SL POWER / CONDOR POWER GPFM125B
Features
- Commercial approved to UL1950, IEC950, CSA22.2 No. 950 and EN60950.
- Compact 125 watt multiple output
- Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models)
- Medical approved to UL2601-1, IEC601-1, CSA22.2 No. 601.1, EN60601-1
- Power density of 4 watts per cubic inch
- Power Factor Correction to meet EN61000-3-2
- Small package 6.00 x 3.5 x 1.5 inches
Datasheet
Extracted Text
GPFC125 Commercial/GPFM125 Medical 125 Watt Global Performance Switchers FEATURES: Compact 125 watt multiple output Power density of 4 watts per cubic inch Power Factor Correction to meet EN61000-3-2 Small package 6.00 x 3.5 x 1.5 inches Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial approved to UL1950, IEC950, CSA22.2 No. 950 and EN60950. Medical approved to UL2601-1, IEC601-1, CSA22.2 No. 601.1, EN60601-1 marked to LVD SPECIFICATIONS: Ac Input Remote Sense 90-264 Vac, 47-63 Hz single phase. Provided as a standard feature on V1 of all models. Input Current Temperature Range Maximum input current 2A at 90 Vac, 60 Hz with full rated load. 0 to 50 °C at full rated output power. For operation above 50 °C, Input current harmonic content meets the requirements of derate output power and current by 2.5 % per °C. IEC1000-3-2. Active circuitry provides high power factor as Altitude listed at .96 min., .99 typical. All data taken with full output Operating: -500 to 10,000 ft. MSL loading. Non-Operating -500 to 40,000 ft MSL DC Output Power Shock and Vibration 125 W with 150 LFM of air, 50 W convection cooled, 80 W All models are designed to meet the following specifications; convection cooled with unit mounted to min. 12 x 12 x .125 in. Random Vibration - thick aluminim plate. Peak ratings are for 60 s maximum 2 duration, 10% duty cycle. With optional cover installed,125 W, Operating: 0.003 g /Hz, 1.5 g overall, 3 axes, 10 min. / axis rms 2 200 LFM airflow is required(-C suffix). Non-Operating: 0.026 g /Hz, 5.0 g overall, 3 axes, 1 hr. / axis rms Inrush Current Shock - Inrush 240 Vac is less than 37 A, averaged over the first ac Operating: Half-sine, 20 g , 10 ms, 3 axes, 6 shocks total pk half-cycle under cold start conditions. Limiting provided by Non-Operating: Half-sine, 40 g , 10 ms, 3 axes, 6 shocks total internal thermistors. pk Input Protection EMI/EMC Compliance Internal ac fuse provided on all models. Fuse does not blow on All models include built-in EMI filtering to meet the EMC overload or short circuit — fuse blows only if a catastrophic requirements below. failure occurs in the unit. EMI SPECIFICATIONS COMPLIANCE LEVEL Efficiency Conducted Emissions-GPFC125 EN55022, Class B; FCC Class B 72 to 85% at full rated load. Depending upon model and load Conducted Emissions-GPFM125 EN55011,Class B; FCC Class B distribution. Static Discharge EN61000-4-2, 6 kV contact 8 kV air Minimum Load RF Field Susceptibility EN61000-4-3, 3V/meter Supply will function with no load on any output. To maintain Fast Transients / Bursts EN61000-4-4, 2 kV, 5 kHz regulation with full load on V2, 3 and 4 output V1 requires a Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. minimum load of (2A + V4 current). Lower minimum load may be Conducted RF Susceptibility EN61000-4-6, 3V obtained if less then full load is drawn from auxiliary outputs. Voltage Sags & Surges EN61000-4-11 Line Frequency Harmonics EN61000-3-2 Class A Overload Protection Fully protected against short circuit and output overload. Total Commercial Safety Approvals output power limited to approximately 150 Watts. Cycling type All models are approved to UL1950, CSA22.2 No. 950-95, limits on output 1, 2 & 3, linear fold back on output 4. Recovery IEC950, EN60950. CB certificate available. Exceeds FCC and after fault is automatic. CISPR22 Class B conducted emissions requirement Overvoltage Protection Medical Safety Approvals Built in on all models - See Output table for individual model All models are Certified to be in compliance with the applicable output limits. requirements of UL2601, CSA 22.2 No. 601.1-M90, IEC 601-1 Output Noise (1988), EN 60601-1: 1990. CB certificate available. 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Leakage Current Transient Response The maximum leakage current is as follows: 500 ms typical response time for return to within 0.5% of final value for a 50% load step change, ∆i/∆t< 0.2 A ms. Maximum Test Condition Normal Single Fault voltage deviation is 3.5%. 132 Vac @ 60 Hz input 70 µA 120 µA Temperature Coefficient 264 Vac @ 50 Hz input 130 µA 240 µA 0.03% / °C typical on all outputs. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 FAX 805-487-8911 www.condorpower.com 52 GPFC125 Commercial/GPFM125 Medical 125 Watt Multiple Output Commercial Medical Voltage Output Voltage Output Qutput Voltage OVP Total Ripple/ Model Model Output No. Current (A) Current (B) Adjustment Regulation Noise GPFC125A GPFM125A 1 +5 V 9 A 16 A ±5% 6.2 ±0.6 V 1% 1% 2 +12 V 4 A 7 A ±5% -- 1% 1% 312 V (C) 2.5 A 4 A -- -- 1% 1% 4-12 V 0.3 A 1 A -- -- 1% 1% GPFC125B GPFM125B 1 +5 V 9 A 16 A ±5% 6.2 ±0.6 V 1% 1% 2 +12 V 4 A 7 A ±5% -- 1% 1% 312 V (C) 2.5 A 4 A -- -- 1% 1% 4-5 V 0.3 A 1 A -- -- 1% 1% GPFC125C GPFM125C 1 +5 V 9 A 16 A ±5% 6.2 ±0.6 V 1% 1% 2 +12 V 4 A 7 A ±5% -- 1% 1% 315 V (C) 2.5 A 4 A -- -- 1% 1% 4-15 V 0.3 A 1 A -- -- 1% 1% GPFC125D GPFM125D 1 +5 V 9 A 16 A ±5% 6.2 ±0.6 V 1% 1% 2 +24 V 3 A 4.5 A ±5% -- 1% 1% 312 V (C) 2.5 A 4 A -- -- 1% 1% 4-12 V 0.3 A 1 A -- -- 1% 1% GPFC125E GPFM125E 1 +5 V 9 A 16 A ±5% 6.2 ±0.6 V 1% 1% 2 +24 V 3 A 4.5 A ±5% -- 1% 1% 315 V (C) 2.5 A 4 A -- -- 1% 1% 4-15 V 0.3 A 1 A -- -- 1% 1% GPFC125F GPFM125F 1 +5 V 9 A 16 A ±5% 6.2 ±0.6 V 1% 1% 2 +15 V 3.5 A 6 A ±5% -- 1% 1% 315 V (C) 2.5 A 4 A -- -- 1% 1% 4 - 5 V 0.3 A 1 A -- -- 1% 1% 9 A GPFC125G GPFM125G 1+5 V 16 A ±5% 6.2 ±0.6 V 1% 1% 2 +3.3 V 7 A 10 A ±5% 4.2 ±0.6 V 1% 2% 312 V (C) 2.5 A 4 A -- -- 1% 1% 4-12 V 0.3 A 1 A -- -- 1% 1% GPFC125H GPFM125H 1 +3.3 V 9 A 16 A ±5% 4.2 ±0.6 V 1% 2% 2 +5 V 4 A 7 A ±5% 6.2 ±0.6 V 1% 1% 312 V (C) 2.5 A 4 A -- -- 1% 1% 4-12 V 0.3 A 1 A -- -- 1% 1% Notes: A. Continuous rating for unrestricted convection cooling. B. Peak rating or continuous rating with 150 LFM air cooling. C. Output 3 is isolated. Can be connected as + or - output. GPFC125/GPFM125 MECHANICAL SPECIFICATIONS INPUT: J1 AMP P.C.B. HEADER P/N 640445-5 PIN 1) AC LINE PIN 2) N/C PIN 3) AC NEUTRAL PIN 4) N/C PIN 5) AC GROUND MATING CONNECTOR AMP P/N HOUSING 640250-5 CONTACT 770476-1 SIGNALS: J2 AMP P.C.B. HEADER P/N 640456-4 MATING CONNECTOR P/N 640440-4 PIN 1) POWER FAIL PIN 2) -SENSE PIN 3) +SENSE PIN 4) COMMON OUTPUT: J3 AMP P.C.B HEADER P/N 1-640445-3 PIN 1) -V4OUT PIN 2-4) +V1OUT PINS 5-9) COMMON PIN 10,11) +V2 OUT PIN 12) +V3OUT PIN 13) -V3RTN MATING CONNECTOR AMP P/N HOUSING 1-640250-3 CONTACT 770476-1 OPTIONAL COVER P/N 08-30466-2125 WEIGHT: 1.25 LBS [ .56 KG] Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 53
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the GPFM125B have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods