates the need for control plane software to learn new flows and allows the network to be resilient under a DoS attack. 9 Extreme Networks Data Sheet: BlackDiamond 8800 Series Target Applications 8500-Series Modules Network High-Density PoE Edge Switch for Core the Wiring Closet BlackDiamond 8800 series switches deliver high-performance and cost-effective connectivity to address networking trends such as the increas- ® BlackDiamond 8810 with 8500-series modules BlackDiamond 8806 ing number of IP telephones, wireless APs and other devices at the edge of the network, Gigabit Ethernet connections to the desktop and the use of gigabit and 10 Gigabit Ethernet as an intercon- nect technology. BlackDiamond 8800 series switches allow the traditional edge layer and aggregation layer of the network to be collapsed 5031-05 into a single unified access layer. 8800 c-Series Modules Single Switch Medium-Sized Network BlackDiamond 8800 series switches provide the ® BlackDiamond 8810 with 8800 c-series modules small to medium enterprise with an ideal single- switch solution that satisfies their networking needs. The typical multi-switch network can be consolidated into a single highly available switch that delivers high-density PoE for IP Telephony, high speed performance for services and compre- hensive security. 5033-05 Traditional Aggregation Layer While Extreme Networks believes that a two-tier Network network is a simpler approach, the layout of a Core building or campus or the wiring plant sometimes requires an aggregation layer. This layer typically ® BlackDiamond 8810 BlackDiamond 8810 aggregates gigabit or 10 gigabit uplinks from with with 8800 c-series modules 8800 c-series modules edge switches and connects up to the core through gigabit and/or 10 Gigabit Ethernet uplinks. BlackDiamond 8800 series switches ® Summit Summit Summit Summit provide high-density gigabit and 10 Gigabit 5034-05 Ethernet that is required for the aggregation layer. 10 U * *U 1G-@ H 2 AABBCC DMEF NO3 4PQR IS 5TUV WXYZ6 7 8+| +|9 0 # @ ABC D F 14-GHI 25ABC MENO36 7PQRS 8TUV WXYZ9 0+| #+| Extreme Networks Data Sheet: BlackDiamond 8800 Series Target Applications 8900-Series Modules High-Performance Enterprise Core BlackDiamond 8800 series switches provide the BlackDiamond 8810 BlackDiamond 8810 with 8900-series with 8900-series ideal core network for a medium-sized network modules modules with high-performance and high density 10 Gigabit Ethernet and Gigabit Ethernet interfaces. Customers can connect up to 192 10 gigabit ® Summit Summit Summit Summit ports or 768 gigabit ports in a single 14RU 5052-04 BlackDiamond 8810 system. Enterprise Data Centers High-performance 1 gigabit and 10 gigabit- Network connectivity at low latency and low power Core consumption make the BlackDiamond 8800 series ® a winning switching platform for data centers. The BlackDiamond 8810 BlackDiamond 8810 with 8900-series with 8900-series modules high-density allows 768 wire-speed Gigabit modules Ethernet ports in a single 14RU chassis at typically 1.5 Watts per port and 192 10 Gigabit Ethernet ports at typically 7.0 Watts per port. This allows customers to save on power and cooling costs while providing the superior switching perfor- mance required in the data center. To meet the 5051-04 needs of virtualized data centers, the BlackDiamond 8900-xl series modules can support as many as 512k virtual servers. Service Provider Metro Core and Mobile Backhaul Networks The BlackDiamond 8800 series Ethernet Transport switches with 8900-xl and -xm series Residential Business Mobile Triple-Play Enterprise Backhaul modules are ideal for high-density metro core supporting residential triple-play and business BlackDiamond® 8810 with BlackDiamond 8810 with Ethernet (including E-Line and E-LAN services) 8900-XL series modules 8900-XL series modules and cell site aggregation hub for mobile backhaul deployments. These switches provide high port density, gigabit, 10 GbE or 40 GbE with up to 320 Gbps bidirectional bandwidth capacity per slot. ® Summit Summit Summit E4G Residential Business Mobile Backhaul 5617-01 11 Extreme Networks Data Sheet: BlackDiamond 8800 Series Technical Specifications • RFC 1757 RMON 4 groups: Stats, History, • IP Security – Trusted DHCP Server ExtremeXOS 12.5 Alarms and Events • Layer 2/3/4 Access Control Lists (ACLs) Supported Protocols • RFC 2021 RMON2 (probe configuration) • RFC 2267 Network Ingress Filtering • RFC 2613 SMON MIB • RPF (Unicast Reverse Path Forwarding) • RFC 2925 Ping/Traceroute MIB Control via ACLs Switching • RFC 2668 802.3 MAU MIB • Wire-speed ACLs • RFC 3619 Ethernet Automatic Protection • draft-ietf-hubmib-mau-mib-v3-02.txt • Rate Limiting/Shaping by ACLs Switching (EAPS) and EAPSv2 • RFC 1643 Ethernet MIB • IP Broadcast Forwarding Control • IEEE 802.1D – 1998 Spanning Tree Protocol • RFC 1493 Bridge MIB • ICMP and IP-Option Response Control (STP) • RFC 2096 IPv4 Forwarding Table MIB • SYN attack protection • IEEE 802.1D – 2004 Spanning Tree Protocol • RFC 2737 Entity MIB v2 • CPU DoS Protection with traffic rate-limiting (STP and RSTP) • RFC 2233 Interface MIB to management CPU • IEEE 802.1w – 2001 Rapid Reconfiguration • RFC 3621 PoE-MIB (PoE switches only) • Robust against common network attacks: for STP, RSTP • IEEE 802.1ag MIB – CERT (http://www.cert.org) • IEEE 802.1Q – 2003 (formerly IEEE 802.1s) • Secure Shell (SSH-2) client and server – CA-2003-04: “SQL Slammer” Multiple Instances of STP, MSTP – CA-2002-36: “SSHredder” • Secure Copy (SCP-2) client and server • EMISTP, Extreme Multiple Instances of • Secure FTP (SFTP) server – CA-2002-03: SNMP vulnerabilities Spanning Tree Protocol – CA-98-13: tcp-denial-of-service • sFlow version 5 • PVST+, Per VLAN STP (802.1Q interoperable) • RFC 3917 IPFIX (with 8900-10G8X-xl, – CA-98.01: smurf • Draft-ietf-bridge-rstpmib-03.txt – Definitions 8900-G48T-xl, 8900-G48X-xl, or – CA-97.28:Teardrop_Land -Teardrop and of Managed Objects for Bridges with Rapid 8900-G96T-c modules only) “LAND“ attack Spanning Tree Protocol • Configuration logging – CA-96.26: ping • Extreme Standby Router Protocol™ (ESRP) • Multiple Images, Multiple Configs – CA-96.21: tcp_syn_flooding • IEEE 802.1Q – 1998 Virtual Bridged Local • RFC 3164 BSD Syslog Protocol with Multiple – CA-96.01: UDP_service_denial Area Networks Syslog Servers – CA-95.01: IP_Spoofing_Attacks_and_ • IEEE 802.3ad Static load sharing configura- – 999 Local Messages (criticals stored Hijacked_ Terminal_Connections tion and LACP based dynamic configuration across reboots) – IP Options Attack • Software Redundant Ports • Extreme Networks vendor MIBs (includes • Host Attack Protection • Multi-switch Link Aggregation Groups FDB, PoE, CPU, Memory MIBs) – Teardrop, boink, opentear, jolt2, newtear, (M-LAG) • XML APIs over Telnet/SSH and HTTP/HTTPS nestea, syndrop, smurf, fraggle, papas- • IEEE 802.1AB – LLDP Link Layer • Web-based device management interface – murf, synk4, raped, winfreeze, ping –f, Discovery Protocol ExtremeXOS ScreenPlay™ ping of death, pepsi5, Latierra, Winnuke, • LLDP Media Endpoint Discovery (LLDP-MED), • IP Route Compression Simping, Sping, Ascend, Stream, Land, ANSI/TIA-1057, draft 08 • SFF-8472 DDMI (Digital Diagnostics Octopus • Extreme Discovery Protocol (EDP) Monitoring Interface) • Extreme Loop Recovery Protocol (ELRP) Security, Router Protection • Extreme Link State Monitoring (ELSM) Security, Switch and Network • IP Security – DHCP enforcement via Disable • IEEE 802.1ag L2 Ping and traceroute, ARP Learning Protection Connectivity Fault Management • IP Security – Gratuitous ARP Protection • ITU-T Y.1731 Frame delay measurements • Secure Shell (SSH-2), Secure Copy (SCP-2) • IP Security – DHCP Secured ARP/ARP and SFTP client/server with encryption/ Validation Management and Traffic authentication (requires export controlled • Routing protocol MD5 authentication encryption module) Analysis • SNMPv3 user based security, with • RFC 2030 SNTP, Simple Network Time Security Detection and encryption/authentication (see above) Protocol v4 Protection • RFC 1492 TACACS+ • RFC 854 Telnet client and server • RFC 2138 RADIUS Authentication • CLEAR-Flow, threshold-based alerts and • RFC 783 TFTP Protocol (revision 2) • RFC 2139 RADIUS Accounting actions (In 8800- and 8900-series modules • RFC 951, 1542 BootP • RFC 3579 RADIUS EAP support for 802.1x only) • RFC 2131 BOOTP/DHCP relay agent and • RADIUS Per-command Authentication • Identity Manager DHCP server • Access Profiles on All Routing Protocols • RFC 1591 DNS (client operation) • Access Policies for Telnet/SSH-2/SCP-2 IPv4 Host Services • RFC 1155 Structure of Management • Network Login – 802.1x, Web and • RFC 1122 Host Requirements Information (SMIv1) MAC-based mechanisms • RFC 768 UDP • RFC 1157 SNMPv1 • IEEE 802.1x – 2001 Port-Based Network • RFC 791 IP • RFC 1212, RFC 1213, RFC 1215 MIB-II, Access Control for Network Login • RFC 792 ICMP Ethernet-Like MIB & TRAPs • Multiple supplicants with multiple VLANs • RFC 793 TCP • RFC 1573 Evolution of Interface for Network Login (all modes) • RFC 826 ARP • RFC 1650 Ethernet-Like MIB (update of • Fallback to local authentication database • RFC 894 IP over Ethernet RFC 1213 for SNMPv2) (MAC and Web-based methods) • RFC 1027 Proxy ARP • RFC 1901, 1905 – 1908 SNMPv2c, SMIv2 and • Guest VLAN for 802.1x • RFC 2068 HTTP server Revised MIB-II • RFC 1866 HTML – used for Web-based • IGMP v1/v2/v3 Snooping with Configurable • RFC 2576 Coexistence between SNMP Network Login and ExtremeXOS ScreenPlay Router Registration Forwarding Version 1, Version 2 and Version 3 • SSL/TLS transport – used for Web-based • IGMP Filters • RFC 2578 – 2580 SMIv2 (update to Network Login and ExtremeXOS ScreenPlay • PIM Snooping RFC 1902 – 1903) (requires export controlled encryption • Static IGMP Membership • RFC 3410 – 3415 SNMPv3, user based module) • Multicast VLAN Registration (MVR) security, encryption and authentication • MAC Security – Lockdown and Limit • RFC 3826 – The Advanced Encryption • IP Security – RFC 3046 DHCP Option 82 Standard (AES) Cipher Algorithm in the with port and VLAN ID SNMP User-based Security Model 12 Extreme Networks Data Sheet: BlackDiamond 8800 Series Technical Specifications IPv4 Router Services IPv6 Router Services QoS and VLAN Services • RFC 1812 Requirements for IP Version 4 • RFC 2462, IPv6 Stateless Address Auto Quality of Service and Policies Routers Configuration – Router Requirements • IEEE 802.1D – 1998 (802.1p) Packet Priority • RFC 1519 CIDR • RFC 1981, Path MTU Discovery for IPv6, • RFC 2474 DiffServ Precedence, including • RFC 1256 IPv4 ICMP Router Discovery (IRDP) August 1996 – Router Requirements 8 queues/port • Static Unicast Routes • RFC 2710, IPv6 Multicast Listener Discovery • RFC 2598 DiffServ Expedited Forwarding (EF) • Static Multicast Routes v1 (MLDv1) Protocol • RFC 2597 DiffServ Assured Forwarding (AF) • RFC 1058 RIP v1 • Static Unicast routes for IPv6 • RFC 2475 DiffServ Core and Edge • RFC 2453 RIP v2 • RFC 2080, RIPng Router Functions • Static ECMP • RFC 2740 OSPF v3 (Edge-mode) • RFC 1112 IGMP v1 • Static ECMP Traffic Engineering • RFC 2236 IGMP v2 • RFC 3784 IS-IS Externs for Traffic Engineering • RFC 3376 IGMP v3 Core Protocols for Layer 2, (wide metrics only) • RFC 2933 IGMP MIB IPv4 and IPv6 • RFC 2096 IPv4 Forwarding Table MIB VLAN Services: VLANs, vMANs Requires Core License • RFC 1724 RIPv2 MIB • IEEE 802.1Q VLAN Tagging • EAPSv2 Shared Ports – multiple intercon- • RFC 3768 VRRPv2 • IEEE 802.1v: VLAN classification by Protocol nections between rings • RFC 2787 VRRP MIB and Port • PIM-DM Draft IETF PIM Dense Mode • RFC 2328 OSPF v2 (Edge-mode) • Port-based VLANs draft-ietf-idmr-pim-dm-05.txt, draft-ietf- • OSPF ECMP • Protocol-based VLANs pim-dm-new-v2-04.txt • OSPF MD5 Authentication • MAC-based VLANs • RFC 3618 Multicast Source Discovery • RFC 1587 OSPF NSSA Option • Multiple STP domains per VLAN Protocol (MSDP) • RFC 1765 OSPF Database Overflow • Upstream Forwarding Only/Disable Flooding • RFC 3446 Anycast RP using PIM and MSDP • RFC 2370 OSPF Opaque LSA Option • RFC 5517 Private VLANs • RFC 2740 OSPFv3, OSPF for IPv6 • RFC 3623 OSPF Graceful Restart • VLAN Translation • RFC 1771 Border Gateway Protocol 4 • RFC 1850 OSPFv2 MIB • IEEE 802.1ad Provider Bridge Network, • RFC 1965 Autonomous System Confederations • RFC 2362 PIM-SM (Edge-mode) virtual MANs (vMANs) for BGP • RFC 2934 PIM MIB • vMAN Ethertype Translation/Secondary • RFC 2796 BGP Route Reflection (supersedes • RFC 3569, draft-ietf-ssm-arch-06.txt vMAN Ethertype RFC 1966) PIM-SSM PIM Source Specific Multicast • Multicast Support for PVLAN • RFC 1997 BGP Communities Attribute • draft-ietf-pim-mib-v2-o1.tx • Multicast Support for VLAN Aggregation • RFC 1745 BGP4/IDRP for IP-OSPF Interaction • Mtrace, a “traceroute” facility for IP • VLAN Aggregation • RFC 2385 TCP MD5 Authentication for Multicast: draft-ietf-idmr-traceroute-ipm-07 BGPv4 • Mrinfo, the multicast router information tool MPLS and VPN Services • RFC 2439 BGP Route Flap Damping based on Appendix-B of draft-ietf-idmr- • RFC 2918 Route Refresh Capability for Multi-Protocol Label Switching (MPLS) dvmrp-v3-11 BGP-4 Requires MPLS Feature Pack License, MSM128 and • RFC 3392 Capabilities Advertisement with IPv6 Host Services 8900-10G8X-xl, 8900-G48X-xl, 8900-G48T-xl, or BGP-4 8900-G40G8X-xm interface modules • RFC 3587, Global Unicast Address Format • RFC 4360 BGP Extended Communities • Ping over IPv6 transport • RFC 2961 RSVP Refresh Overhead Attribute • Traceroute over IPv6 transport Reduction Extensions • RFC 4486 Subcodes for BGP Cease • RFC 5095, Internet Protocol, Version 6 • RFC 3031 Multiprotocol Label Switching Notification message (IPv6) Specification Architecture • draft-ietf-idr-restart-10.txt Graceful Restart • RFC 4861, Neighbor Discovery for IP • RFC 3032 MPLS Label Stack Encoding Mechanism for BGP Version 6, (IPv6) • RFC 3036 Label Distribution Protocol (LDP) • RFC 4760 Multiprotocol extensions for • RFC 2463, Internet Control Message • RFC 3209 RSVP-TE: Extensions to RSVP for BGP-4 Protocol (ICMPv6) for the IPv6 Specification LSP Tunnels • RFC 1657 BGP-4 MIB • RFC 2464, Transmission of IPv6 Packets over • RFC 3630 Traffic Engineering Extensions • RFC 4893 BGP Support for Four-Octet AS Ethernet Networks to OSPFv2 Number Space • RFC 2465, IPv6 MIB, General Group and • RFC 3811 Definitions of Textual Conventions • Draft-ietf-idr-bgp4-mibv2-02.txt – Enhanced Textual Conventions (TCs) for Multiprotocol Label Switching BGP-4 MIB • RFC 2466, MIB for ICMPv6 (MPLS) Management • RFC 1195 Use of OSI IS-IS for Routing in TCP/ • RFC 2462, IPv6 Stateless Address Auto • RFC 3812 Multiprotocol Label Switching IP and Dual Environments (TCP/IP transport configuration – Host Requirements (MPLS) Traffic Engineering (TE) Management only) • RFC 1981, Path MTU Discovery for IPv6, Information Base (MIB) • RFC 2763 Dynamic Hostname Exchange August 1996 – Host requirements • RFC 3813 Multiprotocol Label Switching Mechanism for IS-IS • RFC 3513, Internet Protocol Version 6 (IPv6) (MPLS) Label Switching Router (LSR) • RFC 2966 Domain-wide Prefix Distribution Addressing Architecture Management Information Base (MIB) with Two-Level IS-IS • Telnet server over IPv6 transport • RFC 3815 Definitions of Managed Objects for • RFC 2973 IS-IS Mesh Groups • SSH-2 server over IPv6 transport the Multiprotocol Label Switching (MPLS), • RFC 3373 Three-way Handshake for IS-IS Label Distribution Protocol (LDP) Point-to-Point Adjacencies IPv6 Interworking and • RFC 4090 Fast Re-route Extensions to • Draft-ietf-isis-restart-02 Restart Signaling Migration RSVP-TE for LSP (Detour Paths) for IS-IS • RFC 4379 Detecting Multi-Protocol Label • RFC 2893, Configured Tunnels • Draft-ietf-isis-ipv6-06 Routing IPv6 with Switched (MPLS) Data Plane Failures • RFC 3056, 6to4 IS-IS (LSP Ping) • Draft-ietf-isis-wg-multi-topology-11 Multi • draft-ietf-bfd-base-09.txt Bidirectional Topology (MT) Routing in IS-IS Forwarding Detection 13 Extreme Networks Data Sheet: BlackDiamond 8800 Series Technical Specifications 8900-40G6X-xm 6-port 40GBASE-X Data Center Physical Specifications QSFP+ • Direct Attach (IEEE 802 VEPA) (Supported 8900-G96T-c 96-port 10/100/1000BASE- in a feature pack) Dimensions T Gigabit Ethernet module • Priority Flow Control (IEEE 802.1Qbb) 8900-10G24X-c 24-port 10GBASE-SFP+ (Available on the BlackDiamond 8800 with BlackDiamond 8810 Chassis: 10G24X module only PN 41632B) 24.47” high x 17.51” wide x 18.23” deep BlackDiamond 8800 c-Series Modules: • XNV (ExtremeXOS Network Virtualization) (62.2 cm x 44.5 cm x 46.3 cm) G24Xc 24-port 1000BASE-X SFP G48Xc 48-port 1000BASE-X SFP BlackDiamond 8806 Chassis: G48Tc 48-port 10/100/1000BASE-T Giga- General Specifications 17.5” high x 17.51” wide x 18.23” deep bit Ethernet module, optional PoE card (44.45 cm x 44.5 cm x 46.3 cm) G48Te2 48-port 10/100/1000BASE-T Switching Capacity Power Supply: RJ-45, optional PoE card 4.75” high x 2.75” wide x 13.75” deep 10G4Xc 4-port 10GBASE-XFP BlackDiamond 8810 (12.1 cm x 6.99 cm x 34.9 cm) 10G8Xc 8-port 10GBASE-XFP • 3.8 Tbps total switching capacity MSM Module Dimensions: BlackDiamond 8500-Series Modules: • 2,840 Mpps Layer 2 HW forwarding rate 1.63” high x 15.26” wide x 15.25” deep • 2,840 Mpps Layer 3 HW forwarding rate 8500-G24X-e 24-port 1000BASE-X SFP (4.1 cm x 38.8 cm x 38.7 cm) 8500-G48T-e 48-port 10/100/1000BASE- BlackDiamond 8806 T RJ-45, optional PoE card I/O Module Dimensions: • 1,952 Gbps total switching capacity 1.63” high x 15.26” wide x 15.25” deep • 1,420 Mpps Layer 2 HW forwarding rate Pluggable Options (4.1 cm x 38.8 cm x 38.7 cm) • 1,420 Mpps Layer 3 HW forwarding rate • S-G8Xc 8-port 1G SFP card S-G8Xc, S-10G1Xc and S-10G2Xc (add-on module for MSM) Port Capacity Dimensions: • S-10G1Xc 1-port 10G XFP card (add-on module for MSM) 1.32” high x 6.94” wide x 11.19” deep BlackDiamond 8810 • S-10G2Xc 2-port 10G SFP+ card (3.35 cm x 17.63 cm x  28.42cm) • 72 ports 10GBASE-X (XENPAK) (add-on module for MSM24, MSM-48c (64 ports if 2 MSMs) S-PoE Card Dimensions: and MSM128) • 768 ports 10/100/1000BASE-T 1.25” high x 14.31” wide x 4.81” deep • S-PoE PoE card • 440 ports 1000BASE-X SFP (3.18 cm x 36.35 cm x 12.22 cm) (400 ports if 2 MSMs) IEEE 802.3 Standard • 216 ports 10GBASE-X SFP+ Weight (192 ports if 2 MSMs) G48Te2, G48Tc, and 8500-G48T-e BlackDiamond 8810 Chassis: 79 lb Gigabit Ethernet modules comply with the BlackDiamond 8806 (35.8 kg) following standards • 40 ports 10GBASE-X (XENPAK) • IEEE 802.3 10BASE-T BlackDiamond 8810 Chassis fully loaded (32 ports if 2 MSMs) • IEEE 802.3u 100BASE-T (max): 200.5 lb (90.9 kg) • 384 ports 10/100/1000BASE-T • IEEE 802.3ab 1000BASE-T • 248 ports 1000BASE-X SFP BlackDiamond 8806 Chassis: 65 lb (208 ports if 2 MSMs) G24X, G48Xa, G48Xc, and 8500-G24X-e (29.5 kg) • 120 ports 10GBASE-X SFP+ Gigabit Ethernet modules comply with the BlackDiamond 8806 Chassis fully loaded (96 ports if 2 MSMs) following standard (max): 151 lb (68.5 kg) • IEEE 802.3z 1000BASE-X Management Switch Modules Power Supply: 7 lb (3.2 kg) • The management and switching module Power Supply Options contains the control path and the switch BlackDiamond 8900-Series Modules: Both AC and DC power supplies are fabric for the BlackDiamond 8800 • 8900-MSM128 Module: 6.30 lb (2.86 kg) available • 8900-10G8X-xl Module: 7.45 lb (3.37 kg) BlackDiamond 8900-Series Modules: • AC power supplies can run from 90-264 • 8900-G48X-xl Module: 8.50 lb (3.85 kg) 8900-MSM128 BlackDiamond 8900 Man- VAC, and deliver • 8900-G48T-xl Module: 8.55 lb (3.87 kg) agement Switch Module, optional I/O port – 700W at 90V to 100V, or • 8900-40G6X-xm Module: 7.30 lb (3.31 kg) – 1200W at 200V to 220V BlackDiamond 8800 c-Series Modules: • 8900-G96T-c Module: 8.15 lb (3.7 kg) • 48V DC power supplies deliver 1200W of • 8900-10G24X-c Module: 8.35 lb (3.79 kg) 8800-MSM-48c BlackDiamond 8800 power Management Switch Module, optional I/O BlackDiamond 8800 c-Series Modules: port Power over Ethernet (PoE) • MSM-48c Module: 6.45 lb (2.93 kg) • S-G8Xc Card: 2.20 lb (1.0 kg) BlackDiamond 8500-Series Modules: 802.3af • S-10G1Xc Card: 2.10 lb (0.95 kg) 8500-MSM-24 BlackDiamond 8500 Man- • 333 ports with 802.3af class 0 devices • G48Te2 Module: 7.75 lb (3.52 kg) agement Switch Module, optional I/O port supported with 6 power supplies • S-PoE Card: 0.80 lb (0.36 kg) • 432 ports with 802.3af class 1 devices • G48Tc Module: 7.75 lb (3.52 kg) I/O Module Options supported with 6 power supplies • G24Xc Module: 6.95 lb (3.15 kg) • 432 ports with 802.3af class 2 devices BlackDiamond 8900-Series Modules: • G48Xc Module: 7.55 lb (3.42 kg) supported with 6 power supplies 8900-10G8X-xl 8-port 10GBASE-X XFP • 10G4Xc Module: 6.50 lb (2.95 kg) • 333 ports with 802.3af class 3 devices 8900-G48T-xl 48- port • 10G8Xc Module: 6.91 lb (3.13 kg) supported with 6 power supplies 10/100/1000BASE-T, RJ45, optional PoE BlackDiamond 8500-Series Modules: 8900-G48X-xl 48-port 10GBASE-X SFP • 8500-MSM24 Module: 6.45 lb (2.93 kg) • 8500-G48T-e Module: 7.75 lb (3.52 kg) • 8500-G24X-e Module: 6.95 lb (3.15 kg) 14 Extreme Networks Data Sheet: BlackDiamond 8800 Series Technical Specifications G48Te 48-port 10/100/1000BASE-T Giga- 10GX4 and 10G4Xa 10 Gigabit Ethernet Power bit Ethernet module 2:1 oversubscription modules comply with the following stan- BlackDiamond 8810 Chassis with Fan G24X 24-port 1000BASE-X Gigabit dard: IEEE 802.3ae 10GBASE-X Trays: 55W (Heat Dissipation: 188 BTU) Ethernet module, SFP modules required 10G4Ca complies with the following stan- G48Xa 48-port 10/100/1000BASE-T dard: IEEE 802.3ak 10GBASE-CX4 BlackDiamond 8806 Chassis with Fan Gigabit Ethernet module, SFP modules Trays: 45W (Heat Dissipation: 154 BTU) required BlackDiamond 8900-Series Modules: Operating 10G4X 4-port 10GBASE-X 10 Gigabit Eth- 8900-MSM128 Module: 150W ernet module, XENPAK modules required Specifications (Heat Dissipation: 512 BTU) 10G4Xa 4-port 10GBASE-X Gigabit 10G8X-xl Module: 250W Ethernet module, XFP modules required (Heat Dissipation 853 BTU) Operating Conditions 10G4Ca 4-port 10GBASE-CX4 10 Gigabit G48T-xl Module: 150W Operating Temperature Range: Ethernet module (Heat Dissipation 512 BTU) 0° C to 40° C (32° F to 104° F) G48X-xl Module: 175W Physical Specifications Operating Humidity: 10% to 93% relative (Heat Dissipation 598 BTU) humidity, non-condensing Weight 40G6X-xm Module: 140W Operational Shock: 30 m/s2 (3g), 11ms, MSM-G8X Module: 7.5 lb (3.1 kg) (Heat Dissipation 478 BTU) 60 Shocks MSM-48 Module: 7.5 lb (3.1 kg) 8900-10G24X-c Module: 250W Operational Sine Vibration: G48Pe Module: 6.75 lb (3.06 kg) (Heat Dissipation: 853 BTU) 5-100-5 HZ @ 0.2G, 0-Peak, 01 Oct./min. G48T Module: 7.75 lb (3.5 kg) 8900-G96T-c Module: 250W Operational Random Vibration: G48P Module: 8 lb (3.6 kg) (Heat Dissipation: 699 BTU) 3-500MHz @ 1.5g rms G48Ta Module: 6.75 lb (3.1 kg) BlackDiamond 8800 c-Series Modules: G48Te Module: 6.75 lb (3.06 kg) MSM-48 Module: 150W G48Xa Module: 8 lb (3.6 kg) Regulatory/Safety (Heat Dissipation: 512 BTU) G24X Module: 7.75 lb (3.5 kg) G48Te2 Module: 110W Standards 10G4X Module: 7.75 lb (3.5 kg) (Heat Dissipation: 376 BTU) 10G4Xa Module: 6.5 lb (2.9 kg) G48Tc Module: 110W 10G4Ca Module: 6.5 lb (2.9 kg) North American Safety of ITE (Heat Dissipation: 376 BTU) • UL 60950-1:2003 1st Ed., Listed Device (U.S.) Power G48Tc Module with S-PoE card: 110W • CSA 22.2#60950-1-03 1st Ed.(Canada) MSM-G8X Module: 150W (Heat Dissipation: 376 BTU) • Complies with FCC 21CFR Chapter1, (Heat Dissipation: 512 BTU) G24Xc Module: 100W Subchapter J (U.S. Laser Safety) MSM-48 Module: 150W (Heat Dissipation: 341 BTU) • CDRH Letter of Approval (U.S. FDA Approval) (Heat Dissipation: 512 BTU) G48Xc Module: 125W • IEEE 802.3af 6-2003 Environment A for G48Pe Module: 120W (Heat Dissipation: 427 BTU) PoE Applications (Heat Dissipation: 409 BTU) 10G4Xc Module: 100W G48T Module: 105W (Heat Dissipation: 341 BTU) European Safety of ITE (Heat Dissipation: 358 BTU) 10G8Xc Module: 135W • EN60950-1:2001+A11 G48P Module: 110W (Heat Dissipation: 461 BTU) • EN 60825-1+A2:2001 (Lasers Safety) (Heat Dissipation: 375 BTU) • TUV-R GS Mark by German Notified Body BlackDiamond 8500-Series Modules: G48Ta Module: 120W • 73/23/EEC Low Voltage Directive 8500-MSM24 Module: 150W (Heat Dissipation: 409 BTU) (Heat Dissipation: 512 BTU) G48Te Module: 120W International Safety of ITE 8500-G48T-e Module: 110W (Heat Dissipation: 409 BTU) • CB Report & Certificate per IEC (Heat Dissipation: 376 BTU) G24X Module: 105W 60950-1:2001+All Country Deviations 8500-G24X-e Module: 100W (Heat Dissipation: 358 BTU) • AS/NZX 60950-1 (Australia/New Zealand) (Heat Dissipation: 341 BTU) G48Xa Module: 105W (Heat Dissipation: 358 BTU) Legacy Products 10G4X Module: 105W EMI/EMC Standards (Heat Dissipation: 358 BTU) Management Switch Modules: 10G4Xa Module: 120W MSM-G8X Module: BlackDiamond 8800 North America EMC for ITE (Heat Dissipation: 409 BTU) Management Switch Module, with 8 • FCC CFR 47 part 15 Class A (U.S.) 10G4Ca Module: 105W 1000BASE-X SFP ports • ICES-003 Class A (Canada) (Heat Dissipation: 358 BTU) MSM-48 Module: BlackDiamond 8800 Management Switch Module, no I/O port IEEE 802.3 Standard European EMC Standards G48Pe, G48T, G48P, G48Te and G48Ta I/O Module Options: • EN 55022:1998 Class A Gigabit Ethernet modules comply with the G48Pe 48-port 10/100/1000BASE-T • EN 55024:1998 Class A following standards – Includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11 Gigabit Ethernet module with PoE 2:1 • IEEE 802.3 10BASE-T • EN 61000-3-2,3 (Harmonics & Flicker) oversubscription • IEEE 802.3u 100BASE-T • ETSI EN 300 386:2001 G48T 48-port 10/100/1000BASE-T • IEEE 802.3ab 1000BASE-T (EMC Telecommunications) Gigabit Ethernet module • 89/336/EEC EMC Directive MSM-G8X Gigabit Ethernet module G48P 48-port 10/100/1000BASE-T complies with the following standard: IEEE Gigabit Ethernet module with PoE 802.3z 1000BASE-X G48Ta 48-port 10/100/1000BASE-T Gigabit Ethernet module 15 Extreme Networks Data Sheet: BlackDiamond 8800 Series Technical Specifications International EMC IEEE 802.3 Media Warranty Certifications Access Standards • Ltd. 1-year on Hardware • CISPR 22:1997 Class A • 90-days on Software (International Emissions) • IEEE 802.3z 1000BASE-X • BlackDiamond 8500-Series Modules Feature • IEEE 802.3ab 1000BASE-T • CISPR 24:1997 Class A a Limited Lifetime Warranty with Express (International Immunity) • IEEE 802.3ae 10GBASE-X Advanced Hardware Replacement. Modules • IEEE 802.3ak 10GBASE-CX4 • IEC/EN 61000-4-2 Electrostatic Discharge, include: 8kV Contact, 15kV Air, Criteria A • IEEE 802.3af Power over Ethernet – 8500-MSM24 • IEC/EN 61000-4-3 Radiated Immunity – 8500-G24X-e 10V/m, Criteria A – 8500-G48T-e Environmental • IEC/EN 61000-4-4 Transient Burst, 1kV, For warranty details, visit Criteria A • EN/ETSI 300 019-2-1 v2.1.2 – www.extremenetworks.com/go/warranty • IEC/EN 61000-4-5 Surge, 2kV, 4kV, Class 1.2 Storage Criteria A • EN/ETSI 300 019-2-2 v2.1.2 – • IEC/EN 61000-4-6 Conducted Immunity, Class 2.3 Transportation 0.15-80MHz, 10V/m unmod. RMS, Criteria A • EN/ETSI 300 019-2-3 v2.1.2 – • IEC/EN 61000-4-11 Power Dips & Class 3.1e Operational Interruptions, >30%, 25 periods, Criteria C • EN/ETSI 300 753 (1997-10) – Acoustic Noise • NEBS GR-63 Issue 2 – Sound Pressure Country Specific • ASTM D3580 Random Vibration • VCCI Class A (Japan Emissions) Unpackaged 1.5G • AS/NZS 3548 ACA (Australia Emissions) • CNS 13438:1997 Class A (BSMI-Taiwan) • NOM/NYCE (Mexico) • MIC Mark, EMC Approval (Korea) Telecom Standards • ETSI EN 300 386:2001 (EMC Telecommunications) • ETSI EN 300 019 (Environmental for Telecommunications) 16 Extreme Networks Data Sheet: BlackDiamond 8800 Series Ordering Information Part Number Description Information 41011 10-Slot Chassis BlackDiamond 8810 10-Slot Chassis including Fan Tray 41012 6-Slot Chassis BlackDiamond 8806 6-Slot Chassis including Fan Tray 700W/1200W 100-240V 60020 BlackDiamond 10808/BlackDiamond 8800 700W/1200W 100-240V PSU PSU 41050 600W/900W PSU BlackDiamond 8806 600W/900W 100-240V PSU 60021 1200W -48V DC PSU BlackDiamond 10808/BlackDiamond 8800 1200W -48V DC PSU Management Module Options BlackDiamond 8900-Series Modules 41231 8900-MSM128 BlackDiamond 8900 Management Switch Module, optional I/O port BlackDiamond 8800 c-Series Modules 41213 MSM-48c BlackDiamond 8800 Management Switch Module, optional I/O port BlackDiamond 8500-Series Modules 41251 8500-MSM24 BlackDiamond 8500 Management Switch Module, optional I/O Port I/O Module Options BlackDiamond 8900-xl/xm Series Modules 41711 8900-40G8X-xm BlackDiamond 8900-xm 6-port 40GBASE-X, QSFP+ 41631 8900-10G8X-xl BlackDiamond 8900 8-port 10GBASE-X, XFP 41531 8900-G48T-xl BlackDiamond 8900 48-port 10/100/1000BASE-T RJ-45, optional PoE card 41521 8900-G48X-xl BlackDiamond 8900 48-port 1000BASE-X, SFP BlackDiamond 8900-Series Modules 41632B 8900-10G24X-c BlackDiamond 8900 24-port 10GBASE-X SFP+ 41532 8900-G96T-c BlackDiamond 8900 96-port 10/100/1000BASE-T MRJ-21 BlackDiamond 8800 c-Series Modules 41516 G48Te2 BlackDiamond 8800 48-port 10/100/1000BASE-T RJ-45, optional PoE card 41517 G48Tc BlackDiamond 8800 48-port 10/100/1000BASE-T RJ-45, optional PoE card 41543 G24Xc BlackDiamond 8800 24-port 1000BASE-X SFP 41544 G48Xc BlackDiamond 8800 48-port 1000BASE-X SFP 41614 10G4Xc BlackDiamond 8800 4-port 10GBASE-XFP 41615 10G8Xc BlackDiamond 8800 8-port 10GBASE-XFP BlackDiamond 8500-Series Modules 41551 8500-G48T-e BlackDiamond 8500 48-port 10/100/1000BASE-T RJ-45, optional PoE card 41561 8500-G24X-e BlackDiamond 8500 24-port 1000BASE-X SFP Pluggable Options 41821 S-G8Xc BlackDiamond 8800 8-port 1G SFP card (add-on module for MSM) 41822 S-10G1Xc BlackDiamond 8800 1-port 10G XFP card (add-on module for MSM) 41823 S-10G2Xc BlackDiamond 8800 2-port 10GBASE-X SFP+ card (add-on module for MSM-24, MSM-48c and MSM128) 41811 S-PoE BlackDiamond 8800 PoE card Accessories 41311 Core License BlackDiamond 8800 ExtremeXOS Core Software Upgrade 41312 BD8800 MPLS ExtremeXOS MPLS Feature Pack for BlackDiamond 8800 series switches, requires MSM128 Feature Pack and 8900-XL interface modules 41311 Core License BlackDiamond 8800 ExtremeXOS Core Software Upgrade 17 Extreme Networks Data Sheet: BlackDiamond 8800 Series Ordering Information Part Number Description Information Accessories 41312 BD8800 MPLS ExtremeXOS MPLS Feature Pack for BlackDiamond 8800 series switches, requires MSM128 Feature Pack and 8900-XL interface modules 11011 Direct Attach Direct Attach Feature Pack for Summit X450a/X460/X480, Summit X650 and Feature Pack BlackDiamond 8800 Series with ExtremeXOS 12.5.1 or Greater 41111 Spare Fan Tray BlackDiamond 8810 Spare Fan Tray 65043 Spare Fan Tray BlackDiamond 8806 Spare Fan Tray 41112 Spare PSU/Fan Controller BlackDiamond 8800 Spare PSU/Fan Controller Board 41121 Spare Blank Panel BlackDiamond 8800 Spare Blank Panel 41141 Mid Mount Kit BlackDiamond 8810 Mid Mount Kit 41151 Cable Management Clip Kit BlackDiamond 8800 Cable Management Kit 10312 QSFP+ passive copper QSFP+ passive copper cable, 1.0M cable, 1.0M 10315 QSFP+ active fiber cable, QSFP+ active fiber cable, 10M 10M 10318 QSFP+ active fiber cable, QSFP+ active fiber cable, 100M 100M 10301 10GBASE-SR SFP+ 10GBASE-SR SFP+, 850nm, LC Connector, transmission length of up to 300m on MMF 10302 10GBASE-LR SFP+ 10GBASE-LR SFP+, 1310nm, LC Connector, transmission length of up to 10km on SMF 10309 10GBASE-ER SFP+ 10GBASE-ER SFP+, 1550nm, LC connector, transmission length of up to 40km on SMF 10303 SFP+ LRM Module 10 Gigabit Ethernet SFP+ module, 1310nm, legacy MMF 220m link, LC connector 10304 10GBASE-CR SFP+ 1m 10GBASE-CR SFP+ pre-terminated twin-ax copper cable with link lengths of 1m 10305 10GBASE-CR SFP+ 3m 10GBASE-CR SFP+ pre-terminated twin-ax copper cable with link lengths of 3m 10306 10GBASE-CR SFP+ 5m 10GBASE-CR SFP+ pre-terminated twin-ax copper cable with link lengths of 5m 10307 10GBASE-CR SFP+ 10m 10GBASE-CR SFP+ pre-terminated twin-ax copper cable with link lengths of 10m 10051 1000BASE-SX SFP 1000BASE-SX SFP, LC Connector 10052 1000BASE-LX SFP 1000BASE-LX SFP, LC Connector 10053 1000BASE-ZX SFP 1000BASE-ZX SFP, Extra Long Distance SMF 70 km/21 dB Budget, LC Connector 10056 1000BASE-BX-D SFP 1000BASE-BX-D SFP, SMF (1490nm TX/1310nm RX Wavelength) 10057 1000BASE-BX-U SFP 1000BASE-BX-U SFP, SMF (1310nm TX/1490nm RX Wavelength) 10060 100FX/1000LX SFP SFP, Dual-speed 100 FX/1000LX, LC Connector 10063 100FX SFP Module SFP, 100BASE-FX MMF, LC Connector 10064 1000BASE-LX100 SFP 1000BASE-LX100 SFP, Extra Long Distance SMF 100 km/30dB Budget, LC Connector 10065 10/100/1000BASE-T SFP 10/100/1000BASE-T, SFP, CAT 5 cable 100m, RJ-45 Connector 10121 SR XFP Module 10GBASE-SR XFP Transceiver, 850nm up to 300m on Multimode Fiber, LC Connector 10122 LR XFP Module 10GBASE-LR XFP Transceiver, 1310nm, up to 10km on Single-mode Fiber, LC Connector 10124 ER XFP Module 10GBASE-ER XFP Transceiver, 1550nm up to 40km on Single-mode Fiber, LC Connector 10200 Tunable DWDM XFP 10 Gigabit Ethernet XFP Tunable DWDM module, C-band, SMF 80 km, LC Connector Corporate Europe, Middle East, Africa Asia Pacific Japan and North America and South America Phone +65 6836 5437 Phone +81 3 5842 4011 Extreme Networks, Inc. Phone +31 30 800 5100 3585 Monroe Street Make Your Network Mobile Santa Clara, CA 95051 USA Phone +1 408 579 2800 extremenetworks.com © 2011 Extreme Networks, Inc. All rights reserved. Extreme Networks, the Extreme Networks logo, BlackDiamond, Extreme Standby Routing Protocol, ExtremeXOS, ExtremeXOS Screenplay, Ridgeline and Summit are either registered trademarks or trademarks of Extreme Networks, Inc. in the United States and/or other countries. sFlow is the property of InMon Corporation. Specifications and product availability are subject to change without notice. 1023_26 08/11

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 10G4Xc have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Extreme Networks 10301 SFP+ Module - 10GBASE-SR SFP+, 850nm, LC Connector, transmission length of up...

product

Extreme Networks 10302 SFP Module - 10GBASE-LR SFP+, 1310nm, LC Connector, transmission length of up...

product

Extreme Networks 10303 SFP Module - 10 Gigabit Ethernet SFP+ module, 1310nm, legacy MMF 220m link, L...

product

Extreme Networks 10304 Copper Cable - 10GBASE-CR SFP+ pre-terminated twin-ax copper cable with link ...

product

Extreme Networks 10305 Copper Cable - 10GBASE-CR SFP+ pre-terminated twin-ax copper cable with link ...

product

Extreme Networks 10306 Copper Cable - 10GBASE-CR SFP+ pre-terminated twin-ax copper cable with link ...