Elite.Parts chervon right Manufacturers chervon right O chervon right OPTO 22 chervon right M4SARCFR
About product Specifications Datasheet FAQ

OPTO 22 M4SARCFR

Image of OPTO 22 M4SARCFR

Description

Opto22 M4SARCFR Interface Controller - Computers, Interface cards

Part Number

M4SARCFR

Price

Request Quote

Manufacturer

OPTO 22

Lead Time

Request Quote

Category

PRODUCTS - M

Specifications

Address range

1 to 255,0

Connector

ST

Indicators

Single LED; lights when the controller is actively communicating on the ARCNET network, and during controller initialization upon reset.

Maximum cable length between Opto 22 devices

16,000 ft. (approx. 3 miles)

Maximum repeaters on fiber segment (including hubs)

5

Power requirement (at 5 VDC)

220 mA

Receiver characteristics (typical)

Receiver sensitivity Equivalent numerical aperture Optical port diameter -24 dBm 0150 400 mm

Recommended fiber optic cable

Belden P/N 225812 (duplex) Belden P/N 225811 (single, two required)

Recommended fiber size

62.5/125µm

Storage Temperature

-40°C to 85°C

Topology

Star and multidrop

Transfer Rate

2.5 Mb/sec

Transmitter characteristics (typical)

Optical power output Peak emission wavelength Numerical aperture Optical port diameter -10 dBm 820 mm 0.31 150 mm

Typical operating temperature

-20°C to 70°C

Datasheet

pdf file

Opto220-M4SARCF-Datasheet-415935822.pdf

198 KiB

Extracted Text

INTERFACES CONTROLLERS MODULAR DATA SHEET page 1/6 Form 673-010412 Part Number Description M4SARCF M4 ARCNET Adapter Fiber Optic Description M4SARCFR M4 ARCNET Repeater Fiber Optic The M4SARCF adapter and M4SARCFR repeater are fiber Primary Function ® optic ARCNET network interface cards for Opto 22’s M4 family Opto 22 M4SARCF and M4SARCFR cards provide a primary of modular controllers. These interface cards provide the capability transmit and receive channel on a fiber optic ARCNET network. to construct a point-to-point, star, or multidrop topology fiber optic Either two single-fiber optic cables or one duplex fiber optic cable ARCNET network using 62.5/125 micrometer fiber-optic cable and can be used for connections between a PC, active hubs, and M4- ST-style connectors. family controllers. Active fiber optic ARCNET hubs can be used to When installed in an Opto 22 M4-family controller such as establish a star topology Opto 22 controller network. The the M4RTU or the SNAP-LCM4, the M4SARCF and M4SARCFR M4SARCFR contains a built-in repeater to repeat the signal back interface cards provide fiber optic ARCNET connections to form to the network for multidrop configurations. the physical layer of an Opto 22 controller network. For additional Using Opto 22 M4SARC, M4SARCF, and M4SARCFR ARCNET ARCNET connectivity, Opto 22’s M4DUALARC twisted-pair interface cards, plus the appropriate PC and active hub equipment, ARCNET card can be installed concurrently with the M4SARCF or you can construct an extensive Opto 22 controller network consisting M4SARCFR cards in the same M4-family controller. of both coaxial and fiber optic ARCNET. M4SARCF Network Interface Card M4SARCFR Network Interface Card Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • E-mail: sales@opto22.com INTERFACES CONTROLLERS MODULAR DATA SHEET page 2/6 Form 673-010412 Description (continued) One Opto 22 controller network can support up to 255 M4- data at 2.5 Mbps and allows longer total network distances than family and other Opto 22 controllers. An Opto 22 controller network coaxial ARCNET. also supports peer-to-peer communications between all controllers The high noise immunity and electrically isolated properties of on the network. More than one Opto 22 controller network can be fiber optic cable provide a highly robust Opto 22 controller network linked to a single PC, allowing you to develop large, distributed ideal for noisy and/or hazardous environments, such as electrical control systems. substations, co-generation plants, and oil platforms. Advantages Software Speed, distance, noise immunity and electrical isolation are The M4SARCF and M4SARCFR interface cards are designed the significant advantages of an Opto 22 controller network based to work with FactoryFloor, Opto 22’s powerful suite of 32-bit ® ® on fiber optic ARCNET. A fiber optic ARCNET network transfers industrial automation software for Microsoft Windows 95, Specifications Item Specification Transfer rate 2.5 Mb/sec. Address range 1 to 255 Recommended fiber size 62.5/125 µm Recommended fiber optic cable Belden P/N 225812 (duplex) Belden P/N 225811 (single, two required) Connector ST Topology Star and multidrop 1 Maximum cable length between Opto 22 devices 16,000 ft. (approx. 3 miles) Maximum repeaters on fiber segment 5 (including hubs) Transmitter characteristics (typical): Optical power output -10 dBm Peak emission wavelength 820 mm Numerical aperture 0.31 Optical port diameter 150 mm Receiver characteristics (typical): Receiver sensitivity -24 dBm Equivalent numerical aperture 0150 Optical port diameter 400 mm Power requirement (at 5 VDC) 220 mA Typical operating temperature -20° C to 70° C Storage temperature -40° C to 85° C Indicators Single LED; lights when the controller is actively communicating on the ARCNET network., and during controller initialization upon reset. 1 If you are using an active hub, consult the hub specifications for maximum link distances. Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • E-mail: sales@opto22.com INTERFACES CONTROLLERS MODULAR DATA SHEET page 3/6 Form 673-010412 Description (continued) ® Windows 98, and Windows NT . FactoryFloor consists of four integrated components: ™ ™  OptoControl , a graphical, flowchart-based  OptoServer , a robust, OPC-compliant data server that development environment for machine control and connects the controller network with the PC network ™ process applications  OptoConnect , a bidirectional link between the Opto 22 ™  OptoDisplay , an intuitive, shared database, human- database in the controller and Microsoft’s SQL Server machine interface (HMI) and trending package, including and Access databases. alarming M4SARCR and M4SARCFR System Architecture Important: The Opto 22 controller network is not a generic ARCNET local area network (LAN). It is a controller bus intended to support Opto 22 PC-based industrial automation equipment. Trying to support general LAN functions such as PC-to- M4SARC and PC file transfers over the controller network may or M4SARCFR Network may not yield satisfactory results. Configuration Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • E-mail: sales@opto22.com INTERFACES CONTROLLERS MODULAR DATA SHEET page 4/6 Form 673-010412 Installation Opto 22 M4SARCF and M4SARCFR interface cards can be 2. Select an unused M4BUS expansion slot and remove installed in an M4-family controller with the M4DUALARC the end cap. End caps are located below the serial ARCNET card. connectors, as shown in the illustration below. Warning: Do not use the fiber optic connectors on the card Each end cap is held in place by two screws located as handles when installing or removing the M4SARCF or on the side panel, adjacent to each end cap. Save these M4SARCFR interface card. screws after you remove them. To correctly align the Note: Do not install IRQ jumpers on the M4SARCF or interface card, you may need to remove additional end M4SARCFR card. Although there are several interrupt jumpers caps from the controller. labeled BIRQ, interrupt functions are not used. 4. Align the edges of the interface card with the U-channels on the sides of the selected expansion slot, Inserting the Card in an M4-Family and then slide the card in until it is seated firmly in the Controller (except SNAP-LCM4) M4BUS connector. 5. Use the screws from the original end cap to attach the 1. Turn off the controller. end cap included with the M4SARCF or M4SARCFR to the M4-family controller. M4RTU Controller Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • E-mail: sales@opto22.com INTERFACES CONTROLLERS MODULAR DATA SHEET page 5/6 Form 673-010412 Installation (continued) Inserting the Card in a SNAP-LCM4 5. Use the thumbscrews from the original cover plate to Controller attach the cover plate included with the M4SARCF or M4SARCFR to the SNAP-LCM4 controller. 1. Turn off the controller. 2. Select an unused M4BUS expansion slot and remove Setting ARCNET Host Port Jumpers the cover plate. Cover plates are located to the left of To configure your controller to use an Opto 22 ARCNET the serial connectors on the top of the SNAP-LCM4, as interface card, change controller jumper settings to match those shown in the illustration below. Each cover plate is held shown in the table “Controller Jumper Settings for ARCNET Host in place by two thumbscrews. Save these thumbscrews Port.” after you remove them. Warning: Jumpers must be set correctly for the ARCNET 4. Align the edges of the interface card with the interface card to operate. Verify your jumper settings carefully U-channels on the sides of the selected expansion slot, before turning on the controller. and then slide the card in until it is seated firmly in the M4BUS connector. SNAP-LCM4 Controller Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • E-mail: sales@opto22.com INTERFACES CONTROLLERS MODULAR DATA SHEET page 6/6 Form 673-010412 Installation (continued) Connecting the Controller to a The host jumpers on the controller determine which port is Network used for communication with the host when the controller is powered up or reset. Only the lowest numbered ARCNET port in To connect the M4-family controller to an Opto 22 controller the controller can be a host port. For example, if an M4SARCF or network, attach 62.5/125 micrometer fiber optic cable with ST- M4SARCFR fiber optic ARCNET card and an M4DUALARC twisted- style connectors to the Transmit (TX) and Receive (RX) connectors pair ARCNET card are both installed in a controller (with host port on the M4SARCF or M4SARCFR card. jumpers set for ARCNET), the fiber optic ARCNET port on the When you connect devices on a fiber-optic ARCNET network, M4SARCF card will be the host port because it has the lowest make sure the TX connector of one device connects to the RX ARCNET port number (4). connector of the next device on the network. Likewise, make sure If an M4-family controller has jumper settings configured for the RX connector of one device connects to the TX connector of the ARCNET, but an ARCNET card is not installed, COM0 will be the next device on the network. Incorrectly connecting TX and RX host port by default. connectors will prevent your network from operating correctly. Recommended ARCNET Networking Hardware Controller Jumper Settings Opto 22 recommends ARCNET cards and networking for ARCNET Host Port components from the following manufacturer: All M4-Family Contemporary Control Systems, Inc. (CCSI) Controllers 2431 Curtiss Street Downers Grove, IL 60515 Jumpers Phone: (630) 963-7070 H0 H1 FAX: (630) 963-0109 COM0 In In E-mail: info@ccontrol.com Web: www.ccontrol.com (or www.ccontrols.com) COM1 Out In See Opto 22 form 1294 for more information about using ARCNET In Out Contemporary Control Systems ARCNET equipment with Opto 22 products, or contact Opto 22 Product Support. Contact information Out Out Ethernet appears at the bottom of the page. Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • E-mail: sales@opto22.com © 1994–2001 Opto 22. All rights reserved. All trademarks, trade names, logos, and service marks referenced herein belong to their respective companies. LATEST PRODUCTS PRODUCT SUPPORT INTERFACES COMPANY INFORMATION CONTROLLERS MODULAR Opto 22 Software Products DATA SHEET page 7/6 ® Opto 22’ s ioProject and FactoryFloor software Opto 22 produces a broad array of reliable, flexible hardware and Form 673-010412 software products for industrial automation, remote monitoring, enterprise suites provide full-featured and cost-effective control, HMI, and OPC software to power your data acquisition, and machine-to-machine (M2M) applications. Opto 22 hardware. These software applications SNAP Ethernet Systems help you develop control automation solutions, build Based on the Internet Protocol (IP), SNAP Ethernet systems offer easy-to-use operator interfaces, and expand your flexibility in their network connectivity and in the software applications manufacturing systems’ connectivity. they work with. The physical network may be a wired Ethernet network, a cellular wireless network, or a modem. A wide variety of software Quality applications can exchange data with SNAP Ethernet systems, including: In delivering hardware and software solutions for worldwide device  Opto 22’s own ioProject™ suite of control and HMI software management and control, Opto 22 retains the highest commitment to  Manufacturing resource planning (MRP), enterprise quality. We do no statistical testing; each product is made in the U.S.A. management, and other enterprise systems and is tested twice before leaving our 160,000 square-foot manufacturing  Human-machine interfaces (HMIs) facility in Temecula, California. That’s why we can guarantee solid-state  Databases relays and optically-isolated I/O modules for life.  Email systems  OPC client software Product Support  Custom applications Opto 22’s Product Support Group offers comprehensive technical  Modbus/TCP software and hardware. support for Opto 22 products. The staff of support engineers represents SNAP Ethernet system hardware consists of controllers and I/O units. years of training and experience, and can assist with a variety of project Controllers provide central control and data distribution. I/O units provide implementation questions. Product support is available in English and local connection to sensors and equipment. Spanish from Monday through Friday, 7 a.m. to 5 p.m. PST. SNAP OEM Systems Opto 22 Web Sites Opto 22 SNAP OEM I/O systems are highly configurable, programmable  www.opto22.com processors intended for OEMs, IT professionals, and others who need to  nvio.opto22.com use custom software with Opto 22 SNAP I/O modules.  www.internetio.com (live Internet I/O demo) ® Linux applications running on these systems can read and write to analog, simple digital, and serial Other Resources I/O points on SNAP I/O modules using easily  OptoInfo CDs implemented file-based operations. Applications can  Custom integration and development be developed using several common development  Hands-on customer training classes. tools and environments, including C or C++, Java, and shell scripts. About Opto 22 Opto 22 manufactures and develops hardware and software products M2M Systems for industrial automation, remote monitoring, enterprise data acquisition, Machine-to-machine (M2M) systems connect your business computer and machine-to-machine (M2M) applications. Using standard, systems to the machines, devices, and environments you want to monitor, commercially available Internet, networking, and computer technologies, control, or collect data from. M2M systems often use wireless cellular Opto 22’s input/output and control systems allow customers to monitor, communications to link remote facilities to central systems over the Internet, control, and acquire data from all of the mechanical, electrical, and or to provide monitoring and control capability via a cellular phone. electronic assets that are key to their business operations. Opto 22’s Opto 22’s Nvio™ systems include everything you need for M2M— products and services support automation end users, OEMs, and interface and communications hardware, data service plan, and information technology and operations personnel. Web portal—in one easy-to-use package. Visit nvio.opto22.com for Founded in 1974 and with over 85 million Opto 22-connected devices more information. deployed worldwide, the company has an established reputation for quality and reliability. Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • E-mail: sales@opto22.com Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • Email: sales@opto22.com • Form 1335-050601 © 2004-2005 Opto 22. All rights reserved. All trademarks, trade names, logos, and service marks referenced herein belong to their respective companies.

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the M4SARCFR have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

M4 Dual ARCNET Adapter Card

product

Opto22 M4DUALARC M4 Dual ARCNET Adapter Card

product

OPTO22 MP120D2 Relays-120 VAC, 2 Amp, DC Control Solid State Relay

product

OPTO22 MP240D2 Relays-240 VAC, 2 Amp, DC Solid State Relay

product

OPTO22 MP240D4 Relays-240 VAC, 4 Amp, DC low profile Solid State Relay

product

OPTO22 MP380D4 Relays-380 VAC, 4 Amp, DC