Elite.Parts chervon right Manufacturers chervon right R chervon right RED LION CONTROLS chervon right CX-150
About product Specifications Features Datasheet FAQ

RED LION CONTROLS CX-150

Image of RED LION CONTROLS CX-150

Description

Red Lion Controls CX-150 Operator Interface Terminal - 2 Line x 40 Character Display, 500 Alarm Point Logger, Password Protection, RTC, 32 Bit / Floating Point Math, NEMA 4/IP65 Steel Enclosure

Part Number

CX-150

Price

Request Quote

Manufacturer

RED LION CONTROLS

Lead Time

Request Quote

Category

TBD

Specifications

Altitude

Up to 2000 meters

CONSTRUCTION

Metal enclosure with NEMA 4/IP65 front plate when correctly fitted with the gasket provided. This unit is rated for NEMA 4/IP65 indoor use. Installation Category I, Pollution Degree 2

DISPLAY

2 lines of 40 characters, 5 mm high Vacuum Fluorescent display

ENVIRONMENTAL CONDITIONS

Operating Temperature: 0 to 40°C. Storage Temperature: -20 to 80°C

FIELD CONNECTIONS

Removable screw terminal blocks.

KEYPAD

5 screen legendable soft keys, raise, lower, next, previous, exit, menu, alarms and mute keys, all with Tactile feedback.

MEMORY

128 K (64 K user) battery backed RAM (Battery life expectancy 10 years). Optional factory fit expansion to 256 K (192 K user).

Operating and Storage Humidity

80% max. relative humidity (non-condensing) from 0°C to 40°C.

PHYSICAL DIMENSIONS

L: 285 mm, H: 106 mm, D: 57 mm.

POWER REQUIREMENTS

11 min. to 30 max. VDC @ 4.7 W

Power Up Current

2.5 A for 25 msec. max. Must use a Class 2 or SELV rated power supply.

SERIAL PORTS

One RS-232 for PC or printer connection, one RS232 and one RS485 for PLC connection up to 19200 Baud. (Can be used as a three port device for multiple protocol applications)

WEIGHT

2.1 lbs. (0.95 Kg)

Features

Datasheet

pdf file

CX150000-datasheet-12500312161.pdf

59 KiB

Extracted Text

BULLETIN NO. CX150-A DRAWING NO. LP0422 REVISED 11/98 RED LION CONTROLS INTERNATIONAL HEADQUARTERS EUROPEAN HEADQUARTERS 20 Willow Springs Circle, York, Pa. 17402, (717) 767-6511 FAX: (717) 764-0839 892 Plymouth Road, Slough, Berkshire SL1 4LP Web site- http://www.redlion-controls.com E-mail- sales@redlion-controls.com ENGLAND +44 1753 696888 FAX: +44 1753 696339 Operator Interface Terminals MODEL CX-150 2 X 40 VFD OPERATOR TERMINAL l 2 LINE X 40 CHARACTER VACUUM FLUORESCENT DISPLAY l 500 ALARM POINT LOGGER l RECIPE HANDLING l COMPREHENSIVE REPORT GENERATION l UNLIMITED PASSWORD PROTECTION l REAL TIME CLOCK, BATTERY BACKED l EXPRESSION EVALUATION l 32 BIT / FLOATING POINT MATH l DIRECT, NETWORK (Including Multiple protocols) OR MODEM LINK TO PLC l NEMA 4/IP65 STEEL ENCLOSURE l CE COMPLIANT 6. PHYSICAL DIMENSIONS: L = 285 mm, H = 106 mm, D = 57 mm. DESCRIPTION 7. CONSTRUCTION: Metal enclosure with NEMA 4/IP65 front plate when The CX-150 from the Paradigm Range of operator interfaces meets the ever correctly fitted with the gasket provided. This unit is rated for NEMA 4/IP65 increasing demands of industry for powerful easy-to-use terminals. Both indoor use. Installation Category I, Pollution Degree 2 hardware and software are designed to allow the user to easily upgrade and take 8. FIELD CONNECTIONS: Removable screw terminal blocks. full advantage of our continuing development and improvements to our 9. ENVIRONMENTAL CONDITIONS: products. Operating Temperature: 0 to 40°C Storage Temperature: -20 to 80°C SPECIFICATIONS Operating and Storage Humidity: 80% max. relative humidity 1. POWER REQUIREMENTS: 11 min. to 30 max. VDC @ 4.7 W (non-condensing) from 0°C to 40°C. Power Up Current: 2.5 A for 25 msec. max. Altitude: Up to 2000 meters Must use a Class 2 or SELV rated power supply. 10. WEIGHT: 2.1 lbs. (0.95 Kg) 2. DISPLAY: 2 lines of 40 characters, 5 mm high Vacuum Fluorescent display 3. KEYPAD: 5 screen legendable soft keys, raise, lower, next, previous, exit, menu, alarms and mute keys, all with Tactile feedback. ORDERING INFORMATION 4. MEMORY: 128 K (64 K user) battery backed RAM (Battery life expectancy MODEL NO. DESCRIPTION PART NUMBER 10 years). Optional factory fit expansion to 256 K (192 K user). VFD, 4 X 20, 8 Function keys, 128 K memory CX150000 5. SERIAL PORTS: One RS-232 for PC or printer connection, one RS232 and CX-150 VFD, 4 X 20, 8 Function keys, 256 K memory CX150010 one RS485 for PLC connection up to 19200 Baud. (Can be used as a three port device for multiple protocol applications) DIMENSIONS “In inches (mm)” PANEL CUT-OUT 1 ORDERING INFORMATION SAFETY SUMMARY All safety related regulations, local codes and instructions that appear in the MODEL NO. DESCRIPTION PART NUMBER manual or on equipment must be observed to ensure personal safety and to CL-05 LCD, 2 X 20, 3 Soft keys, 128 K memory CL050000 prevent damage to either the instrument or equipment connected to it. If LCD, 2 X 20, 8 Function, 3 Soft keys, 128 K memory CL100000 CL-10 equipment is used in a manner not specified by the manufacturer, the protection LCD, 2 X 20, 8 Function, 3 Soft keys, 256 K memory CL100010 LCD, 2 X 40, 5 Soft keys, 128 K memory CL150000 provided by the equipment may be impaired. CL-15 LCD, 2 X 40, 5 Soft keys, 256 K memory CL150010 Do not use this unit to directly command motors, valves, or other actuators LCD, 4 X 20, 8 Function, 3 Soft keys, 128 K memory CL200000 CL-20 not equipped with safeguards. To do so, can be potentially harmful to persons LCD, 4 X 20, 8 Function, 3 Soft keys, 256 K memory CL200010 or equipment in the event of a fault to the unit. VFD, 2 X 20, 8 Function keys, 128 K memory CX100000 CX-100 VFD, 2 X 20, 8 Function keys, 256 K memory CX100010 VFD, 2 X 40, 5 Soft keys, 128 K memory CX150000 CX-150 VFD, 2 X 40, 5 Soft keys, 256 K memory CX150010 VFD, 4 X 20, 8 Function keys, 128 K memory CX200000 CX-200 VFD, 4 X 20, 8 Function keys, 256 K memory CX200010 CAUTION: Read complete instructions prior to EDICT-97 Development Kit installation and operation of the unit. Includes Software, Manual and 9-pin RS232 SFEDT Programming cables Communication Cables P895xxxZ TROUBLESHOOTING For further technical assistance, contact technical support at the appropriate company numbers listed. COMMON FEATURES FOR CHARACTER BASED OPERATOR TERMINALS PROGRAMMABILITY ALARMS The Paradigm unit can monitor and log from 100 to 500 alarms, depending Event Driven Configuration Tool on model. Such triggers as a simple bit level transition, a PLC coil activation, Edict 97, an extremely powerful Windows 95/3.11 based software program, or a complex application algorithm can activate an alarm. The alarms can be provides for the intuitive configuration of every aspect of the operator time and date stamped, with an automatic screen display and/or downloading to interface’s behavior. The requirement for time consuming PLC ladder logic is a printer for hard copy recording purposes. drastically reduced by the unique event driven approach of EDICT 97. The capability of this program, in conjunction with the PLC and the Paradigm operator interface unit, ensures a great deal of advanced functionality for your REAL TIME SCHEDULE system. This powerful PLC/Paradigm system provides many of the capabilities Real time schedule allows for repetitive or one time task to take place in the and features normally associated with the more complicated and costly system. Typically a schedule action similar to...At 1:55 PM on Monday, PC/SCADA systems. Display pages are easily generated, including PLC and Wednesday, and Friday, print the production report...is required in the internal variables, text strings, or bar charts. All dynamic elements are also application. In conjunction with the recipe capabilities, a downloading of a available as alarms, recipes, triggers, and reports, for the run time software. special recipe can be requested by the real time schedule feature. After completion of the programming, the program is directly downloaded to the operator interface from your PC, without any compiling or saving USER PROGRAMS requirement. When you require a change in your program, EDICT 97 loads only This feature offers the user the ability to incorporate custom application the change, not the entire program, saving valuable on-line time. requirements via a powerful program language. For example, a program designated “Calculate Volume” which determines the amount of fluid in a round DYNAMIC DISPLAY PAGE ELEMENTS tank at specific temperatures could be created. This program would be triggered Each display page has provisions to show static and dynamic information, to run and display each time the page denoted as “Volume Now” is requested. including data variables, text messages, time, and date. The ability to customize to your application’s specialized needs is easily Data Variables can be either PLC derived or internally generated, either in data solved with the user program capability. entry or display only mode. The Paradigm unit has an extremely powerful math capability, allowing the operator to manipulate the variables to meet the KEYBOARD EDITING specific application’s demands. If required, the display can be formatted to All the interface keys can be programmed to perform virtually unlimited BCD, binary, hex, floating point, and string. Upper and lower limits of data functions with each key, having multiple actions assigned to three types of key entry variables are fully supported and able to be password protected. events: key pressed, key held down (auto repeat), and key released. Typical key Text Message Animation enables several different types of animated text from actions would be Go to page, set value, load recipe, view alarms, print report, a local or global message table to be displayed. The message displayed is and many more. dependent on the condition of the particular controlling expression. The controlling expression may be a PLC bit level, a timer value, preset counter COMMUNICATIONS condition, or any one of a wide variety of message triggers. With over 70 communication drivers available, the Paradigm operator Time and Date in the Paradigm unit has the capability to display in any interface offers a wide range of connectivity including: PLCs, Variable Speed combination of year, month, day, hours, minutes, and seconds. Drives, Temperature Controllers, Bar Code Readers, etc. Utilizing real PLC data references, the automatic comms configuration optimizes the system’s Bar Graphs in horizontal format are easily attached to data variables. The communication performance. In the event that your specific driver does not partial or full length bar graph displays can be scaled and offset to optimize appear on the Paradigm drivers list, let us know, as this list is always being the required display effect. expanded to meet our customers’ needs. SECURITY The password protection scheme provides the ultimate in tamper-proof capability. Access can be limited on a unit, page, recipe, or even individual data entries. 2 Please note that the old battery must be disposed of in a manner which HARDWARE INFORMATION complies with your local waste regulations. Also, the battery must not be This bulletin contains a variety of information related to the installation and disposed of in fire or in a manner whereby it may be damaged and its contents operation of the Operator Interface supplied. Ideally, you should read this come into contact with human skin. document thoroughly before attempting to use the equipment. For information about the software aspects of the terminal, please consult other documentation. INSTALLATION & CONNECTIONS The unit meets NEMA 4/IP65 requirements for indoor use, when properly CONTENTS OF PACKAGE installed. The units are intended to be mounted into an enclosed panel. The Operator Interface is supplied in a packaging box containing the following... Installation Environment u The interface terminal itself. The unit should be installed in a location that does not exceed the maximum u A NEMA 4/IP65 rated mounting gasket. operating temperature and provides good air circulation. Placing the unit near u A bag containing panel hardware. devices that generate excessive heat should be avoided. u This hardware bulletin. Continuous exposure to direct sunlight may accelerate the aging process of u If any of these items is missing, please contact your supplier the bezel. The bezel should be cleaned only with a soft cloth and neutral soap immediately. product. Do NOT use solvents. Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the POWER SUPPLY REQUIREMENTS keypad of the unit. The Operator Interface requires a 24 V power supply rated at 0.5 A unless otherwise stated on the label. CONNECTING TO A PLC u The Operator Interface requires a power supply capable of supplying a The Operator Interface is designed to operate with a PLC. A serial current of 500 mA at a regulated voltage of 24 V. Supplies providing communication connection must be made between the operator interface between 18 V and 30 V are also suitable. terminal and PLC, and the details of this connection vary according to which u The terminal may take as little as 100 mA in certain circumstances, so PLC is used. be sure that the chosen power supply can operate correctly with this The following section lists the connection details for the PLC to be used . load. Large switch-mode supplies tend to need a certain minimum load before they will operate correctly. PLC TYPE In any case, it is very important that the power supply is mounted correctly if Details on how to connect to most PLCs are available on request from RLC. the unit is to operate reliably. A very high proportion of reported problems are caused by incorrect power supply installation, so please take care to observe the CONNECTING TO AN IBM PC/AT following points... The Operator Interface is programmed via software running on an IBM u The power supply must be mounted close to the unit, with usually not PC/AT or a compatible computer. The connection between the PC/AT and the more than 6 feet of cable between the supply and the Operator Interface. operator interface terminal is made via a custom cable provided with the EDICT Ideally, as short a length as is possible should be used. In particular, the Developer’s Kit. The cable is designed for a 9-way serial port. Please contact power supply should not be mounted on the back of the panel when the your supplier if you require a 25-way version. Operator Interface is installed in the panel door unless a short cable run can be achieved. PROGRAMMING PORT PIN OUT u The wire used to connect the Operator Interface’s power supply should The Operator Interface’s programming port is sometimes used to connect be of at least 22 gauge wire. If a longer cable run is used, you should other RS-232 devices, such as printers. The following illustration and table use even thicker cable. The routing of the cable should be kept away gives the pin-out of this port to enable such connections to be made. from large contactors, inverters and other devices which may generate significant electrical noise. BATTERY BACKUP ISSUES The Operator Interface is supplied with a Lithium Battery designed to maintain the internal memory and real-time clock during power outages. Assuming the operator interface terminal is powered up for 50% of the time, this battery should last over 4 years. A “Battery Low” system variable is available so that the programmer can choose specific action(s) to occur when the battery voltage drops below its nominal voltage. It is possible to replace the battery without losing the contents of the Operator Interface’s memory, but this does not reduce the importance of ensuring that a copy of the terminal’s configuration is kept readily at hand to allow the terminal The above table denotes the pin names of the programming port. When to be re-loaded in the case of mishaps. Please remember that it is not possible to connecting, the pin name at the programming port is connected to the opposite extract the contents of a terminal for subsequent re-loading, so the importance of that pin name at the destination device. of keeping a copy on disk cannot be over stressed. CHANGING THE BATTERY MOUNTING INSTRUCTIONS To change the internal battery, follow these steps... The Operator Interfaces are designed for through-panel mounting. A u Remove the power and PLC communications connector from the unit. neoprene gasket is provided, to enable sealing to NEMA 4/IP65 specification. u Remove the four screws from the rear-cover. The panel cut-out diagram for the model supplied is provided. All mounting u Remove the cover, ensuring that the right-hand edge is raised first to holes should be drilled for 0.14” clearance. Care should be taken to remove any avoid fouling the earth stud. You may have to pivot the cover to an loose material from the mounting hole to avoid such metal falling into the angle of about 30°to achieve this. Operator Interface itself during installation. u If you wish to avoid losing the terminal’s configuration, reconnect the power connector and re-apply power. Note that this will require the FUNCTION KEY STRIPS panel to be powered-up and, as such, only suitably qualified staff should The function keys on the Models CL-10, CL-20, CX-100, and CX-200, have carry out this procedure. clear windows that permit the user to insert labels appropriate to the process. A u The battery is located in a holder on the main circuit board. This should formatted page is supplied upon which the user can enter function names (e.g. be clearly visible. Remove the battery from its holder. RUN, PRINT, etc.). These strips are inserted from the rear of the panel through u Place the new battery in the holder. The terminal’s power supply can slots below the function keys located underneath the gasket. now be disconnected, if you re-applied power in the step above. Take care that the ink applied will not rub off of the paper, or else blemishes u Replace the lid, screws and connector by following the above procedure will be left on the inside of the window. Laminated paper or plastic film can in reverse. You may like to make a note of the date the battery was prove easier to insert than normal photocopier paper. It also helps if the starting replaced to allow planned maintenance to be carried out. edge of the paper has about 0.25 inches of its corners cut off at a 45 degree u If you did not keep the unit powered-up during battery replacement, hold angle. down the EXIT and MUTE keys on the keyboard and remove and then Note: Add an additional 1.5” to label length to allow for easier insertion and re-apply power. This will clear the internal memory and thus the suitable removal. configuration database should then be re-loaded. 3

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the CX-150 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Red Lion Controls CL200010 4 x 20 LCD Operator Interface Terminal

product

Red Lion Controls IAMA6262 Universal Signal Conditioning Module

product

Red Lion Controls IMP20060 Meter - METER BASE UNIT 115/230

product

Red Lion Controls PRS10011 Speed Switch - Plug-in, 0.1-1HZ, 115VAC

product

Red Lion Controls PSDR-1300 POWER SUPPLY DIN RAIL MOUNT 120VAC/24VDC 1AMP

product

Red Lion Controls VX500TS0 Operator Interface Panels. 640 x 480 | 16 Color | Touchscreen | 736K Mem.