OMRON E5CS-Q1KJX-F
Specifications
Alarm output
Type: SPST-NO relay, Max. load: 1 A, 250 VAC (resistive load), Setting range: Absolute value alarm: Same as control output setting range, Others: 0 to full scale
Ambient temperature
Operating -- 1 0°C to 55°C (14°F to 131°F), Storage -- 2 5°C to 65°C ( --13°F to 149°F)
Approvals
UL Recognized, File Number E68481, CSA Certified, File Number LR59623 CE Conforms to EN61010-1
Connections
Screw terminals
Contact
Type: SPDT relay, Max. load: 3 A, 250 VAC (resistive load)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminals of different polarity
Display
2 seconds for displayed indication to change
Display range
--999 to 999 (limited to input type)
Enclosure rating
Front panel: IP50, NEMA 4 with optional Y92A-48N waterproof cover, Rear panel: IP30, Terminals: IP00
Humidity
35 to 85% RH
Hysteresis
0.2% of full scale during ON/OFF control action
Indication accuracy
±0.5% of full scale, ±1 digit max.
Insulation resistance
20 M? minimum at 500 VDC
Malfunction durability
100 m/s, in 6 directions, 3 times each
2 to 55 Hz, 2 G in X, Y, and Z directions for 10 minutes each
Materials
Plastic case
Mechanical durability
10 to 55 Hz, 0.75 mm (0.03 in) double amplitude in X, Y, and Z directions for 2 hours each
30 m/s, in 6 directions, 3 times each
modes
Control Modes
Mounting
Fits 1/16 DIN panel cutout; includes panel mounting adapter
Power consumption
Approx. 7 VA
Proportional band
3% to 20% (in PID mode) automatically adjusted according to the rise time of the controlled system
Proportional period
2 or 20 seconds, switch selectable
Rate time
0.4 minutes (in PID mode)
Reset time
4 minutes (in PID mode)
Response time
Output 2 seconds for output to change
Sampling period
500 ms
Sensor input type
Thermocouple Type J (IC) and Type K (CA)
Service life
Mechanical: 10 million operation minimum with contact output, Electrical: 100,000 operations minimum with contact output
Setting accuracy
Set value coincides with indicated value, so no relative error exists
Supply voltage
100 to 240 VAC, 50/60 Hz; operates on 85 to 110% of rated voltage
Type
ON/OFF and PID with automatic tuning of proportional band, switch selectable
Voltage
Logic load: 12 VDC, 20 mA with short-circuit protection
Weight
170 g (6 oz.) without mounting adapter
Features
- 3-year warranty
- 8-function alarm, standard.
- Accurate to ±0.5% of full scale.
- Easy-to-read 11 mm high LED display.
- Field-selectable temperature ranges in °F and °C.
- Multiple temperature scale ranges allow flexibility to match application.
- Nonvolatile memory backup.
- Selectable ON/OFF and PID control with auto-tuning of proportional band.
- Tamper-proof setting, faulty sensor compensation and controller diagnostics.
Datasheet
Extracted Text
� Temperature Controller E5CS-X 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes � Accurate to ±0.5% of full scale � Multiple temperature scale ranges allow flexibility to match application � Field-selectable temperature ranges in °F and °C � Selectable ON/OFF and PID control with auto-tuning of proportional band � 8-function alarm, standard �� � Tamper-proof setting, faulty sensor compensation and controller diagnostics � Easy-to-read 11 mm high LED display � Nonvolatile memory backup � 3-year warranty Ordering Information � TEMPERATURE CONTROLLERS Item Part number Sensor input type Thermocouple Platinum RTD (Pt: 100 Ω, Interchangeable thermistor (Types J and K) DIN and JIS standards) (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F Temperature Ranges Thermocouple Input Type Input type Type K Type J Temperature range 0 to 200 0 to 300 0 to 400 0 to 500 0 to 600 0 to 999 0 to 999 0 to 200 0 to 300 0 to 400 0 t0 500 Scale indication °C °C °C/°F °C/°F °C/°F °C/°F °F °C °C °C/°F °C/°F Unit of measure 1° C or F Platinum RTD Input Type Temperature range –50 to 50 0.0 to 50.0 –20 to 80 0.0 to 99.9 0 to 200 0 to 300 0 to 400 0 to 600 0 to 800 Scale indication °C °C °C °C/°F °C/°F °C °C/°F °F °F Unit of measure 1° C or F 0.1° C or F 1° C or F 0.1° C or F 1° C or F Thermistor Input Type Temp. range –50 to 50 0 to 100 50 to 150 100 to 200 150 to 300 –50 to 100 0 to 200 100 to 300 200 to 400 300 to 600 Scale indication °C °F Unit of measure 1° C or F 37 E5CS-X E5CS-X � ACCESSORIES (ORDER SEPARATELY) Description Part number Protective cover Hard plastic; protects front panel against dust, dirt and water drops Y92A-48 Panel mounting adapter Replacement for one supplied with each unit Y92F-30 Specifications Part number E5CS-�1KJX E5CS-�1PX E5CS-�1GX Sensor input type Thermocouple Platinum RTD (Pt: 100Ω) Thermistor Type J (IC) and Type K (CA) DIN or JIS standard (interchangeable type) Supply voltage 100 to 240 VAC, 50/60 Hz; operates on 85 to 110% of rated voltage Power consumption Approx. 7 VA Control Contact Type SPDT relay output Max. load 3 A, 250 VAC (resistive load) Voltage Logic load 12 VDC, 20 mA with short-circuit protection Hysteresis 0.2% of full scale during ON/OFF control action Response Output 2 seconds for output to change time Display 2 seconds for displayed indication to change Service life Mechanical 10 million operation minimum with contact output Electrical 100,000 operations minimum with contact output Alarm output Type SPST-NO relay Max. load 1 A, 250 VAC (resistive load) Setting range Absolute value alarm: Same as control output setting range Others: 0 to full scale Setting accuracy Set value coincides with indicated value, so no relative error exists Indication accuracy ±0.5% of full scale, ±1 digit max. Display range –999 to 999 (limited to input type) Control Type ON/OFF and PID with automatic tuning of proportional band, switch selectable modes Proportional band 3% to 20% (in PID mode) automatically adjusted according to the rise time of the controlled system Reset time 4 minutes (in PID mode) Rate time 0.4 minutes (in PID mode) Proportional period 2 or 20 seconds, switch selectable Sampling period 500 ms Materials Plastic case Mounting Fits 1/16 DIN panel cutout; includes panel mounting adapter Connections Screw terminals Weight 170 g (6 oz.) without mounting adapter Enclosure ratings Front panel IP50, NEMA 4 with optional Y92A-48N waterproof cover Rear panel IP30 Terminals IP00 Approvals UL Recognized, File Number E68481 CSA Certified, File Number LR59623 CE Conforms to EN61010-1 Ambient temperature Operating –10°C to 55°C (14°F to 131°F) Storage –25°C to 65°C (–13°F to 149°F) Humidity 35 to 85% RH Insulation resistance 20 MΩ minimum at 500 VDC Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminals of different polarity Vibration Mechanical durability 10 to 55 Hz, 0.75 mm (0.03 in) double amplitude in X, Y, and Z directions for 2 hours each Malfunction durability 2 to 55 Hz, 2 G in X, Y, and Z directions for 10 minutes each 2 Shock Mechanical durability 30 m/s , in 6 directions, 3 times each 2 Malfunction durability 100 m/s , in 6 directions, 3 times each 38 E5CS-X E5CS-X Nomenclature 1. Main 9. Deviation indicators display 2. Control output indicator 8. Display data identifier 3. Alarm indicator 4. Up key 7. Write protection key 6. Return key 5. Down key Key Description Key Description 7 The hidden write protection key provides protection against 1 Main display sequentially displays the present unauthorized setting of temperature and is used in conjunc- temperature, set temperature, and an alarm value each time the return key is pressed. tion with the internal “protection” switch. If the internal protection switch is set to ON, then to obtain Up and Down 2 Control output indicator lights when the output is ON. operation, the hidden key must be pressed simultaneously 3 Alarm indicator lights when the alarm output is ON. with the Up and Down keys. If the internal protection switch with the Up and Down keys. If the internal protection switch is set to OFF, changes can be made simply by pressing the 4 Up key increases the set temperature or alarm value when Up and Down keys. pressed. Increases the value quickly when held down. 5 Down key decreases the set temperature or alarm value 8 Display data identifier lights SP when the set temperature is when pressed. Decreases the value quickly when held displayed on the main display and AL when an alarm value down. is displayed. 6 Return key changes the value displayed on the main 9 Red deviation indicators light up an arrow when the present display each time pressed. temperature is higher than the set temperature and light a down arrow when the present value is lower than the set temperature. The green block indicates the temperature deviation is within ±1% of the full scale. Dimensions 106 (4.2) Unit: mm (inch) 6 10 90 (3.54) (0.24) (0.39) 48 (1.89) Panel Cutout Side-by-side Mounting of Several Temperature Controllers +0.6 45 Controllers 2 3 4 5 6 –0 (1.77) +0.6 +1 +1 +1 +1 +1 +0.6 45 –0 L 93.5 141.5 189.5 237.5 285.5 45–0 –0 –0 –0 –0 –0 (1.77) (1.77) (3.68) (5.57) (7.46) (9.35) (11.24) Max. 60 Note: 1. Recommended panel thickness is 1 to 8 mm (0.04 to (2.36) L = 48 x number of units – 2.5 (1.89 x number of units –0.1) 0.31 in). 2. Because mounting brackets are attached to the top and bottom of a temperature controller, tight side-by- side mounting is possible. 39 E5CS-X E5CS-X Connections Voltage output type 20 mA, 12 VDC Contact output type 100 to 240 VAC, 50/60 Hz Thermocouple input type Alarm output Platinum RTD input type Thermistor input type Operation Temperature range selector switch � SETTINGS BEFORE APPLYING POWER Note: Always turn off the power supply to the temperature control- Alarm mode selector switch ler before changing any switch settings. Protection switch Before applying power to the temperature controller, set the following selector switches to specify the temperature range, functions and alarm mode. Control mode selector switch � ACCESS TO INTERNAL SWITCHES AND SELECTORS Push the tab on the underside of the front panel as you draw out Left side view Right side view the internal mechanism from the housing. The temperature range selector, and the alarm mode selector must all be set. A Select the desired temperature range by using the temperature range selector switch (rotary DIP type). The other rotary DIP protection switch can also be set to protect settings. The following diagrams show the locations of these switches on the switch is used to select one of eight alarm functions. Be sure the set temperature and alarm values are within the new range. internal mechanism. Otherwise, the temperature controller automatically shifts these values to the maximum or minimum of the newly-set temperature range. The protection switch may be used in conjunction with the front panel “hidden key” to prevent unauthorized changes to temperature settings. The switch is ON when it is pushed inwards in the direction of the white arrow. The function selector switch is a 8-pin in-line DIP switch on the other side of the internal mechanism. Use it to select ON/OFF or PID control action, proportional period, control output, input shift function, temperature sensor input standard and scale indication for dual-scale temperature ranges. 40 E5CS-X E5CS-X ON � FUNCTION SELECTOR SWITCH ON The function selector switch is a 6-pin in-line DIP switch. The following table shows the selection made by each switch position. PX16 2 3 4 5 Function Switch number P X 1 2 3 4 5 6 Key protection for Enables protection ON Up/Down keys Disables protection OFF Used for factory-authorized Not used in normal ON calibration only operation OFF Control mode PID action ON ON/OFF action OFF Proportional period 2 seconds ON 20 seconds OFF Control output Normal ON Reverse OFF Input shift function Enabled ON Disabled OFF RTD sensor input standard DIN ON JIS OFF Scale indication for dual- °F ON scale range selection °C OFF � CONTROL MODE SELECTION ON/OFF Action PID Action Switch 1 of the function selector DIP switch is factory-set to OFF, Set switch 1 of the function selector DIP switch to ON to perform so the temperature controller performs ON/OFF control PID control action. Follow the steps described below action.Set switch 3 to ON when the temperature controller is Determining Proportional Period used to control a cooling device such as a chiller or freezer. Set switch 2 of the function selector DIP switch to OFF to select a ON proportional period of 20 seconds. This is used when the PID ON control action is performed with the contact output of the temperature controller, or when using an external relay or contactor. PX16 2 3 4 5 ON Switch 1 OFF: ON Temperature controller performs ON/OFF action. Control output ON OFF PX16 2 3 4 5 Set temperature Switch 2 OFF: Proportional period is 20 seconds. ON Control ON ON output OFF 20 seconds When a quick response in required, set switch 2 to ON to select a PX16 2 3 4 5 proportional period of 2 seconds. Even when a solid state relay Switch 3 ON: Used for cooling operations in ON/OFF action. (SSR) is used, set the 2-second proportional period only when quick response is essential. Avoid using this setting with a Control output ON contact output because it will shorten the relay’s service life. OFF ON ON Set temperature PX16 2 3 4 5 Switch 2 ON: Proportional period is 2 seconds. Control ON output OFF 2 seconds 41 E5CS-X E5CS-X Determining Control Output Operation ON ON If the temperature controller is used to control a heater, the con- trol output can be set to perform a reverse (inverted) operation. Set switch 3 of the control output mode selector switch to OFF PX16 2 3 4 5 ON ON Switch 4 ON: Input shift function enabled. Fine adjustment of the temperature indication and the resulting controlled temperature is possible without changing or affecting PX16 2 3 4 5 the set point. Switch 3 OFF: The input shift value can be set within the range from –99.9 to 99 Controller performs reverse operation used with heaters. (°F or °C). Reverse ON For ranges that have resolution to 0.1, the input shift value can output OFF be set within the range from –9.9 to 9.9 (°F or °C. The input shift function may be useful to make small temperature corrections to Set temperature the control system. By contrast, if the temperature controller is used to control a Note that the offset value remains effective even after switch 4 cooling device such as a chiller or freezer, set switch 3 to ON. has been set to OFF. If the compensation action is not needed, ON be sure to set the offset value to 0. ON For example: � correction of known sensor calibration errors PX16 2 3 4 5 � correction of known steady temperature offset between the Switch 3 ON: Controller performs normal operation for heated work piece (load) and sensor. This is useful for cooling. applications where the sensor cannot be located exactly at Normal ON the work piece. output OFF � alignment of temperature indications in a Set temperature multi-zone/multi-controller application, e.g., at ambient temperature Auto-tuning of Proportional Band Note that the input shift changes the value of the controlled Upon the initial power-up the proportional band is set to 3%. The temperature when used in closed loop control. For example, with optimum proportional band width, however, is automatically a set point and indication of 100°C and input shift set at +10°C, calculated and set within the range of 3 to 20%, according to the the controlled temperature will be 90°C. changes in the temperature of the controlled system. This automatic adjustment of the proportional band is performed Main Set input Temperature Displayed regardless of whether the controlled system is a heating or display shift value measured by temperature cooling system. sensor When the power is turned OFF once, and the ON again, the con- 0 offset 100°C 100°C ��� trol action starts with the previous proportional band. However, offset by +9° 100°C 109°C ��� the new proportional band is automatically calculated and set. offset by –9° 100°C 91°C ��� The calculation of the proportional band, however, is not carried out if the temperature of the controlled system changes at a faster rate than 7.5% of full scale per 2 seconds (e.g., faster then � MATCHING THE CONTROLLER TO 3.75% per °C per second with eh full scale of 100°C). In this SENSOR STANDARD case, the previously calculated and set proportional band is used. Use switch 5 of the function selector DIP switch to match the The temperature controller has an overshoot suppression controller to the thermocouple or RTD sensor to be used. function that reduced second and subsequent overshoots to a level less than the initial overshoot. With switch 5 ON, the controller will accept DIN standard sensors. With switch 5 OFF, the controller accepts JIS standard sensors. � INPUT SHIFT FUNCTION The temperature indication can be shifted by setting switch 4 of � SELECTING SCALE INDICATION the function selector DIP switch to ON, and pressing the mode Some dual-scale (°C/°F) temperature scale ranges may be key repeatedly until the message “H0” (indicating ) input shift) is selected by rotary DIP switch. To specify the scale indication to displayed on the main display. Then set the shift value by using be displayed, used switch 6 on the in-line function selector DIP the Up or Down key. switch. With switch 6 set to ON, the controller displays Fahrenheit scale. With switch 6 set to OFF, the controller displays Celsius scale. 42 E5CS-X E5CS-X � SELECTING A SCALE RANGE Use the rotary DIP switch to select the temperature scale range. changed to the maximum or minimum value of the newly set The tables below show the switch setting number for each range. temperature scale range. The temperature indication range is the set temperature range If the alarm value is shifted outside the temperature scale range (full scale) ±10%, unless otherwise noted. as a result of changing the scale range, it is automatically If the set temperature is shifted outside of changing the scale changed to the maximum value of the newly set scale range. range, the set temperature is displayed. It is then automatically Thermocouple Input Type Thermocouple input models are factory-set to switch position 2 for a temperature range of 0° to 400°, using a type K thermocouple. Switch setting 0 1 2 3 4 5 6 6 7 8 9 Temperature range 0 to 200 0 to 300 0 to 400 0 to 500 0 to 600 0 to 999 0 to 999 0 to 200 0 to 300 0 to 400 0 t0 500 Scale indication °C °C °C/°F °C/°F °C/°F °C/°F °F °C °C °C/°F °C/°F Unit of measure 1° C or F Platinum RTD Type Platinum RTD input models are factory-set to switch position 3 for a temperature range of 0.0° to 99.9°. Switch setting 0 1 2 3 4 5 6 7 8 Temperature range –50 to 50 0.0 to 50.0 –20 to 80 0.0 to 99.9 0 to 200 0 to 300 0 to 400 0 to 600 0 to 800 Scale indication °C °C °C °C/°F °C/°F °C °C/°F °F °F Unit of measure 1° C or F 0.1° C or F 1° C or F 0.1° C or F 1° C or F Note: 1. Do not set the selector switch to position 9. This will cause error message “FFF” or “–––” to be displayed. 2. When changing scale ranges where the unit of measure changes 1° to 0.1° or vice versa, the set temperature also changes to reflect the unit of measure. For example, with a set temperature of 100°, a change from a scale range with 1° resolution to 0.1° makes the set temperature 10°; with a set temperature of 15°, a change in scale range resolution from 0.1° to 1° makes the set temperature 150°. Thermistor Input Type Thermistor input models are factory-set to switch position 0 for a temperature range of –50° to 50C°. Switch setting 0 1 2 3 4 5 6 7 8 9 Temp. range –50 to 50 0 to 100 50 to 100 to 150 to –50 to 100 0 to 200 100 to 200 to 300 to 150 200 300 300 400 600 Scale indication °C °F Unit of measure 1° C or F Note: 1. The temperature indication range for a setting scale of –50° to 50°C is –50° to 60°C. It is the full scale ±10% with the other set- ting scale ranges. 2. With a temperature range, such as 50° to 150°C, exceeds the factory-set range, the indication unit is automatically adjusted to the minimum value. The set temperature is displayed upon power application. 43 E5CS-X E5CS-X � SELECTING ALARM MODES Select one of the eight alarm modes by using the rotary DIP switch located next to the rotary DIP switch for temperature scale range selection. The following table shows alarm functions. The selector switch is factory-set to position 2, upper-limit alarm. Switch setting Mode Alarm output Notes 0, 9 No alarm OFF When the alarm mode selector switch is 0 or 9, neither the alarm value is displayed nor the AL indicator lights even when the return key is pressed. Alarm value setting range X may be 0 to full scale. 1 Upper- and lower-limit alarms If the alarm value is shifted outside the temperature If the alarm value is shifted outside the temperature scale range as a result of changing the scale range, it 2 Upper-limit alarm is automatically changed to the maximum value of the newly set scale range. 3 Lower-limit alarm 4 Upper- and lower-limit range alarm 5 Upper- and lower-limit alarms with standby sequence 6 Upper-limit alarm with standby sequence 7 Lower-limit alarm with standby sequence 8 Absolute-value alarm Alarm value setting range Y must be within the temperature scale range. Standby Sequence Alarm functions with standby sequence suppress nuisance When temperature falls below the set temperature alarms when the controller is first powered up. As shown in the temperature charts at right, the alarm output is suppressed until Upper-limit alarm the temperature exceeds the alarm band or alarm limit one time. When temperature rises from the set temperature Set temperature Upper-limit alarm Lower-limit alarm Set temperature Alarm output ON Lower-limit alarm OFF Alarm output ON OFF � SETTING KEY PROTECTION Protect against unauthorized changes in temperature values by ON disabling the operation of Up and Down keys. Set function ON selector DIP switch “P” to ON. To enable changes from the front panel, simultaneously press the hidden write protection key (lower left corner) with the Up and Down keys. If the internal PX16 2 3 4 5 protection switch is set to OFF, changes can be made simply by pressing the Up and Down keys. 44 E5CS-X E5CS-X � WHEN ALL FUNCTIONS HAVE BEEN SELECTED Neither the set alarm value is displayed nor the AL indicator To Set Temperature lights with the integral alarm mode setting switch set to 0 or 9. Be Press the return key until the SP indicator lights. Then set the sure to check the alarm mode setting switch, located inside the desired temperature value by using the Up and Down keys. housing, for proper setting. To Set Alarm Value In Case of Sensor Failure Press the return key until the AL indicator lights. Then set the The error message “FFF” or “–––” will appear on the main display desired alarm value in units of °F or °C. If the present tempera- if the temperature sensor short-circuits or breaks. ture exceeds the set alarm value, the alarm output will be issued. Precautions The E5CS-X temperature controller has self-diagnostic functions that display the following error messages to simplify troubleshooting. Message Cause Control output (1) Temperature has risen beyond temperature scale range OFF during heating (reverse) operation ��� (2) Thermistor has been short-circuited ON during cooling (normal) operation (1) Temperature has fallen below temperature scale range ON during heating (reverse) operation ��� (2) Thermistor has broken OFF during cooling (normal) operation (1) Failure has occurred in thermocouple or platinum RTD OFF ����(blinks)* (2) Temperature has risen much beyond scale range (1) Failure has occurred in platinum RTD OFF ��� (blinks)* (2) Polarities (positive and negative) of thermocouple are reversed (3) Temperature has fallen much below scale range (1) Memory failure (E11) display Both control outputs and the alarm output ��� or ���* (2) Analog-to-digital converter failure (E33) display are OFF Temperature controller must be repaired if recovery is not made by turning power off once and on again. Note: *Key operations are disabled. When the alarm outputs are used, an alarm output occurs when the “FFF” and “–––” messages appear in the display. These dis- plays indicate when the temperature has risen beyond or fallen below the temperature scale range. � SENSOR FAILURE INDICATION Condition Display Control output Thermocouple sensor Break in sensor OFF ����blinks Short-circuit Ambient temperature OFF Platinum RTD sensor Break in sensor OFF ����blinks OFF ��� blinks Disconnection of two or three wires OFF ����blinks Short-circuit OFF ��� blinks Thermistor sensor Break in sensor ON during heating (reverse) action ��� OFF during cooling (normal) action Short-circuit ON during heating (reverse) action ��� OFF during cooling (normal) action Note: The resistance of the platinum RTD is 100 Ω at 0°C and increases to 140 Ω at 100°C. 45 E5CS-X E5CS-X Installation � MOUNTING � CONNECTIONS All E5CS-X models conform to DIN 43700 standard. Recom- Connection Examples mended panel thickness is 1 to 4 mm (0.04 to 0.16 in). Use M3.5 solderless terminals with the temperature controller’s M3.5 self-rising pressure plate screws. Insert the temperature controller, back end first, into the panel cutout. Mount the adapter (Y92F-30) supplied with each unit by For solder-dipped leads, strip the lead wire 6 to 12 mm (0.24 to pushing it forward from the back of the temperature controller. 0.47 in) and carefully insert the wire tip. Do not tighten the termi- Push the adapter as close as possible to the front panel of the nal screw with excessive force. temperature controller to eliminate the gap between them. Then, secure the adapter with screws as shown. Removal 7.3 (0.29) 7.5 Loosen the screws on the adapter and push the hook open to (0.29) max. remove the adapter. Hook 19 (0.75) 6 to 12 (0.24 to 0.47) Screw Precautions Use lead wires having a small resistance for the platinum RTD � ENVIRONMENT type temperature controllers. Do not install the temperature controller in a location where there Sequence Circuit is a lot of dust or corrosive gases. Also avoid a location where Several seconds are required until the relay is turned ON after the temperature controller is subjected to heavy vibration, shock, the power has been applied to the temperature controller. Be splashes of water or oil, and high temperatures. sure to take this time lag into consideration when designing a Separate the temperature controller from equipment that sequence circuit which incorporates this temperature controller. generates strong, high-frequency electrical noise such as welding equipment. � RECALIBRATION Sensor Input Connections The lead wires connecting the platinum RTD to the temperature The E5CS-X temperature controller can be recalibrated by a controller must be separated from the power lines an the load factory-authorized repair service. Contact Omron for the location lines, wherever possible, to prevent them from being inducted by near you. electrical noise. Unauthorized recalibration of the controller will void the warranty Use the specified compensating conductors for the thermocouple and may lead to erratic input type temperature controllers. operation. ����������� � OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive 885 Milner Avenue Schaumburg, IL 60173 Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GCTC13 8/00 Specifications subject to change without notice. Printed in U.S.A.
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the E5CS-Q1KJX-F have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers








What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods