EMERSON 00375-0002-0044

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number 00375-0002-0044
Manufacturer EMERSON
Category PRODUCTS - 0
Price Request Quote
Lead Time Request Quote

Description

Emerson 00375-0002-0044 Battery Pack for 375 Hart Field Communicator & Charger

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Elite.Parts is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 00375-0002-0044? We can help you find it at a competitive price!

Datasheet

Download "Emerson-375 Series-datasheet1-2017884837.pdf" (799 KiB)

Extracted Text

Product Data Sheet February 2009 375 Field Communicator 375 Field Communicator ®  Universal–HART and TM FOUNDATION fieldbus  User upgradeable  Intrinsically safe  Rugged and reliable ®  Interfaces with AMS Suite: Intelligent Device Manager  Graphical interface The 375 Field Communicator is designed to support all HART and FOUNDATION fieldbus devices from all vendors. The result is the universal, Introduction user upgradeable, intrinsically The 375 Field Communicator has safe, rugged and reliable established itself as the standard 375 Field Communicator. in handheld communicators. HART users worldwide told us how to make a better communicator. Fieldbus users said they wanted a portable, intrinsically safe communicator that supported all their fieldbus devices. www.fieldcommunicator.com Product Data Sheet February 2009 and product images are just a few of the ways that important device data can be displayed using the Graphics Option. The weight of the 375 Field Communicator is evenly distributed for comfortable one-handed operation. It Is Loaded! The 375 Field Communicator has plenty of memory to allow for future expansion. It has 32 MB of application memory, and 1 GB of memory on its System Card. The Configuration Expansion Module holds hundreds of device configurations, and it is externally accessible. The battery pack allows a full recharge in 2 hours. Easy Upgrade Keeps Your Communicator Current The 375 Field Communicator is also Designed not only for use on the bench, the 375 Field Communicator also user upgradeable via the Internet. enables you to do those tasks that just have to be done in the field. It is no longer necessary to send away to have new device drivers, The touch-screen display uses Product Description functionality, or licenses added to transflective technology, making it your 375 Field Communicator. The 375 Field Communicator easy to read in both bright sunlight includes features designed to New HART and FOUNDATION fieldbus and in normal lighting. To make sure simplify your work in the field. devices, as well as functional all conditions are covered, a multi- Use a single intuitive user interface updates to existing devices, are level backlight is included, allowing for both HART and FOUNDATION introduced continually by device the display to be viewed even in fieldbus devices. The 375 Field vendors. Keeping up-to-date with areas of your plant with dim light. Communicator includes a larger the required Device Descriptions The touch-screen display and touch screen than PDAs or (DDs) for all the devices in your large physical navigation buttons Pocket PCs, HART Revision 6 plant can be a real challenge. ™ allow efficient use both on the and 7 (including WirelessHART ) As new HART and FOUNDATION bench and in the field. support, and the ability to upgrade fieldbus DDs become available, onsite using the Internet. The Graphics Option for the simply download them from the 375 Field Communicator uses See the Difference Internet and upgrade your powerful EDDL technology that The 375 Field Communicator 375 Field Communicator. allows you to read data from runs on Windows CE, a robust, field devices in a graphical real-time operating system. manner. Charts, graphs, gauges, Page 2 375 Field Communicator The 375 Field Communicator, with its handy carrying case, provides a single tool for configuring and diagnosing HART and FOUNDATION fieldbus devices. Universal – HART and Diagnose Network Problems Detect power supply problems FOUNDATION fieldbus The 375 Field Communicator by monitoring low frequency noise The 375 Field Communicator can be used to configure all the on a segment. Locate incorrect is designed to support all FOUNDATION fieldbus devices terminations and faulty devices by HART and FOUNDATION fieldbus in your plant. Use it to perform diagnosing the communications devices. With access to new diagnostics for effective start-up signal level. device drivers over the Internet, and troubleshooting of For HART loops, the you are guaranteed universal FOUNDATION fieldbus segments. 375 Field Communicator allows HART and FOUNDATION fieldbus Create a quality segment by you to verify whether the DC support in a single, intrinsically diagnosing the network DC voltage in the loop is correct. safe handheld communicator. voltage and average noise. With over 1,200 different HART and FOUNDATION fieldbus devices from more than 100 different vendors, the 375 Field Communicator is a single communicator that works with all your devices to positively impact your bottom line. Page 3 Product Data Sheet February 2009 Easy Upgrade allows you to transfer system software and DDs between the 375 Field Communicator and a PC using either IrDA or an SD Card Reader. Transfer configuration data between the 375 and AMS Device Manager or update Device Descriptions and functionality. User Upgradeable communicator to a service center Online Licensing As functional enhancements to to have new DDs or software The Online Licensing capability HART and FOUNDATION fieldbus updates added. Easy Upgrade provided with Easy Upgrade applications become available, lets you update your own 375 allows you to enable new options download the updates from the Field Communicator and avoid for your 375 Field Communicator Internet and upgrade your waiting for your upgrades. Update over the Internet. By using this 375 Field Communicator. It is no at your site, within your control, feature, you can add powerful longer necessary to send your when it’s convenient for you. new options such as FOUNDATION fieldbus and Graphics by merely purchasing and downloading them to your 375 Field Communicator. Page 4 (()) ( ) ((())) 375 Field Communicator Intrinsically Safe Even the battery is approved for Its large keys and physical The 375 Field Communicator meets installation in hazardous areas. navigation buttons allow for one- the Intrinsic Safety requirements The 375 Field Communicator is handed operation, even with your of the listed regulatory agencies designed for use in areas where work gloves on. The rugged display and standards. All of the available laptops cannot go. is designed to take the knocks and Hazardous Locations approvals shocks from normal use in the plant. Rugged and Reliable are provided in a single model It’s called “Field Communicator” for The 375 Field Communicator option (see Ordering Information). a reason. Some tasks just have to is designed, manufactured, and – CENELEC/ATEX be performed at the device. The tested to very demanding – Factory Mutual (FM) 375 Field Communicator is designed specifications. The 375 Field – Canadian Standards for tough use in your plant or mill. Communicator goes wherever you Association (CSA) have to go to get the job done. – FISCO – IECEX ATEX Specifications POWER SUPPLY Specifications ENVIRONMENTAL Specifications PROCESSOR AND MEMORY Specifications Battery Pack (NiMH) Usage  Microprocessor Rechargeable NiMH cells  -10° C (14° F ) to +50° C (122° F ) ®   80 MHz Hitachi SH3 Up to 10 hours operating time  0% to 95% RH (non-condensing) (depending on usage) for 0° C (32°F ) to +50° C (122° F ) Memory Internal Flash  Up to 40 hours standby time  32 MB Charge  Power Module (Lithium-Ion) optional 10° C (50° F ) to +40° C (104° F) System Card  Rechargeable Li-Ion cells  1 GB secure digital card Storage With Batteries  Up to 20 hours operating time  -20° C (-4° F ) to +55° C (131° F ) RAM (depending on usage)  32 MB  Storage Without Batteries Up to 80 hours standby time  -20° C (-4° F ) to +60° C (140° F) Expansion Module Power Supply/Charger Options  32 MB or higher secure digital card  Enclosure Rating Input voltage 100-240 VAC, 50/60 Hz   IP51 (from front) Cables included with U.S., European, PHYSICAL Specifications U.K., and Australia plugs Shock Weight  Tested to survive a 1-meter CONNECTION Specifications  Approximately 2 lb. (0.9kg) with battery drop test onto concrete Battery Charger Display EASY UPGRADE REQUIREMENTS  1/4 VGA (240 by 320 pixels)  Mini DIN 6-pin jack for Li-Ion Power monochrome 3.8” (9.6 cm) transflective Usage Module  display with touch screen  PC with Internet access Mini DIN 6-pin to 4-pin adapter cable   Anti-glare coated CD Rom drive for NiMH Battery Pack  IrDA port (or adapter) Keypad HART and Fieldbus  Windows XP, SP 2  25 keys including 4 action keys,  Three 4mm banana plugs (one common 12 alphanumeric keys, 4 programmable to HART and FOUNDATION fieldbus) function keys, on/off/standby, and IrDA Port 4 cursor-control (arrow) keys;  IrDA (Infrared Data Access) port membrane design with tactile feedback supporting up to 115 Kbps  ±15 degrees recommended maximum angle from center line  Approximately 12” (30 cm) recommended maximum distance Page 5 Product Data Sheet February 2009 Interfaces with Together, the 375 Field AMS Device Manager Communicator and AMS Device Manager enable you to The 375 Field Communicator is efficiently manage all of your fully compatible with AMS Device devices, the assets that are the Manager, the industry standard Transfer device configuration foundation of your process. for asset management software. data to AMS Device Manager In fact, Control Magazine readers via the IrDA port on the 375 Field have selected AMS Device Manager Communicator and your PC. Carry as the #1 Calibration Software your 375 Field Communicator out package for over 10 years in a row. to the field to configure or update AMS Device Manager uses the one or many devices. Save device intelligence from field devices to configurations in your 375 Field create a predictive maintenance Communicator or transfer them environment. AMS Device Manager to AMS Device Manager. The allows you to configure, calibrate, optional Configuration Expansion The Configuration Expansion document, and troubleshoot Module easily stores 500 or more Module safely stores hundreds of device configurations. HART, FOUNDATION fieldbus, device configurations safely in and WirelessHART devices. your 375 Field Communicator. Page 6 375 Field Communicator 375 Field Communicator Spare Parts List Description Part Number Ruggedized 250 Ohm Load Resistor 00275-0096-0001 Rechargeable NiMH Battery Pack with Accessory Case 00375-0002-0011 Rechargeable Li-Ion Power Module with Accessory Case (7) 00375-0002-0022 Rechargeable Li-Ion Power Module with Power Supply/Charger 00375-0002-0044 Power Supply/Charger for NiMH/Li-Ion (100-240 VAC, 50/60Hz,US/UK/EU connection types included) 00375-0003-0022 NiMH Battery Pack Adapter Cable (8) 00375-0003-0008 Leadset with connectors 00375-0004-0001 Mounting Straps 00375-0005-0002 Carrying Case (with straps) 00375-0005-0003 Accessory Case (clips to Carrying Case) 00375-0005-0004 Stylus (pack of 5) 00375-0006-0001 IrDA to USB Adapter (1) 00375-0015-0002 System Card (SD) Reader (with USB Interface) (2) 00375-0018-0022 Expansion Port Plug 00375-0035-0001 System Card - HART with Easy Upgrade (3 years) (3) 00375-0042-0003 System Card - HART and FOUNDATION fieldbus with Easy Upgrade (3 years) (3) 00375-0042-0004 System Card - HART with Easy Upgrade (3 years) and Graphics (3) 00375-0042-0013 System Card - HART and FOUNDATION fieldbus with Easy Upgrade (3 years) and Graphics (3) 00375-0042-0014 Configuration Expansion Module 00375-0043-0001 Stand and Utility Plate 00375-0044-0001 Getting Started Guide 00375-0045-0001 User’s Manual 00375-0047-0001 Resource CD (4) 00375-0049-0001 375 Online Licensing FOUNDATION fieldbus License Via Web (4) 00375-0142-0002 Easy Upgrade (New) License Via Web (4) 00375-0142-0003 Easy Upgrade (Renew) License Via Web (4) (5) 00375-0142-2003 Graphics License Via Web (4) 00375-0142-0010 AMS Device Manager Handheld Interface Kit AMS Device Manager Handheld Communicator Interface Kit (25 tags) (6) AW7005HC00025 AMS Device Manager Handheld Communicator Interface Kit (100 tags and above) (6) AW7005HC20000 (1) Can be used to support communication between the 375 Field Communicator and the Easy Upgrade Programming Utility or AMS Suite: Intelligent Device Manager (with Handheld Communicator Interface Kit). IrDA is required to register the 375 or use the Online Licensing system. (2) Compared to using IrDA, the System Card (SD) Reader provides a much faster alternative to upgrading a System Card. The ability to use a card reader exists with Easy Upgrade Programming Utility 1.6.0 (or higher). Due to file size constraints, some upgrades require the use of a card reader. (3) These system cards should only be used on communicators with serial numbers greater than 24.000. Using these cards in older units will cause unpredictable behavior. (4) This part is for a field upgrade of System Cards via the Online Lincensing system by the end user. An agent may also perform this on the user’s behalf. It is at the agent’s discretion if an additional fee should apply. Any order must be accompanied by the System Card Serial Number which can be obtained by interfacing the 375 Field Communicator with v 1.6.0 (or higher) of the Easy Upgrade Programming Utility. Notification that the licenses are available for download can be sent to an email address provided at time of order. (5) The Renew option is available for System Cards where the Easy Upgrade license has not been expired for more than 90 days. Date of expiration can be obtained by interfacing the 375 Field Communicator with v 1.6.0 (or higher) of the Easy Upgrade Programming Utility. (6) Requires AMS Device Manager (V 6.2 or higher). Both AMS Device Manager and the Handheld Communicator Interface Kit are available for sale through select channels only. See www.ams.assetweb.com for further details. (7) Requires Power Supply/Charger 00375-0003-0022. Will not work with older charger 00375-0003-0011. (8) Required to use Power Supply/Charger with NiMH Battery Pack. Included with 00375-0003-0022 Power Supply/Charger. Page 7 Product Data Sheet February 2009 375 Field Communicator 375 Field Communicator Ordering Information Model Product Description 375 Field Communicator (1) Code Communication Protocol H HART F HART and FOUNDATION fieldbus (2) Code Battery Type R Rechargeable NiMH Battery Pack P Rechargeable Lithium-Ion Power Module Code Power Supply/Charger 1 Power Supply/Recharger NiMH/Li-Ion (100/240 VAC, 50/60Hz, US/UK/EU connection types included) (3) 9 Not included (4) Code Language E English Code Product Certifications KL CENELEC/ATEX, FM, CSA, and IECEx Intrinsically Safe (includes FISCO as applicable) NA No Approval Code Easy Upgrade U Easy Upgrade (3 year) Option (5) 9 Not Included Code Options A Power Module (6) (10) B Spare Rechargeable NiMH Battery Pack (6) (9) C Configuration Expansion Module (7) G Graphics Option (2) (8) Typical HART Model Number: 375 H P 1 E KL U Typical HART/Fieldbus Model Number: 375 F P 1 E KL U (1) Base Model 375 includes Field Communicator Unit, System Card, Leadset with Connectors, Carrying Case, Getting Started Guide, User’s Manual, 375 Resource CD, Stylus and Straps. (2) Must specify Easy Upgrade Option (Code U) when ordering this model option. (3) To obtain Australian Power cord, order part numbers 00375-0003-0003. (4) This option should be considered only if the user already has a 375 Power Supply/Charger that supports the battery type they are ordering. (5) The Easy Upgrade capability allows the user to add new System Application software and Device Descriptions (DDs) to the 375 for a period of 3 years. To upgrade without this feature, the System Card would have to be sent to a Service Center. (6) A fully charged NiMH battery pack is capable of delivering power for 8 hours of typical field use, whereas a Li-Ion Power Module is capable of delivering 20 hours. If requirements exceed this specification, a second battery pack is (Code B or A) recommended. (7) The 375 is capable of storing a total of 25 configurations. For increased storage capacity, use the Configuration Expansion Module which is capable of storing in excess of 500 configurations. (8) The Graphics Option enables a user to access Enhanced Graphical features when using the HART or FOUNDATION fieldbus applications (as applicable). (9) Available with NiMH Battery Type R only. (10) Available with Li-Ion Battery Type P only. ©2009, Emerson Process Management. Emerson Process Management The contents of this publication are presented for informational purposes only, and while every effort has Asset Optimization Division been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express 12001 Technology Drive or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the Eden Prairie, MN 55344 USA right to modify or improve the designs or specifications of our products at any time without notice. T 1(952) 828-3206 All rights reserved. AMS is a mark of one of the Emerson Process Management group of companies. The Emerson logo is a trademark and service mark of Emerson Electric Co. F 1(952) 828-3006 All other marks are the property of their respective owners. www.fieldcommunicator.com

Related Products

EMERSON
Emerson 002153911000020M Full Height Baying Kit 46U
EMERSON
Emerson 00375-0003-0002 Power Supply/Charger Standard Cord Set (US/UK/EU co...
EMERSON
Emerson 00375-0003-0011 375 Field Communicator Spare Power Supply/Charger (...
EMERSON
Emerson 00375-0003-0022 Power Supply/Charger for Lithium Battery Pack Batte...
EMERSON
Emerson 00375-0005-0003 375 Field Communicator Spare Carrying Case (with st...
EMERSON
Emerson 00375-0018-0022 System Card (SD) Reader (with USB Interface) | for...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Elite.Parts are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Elite.Parts is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.124 seconds.