SL POWER / CONDOR POWER GPM55-5
Features
- Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3
- Complies with EN61000-3-2 Class A
- Conducted EMI complies with FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models)
- Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601
- RoHS Compliant Model Available (G suffix)
- Single and multiple outputs
- Wide-range ac input 85-264 Vac
Datasheet
GPM55-5.pdf
215 KiB
Extracted Text
GPC55 Commercial/GPM55 Medical 55 Watt Global Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 Complies with EN61000-3-2 Class A Single and multiple outputs marked to LVD SPECIFICATIONS: Ac Input Output Noise 85-264 Vac, 47-63 Hz single phase. 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output Input Current terminals of the power supply. Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.7 A Transient Response Main output—500 µs typical response time for return to Hold-Up Time within 0.5% of final value for a 50% load step change. Δi/ 20 ms minimum from loss of ac input at full load, nominal Δt<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/ line (115 Vac). shutdown overshoot less than 3%. Output Power Voltage Adjustment 55 W continuous, 70 W peak. Peak ratings are for 60 s Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2. maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation EMI/EMC Compliance limits. All models include built-in EMI filtering to meet the following emissions requirements: Overload Protection EMI SPECIFICATIONS COMPLIANCE LEVEL Fully protected against short circuit and output overload. Conducted Emissions GPC55 EN55022 Class B; FCC Class B Short circuit protection is cycling type power limit on Conducted Emissions GPM55 EN55011 Class B; FCC Class B outputs 1 & 2; foldback type on outputs 3 & 4. Recovery Static Discharge EN61000-4-2, 6 kV contact, 8 kV air after fault is automatic. See output ratings chart for RF Field Susceptibility EN61000-4-3, 3 V/meter additional notes or conditions. Factory set to begin power Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz limiting at approximately 75 W. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Line Frequency Harmonics EN61000-3-2 Class A Overvoltage Protection Main outputs: 124% + 12% Commercial Leakage Current 0.7 mA 254 Vac @ 60 Hz input. Efficiency 70% at full rated load, nominal input voltage, depending Commercial Safety on model and load distribution. Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file #E135803 commercial; CSA Input Protection #LR46516 all models. The output(s) are intended for Internal ac fuse provided. Designed to blow only if a safety earthed Signal Output and Intermediate Circuits catastrophic failure occurs in the unit. only. All dc outputs are SELV under normal and single fault conditions. Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac Medical Leakage Current under cold start conditions will not exceed 34 A. 35 µA 254 Vac @ 60 Hz input. Temperature Coefficient Medical Safety 0.03%/°C typical on all outputs. Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL file E116994; CSA #LR46516. The output(s) Environmental are intended for safety earthed Signal Output and Designed for 0 to 50°C operation at full rated output Intermediate Circuits only. The output(s) are not power; derate output current and total output power by acceptable for patient connection without additional 2.5% per °C above 50°C. See Environmental and isolation. All dc outputs are SELV under normal and Packaging Specifications on next page. single fault conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 FAX 805-487-8911 www.condorpower.com 34 GPC55 Commercial/GPM55 Medical 55 Watt Multiple Output Commercial Medical Output Output Model Model Output No. Output Minimum Maximum Output Peak Noise P-P Total Regulation (A) GPC55A GPM55A 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +12 V 0 A 3 A 5 A 120 mV 2% 3 +12 V 0 A 1 A 1.2 A 120 mV 3% 4 -12 V 0 A 1 A 1.2 A 120 mV 3% GPC55B GPM55B 1 + 5 V 0.7 A 6 A 8 A 50 mV 2% 2 +12 V 0 A 3 A 5 A 120 mV 2% 3 -5 V 0 A 1 A 1.2 A 50 mV 3% 4 -12 V 0 A 1 A 1.2 A 120 mV 3% GPC55C GPM55C 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +15 V 0A 3 A 5 A 150 mV 2% 3 -5 V 0A 1 A 1.2 A 50 mV 3% 4 -15 V 0A 1 A 1.2 A 150 mV 3% GPC55D GPM55D 1 +5 V 0.7A 6 A 8 A 50 mV 2% 2 +24 V 0 A 1.5 A 2 A 240 mV 2% 3 +12 V 0 A 1 A 1.2 A 120 mV 3% 4 -12 V 0 A 1 A 1.2 A 120 mV 3% GPC55E GPM55E 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +24 V 0 A 1.5 A 2 A 120 mV 2% 3 +15 V 0 A 1 A 1.2 A 150 mV 3% 4 -15 V 0 A 1 A 1.2 A 150 mV 3% GPC55F GPM55F 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +12 V 0 A 3 A 5 A 120 mV 2% 3 +15 V 0 A 1 A 1.2 A 150 mV 3% 4 -15 V 0 A 1 A 1.2 A 150 mV 3% GPC55-5 GPM55-5 1V5A0A1A 1 1V 4 5% 0 m 2 GPC55-l2 GPM55-12 1V1A 2 0A4A .7 5V .8 1% 20 m 2 GPC55-15 GPM55-15 1V1A 5 0A3A .7 4V .7 1% 50 m 2 GPC55-24 GPM55-24 1V2A 4 0A2A .3 2V .9 2% 40 m 2 GPC55-28 GPM55-28 1V2A 8 0A2A .0 2V .4 2% 80 m 2 GPC55-48 1V4A 8 0A1A .5 1V .5 4% 80 m 2 A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. GPC55/GPM55 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Ts emperature (A)S5 ee individual spec -40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions HH umidity (A)0H to 95% R 0 to 95% R before application of power. Sg hock (B) 20 40 g B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 pk pk orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. At ltitude-t 500 to 10,000 f -500 to 40,000 f C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz total 6 shocks. rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 35
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the GPM55-5 have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods