Elite.Parts chervon right Manufacturers chervon right S chervon right SL POWER / CONDOR POWER chervon right GPM225-28
About product Datasheet FAQ

SL POWER / CONDOR POWER GPM225-28

Image of SL POWER / CONDOR POWER GPM225-28

Description

POWER SUP SWITCHER 225W 28V MED

Part Number

GPM225-28

Price

Request Quote

Manufacturer

SL POWER / CONDOR POWER

Lead Time

Request Quote

Category

POWER

Datasheet

pdf file

GPC225-15.pdf

174 KiB

Extracted Text

GPC225 Commercial/GPM225 Medical 225 Watt Global Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 marked to LVD SPECIFICATIONS: Ac Input 85-264 Vac, 47-63 Hz single phase. line impedance and distortion. Other settings are avail- able to the user through adjustment of built-in potentiometer. Input Current Maximum input current at 120 Vac, 60 Hz with full rated Output Noise output load: 5.5 A 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output Hold-Up Time terminals of the power supply. 20 ms minimum from loss of ac input at full load, nominal line (115 Vac). Transient Response 500 µs typical response time for return to within 0.5% of Output Power final value for a 50% load step change. Δi/Δt<0.2 A/µs. 175 W convection; 225 W with 26 cfm air; 250 W peak. Peak Maximum voltage deviation is 3.5%. Startup/shutdown ratings are for 60 s maximum duration, 10% duty cycle. overshoot less than 3%. Overload Protection Remote Sense Fully protected against short circuit and output overload. Provided as a standard feature. Short circuit protection is cycling type power limit. Recovery after fault is automatic. Factory set to begin Voltage Adjustment power limiting at approximately 250 W. Built-in potentiometer adjusts voltage ±5%. Overvoltage Protection EMI/EMC Compliance 124% ± 12% typical. All models include built-in EMI filtering to meet the following emissions requirements: Efficiency EMI SPECIFICATIONS COMPLIANCE LEVEL 70% at full rated load, nominal input voltage, depending Conducted Emissions GPC225 EN55022 Class B; FCC Class B on model and load distribution. Conducted Emissions GPM225 EN55011 Class B; FCC Class B Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Input Protection RF Field Susceptibility EN61000-4-3, 3 V/meter Internal ac fuse provided. Designed to blow only if a Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz catastrophic failure occurs in the unit. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Inrush Current Commercial Leakage Current Inrush is limited by internal thermistors. Inrush at 240 Vac 0.95 mA 254 Vac @ 60 Hz input (with no deviations). under cold start conditions will not exceed 60 A. Commercial Safety Temperature Coefficient Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950, 0.03%/°C typical on all outputs. EN60950 and CISPR22. UL file #E135803 commercial; CSA #LR46516. The output(s) are intended for safety Thermal Shutdown earthed Signal Output and Intermediate Circuits only. All Provided as a standard feature. Designed to protect unit dc outputs are SELV under normal and single fault from prolonged over temperature. conditions. Environmental Medical Leakage Current Designed for 0 to 50°C operation at full rated output 60 µA. 254 Vac @ 60Hz input. power; derate output current and total output power by 2.5% per °C above 50°C. See Environmental and Medical Safety Packaging Specifications on next page. Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL file E116994; CSA #LR46516. The output(s) Power Fail are intended for safety earthed Signal Output and TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms Intermediate Circuits only. The output(s) are not accept- before output voltage drops more than 4% below nominal able for patient connection without additional isolation. All voltage upon loss of ac power. The signal is factory set to dc outputs are SELV under normal and single fault trip on 84 to 94 Vac brown-out depending upon incoming conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565  FAX 805-487-8911  www.condorpower.com 66 GPC225 Commercial/GPM225 Medical 225 Watt Multiple Output Commercial Medical Output Output Output Model Model Output Minimum Maximum (B) Maximum (C) Peak Noise P-P Total Regulation (A) GPC225-5 GPM225-5 5A V 0A3A 4 4A 0 4V 5 5% 0 m 2 GPC225-12 GPM225-121A 2 V 0A1A 5.8 1A 9 2V 0 1% 20 m 2 GPC225-15 GPM225-151A 5 V 0A1A 2.7 1A 5 1V 6 1% 50 m 2 GPC225-24 GPM225-242A 4 V 0A8A .3 9A .4 1V 0 2% 40 m 2 GPC225-28 GPM225-282A 8 V 0A7A .1 8A8V .5 2% 80 m 2 A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Unrestricted natural convection cooling. C. Requires 26cfm moving air. GPC225/GPM225 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Ts emperature (A)S5 ee individual spec -40 to +8 C HH umidity (A)0H to 95% R 0 to 95% R A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Sg hock (B) 20 40 g pk pk B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 At ltitude-t 500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz total 6 shocks. rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929  805-486-4565  FAX 805-487-8911  www.condorpower.com 67

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the GPM225-28 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

SL Power / Condor Power GLC75C Power Supply. Open Frame | Commercial | 5.1V, 12V, +-15V DC Quad Outp...

product

SL Power/Condor Power GLC75D Switch - 75 Watt Single Output Global Performance Switchers

product

SL Power / Condor Power GLC75J Power Supply. Open Frame | Commercial | 75 W | 5.1V, +-12V, 5V DC Qua...

product

SL Power / Condor Power GLD140F Power Supply. Open Frame | Medical | 140 W | 5V, 15V, +-12V DC Quad ...

product

SL Power / Condor Power GLD140G Power Supply. Open Frame | Medical | 140 W | 5V, 3.3V, +-12V Quad Ou...

product

SL Power / Condor Power GLM110-12 Power Supply. Open Frame | Medical | 110 W | 12 VDC @ 6.3A Single ...