RAYCHEM AMC-F5
Specifications
Accuracy
±3°F (±1.7°C)
Connection
Two 14 AWG (2 mm2) pigtails, one ground screw
Deadband
2°F to 12°F (1.1°C to 6.7°C) above actuation temper
Electrical rating
22 A at 125/250/480 Vac
Enclosure
NEMA 4X, UV-resistant thermoplastics
Entries
One 3/4 in. through hole
Housing exposure limits
–30°F to 140°F (–34°C to 60°C)
Sensor exposure limits
–30°F to 140°F (–34°C to 60°C)
Sensor material
Tin-plated copper
Sensor type
Fluid-filled (silicone) bulb and 2.5 ft (0.8 m) capillary
Set point
40°F (4.4°C) nonadjustable
Set point repeatability
±3°F (±1.7°C)
Switch
SPST
Features
- -30 TO 140 DEG F TEMPERATURE RATING
- 125/250/480 VAC VOLTAGE RATING
- 22 AMPERE CURRENT RATING
- 3.2 INCH W X 2.5 INCH D X 5.2 INCH H SIZE
- SENSOR MATERIAL TIN PLATED COPPER
- SPST SWITCH TYPE
- UL, CSA APPROVAL
Datasheet
AMCF5-d-1115482493s.pdf
118 KiB
Extracted Text
™ DigiTrace ™ DigiTrace R AMC-F5 Fixed set-point freeze-protection thermostat for nonhazardous locations Installation Instructions 3.2 in. 1.1 in. (28 mm) hole (81 mm) for 3/4 in. conduit 0.3 in. 0.2 in. (6 mm) 2.5 in. top of box (8 mm) (2X) (64 mm) 0.3 in. (8 mm) 4.5 in. (114 mm) 3.1 in. 5.2 in. (80 mm) (132 mm) Ø.2" (6 mm) 3.2 in. (81 mm) mounting hole (2X) Description The AMC-F5 thermostat is designed for con- nonadjustable set point of 40°F (4.4°C) and or it can be used to control a contactor coil. trolling freeze protection heat-tracing circuits can be used in an ambient-sensing mode in ordinary areas. The thermostat has a fixed (with capillary coiled) or a line-sensing mode, Specifications Enclosure NEMA 4X, UV-resistant thermoplastics Entries One 3/4 in. through hole Set point 40°F (4.4°C) nonadjustable Sensor exposure limits –30°F to 140°F (–34°C to 60°C) Housing exposure limits –30°F to 140°F (–34°C to 60°C) Switch SPST Electrical rating 22 A at 125/250/480 Vac Accuracy ±3°F (±1.7°C) Deadband 2°F to 12°F (1.1°C to 6.7°C) above actuation temperature Set point repeatability ±3°F (±1.7°C) Sensor type Fluid-filled (silicone) bulb and 2.5 ft (0.8 m) capillary Sensor material Tin-plated copper 2 Connection Two 14 AWG (2 mm ) pigtails, one ground screw Additional Materials Required Wire nuts, AT-180 aluminum tape (for line-sensing applications) Approvals WARNING: This component is an electrical device. It must important warnings and carefully follow all the based on the use of specified parts only. Do be installed correctly to ensure proper opera- installation instructions. not use substitute parts or vinyl electrical tape tion and to prevent shock or fire. Read these Component approvals and performance are to make connections. 2 AMC-F5 Installation Instructions Installing the Thermostat 1. Verify that the thermostat is suitable for 3. Mount the unit in a position that pre- the area where it is to be installed. vents condensation from draining into the enclosure from the connecting con- 2. Check the line voltage and the heat-trac- duit, (see diagram at left). MFD BY BARKSDALE CONTROLS FOR DigiTracve™ TEMP. MO. ® ing load to ensure that the thermostat R & REG. EQUIP. LISTED AMC-F5 FIXED SET POINT THERMOSTAT 22 AMPS @ 125, 250 & 480 VAC NEMA 4X SWITCH TYPE SP-DT SETPOINT: 40°F (5°C) DECREASING Chemelex Division Raychem Corporation Menlo Park, CA 94025-1164 ratings are not exceeded. Conduit drain Positioning (Ambient) 4. Mount ambient-sensing units in the tion that is exposed to warm air cur- area exposed to the coldest temperature rents or direct sunlight. and most wind. Do not mount on the side of a warm building or in a loca- Positioning the Sensor Bulb 5. Position the bulb in the lower quadrant 7. For metal-tank-wall sensing, use the (Line Sensing) of the pipe as shown in the diagrams to BCK-35 bulb clamp (purchased sepa- the left. Place the bulb at least three rately from Raychem) and install the feet from pipe supports, valves, or clamp per the instructions provided. Single traced other heat sinks; protect the capillary Make sure there is no air space 90° Heating cable from kinks or bends less than 1⁄2 inch between the tank wall and the bulb. Control thermostat bulb in radius. AT-180 tape For installation on plastic tanks, contact 6. Tape the bulb firmly to the pipe with AT- Tyco Thermal Controls at (800) 545-6258. 180 aluminum tape, making sure there is Double traced no air space between the bulb and pipe. Do not overlap the bulb and heating Heating cable Control thermostat bulb cable with the same piece of AT-180 AT-180 tape tape. Wiring Power Supply Power Supply GFEPD GFEPD 120-V supply – 120-V heating cable or Ø Ø 208-V or 240-V supply G N N N Ø Ø Ø A B C A B C 208-V supply – 240-V heating cable or G N Ø 120-V supply Purple wire C Control Purple thermostat wire NC Blue C Control wire thermostat C NC Blue wire 120-V or 240-V coil Power Thermostat bulb G connection (see "Positioning" instructions above Thermostat bulb mounting details) Braid (see "Positioning" instructions above Braid Heating mounting details) cable A Heating Heating cable B Cable Heating cable C Figure 1. Heat-tracing control Figure 2. Contactor control For switching heat-tracing loads greater than 22 A or switching multiple heat-tracing circuits. Worldwide Headquarters Important: All information, including illustrations, is believed to be reliable. Users, however, should Tyco Thermal Controls independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls 300 Constitution Drive makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding Menlo Park, CA 94025-1164 its use. Tyco Thermal Controls' only obligations are those in the Tyco Thermal Controls Standard Terms and USA Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for Tel(800) 545-6258 any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Fax (650) 474-7517 Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to Fax-on-Demand (800) 329-4494 make changes—without notification to Buyer—to processing or materials that do not affect compliance with any info@tycothermal.com applicable specification. www.tycothermal.com © 1995, 2001 Tyco Thermal Controls LLC Printed in USA PN 770995 H56912 10/01
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the AMC-F5 have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods