SL POWER / CONDOR POWER GLC75C
Specifications
Altitude
500 to 10,000 ft -500 to 40,000 ft
Humidity(A)
0 to 95% RH 0 to 95% RH
Noise P-P
50 mV 120 mV150 mV 150 mV
Output
+5.1 V +12 V -15 V +15 V
Output Maximum (A)
10 A 3 A 1 A3 A
Output Minimum
1 A 0.5 A 0 A 0 A
Output No.
4
Output Peak
12 A 4A 1.2 A 4 A
REGULATION
2% +10% -5% (D) 3% 2%
RoHS Suffix
G
Shock (B)
20g pk 40g pk
Temperature(A)
0 to 50° -40 to +85°C
V1 OVP Set
6.2 ± 0.6 V
Vibration
(C) 1.5 g rms’0.003 g2/Hz 5 g rms’ 0.026 g2/Hz
Features
- 7.00”x 4.25”x 1.30” (Meets 1U height)
- Also available in single output versions
- Class B (Commercial models) and CISPR 11 Class B
- Commercial UL1950 3rd Edition, CSA22.2 No. 950 and
- Complies with EN61000-3-2 Class A
- Conducted EMI exceeds FCC Class B and CISPR 22
- Cost-effective multiple output power source
- CSA22.2 No. 601.1-M90, and IEC/EN60601-1
- EN60950-1 approvals
- Medical Approved to UL2601-1,
- RoHS Compliant Model Available (G suffix)
- Universal input 90-264 Vac
Datasheet
Extracted Text
GLOBAL PERFORMANCE SWITCHERS GLC75 Commercial/GLM75 Medical 75 Watt Multiple Output Global Performance Switchers FEATURES: • Cost-effective multiple output power source • Universal input 90-264 Vac • 7.00”x 4.25”x 1.30” (Meets 1U height) • 2-year warranty • Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) • Complies with EN61000-3-2 Class A • Also available in single output versions • Commercial UL1950 3rd Edition, CSA22.2 No. 950 and EN60950-1 approvals • Medical Approved to UL2601-1, CSA22.2 No. 601.1-M90, and IEC/EN60601-1 • RoHS Compliant Model Available (G suffix) SPECIFICATIONS Efficiency Ac Input 68% -78% depending on model and load distribution. 90-264 Vac, 47-63 Hz single phase. Input Protection Input Current Internal ac fuse provided on all units. Designed to blow only if a catastrophic Maximum input current at 120 Vac, 60 Hz with full rated output load not to failure occurs in the unit. exceed 2.3 A. Inrush Current Output Power Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac Normal continuous output power is 75 W for unrestricted natural convection half-cycle under cold start conditions will not exceed 37 A. cooling or 110 W with 26 cfm airflow. During peak load conditions output regulation may exceed total regulation and noise limits. Hold Up Time 20 ms minimum from loss of ac input power at full load, nominal line (120 Vac). Output Regulation Measured by ±40% load change from 60% rated load with all other outputs Temperature Coefficient at 60% rated load and input voltage change from minimum to maximum rat- 0.03%/°C typical on all outputs. ings. Output #1 requires 1A minimum load for proper regulation of other Power Fail outputs. Initial set tolerance is measured with all outputs at 60% of full rated A standard TTL or CMOS compatible output goes low (< 0.5 V) 5ms before output load. Output #2 requires 0.5A minimum load for proper regulation. voltage drops more than 4% below nominal voltage upon loss of ac power. Signal Overload Protection is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line Factory set to begin power limiting at approximately 120 W. Fully protected impedance and distortion. Other settings are available through adjustment of against short circuit and output overload. Short circuit protection is cycling built-in potentiometer (consult factory for assistance). Output will stay low for 20 type power limit. ms minimum. Output Noise EMI/EMC Compliance 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with All models include built-in EMI filtering to meet the following emissions requirements: noise probe directly across output terminals of the power supply. EMI SPECIFICATIONS COMPLIANCE LEVEL Transient Response Main Output: 500μSec typical response time for return to within 0.5% of final Conducted Emissions GLC75 EN55022 Class B; FCC Class B value for a 50% load step change, ∆i/∆t<0.2A/μSec. Maximum voltage devia- Conducted Emissions GLM75 EN55011 Class B: FCC Class B tion is 3.5%. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Overvoltage Protection Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Built in on V1 with firing point set per table. OVP firing reduces output #1 and Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. #2 to less than 50% of nominal voltage in 50 ms. Line Frequency Harmonics EN61000-3-2 Class A Voltage Adjust Commercial Safety Factory set on standard unit; however, optional potentiometer (“-V” suffix) All GLC models are approved to UL1950 3rd Edition, CSA22.2 No. 950, and adjusts voltage from 4.7 V to OVP point (6.2 V nominal) on the +5 V output. EN60950-1. Note: Output #1 must not be more than 1% below nominal to achieve full output voltage range on Output #2. Output regulation limits in some models Medical Leakage Current may be exceeded when the main output is adjusted beyond +1% of nominal 70 μA 264 V @ 50 Hz (normal conditions). voltage. High voltage settings may degrade the reliability of the unit due to Medical Safety excessive power dissipation in some outputs. GLM models are approved to UL2601-1, CSA22.2 No. 601.1M90, IEC/EN60601-1. CB Report available. O All specifications are typical at nominal input, full load at 25 C unless otherwise stated Commercial Medical RoHS Output Output Output Output Output Model Model Suffix* No. Output Minimum Maximum (A) Maximum (B) Peak V1 OVP Set Noise P-P Regulation GLC75A GLM75A G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 ± 0.6 V 50 mV 2% 2 +12 V 0.5 A 2.5 A 3 A 4 A 120 mV +10%,-5% (D) 3 -12 V 0 A 1 A 1 A 1.2 A 120 mV 3% 4 +12 V 0 A 2.5 A 3 A 4 A 120 mV 2% GLC75B GLM75B G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 ± 0.6 V 50 mV 2% 2 +12 V 0.5 A 2.5 A 3 A 4 A 120 mV +10%,-5% (D) 3 -5 V 0 A 1 A 1 A 1.2 A 50 mV 3% 4 +12 V 0 A 2.5 A 3 A 4 A 120 mV 2% GLC75C GLM75C G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 ± 0.6 V 50 mV 2% 2 +12 V 0.5 A 2.5 A 3 A 4 A 120 mV +10%,-5% (D) 3 -15 V 0 A 1 A 1 A 1.2 A 150 mV 3% 4 +15 V 0 A 2.5 A 3 A 4 A 150 mV 2% GLC75D GLM75D G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 ± 0.6 V 50 mV 2% 2 +24 V 0.5 A 2.5 A 2.5 A 3.5 A 240 mv +10%,-5% (D) 3 -12 V 0 A 1 A 1 A 1.2 A 120 mV 3% 4 +12 V 0 A 2.5 A 3 A 4 A 120 mV 2% GLC75E GLM75E G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 ± 0.6 V 50 mV 2% 2 +24 V 0.5 A 2.5 A 2.5 A 3.5 A 240 mV +10%,-5% (D) 3 -15 V 0 A 1 A 1 A 1.2 A 150 mV 3% 4 +15 V 0 A 2.5 A 3 A 4 A 150 mV 2% GLC75F GLM75F G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 ± 0.6 V 50 mV 2% 2 +15 V 0.5 A 2.5 A 3 A 4 A 150 mV +10%,-5% (D) 3 -5 V 0 1 A 1 A 1.2 A 50 mV 3% 4 -15 V 0 2.5 A 3 A 4 A 150 mV 2% GLC75H GLM75H G 1 +5.1 V 1A 8 A 10 A 12 A 6.2 ± 0.6 V 50 mV 2% 2 +15 V 0.5 A 2.5 A 3 A 4 A 150 mV +10%,-5% (D) 3 -15 V 0 1 A 1 A 1.2 A 150 mV 3% 4 +15 V 0 2.5 A 3 A 4 A 150 mV 2% GLC75J GLM75J G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 ± 0.6 V 50 mV 2% 2 +12 V 0.5 A 2.5 A 3 A 4 A 120 mV +10%,-5% (D) 3 -12 V 0 1 A 1 A 1.2 A 120 mV 3% 4(C) 5 V 0 2.0 A 3 A 4 A 50 mV 2% GLC75P GLM75P G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 ± 0.6 V 50 mV 2% 2 +24 V 0.5 A 4 A 4 A 4.5 A 240 mv +10%,-5% (D) 3 -12 V 0 A 1 A 1 A 1.2 A 120 mV 3% 4 +12 V 0 A 2.5 A 3 A 4 A 120 mV 2% * Add “G” suffix to part number for RoHS compliant model. Contact factory for availability. A. Rating with unrestricted convection cooling. Total power not to exceed 75 W. B. Rating with 26 cfm forced-air cooling. Total power not to exceed 110 W. C. Floating fourth output can be referenced as either positive or negative. Connect pin 12 to Return to provide a positive voltage at Pin 13. Connect pin 13 to Return to provide a negative voltage at Pin 12. D. To maintain these regulations conditions, the +5V current must be at least 1/5 of V2 and not greater than 5 times the V2 current. Requires +5V to be adjusted to within 1% with at least a 1 A load to maintain regulation on this output. GLC75/GLM75 - MULTIPLE OUTPUT - MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output current and total Temperature (A) 0 to 50° -40 to +85°C output power by 2.5% per °C above 50°C. Humidity (A) 0 to 95% RH 0 to 95% RH B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 Shock (B) 20 g 40 g orthogonal axes, total 6 shocks. pk pk Altitude -500 to 10,000 ft -500 to 40,000 ft C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms’ rms’ hr./axis non-operating. SL Power Electronics, Inc., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 9-23-10. Data Sheet © 2010 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the GLC75C have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
Related Products

SL Power / Condor Power GLC75J Power Supply. Open Frame | Commercial | 75 W | 5.1V, +-12V, 5V DC Qua...

SL Power / Condor Power GLD140F Power Supply. Open Frame | Medical | 140 W | 5V, 15V, +-12V DC Quad ...

SL Power / Condor Power GLD140G Power Supply. Open Frame | Medical | 140 W | 5V, 3.3V, +-12V Quad Ou...

SL Power / Condor Power GLM110-12 Power Supply. Open Frame | Medical | 110 W | 12 VDC @ 6.3A Single ...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods