TELEMECANIQUE TSXTLYEX

Description
Telemecanique TSXTLYEX Line Terminator - Line terminators are made up of a 9-pin SUB D connector and a cover containing the adaptation components. They are mounted on the 9-pin SUB D connector on the extension module at each end of the line.
Part Number
TSXTLYEX
Price
Request Quote
Manufacturer
TELEMECANIQUE
Lead Time
Request Quote
Category
COMPONENTS
Datasheet
Extracted Text
BMX XBE 1000 rack extender module 17 At a Glance Goal of this The goal of this Chapter is to introduce the rack extender module and its installation. Chapter What's in this This chapter contains the following topics: Chapter? Topic Page Rack Extender Module Introduction 192 Rack Extender Module Physical Description 195 Rack Extender Module Installation 197 Rack extender Module Configuration 202 Rack Extender Module Diagnostics 205 Rack Extender Module Accessories 207 35012676.02 07/2008 191 BMX XBE 1000 rack extender module Rack Extender Module Introduction General The Modicon PLC rack extender module makes it possible to connect a maximum of 4 racks, depending on the CPU, distributed along a maximum length of 30 meters. The racks are daisy chained together via the extension modules. 192 35012676.02 07/2008 BMX XBE 1000 rack extender module Example of A typical system consists of: topology z A rack extender module (BMX XBE 1000) in each rack, z A power supply module in each rack, z One CPU for the complete system, z 2 line terminators, TSX on the first rack and TLY on the last. 35012676.02 07/2008 193 BMX XBE 1000 rack extender module Module Consumption on 3.3 VDC power supply: 22 mA. consumption Dissipated power on the 3.3 VDC rack power supply : 73 mW. Consumption on 24 VDC rack power supply : 160 mA Dissipated power on the 24 VDC rack power supply : 3.84 W 194 35012676.02 07/2008 BMX XBE 1000 rack extender module Rack Extender Module Physical Description Illustration 1 3 2 35012676.02 07/2008 195 BMX XBE 1000 rack extender module Table of labels The BMX XBE 1000 module is composed of the following elements: Label Description 1 Module status LEDs on the front: z RUN LED: indicates the operating status of the module, z COL LED: indicates a collision error of the module, z 0 to 3 LEDs: indicates the rack address of the module. 2 Two female SUB.D 9 pin connectors for bus cables or terminators. 3 Coding switches. 196 35012676.02 07/2008 BMX XBE 1000 rack extender module Rack Extender Module Installation Installation The following modules must be placed in these slots: z The BMX XBE 1000 module is installed on each BMX XBP rack in the slot marked XBE. z Each rack must include a power supply module, in position CPS. z The processor must be installed in the main rack (rack 0) in position 00. The following illustration shows the installed the BMX XBE 1000 extender module with power supply, processor and two I/O modules in the main rack (rack 0): DANGER HAZARD OF ELECTRIC SHOCK Disconnect all power sources before installing the module. Failure to follow these instructions will result in death or serious injury. 35012676.02 07/2008 197 P 3 4 2 0 3 0 6 0 5 D D M1 6 0 2 5 P 3 4 2 0 3 0 D D M 1 2 .R UN . ERR .I/O . .C AN RUN .CAN ERR . .CARD ERR .ET H ACT .. ETH ST 0S 0 . ETH 1 E h A C A d res s: t M 00-80 -F4-02 -E 4-D B BMX XBE 1000 rack extender module Assembly The assembly of the BMX XBE 1000 module is similar to the assembly of the BMX P34 processors (see Fitting of Processors, p. 78), and generally speaking, similar to the assembly of the other modules. Leave 12 mm of free space on the right side of the rack to insure a free flow of air for cooling. Leave 35 mm in front of the module for the local bus connector and terminator. Grounding of the The BMX XBE 1000 module is equipped with ground connection contacts (see Rack Extender Grounding of Installed Modules, p. 29). Module Building a The BMX XBP racks can be used to build a PLC station that contains a Modicon M340 maximum of: Station Using Station Maximum number of BMX XBP racks Processor OS Version Racks For a BMX P34 1000/2010/2020/2030 station 01.00 1 BMX XBP racks For a BMX P34 1000 station >= 02.00 2 BMX XBP racks For a BMX P34 2000/2010/2020/2030 station >= 02.00 4 BMX XBP racks 198 35012676.02 07/2008 BMX XBE 1000 rack extender module Diagram: 2 1 2 35012676.02 07/2008 199 P342030 P342030 O ..R U. N R R . E. C I/A.N ERR . CAN RU .C NAR RD R E .ETH AC. T ETH STS . .ET1 H 0 0 Eh t MAA Cd r ess: 00-80 -F 4-0 2E - 4 -D B P342030 P342030 P342030 BMX XBE 1000 rack extender module z (1) The same station can contain 4, 6, 8 and 12 position racks that are intercon- nected by Extension cables (see Rack Extender Module Accessories, p. 207). z (2) The local bus must have a Line terminator (see Rack Extender Module Accessories, p. 207) fitted at each end. Note: The cumulative length of all the BMX XBC •••K or TSX CBY •••K cables used in a PLC station must not exceed 30 meters. Extension Cable Racks are connected by means of BMX XBC K or TSX CBY K extension cables which are connected to the 9-pin SUB-D connectors situated on the BMX XBE 1000 module of each main and extension rack. Line Terminators The BMX XBE 1000 modules of the two racks situated at the start and at the end of the chain must always be fitted with TSX TLY EX line terminators on the unused 9- pin SUB-D connectors. Line terminators are labeled A/ or /B. A PLC station that uses extension modules must use one line terminator labeled A/ and one labeled /B. For example, if the extension module in the first rack of the chain contains a terminator labeled A/, then the extension module in the last rack must contain a terminator labeled /B 200 35012676.02 07/2008 BMX XBE 1000 rack extender module Positioning of Positioning on a PLC station containing several BMX XBP extension racks: Line Terminators BMX XBE 1000 on a TSX TLYEX Modicon M340 Station BMX XBP xxxx TSXTLYEX TSXTLYEX TSXTLYEX TSXTLYEX A A B B BMX XBP xxxx BMX XBC xxxK / TSX CBY xxxK TSXTLYEX TSXTLYEX TSXTLYEX TSXTLYEX A A B B BMX XBP xxxx TSX TLYEX Positioning on a PLC station containing a single BMX XBE 1000 extension module: TSXTLYEX TSXTLYEX TSXTLYEX TSXTLYEX BMX XBE 1000 A A B B TSX TLYEX BMX XBP xxxx TSX TLYEX TSXTLYEX TSXTLYEX TSXTLYEX TSXTLYEX A A B B 35012676.02 07/2008 201 BMX XBE 1000 rack extender module Rack extender Module Configuration At a Glance The rack extender modules are configured using microswitches on the side of the modules. The configuration of the module must be done before mounting the module on the rack. PLC station rack addressing depends on the number of racks used: z PLC station built with a single rack, z PLC station built with extension racks. Station built with If the PLC station is built with a single rack, the rack address is implicit and has a a single rack value of 0. If a rack extender module is installed in this rack, line terminators must be connected to the local bus connectors, and the microswitches on the side of the module must be configured for rack 0 (refer to the table of rack addresses in the next paragraph). 202 35012676.02 07/2008 BMX XBE 1000 rack extender module Station built with For a PLC station built with extension racks, an address must be assigned for each extension racks station rack. This address is coded using 3 microswitches on the side of the module. Microswitches 1 to 3 are used to code the rack address on the local bus (address 0 to 3). Diagram showing the microswitches: Table of rack addresses: Switch Rack Address 012 3 1 OFF OFF OFF OFF 2OFF OFF ON ON 3OFF ON OFF ON 4 Not applicable Note: On delivery, all the microswitches are delivered in the OFF position (address 0). 35012676.02 07/2008 203 BMX XBE 1000 rack extender module Assigning Address 0: this address is always assigned to the rack which supports the addresses to BMX P34 1000/2000/2010/2020/2030 processor. different racks This rack can be located in any position in the chain. If two or more racks are configured with address 0, only the rack supporting the processor will function correctly. Addresses 1 to 3: can be assigned in any order to all the other extension racks in the station. If two or more racks are configured with the same rack address (other than 0), the behavior depends on the position of the modules in those racks: z If each module position is only used once, the modules will function correctly. z If modules are mounted in the same position on two or more racks, those racks will not function, the access to them will be blocked. 204 35012676.02 07/2008 BMX XBE 1000 rack extender module Rack Extender Module Diagnostics BMX XBE 1000 The BMX XBE 1000 module display panel, located on the front of the module, is Module LEDs used for diagnostics. Illustration:display panel (see Rack Extender Module Physical Description, p. 195) 35012676.02 07/2008 205 BMX XBE 1000 rack extender module Description The following table describes the different LEDs and their meanings: LED Pattern Indication RUN (green): on Module functioning normally operational state off z The power supply is no longer present, or z Internal module detected error COL (red): collision on Two or more racks are coded with the same rack address, error detected and either: z Rack address is 0: this rack does not contain the processor; modules are mounted in the same rack position on each rack. There will be no communication on the local bus for this rack or z Rack address is not 0: modules are mounted in the same rack position on each rack. There will be no communication on the local bus for this rack. off The rack addresses are correct. 0 to 3 (green): on Rack address To resolve a collision error detected, carry out the following actions: Step Action 1 Power off the principal supply of the racks in collision. 2 Correct the rack address. 3 Power on the principal supply. 206 35012676.02 07/2008 BMX XBE 1000 rack extender module Rack Extender Module Accessories Extension Cable These cables of predetermined length are used to chain BMX XBP racks and to BMX XBC K transport the different local bus signals. and They are equipped at each end with a male 9-pin SUB D connector, which connect TSX CBY K to the female 9-pin SUB D connector on the rack extender modules. The BMX XBC K cables use connectors angled at 45°. BMX XBC K TSX CBY K Note: The cumulative length of all the cables used in a PLC station is limited to 30 meters. CAUTION INRUSH CURRENT Insertion and extraction of a BMX XBC •••K or a TSX CBY •••K cable must only be done with all the station’s elements switched off (racks, PC, etc.) Failure to follow these instructions can result in injury or equipment damage. 35012676.02 07/2008 207 BMX XBE 1000 rack extender module Summary table of different cable types available: Reference Length Modicon M340 cable BMX XBC 008K 0.8 m BMX XBC 015K 1.5 m BMX XBC 030K 3 m BMX XBC 050K 5 m BMX XBC 120K 12 m Premium cable TSX CBY 010K 1 m TSX CBY 030K 3 m TSX CBY 050K 5 m TSX CBY 120K 12 m TSX CBY 180K 18 m 208 35012676.02 07/2008 BMX XBE 1000 rack extender module Line Terminators The local bus must be fitted with a line terminator at each end. TSX TLY EX Line terminators are made up of a 9-pin SUB D connector and a cover containing the adaptation components. They are mounted on the 9-pin SUB D connector on the extension module at each end of the line. Illustration TSX TLY EX line terminators are provided in pairs marked A/ and /B. The must be fitted with a terminator A/ at one end and a terminator /B at the other end. CAUTION INRUSH CURRENT Insertion or extraction of a line terminator must only be done with all the station’s racks switched off. Failure to follow these instructions can result in injury or equipment damage. 35012676.02 07/2008 209 BMX XBE 1000 rack extender module 210 35012676.02 07/2008 BMX XBP xxxx Rack Functions 18 At a Glance Subject of this This section describes the different functions of the BMX XBP racks. Section What's in this This chapter contains the following topics: Chapter? Topic Page Module Addressing 212 Installing the Power Supply Modules, Processors and Other Modules 213 35012676.02 07/2008 211 BMX XBP •••• Rack Functions Module Addressing Introduction For all racks, the module address is geographic. It is based on its position on the rack. Module The following table shows the module addresses depending on the rack used. Addressing Rack reference Number of slots available for Module address the modules BMX XBP 0400 4 00 - 03 BMX XBP 0600 6 00 - 05 BMX XBP 0800 8 00 - 07 BMX XBP 1200 12 00 - 11 212 35012676.02 07/2008 BMX XBP •••• Rack Functions Installing the Power Supply Modules, Processors and Other Modules General A rack must house one power supply module and one processor. Module The rules for installing modules on a rack are as follows: Installation z The power supply module must always be installed in the slot marked CPS. Rules z The processor must be installed in the slot marked 00. z The I/O and application-specific modules are installed in slots marked 01 to n (n varies according to the rack, see below table). z The extension module is always installed in the slot marked XBE. WARNING UNEXPECTED EQUIPMENT OPERATION Check that the processor module is installed in slot 00 before powering up the system. Otherwise unexpected equipment operation can result. Failure to follow these instructions can result in death, serious injury, or equipment damage. The following illustration shows the BMX XBP 0400 rack with the module slot numbers: XBE CPS 01 02 00 03 It is possible to connect three I/O and application-specific modules to this rack using the connectors marked 01 to 03. 35012676.02 07/2008 213 BMX XBP •••• Rack Functions The following table describes the slot numbers to which the I/O and application- specific modules may be connected on BMX XBP racks. Rack Module slot number (n) BMX XBP 0400 01 - 03 BMX XBP 0600 01 - 05 BMX XBP 0800 01 - 07 BMX XBP 1200 01 - 11 214 35012676.02 07/2008
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the TSXTLYEX have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods