SL POWER / CONDOR POWER GPM130E
Specifications
Ac Input
85-264 Vac, 47-63 Hz single phase.
Efficiency
70% at full rated load, nominal input voltage, depending on model and load distribution.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions requirements:Conducted Emissions GPC130:EN55022 Class B; FCC Class B; Conducted Emissions GPM130:EN55022 Class B; FCC Class B; Static Discharge:EN61000-4-2, 6 kV contact, 8 kV air; RF Field Susceptibility:EN61000-4-3, 3 V/meter; Fast Transients/Bursts:EN61000-4-4, 2 kV, 5 kHz; Surge Susceptibility:EN61000-4-5, 1 kV diff., 2 kV com.
Environmental
Designed for 0 to 50°C operation at full rated output power;
Hold-Up Time
20 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load: 3.5 A
Input Protection
Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 34 A.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.
Output Power
100 W continuous, 165 W peak; 130 W with 26 cfm air flow. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits.
Overload Protection
Factory set to begin power limiting at approximately 170 W.
Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on outputs 1 & 2; foldback type on outputs 3 & 4. Recovery after fault is automatic.
Overvoltage Protection
Main outputs: 124% ± 12% typical.
Power Fail
TTL- or CMOS-compatible output goes low (
Remote Sense
Provided as a standard feature on output 1.
Temperature Coefficient
0.03%/°C typical on all outputs.
Thermal Shutdown
Provided as a standard feature. Designed to protect unit from prolonged overtemperature.
Transient Response
Main output—500µSec typical response time for return to within 0.5% of final value for a 50% load step change. ?i/?t
Turn-on Time
Less than 1 second at 120 Vac, 25°C (inversely proportional to input voltage and thermistor temperature).
Voltage Adjustment
Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.
Datasheet
Condor Engineering-GPC130A-1.pdf
275 KiB
Extracted Text
GPC130 Commercial/GPM130 Medical 130 Watt Global Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Commercial Approved to UL1950, IEC950, EN60950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) marked to LVD Power Fail SPECIFICATIONS: TTL- or CMOS-compatible output goes low (< 0.5V) 5 ms Ac Input before output voltage drops more than 4% below nominal 85-264 Vac, 47-63 Hz single phase. voltage upon loss of ac power. The signal is factory set to trip on 84 to 94Vac brown-out depending upon incoming line Input Current impedance and distortion. Other settings are available to the Maximum input current at 120 Vac, 60 Hz with full rated output user through adjustment of built-in potentiometer. load: 3.5 A Output Noise Hold-Up Time 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. 20 ms minimum from loss of ac input at full load, nominal line Measured with noise probe directly across output terminals of (115 Vac). the power supply. Output Power Transient Response 100 W continuous, 165 W peak; 130 W with 26 cfm air flow. Peak Main output—500µSec typical response time for return to within ratings are for 60 s maximum duration, 10% duty cycle. During 0.5% of final value for a 50% load step change. Δi/Δt<0.2 A/µs. peak load condition, output regulation may exceed total Maximum voltage deviation is 3.5%. Startup/shutdown overshoot regulation limits. less than 3%. Overload Protection Remote Sense Fully protected against short circuit and output overload. Short Provided as a standard feature on output 1. circuit protection is cycling type power limit on outputs 1 & 2; foldback type on outputs 3 & 4. Recovery after fault is automatic. Voltage Adjustment See output ratings chart for additional notes or conditions. Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2. Overvoltage Protection Overload Protection Main outputs: 124% ± 12% typical. Factory set to begin power limiting at approximately 170 W. Efficiency EMI/EMC Compliance 70% at full rated load, nominal input voltage, depending on model All models include built-in EMI filtering to meet the following and load distribution. emissions requirements: EMI SPECIFICATIONS COMPLIANCE LEVEL Turn-on Time Conducted Emissions GPC130 EN55022 Class B; FCC Class B Less than 1 second at 120 Vac, 25°C (inversely proportional to Conducted Emissions GPM130 EN55022 Class B; FCC Class B input voltage and thermistor temperature). Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Input Protection Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Internal ac fuse provided. Designed to blow only if a catastrophic Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. failure occurs in the unit. Commercial Leakage Current Inrush Current 0.7 mA 254 Vac @ 60 Hz input. Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 34 A. Commercial Safety Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and Temperature Coefficient EN60950. UL file #E135803 commercial; CSA #LR46516 all models. The output(s) are intended for safety earthed Signal 0.03%/°C typical on all outputs. Output and Intermediate Circuits only. All dc outputs are SELV under normal and single fault conditions. Thermal Shutdown Provided as a standard feature. Designed to protect unit from Medical Leakage Current prolonged overtemperature. 35 µA 254 Vac @ 60 Hz input. Environmental Medical Safety Designed for 0 to 50°C operation at full rated output power; Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL derate output current and total output power by 2.5% per °C file E116994; CSA #LR46516. The output(s) are intended for above 50°C. See Environmental and Packaging Specifications safety earthed Signal Output and Intermediate Circuits only. The on next page. output(s) are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 FAX 805-487-8911 www.condorpower.com 54 GPC130 Commercial/GPM130 Medical 130 Watt Multiple Output Commercial Medical Output Output Output Total Model Model Output No. Output Minimum Maximum (B) Maximum (C) Output Peak Noise P-P Regulation (A) GPC130A GPM130A 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +12 V 0 A 5 A 5 A 8 A 120 mV 2% 3 -12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% 4 +12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% GPC130B GPM130B 1 + 5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +12 V 0 A 5 A 5 A 8 A 120 mV 2% 3 -5 V 0 A 1.2 A 1.2 A 1.5 A 50 mV 3% 4 -12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% GPC130C GPM130C 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +12 V 0 A 5 A 5 A 8 A 120 mV 2% 3 -15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3% 4 +15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3% GPC130D GPM130D 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +24 V 0 A 3.5 A 3.5 A 5 A 240 mV 2% 3 -12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% 4 +12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3% GPC130E GPM130E 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2% 2 +24 V 0 A 3.5 A 3.5 A 5 A 240 mV 2% 3 -15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3% 4 +15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3% A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Unrestricted natural convection cooling. C. Requires 26 cfm moving air. GPC130/GPM130 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Ts emperature (A)S5 ee individual spec -40 to +8 C HH umidity (A)0H to 95% R 0 to 95% R A. Units should be allowed to warm up/operate under non-condensing conditions Sg hock (B) 20 40 g pk pk before application of power. B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 At ltitude-t 500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz rms rms total 6 shocks. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 55
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the GPM130E have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
SL Power / Condor Power GLC75C Power Supply. Open Frame | Commercial | 5.1V, 12V, +-15V DC Quad Outp...
SL Power / Condor Power GLC75J Power Supply. Open Frame | Commercial | 75 W | 5.1V, +-12V, 5V DC Qua...
SL Power / Condor Power GLD140F Power Supply. Open Frame | Medical | 140 W | 5V, 15V, +-12V DC Quad ...
SL Power / Condor Power GLD140G Power Supply. Open Frame | Medical | 140 W | 5V, 3.3V, +-12V Quad Ou...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods