Omron 3G2C7-LK201-EV1 Interface Module - C20/C20K RS232 HOST LINK

Part Number

3G2C7-LK201-EV1

Price

Request Quote

Manufacturer

OMRON

Lead Time

Request Quote

Category

COMPONENTS

Datasheet

pdf file

Omron-3G2C7-LK201-EV1-ds1-224208583.pdf

1206 KiB

Extracted Text

FA Integrated Tool Package CX-One CX-Programmer Ver.8 CSM_CX-Programmer_Ver8_DS_E_1_1 Improve Productivity for SYSMAC PLCs from Ladder Program Development and Unit Setup to Debugging and Maintenance • Application software to create and debug programs for SYSMAC CS/CJ/CP/NSJ-series, C-series, and CVM1/C-series CPU Units. Features • Easily Achieve Position Control with Wading Through User Manuals. • Complete Support for Synchronous Operation between Units. • Easier Connection to PLCs. • Batch Backup/Restore with a Computer. • Comprehensive Programming Environment. • High Program Readability. • Time Required for Onsite Startup and Debugging Has Been Significantly Reduced. 1 CX-Programmer Ver.8 Ordering Information • International Standards • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. • Contact your OMRON representative for further details and applicable conditions for these standards. Support Software Specifications Product name Model Standards Number of Media licenses The CX-One is a package that integrates the Support Software CD CXONE-AL01C-V3 for OMRON PLCs and components. CX-One runs on the following OS. FA Integrated Tool 1 license *1 − Windows 2000 (Service Pack 3 or higher), XP, or Vista Package CX-One Ver.3.@ includes CX-Programmer Ver.8.@. CX-One Ver.3.@ DVD CXONE-AL01D-V3 For details, refer to the CX-One catalog (Cat. No. R134). *2 CX-Programmer can still be ordered individually in the following model numbers. 1 licenses CD WS02-CXPC1-V8 − CX-Programmer PLC programming software 3 licenses CD WS02-CXPC1-V8L03 − Ver.8.@ OS: Windows 2000 (Service Pack 3 or higher), XP, or Vista 10 licenses CD WS02-CXPC1-V8L10 − *1. Multi licenses are available for the CX-One (3, 10, 30, or 50 licenses). *2. When purchasing the DVD format, verify the computer model and DVD drive specifications before purchasing. Support Software (Micro PLC Edition) Specifications Product name Model Standards Number of Media licenses Micro PLC Edition PLC Support Software CX-Programmer OS: Windows 2000 (Service Pack 3 or higher), XP, or Vista 1 licence CD WS02-CXPC2-V8 − Ver.8.@ Applicable models: CP1L, CP1H, CPM@@, SRM1 Connecting Cables for CX-Programmer Applicable Cable Product name Model Standards computers length 0.1m CS1W-CN118 CE 2m CS1W-CN226 CE Programming Device Connecting Cables for Peripheral Port 6m CS1W-CN626 CE U, C, N, L, 3.3m CQM1-CIF02 CE 2m XW2Z-200P-V − IBM PC/AT or SYSMAC Host Link Cables (RS-232C cables compatible that are compatible with Programmable computers, D-Sub 9- Controllers) pin 5m XW2Z-500P-V − 2m XW2Z-200S-CV − 2m XW2Z-200S-V Programming Device Connecting Cables for RS-232C Port 5m XW2Z-500S-CV − 5m XW2Z-500S-V − USB-Serial Conversion Cable and PC driver IBM PC/AT or (on a CD-ROM disk) compatible computer 0.5m CS1W-CIF31 N Complies with USB Specification 1.1. (USB port) 2 CX-Programmer Ver.8 Applicable Cable Product name Model Standards computers length Programming Console Connecting Cable − 0.05m CS1W-CN114 CE Connecting Cable for peripheral and − 0.1m CPM2C-CN111 CE RS-232C port Peripheral interface Unit − 3.3m C200H-IP007 − Connecting Cable for peripheral port − 6m CV500-CIF01 − U, C, N, L, RS-232C Adapter −− CPM1-CIF01 CE Peripheral/RS-232C Adapter Unit −− CPM2C-CIF01-V1 U, C, CE RS-422/RS-232C Adapter Unit −− CPM2C-CIF11 U, C, CE Simple Communications Unit −| − CPM2C-CIF21 U, C, CE Note: For information on confirmations of the CX-Programmer, Connecting Cables, and PLCs, refer to Applicable Peripheral Devices in this datasheet. Product Configuration Setup disk : (CD) CD 1 piece in the case Guidance : A4 size, English/Japanese User license agreement/User registration card, English/Japanese 3 CX-Programmer Ver.8 Main Functions Category Function Create Ladder program on Ladder View Create Function Block Call on Ladder View Create Rung Comment on Ladder View Ladder Create Symbol Comments on Ladder View Create Attached Comment on Ladder View Create Ladder program on Mnemonic View Structured Text (ST) Create Program in Structured Text language Create Program in SFC SFC Create SFC Action program in Ladder or Structured Text language Create SFC Transition program in Ladder or Structured Text language Create Function Block Body in Ladder or Structured Text language Nesting Function Blocks (Up to 8 nesting levels) Function Block (FB) Nesting Tree View (FB Instance Viewer) Convert Ladder program to Function Block Cross Reference Report Cross Reference Pop-up Programming Program check Symbol programming Symbol check Delete Unused Symbols Address automatic allocation CX-Programmer configuration function (Option) Keyboard Mapping function Common Printing function Find/Replace Jump (Set Rung No./Program address/Set Rung with Commented Rung) Expansion advanced instructions (C series) UM area allocation (Set expansion fixed DM) (C200HS/E/G/X, CPM1/CPM1A, CPM2@) Rung wrap function of Ladder (Online) Edit IO comments function Section/Rung manage ROM Writer function Start The CX-Integrator (CS/CJ series) Import old support software data (LSS *1, SSS *2, CVSS *3, CPT *4, SYSWIN data) Import/Export reusable Symbol and Ladder Rung data file C500/C120/C**P backup Reuse of program PLC Backup Tool Operation (Backup/Compare/Restore) Memory Cassette Transfer function/Data Memory to Flash Memory Backup function (CP series) PLC Model conversion Communication with PLC directly Connection with PLC directly Auto Online to a PLC Auto Online - EtherNet/IP Node Online Communication with PLC on Network Ethernet Connection Using UDP/IP Ethernet Connection Using TCP/IP Connection with PLC Connection with PLC on Connecting Using EtherNet/IP Network Connecting Using Controller Link Network Service Board Connecting Using SYSMAC LINK Network Service Board Connecting Using SYSMAC NET Network Service Board Communication via modem Simulator Communication to Simulator Format Memory card Format EM file memory Transfer Program file, Data file, and Parameter file between CPU unit and File memory File memory operation Transfer Symbol Files and Comment Files between CX-Programmer and File Memory Delete file Transfer (Copy) files between storages *1. Ladder Support Software *2. SYSMAC Support Software *3. CV Support Software *4. SYSMAC-CPT 4 CX-Programmer Ver.8 Category Function Create, Edit, Check IO Table Verify/Compare IO Tables Delete IO Table Installing a CPS File (CS/CJ series) Display/Write unit production information, unit text (CS/CJ series) Display unit profile information (CS/CJ series) IO Table Set/Transfer/Compare Parameters for Special I/O Units and CPU Bus Units Save Parameters for SIOU Units and CPU Bus Units (CS/CJ series) Start Special Tool for SIOU Units and CPU Bus Units (CSCJ series) Display each rack's power consumption (CS/CJ series) Display rack width (CJ series) Printing function Display the Dip-switches status of the CPU Unit Transfer program (Program, Rung Comment, Attached Comment, IO Table, PLC Settings, Symbol Table, IO Memory, SIOU Unit Parameters) Transfer program Transfering in Task units Verify program (Program, Function Block Body, SFC action, SFC transition, IO Table, IO Memory, PLC setting) Monitoring Ladder View Monitoring Mnemonic View Monitoring Structured Text program Monitoring SFC program Monitoring program Monitoring SFC action, SFC transition, SFC subchart Displaying Flash-ROM back up status Monitoring Function Block Ladder View Monitoring Function Block ST View Set/Reset Change current value Force Set/Reset Change Timer/Counter setting values Differential monitor/Pause monitor Online edit Online editing of Function Block Display errors and error logs occurring Data trace, Time chart monitor Debug program Save result of data trace or time chart monitor Display cycle time/ task execution time Measure MARK instruction execution time (CV/CVM1 series) Read Protection Using Passwords (CS/CJ/CP series) Read Protection for Specific Tasks (CS/CJ/CP series) System or partial protection (CV/CVM1 series) Write Protection (CPM1/CPM1A, CPM2@) Password Protection of Function Bloks Read/Set clock Debugging by using a Simulator Simulation PLC-PT Integrated Simulation PLC Error Simulator Edit IO memory data Monitor IO memory data (PLC Memory window, Address monitor, Watch window, Ladder window, Mnemonic window) Edit/Monitor IO memory (Data memory) Verify/Transfer IO memory data Find contacts of Force set/reset Edit PLC settings Transfer PLC settings PLC settings Verify PLC settings Printing 5 CX-Programmer Ver.8 Category Function CX-Programmer project file (.CXP); A file containing the all user programs and parameter data created by CX-Programmer. (The .CXP file is a compressed version of the .CXT file.) CXT file (.CXT); A text-based format supported by CX-Programmer. The .CXT file format is used for file conversions. BAK file (.BAK); A backup copy of the project file. Program file (.OBJ); It indicates full program area files. Program index file (PROGRAMS.IDX); CX-Programmer section names, section comments, and program comments. Symbols file (SYMBOLS.SYM); CX-Programmer Global symbol tables, Local symbol tables, settings File extension for automatically allocated areas. Comment file (COMMENTS.CMT); CX-Programmer rung comments and comments. OPT file (.OPT); A file containing the preferences for the project. CXO file (.CXO); A file containing the settings made on the Options dialog and the Watch window. MAC file (.MAC); A file containing the keyboard mapping made on the Keyboard Mapping (Shortcut Keys) dialog. CX-Server file (.CDM); A file containing all of the information about the PLCs, which CX-Server can Appendix connect to and the addresses of interest in each PLC which may be accessed. A new CX-Server project can be created from the CX-Net Network Configuration tool. Ladder Section Window; It displays the Ladder program graphically. PLC program instructions can be entered as a graphical representation in Ladder form. Output Window; • [Compile]; The Compile tab displays the output produced from program compilation. Selecting an error highlights the source of the problem in the Ladder Diagram. The Compile tab also displays other information, for example, warnings and connection messages. • [Find Report]; The Find Report tab displays the output produced from a search of project files for a articular entry. • [Transfer]; The Transfer tab view displays the results of file or program loading. View Watch Window; It displays the value of the addresses of PLC memory during program execution. Mnemonics View; The Mnemonics view is a formatted editor for programming in mnemonic instructions. ST Editor Window; Displays the ST language can be input directly. SFC Editor Window; Displays an SFC chart or subchart. Symbol Table Window; Displays an editable list of symbol definitions - the names, addresses and comments. 6 CX-Programmer Ver.8 System Requirements Item Requirement Operating system (OS) *1 Microsoft Windows 2000 (Service Pack 3 or higher) or XP Microsoft Windows Vista *4 Japanese or English system IBM PC/AT or compatible with a Pentium II 333 MHz IBM PC/AT or compatible with a processor recommended Computer or faster processor (Pentium III 1 GHz or faster by Microsoft. (1 GHz or faster recommended) recommended.) Memory 256 MB minimum *2 512 MB min. required.1 GB min. recommended. Hard disk Approx. 2.5 GB or more available space is required to install the complete CX-One package. Display SVGA (800 × 600) or better high-resolution display with 256 colors min. Disk drive CD-ROM drive or DVD-ROM drive Communications ports RS-232C port, USB port, or Ethernet port *3 Other Internet access is required for online user registration, including a modem or other hardware connection method. *1. CX-One Operating System Precaution System requirements and hard disk space may vary with the system environment. *2. The amount of memory required varies with the Support Software used in CX-One for the following Support Software. Refer to user documentation for individual Support Software for details. CX-Programmer, CX-Designer, CX-Thermo, CX-Simulator, CX-Protocol, CX-Motion, CX-Drive, CX-Process Tool, and Faceplate Auto-Builder for NS *3. An RS-232C port is required to connect the Support Software in CX-One to a PLC. If the computer provides only a USB port, use a CS1W- CIF31 USB-to-RS-232C Conversion Cable. For connecting to the CP Series, however, an over-the-counter USB cable (type A-B) can be used. For the CX-Drive, the CS1W-CIF31 USB-to-RS-232C Conversion Cable cannot be used to connect a USB port on the computer to the 3G3MV. Use the recommended commercially available USB-serial conversion cable. For details, refer to the CX-Drive Programmable Controller Operation Manual (Cat. No. W453). *4. The following restrictions apply when CX-One is used with Microsoft Windows Vista. 1) Some Help files cannot be accessed. The Help files can be accessed if the Help program distributed by Microsoft for Windows Vista (WinHlp32.exe) is installed. Refer to the Microsoft homepage listed below or contact Microsoft for details on installing the file. (The download page is automatically displayed if the Help files are opened while the user is connected to the Internet.) http://support.microsoft.com/kb/917607/en-us 2) The following restrictions apply to some application operations. Application Restriction If a new Windows Vista font (e.g., Meiryo) is used in a project, the font size on labels may be bigger and protrude from the CX-Designer components if the project is transferred from CX-Designer running on a Windows XP or earlier OS to the NS/NSJ. When File Active Serial Port Driver is selected, a message stating that FinsGateway initialization failed may be displayed CX-Process and the serial driver may not be initialized. 7 CX-Programmer Ver.8 Applicable PLC Series CX-Programmer can be used with SYSMAC CS/CJ/CP/NSJ-series, C-series, and CVM1/C-series PLCs. Applicable CPU Units Series CPU Unit CS1H-CPU63/64/65/66/67 (-V1) CS1G-CPU42/43/44/45 (-V1) CS1H-CPU63H/64H/65H/66H/67H CS CS1G-CPU42H/43H/44H/45H CS1D-CPU65H/67H CS1D-CPU42S/44S/65S/67S CJ1G-CPU44/45 CJ1H-CPU65H/66H/67H/64H-R/65H-R/66H-R/67H-R CJ1G-CPU42H/43H/44H/45H CJ CJ1M-CPU11/12/13/21/22/23 CJ2H-CPU64-EIP/65-EIP/66-EIP/67-EIP/68-EIP CJ2H-CPU64/65/66/67/68 CP1H-XA40DR-A/XA40DT-D/XA40DT1-D/X40DR-A/X40DT-D/X40DT1-D/Y20DT-D CP1L-M40DR-A/M40DR-D/M40DT-D/M40DT1-D/M30DR-A/M30DR-D/M30DT-D/M30DT1-D/M60DR-A/M60DR-D CP /M60DT-D/M60DT1-D CP1L-L20DR-A/L20DR-D/L20DT-D/L20DT1-D/L14DR-A/L14DR-D/L14DT-D/L14DT1-D/L10DR-A/L10DR-D/L10DT-D /L10DT1-D NSJ5-@-G5D NSJ8-@-G5D NSJ10-@-G5D NSJ NSJ12-@-G5D NSJ5-@-M3D NSJ8-@-M3D C1000H C1000H-CPU01 C2000H C2000H-CPU01 Simplex system C200H C200H-CPU01/02/03/11/21/22/23/31 C200HX C200HX-CPU34/44/54/64 C200HG C200HG-CPU33/43/53/63 C200HE C200HE-CPU11/32/42 C200HX-Z C200HX-CPU34-Z/CPU44-Z/CPU54-Z/CPU64-Z/CPU65-Z/CPU85-Z C200HG-Z C200HG-CPU33-Z/CPU43-Z/CPU53-Z/CPU63-Z C200HE-Z C200HE-CPU11-Z/CPU32-Z/CPU42-Z C200HS C200HS-CPU01/03/21/23/31/33 CPM1/CPM1A CPM1 (A)-10CDR/20CDR/30CDR/40CDR (-V1) CPM2A-20CD/30CD/40CD/60CD CPM2@ CPM2C-10CD/10C1D/20CD/20C1D CPM2C-S100C/110C CPM2@-S@ CPM2C-S110C-DRT CQM1 CQM1-CPU11/21/41/42/43/44/45 CQM1H CQM1H-CPU11/21/51/61 CV1000 CV1000-CPU01 (-V1) CV2000 CV2000-CPU01 (-V1) CV500 CV500-CPU01 (-V1) CVM1 CVM1-CPU01/1 (-V1) CVM1-V2 CVM1-CPU01-V2/CPU11-V2/CPU21-V2 FQM1-CM001/CM002 Coordinator module FQM1 FQM1-MMA21/MMA22/MMP21/MMP22 Motion control module IDSC IDSC-C1DR-A/C1DT-A SRM1 SRM1-C01/C02 (-V1/-V2) 8 CX-Programmer Ver.8 Communication Method to Connect Applicable PLC and PC Via USB PC USB A plug (female) PLC USB B plug (male) Via RS-232C PC PC built-in RS-232C port CPU unit built-in peripheral port PLC CPU unit built-in RS-232C port Serial communication unil/board RS-232C port Via Ethernet PC Ethernet port, Ethernet Card PLC Ethernet unit, EtherNet/IP Unit Via Network Support Board Controller Link PC Controller Link board PLC Controller Link unit SYSMAC LINK PC SYSMAC LINK board PLC SYSMAC LINK unit SYSNET PC SYSNET board PLC SYSNET unit 9 CX-Programmer Ver.8 Applicable Peripheral Devices Connection Types for PLC and PC (CX-Programmer) PLC Port PC port (CX-Programmer) Connection Connecting Cables Types Conversion Cables (PLC) Conversion Cables (PC) Commercially available USB cable (A plug A USB B plug (male) − − USB A plug (female) connector (male) - B plug connector (female)) XW2Z-@@@ CS1W-CIF31 * B D-sub, 9-pin (female) − USB A plug (female) XW2Z-@@@P-V CS1W-CIF31 * C D-sub, 25-pin (female) − USB A plug (female) CQM1-CIF02 C Series peripheral − CS1W-CIF31 * CPM1-CIF01 D USB A plug (female) XW2Z-@@@S-V/S-CV CPM1, CPM1A, CPM2A, SRM1 CV500-CIF01 CS1W-CIF31 * E CV Series peripheral − USB A plug (female) CS1W-CN226/ CS1W-CN626 − CS1W-CIF31 * CS1W-CN118 XW2Z-@@@S-V/S-CV CS/CJ/CP/CQM1H F USB A plug (female) peripheral CS1W-CN114 CQM1-CIF02 * The CS1W-CIF31 is not required if the connector on the computer running the CX-Programmer has a D-sub, 9-pin male connector. Note: 1. PC (Personal Computer) : IBM PC/AT or compatible computer 2. A Host Link Unit (e.g., C200H-LK201-V1) or Peripheral Interface Unit (C200H-IP007) is required for some PLCs. Refer to the tables for individual PLCs for details. 10 CX-Programmer Ver.8 PLC Port PC port (CX-Programmer) Connection Connecting Cables Types Conversion Cables (PLC) Conversion Cables (PC) CS1W-CN226/ CS1W-CN626 − CPM2C-CN111 CS1W-CN114 CQM1-CIF02 CS1W-CN114 +CPM2C-CIF01-V1 CPM2C-CN111 CS1W-CIF31 * GCPM2C USB A plug (female) CS1W-CN118 CS1W-CN118 +CPM2C-CIF01-V1 XW2Z-@@@ CPM2C-CIF01-V1 CPM2C-CIF11 CPM2C-CIF21 * The CS1W-CIF31 is not required if the connector on the computer running the CX-Programmer has a D-sub, 9-pin male connector. Note: 1. PC (Personal Computer) : IBM PC/AT or compatible computer 2. A Host Link Unit (e.g., C200H-LK201-V1) or Peripheral Interface Unit (C200H-IP007) is required for some PLCs. Refer to the tables for individual PLCs for details. 11 CX-Programmer Ver.8 Connecting Cables for PLCs and PCs (CX-Programmer) Conversion Cables for USB-D-Sub 9-pin Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port RS-232C PC/AT USB A plug Depends on the Unit's − CS1W-CIF31 0.5m − D-sub, 9-pin (female) compatible connector (female) spcifications. Connecting Cables for CJ2 Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Commercially available USB cable USB B plug USB A plug USB or (A plug connector 5m maximum A connector (male) connector (female) Toolbu (USB port) PC/AT (male) - B plug CPU Unit compatible connector (female)) XW2Z-500S-CV 5m Built-in RS-232C port D-sub, 9-pin (male) Host Link B D-sub, 9-pin (female) XW2Z-200S-CV 2m Connecting Cables for CS1/CJ1 Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port CS1W-CN226 2m CS1W-CN626 6m Peripheral bus or Host CS1W-CN118 0.1m+2m Link +XW2Z-200S-CV CS1W-CN118 0.1m+5m Built-in peripheral +XW2Z-500S-CV F port CS1W-CN118 0.1m+2m +XW2Z-200S-V PC/AT Host Link CPU D-sub, 9-pin (male) compatible CS1W-CN118 0.1m+5m +XW2Z-500S-V Host Link with a baud rate CS1W-CN114 0.05m+3.3m of 19.2 kbps or less +CQM1-CIF02 XW2Z-200S-CV 2m Peripheral bus or Host Link XW2Z-500S-CV 5m Built-in RS-232C port B D-sub, 9-pin (female) XW2Z-200S-V 2m Host Link XW2Z-500S-V 5m Connecting Cables for CP1H/CP1L Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Commercially available USB cable USB B plug USB A plug USB (A plug connector 5m maximum A connector (male) connector (male) (male) - B plug connector (female)) PC/AT CPU compatible XW2Z-200S-CV 2m Peripheral bus or Host RS-232C port (D-sub Link XW2Z-500S-CV 5m 9-pin female) on D-sub, 9-pin (male) B Option Board XW2Z-200S-V 2m Host Link D-sub, 9-pin (female) XW2Z-500S-V 5m * An Option Board cannot be used with a CP1L CPU Unit with 10 Points. Connecting Cables for NSJ Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Commercially available USB cable USB B plug USB A plug USB (A plug connector 5m maximum A connector (male) connector (male) (male) - B plug connector (female)) PC/AT CPU compatible XW2Z-200S-CV 2m Peripheral bus or Host Link XW2Z-500S-CV 5m Built-in RS-232C port D-sub, 9-pin (male) B D-sub, 9-pin (female) XW2Z-200S-V 2m Host Link XW2Z-500S-V 5m 12 CX-Programmer Ver.8 Connecting Cables for C200HS Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Built-in peripheral Peripheral bus or Host CQM1-CIF02 3.3m D port Link XW2Z-200S-CV 2m Built-in RS-232C port CPU Unit XW2Z-500S-CV 5m D-sub, 9-pin (female) PC/AT B (CPU 21/23/31/33 D-sub, 9-pin (male) XW2Z-200S-V 2m compatible only) Host Link XW2Z-500S-V 5m Built-in RS-232C port XW2Z-200P-V 2m Host Link Unit C200H- D-sub, 25-pin C LK201-V1 XW2Z-500P-V 5m (female) Connecting Cables for C200HX/HG/HE Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Built-in peripheral Peripheral bus * or Host CQM1-CIF02 3.3m D port Link XW2Z-200S-CV 2m CPU XW2Z-500S-CV 5m Built-in RS-232C port PC/AT B D-sub, 9-pin (female) D-sub, 9-pin (male) XW2Z-200S-V 2m compatible Host Link XW2Z-500S-V 5m Built-in RS-232C port XW2Z-200P-V * 2m Host Link Unit D-sub, 25-pin C C200H-LK201-V1 XW2Z-500P-V * 5m (female) * These Cables cannot be used for Programming Devices, such as the CX-Programmer, for the C200H-LK201-V1 Host Link Unit on a C200HX/ HG/HE-Z PLC. Connecting Cables for CQM1H Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port CS1W-CN226 2m CS1W-CN626 6m CS1W-CN114 0.05m+3.3m +CQM1-CIF02 CS1W-CN118 0.1m+2m Built-in peripheral Peripheral bus or Host +XW2Z-200S-CV F port Link CS1W-CN118 0.1m+5m +XW2Z-500S-CV PC/AT CPU D-sub, 9-pin (male) compatible CS1W-CN118 0.1m+2m +XW2Z-200S-V CS1W-CN118 0.1m+5m +XW2Z-500S-V XW2Z-200S-CV 2m XW2Z-500S-CV 5m Built-in RS-232C port Host Link B D-sub, 9-pin (female) XW2Z-200S-V 2m XW2Z-500S-V 5m Connecting Cables for CQM1 Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Built-in peripheral Peripheral bus or Host CQM1-CIF02 3.3m D port Link XW2Z-200S-CV 2m PC/AT Built-in RS-232C port CPU D-sub, 9-pin (male) compatible XW2Z-500S-CV 5m D-sub, 9-pin (female) Host Link B (CPU42/43/44/63/64/ XW2Z-200S-V 2m 65/85 only) XW2Z-500S-V 5m 13 CX-Programmer Ver.8 Connecting Cables for CPM1, CPM1A and CPM2A Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port CPM1-CIF01 2m +XW2Z-200S-CV Peripheral bus or Host Link CPM1-CIF01 5m +XW2Z-500S-CV Built-in peripheral PC/AT CPU Unit D-sub, 9-pin (male) D port compatible CPM1-CIF01 2m +XW2Z-200S-V Host Link CPM1-CIF01 5m +XW2Z-500S-V * CPM2A CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) do not support Toolbus connections. They do support Host Link connections. Connecting Cables for SRM1 Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port CPM1-CIF01 2m +XW2Z-200S-CV Peripheral bus or Host Link CPM1-CIF01 5m +XW2Z-500S-CV Built-in peripheral D port CPM1-CIF01 2m +XW2Z-200S-V PC/AT CPU Unit D-sub, 9-pin (male) CPM1-CIF01 compatible 5m +XW2Z-500S-V Host Link XW2Z-200S-CV 2m Built-in RS-232C port XW2Z-500S-CV 5m D-sub, 9-pin (female) B XW2Z-200S-V 2m (SRM1-C01 only) XW2Z-500S-V 5m 14 CX-Programmer Ver.8 Connecting Cables for CPM2C Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port CS1W-CN226 *22m CS1W-CN626 *26m CS1W-CN114 0.05m+3.3m +CQM1-CIF02 Communications port Peripheral bus *1 or Host CPM2C-CIF01-V1 Adapter+ (as a peripheral port) Link +CS1W-CN114 0.05m + 3.3m +CQM1-CIF02 CPM2C-CN111 (Peripheral port) 0.1m+3.3m +CQM1-CIF02 CS1W-CN118 0.1m+2m +XW2Z-200S-CV CS1W-CN118 0.1m+5m +XW2Z-500S-CV CPM2C-CN111 (RS-232C port) 0.1m+2m +XW2Z-200S-CV CPM2C-CN111 (RS-232C port) 0.1m+5m +XW2Z-500S-CV CPM2C-CIF01-V1 Adapter+2m +XW2Z-200S-CV CPM2C-CIF01-V1 Adapter+5m +XW2Z-500S-CV CPM2C-CIF01-V1 Adapter +CS1W-CN118 0.1m+2m +XW2Z-200S-CV CPM2C-CIF01-V1 Adapter PC/AT +CS1W-CN118 CPU D-sub, 9-pin (male) 0.1m+5m G compatible +XW2Z-500S-CV CS1W-CN118 0.1m+2m +XW2Z-200S-V CS1W-CN118 0.1m+5m +XW2Z-500S-V Communications port Host Link (as an RS-232C port) CS1W-CN111 (RS-232C port) 0.1m+2m +XW2Z-200S-V CS1W-CN111 (RS-232C port) 0.1m+5m +XW2Z-500S-V CPM2C-CIF01-V1 Adapter+2m +XW2Z-200S-V CPM2C-CIF01-V1 Adapter+5m +XW2Z-500S-V CPM2C-CIF01-V1 Adapter+ +CS1W-CN118 0.1m+2m +XW2Z-200S-V CPM2C-CIF01-V1 Adapter+ +CS1W-CN118 0.1m+5m +XW2Z-500S-V CPM2C-CIF11 Adapter+2m +XW2Z-200S-V CPM2C-CIF11 Adapter+5m +XW2Z-500S-V CPM2C-CIF21 Adapter+2m +XW2Z-200S-V CPM2C-CIF21 Adapter+5m +XW2Z-500S-V *1. CPM2C CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) and that were manufactured in 1999 do not support Toolbus connections. They do support Host Link connections. *2. Only Host Link (SYSMAC WAY) connections are possible. Toolbus cannot be used. Note: Refer to the CPM2C Operation Manual (Cat. No. W340) for details. 15 CX-Programmer Ver.8 Connecting Cables for C1000H, C2000H, C200H Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Built-in peripheral C200H-IP007 CPU Unit 3.3m D port +CQM1-CIF02 Host Link Unit C1000H, C2000H: XW2Z-200P-V 2m C500-LK203 C500-LK201-V1 PC/AT D-sub, 9-pin (male) Host Link (3G2A5-LK201-V1) Built-in RS-232C port compatible C120-LK201-V1 D-sub, 25-pin C (3G2A6-LK201-EV1) (female) C200H: XW2Z-500P-V 5m C200H-LK201-V1 C120-LK201-V1 (3G2A6-LK201-EV1) Connecting Cables for CVM1/CV Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Built-in peripheral CV500-CIF01 6m E port CPU Unit XW2Z-200S-V * 2m Built-in RS-232C port B D-sub, 9-pin (female) XW2Z-500S-V * 5m Host Link Unit XW2Z-200P-V 2m CV500-LK201 Built-in RS-232C port PC/AT (for full duplex D-sub, 25-pin C D-sub, 9-pin (male) Host Link compatible communication on (female) XW2Z-500P-V 5m port 1) Host Link Unit XW2Z-200S-V 2m CV500-LK201 Built-in RS-232C port (for full duplex B D-sub, 9-pin (female) communication on XW2Z-500S-V 5m port 2) * The XW2Z-200S-CV and XW2Z-500S-CV cannot be used. Connecting Cables for C500 Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Built-in peripheral C200H-IP007 CPU Unit *1 3.3m D port +CQM1-CIF02 Host Link Unit *2 XW2Z-200P-V 2m PC/AT C500-LK203 D-sub, 9-pin (male) Host Link Built-in RS-232C port compatible C500-LK201-V1 D-sub, 25-pin C (3G2A5-LK201-EV1) (female) XW2Z-500P-V 5m C120-LK201-V1 (3G2A6-LK201-EV1) *1. Production of the CPU Units was discontinued in March 2004. *2. Production of the C500-LK203, C500-LK201-V1 (3G2A5-LK201-EV1), and C120-LK201-V1 (3G2A6-LK201-EV1) was discontinued in March 2006. (There is no recommended substitute product.) Connecting Cables for C120 Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Built-in peripheral C200H-IP007 CPU Unit *1 3.3m D port +CQM1-CIF02 PC/AT D-sub, 9-pin (male) Host Link Host Link Unit *2 Built-in RS-232C port XW2Z-200P-V 2m compatible C120-LK201-V1 D-sub, 25-pin C XW2Z-500P-V 5m (3G2A6-LK201-EV1) (female) *1. Production of the CPU Units was discontinued in March 2003. *2. Production of the C120-LK201-V1 was discontinued in March 2006. (There is no recommended substitute product.) *1 *2 Connecting Cables for C20P/C28P/C40P/C60P , C20K/C28K/C40K/C60K Unit Computer Network Type (Serial Connection Model Cable length Communications Mode) Types Unit port PC port Host Link Unit *3 *4 Built-in RS-232C port XW2Z-200P-V 2m PC/AT C20-LK201-V1 D-sub, 25-pin D-sub, 9-pin (male) Host Link C compatible XW2Z-500P-V 5m (3G2C7-LK201-EV1) (female) *1. Production of the C20P, C28P, C40P, and C60P CPU Units was discontinued in March 2002. *2. Production of the C20K, C28K, C40K, and C60K CPU Units was discontinued in March 2002. *3. For connection to C@@P PLCs, a Host Link Unit is also required in addition to a Connecting Cable. *4. Production of the C20-LK201-V1 (3G2C7-LK201-EV1) was discontinued in March 2006. (There is no recommended substitute product.) 16 CX-Programmer Ver.8 Related Manuals Cat.No. Model Manual name Contents CX-Programmer Ver.8.@ Provides information on how to use the CX-Programmer for all functionality except for W446 WS02-CXPC@-V8 Operation Manual function blocks. CX-Programmer Ver. 8.@ Describes the function block functions and structured text programming functions that can W447 WS02-CXPC@-V8 Operation Manual Function be used with the CX-Programmer version 8.@. For details on other CX-Programmer Blocks/Structured Texts functions, refer to the CX-Programmer Ver. 8.@ Operation Manual (Cat. No.W446). CX-Programmer Explains how to use the SFC programming functions. For explanations of other shared W469 WS02-CXPC@-V8 Operation Manual: SFC CX-Programmer functions, refer to the CX-Programmer Operation Manual (W446). CXONE-AL@@C-V3/ W463 CX-One Setup Manual Installation and overview of CX-One FA Integrated Tool Package. AL@@D-V3 CXONE-AL@@C-V3/ CX-Integrator W445 Describes the operating procedures for the CX-Integrator. AL@@D-V3 Operation Manual 17 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: · Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. · Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. · Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.5 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron :   3G2C7-LK201-EV1

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 3G2C7-LK201-EV1 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Omron 3G2A5-II101 - I/O Control Module

product

Omron 3G2A5-PS221-E power supply - POWER SUPPLY MODULE C500 24VDC FOR CPU

product

OMRON-3G2A6-LK201-EV1-Adapter - HOST LINK ADAPTER MODULE

product

Omron 3G2C7-CPU34E CPU module - CPU MODULE WITH I/O AND BASE CR-69

product

Omron 3G2S6-CPU11 Controller - Sysmac S6 Programmable Controller 24V AC/DC

product

Omron 3G2S6-CPU17 programmer controller 24V AC/DC