Elite.Parts chervon right Manufacturers chervon right N chervon right NOTIFIER CO chervon right FSD751RPL
About product Datasheet FAQ

NOTIFIER CO FSD751RPL

Description

DETECTOR

Part Number

FSD751RPL

Price

Request Quote

Manufacturer

NOTIFIER CO

Lead Time

Request Quote

Category

PRODUCTS - F

Datasheet

pdf file

Notifier-FSD-751PL-ds1-612553772.pdf

956 KiB

Extracted Text

DN-6955:A • H-215 FSD-751PL(A), FSD-751RPL(A) Intelligent Low-Flow Photoelectric Duct Smoke Detectors with FlashScan® Intelligent Addressable Devices General NOTIFIER FSD-751PL(A) and FSD-751RPL(A) Intelligent Pho- toelectric Smoke Duct Detectors provide low-flow technology that enables duct smoke detection throughout a broad range of airflow environments in HVAC applications. The low-flow tech- nology can detect smoke at air speed velocities of 100 feet per minute (0.5 m/sec) or greater, while continuing the same reliable performance to 4,000 feet per minute (20.32 m/sec). The intelli- gent low-flow duct detectors sample air currents passing 52398ph1.jpg through a duct and gives dependable performance for shutdown of fans, blowers, and air conditioning systems, preventing the spread of toxic smoke an fire gases through the protected area. FSD-751PL FSD-751PL(A) and FSD-751RPL(A) are compatible with all NOTIFIER addressable panels. FSD-751PL(A) and FSD- 751RPL(A) provide a remote alarm output for use with auxiliary devices, such as the RA400Z(A) remote LED annunciator, as well as remote test capability with the RTS451(A) or RTS451KEY(A) Remote Test Stations. Traditional panels support addresses of 0 – 99. The Flash- Scan® protocol supports addresses of 0 – 159. The patented FlashScan communication protocol was developed by NOTI- FIER Engineering, it greatly enhances the speed of communica- 52398ph2.jpg tion between analog intelligent devices and the Notifier control panel. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the FSD-751RPL panel stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of 3242ra4z.jpg 3242rts4.jpg 3242key.jpg earlier designs. Applications Duct smoke detectors have specific limitations, they are: • NOT a substitute for open area smoke detectors. • NOT a substitute for early warning detection. • NOT a replacement for a building’s regular fire detection sys- tem. Please call NOTIFIER for a copy of System Sensor’s application guide, Proper Use of Smoke Detectors in Duct Applications, (A05-1004-00). RA400Z RTS451 RTS451KEY duct smoke detector terminals accommodate wire sizes up to 12 Features AWG (3.31 mm²). Flexible conduit is recommended for the last • Air velocity rating from 100 to 4,000 feet per minute (0.5 to foot (30.48 cm) of conduit; solid conduit connections may be 20.32 m/sec). used if desired. • Patented telescopic sampling tube. Smoke detectors and alarm system control panels have specifi- • Easily accessible code wheels for addressing detector. cations for Signaling Line Circuit (SLC) wiring. Consult the con- trol panel specifications for wiring requirements before wiring • Outside mounting tabs. the detector loop. The FSD-751PL(A) and FSD-751RPL(A) • Mounts to round or rectangular ducts from 1’ to 12’ (0.3 to 3.7 detectors are designed for ease of wiring; their housing provides meters) wide. a terminal strip with clamping plates. • Transparent cover for convenient visual inspection. LED Features: If programmed with the system control panel, two LEDs on each duct smoke detector light to provide local vis- Installation ible indication. Refer to installation manuals for control panel and duct detector Programming specifications/requirements for intelligent for detailed information or to install equipment. Installation man- system control panels: The number of devices that can have uals for detectors: I561978-003R for FSD-751PL(A), 156-1979- their LEDs programmed to illuminate is limited by the features of 004R for FSD-751RPL(A). the panel and the individual devices. The actual number of devices is determined by the control panel and its ability to sup- Wiring: For signal wiring (the wiring between detectors or from ply LED current. Refer to the control panel installation manual detectors to auxiliary devices), it is recommended that single for details. conductor wire be no smaller than 18 AWG (0.821 mm²). The DN-6955:A • 12/29/06 — Page 1 of 4 Wiring Diagrams for FSD-751PL(A) On to other Detectors on the Loop. 6821wir1.wmf FSD-751PL(A) Duct Smoke Detector using a UL or ULC Listed control panel. FSD-751PL(A) Duct Smoke Detector with an optional Detector RA400Z Terminals RA400Z(A). 6821wir2.wmf FSD-751PL(A) Duct Smoke Detector with RTS451(A)/ 6821wir3.wmf RTS451KEY(A). Detector COMMON TEST NOTE: For RTS451(A), Terminal 3 is not Terminals used. RTS451(A) does not have a Terminal 45 6 6. For RTS451KEY(A), Terminals 3 and 6 Field-Installed are not used. JUMPER 12 3 LED RESET RTS451/RTS451KEY Inlet Tube Selection Outside Duct Width Inlet Tube* Up to 2 feet (0.6096 m) ST-1.5(A) 2 to 4 feet (0.6096 to 1.2192 m) ST-3(A) 4 to 8 feet (1.2192 to 2.4384 m) ST-5(A) 8 to 12 feet (2.4384 to 3.6576 m) ST-10(A) *Inlet tube is required and must be purchased separately. Order One inlet tube for each duct smoke detector ordered. Page 2 of 4 — DN-6955:A • 12/29/06 TEST RA400Z RA400Z RTS451KEY COMMON COMMON COM (+) COM (–) Wiring Diagrams for FSD-751RPL(A) FSD-751RPL(A) Duct Smoke Detector using a UL-Listed control panel: NOTE: 1) Jumper J1 shunt must be installed for 2-W applications. J1 shunt must be removed for power PCB supervision. Note that removal of shunt without adding external power will prevent communications to the panel over the SLC. 2) External power of 24 V AC/DC or 120/220 VAC must be connected in order to power all remote horn or strobe accessories. FSD-751RPL(A) Duct Smoke Detector FSD-751RPL(A) Duct with an optional RA400Z(A): Smoke Detector with RTS451(A)/RTS451KEY(A): FSD-751RPL(A) Duct Smoke Detector with an optional PA400: 7006wir4.wmf DN-6955:A • 12/29/06 — Page 3 of 4 7006wir1.wmf 7006wir2.wmf 7006wir3.wmf Standby current: 300 µA @ 24 VDC (one communication Product Line Information every 5 seconds with LED blink enabled). NOTE: “A” model suffix is for Canadian models. Operating temperature range: 32° to 131°F (0° to 55°C). FSD-751PL: Addressable low-flow duct detector housing with Operating humidity range: 10% to 93% relative humidity (non- photoelectric smoke detector. condensing). FSD-751PLA: Same as above with ULC listing. Storage temperature range: –22°F to +158°F (–30°C to +70°C). FSD-751RPL: Addressable low-flow duct detector housing with Duct air velocity: 100 to 4,000 feet/min (0.5 to 20.32 m/s). photoelectric smoke detector with DPDT relay. Shipping weight: 3.90 lbs. (1.8 kg). FSD-751RPLA: Same as above with ULC listing. Dimensions: 14.75" (37 cm) length x 5.50" (14 cm) width x A5053FS: Replacement photoelectric sensor board. 2.75" (7 cm) deep. A5067: Replacement power board (without relay). FSD-751RPL(A) CONTACT RATINGS A5060: Replacement power board (with relay). Alarm auxiliary contacts (DPDT): 10 A @ 30 VDC; 10 A @ ST-1.5(A): Metal sampling tube, duct widths 1' to 2' (see Inlet 277 VAC (0.75 power factor); 240 VA @ 249 VAC (0.4 power Tube Selection table on page 2 for metric lengths). factor); 1/8 HP @ 120 VAC; 1/4 HP @ 240 VAC. ST-3(A): Metal sampling tube, duct widths 2' to 4'. Minimum switching current for auxiliary contact must be ST-5(A): Metal sampling tube, duct widths 4' to 8'. 100 mA DC minimum @ 5 VDC. ST-10(A): Metal sampling tube, duct widths 8' to 12'. Supervisory contact (SPST): 2.0 A @ 30 VDC (resistive). RA400Z(A): Remote annunciator alarm LED. FSD-751RPL(A) accessory current loads @ 24 VDC: PA400: RTS451(A): Remote test station. Mounts in single-gang box. refer to PA400 data sheet DN-2405. RA400Z(A): 0 mA standby, Includes red alarm LED and magnet test switch. 12 mA maximum in alarm. RTS451(A) and RTS451KEY(A): 0 RTS451KEY(A): Key-activated remote test station. mA standby, 10 mA maximum in alarm. F36-09-11: Replacement filters. M02-04-00: Test magnet. FSD-751RPL(A) CURRENT REQUIREMENTS (USING M02-09-00: Test magnet with telescoping handle. NO ACCESSORIES) S08-39-01: Replacement photo insect screen. 20 – 30 VDC power supply voltage: 26 mA maximum standby P48-61-00: Replacement end cap for plastic sampling tube. current; 87 mA maximum alarm current; 3 to 10 second alarm P48-21-00: Replacement end cap for metal sampling tube. response time; 2 second power-up time. T80-71-00: Replacement plastic sampling tube. 24 VAC, 50/60 Hz power supply voltage: 65 mA RMS maxi- mum standby current; 182 mA RMS maximum alarm current; 3 Specifications to 10 second alarm response time; 2 second power-up time. 120 VAC, 50/60 Hz power supply voltage: 44 mA RMS maxi- FOR FSD-751PL(A) mum standby current; 52 mA RMS maximum alarm current; 3 to 10 second alarm response time; 2 second power-up time. Operating voltage range: 15 to 30 VDC. Standby current: 300 µA @ 24 VDC (one communication 220/240 VAC, 50/60 Hz power supply voltage: 25 mA RMS every 5 seconds with LED blink enabled). maximum standby current; 30 mA RMS maximum alarm current; 3 to 10 second alarm response time; 2 second power-up time. Operating temperature range: 32° to 131°F (0° to 55°C). Operating humidity range: 10% to 93% relative humidity (non- condensing). Agency Listings and Approvals Storage temperature range: –22°F to +158°F (–30°C to +70°C). The listings and approvals below apply to FSD-751PL(A) and Duct air velocity: 100 to 4,000 feet/min (0.5 to 20.32 m/s). FSD-751RPL(A) Intelligent Low-Flow Photoelectric Smoke Duct Shipping weight: 3.35 lbs. (1.5 kg). Detectors. In some cases, certain modules may not be listed by Dimensions: 14.75" (37 cm) length x 5.50" (14 cm) width x certain approval agencies, or listing may be in process. Consult 2.75" (7 cm) deep. factory for latest listing status. FSD-751PL(A) accessory current loads @ 24 VDC: • UL Listed: file S1115 (FSD-751PL, FSD-751RPL). RA400Z(A): 0 mA standby, 10 mA maximum in alarm. • ULC Listed: file S115 (FSD-751PLA, FSD-751RPLA). RTS451(A) and RTS451KEY(A): 0 mA standby, 7.5 mA maxi- • CSFM approved: file 3240-0028:205. mum in alarm. • FM approved. FOR FSD-751RPL(A) • MEA approved: file 384-02-E. • Maryland State Fire Marshal approved: Permit #2127. Operating voltage range: 20 to 30 VDC, 24 VAC/VDC, 120/ 240 VAC auxiliary power (requires a separate auxiliary source). FlashScan®, NOTIFIER® and System Sensor® are registered trademarks of Honeywell International Inc. ©2006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4 — DN-6955:A • 12/29/06

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the FSD751RPL have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

NOTIFIER CO F110BP Retrofit replacement flange for older style bases.

NOTIFIER CO F210 Replacement flange for B210LP(A) base

product

Notifier Co FCPS-24S8 Power Supply with 6/8Amp and 24VDC

product

Notifier FSD-751PL PHOTOELECTRIC INTELLIGENT DUCT SMOKE DETECTOR

product

Notifier Co FSP851 Intelligent Plug-In Photoelectric Smoke Detector with FlashScan

product

Notifier Co FSP-851T Smoke Detector Head