RED LION CONTROLS T4811102

Image of RED LION CONTROLS T4811102

Description

Red Lion Controls T4811102 with 3 Relay Output and RS485

Part Number

T4811102

Price

Request Quote

Manufacturer

RED LION CONTROLS

Lead Time

Request Quote

Category

CONTROL DEVICE

Datasheet

pdf file

Red Lion-T4811102-datasheet1-726434498.pdf

576 KiB

Extracted Text

Bulletin No. T48-G Drawing No. LP0332 Released 2/06 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL T48 - 1/16 DIN TEMPERATURE CONTROLLER O PID CONTROL WITH REDUCED OVERSHOOT O ON DEMAND AUTO-TUNING OF PID CONTROL SETTINGS O NEMA 4X/IP65 BEZEL O DUAL LED DISPLAYS FOR SIMULTANEOUS INDICATION OF TEMPERATURE AND SETPOINT O STATUS INDICATORS FOR OUTPUTS AND CONTROL MODES O ACCEPTS 10 TYPES OF SENSOR INPUTS (Thermocouple or RTD) O OPTIONAL HEATER CURRENT MONITOR AND HEATER BREAK ALARM O OPTIONAL DUAL ALARM OUTPUTS O OPTIONAL TWO LINEAR DC OUTPUTS (0 to 10 V, 0/4 to 20 mA) O MANUAL/AUTOMATIC CONTROL MODES O SETPOINT RAMPING FOR PROCESS STARTUP O OPTIONAL TRIAC OUTPUT O PROGRAMMABLE USER INPUT (Digital) FOR ADDED FLEXIBILITY O SECOND SETPOINT SETTING O SENSOR ERROR COMPENSATION (Offset) AND BREAK O OPTIONAL REMOTE SETPOINT INPUT (0/4 to 20 mA) DETECTION O OPTIONAL RS485 SERIAL COMMUNICATIONS O HEATING AND OPTIONAL COOLING OUTPUTS O PC SOFTWARE AVAILABLE FOR CONTROLLER CONFIGURATION O PARAMETER SECURITY VIA PROGRAMMABLE LOCKOUTS UL Recognized Component, O FIELD REPLACEABLE OUTPUT BOARD File # E156876 (Relay or Logic/SSR Drive) DESCRIPTION The T48 Controller accepts signals from a variety of temperature sensors Dual 4-digit displays allow viewing of the process temperature and setpoint (thermocouple or RTD elements), precisely displays the process temperature, simultaneously. Front panel indicators inform the operator of the controller and and provides an accurate output control signal (time proportional or linear DC) output status. On many models the main control output and the alarm outputs to maintain the process at the desired temperature. The controller’s are field replaceable. comprehensive yet simple programming allows it to meet a wide variety of Optional alarm(s) can be configured to activate according to a variety of actions application requirements. (Absolute HI or LO, Deviation HI or LO, Band IN or OUT, and Heater Current The controller operates in the PID control mode for both heating and cooling, Break) with adjustable hysteresis. A standby feature suppresses the alarm during with on-demand auto-tune, which will establish the tuning constants. The PID power-up until the temperature stabilizes outside the alarm region. The second tuning constants may be fine-tuned by the operator at any time and then locked alarm can be configured as a secondary PID output (heat/cool applications). out from further modification. The controller employs a unique overshoot Optional Main Linear DC output (10 V or 20 mA) can be used for control or suppression feature, which allows the quickest response without excessive temperature re-transmission purposes. Programmable output update time overshoot. The unit can be transferred to operate in the manual mode, providing reduces valve or actuator activity. The output range can be scaled independent the operator with direct control of the output. The controller may also be of the input range. programmed to operate in the ON/OFF control mode with adjustable hysteresis. Optional Second Linear DC output (10 V or 20 mA) provides an independent A second setpoint is available on select models to allow quick selection of a temperature re-transmission, while the main Linear DC output is being used for different setpoint setting. control. The output range can be scaled independent of the input range. Optional Heater Current Monitor provides a direct readout of process heater current. An alarm can be programmed to signal when the heater has failed. This provides early warning of system failure before product quality is affected. CAUTION: Risk of Danger. CAUTION: Risk of electric shock. Read complete instructions prior to installation and operation of the unit. DIMENSIONS In inches (mm) PANEL CUT-OUT 1 Optional Remote Setpoint input (0/4 to 20 mA) allows for cascade control Cold junction compensation: Less than ±1°C (±1.5°C max), error over 0 loops, where tighter control is required; and allows for remotely driven setpoint to 50°C max. ambient temperature range. Defeated for Linear mV signal from computers or other similar equipment. Straightforward end point indication mode. scaling with independent filtering and local/remote transfer option expand the Resolution: 1° for all types, or 0.1° for T, E, J, K, and N only. controller’s flexibility. WIRE COLOR TC TYPE RANGE The optional RS485 serial communication interface provides two-way ANSI BS 1843 communication between a T48 and other compatible equipment such as a -200 to +400°C blue (+) white (+) T printer, PLC, HMI, or a host computer. In multipoint applications (up to -328 to +752°F red (-) blue (-) thirty-two), the address number of each T48 on the line can be programmed -200 to +750°C violet (+) brown (+) E from 0 to 99. Data from the T48 can be interrogated or changed, and alarm -328 to +1382°F red (-) blue (-) -200 to +760°C white (+) yellow (+) output(s) may be reset by sending the proper command code via serial J -328 to 1400°F red (-) blue (-) communications. PC software, SFCRM, allows for easy configuration of -200 to +1250°C yellow (+) brown (+) controller parameters. These settings can be saved to disk for later use or used K -328 to +2282°F red (-) blue (-) for multi-controller down loading. On-line help is provided within the software. 0 to 1768°C black (+) white (+) R The unit is constructed of a lightweight, high impact plastic case with a tinted +32 to +3214°F red (-) blue (-) front panel. The front panel meets NEMA 4X/IP65 specifications when properly 0 to 1768°C black (+) white (+) S installed. Multiple units can be stacked horizontally or vertically. Modern +32 to 3214°F red (-) blue (-) surface-mount technology, extensive testing, plus high immunity to noise +149 to +1820°C grey (+) B no standard +300 to +3308°F red (-) interference makes the controller extremely reliable in industrial environments. -200 to +1300°C orange (+) orange (+) N -328 to +2372°F red (-) blue (-) SAFETY SUMMARY mV -5.00 to +56.00 no standard no standard All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to 7. RTD INPUT: 2 or 3 wire, 100 Ω platinum, alpha = 0.00385 (DIN 43760), prevent damage to either the instrument or equipment connected to it. If alpha = 0.0039162 equipment is used in a manner not specified by the manufacturer, the protection Excitation: 150 µA typical provided by the equipment may be impaired. Resolution: 1 or 0.1 degree Do not use the T48 to directly command motors, valves, or other actuators not Lead Resistance: 15 Ω max. per input lead equipped with safeguards. To do so can be potentially harmful to persons or RTD TYPE RANGE equipment in the event of a fault to the controller. An independent and redundant -200 to +600°C temperature limit indicator with alarm outputs is strongly recommended. 385 -328 to +1100°F -200 to +600°C SPECIFICATIONS 392 -328 to +1100°F 1. DISPLAY: Dual 4-digit OHMS 1.0 to 320.0 Upper Temperature Display: 0.4" (10.2 mm) high red LED 8. INDICATION ACCURACY: ±(0.3% of Span +1°C.) includes NIST Lower Auxiliary Display: 0.3" (7.6 mm) high green LED Display Messages: conformity, cold junction effect and A/D conversion errors at 23°C after 20 “OLOL” - Appears when measurement exceeds + sensor range. min. warm-up. “ULUL” - Appears when measurement exceeds - sensor range. 9. USER INPUT: Internally pulled up to +5 VDC (1 MΩ). “OPEN” - Appears when open sensor is detected. V = 5.25 VDC V = 0.85 V max., V = 3.65 V min., IN MAX , IL IH “SHrt” - Appears when shorted sensor is detected (RTD only) I = 1µA max. OFF “...” - Appears when display values exceed + display range. Response Time: 120 msec max. “-..” - Appears when display values exceed - display range. Functions: Program Lock Integral Action Lock LED Status Annunciators: Auto/Manual Mode Select Setpoint Ramp Enable %P - Lower auxiliary display shows power output in (%). MN - Flashing: Controller is in manual mode. Reset Alarms Setpoint 1/Setpoint 2 Select On: Local Setpoint (Remote Setpoint option) Local/Remote Setpoint Select Serial block print Off: Remote Setpoint DV - Lower auxiliary display shows deviation (error) from 10. CONTROL AND ALARM OUTPUTS: (Heating, Cooling or Alarm) temperature setpoint or shows heater current. Relay outputs with Form A contacts: O1 - Main control output is active. Contact Rating: 3 A @ 250 VAC or 30 VDC (resistive load) A1 - Alarm #1 is active (for A1 option.). 1/10 HP @ 120 VAC (inductive load) A2 - Alarm #2 is active OR Life Expectancy: 100,000 cycles at max. load rating. - Cooling output (O2) is active (Decreasing load and/or increasing cycle time, increases life 2. POWER: expectancy.) AC Versions: 85 VAC min. to 250 VAC max., 50 to 60 Hz, 8 VA max. Logic/SSR Drive Outputs: DC Versions: Rating: 45 mA @ 4 V min., 7 V nominal DC Power: 18 to 36 VDC; 7 W Triac Outputs: AC Power: 24 VAC ± 10%; 50 to 60 Hz, 9 VA Type: Isolated, Zero Crossing Detection 3. CONTROLS: Four front panel push buttons for modification and setup of Rating: controller functions and one external input user for parameter lockout or other functions. Voltage: 120/240 VAC 2 4. MEMORY: Nonvolatile E PROM retains all programmable parameters and Max. Load Current: 1 Amp @ 35°C values. 0.75 Amp @ 50°C 5. MAIN SENSOR INPUT: Min Load Current: 10 mA Sample Period: 100 msec Offstate Leakage Current: 7 mA max. @ 60 Hz Response Time: Less than 300 msec typ., 400 msec max. (to within 99% of Operating Frequency: 20 to 400 Hz final value w/step input; typically, response is limited to response time of Protection: Internal transient snubber probe) 11. MAIN CONTROL: Failed Sensor Response: Control: PID or ON/OFF Main Control Output(s): Programmable preset output Output: Time proportioning or Linear DC Display: “OPEN” Cycle time: Programmable Alarms: Upscale drive Auto-tune: When selected, sets proportional band, integral time, and Normal Mode Rejection: 40 dB @ 50/60 Hz (improves with increased derivative time values. digital filtering.) Probe Break Action: Programmable Common Mode Rejection: Greater than 120 dB, DC to 60 Hz 12. ALARMS: 1 or 2 alarms (optional) Protection: Input overload 120 VAC max. for 15 seconds max. Modes: Absolute high acting 6. THERMOCOUPLE INPUT: Absolute low acting Types: T, E, J, K, R, S, B, N, Linear mV, software selectable Deviation high acting Input Impedance: 20 MΩ all types Deviation low acting Lead resistance effect: 0.25 µV/Ω Inside band acting 2 Outside band acting Operating Range: 0 to 50°C Heater break alarm Storage Range: -40 to 80°C Reset Action: Programmable; automatic or latched Span Drift (max.): 130 ppm/°C, main input Standby Mode: Programmable; enable or disable Zero Drift (max.): 1µV/°C, main input Hysteresis: Programmable Operating and Storage Humidity: Probe Break Action: Upscale 85% max. relative humidity (non-condensing) from 0°C to 50°C. Annunciator: LED backlight for “A1”, “A2” Altitude: Up to 2000 meters 13. COOLING: Software selectable (overrides alarm 2) 19. ISOLATION BREAKDOWN RATINGS: Control: PID or ON/OFF AC line with respect to all Inputs and outputs: 250 V working (2300 V for Output: Time Proportioning 1 minute). Cycle time: Programmable Main input with respect to Analog Outputs, Remote Setpoint Input, Proportional Gain Adjust: Programmable Heater Current Input: 50 V working (2300 V for 1 minute). Heat/Cool Deadband Overlap: Programmable All other inputs and outputs with respect to relay contacts: 2000 VAC 14. MAIN AND SECOND LINEAR DC OUTPUT: (optional) Not isolated between Analog Outputs, Remote Setpoint and Heater Current Main: Control or Re-transmission, programmable update rate from 0.1 sec to commons. 250 sec 20. CERTIFICATIONS AND COMPLIANCES: Second: Re-transmission only, fixed update rate of 0.1 sec SAFETY * Accuracies are expressed as ± percentages after 20 minutes warm-up. Output UL Recognized Component, File #E156876, UL873, CSA 22.2 No. 24 Recognized to U.S. and Canadian requirements under the Component OUTPUT ** ACCURACY * ACCURACY * COMPLIANCE RESOLUTION RANGE (18 to 28°C) (0 to 50°C) Recognition Program of Underwriters Laboratories, Inc. 0.10% of FS 0.30% of FS Type 4X Enclosure rating (Face only), UL50 0 to 10 V 10k ohm min. 1/3500 + 1/2 LSD + 1/2 LSD IECEE CB Scheme Test Certificate # UL1369-156876/USA, 0.10% of FS 0.30% of FS CB Scheme Test Report # 96ME50224-040396 0 to 20 mA 500 ohm max. 1/3500 + 1/2 LSD + 1/2 LSD Issued by Underwriters Laboratories, Inc. 0.10% of FS 0.30% of FS 4 to 20 mA 500 ohm max. 1/2800 IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment + 1/2 LSD + 1/2 LSD for measurement, control, and laboratory use, Part 1. accuracy is specified in two ways: Accuracy over an 18 to 28°C range at 10 IP65 Enclosure rating (Face only), IEC 529 to 75% RH environment; and accuracy over a 0 to 50°C range at 0 to 85% ELECTROMAGNETIC COMPATIBILITY RH (non-condensing) environment. Accuracy over the wide temperature Notes: range reflects the temperature coeffecient of the internal circuitry. Immunity to EN 50082-2 ** Outputs are independently jumper selectable for either 10 V or 20 mA. The Electrostatic discharge EN 61000-4-2 Level 2; 4 Kv contact output range may be field calibrated to yield approximately 10% overrange Level 3; 8 Kv air and a small underrange (negative) signal. 1 Electromagnetic RF fields EN 61000-4-3 Level 3; 10 V/m 15. REMOTE SETPOINT INPUT: (optional) 80 MHz - 1 GHz Input type: Fast transients (burst) EN 61000-4-4 Level 4; 2 Kv I/O 0/4 to 20 mA Level 3; 2 Kv power Input Resistance: 10 Ω 2 RF conducted interference EN 61000-4-6 Level 3; 10 V/rms Overrange: -5% to 105% 150 KHz - 80 MHz Overload: 100 mA (continuous) Power frequency magnetic fields EN 61000-4-8 Level 4; 30 A/m Scale Range: -999 to 9999 degrees or -99.9 to 999.9 degrees. Simulation of cordless telephones ENV 50204 Level 3; 10 V/m Resolution: 1 part in 10,000. 900 MHz ± 5 MHz Accuracy: 200 Hz, 50% duty cycle Emissions to EN 50081-2 At 25° ° C: ±(0.1 % of full scale +½ LSD) RF interference EN 55011 Enclosure class A Over 0 to 50° °C range: ±(0.2% of full scale +½ LSD) Power mains class A Reading Rate: 10/sec. Setpoint Filtering: Programmable Digital 1. No loss of performance during EMI disturbance at 10 V/m. Setpoint Ramping: Programmable, 0.1 to 999.9 degrees/minute. Unit is panel mounted in a metal enclosure (Buckeye SM7013-0 or 16. HEATER CURRENT MONITOR INPUT: (optional) equivalent) that provides at least 20 dB shielding effectiveness. Metal Type: Single phase, full wave monitoring of load currents controlled by main panel is connected to earth ground. output (01). Power Line and I/O cables routed in metal conduit connected to earth Input: 100 mA AC output from current transformer (RLC #CT004001) or ground. any CT with 100 mA AC output. 2. Self-recoverable loss of performance during EMI disturbance at 10 Vrms: Display Scale Range: 1.0 to 999.9 Amps or 0.0 to 100.0% Analog output may deviate during EMI disturbance. Input Resistance: 5 Ω For operation without loss of performance: Accuracy: Install power line filter, RLC#LFIL0000 or equivalent. At 25° ° C: ±(0.5 % of full scale +½ LSD), (5 to 100% of Range) OR Over 0 to 50° °C range: ±(1.0% of full scale +½ LSD), (5 to 100% of Range) Install 2 ferrite cores, RLC#FCOR0000 or equivalent, to AC lines at Frequency: 50 to 400 Hz. unit for frequencies above 5 MHz. Alarm Mode: Dual acting; heater element fail detect and control device fail I/O cables routed in metal conduit connected to earth ground. detect. Refer to the EMC Installation Guidelines section of the manual for additional Overrange: 105% Capacity information. Overload: 200 mA (continuous). 21. CONNECTION: Wire clamping screw terminals 17. SERIAL COMMUNICATIONS: (optional) 22. CONSTRUCTION: Black plastic alloy case and collar style panel latch. Panel Type: RS485 multipoint, balanced interface latch can be installed for vertical or horizontal instrument stacking. One piece Baud Rate: 300 to 9600 tinted plastic bezel. Bezel assembly with circuit boards can be removed from the Data Format: 7O1, 7E1, 7N2, 8N1 case to change the output board without removing the case from the panel or Node Address: 0-99, max of 32 units per line disconnecting wiring. Unit meets NEMA 4X/IP65 requirements for indoor use, Transmit Delay: 2-100 msec or 100-200 msec when properly installed. Installation Category II, Pollution Degree 2. Data Encoding: ASCII 23. WEIGHT: 0.38 lbs (0.17 kgs) Isolation w.r.t Main Input Common: 500 Vrms for 1 min. (50 V working) Not isolated w.r.t. Remote Setpoint or Heater Current inputs, or Analog Output common Note: RS485 and the Analog Output commons are not internally isolated within the controller. The terminating equipment of these outputs must not share the same common (ie. earth ground). 18. ENVIRONMENTAL CONDITIONS: 3 A Second Linear DC output is dedicated for retransmission of input BASIC OPERATION temperature. The output can be scaled and converted independent of the input The T48 controls a process temperature by measuring the temperature via an and Main Linear DC output. This output is isolated from the input. input probe, then calculating a control output power value by use of a modified PID control algorithm. The unit controls the system with the new output power value to keep the process temperature at setpoint. The PID control algorithm SETPOINT FEATURES incorporates features which provide for high control accuracy and low The controller setpoint can be protected from out of range values by temperature overshoot from process disturbances. programming the setpoint range limit values. Additionally, safeguards from inadvertent data entry can be programmed. A second setpoint value can be programmed which can be made active by a FRONT PANEL FEATURES user input and/or through the front panel on selected models. In the normal operating mode, the unit displays the process temperature The setpoint ramp feature ramps the setpoint value at start-up or any time a in the upper display. One of the following parameters can be viewed in the setpoint change is made, at a user programmable rate. This feature reduces lower display: thermal shock to the process and helps to minimize temperature overshoot. - Setpoint - % Power Output - Temperature Deviation INPUT FEATURES - Heater Current A programmable input filter can be used to stabilize readings from a process - Temperature symbol (F or C) with varying or oscillating temperature characteristics, helping to provide better - Blank Display temperature control. A programmable temperature shift function can be used to compensate for probe errors or to have multiple T48 units indicate the same The user scrolls through these parameters by pressing the D button. If nominal temperature. enabled, the control setpoint or power output (manual mode only) can be The programmable User Input can be used to control a variety of functions, directly modified in this mode. such as auto/manual transfer of the controller, reset alarm output(s), transfer to In the normal operating mode, parameters are selected by use of the P button second setpoint, etc. and modified by use of the UP and DOWN buttons. Parameters are then entered by the P button, which advances the user to the next parameter. Pressing the D button immediately returns the controller to the normal operating mode without OUTPUT FEATURES changing the currently selected parameter. Programmable output power limits provide protection for processes where excessive power can cause damage. Automatic sensor probe break detection, for fail-safe operation, causes the controller to default to a programmed output HARDWARE FEATURES power (upscale or downscale burnout). Programmable output cycle time, A fast 100 msec input sampling rate provides quick controller response to a output hysteresis and dampening can reduce output activity without degrading process disturbance, thus providing excellent temperature control. Measurement control accuracy. The main outputs can operate in PID, ON/OFF, or manual accuracy of 0.3% of span ±1°C or better, provides close process control control modes. conforming to the desired control setpoint value. The T48 accepts a variety of both thermocouple and RTD temperature probes. An output board contains the Main Control output, Alarm 1 output, Alarm 2/Cooling output, and/or Linear CONTROL AND ALARM OUTPUTS DC output. Since the controller is serviceable from the front of the panel, the In addition to the Linear DC outputs, there are up to three types of ON/OFF output board (on some models) may be easily changed or replaced without outputs.These outputs can be relay, logic, or triac for control or alarm purposes. disturbing the wiring behind the panel. No re-programming is required when Relay outputs can switch user applied AC or DC voltages. Logic/SSR drive changing or replacing the output board for units without the Linear DC output outputs supply power to external SSR power units. One Logic/SSR Drive output option. Units with the linear output option require calibration procedure for the can control up to four SSR power units at one time. The Triac output supplies new linear output. one Amp of AC current for control of an external AC relay or triac device. Low-drift, highly stable circuitry ensures years of reliable and accurate temperature control. The recommended two year re-calibration interval is easily AUTO-TUNE accomplished via the programming menu. The T48 has an auto-tune feature which, on demand, automatically determines the PID control parameters for a particular thermal process. After REMOTE SETPOINT INPUT completion of auto-tune, the PID parameters are automatically optimized for The remote setpoint input facilitates the use of a remote signal to drive the that process and loaded into non-volatile memory. The operator may view and controller’s setpoint. The remote signal can be scaled independent to that of the modify the parameters as desired. controller’s range. The controller’s response to local/remote setpoint transfers Auto-tune may be invoked either at start-up or at setpoint, depending on the can be programmed. Also, the remote signal is filtered by use of an adaptive process requirements. An auto-tune programmable dampening factor produces filter. With this filter, relatively large filtering time constants can be used various levels of process control and response characteristics. without suffering from long settling times. The time constant and filter disable band are programmable. Additionally, the remote signal can also be velocity RS485 Communications limited (or ramped) to slow the controller’s response to changes in setpoint. This The RS485 communications option allows the connection of up to 32 devices results in a steady control response with no overshoot. on a single pair of wires with a distance of up to 4,000 feet and a maximum baud rate of 9600. Since the same pair of wires are used for both transmit and receive, only one way communication is possible at any given time. The controller has HEATER CURRENT MONITOR The T48 provides a direct readout of process heater current. This provides a programmable response time to allow the host device adequate time to release the communication line for a transmission. valuable information regarding single phase heater system integrity. It is especially useful on extruder and large oven applications where adjacent Selected parameters from the T48 can be interrogated or changed, and alarm output(s) may be reset by sending the proper command code via serial controllers mask the effect of a failed heater. The heater break alarm senses two types of heater system faults: communications. It is also possible to invoke Auto-tune through the serial port. Serial communications used with SFCRM software allows for easy controller 1) Main control output is “on” and heater current is below alarm value. This indicates failed heater or failed parts of heater, breaker trip, failed power parameter configuration by computer. control device, etc. 2) Main control output is “off” and heater current is above 10% of alarm value. HEATING AND COOLING SYSTEMS This indicates a failed power control device, wiring fault, etc. The T48 is available with dual outputs to provide heating and cooling to those processes that require them. For example, many extruder applications require both heating and cooling to maintain accurate extruder barrel and die LINEAR DC ANALOG OUTPUTS temperatures. The T48 is easily configured for these types of applications. The Main Linear DC output has independent scaling, programmable output update time and filter (damping) time. These parameters permit flexibility in process configuration. The output can be set for 0 to 10 V, 0 to 20 mA or 4 to 20 mA ranges, and can be configured for control or for transmission of temperature or setpoint values. 4 Configuration 2, Outputs (2-OP) CONTROLLER PROGRAMMING * “CYCt” - Enter time proportioning cycle time Front Panel Program Disable allows all of the controller’s set-ups to be “OPAC” - Select output control action locked-out from further operator intervention after the initial set-up. “OPLO” - Enter output power low limit The following four programming modes allow the controller to adapt to any “OPHI” - Enter output power high limit required user-interface level: “OPFL” - Enter probe fail power preset “OPdP” - Enter output control dampening Unprotected Parameter Mode “CHYS” - Enter ON/OFF control hysteresis Protected Parameter Mode “tcOd” - Select auto-tuning dampening Hidden Function Mode “ANtP” - Main Linear DC analog output range Configuration Parameter Mode “ANAS” - Main Linear DC analog output source “ANut” - Main Linear DC analog output update time UNPROTECTED PARAMETERS MODE * “ANLO” - Main Linear DC analog output scaling low The Unprotected Parameters Mode is accessible from the Normal Display “ANHI” - Main Linear DC analog output scaling high Mode when program disable is inactive or when the proper access code number Configuration 3, Parameter Lock-Outs (3-LC) * from the Protected Parameter Mode is entered. The Configuration Parameter “SP” - Select setpoint access level Modes can be accessed only from this mode. “OP” - Select power access level “dEv” - Enable deviation display “SP” - Enter setpoint “Hcur” - Enable heater current display “OP” - Enter output power “UdSP” - Enable temperature scale display “ProP” - Enter proportional band “CodE” - Enter parameter access code “Intt” - Enter integral time “PId” - Select PID access level “dErt” - Enter derivative time “AL” - Select alarm access level “AL-1” - Enter value for alarm #1 “ALrS” - Enable alarm reset access “AL-2” - Enter value for alarm #2 “SPSL” - Enable local/remote selection “CNFP” - Select configuration access point “trnF” - Enable auto/manual mode selection “End” - Return to normal display mode “tUNE” - Enable auto-tune invocation PROTECTED PARAMETERS MODE * Configuration 4, Alarms (4-AL) * The Protected Parameters Mode is enabled when program disable is active. “ACt1” - Select operation mode of alarm #1, or select heat output This mode prevents access to the Configuration Parameter Modes without the “rSt1” - Select reset mode of alarm #1 “Stb1” - Enable activation delay of alarm #1 proper access code number. Only the parameters that are enabled in the “AL-1” - Enter value for alarm #1 Configuration 3 parameter (lock-out section) can be accessed. “ACt2” - Select operation mode of alarm #2, or select cooling output “rSt2” - Select reset mode of alarm #2 “ProP” - Enter proportional band “Stb2” - Enable activation delay of alarm #2 “Intt” - Enter integral time “AL-2” - Enter value for alarm #2 “dErt” - Enter derivative time “AHYS” - Enter hysteresis value for both alarms “AL-1” - Enter value for alarm #1 “AL-2” - Enter value for alarm #2 Configuration 5, Cooling (5-O2) * “CodE” - Enter value to access unprotected parameters and “CYC2” - Enter cooling time proportioning cycle time configuration parameters “GAN2” - Enter cooling relative gain “db-2” - Enter heat/cool deadband or overlap HIDDEN FUNCTION MODE * The Hidden Function Mode is accessible from the Normal Display Mode. Configuration 6, Serial Communications (6-SC) * “bAUd” - Select baud rate The functions in this mode may be locked-out individually in Configuration 3 “ConF” - Select character frame format parameter (lock-out section). “Addr” - Enter address “Abrv” - Select abbreviated or full transmission “SPSL” - Select local (SP1 or SP2) or remote setpoint “PoPt” - Select print options “trnF” - Transfer between automatic (PID) control and manual control “tUNE” - Invoke/cancel PID Auto-tune Configuration 7, Remote Setpoint Input (7-N2) * “ALrS” - Reset latched alarms “dSP1” - Enter remote setpoint display scaling value #1 “INP1” - Enter remote setpoint process scaling value #1 CONFIGURATION PARAMETER MODE “dSP2” - Enter remote setpoint display scaling value #2 The Configuration Parameter Mode allows the operator to set-up the basic “INP2” - Enter remote setpoint process scaling value #2 requirements of the controller. It is divided into sections which group together “FLtr” - Enter remote setpoint filter time constant related programming steps, such as inputs, outputs, alarms, etc. Upon “bAnd” - Enter remote setpoint filter disable band “trnF” - Select Local/Remote setpoint transfer response completion of each section, the program returns to the Configuration Access Point, allowing the user to return to the Normal Display Mode. Configuration 7 - Heater Current Parameters (7-N2) * “Hcur” - Enter full scale rating of CT Configuration 1, Inputs (1-IN) “tYPE” - Select input probe type Configuration 8, Second Linear DC Analog Output (8-A2) * “SCAL” - Select temperature scale “A2tP” - Second linear DC analog range “dCPt” - Select temperature resolution “A2LO” - Second linear DC analog scaling low “FLtr” - Select level of input filtering “A2HI” - Second linear DC analog scaling high “SHFt” - Enter input correction shift (offset) “SPLO” - Enter setpoint lower limit Configuration 9, Factory Service Operations (9-FS) “SPHI” - Enter setpoint higher limit “Code 48” - Calibrate Instrument “SPrP” - Enter setpoint ramp rate “Code 66” - Reset parameters to factory setting “InPt” - Select user input function These parameters may not appear due to option configuration or other * programming. 5 MULTIPLE UNIT STACKING ACCESSORY - EXTERNAL SSR POWER UNIT The T48 is designed for close spacing of multiple units. Units can be The external SSR Power Unit is used with T48s equipped with Logic/SSR stacked either horizontally or vertically. For vertical stacking, install the panel Drive outputs to switch loads up to 240 VAC @ 45 Amps, 25°C ambient. The latch with the screws to the sides of the unit. For horizontal stacking, the panel unit is operated by applying a low level DC control signal to the isolated latch screws should be at the top and bottom of the unit. The minimum spacing input. The unit features zero cross detection circuits which reduces radiated from center line to center line of units is 1.96" (49.8 mm). This spacing is the RFI when switching load currents. With no contacts to wear out, the SSR same for vertical or horizontal stacking. Power Unit provides virtually limitless operational life. The unit is supplied with an integral heat sink for immediate installation. Note: When stacking units, provide adequate panel ventilation to ensure that the maximum operating temperature range is not exceeded. PANEL LATCH INSTALLED FOR PANEL LATCH INSTALLED FOR VERTICAL UNIT STACKING HORIZONTAL UNIT STACKING PANEL CUT-OUT SPACING FOR MULTIPLE UNIT STACKING. HORIZONTAL ARRANGEMENT SHOWN. External SSR Power Unit: Part Number: RLY50000 Switched Voltage Range: 50 to 280 VAC Load Current: 45 Amps max. @ 25°C ambient temperature 35 Amps max. @ 50°C ambient temperature On State Input: 3 to 32 VDC @ 1500 Ω impedance. (isolated) (Use Logic/SSR drive output.) Off State Input: 0.0 to 1.0 VDC Size: 5.5" (14 cm) L x 4.75" (12 cm) W x 2.62" (6.6 cm) H ACCESSORY - CURRENT TRANSFORMER-50 A The external Current Transformer is used when specifying the T48s equipped with the Heater Current Monitor. ACCESSORY - CURRENT TRANSFORMER-40 A The external Current Transformer is used when specifying the T48s equipped with the Heater Current Monitor. Current Transformers: Part Number: CT004001 Current Ratio: 40 : 0.1 (Amperes) Part Number: CT005001 Current Ratio: 50 : 0.1 (Amperes) Max Heater Current: 50 A Dielectric Strength: 1000 VAC (For 1 minute) Operation Frequency: 50 to 400 Hz Insulation Class: 0.6 KV BIL, 10 KV full wave. Vibration Resistance: 50 Hz (Approx 10 G) Terminals: Solder Type Terminals: Brass studs No. 8-32 UNC with flat washer and hex nuts. Window Diameter: 1.13" (28.7 mm) Window Diameter: 0.228" (5.8 mm) Weight: 0.406 oz (11.5 g) Weight: 8 oz (226.0 g) 6 APPLICATION (Terminal assignments are model number dependent.) PLASTICS EXTRUDER APPLICATION Several T48 controllers are employed to control the temperature of a plastics extruder. Each T48 controls a heating element and a cooling water solenoid to maintain each extruder zone at the desired temperature. The Heater Current Monitor option is used to provide a readout of the heater current. The multi-function User Input can be programmed to allow selection of manual operation when connected to common. This allows the user to hold the control output of the controller during abnormal process conditions. OEM PAINT SPRAYER APPLICATION An OEM manufacturing spray painting equipment utilizes the T48 to maintain optimum paint temperature. In addition to the low cost, the 1/16 DIN package size permits the OEM to design temperature control into various sized painting equipment, from small hand sprayers to large paint booths. The heating element used to heat the paint, is connected to the Main Control Output (OP1) programmed for On/Off control. Alarm 1 is programmed as Band Inside Acting, so that as long as the paint temperature is within manufacturer’s specifications for temperature, the “GO” light is on. Alarm 2 is programmed as Band Outside acting so that the “NO GO” light is lit when the paint temperature is more than 12° outside the manufacturer’s specifications of 140 to 150°F. (Terminal assignments are model number dependent.) MULTIPLE UNIT/REMOTE SETPOINT APPLICATION Eight T48 controllers are used in a drying oven. Each T48 controls a zone Whenever the master controller’s setpoint is changed, the slave controller’s within the oven. Depending upon the material to be dried, and its initial setpoint changes automatically. moisture content, the drying setpoint temperature varies. A master T48 The remote setpoint input at each slave controller can be scaled controller transmits setpoint via linear DC output. This signal is received as independently. a remote setpoint signal by the other slave controllers. (Terminal assignments are model number dependent.) 7 ORDERING INFORMATION Options and Output Boards are factory configured per the part number specified. Part numbers without replacement output boards listed must be returned to the factory for output board replacement. MODELS WITHOUT RS485 AND LINEAR DC ANALOG OUTPUT DEDICATED DEDICATED (ALARM 2) REMOTE HEATER REPLACEMENT PART NUMBERS MAIN CONTROL ALARM 1 A2 OR 02 SETPOINT CURRENT OUTPUT 18-36 VDC/24 VAC 85 TO 250 VAC A1 OUTPUT (COOL)* INPUT @ INPUT @ BOARD 01 OUTPUT Relay RBD48100 T4810010 T4810000 Relay Relay RBD48111 NA T4811000 Relay Relay Relay RBD48111 T4811110 T4811100 Relay Relay Relay YES RBD48111 T4811113 T4811103 Relay Relay Relay YES RBD48111 T4811114 T4811104 Logic/SSR RBD48200 T4820010 T4820000 Logic/SSR Relay RBD48211 NA T4821000 Logic/SSR Relay Relay RBD48211 T4821110 T4821100 Logic/SSR Relay Relay YES RBD48211 T4821113 T4821103 Logic/SSR Relay Relay YES RBD48211 T4821114 T4821104 Triac Logic/SSR Logic/SSR NA T4832210 T4832200 * - These part numbers have a single output, programmable as either Control (PID) or as an Alarm. @ - These part numbers are equipped with a second setpoint. Option Boards are installed at the factory for the appropriate models. These boards are only needed for field replacement. MODELS WITH RS485 OR LINEAR DC ANALOG OUTPUT DEDICATED MAIN CONTROL DEDICATED (ALARM 2) REMOTE HEATER MAIN SECOND PART NUMBERS RS485 MAIN CONTROL O1 OR A1 ALARM 1 A2 OR O2 SETPOINT CURRENT ANALOG ANALOG @ O1 OUTPUT (ALARM 1) * A1 OUTPUT (COOL) * INPUT @ INPUT @ OUTPUT** @ OUTPUT** @ 18-36 VDC/24 VAC 85 TO 250 VAC 1 Relay NA T4810002 YES Relay Relay YES YES T481011A T481010A Relay Relay YES T4810111 T4810101 Relay Relay YES YES T4810115 T4810105 Relay Relay YES YES T4810116 T4810106 Relay Relay YES YES T4810117 T4810107 Relay Relay YES YES T4810118 T4810108 Relay Relay YES YES T4810119 T4810109 2 Relay Relay Relay T4811112 T4811102 YES Logic/SSR Logic/SSR YES T4820211 T4820201 Logic/SSR Logic/SSR YES YES T4820215 T4820205 Logic/SSR Logic/SSR YES YES T4820216 T4820206 Logic/SSR Logic/SSR YES YES T4820218 T4820208 Logic/SSR Logic/SSR YES YES T4820219 T4820209 Logic/SSR Relay Relay YES T4821112 T4821102 * - These part numbers have a single output, programmable as either Control (PID) or as an Alarm. ** - These part numbers are jumper and program selectable for either a current or voltage Linear DC output. @ - These part numbers are equipped with a second setpoint. 1 - Replacement Output Board RBD48100 may be used. 2 - Replacement Output Board RBD48111 may be used. ACCESSORIES MODEL NO. DESCRIPTION PART NUMBERS External SSR Power Unit (for Logic/SSR output models) RLY50000 Single Phase 25 A DIN Rail Mount SSR RLY60000 RLY Single Phase 40 A DIN Rail Mount SSR RLY6A000 Three Phase DIN Rail Mount SSR RLY70000 40 Ampere Current Transformer (for Heater Current Input models) CT004001 CT 50 Ampere Current Transformer (for Heater Current Input models) CT005001 SFCRM Crimson 2 PC Configuration Software for Windows 98, ME, 2000 and XP (for RS485 models) SFCRM ICM4 RS232/RS485 Serial Converter Module ICM40030 ICM5 Three way isolated RS232/RS485 Serial Converter ICM50000 * Crimson software is available for download from http://www.redlion.net Red Lion Controls AP Red Lion Controls Red Lion Controls BV 31, Kaki Bukit Road 3, 20 Willow Springs Circle Basicweg 11b #06-04/05 TechLink York PA 17402 NL - 3821 BR Amersfoort Singapore 417818 Tel +1 (717) 767-6511 Tel +31 (0) 334 723 225 Tel +65 6744-6613 Fax +1 (717) 764-0839 Fax +31 (0) 334 893 793 Fax +65 6743-3360

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the T4811102 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

APOLLO CURRENT LOOP W/O EXCITATION, 115

METER APOLLO CURRENT LOOP W/EXCITATION

APOLLO CURRENT LOOP , W/O EXCITATION, 2

APOLLO CURRENT LOOP , W/EXCITATION, 230

VOLTMETER PRCOESS CONTROL W/O EXCITATIO

METER APOLLO PROCESS VOLT W/EXCITATION