POWER-ONE MAP130-1005C
Features
- All outputs fully regulated
- Automatic 115/230 input voltage selection
- Greater than 100,000 Hour MTBF
- Metric and SAE mounting inserts
- Power Fail signal included
- Remote sense, overvoltage protection, andvovertemperature protection
- RoHS lead-solder-exemption compliant
- U-Channel chassis: 8.50" x 4.50" x 2.00" (215.9mm x 114.3mm x 50.8mm)
Datasheet
Extracted Text
MAP130 AC-DC Series Data Sheet Features • RoHS lead-solder-exemption compliant • Automatic 115/230 input voltage selection • All outputs fully regulated • Remote sense, overvoltage protection, and overtemperature protection • Power Fail signal included • Greater than 100,000 Hour MTBF • U-Channel chassis: 8.50" x 4.50" x 2.00" (215.9mm x 114.3mm x 50.8mm) • Optional cover • Metric and SAE mounting inserts Description Power-One’s MAP130 Series of single and multiple output power supplies provide fully-regulated outputs with high peak current capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis. Other standard features include autos- elect AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE mounting inserts. This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 °C. All products are approved to the latest international regulatory standards and display the CE Mark. Single Output Model Selection OUTPUT ADJUSTMENT CONTINUOUS PEAK LINE LOAD TYPICAL RIPPLE & INITIAL SETTING MODEL VOLTAGE RANGE CURRENT CURRENT (NOTE 3) REGULATION REGULATION NOISE %p-p (NOTE 1) ACCURACY MAP130-1005 5V 4.75V to 5.50V 26A 30A 0.2% 1% 1% 5.1V to 5.2V MAP130-1012 12V/15V 11.4V to 15.75V 12A/10A (Note 2) 13.8A/11A 0.2% 1% 1% 12.0V to 12.2V MAP130-1024 24V/28V 22.5V to 30.0V 6.2A/5.4A (Note 2) 6.8A/5.9A 0.2% 1% 1% 23.9V to 24.1V NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Multiple Output Model Selection – 130W Continuous Output Power OUTPUT ADJUSTMENT OUTPUT PEAK CURRENT LINE LOAD TYPICAL RIPPLE & INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION NOISE %p-p (NOTE 2) ACCURACY +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V +12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.75V to 12.0V MAP130-4000 -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V +24V 23.0V to 25.0V 3.5A 5A 0.5% 2% 1% 23.9V to 24.1V MAP130-4001 -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V +12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.9V to 12.1V MAP130-4002 -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V Model numbers highlighted in yellow or shaded are not recommended for new designs. MCD10115 Rev. 1.3, 05-Feb-10 Page 1 of 4 www.power-one.com MAP130 AC-DC Series Data Sheet Multiple Output Model Selection (Cont.) – 130W Continuous Output Power OUTPUT ADJUSTMENT OUTPUT PEAK CURRENT LINE LOAD TYPICAL RIPPLE & INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION NOISE %p-p (NOTE 2) ACCURACY +5V 4.75V to 5.50V 20A 30A 1% 1% 1% 5.1V to 5.2V +15V 14.0V to 16.0V 4A 8A 1% 2% 1% 15.0V to 15.1V MAP130-4003 -5V Fixed 1A 1A 2% 2% 1% -4.8V to -5.2V -15V Fixed 1A 1A 2% 2% 1% -14.7V to -15.3V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.15V to 5.2V +24V 23.0V to 25.0V 3.5A 5A 0.5% 2% 1% 23.9V to 24.1V MAP130-4004 -15V Fixed 1A 1A 0.5% 2% 1% -14.5V to -15.5V +15V Fixed 1A 1A 0.5% 2% 1% 14.5V to 15.5V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.25V +12V 11.5V to 12.8V 5A 10A 0.5% 2% 1% 11.75V to 12.0V MAP130-4010 -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V -12V Fixed 3A 3A 0.5% 2% 1% -11.6V to -12.4V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.25V +12V 11.5V to 12.8V 5A 10A 0.5% 2% 1% 11.75V to 12.0V MAP130-4020 -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V -5V Fixed 3A 3A 0.5% 2% 1% -4.8V to -5.2V NOTES: 1) Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.). 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. Model numbers highlighted in yellow or shaded are not recommended for new designs. Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage- AC Auto-ranging. Low Range 90 115 132 VAC High Range 175 230 264 Input Frequency AC Input. 47 63 Hz Brown out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC Hold-up Time Nominal AC input voltage (115 VAC). 130W load: 40 mS Input Current 90 VAC, 130W load. 3.3 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25° C. 38 APK Operating Frequency Switching frequency of main transformer (variable). Range: 16 120 kHz Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full Load, 115VAC. Varies with distribution of loads among outputs. 71 80 % Minimum Loads MAP130-1012. 1.25 MAP130-1024. 0.63 Amps MAP130-1005 and all multiple output models, main channel only. 3.00 Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart Output Power Continuous output power, all multiple output models. 130 Watts Peak output power (60s maximum, 10% duty cycle), all multiple output models. 165 Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on / turn-off 1 % Regulation Varies by output, Total regulation includes: line changes from 90-132 VAC See Model Selection Chart or 175-264, changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time to within 1% of initial set point due to a 50-100% load change, 500 µS 4% max. deviation. (Main output only on multi-output units) Turn-on Delay Time required for initial output voltage stabilization. 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS MCD10115 Rev. 1.3, 05-Feb-10 Page 2 of 4 www.power-one.com MAP130 AC-DC Series Data Sheet Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Provided on single output units and only MAP130-1012 17.0 22.0 the main output of multiple output units. MAP130-1024 32.0 37.0 VDC MAP130-4004 6.2 7.4 All other models. 5.5 6.8 Overcurrent Protection All models have inherent short circuit protection. Units will automatically restart at the removal of the fault. Remote Sense Total voltage compensation for main output cable losses. 250 mV Logic LO (denotes power fail detected). 0.7 V Power Fail Warning Logic HI with internal pull-up to output. 10 k� (Note 1) Power Fail trip point, maximum load, decreasing line. 86 94 VAC Time before regulation dropout, at full load, due to loss of input power. 5 mS Overtemperature Warning Warning prior to system shutdown due to excessive internal temperatures. 20 mS (Note 2) Shifts Power Fail signal to a logic LO state. NOTES: 1) Power Fail not available on MAP130-1012 and MAP130-1024. 2) MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature. Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 No. 234/950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to Output, 1 second. 2600 VDC Electromagnetic FCC CFR title 47 Part 15 Sub-Part B - Conducted B Interference, EN55022 / CISPR 22 Conducted B Class EN55022 / CISPR 22 Radiated (Note 1) B ESD Susceptibility Per EN61000-4-2, level 4 8 kV Radiated Susceptibility Per EN61000-4-3, level 3 10 V/M EFT/Burst Per EN61000-4-4, level 3 (Note 2) ±2 kV Input Transient Protection Per EN61000-4-5 class 3 Line to Line 1 kV Line to Ground 2 Insulation Resistance Input to output 7 M� Leakage Current Per EN60950 (264 VAC) 700 µA NOTES: 1) MAP130-1005 meets Class A, radiated. 2) MAP130-1005, MAP130-4003, and MAP130-4010, meet level 2, ±1kV. Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating 10K Feet Non-Operating 40K Operating Temperature At 100% load: 0 50 °C Derate linearly above 50°C by 2.5% per °C At 50% load: 70 °C Storage Temperature -40 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up period) ±0.02 ±0.05 %/°C Relative Humidity Non-Condensing 5 95 %RH Shock Operating, peak acceleration 20 GPK Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS Options DESCRIPTION NOTES DIMENSIONS Cover Add ‘C’ suffix to model number or order part number 412-59586-G separately. For convection cooled applications with covers, derate output power as follows: 8.50" x 4.50" x 2.40" Derate all multiple output models and MAP130-1005 to 120 watts. (215.9mm x 114.3mm x 61.0mm) Derate MAP130-1012 and MAP130-1024 to 140 watts. MCD10115 Rev. 1.3, 05-Feb-10 Page 3 of 4 www.power-one.com MAP130 AC-DC Series Data Sheet OVERALL SIZE: 8.50" x 4.50" x 2.00" (215.9mm x 114.3mm x 50.8mm) WEIGHT: 2.5 lb (1.13 kg) INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.96mm) CENTERS; MATES WITH MOLEX SERIES 2139, 6442, & 41695 POWER FAIL CONNECTIONS, J2: 0.035" (0.89mm) SQUARE PINS ON 0.100" (2.54mm) CENTERS; MATES WITH MOLEX SERIES 2695 & 6471 CHASSIS: 0.090" (2.286mm) ALUMINUM ALLOY WITH CLEAR FINISH NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10115 Rev. 1.3, 05-Feb-10 Page 4 of 4 www.power-one.com
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the MAP130-1005C have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods