SL POWER / CONDOR POWER GLC50A
Specifications
Ac Input
90-264 Vac, 47-63 Hz single phase.
Efficiency
70-85% at full rated load, nominal input voltage, depending on model and load distribution.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions requirements: Conducted Emissions GLC:EN55022 Class B; FCC Class B; Conducted Emissions GLM:EN55011 Class B; FCC Class B; Static Discharge:EN61000-4-2, 6 kV contact, 8 kV air; RF Field Susceptibility:EN61000-4-3, 3 V/meter; Fast Transients/Bursts:EN61000-4-4, 2 kV, 5 kHz; Surge Susceptibility:EN61000-4-5, 1 kV diff., 2 kV com.
Hold-Up Time
15 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.5 A
Input Protection
Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit—fuse does not blow on overload or short circuit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A.
Minimum Load
Operating without minimum load will not degrade reliability, but regulation may be affected. Multiple output models require 20% minimum load on V1 for proper regulation. Single models require 5% minimum load.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply.
Output Power
50 W continuous, 60 W peak. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits.
Output Regulation
To maintain specified regulation on multi-output models, output #1 load power must be at least 1/5th of, and not greater than 5 times output #2 load power.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on outputs 1 & 2; foldback type on output 3. Recovery after fault is automatic. See output ratings chart for additional notes or conditions.
Temperature Coefficient
0.03%/°C typical on all outputs.
Transient Response
500 µs typical response time for return to within 0.5% of final value for a 50% load step change. ?i/?t
Voltage Adjustment
Built-in potentiometer adjusts V1 ±5%.
Features
- Compact (4.25" x 2.50" x 1.25"; meets 1U applications)
- Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models)
- Cost-effective power source
- Overload and overvoltage protection
- Universal input 90-264 Vac
Datasheet
Extracted Text
GLC50 Commercial/GLM50 Medical 50 Watt Output Global Performance Switchers FEATURES: Cost-effective power source Universal input 90-264 Vac 2-year warranty Compact (4.25" x 2.50" x 1.25"; meets 1U applications) Overload and overvoltage protection Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial UL1950, CSA22.2 No. 950 and IEC 950, EN60950 approvals Medical UL2601, CSA22.2 No. 601, IEC601-1, EN60601-1 SPECIFICATIONS:marked to LVD Ac Input Temperature Coefficient 90-264 Vac, 47-63 Hz single phase. 0.03%/°C typical on all outputs. Input Current Output Noise Maximum input current at 120 Vac, 60 Hz with full rated 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential output load: 1.5 A mode. Measured with noise probe directly across output terminals of the power supply. Hold-Up Time 15 ms minimum from loss of ac input at full load, nominal Transient Response line (115 Vac). 500 µs typical response time for return to within 0.5% of final value for a 50% load step change. Δi/Δt<0.2 A/µs. Output Power Maximum voltage deviation is 3.5%. Startup/shutdown 50 W continuous, 60 W peak. Peak ratings are for 60 s overshoot less than 3%. maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation Voltage Adjustment limits. Built-in potentiometer adjusts V1 ±5%. Output Regulation EMI/EMC Compliance To maintain specified regulation on multi-output models, All models include built-in EMI filtering to meet the output #1 load power must be at least 1/5th of, and not following emissions requirements: greater than 5 times output #2 load power. EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions GLC EN55022 Class B; FCC Class B Overload Protection Conducted Emissions GLM EN55011 Class B; FCC Class B Fully protected against short circuit and output overload. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Short circuit protection is cycling type power limit on RF Field Susceptibility EN61000-4-3, 3 V/meter outputs 1 & 2; foldback type on output 3. Recovery after Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz fault is automatic. See output ratings chart for additional Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. notes or conditions. Commercial Leakage Current Efficiency 160 µA 254 Vac @ 60 Hz input (with no deviations). 70-85% at full rated load, nominal input voltage, depend- ing on model and load distribution. Commercial Safety All GLC models are approved to UL1950, CSA22.2 No. Minimum Load 234 Level 3, IEC950 and EN60950. Operating without minimum load will not degrade reliability, but regulation may be affected. Multiple output Medical Leakage Current models require 20% minimum load on V1 for proper 100 µA 264 Vac @ 60 Hz input (normal conditions). regulation. Single models require 5% minimum load. Medical Safety Input Protection All GLM models are approved to UL2601, CSA22.2 No. Internal ac fuse provided. Designed to blow only if a 601, IEC601-1 and EN60601-1. catastrophic failure occurs in the unit—fuse does not blow on overload or short circuit. Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 FAX 805-487-8911 www.condorpower.com 30 GLC50 Commercial/GLM50 Medical 50 Watt Multiple Output Commercial Medical Total Minimum Load Model Model Output No. Output Current OVP Setpoint Noise P-P Regulation (A) (B) GLC50A GLM50A 1 +5.05 V 4 A 0V .8 A6V .2 ± 0.6 50 m 2% 2 +12 V 2.5 A 120 mV +10%, -5% 3 -12 V 0.2 A 120 mV 3% GLC50B GLM50B 1 + 5.1 V 4 A 0V .8 A6V .2 ± 0.6 50 m 2% 2 +15 V 2.5 A 150 mV +10%, -5% 3 -15 V 0.2 A 150 mV 3% GLC50D GLM50D 1 +5.1 V 4 A 0V .8 A6V .2 ± 0.6 50 m 2% 2 +24 V 1.5 A 240 mV +10%, -5% 3 -12 V 0.2 A 120 mV 3% GLC50G GLM50G 1 +3.3 V 4 A 0V .8 A4V .2 ± 0.6 33 m 2% 2 +12 V 2.5 A 120 mV +10%, -5% 3 -12 V 0.2 A 120 mV 3% GLC50-3.3 GLM50-3.3 1V3A .3 804V .2 ± 0.6V6% 6 m 2 GLC50-5 GLM50-5 1V5A .1 806V .2 ± 0.6V7% 5 m 2 GLC50-12 GLM50-12 1V1A 2 40 .2 1V 4 ± 1.1V1% 20 m 2 GLC50-15 GLM50-15 1V1A 5 30 .3 1V 8.5 ± 1.5V1% 50 m 2 GLC50-24 GLM50-24 1V2A 4 20 .1 2V 8 ± 2.5V2% 40 m 2 GLC50-28 GLM50-28 1V2A 8 10 .8 3V 4.5 ± 2.8V2% 80 m 2 GLC50-48 GLM50-48 1V4A 8 10 .1 5V 4 ± 3.0V4% 80 m 2 A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. T o maintain specified regulation on multi-output models, output #1 load power must be at least 1/5th of, and not greater than 5 times output #2 load power. GLC50/GLM50 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o o T0 emperature (A) 0 to 5C5 -40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions HH umidity (A)0H to 95% R 0 to 95% R before application of power. derate output current and total output power by 2.5% per °C above 50°C. Sg hock (B) 20 40 g pk pk B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 At ltitude-t 500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz total 6 shocks. rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 31
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the GLC50A have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
Related Products

SL Power / Condor Power GLC75C Power Supply. Open Frame | Commercial | 5.1V, 12V, +-15V DC Quad Outp...

SL Power / Condor Power GLC75J Power Supply. Open Frame | Commercial | 75 W | 5.1V, +-12V, 5V DC Qua...

SL Power / Condor Power GLD140F Power Supply. Open Frame | Medical | 140 W | 5V, 15V, +-12V DC Quad ...

SL Power / Condor Power GLD140G Power Supply. Open Frame | Medical | 140 W | 5V, 3.3V, +-12V Quad Ou...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods