POWER-ONE MPU150/MDU150
Features
- Available with Metric or SAE Mountings
- Dual Main Outputs Provide 3.3V and 5V for Mixed Mode Applications
- Greater than 340,000 Hours MTBF
- Low Profile Height Fits 1U Constraints
- MDU150 Models have 48VDC Input
- Overtemperature, Overload, and Overvoltage Protection
- Power Factor Correction (PFC) Meets EN61000-3-2
- Remote Sense on Outputs V1 and V2
- Single Wire Current Sense on Outputs V1 and V2
Datasheet
Extracted Text
MPU150/MDU150 SERIES MPU150/MDU150 SERIES The innovative MPU products incorporate Power Factor Correction (PFC) with a All multiple output models feature remote sense on outputs V1 and V2 to provide low profile package designed to meet 1U height constraints. The MPU150-4530 independent compensation of output cable losses. Other standard features include and MPU150-4350 provide high current +3.3V and +5V on a single platform to independent current sharing on V1 and V2, thermal shutdown, and remote inhibit. support mixed mode, high speed digital circuitry. Power-One’s unique dual Airflow of 300 linear feet per minute (LFM) is required to deliver the full power converter architecture combines high reliability with exceptional regulation. density of 3.0 watts per cubic inch. The MDU150 series provides the same benefits as the MPU150 series, with nominal 48 volt DC input. FEATURES Power Factor Correction (PFC) Meets EN61000-3-2 Low Profile Height Fits 1U Constraints Dual Main Outputs Provide 3.3V and 5V for Mixed Mode Applications Single Wire Current Sense on Outputs V1 and V2 Remote Sense on Outputs V1 and V2 Overtemperature, Overload, and Overvoltage Protection Available with Metric or SAE Mountings Greater than 340,000 Hours MTBF MDU150 Models have 48VDC Input AC INPUT, SINGLE OUTPUT MODEL SELECTION CHART OUTPUT ADJUSTMENT MAXIMUM OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY MPU150-S259 12V 11.6V to 16V 15A (Note 3) 0.1% 1% 1% 11.97V to 12.03V MPU150-S262 24V 22.8V to 29.2V 7.5A (Note 3) 0.1% 1% 1% 23.95V to 24.05V MPU150-S261 48V 45V to 56V 3.75A (Note 3) 0.1% 1% 1% 47.9V to 48.1V AC INPUT, MULTIPLE OUTPUT MODEL SELECTION CHART – 150W WITH 300 LFM FORCED AIR COOLING ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY +3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V MPU150-3300 +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V +12V Fixed 2A 0.4% 3% 1% 11.76V to 12.24V +5V 5.0V to 5.5V 17.5A 0.4% 1% 1% 4.98V to 5.02V MPU150-3524 +12V 10.8V to 13.2V 4A 0.4% 3% 1% 11.94V to 12.06V +24V Fixed 2A 0.4% 3% 1% 23.52V to 24.48V +5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% 1% 4.98V to 5.02V +12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V MPU150-4000 12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V 5V 5.0V to 5.5V 2A 0.4% 1% 1% 4.98V to 5.02V +2.5V 2.25V to 3.0V 30A (Note 4) 0.8% 2% 2% 2.49V to 2.51V +3.3V 3.15V to 3.8V 15A (Note 4) 0.6% 1.5% 1.5% 3.28V to 3.32V MPU150-4230 12V 10.8V to 13.2V 4A (Note 5) 0.4% 1% 1% 11.94V to 12.06V 5V 5.0V to 5.5V 2A (Note 5) 0.4% 1% 1% 4.98V to 5.0V +3.3V 3.15V to 3.80V 30A (Note 4) 0.6% 1.5% 1% 3.28V to 3.32V +5V 5.0V to 5.5V 15A (Note 4) 0.4% 1% 1% 5.00V to 5.04V MPU150-4350 12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V +5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% 1% 4.98V to 5.02V +3.3V 3.15V to 3.60V 15A (Note 4) 0.6% 1.5% 1.5% 3.28V to 3.32V MPU150-4530 12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 4) Total current between V1 and V2 is 30A, maximum rating. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 5) Total current between V3 and V4 is 5A, maximum rating. 3) Total power of 180 Watts. REV. 09/01 1 MPU150/MDU150 SERIES MPU150/MDU150 SERIES DC INPUT MODEL SELECTION CHART – 150W WITH 300 LFM FORCED AIR COOLING ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY +3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V MDU150-3300 +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V +12V N/A 2A 0.4% 3% 1% 11.76V to 12.24V +5V 5.0V to 5.5V 30A (Note 3) 0.4% 1% 1% 4.98V to 5.02V +12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V MDU150-4000 12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V 5V 5.0V to 5.5V 2A 0.4% 1% 1% 4.98V to 5.02V +5V 5.0V to 5.5V 30A (Note 3) 0.4% 1% 1% 4.98V to 5.02V +3.3V 3.15V to 3.60V 15A (Note 3) 0.6% 1.5% 1.5% 3.28V to 3.32V MDU150-4530 12V 10.8V to 13.2V 3A (Note 4) 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A (Note 4) 0.4% 7% 1% 11.94V to 12.06V MPU150 INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at 150 watts. MPU150-4350 17.5 mS All other models 20 Input Current 85 VAC at full rated load. MPU150 3.0 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C. 35 APK Power Factor Per EN61000-3-2. 0.95 W/VA Operating Frequency Switching frequency of main output transformer. 100 120 Switching frequency of secondary transformer. 65 90 kHz Switching frequency of Power Factor Correction circuit. 60 MDU150 INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - DC Continuous input range. 36 75 VDC Brown Out Protection Lowest DC input voltage that regulation is maintained with full rated loads. 34 VDC Hold-up Time At 150 watts, over DC input range. 20 mS Input Current 36 VDC at full rated load. 6.4 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Vin = 72 VDC. 35 APK Operating Frequency Switching frequency of main output transformer. 100 kHz Switching frequency of secondary transformer. 70 NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 3) Total current between V1 and V2 is 30A, maximum rating. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 4) Total current between V3 and V4 is 5A, maximum rating. 2 MPU150/MDU150 SERIES OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. 65 75 % Minimum Load, V1 Minimum load required to maintain regulation on MPU150-3300, V1 4 A V2 at maximum load. All other models, V1 3 Minimum Load, V3 Minimum load required to maintain regulation on MPU150-3300, V3 N/A A V4 at maximum load. All other models, V3 0.3 Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Charts Output Power With 300 LFM forced air cooling. (Note 1) 150 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified. See Model Selection Charts input range, changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 500 µS 5% max. deviation. Turn-on Delay Time required for initial output voltage stabilization. 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Latch style overvoltage protection. Available on 2.5V output, V1 3.0 3.25 V1, V2, all models, and V3 on all models except 3.3V output, V1 4.1 4.65 MPU150-3300. 3.3V output, V2 3.8 4.2 5V output, V1, V2 6.0 6.4 V 12V output, V2 (Note 2) 14 16 MPU150-4350 3.3V output, V1 4.3 4.65 Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Output Good TTL compatible signal available for V1. Signal is high when 3.3V 3.16 output is within 5% of nominal. Signal shall remain low for 20 5V 4.75 V milliseconds following loss of Output Good. Input Power Fail Warning TTL compatible logic signal. Time before regulation dropout due to loss of input 5mS power. May be used as independent PSOK signal in redundant applications. Current Share Accuracy of shared current with up to 6 parallel units. Single wire current share 10 % on V1 and V2 with return via -Sense return. Remote Sense Available on V1 and V2. Total voltage compensation for cable losses with 500 mV respect to the main output. Inhibit Output voltage is inhibited by application of an external high (5V) signal. NOTES: 1) Overvoltage range for 12V, V3 outputs: 14V to 19V. SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 NO. 234/950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to output per EN60950. MPU150 2600 VDC MDU150 1544 Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. B Class EN55022 / CISPR 22 Conducted. B ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 3. ±2 kV Input Transient Protection Per EN61000-4-5, class 3. Line to Line 1 kV Line to Ground 2 Insulation Resistance Input to output. 10 M� Leakage Current Per EN60950. MPU150 at 264 VAC 1250 µA MDU150 at 72 VDC 100 NOTES: 1) This product is not rated for convection applications. 2) Overvoltage range for 12V, V3 outputs: 14V to 19V. 3 MPU150/MDU150 SERIES ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-Operating. 40k ASL Ft. Operating Temperature At 100% load 0 50 °C Derate linearly above 50°C by 2.5% per °C. At 50% load 0 70 °C Storage Temperature -55 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). ±0.02 ±0.05 %/°C Relative Humidity Non-Condensing. 5 95 %RH Shock Peak acceleration. 20 GPK Vibration Random vibration, 10Hz to 2kHz, 3 axis. 6 GRMS OPTIONS DESCRIPTION NOTES SIZE IMPACT Metric Mounting Add “M” as a suffix to the model number to order chassis with 8.00" x 4.20" x 1.50" M4 x 0.7 mounting inserts. (203.2mm x 106.7mm x 38.1mm) 4 MPU150/MDU150 SERIES OVERALL SIZE: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) WEIGHT: 2.0 LBS (0.89 kg) OUTPUTS: SINGLE OUTPUT 8-32 SCREW CONNECTIONS (4PL) +V1 RTN INTERFACE CONNECTIONS (J300) PIN V1,V. 10. +S, V1 ADJ. J1 INPUT 9. -S, V1 L 8. CURRENT SHARE, V1 7. NO CONNECTION N 6. NO CONNECTION 5. NO CONNECTION 4. OUTPUT GOOD, V1 3. POWER FAIL WARNING 2. INHIBIT 1. SIGNAL GROUND MOLEX SERIES 5268-NA, P/N: 22-05-7105, PINS ON 2.50mm CENTERS. MATES WITH MOLEX: HOUSING SERIES 5264-N, P/N: 50-37-5103 (&) PINS SERIES 5263, P/N: 80-70-1040 (LOOSE) M4 X 0.7, 8 PLACES. MAXIMUM TORQUE: 3.5 IN/LBS (0.40 N/M) MOLEX PIN PINS PINS WIRE CONNECTOR HOUSING CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, SERIES SERIES (LOOSE) (CHAIN) GAUGE 41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20AWG WITH CLEAR FINISH J1 41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20AWG (ALL MODELS) 2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20AWG J300 5264-N 50-37-5103 5263 08-70-1040 08-70-1039 22-28AWG 5 S MPU150/MDU150 SERIES OVERALL SIZE: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) WEIGHT: 2.0 LBS (0.89 kg) MOLEX PIN PINS PINS WIRE CONNECTOR HOUSING SERIES SERIES (LOOSE) (CHAIN) GAUGE 41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20AWG J1 41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20AWG (ALL MODELS) 2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20AWG CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, J2 5051-N 22-01-1022 2759 08-50-0114 08-50-0113 22-30AWG WITH CLEAR FINISH (TRIPLE OUTPUT) 5051-N 22-01-1022 2759 08-65-0805 08-65-0804 22-30AWG 41695 09-50-8021 6838 08-50-0189 08-50-0187 18-20AWG J3 41695 09-50-8021 2478 08-50-0106 08-50-0105 18-20AWG (TRIPLE OUTPUT) 2139 09-50-3021 2478 08-50-0106 08-50-0105 18-20AWG 41695 09-50-8061 6838 08-50-0189 08-50-0187 18-20AWG J3 41695 09-50-8061 2478 08-50-0106 08-50-0105 18-20AWG (QUAD OUTPUT) 2139 09-50-3061 2478 08-50-0106 08-50-0105 18-20AWG J300 5264-N 50-37-5103 5263 08-70-1040 08-70-1039 22-28AWG 6 This datasheet has been download from: www.datasheetcatalog.com Datasheets for electronics components.
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the MPU150/MDU150 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods