MEAN WELL LPF-40-54
Specifications
AC CURRENT (Typ.)
0.6A/115VAC 0.3A/230VAC 0.25A/277VAC
CONSTANT CURRENT REGION
32.4-54V
DC VOLTAGE
54V
DIMENSION
162.5*43*32mm(L*W*H)
EFFICIENCY (Typ.)
90%
FREQUENCY RANGE
47-63mHz
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
INRUSH CURRENT (Typ.)
Cold Start 75A/230VAC
LINE REGULATION
0.5%
LOAD REGULATION
0.5%
OVER LOAD
95-108%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
59 ~ 66V
Protection Type: Shut down and latch off o/p voltage, re-power on to recover
RATED CURRENT
0.76A
RATED POWER
41.04W
RIPPLE & NOISE (max.)
350mVp-p
SETUP, RISE TIME
1000ms,80ms/115VAC at full load 1200ms,80ms/230VAC
VOLTAGE RANGE
90-305VAC 127-431VDC
VOLTAGE TOLERANCE
4.0%
Features
- 100% full load burn-in test
- Built-in active PFC function
- Class 2 power unit
- Class II power unit, no FG
- Cooling by free air convection
- Fully Encapsulated IP67 design
- Fully isolated plastic case
- High Efficiency up to 89%
- Protections: Short circuit / Over temperature/ Over Voltage
- Suitable for dry / damp locations
- Suitable for dry or damp locations
- Suitable for LED lighting and moving sign applications
- Universal AC input / Full range (up to 305VAC)
Datasheet
Extracted Text
40W Single Output Switching Power Supply LPF- 40 seri es Features : Universal AC input / Full range (up to 305VAC) Built-in active PFC function High efficiency up to 89% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Fully isolated plastic case Fully encapsulated with IP67 level (Note.6) Class power unit, no FG Class 2 power unit Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting Suitable for dry / damp / wet locations 3 years warranty 110 F M M SELV ( for 48V,54V only) ( except for 48V,54V ) I P 6 7 SPECIFICATION MODEL LPF-40-12 LPF-40-15 LPF-40-20 LPF-40-24 LPF-40-30 LPF-40-36 LPF-40-42 LPF-40-48 LPF-40-54 DC VOLTAGE 12V 15V 20V 24V 30V 36V 42V 48V 54V 21.6 ~ 36V 25.2 ~ 42V CONSTANT CURRENT REGION Note.4 7.2 ~12V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V 28.8 ~ 48V 32.4 ~ 54V RATED CURRENT 3.34A 2.67A 2A 1.67A 1.34A 1.12A 0.96A 0.84A 0.76A RATED POWER 40.08W 40.08W 40W 40.08W 40.2W 40.32W 40.32W 40.32W 41.04W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 250mVp-p 250mVp-p 350mVp-p OUTPUT VOLTAGE TOLERANCE Note.3 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 0.5% 0.5% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 2.0% 1.5% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME Note.7 1000ms, 80ms / 115VAC at full load 1200ms, 80ms / 230VAC HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) INPUT EFFICIENCY (Typ.) 84% 85% 86% 87% 88% 88% 88.5% 90% 90% AC CURRENT (Typ.) 0.6A / 115VAC 0.3A / 230VAC 0.25A / 277VAC INRUSH CURRENT (Typ.) COLD START 75A/230VAC LEAKAGE CURRENT <0.75mA / 240VAC 95 ~ 108% OVER CURRENT Note.4 Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed. 15 ~ 17V 17.5 ~ 21V 23 ~ 27V 28 ~ 35V 34 ~ 40V 41 ~ 49V 46 ~ 54V 54 ~ 63V 59 ~ 66V PROTECTION OVER VOLTAGE Protection type : Shut down and latch off o/p voltage, re-power on to recover 90 10 (RTH2) OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover -40 ~ +70 (Refer to "Derating Curve") WORKING TEMP. 20 ~ 95% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +80 , 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP67, J61347-1, J61347-2-13 SAFETY STANDARDS Note.6 approved ; design refer to UL60950-1, TUV EN60950-1 SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC EMC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMC EMISSION Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A EMC IMMUNITY MTBF 438.8Khrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 162.5*43*32mm (L*W*H) 0.44Kg; 32pcs/15.08Kg/0.93CUFT PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. File Name:LPF-40-SPEC 2012-04-17 40W Single Output Switching Power Supply LPF-40 series Mechanical Specification Case No. LPF-60B Unit:mm 162.5 3.5 300 20 300 20 AC/N(Blue) T case AC/L(Brown) 60 +V(Red) SJTW 18AWG 2C -V(Black) SVT 18AWG 2C 3.5 T case: Max. Case Temperature. Block Diagram Fosc : 100KHz EMI FILTER RECTIFIERS POWER PFC +V I/P & & SWITCHING CIRCUIT -V RECTIFIERS FILTER O.L.P. DETECTION O.L.P. PWM & PFC CIRCUIT CONTROL O.V.P. D De er ra at tiin ng C g Cu ur rv ve e Static Characteristics 100 100 90 80 80 70 60 60 40 50 20 40 -40 -30 0 0 15 30 40 50 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 1 17 75 5 180 200 230 305 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:LPF-40-SPEC 2012-04-17 3.6 3.6 L L LO O OA A AD ( D ( D (% % %) ) ) 3.5 43 L LO OA AD ( D (% %) ) 13 3.5 32 40W Single Output Switching Power Supply LPF-40 series Power Factor Characteristic Constant Current Mode 1 0 . 9 9 0 . 9 8 0 . 9 7 0 . 9 6 0 . 9 5 0 . 9 4 0 . 9 3 2 7 7 V A C 0 . 9 2 2 3 0 V A C 0 . 9 1 1 1 5 V A C 0 . 9 0 . 8 9 0 . 8 8 0 . 8 7 0 . 8 6 0 . 8 5 0 . 8 4 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % (40W) LOAD EFFICIENCY vs LOAD (48V Model) LPF-40 series possess superior working efficiency that up to 90% can be reached in field applications. 9 3 9 2 9 1 9 0 8 9 8 8 8 7 8 6 8 5 8 4 8 3 8 2 2 7 7 V AC 8 1 8 0 2 3 0 V AC 7 9 7 8 1 1 5 V AC 7 7 7 6 7 5 7 4 7 3 7 2 7 1 7 0 1 0 % 2 0 % 3 0 % 4 0 % 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % LOAD DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B). (B) 100 Constant Current area (A) Constant Voltage area 60 (max.) (C) Hiccup Protection 50 95 Io (%) Typical LED power supply I-V curve File Name:LPF-40-SPEC 2012-04-17 PF EFFICIENCY (%) Vo(%)
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the LPF-40-54 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods