Elite.Parts chervon right Manufacturers chervon right S chervon right SL POWER / CONDOR POWER chervon right GLC65A
About product Specifications Features Datasheet FAQ

SL POWER / CONDOR POWER GLC65A

Image of SL POWER / CONDOR POWER GLC65A

Description

SL Power / Condor Power GLC65A Power Supply. Open Frame | 65 W | 5V, +-12V DC Triple Output

Part Number

GLC65A

Price

Request Quote

Manufacturer

SL POWER / CONDOR POWER

Lead Time

Request Quote

Category

POWER

Specifications

Efficiency

80%

Mounting Type

Chassis Mount

Number of Outputs

3

Operating Temperature

0°C ~ 50°C

Output Current (Channel 1)

7 A

Output Current (Channel 2)

3 A

Output Current (Channel 3)

2.5 A

Output Voltage (Channel 1)

5 VDC

Output Voltage (Channel 2)

12 VDC

Output Voltage (Channel 3)

- 12 VDC

Power (Watts)

65W

Power (Watts) - Max

65W

Size/Dimension

5.00" L x 3.00" W x 1.25" H (127.0mm x 76.2mm x 31.8mm)

Voltage - Input

90 ~ 264VAC

Voltage - Output

5V, ±12V

Features

Datasheet

pdf file

ba700dd8-e0ea-410b-9e8a-9bd93825e5f7

283 KiB

Extracted Text

GLC65 Commercial/GLM65 Medical 65 Watt Multiple Output Global Performance Switchers MULTIPLE OUTPUT GLOBAL PERFORMANCE SWITCHERS Summary: • 65 Watt Wide Range Input • High Efficiency (Up to 90%) • Universal input 90-264 Vac • 2-year warranty • Also available in single outputs • Conducted EMI complies with FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) • Exempt from line harmonics standard EN61000-3-2 • Commercial Approved to UL1950, CSA-C22.2 No. 950, • Medical Approved to UL2601-1, CSA 22.2 No. 601.1, and EN60601-1• Medical Approved to UL2601-1, CSA 22.2 No. 601.1, • RoHS Compliant (G suffix) • marked to LVD SPECIFICATIONS Ac Input Minimum Load 90-264 Vac, 47-63 Hz single phase. No minimum load required on any output. However, regulation limits may be exceeded if extreme conditions are applied. Contact factory for assistance. Output Power Total continuous output power is 60 W, 75 W peak for 60 s 10% duty cycle. Temperature Coefficient: 0.03%°C typical on all outputs. Total continuous rating with 150 LFM of air is 70 W. Voltage Adjustment Input Current Units provided with one potentiometer capable of adjusting all 3 outputs a mini- Units are exempt from input current harmonic requirements of EN61000-3-2 mum of +/- 5% from nominal setting. when output power is less than 62W. Maximum input current at minimum input voltage and output overload will be less than 2.0 A. EMI / EMC Compliance: Inrush Current All models include built-in EMI filtering to meet EMC requirements of IEC601-1-2. Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over PERFORMANCE EMC STANDARD the first ac half-cycle under cold start conditions will not exceed 37 A. Input Protection Conducted Emissions GLC65 EN55022 Class B; FCC Class B Internal AC fuse provided on all units. Designed to blow only if a catastrophic Conducted Emissions GLM65 EN55011 Class B; FCC Class B failure occurs in the unit -- Fuse does not blow on short circuit or unsustained Static Discharge EN61000-4-2, Level 3 overload. RF Field Susceptibility EN61000-4-3, Level 3 Fast Transients/Bursts EN61000-4-4, Level 3 Holdup Time Surge Susceptibility EN61000-4-5, Level 3 Output voltage stays within regulation for 20 ms from loss of ac input at 65 W Conducted RF Susceptibility EN61000-4-6, 3V, 80% load, from 120 Vac input. Voltage Sags & Surges EN61000-4-11 Efficiency Line Frequency Harmonics EN61000-3-2 Class A (>62Wout) 80% minimum. Exempt (<62Wout) Overload Protection GLC65 Commercial - Safety Fully protected against short circuit and output overload. Short circuit SL Power Electronics Corp declares under our sole responsibility that all models protection is cycling type power limit and will automatically recover after are in conformity with the applicable requirements of EN60950 following the removal of fault. provisions of the Low Voltage Directive 73/23/EEC. All models are approved to Overvoltage Protection UL1950 (with no D3 deviations), CSA22.2 No. 950-95 3rd edition, Level 3, IEC950, Built in with firing point set. OVP firing reduces output to less than 50% of EN60950. CB certificate available. nominal voltage in less than 50 ms. Commercial Leakage Current Output Noise Less then 500 μA @ 120 Vac. Less then 1.2 mA @ 240 Vac. 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply with load GLM65 Medical - Safety terminated with 1μF capacitor. Approvals: All models are certified to be in compliance with the applicable require- ments of UL2601-1, CSA 22.2 No. 601.1, IEC 601-1 (1988), EN 60601-1: 1990. Transient Response Main Output - 500 μs typical response time for return to within 0.5% of final Medical Leakage Current value for a 50% load step within the regulation limits of minimum and maxi- 80 μA under normal conditions (132 Vac @ 60 Hz). Maximum under single fault mum load, ∆i/∆t< 0.2 A/μs. Maximum voltage deviation is 3.5%. conditions (264 Vac @ 60 Hz) is 180 μA. O All specifications are typical at nominal input, full load at 25 C unless otherwise stated Commercial Medical Output Output Total V1 Adjustment OVP Set- Ripple/ Model Model Output No. Output Maximum (A) Maximum (B) Regulation (E) Note (C) point Noise GLC65A GLM65A 1 +5.0 V 7 A 9A 2% ± 5% 6.2 ± 0.6 V 1% 2 +12 V 3 A 5 A 5% — — 1% 3 -12 V 2.5 A 4 A 6% — — 1% GLC65B GLM65B 1 +5.1 V 7 A 9 A 2% ± 5% 6.2 ± 0.6 V 1% 2 +15 V 2.5 A 4 A 4% — — 1% 3 -15 V 2 A 3 A 5% — — 1% GLC65D GLM65D 1 +5.0 V 7 A 9 A 2% ± 5% 6.2 ± 0.6 V 1% 2 +24 V 1.5 A 2.5 A 3% — — 1% 3 -12 V 2.5 A 4 A 6% — — 1% GLC65E GLM65E 1 +5.0 V 7 A 9 A 2% ± 5% 6.2 ± 0.6 V 1% 2 +24 V 1.5 A 2.5 A 3% — — 1% 3 +12 V 2.5 A 4 A 6% — — 1% GLC65G GLM65G 1 +5.0 V 5 A 8 A 3% ± 5% 6.2 ± 0.6 V 1% 2 +3.3 V 4 A 5 A 3% — — 1% 3 +12 V 2.5 A 4 A 6% — — 1% GLC65H GLM65H 1 +3.3 V 5 A 8 A 3.5% ± 5% 4.3 ± 0.8 V 1% 2 +5.0 V 4 A 6 A 4.5% — — 1% 3 +12 V 2.5 A 3 A 6% — — 1% Notes: A. Continuous individual output ratings for unrestricted convection cooling. Combination of individual output loads must not exceed total power rating. B. Peak rating for 60 s 10% duty cycle or continuous rating 150 LFM forced air cooling. C. Adjustment on V1 varies all outputs simultaneously (1% on V1 @ 1% on V2 & V3). D. Total combined current of V1 & V2 not to exceed 12 A. Combination of individual output loads must not exceed total power rating. E. Total regulation is defined as maximum deviation from the initial set point. With all other outputs at 50% load, output under test can be varied from 0 to 100% load and varied to any ac line voltage. Initial set point is 1% on V1, 2% on V2 and 3% on V3 F. Add “G” suffix to model number for RoHS compliant model. GLC65 MECHANICAL SPECIFICATIONS 1.20 30.28 A. Units should be allowed to warm up/operate under non-condensing con- ditions before application of power. Derate output current and total output power by 2.5% per °C above 50°C. For operation in a confined space, moving air may be required. Under all conditions, the cooling vs. load profile should be such that heat sinks and/or heatsink temperatures do not exceed 90 °C ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING for extended periods. Temperature (A) 0 TO 50°C -40 to +85°C B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogo- Humidity (A) 0 to 95% RH 0 to 95% RH nal axes, total 6 shocks. Shock (B) 20 g 40 g pk pk C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, Altitude -500 to 10,000 ft -500 to 40,000 ft 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-op- erating. 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms’ rms’ SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 09/10/08. Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the GLC65A have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

SL Power / Condor Power GLC75C Power Supply. Open Frame | Commercial | 5.1V, 12V, +-15V DC Quad Outp...

product

SL Power/Condor Power GLC75D Switch - 75 Watt Single Output Global Performance Switchers

product

SL Power / Condor Power GLC75J Power Supply. Open Frame | Commercial | 75 W | 5.1V, +-12V, 5V DC Qua...

product

SL Power / Condor Power GLD140F Power Supply. Open Frame | Medical | 140 W | 5V, 15V, +-12V DC Quad ...

product

SL Power / Condor Power GLD140G Power Supply. Open Frame | Medical | 140 W | 5V, 3.3V, +-12V Quad Ou...

product

SL Power / Condor Power GLM110-12 Power Supply. Open Frame | Medical | 110 W | 12 VDC @ 6.3A Single ...