Specifications

Dimensions A

in.: 3 3/8, mm: 86

Dimensions B

in.: 3 7/8, mm: 98

Injector outlet

¹/8" O.D. Tube

Manifold inlet

¹/8" NPTF (F)

Number of outlets

4

Operating Pressure Max

3500 psig, 241 bar

Operating Pressure Min

1200 psig, 83 bar

Operating Pressure Typical

1500 psig, 103 bar

Operating Pressure Vent

200 psig, 14 bar

Output Max

.003 cu. in. .049 cc

Output Min

.001 cu. in. .016 cc

Series

SL-33

Features

Datasheet

pdf file

LINCOLN-SL-33-datasheet-17256334401.pdf

2154 KiB

Extracted Text

®®® CENTR CENT CENTR RO-M O-MA O-MA AT TIC TIC IC A AU AUT UT TO OM OM MA A ATED TED TED LU L LUBRI UBRI BRIC C CA A ATION TION TION S S SY Y YS S STEMS TEMS TEMS "I install Lincoln Centro-Matic systems with confidence because I know they're going to prolong the life of my customer's critical machinery." Les Maness, Installation Foreman, Lincoln Distributor People, Capabilities and Systems to Save Money and Increase Productivity We’re the largest and most successful company in our field Industrial Solutions because we continually satisfy our customers with the world’s best lubrication and pumping systems. For almost 90 years, companies have relied on our technical and quality leadership, our world-class manufacturing and customer service, and our vast network of distributors and support facilities. Worldwide Support Lincoln develops new products and systems at research and development facilities in the U.S., Germany and India that provide global and regional application solutions. We have solutions for large processing plants, automotive manufacturing, pulp and paper Quality mills, and food and beverage Manufacturing facilities. Virtually every industrial professional involved in operations and maintenance can benefit from Lincoln systems. On the road or in the field, Lincoln protects heavy equipment used in mining, construction, agriculture and over-the-road trucking. The world’s leading manufacturers offer our systems as standard equipment or factory options. Customer Service Lincoln builds precision metal components, state-of-the-art electronic controls, and the industry’s top-performing pump ® BearingSaver systems. Our quality systems in the United States and Germany are ISO 9001 registered. With five technical support Research & Development centers on three continents, and a network of systems houses and distributors supported by regional sales and service offices, our customers can always draw on our worldwide resources. To make sure your investment results in significant savings, Lincoln developed a unique Mobile Equipment ® program called BearingSaver . You not only get a complete audit of your facility, you also receive an analysis of your return on investment. ® Centro-Matic Automated Lubrication Systems Table of Contents ® Introduction to Centro-Matic . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Grease Injectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Oil Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Metric Injectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Injector Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 P653S Electric Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 P603S Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Manual Grease Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Air-Operated Grease Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Electric Grease Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Manually Operated Oil Pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Air-Operated Oil Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Electric-Operated Oil Pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Bucket Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 ® FlowMaster Hydraulic Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 ® FlowMaster Electric Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Hydraulic-Powered Grease Pumps. . . . . . . . . . . . . . . . . . . . . . . . 36 Airless Spray Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Pump Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 System Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Numerical Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 1 ® Centro-Matic Automated Lubrication Systems Introduction ® Lincoln Centro-Matic systems and components are made to match your application. Systems can service one machine, different zones on one machine or even several separate machines. Regardless of the application, the principle of centralized lubrication remains the same: a central pump station automatically delivers lubricant through a single supply line to the injectors. Each injector serves only one lubrication point and may be accurately adjusted to deliver the precise amount of grease or oil required. Centro-Matic systems give you multiple advantages over other designs. Simplicity Systems are easy to understand, install and maintain. You realize savings right from the start because one lubricant supply line means lower installation costs. Powerful Pumping Unit Centro-Matic systems dispense either grease or oil in measured quantities, unaffected by normal temperature or viscosity changes. For large systems, Lincoln’s single-line design and powerful pumps mean injectors can be located long distances from original refinery containers or bulk lubricant tanks. External Adjustment Lubricant injectors are externally adjustable without special tools so each bearing can receive the correct amount of lubricant. No under- or over-lubrication at individual points. Visual Indicators Each injector incorporates an indicator pin that gives visual confirmation the injector is operating correctly. When necessary, troubleshooting is the simple process of checking indicator pins. Ease of Service When injectors finally need service, the job is quick and easy. No need to remove supply line connections or disturb adjacent injectors. Replacement can usually be done between lubrication cycles, so there’s almost no lubricant loss or downtime. Parts and Service You’re never far from a Lincoln authorized distributor. Qualified distributors offer design engineering, startup help and training for your personnel in the use and maintenance of Centro-Matic systems. They’ll back you up with parts and service for years after the sale. Air-Operated Electric Manual Hydraulic Actuated automatically by Used where compressed air Designed for smaller, A complete hydraulically- compressed air at various is not available, or electrical individual machines, manual powered pumping unit for pre-determined intervals. operation is preferred. Totally systems provide a low-cost, centralized lubrication of An air-operated pump enclosed motor supplies the efficient method of distribut- individual machines. Usually delivers lubricant to the power requirements of the ing lubricant to the injectors. installed on machinery such injectors. When all injectors pumping mechanism. Time Cycling a complete bank of as coal mining and earth have cycled, the pump shuts control is adjustable to injectors takes only a few moving equipment which off automatically and vents provide predetermined seconds. In manually- utilize a hydraulic pressure lubricant pressure. Available frequency of lubrication. operated systems, the system. The frequency of with automatic, manual or lubricant pump is hand- the lubrication cycle can be mechanical controls. operated and the machine set manually or by mechani- operator performs the cal or automatic controls. lubrication intervals. 2 ® Centro-Matic Automated Lubrication Systems Introduction ® Basic Operating Principles of Centro-Matic Injectors Each Lincoln Centro-Matic injector can be manually adjusted to discharge the precise amount of lubricant each bearing needs. Injectors are mounted singly at each bearing, or grouped in a manifold with feedlines supplying lubricant to the bearings. In each case, injectors are supplied with lubricant under pump pressure through a single supply line. Two injector types are available: a top adjusting and a side adjusting. Both types can be used in the same circuit; their selection is made on the basis of bearing lubricant requirements. Indicator Indicator Indicator Indicator Stem Stem Stem Stem Discharge Discharge Discharge Discharge Chamber Chamber Chamber Chamber Measuring Measuring Measuring Measuring Piston Piston Piston Piston Slide Slide Slide Slide Valve Valve Valve Valve Stage 1 Stage 2 Stage 4 Stage 3 SL-V, SL-V XL Stage 1—The discharge chamber is filled with lubricant from the previous cycle. Under pressure of incoming lubricant, lubricant is directed to both sides of the measuring piston through the slide valve. The port to the bearing is closed in this position which prevents the measuring piston from moving. The indicator stem will be at its innermost position, having pulled away from the stop in the adjusting screw. Stage 2—Pressure has built up and has moved the slide valve in position shown. This closes the flow passage to the upper side of the piston (larger diameter) while simultaneously opening the port to allow lubricant to flow out of the injector to the bearing. Pressure from the supply line continues to apply pressure to the lower portion of the measuring piston, which causes a pressure difference across the measuring piston thus allowing it to move upward. Stage 3—Movement of the measuring piston is shown caused by the pressure on the lower side of the measuring pis- ton dispensing lubricant out to the bearing. The indicator stem will move up against the stop in the adjusting screw when all lubricant has been delivered to the bearing. Stage 4—As the pressure in the supply line is vented down to 1,000 psi, the slide valve moves back to its rest position. Flow of lubricant to the bearing is closed and simultaneously allows lubricant to flow to the upper (larger diameter) of the piston. The displacement of fluid on the lower side of the measuring chamber is also allowed by the slide valve to flow to the upper side of the piston. The injector is recharged by the residual pressure in the supply line to the upper portion of the measuring chamber. 3 ® Centro-Matic Automated Lubrication Systems Introduction Indicator Stem Injector Piston Measuring Injector Chamber Piston Discharge Chamber Discharge Chamber Slide Outlet Slide Valve Port Valve Passage Passage Lubricant Supply Inlet Stage 1 Stage 2 Stage 3 Stage 4 SL-1, -11, -41, -44 Stage 1—The injector piston is in its normal, or rest position. The discharge chamber is filled with lubricant from the previous cycle. Under the pressure of incoming lubricant, the slide valve is about to open the passage leading to the piston. Stage 2—When the slide valve uncovers the passage, lubricant is admitted to the top of the piston, forcing the piston down. The piston forces lubricant from the discharge chamber through the outlet port to the bearing. Stage 3—As the piston completes its stroke, it pushes the slide valve past the passage, cutting off further admission of lubricant to the passage. Piston and slide valve remain in this position until lubricant pressure in the supply line is vented (relieved) at the pump. Stage 4—After pressure is relieved, the compressed spring moves the slide valve to the closed position. This opens the port from the measuring chamber and permits the lubricant to be transferred from the top of the piston to the discharge chamber. SL-32, -33, -42, -43 Stage 1—Incoming lubricant, under pressure from the supply line, moves the injector piston forward. The piston Measuring forces a pre-charge of lubricant from the discharge Outlet Chamber Check chamber through the outlet check valve to the feed line. Valve Lock Nut Discharge Stage 2—When the system is vented (pressure relieved), the Chamber piston returns to the rest position, transferring lubricant from the measuring chamber to the discharge chamber. Applications—When it comes to eliminating costly, manual point-by-point lubrication, Centro-Matic systems Adjusting have proven to be the right solution for many industries Nut and applications. Examples include: Indicator Lubricant Stem Supply • Paper Converting • Printing • Food & Beverage Inlet Injector • Plastic Processing • Packaging • Metalworking Piston • Wood Processing • Textile • Material Handling Stage 1 Stage 2 Equipment 4 ® Centro-Matic Automated Lubrication Systems Grease Injectors Series SL-33 • For single-line, high-pressure central lubrication system. • For dispensing petroleum-based lubricants with a viscosity up to NLGI No. 2 (refer to Design Guide). • Output is externally adjustable. • Indicator stem permits visual check of injector operation. • May be combined in a circuit of Injectors SL-32, SL-V, SL-V XL, SL-1 and/or SL-11. • Individual injectors can be easily removed for inspection or replacement. • Available in stainless steel SAE 304, for application where environmental conditions are hazardous to carbon steel or in industries preferring stainless steel. Specifications: Output Operating Pressure Series Min. Max. Min. Max. Typical Vent .001 cu. in. .003 cu. in. 1200 psig 3500 psig 1500 psig 200 psig SL-33 .016 cc .049 cc 83 bar 241 bar 103 bar 14 bar Model Connections Dimensions A B Carbon Stainless Manifold Injector Number of Steel Steel (304) Inlet Outlet Outlets in. mm in. mm 1 5 83309-1 83715-1 1 1 ⁄8 29 1 ⁄8 41 7 3 83309-2 83715-2 2 1 ⁄8 48 2 ⁄8 60 5 1 83309-3 83715-3 3 2 ⁄8 67 3 ⁄8 79 1 3 7 83309-4 83715-4 4 ⁄8" NPTF (F) 3 ⁄8 86 3 ⁄8 98 1 1 5 83309-5 — 5 ⁄8" O.D. Tube 4 ⁄8 105 4 ⁄8 117 7 3 83309-6 83715-6 6 4 ⁄8 124 5 ⁄8 137 5 1 — 83715-7 7 5 ⁄8 143 6 ⁄8 156 1 83900 83900-9 1 ⁄8" NPTF (M) Single Injector/No Manifold 83314 83314-9 — — Single Replacement Injector Notes: 1 1. Injectors, except replacement injectors for manifold, include compression nut and ferrule for tubing — ⁄8" O.D. as standard. Other outlet connectors for feed line optional. 2. Injectors with manifolds include two mounting clips and screws. 3. Injectors have Nitrile packings (200°F max. / 93°C). Check packing compatibility with synthetic lubricants. 4. Output with indicator cap hand-tightened is .001 cu. in. Maximum output is achieved with two turns at .001 cu. in./turn. 5 ® Centro-Matic Automated Lubrication Systems Grease Injectors Series SL-32 • For single-line, high-pressure central lubrication system. • For dispensing petroleum-based lubricants with a viscosity up to NLGI No.2 (refer to Design Guide). • Output is externally adjustable. • Indicator stem permits visual check of injector operation. • May be combined in a circuit of injectors SL-33, SL-V, SL-V XL, SL-1 and/or SL-11. • Individual injectors can be easily removed for inspection or replacement. • Available in stainless steel SAE 304, for application where environmental conditions are hazardous to carbon steel or in industries preferring stainless steel. Specifications: Output Operating Pressure Series Min. Max. Min. Max. Typical Vent .001 cu. in. .008 cu. in. 1200 psig 3500 psig 1500 psig 200 psig SL-32 .016 cc .131 cc 83 bar 241 bar 103 bar 14 bar Model Connections Dimensions A B Carbon Stainless Number of Manifold Injector Steel Steel (304) Outlets Inlet Outlet in. mm in. mm 1 3 83336-1 83724-1 1 1 ⁄4 32 1 ⁄4 44 1 83336-2 83724-2 2 2 51 2 ⁄2 63 1 ⁄4" NPTF (F) 3 1 83336-3 83724-3 3 2 ⁄4 70 3 ⁄4 83 1 ⁄8" O.D. Tube 1 83336-4 83724-4 4 3 ⁄2 89 4 102 1 83338 — 1 ⁄4" NPTF (M) Single Injector/No Manifold 83337 83337-9 — — Single Replacement Injector Notes: 1 1. Injectors, except replacement injectors for manifold, include compression nut and ferrule for tubing — ⁄8" O.D. as standard. Other outlet connectors for feed line optional. 2. Injectors with manifolds include two mounting clips and screws. 3. Injectors have Nitrile packings (200°F max. / 93°C). Check packing compatibility with synthetic lubricants. 4. Output with indicator cap hand-tightened is .001 cu. in. Maximum output is achieved with five turns at .0014 cu. in./turn. 6 ® Centro-Matic Automated Lubrication Systems Grease Injectors 1 4 1 / " (32mm) Series SL-V 1 /8" 3 8 /4" NPTF (222mm) 3 /8" 13 /32" (10.3mm) (19mm) Mounting Holes 1 2 /8" 3 8 / " NPTF (54mm) (both ends) 1 2 1 / " A 3 8 1 / " (38mm) B (35mm) • For single-line, high-pressure central lubrication system. • For dispensing lubricants compatible with polyurethane seals up to NLGI No. 2 (refer to Design Guide). • Output is externally adjustable. • Indicator stem permits visual check of injector operation. • May be combined in a circuit of injectors SL-32, SL-33, SL-1, SL-V XL and/or SL-11. • Individual injectors can be easily removed for inspection or replacement. • Each SL-V injector includes a clear polycarbonate protective cap. Specifications: Output Operating Pressure Connections Series Material Min. Max. Min. Max. Typical Vent Manifold Inlet Injector Outlet 0.015 cu. in. 0.08 cu. in. 1850 psig 6000 psig 2500 psig 1000 psig Carbon 3 1 SL-V ⁄8" NPTF (F) ⁄8" NPTF (F) Steel 0.25 cc 1.31 cc 128 bar 415 bar 170 bar 70 bar Dimension A Dimension B Number of Model Type Outlets in. mm in. mm 1 85770-1 One Injector Manifold 1 2 ⁄2 63 Single Mounting Hole 85770-2 Two Injector Manifold 2 3 76 1 1 85770-3 Three Injector Manifold 3 1 /4 32 4 ⁄4 108 1 85770-4 Four Injector Manifold 4 2 63 5 ⁄2 140 3 3 85770-5 Five Injector Manifold 5 3 ⁄4 95 6 ⁄4 171 85770-6 Six Injector Manifold 6 5 127 8 203 85771 Replacement for manifold injectors 3 85772 Single injector/no manifold ( ⁄8" NPTF(M) inlet) Notes: 13 3 1. Injector manifolds have ⁄32" (10.3 mm) dia. mounting holes for ⁄8" bolt. 2. Injectors have polyurethane seals Check compatibility with synthetic lubricants. 3. Injector rated for 180°F (80°C) max. ambient temperature, depending on lubricant used. 4. Injectors include fitting for filling feedlines via alternate outlet port. 5. Output with adjustment screw hand-tightened is .015 cu. in. Maximum output is achieved with five turns at .014 cu. in./turn. 7 ® Centro-Matic Automated Lubrication Systems Grease Injectors 1 1 /4" Series SL-V XL (32mm) High-Output 3 11 /16" (284mm) 1 /8" NPTF 3 4 13 / " /32" (10.3mm) (19mm) Mounting Holes 1 2 /8" 3 /8" NPTF (54mm) (both ends) 1 1 /2" A 3 1 /8" (38mm) (35mm) B • For single-line, high-pressure central lubrication system. • For dispensing lubricants compatible with polyurethane seals up to NLGI No. 2 (refer to Design Guide). • Output is externally adjustable. • Indicator stem permits visual check of injector operation. • May be combined in a circuit of injectors SL-32, SL-33, SL-1, SL-V and/or SL-11. • Individual injectors can be easily removed for inspection or replacement. • Two SL-V XL injectors are required to replace one SL-11 injector. • Each SL-V XL injector includes a clear polycarbonate protective cap. Specifications: Output Operating Pressure Connections Series Material Min. Max. Min. Max. Typical Vent Manifold Inlet Injector Outlet Carbon 0.015 cu. in. 0.305 cu. in. 1850 psig 6000 psig 2500 psig 1000 psig 3 1 SL-V XL ⁄8" NPTF (F) ⁄8" NPTF (F) Steel 0.25 cc 5.00 cc 128 bar 413 bar 172 bar 69 bar Dimension A Dimension B Number of Model Type Outlets in. mm in. mm 1 85780-1 One Injector Manifold 1 2 ⁄2 63 Single Mounting Hole 85780-2 Two Injector Manifold 2 3 76 1 1 85780-3 Three Injector Manifold 3 1 /4 32 4 ⁄4 108 1 1 85780-4 Four Injector Manifold 4 2 ⁄2 63 5 ⁄2 140 3 3 85780-5 Five Injector Manifold 5 3 ⁄4 95 6 ⁄4 171 85780-6 Six Injector Manifold 6 5 127 8 203 85781 Replacement for manifold injectors 3 85782 Single injector/no manifold ( ⁄8" NPTF(M) inlet) Spectrum Adjustment Sleeves: Model Number Output Ratio from Ratio from Sleeve 3 (10/bag only) in (cc) Minimum Output Maximum Output Color N/A 0.015 (0.25) 1 0.05 NA 85785-1 0.030 (0.50) 2 0.10 red Notes: 85785-2 0.045 (0.75) 3 0.15 silver 1. Injector manifolds have 13/32" (10.3 mm) dia. 85785-3 0.060 (1.00) 4 0.20 gold mounting holes for 3/8" bolt. 85785-4 0.075 (1.25) 5 0.25 green 2. Injectors have polyurethane seals Check compatibility with synthetic lubricants. 85785-5 0.113 (1.88) 7.5 0.37 black 3. Injector rated for 180°F (80°C) max. ambient 85785-6 0.150 (2.50) 10 0.50 purple temperature, depending on lubricant used. 85785-7 0.188 (3.13) 12.5 0.62 blue 4. Injectors include fitting for filling feedlines via alternate outlet port. 85785-8 0.225 (3.75) 15 0.75 orange 5. Output with adjustment screw hand-tightened is .015 85785-9 0.263 (4.38) 17.5 0.87 brown 1 cu. in. Maximum output is achieved with 20 ⁄2 turns at 85785-10 0.300 (5.00) 20 1.00 yellow .014 cu. in./turn. 8 ® Centro-Matic Automated Lubrication Systems Grease Injectors Series SL-1 • For single-line, high-pressure central lubrication system. ® • For dispensing lubricants compatible with Viton packings and viscosity up to NLGI No. 2 (refer to Design Guide). • Output is externally adjustable. • Indicator stem permits visual check of injector operation. • May be combined in a circuit of injectors SL-32, SL-33, SL-V, SL-V XL and/or SL-11. • Individual injectors can be easily removed for inspection or replacement. • Available in stainless steel SAE 316, for application where environmental conditions are hazardous to carbon steel or in industries preferring stainless steel. Specifications: Output Operating Pressure Connections Series Min. Max. Min. Max. Typical Vent Manifold Inlet Injector Outlet .008 cu. in. .080 cu. in. 1850 psig 3500 psig 2500 psig 600 psig 3 1 SL-1 ⁄8" NPTF (F) ⁄8" NPTF (F) .131 cc 1.31 cc 127 bar 241 bar 172 bar 41 bar Model Dimensions A B A B Carbon Stainless Outlets Number of Steel Steel (316) in mm in mm 1 81770-1 239351* One Injector Manifold 1 2 ⁄2 63 Single Mounting Hole 81770-2 239352* Two Injector Manifold 2 3 76 1 1 81770-3 239353* Three Injector Manifold 3 1 ⁄4 32 4 ⁄4 108 1 1 81770-4 239354* Four Injector Manifold 4 2 ⁄2 63 5 ⁄2 140 3 3 81770-5 239355* Five Injector Manifold 5 3 ⁄4 95 6 ⁄4 171 81770-6 — 6 5 23 8 203 3 81713 — Single injector/no manifold, [ ⁄8" NPTF (M) inlet] Replacement for manifolded injectors 81713A 84776* Injector * For complete assembly, you must order stainless steel manifold and corresponding quantity of Model #84776 Injectors separately. Notes: 13 3 1. Injector manifolds have ⁄32" (10.3 mm) dia. mounting holes for ⁄8" bolt. ® 2. Injectors have Viton packings. Check compatibility with synthetic lubricants. 3. Injector rated for 350°F (176°C) max. ambient temperature, depending on lubricant used. 4. Injectors include fitting for filling feedlines via alternate outlet port. 5. Output with adjustment screw hand-tightened is .009 cu. in. Maximum output is achieved with eight turns at .009 cu. in./turn. 9 ® Centro-Matic Automated Lubrication Systems Grease Injectors Series SL-11 • For single-line, high-pressure central lubrication system. ® • For dispensing lubricants compatible with Viton packings and viscosity up to NLGI No. 2 (refer to Design Guide). • Output is externally adjustable. • Indicator stem permits visual check of injector operation. • May be combined in a circuit of injectors SL-32, SL-33, SL-V, SL-V XL and/or SL-1. 1 • Available only as single unit with ⁄2" NPTF Female inlet. Specifications: Output Operating Pressure Series Min. Max. Min. Max. Typical Vent .050 cu. in. .500 cu. in. 1000 psig 3500 psig 2500 psig 800 psig SL-11 .82 cc 8.2 cc 69 bar 241 bar 172 bar 55 bar Connections M Mo od de ell Number of Outlets Carbon Steel Inlet Outlet 1 1 85497 1 ⁄2" NPTF (F) ⁄4" NPTF (F) Notes: ® 1. Injectors have Viton packings. Check packing compatibility with synthetic lubricants. 2. Injector rated for 350°F (176°C) max. ambient temperature. 3. Injectors supplied with fitting for filling feed line via alternate outlet port. 1 4. Output with adjustment screw hand-tightened is .05 cu. in. Maximum output is achieved with 11 /2 turns at .040 cu. in./turn. 10 ® Centro-Matic Automated Lubrication Systems Oil Injectors Series SL-42 • For single-line central lubrication system. • For dispensing fluid or semi-fluid lubricants. • Output is externally adjustable. • Indicator stem permits visual check of injector operation. • May be combined in a circuit of injectors SL-43, SL-41 and/or SL-44. • Individual injectors can be easily removed for inspection or replacement. ® • Carbon steel injectors with Nitrile or Viton packings. ® • Injectors with Viton packings are used for heat resistant applications or when lubricant to be dispensed requires ® Viton packings for compatibility (indicated by black adjustment caps). Specifications: Output Operating Pressure Series Min. Max. Min. Max. Typical Vent .001 cu. in. .003 cu. in. 750 psig 1000 psig 850 psig 150 psig SL-42 .016 cc .049 cc 52 bar 69 bar 59 bar 10 bar Model Connections Dimensions A B Manifold/ Injector Standard Heat Resistant Number of Outlets Injector Inlet Outlet in. mm in. mm 1 5 83311-1 84428-1 1 1 ⁄8 29 1 ⁄8 41 7 3 83311-2 84428-2 2 1 ⁄8 48 2 ⁄8 60 5 1 83311-3 84428-3 3 2 ⁄8 67 3 ⁄8 79 3 7 83311-4 84428-4 4 3 ⁄8 86 3 ⁄8 98 1 ⁄8" NPTF (F) 1 1 5 83311-5 84428-5 5 ⁄8" O.D. Tube 4 ⁄8 105 4 ⁄8 117 7 3 83311-6 84428-6 6 Connection 4 ⁄8 124 5 ⁄8 137 7 3 83311-10 84428-10 10 7 ⁄8 200 8 ⁄8 213 5 1 83311-15 84428-15 15 11 ⁄8 295 12 ⁄8 308 1 83535 — 1 ⁄8" NPTF (M) Single Injector/No Manifold 83313 84048 — — Replacement for Manifold Injectors Notes: 1 1. Injectors, except replacement injectors for manifold, include compression nut and ferrule for tubing – ⁄8" O.D. as standard. Other outlet connectors for feed line optional. 2. Injectors with manifolds include two mounting clips and screws. ® 3. Standard injectors have Nitrile packings (200°F/93°C max.); Heat Resistant injectors have Viton packings (350°F/176°C max., depending on lubricant used) and black adjusting cap. Check packing compatibility with synthetic lubricants. 4. Output with indicator cap hand-tightened is .001 cu. in. Maximum output is achieved with two turns at .001 cu. in./turn. 11 ® Centro-Matic Automated Lubrication Systems Oil Injectors Series SL-43 • For single-line central lubrication system. • For dispensing fluids or semi-fluid lubricants. • Output is externally adjustable. • Indicator stem permits visual check of injector operation. • May be combined in a circuit of injectors SL-42, SL-41 and/or SL-44. • Individual injectors can be easily removed for inspection or replacement. ® • Carbon steel injectors with Nitrile or Viton packings. ® • Injectors with Viton packings are used for heat resistant applications or when lubricant to be dispensed requires ® Viton packings for compatibility (indicated by black adjustment caps). Specifications: Output Operating Pressure Series Min. Max. Min. Max. Typical Vent .001 cu. in. .008 cu. in. 750 psig 1000 psig 850 psig 150 psig SL-43 .016 cc .131 cc 52 bar 69 bar 59 bar 10 bar Model Connections Dimensions Carbon Steel A B Manifold/ Injector Number of Outlets Injector Inlet Outlet Standard Heat Resistant in. mm in. mm 1 3 83661-1 84429-1 1 1 ⁄4 32 1 ⁄4 44 1 83661-2 84429-2 2 2 51 2 ⁄2 63 1 1 ⁄4" NPTF (F) ⁄8" O.D. Tube 3 1 83661-3 84429-3 3 2 ⁄4 70 3 ⁄4 83 Connection 1 83661-4 84429-4 4 3 ⁄2 89 4 102 83660 84110 — — Replacement for Manifold Injectors Notes: 1 1. Injectors, except replacement injectors for manifold, include compression nut and ferrule for tubing – ⁄8" O.D. as standard. Other outlet connectors for feed line optional. 2. Injectors with manifolds include two mounting clips and screws. 3. Standard injectors have Nitrile packings (200°F/93°C max.) ® 4. Heat Resistant injectors have Viton packings (350°F/176°C max. depending on lubricant used) and Black Adjusting Cap. 5. Check packing compatibility with synthetic lubricants. 6. Output with indicator cap hand-tightened is .001 cu. in. Maximum output is achieved with five turns at .0014 cu. in./turn. 12 ® Centro-Matic Automated Lubrication Systems Oil Injectors Series SL-41 • SL-41 series injectors are designed for use in high temperature applications up to 350°F (176°C), depending on lubricant. 3 • Available installed only in manifolds with ⁄8" NPT female inlet. • Injectors feature a tamper-resistant adjustment screw which does not incorporate a visual indicator. • May be combined in a circuit of injectors SL-42, SL-43 and SL-44. Specifications: Output Operating Pressure Series Min. Max. Min. Max. Typical Vent .008 cu. in. .080 cu. in. 750 psig 1000 psig 850 psig 150 psig SL-41 .131 cc 1.31 cc 52 bar 69 bar 59 bar 10 bar Model Connections Dimensions A B Number of Outlets Manifold/ Injector Carbon Steel Injector Inlet Outlet in. mm in. mm 1 82294-1 1 2 ⁄2 63 Single Hole Mounting 82294-2 2 3 76 3 1 1 1 ⁄8" NPTF (F) ⁄8" NPTF (F) 82294-3 3 1 ⁄4 32 4 ⁄4 108 1 1 82294-4 4 2 ⁄2 63 5 ⁄2 140 3 3 82294-5 5 3 ⁄4 95 6 ⁄4 171 3 82292 Single Injector/No Manifold, [ ⁄8" NPTF (M) Inlet] 1 82295 — — ⁄8" NPTF (F) Replacement for Manifold Injectors Notes: 13 3 1. Injector manifolds have ⁄32" (10.3 mm) mounting holes for ⁄8" bolt. 2. Minimum output (.008 cu. in.) is achieved by hand tightening the adjustment screw, then backing out 9 turns. Maximum output (.08 cu. in.) is achieved by hand tightening the adjustment screw, then backing out 16 turns. 13 ® Centro-Matic Automated Lubrication Systems Oil Injectors Series SL-44 • For single-line central lubrication system. • For dispensing fluid or semi-fluid lubricants. • Output is externally adjustable. • Indicator stem permits visual check of injector operation. • May be combined in a circuit of injectors SL-43, SL-41 and/or SL-42. • Individual injectors can be easily removed for inspection or replacement. ® • Carbon steel injectors with Viton packings. Specifications: Output Operating Pressure Series Min. Max. Min. Max. Typical Vent .008 cu. in. .080 cu. in. 750 psig 1000 psig 850 psig 150 psig SL-44 .131 cc 1.31 cc 52 bar 69 bar 59 bar 10 bar Model Connections Dimensions A B Number of Outlets Manifold Injector Carbon Steel Inlet Outlet in. mm in. mm 1 83749-1 1 2 ⁄2 63 Single Hole Mounting 83749-2 2 3 76 3 1 1 1 83749-3 3 ⁄8" NPTF (F) ⁄8" NPTF (F) 1 ⁄4 32 4 ⁄4 108 1 1 83749-4 4 2 ⁄2 63 5 ⁄2 140 3 3 83749-5 5 3 ⁄4 95 6 ⁄4 171 83748 1 — — Replacement for Manifold Injectors Notes: 13 3 1. Injector manifolds have ⁄32" mounting holes for ⁄8" bolt. ® 2. Injectors have Viton packings. Check packing compatibility with synthetic lubricants. 3. Injectors rated at 350°F (176°C) maximum ambient temperature, depending on lubricant used. 4. Output with adjustment screw hand-tightened is .009 cu. in. Maximum output is achieved with eight turns at .009 cu. in./turn. 14 ® Centro-Matic Automated Lubrication Systems Metric Injectors Series SL-32, 33 and 42 Metric 3 1/16" 1/8" BSPP(F) 78 mm Thread Both Ends 11/16" 18 mm 3/4" 19 mm SL-32 Series SL-33, 42 Series With the same proven design as our U.S. standard injectors, the new metric versions of our popular small grease and oil injectors feature metric ports. Any surface that needs a wrench is metric. It’s more convenient for customers in most of the world, and easier to maintain because there’s no need for a second set of wrenches or adapters. • Offered for international customers. • Metric ports connect with metric lines without adapters. • No need for a second set of tools. • Proven design used in the United States. • Models for both grease and oil. Specifications: Model Connections Dimension A Dimension B Outlets Oil Grease Grease Inlet Outlet in. mm in. mm SL-42 SL-33 SL-32 1 5 85352-1 85351-1 1 1 ⁄8 29 1 ⁄8 41 7 3 85352-2 85351-2 2 1 ⁄8 48 2 ⁄8 60 5 1 85352-3 85351-3 3 2 ⁄8 67 3 ⁄8 79 3 7 85352-4 85351-4 4 3 ⁄8 86 3 ⁄8 98 6 mm 1 5 85352-5 85351-5 5 4 ⁄8 105 4 ⁄8 118 1 ⁄8" BSPP(F) O.D. Tube 7 3 85352-6 85351-6 6 4 ⁄8 124 5 ⁄8 137 Connection 1 3 85353-1 1 1 ⁄4 32 1 ⁄4 44 1 85353-2 2 2 51 2 ⁄2 64 3 1 85353-3 3 2 ⁄4 70 3 ⁄4 83 1 85353-4 4 3 ⁄2 89 4 102 15 ® Centro-Matic Automated Lubrication Systems Injector Accessories Injector Connector Tube Permits application of combined discharge of two or more Series SL-V, SL-1, SL-41 or SL-44 injectors through one feed line. Used where bearing size is such that 1 multiple injector output is required. Fittings ⁄8" NPT male each end. Carbon steel construction. Model For Injector Series Connections 1 81646 SL-V, SL-V XL OR SL1, SL41, SL44 ⁄8" NPTF Male 1 274824 SL-1 to SL-V connection ⁄8" NPTF Male Injector Outlet Adapter 1 Converts individual injector lubricant outlet when standard ⁄8" O.D. tube is not desired. All adapters are carbon steel unless otherwise noted. Model For Injector Series Outlet Connections 1 14988 ⁄8" NPTF Female 1 84200 ⁄4" O.D. Tube 1 14991 SL32, SL33, SL42, SL43 ⁄8" NPTF Male 249281 4 mm Tube 249282 6 mm Tube Manual Grease Fitting Adapter Allows manual lubrication of the machine between normal system cycles. Carbon steel with Nitrile seals. Model For Injector Series Outlet Connections 1 84195 ⁄8" O.D. Tube SL32, SL33, SL42, SL43 1 84203 ⁄4" O.D. Tube Injector Locking Cap Carbon steel locking caps set injectors to fixed output. Fixed Volume Model For Injector Series Output 3 SL32, SL43 .002 in / .033 cc 102781 3 SL33, SL42 .003 in / .049 cc Injector Cover Caps Injector cover caps are designed to protect the injector from dirt, harmful liquids and fumes. Length Diameter Model Fits Injector Series Covers Material in mm in mm 273088 SL-V 1.5 38.1 .715(ID) 18.2 Polycarbonate 273089 SL-V XL Indicator 2.2 55.9 .715(ID) 18.2 83272 SL1, SL44 Stem 1.5 38.1 .69(ID) 17.5 83730 SL11 Vinyl 2.0 50.8 1.125(ID) 28.6 SL32, SL33, Measuring 68483 1.25 31.2 .5(ID) 12.7 SL42, SL43 Chamber 90537 SL1, SL41, SL44 Injector Body Aluminum 3.25 82.6 1.19(ID) 30.2 16 ® Centro-Matic Automated Lubrication Systems Injector Accessories Closure Plugs for Injectors and Manifolds For use in plugging lubricant outlets of injectors and manifolds. Thread AB Model Material Style Size (in) in. / mm in. / mm 12698* Carbon Steel 5 5 1 ⁄16 -24 ⁄16 / 7.9 ⁄2 / 12.7 1 12698-9* Stainless Steel A B 12511 Carbon Steel 1 7 7 ⁄8 PTF ⁄16 / 11.1 ⁄16 / 11.1 2 Style 1 12511-9 Stainless Steel 3 7 13 67044 ⁄8 NPT ⁄16 / 11.1 ⁄16 / 20.6 2 Carbon Steel 67007 1 3 5 ⁄4 NPT ⁄16 / 4.8 ⁄8 / 15.9 2 67007-9 Stainless Steel A B * For plugging outlet of series SL-32, SL-33, SL-42, SL-43 injectors. Style 2 Compression Nuts Thread AB C Model Style Material Size (in) in. / mm in. / mm in. / mm 66260 Brass One Piece 66260-9 Stainless Steel 5 5 1 1 ⁄16-24 ⁄16 / 7.9 ⁄2 / 12.7 ⁄8 / 3.2 83924 Brass Two Piece 83924-9 Stainless Steel 7 7 5 1 66713 One Piece Brass ⁄16-24 ⁄16 / 11.1 ⁄8 / 15.9 ⁄4 / 6.3 Injector-Operated Air Valve Model For Injector Series Air Inlet Air Outlet 1 1 82272 SL-1, SL-44 ⁄8" NPTF(F) ⁄8" NPTF(F) Air Lubricant Spray Devices Use With Air Lubricant Spray Air Model Series Inlet (in) Inlet (in) Outlet Consumption 68421 Fixed Nozzle 3.5 CFM 4.1 CFM 5.2 CFM 1 1 ⁄4 NPTF ⁄4 NPTF 69456 Swivel Nozzle @40 PSI @60 PSI @80 PSI SL1, SL44 Female Female Bulkhead 99 l/min 116 l/min 147 l/min 68587* Mount @2.8 bar @4.1 bar @5.5 bar 1 7 SL32, SL33, ⁄8 NPTF ⁄16 – 24 Fixed 84204 Throttle Controlled SL42, SL43 Female Male Nozzle 3 * ⁄16" (4.8 mm) maximum bulkhead thickness. Metric Outlet Adapters Adapts injector outlet to 4 or 6 mm tubing. Conversion Kit Tubing Material Nut Ferrule Model No. Size 249281 4 mm Carbon Steel 249277 249271 249282 6 mm Carbon Steel 249274 249273 Assembly comes with one nut and one ferrule. Feedline Brush 1 5 ⁄8" NPT(F) inlet, 1" long, ⁄8" surface Use to apply lubricant to chains and conveyors. area diameter; aluminum body with nylon bristles. Model 68874 17 ® Centro-Matic Automated Lubrication Systems P653S Electric Pump Taking Lincoln’s Pump Performance and Dependability In A Totally New Direction The fully integrated P653S pump is an example of Lincoln’scommitment to providing innovative, cost-effective solutions through industry-leading advances in technology. This next-generation, lower-cost pump package can be fitted with one of four reservoir sizes and easily adapts to many applications. P653S Pump Features • Integrated pump supplies lubricant to a single line parallel lubrication system • Pumps low- and high-viscosity greases including industry standard NLGI grade 2 grease • Easily interfaces with telematics technology in today’s heavy equipment • Operating temperature range from -40°F to +158°F (-40°C to +70°C) VDC or 32°F to 122°F (0°C to 50°C) VAC* • Neutral switch allows mobile equipment to remain idling with pump power on but the timer is deactivated – allowing manual lubrication functionality. Benefits • Integration of major system components reduces labor and overall costs • Simplifies lubrication system design • Installation time is reduced due to the ”plug-and-play” pump design. Simply mount the pump, connect power and the supply lines and the system is ready for operation. • Neutral switch ensures lubrication only when the machine is operating – eliminating wasted grease. * Appropriate greases apply INTERNAL COMPONENTS • Telematics Signaling Capabilities for Low Level and System Fault Detection • Pressure Switch or Available With or Transducer Without Follower (shown with follower) Reservoir Available in Four Sizes – High-Volume Output 4, 8, 15, and 20 Liters Means Versatility in Scheduling Refilling Service Intervals Vent Valve Reservoir Refill Port 120/220-AC or 24-DC Pump Programmable Controller 18 ® Centro-Matic Automated Lubrication Systems P653S Electric Pump P653S Pump Specifications Electrical data DC Pumps AC Pumps Incoming voltage: 19 to 31 VDC 100 to 240 VAC Maximum current: 10 amps 1.7 amps Frequency: — 47 to 63 hz Operating temperature: -40°F to +158°F 32°F to 122°F (-40°C to +70°C) (0°C to 50°C) Common Electrical Data for DC and AC Pumps Minimum pause time: 4 min. Maximum pause time: 59 hrs. 59 min. Pause time increments: 1 hr. or 1 min. Maximum pumping time: 10 min. Pump P653S Operating pressure with: Pressure switch: 3,500 psig (240 bar) Pressure transducer (adj.): 1,400 to 4,600 psig (96 to 317 bar) End of line pressure switch and transducer setting: 2,500 psig (172 bar) Number of outlets: 1 3 3 Output: 1.5 in /min (24.6 cm /min) Pump Elements Piston diameter: 7 mm Number of pumping elements (connected together): 3 Available Pump Models NOTE: All models are designed for grease and include stirring paddle and low-level detection. Pumps include remote signaling cable, relief valve, electrical connectors and external pressure switch or transducer (as indicated for each model). Internal & Internal & 120/230 Internal Internal Model Reservoir Follower End-of-Line End-of-Line 24 VDC VAC Pressure Pressure No. Size (L) Plate Pressure Pressure 50/60 Hz Switch Transducer Switch Transducer 80086 X 4 X 80087 X 4 X 80105 X 4 X 80106 X 4 X 80076 X 4 X X 80077 X 4 X X 80109 X 4 X X 80110 X 4 X X 80090 X 8 X 80091 X 8 X 80107 X 8 X 80108 X 8 X 80080 X 8 X X 80081 X 8 X X 80111 X 8 X X 80112 X 8 X X 80082 X 4 X 80083 X 4 X 80084 X 4 X 80085 X 4 X 80072 X 4 X X 80073 X 4 X X 80074 X 4 X X 80075 X 4 X X 80088 X 8 X 80089 X 8 X 80078 X 8 X X 80079 X 8 X X 19 ® Centro-Matic Automated Lubrication Systems P603S Pump The Path to Cost Reduction A lack of lubrication can bring your machines and equipment to a screeching halt. Manual lubrication is often awkward and expensive. Automated lubrication offers an efficient, rational and environmentally friendly solution. From a few lubrication points to a few thousand – Lincoln offers the complete range of lubrication equipment and systems for professional lubrication of construction and mining equipment. Lincoln lubrication systems are based on the principle of grouping lubrication points together that can be serviced from one supply point. Our modules build upon each other – enabling the system to grow in accordance with our customer‘s requirements. This enables us to offer a custom-tailored lubrication solution for individual needs. P603S Pump Features Reliable Operation in Harsh Environments • Wind turbines – especially offshore • Lower costs for repairs and spare parts • Construction and mining • Exactly matched metering reduces the • Commercial vehicles cost of lubricant • Compact and medium-sized machines • Precise metering reduces the and industrial applications environmental impact. No dripping • Robust and easy system layout of “too much” lubricant • Simple maintenance – easy to expand • Improved safety by minimizing slipping • SE1 suction elements for used lubricant • Hard-to-reach points are easily accessi- • Suitable for quick separating lubricants ble from a convenient point – which • Increased profits and productivity also improves safety • Improved operating times; less costly • Reliable supply of all connected lubrica- downtime resulting from improper tion points. No points are “overlooked” lubrication P603S Pump Specifications 3 Incoming metering: 0.05 - 0.4 cm /stroke 3 Pump output: 12 cm Supply voltage: 12 VDC, 24 VDC, 100-240 VAC Visual monitoring (indicator pin): x Programmable controller: x Reservoir capacity/liter: 4, 8, 10, 15, 20 Integrated pressure sensor and vent: x Visual low-level: x Compatible with SE1 suction elements: x Available Pump Models Model No. Description Power Size Follower Transducer 645-41064-3 P603S- 4XLF -3Z7-AC-2A7.16-S13-SE AC 4L X X 645-41062-3 P603S- 8XLF -3Z7-AC-2A7.16-S13-SE AC 8L X X 645-41110-2 P603S- 8XLBO-3Z7-AC-3A7.16-S12-SE AC 8L X 645-41062-4 P603S- 8XLBO-3Z7-AC-3A7.16-S19-SE AC 8L X 645-41062-3 P603S- 8XLF -3Z7-AC-2A7.16-S13-SE AC 8L X X 645-41073-5 P603S-15XLF -3Z7-AC-2A7.16-S13-SE AC 15L X X 645-41064-8 P603S- 4XLF1-3Z7-12-1A7.16-S01-SE 12 DC 4L X (Bayonett) X 645-41064-7 P603S- 4XNBO-3Z7-12-2A7.16-S01-SE 12 DC 4L X 645-41110-3 P603S- 8XLF1-3Z7-12-1A7.16-S01-SE 12 DC 8L X (Bayonett) X 645-41062-9 P603S- 8XLF -3Z7-24-1A7.16-S01-SE 24 DC 8L X X 645-41064-4 P603S- 4XLBO-3Z7-24-1A7.16-S17-SE 24 DC 4L X 645-41064-6 P603S- 4XLF -3Z7-24-1A7.16-S13-SE 24 DC 4L X X 645-41064-2 P603S- 4XNBO-3Z7-24-1A7.16-S01-SE 24 DC 4L X 645-41062-8 P603S- 8XLBO-3Z7-24-2A7.16-S19-SE 24 DC 8L X 645-41062-9 P603S- 8XLF -3Z7-24-1A7.16-S01-SE 24 DC 8L X X 645-41062-7 P603S- 8XLF -3Z7-24-1A7.16-S03-SE 24 DC 8L X X 645-41119-1 P603S-10XLF -3Z7-24-1A7.16-S13-SE 24 DC 10L X X 20 ® Centro-Matic Automated Lubrication Systems P603S Pump Pump and Accessories – All-In-One The pump with integrated controller is easy to install. The all-in-one design of the pump includes the programmable controller, a pressure switch/transducer and a vent valve. Simple System Design – Easy to Expand The single-line system’s design and layout is uncomplicated, making it easy to install and operate. A single mainline reduces material and installation costs. Easy to Service It is quick and easy to exchange out an injector. The mainline or neighboring injec- tors do not have to be removed. The exchange can be performed between lubrica- tion cycles so that there is no wastage of lubricant or excessive costly downtime. Additional Pressure Switch An additional pressure switch at the end of larger systems can be used for added pressure control to ensure correct lubrication Special Features for Wind Turbine Applications – Also for Off-Shore Systems Lincoln single-line systems completely vent during the pause interval. As a result, they are suitable for fast separating lubricants. For rotating operation in wind turbines the reservoir is equipped with a follower plate and stirring paddle – which also facilitates the usage of fast separating lubri- cants. For stationary operation a stirring and fixed paddle is sufficient. Pump Specifications P603S 12/24 VDC P603S / AC Pump output 0.73 cu.in/min (12cm³/min) 0.73 cu.in/min (12cm³/min) Maximum working pressure 4,350 psig (300 bar) / 3,480 psig (240bar) 4,350 psig (300 bar) / 3,480 psig (240bar) Maximum current draw 2 amps 2 amps Steering paddle and follower yes yes Reservoir size, liter 4, 8, 10, 15 and 20 4, 8, 10, 15 and 20 Number of pumping elements 3, (seven millimeter dia.) 3, (seven millimeter dia.) RPM, paddle (76 F) 18 18 Pressure switch at pump yes yes Transducer at pump yes yes Pressure switch/ end of line yes yes Transducer/end of line yes yes PCB yes yes Separate alarms, LL/Proxy switch no no 24.0 VDC input yes yes Switching power supply no yes Connectors Bayonets style Bayonets style + square type (AC) Data logger no no Remotely change lube frequency yes yes Count control yes yes Ignition & Neutral Switch yes yes Acknowledging fault at pump/external at pump/external Manually lub switch, external yes yes Pump on LED, external yes yes Protetecion IP 6K9K IP 6K9K Temperature -40°C / +70°C -40°C / +70°C 21 ® Centro-Matic Automated Lubrication Systems Manual Grease Pumps Once you have determined your total lubricant requirements, your greatest line length and compensated for line expansion, you’re ready to determine the pump you need. If your overall requirements are less than 2.4 cu. in. for oil or 2.15 cu. in. for grease, you can select a single stroke pump. Should your requirements demand more capacity, a reciprocating pump will fill the need. Your Lincoln representative will suggest the best pump for you based on your application. Look over the following pages of pump selection options and feel free to ask questions. Model 83817 Economy Grease Pump Manual pump has metal reservoir and spring-loaded follower. Indicator pin in pump base shows when 2500 psi system operating pressure has been achieved. Model: 83817 Output/Stroke: .100 cu. in. 1.6 cc Reservoir Capacity: 1 lb. .45 kg 30 cu. in. 492 cc 1 Lube Outlet: ⁄8" NPTF (F) Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 241 bar 1 5 Dimensions (HxWxL): 15 ⁄4" x 5 "x 5 ⁄8" 387 x 127 x 141 mm Filling Method: 14.6 oz. Grease Cartridge/Bulk Fill Model 1810 Grease Pump Translucent reservoir with spring-loaded follower. Indicator pin in pump base shows when 2500 psi system operating pressure has been achieved. Refill through included fitting using Model 81834 filler pump or other manual pump equipped with Model 645006 coupler. Model: 1810 Output/Stroke: .160 cu. in. 2.6 cc Reservoir Capacity: 5 lb. 2.27 kg 150 cu. in. 2458.50 cc 1 Lube Outlet: ⁄4" NPTF (F) Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 241 bar 1 1 3 Dimensions (HxWxL): 16 ⁄4" x 7 ⁄8 "x 7 ⁄4" 413 x 181 x 197 mm Filling Method: 81834 Filler Pump 22 ® Centro-Matic Automated Lubrication Systems Air-Operated (Single Stroke) Grease Pumps ® Centro-Matic Integrated Pumps All models are air-operated, positive displacement pumps delivering a maximum volume by means of a single stroke of the pump (volumes listed below). Solenoid air valves and adjustable solid-state time controls are integrated into the pump body. All pumps are designed to deliver grease to single-line injectors and include a special high-volume refill fitting. Acrylic reservoirs are available in several sizes. Integrated controls feature LED indicators for “Power On”, “Pump On” and “Alarm,” along with a membrane-type, “Manual Lube” switch. Model 85434 Integrated Grease Pump Ratio: 31:1 Power: 120 VAC Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 240 bar 3 3 Maximum Output: 1.4 in 18.7 cm Reservoir Capacity: 4.5 lbs. 1.8 kg Dimensions (LxWxH): 24.70" x 6.52"x 18.11" 627 x 166 x 460 mm Model 85435 Integrated Grease Pump Same as Model 85434 except 240 VAC. Model 85434 Model 85436 Integrated Grease Pump Same as Model 85434 except with a Ratio of 25:1 and Maximum Output of 3 3 2.15 in (35.2 cm ). Model 85442 Integrated Grease Pump Ratio: 20:1 Power: 120 VAC Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 240 bar 3 3 Maximum Output: 0.45 in 7.4 cm Reservoir Capacity: 1 lb. 0.450 kg Dimensions (LxWxH): 5.25" x 7.24"x 12.02" 133 x 184 x 305 mm Model 85444 Integrated Grease Pump Ratio: 20:1 Power: 120 VAC Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 240 bar 3 3 Maximum Output: 0.45 in 7.4 cm Model 85442 Reservoir Capacity: 4 lbs. 1.8 kg Dimensions (LxWxH): 5.25" x 7.24"x 20.75" 133 x 184 x 527 mm Model 85445 Integrated Grease Pump Same as Model 85444 except 240 VAC. Timer and Controller Specifications On Off Alarm Operating Time Time Contacts Temperature 10 sec 1/2 to 30 min 8 amps -10°F to 150°F or 30 sec or 30 min to 30 hrs @ 250 VAC -23°C to 65°C 23 ® Centro-Matic Automated Lubrication Systems Air–Operated (Single Stroke) Grease Pumps Model 82886 Pump Pump discharges lubricant on air-powered forward stroke and vents on spring- powered return stroke through built-in check/vent valve. Reservoir is translucent with spring-loaded follower. Includes filler fitting for refilling reservoir with Model 81834 or other manual pump equipped with Model 645006 coupler. Model 83668 Same as Model 82886 except includes larger reservoir. Model 82653 Bare Pump Model 82886 Pump uses air for forward and return stroke but dispenses lubricant on forward stroke only. Return stroke vents lubricant pressure through included check/vent valve. Translucent reservoir has spring-loaded follower. Refill through included filler fitting using Model 81834 or other manual pump equipped with Model 645006 coupler. Model 83834 High Volume Bare Pump Same as Model 82653 except 25:1 ratio, 2.15 cu. in (35.2 cc) maximum output. Model 83668 Model 82655 Pump with Controls Same as Model 82653 except includes Model 84501 solid state timer and 350244 four way electric solenoid valve. Model 83800 High Volume Pump with Controls Same as Model 83834 except includes Model 84501 solid state timer and 350244 Model 82653 four way electric solenoid valve. Lubricant Oper. Lubricant/ Max. Reservoir Reservoir Air Lube Dimensions Air Valve Model Pressure Air Ratio Output Capacity Temp. Range Inlet Outlet HxWxL Required Min. Max. 3 1 10 ⁄8"x5 ⁄4"x6 82886 1 lb/.45 kg 3 263x133x152mm .45 in 3 20:1 30 in /492 3-way 3 1 1 7.4 cm 18 ⁄2"x5 ⁄4"x6 3 83668 cm 470x133x152mm 82653 3 0°F to 150°F 1200 psig 3500 psig 1 1 1.4 in ⁄4" NPTF(F) ⁄4" NPTF(F) 3:1 3 -18°C to 65°C 82 bar 240 bar 22.9 cm 82655 4 lb/1.81 kg 1 3 18 ⁄2"x5 ⁄4"x21 3 120 in / 4-way 470x146x533mm 83834 3 3 1967 cm 2.15 in 25:1 3 35.2 cm 83800 Note: Air consumption @ 100 psi is .15 CFM per stroke. Timer Specifications Cycle Time On Time Power Ambient Operating Min Max Min Max Requirements Temp. Range 120 VAC, 60 hz -10°F to +150°F 20 Sec. 24 Hr. 10 Sec. 1 Min. 24 Sec. 110 VAC, 50 hz -23°C +65°C Note: Refer to System Controls section for detailed timer and solenoid operated air valve specifications. 24 ® Centro-Matic Automated Lubrication Systems Air–Operated (Reciprocating) Grease Pumps Model 83167 Includes transparent reservoir, spring-loaded follower, vent valve assembly and filler fitting for refilling of reservoir with 81834 filler pump or other manual pump equipped with Model 645006 coupler. Model: 83167 Lubricant/Air Ratio: 40:1 Output/Min @ 100 PSIG Air: 12 cu. in. 197 cc Reservoir Capacity: 12 lb. / 5.44 kg 360 cu. in. / 5900 cc Air Inlet: ¹⁄₈" NPTF (F) Lube Outlet: ³⁄₄" NPTF (F) Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 241 bar Dimensions (HxWxL): 22¹⁄₂" x 9 "x 16¹⁄₄" 572 x 229 x 413 mm Filling Method: 81834 Filler Pump Reservoir: Translucent Acrylic Notes: 1. Pump requires 3-way air valve. 2. Air consumption @ 100 psi is .15 CFM per cycle Model 83599 Same as Model 83167 except includes base mounting kit and metal reservoir with indicator rod for visual check of grease level. Reservoir includes spring- loaded follower. Model: 83599 Lubricant/Air Ratio: 40:1 Output/Min @ 100 PSIG Air: 12 cu. in. 197 cc Reservoir Capacity: 12 lb. / 5.44 kg 360 cu. in. / 5900 cc Air Inlet: ¹⁄₄" NPTF (F) Lube Outlet: ³⁄₄" NPTF (F) Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 241 bar Dimensions (HxWxL): 24³⁄₈" x 9 "x 18³⁄₁₆" 619 x 229 x 462 mm Filling Method: 81834 Filler Pump Reservoir: Aluminum Notes: 1. Pump requires 3-way air valve. 2. Air consumption @ 100 psi is .15 CFM per cycle 25 ® Centro-Matic Automated Lubrication Systems Air–Operated (Reciprocating) Grease Pumps Model 1823 1 Includes 2 ⁄2" air motor driven pump, vent valve assembly, pump elevator, connecting lubricant and air hoses, and control panel. Model: 1823 Lubricant/Air Ratio: 50:1 Output/Min @ 100 PSIG Air: 30 cu. in. 492 cc Drum Size: U.S. standard 120 lb. refinery drum 3 Air Inlet: ⁄8" NPTF (F) 3 Lube Outlet: ⁄4" NPTF (F) Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 241 bar Components Pump & Vent Assembly 282288 Included: Controller 85209 Pump Elevator 83447 Controller Electrical Requirements: 120V, 60 Hz., 110 V, 50hz Notes: 1. Air consumption @ 100 psi is .42 CFM per cycle. 2. Model 83371 follower plate is available as an optional accessory. Model 282288 Same specifications as Model 1823 but does not include elevator or controller. Model 1827 Heavy-Duty Unit Consists of PowerMaster pump, vent valve assembly with air and lubricant connecting hoses, drum cover and control panel. Model: 1827 Lubricant/Air Ratio: 75:1 Output/Min @ 100 PSIG Air: 161 cu. in. 2638 cc Drum Size: U.S. standard 400 lb. refinery drum 3 Air Inlet: ⁄8" NPTF (F) 3 Lube Outlet: ⁄4" NPTF (F) Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 241 bar Components Basic Pump 2004 Included: Vent Valve 85215 Controller 85209 Drum Cover 81675 Model 1828 Same as Model 1827 except includes Model 2008 pump, 85218 vent valve and Model 84034 drum cover sized for U.S. standard 120 lb. refinery drum. Includes 85209 controller. Model 1829 Same as Model 1827 except includes Model 2010 pump (50:1 ratio, 231 cu. in./min. (3785 cc) delivery at 100 psig air). Fits U.S. standard 400 lb. refinery drum. Includes 85209 controller and 85215 vent valve. 26 ® Centro-Matic Automated Lubrication Systems Electric Grease Pumps / Manually Operated Oil Pump Model 1849 Fully automatic assembly including pump, 220/440 volt motor, translucent reservoir with spring-loaded follower, 4000 psi (276 bar) safety unloader, adjustable pressure switch and time control. Time control is adjustable for lubrication cycle frequency of 5, 10, 15, 20, 30 or 60 minutes. Solid state time delay relay (35 sec. to 240 sec.) included for connection of audible or visual alarm to signal lubrication failure due to empty reservoir or broken supply line. Model: 1849 * Output/Min: 18 cu. in. 295 cc Reservoir Capacity: 12 lb. / 5.44 kg 360 cu. in. / 5900 cc 1 Lube Outlet: ⁄4" NPTF (F) Electrical Specifications: Pump Motor 220/440 VAC, 60 Hz, 3 ph Controller 115 VAC, 60 Hz Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 241 bar 3 13 Dimensions (HxWxL): 25 ⁄8" x 13 "x 19 ⁄16" 645 x 330 x 503 mm Reservoir Fill Method: 81834 Filler Pump or Manual Pump and 645006 Coupler * See Model 85520 in Systems Control section for controller specifications. Model 1835 Same as Model 1849 except has 115 VAC, 60 Hz motor and controller. Model 1833 Similar to Model 1849 except: 24 VDC pump motor and controller; metal reservoir with visual level indicator rod; 2.5, 5, 10, 20, 40 and 80 minute cycle frequency adjustment; 60 second fixed on time and alarm relay features. Incorporates pressure switch factory set at 2500 psi (172 bar). Model: 1833 Output/Min: 18 cu. in. 295 cc Reservoir Capacity: 12 lb. / 5.44 kg 360 cu. in. / 5900 cc 1 Lube Outlet: ⁄4" NPTF (F) Electrical Specifications: 1 Pump Motor ⁄4 HP, 24 VD, 10 AMP Controller 24 VDC, 5 watts Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 241 bar 1 1 3 Dimensions (HxWxL): 34 ⁄4" x 11 ⁄2"x 21 ⁄4" 870 x 292 x 552 mm Reservoir Fill Method: 81834 Filler Pump or Manual Pump with 645006 Coupler Notes: 1. Controller has provision for remote manual lube button and remote lube failure alarm. 2. Enclosure is designed to meet NEMA 3S and 12 specifications. Manually–Operated Oil Pump Model 1812 Pump has translucent reservoir with filler cap and strainer. Pump base has built-in check/vent valve and an indicator pin to show when system pressure is achieved. Model: 1812 Output/Stroke: .160 cu. in. 2.6 cc Reservoir Capacity: 4¹⁄₂ pint /130 cu. in. 2.13 liter/2130 cc Lube Outlet: ¹⁄₄" NPTF (F) Typical System Min. 750 psig 52 bar Operating Pressure: Max. 1000 psig 69 bar Dimensions (HxWxL): 16³⁄₄" x 7¹⁄₈"x 7³⁄₄" 425 x 181 x 197 mm Note: Check compatibility when using synthetic oils. 27 ® Centro-Matic Automated Lubrication Systems Air–Operated (Single Stroke) Oil Pumps ® Centro-Matic Integrated Pumps All models are air-operated, positive displacement pumps delivering a maximum volume by means of a single stroke of the pump (volumes listed below). Solenoid air valves and adjustable solid-state time controls are integrated into the pump body. All pumps are designed to deliver fluid lubricants to single-line injectors and are filled via a spring-loaded filler cap and internal filter. Acrylic reservoirs are available in several sizes. Pump Models 85432 and 85433 do not include a reser- voir, and are designed for remote or bulk-fill oil applications (80 psi/5.4 bar maximum head pressure). Integrated controls feature LED indicators for “Power On”, “Pump On” and “Alarm,” along with a membrane-type, “Manual Lube” switch. Model 85430 Integrated Fluid Pump Ratio: 20:1 Power: 120 VAC Typical System Min. 750 psig 52 bar Operating Pressure: Max. 1000 psig 69 bar 3 3 Maximum Output: 2.4 in 39.3 cm Model 85430 Reservoir Capacity: 4.5 pints 2.1 liters Dimensions (LxWxH): 24.70" x 6.52"x 18.11" 627 x 166 x 460 mm Model 85431 Integrated Fluid Pump Same as Model 85430 except 240 VAC. Model 85432 Integrated Fluid Pump Same as Model 85430 except without reservoir. Model 85433 Integrated Fluid Pump Same as Model 85432 except 240 VAC. Model 85432 Model 85438 Integrated Fluid Pump Ratio: 20:1 Power: 120 VAC Typical System Min. 750 psig 52 bar Operating Pressure: Max. 1000 psig 69 bar 3 3 Maximum Output: 0.45 in 7.4 cm Reservoir Capacity: 1.25 pints 0.6 liters Dimensions (LxWxH): 5.25" x 7.24"x 12.02" 133 x 184 x 305 mm Model 85440 Integrated Fluid Pump Ratio: 20:1 Power: 120 VAC Typical System Min. 750 psig 52 bar Model 85438 Operating Pressure: Max. 1000 psig 69 bar 3 3 Maximum Output: 0.45 in 7.4 cm Reservoir Capacity: 4.25 pints 2.0 liters Dimensions (LxWxH): 5.25" x 7.24"x 20.75" 133 x 184 x 527 mm Model 85441 Integrated Fluid Pump Same as Model 85440 except 240 VAC. Timer and Controller Specifications On Off Alarm Operating Time Time Contacts Temperature 10 sec 1/2 to 30 min 8 amps -10°F to 150°F or 30 sec or 30 min to 30 hrs @ 250 VAC -23°C to 65°C Model 85440 28 ® Centro-Matic Automated Lubrication Systems Air–Operated (Single-Stroke) Oil Pumps Model 82885 Pump discharges lubricant on air-powered forward stroke and vents on spring- powered return stroke through built-in check/vent valve. Translucent reservoir is refilled through filler cap with strainer. Model 83667 Same as Model 82885 except includes larger reservoir. Model 82570 High-volume pump discharges lubricant on air-powered forward stroke and vents Model 82885 through included check/vent valve on air-powered return stroke. Translucent reservoir is refilled through filler cap with strainer. Model 82573 Air-operated, single stroke oil pump and timer assembly. Same as Model 82570 except includes Model 84501 solid state timer and 350244 four-way electrical solenoid valve. Power requirements: 120 VAC, 60 Hz; 110 VAC, 50 Hz. Model 83667 Model 82676 1 Same as Model 82570 except for use with external oil supply through ⁄2" NPT(F) oil inlet (maximum head pressure 80 psi (5.5 bar)). Model 82676 Metric Lubricant/ Max Reservoir Air Lube Lubricant Dimensions Air Model Equiv Air Output Capacity Inlet Outlet Oper. Press. HxWxL Valve Ratio Min Max Required 1 3 1 1 ⁄4 pint/.6 liter 10 ⁄8"x5 ⁄4"x6" 82885 85391 3 3 3 263x133x152mm .45 in 36 in /600cm 3-way 3 1 1 7.4 cm 750 1000 ⁄2 ⁄2 18 "x5 "x6" 83667 1 1 ⁄4" ⁄4" psig psig 470x140x152mm 1 20:1 4 ⁄2 pint / 2 liter NPTF(F) NPTF(F) 52 69 3 3 1 82570 3 3 17 ⁄4"x5 ⁄4"x18 ⁄4" 123 in / 2000 cm bar bar 3 451x146x464mm 82573 2.4 in 4-way 3 1 3 39.3 cm 18 ⁄2"x5 ⁄4"x21" Remote 82676 470x146x533mm ** Air consumption @ 100 psi is .15 CFM per stroke. Check compatibility when using synthetic oils. Timer Specifications for Model 82573 Only Cycle Time On Time Min Max Min Max 20 Sec. 24 Hr. 10 Sec. 1 Min. 24 Sec. Note: Refer to System Controls section for detailed timer and solenoid-operated air valve specifications. 29 ® Centro-Matic Automated Lubrication Systems Air–Operated (Reciprocating) Oil Pumps Model 283167 1 Includes 2 ⁄2" air motor driven pump, vent valve assembly, translucent reservoir with filler cap and strainer and 1200 psi (82 bar) safety unloader. Model: 283167 Lubricant/Air Ratio: 40:1 Output/Min @ 100 PSI Air: 12 cu. in. 197 cc Reservoir Capacity: 15 pint 7.1 liter 433 cu. in. 7100 cc 1 Air Inlet: ⁄8" NPTF (F) 3 Lube Outlet: ⁄4" NPTF (F) Typical System Min. 750 psig 52 bar Operating Pressure: Max. 1000 psig 69 bar 1 1 Dimensions (HxWxL): 23 ⁄4" x 9 "x 16 ⁄4" 591 x 229 x 413 mm Air Valve Required: 3-Way** ** Air consumption @ 100 psi is .15 CFM per stroke. Note: Check compatibility when using synthetic oils. Model 1826 Consists of Model 2002 PowerMaster pump, Model 85217 vent valve assembly, Model 81675 drum cover, Model 85209 controller, air and lubricant connecting hoses and 1200 psi (82 bar) safety unloader. Model: 1826 Lubricant/Air Ratio: 24:1 Output @ 75 Cycles/Min: 462 cu. in. 7571 cc Drum Size: U.S. standard 55-gal. refinery drum (removable head) 3 Air Inlet: ⁄8" NPTF (F) 3 Lube Outlet: ⁄4" NPTF (F) Typical System Min. 750 psig 52 bar Operating Pressure: Max. 1000 psig 69 bar Controller Electrical Requirements: 120 V 60 Hz, 110V 50 Hz Notes: 1. See System Controls section for detailed controller specifications. 2. See Industrial Pumping catalog for basic pump specification, including air consumption. Electric–Operated Oil Pump Model 1848 Fully automatic assembly including pump, 220-/440-volt motor, translucent reservoir, 1200 psi (82 bar) safety unloader, adjustable pressure switch and time control. Time control is adjustable for lubrication cycle frequency of 5, 10, 15, 20, 30 or 60 minutes. Solid state time delay relay (35 sec. to 240 sec.) included for connection of audible or visual alarm to signal lubrication failure due to empty reservoir or broken supply line. Model: 1848 Output/Min: 18 cu. in. 295 cc Reservoir Capacity: 14.7 pint 6.96 liter 424 cu. in. 6960cc 1 Lube Outlet: ⁄4" NPTF (F) Electrical Specifications: Pump Motor 220/440 VAC, 60 Hz, 3 ph Controller Max.. 115 VAC, 60 Hz Typical System Min. 750 psig 52 bar Operating Pressure: Max. 1000 psig 69 bar 3 13 Dimensions (HxWxL): 25 ⁄8" x 13 "x 19 ⁄16" 645 x 330 x 503 mm Note: See Model 85520, System Controls section for controller specifications. 30 ® Centro-Matic Automated Lubrication Systems Bucket Pumps Lincoln offers 60, 90 or 120 lb. reservoirs for our bucket pumps. Here are the features: • Rugged 14-gauge steel walls 3 • Large ⁄4" NPT inlet for fast filling • Wiper on follower plate that reduces lubricant waste • Special coupling for easy pump removal when servicing • Thick mounting ring that withstands severe vibration These buckets work with hydraulic, air and electric pumps. Enhanced low-level Eight bolts to resist indicator eliminates lid loosening false low level signals Weld nuts for easy lid Special coupling to removal easily remove the pump 14-gauge steel wall from the vent valve reduces denting and before servicing follower plate hang-up Thick rubber seal to keep contaminants out Tube to center of reservoir Aircraft cable to strengthen to prevent cocking connection between low-level and follower plate 3 Large ⁄4" NPT fill inlet Wiper on follower plate for faster filling to better wipe off the grease from the sides Stop bolts on Thick mounting ring with follower plate to twice as many mounting prevent cocking holes to resist loosening Model 84050 A 50:1 ratio double acting air-operated pump for high-volume displacement. Supplied with a 60-pound capacity metal reservoir with removable cover for easy filling. Includes air-operated vent valve and 5' (1.5m) air and lubricant connecting hoses. Model: 84050 Lubricant/Air Ratio: 50:1 Output/Min @ 100 PSIG Air: 30 cu. in. 492 cc Reservoir Capacity: 60 lb. / 27 kg 1800 cu. in. / 29,500 cc 3 Air Inlet: ⁄8" NPTF (F) 3 Lube Outlet: ⁄4" NPTF (M) at Hose Typical System Min. 1200 psig 82 bar Operating Pressure: Max. 3500 psig 241 bar 3 7 9 Dimensions (HxWxL): 31 ⁄4" x 15 ⁄16 "x 15 ⁄16" 806 x 392 x 395 mm Filling Method: Bulk Reservoir: Steel Notes: 1. Pump requires 3-way air valve. 2. Air consumption @ 100 psi is .42 CFM per cycle 3. Optional Model 92597 follower available. Model 85460 Same as Model 84050 except includes installed visual low level and follower plate assembly. 31 ® Centro-Matic Automated Lubrication Systems ® FlowMaster Hydraulic Pump High-performance FlowMaster hydraulic pumps combine rotary-driven pump motors with reciprocating pump tubes and flexible control features that perform in desert heat and arctic cold. Integrated control manifold adjusts the amount of lubricant and operating pressure. The pump’s output is adjustable from 7 to 45 cubic inches per minute. Supply Inlet Hydraulic Pressure, Max.: 3000 psig 200 bar Operating Inlet Hydraulic Pressure: 300 to 420 psig 20 to 32 bar Hydraulic Inlet Flow: Up to 7 gpm 28 l/min Pump Ratio with Manifold: 9:1 at low inlet pressure (300 to 350 psi/20 to 25 bar) and low inlet flow (below 2 gpm/7 lpm) 1/2" pump ratio approaches 11:1 ratio at higher inlet pressure and flow NPT 3 Pump Output: 7 - 45 in /min Operating Temperature: -20° to +150°F -10° to +65°C Solenoid Valve Coil: 24 VDC Hydraulic Inlet Port: SAE 4 Tank Return Port: SAE 6 1 Pump Outlets: ⁄4" NPTF 3/4" NPT Max. Hydraulic Fluid Temp: 200°F 93°C For the complete system, when ordering Pump Only Models 120# or 400# versions also order the following: Capacity Solenoid Adjustable Adjustable Model lbs gal L Manual Override Flow Control Pressure Control 120# Drum Cover 84616 Follower Assy 85492 85247 120 18 68 Yes Vent Valve Assy 84990 85480 120 18 68 400# Drum Cover 271606 85481 60 8 30 Follower Assy 270982 Vent Valve Assy 271605 85482 400 55 208 85483 35 5 19 No Yes Yes 85486 35 5 19 85586* 400 55 208 85610** 400 55 208 85676 90 10 38 Yes Fixed Fixed 85678 60 8 30 86261*** 35 5 19 No Yes Yes *Heavy-duty model **Low temperature model (-60°F) ***Kit consisting of pump, follower, bucket cover and hardware Pump & Bucket Models with follower plate and low-level detect Size Solenoid Adjustable Adjustable Model lbs gal L Manual Override Flow Control Pressure Control 85220* 120 18 68 No 85244** 90 10 38 Yes Yes Yes 85487** 60 8 30 No 85585 90 10 38 85677** 90 10 38 Yes Fixed Fixed 86258 60 8 30 No Yes Yes *Includes high-level detect **Does not include follower plate or low-level detect 19.517 9.08 11.46 (291) (231) Container Pump - in. (mm) Pump Bucket-in. (mm) Pressure 4.61 9.54 (242) Gage Size AB A B (117) 13.69 23.50 14.59 24.40 35 lb. (348) (597) (371) (620) 3/8 NPTF 3/8 NPTF Inlet Port 19.00 28.81 19.90 29.70 Tank Port 60 lb. (483) (732) (505) (754) 1/4 NPTF Pump B B 27.50 37.31 28.40 40.13 Outlets A 90 lb. (699) (942) (721) (1,019) A 27.50 37.31 28.40 40.13 120 lb. (699) (942) (721) (1,019) 34.00 43.81 34.00 44.94 400 lb. (864) (1,113) (864) (1,142) 15.090 1.25 (32) 32 ® Centro-Matic Automated Lubrication Systems ® FlowMaster Electric Pumps It seems too good to be true, but Lincoln’s new Electric FlowMaster Pump can serve all but the largest automated lubrication applications. Now you can take advantage of the ease and economy of this efficient, versatile electric pump—no cost for air associated with running the pump and no hydraulic hoses to connect. The Electric FlowMaster Pump is a workhorse. Because you can adjust the speed of the pump’s motor, you can adjust the pump’s output to precisely fit any application. Lincoln offers 12 different models. For manual lubrication, use the pump with a hose reel and a dispensing valve. ® 24 VDC FlowMaster Operating Temperature Range: -40° to +150°F -40° to +65°C 1 Pump Outlets: ⁄4" NPTF 1 Motor: ⁄2" HP PEAK Pump Only Models Capacity Maximum Speed Range Model lbs gal L Power Pressure Rating RPM 85479 35 5 19 2500 psi (170 bar) 9.5-100 85552 35 5 19 5-50 85553 120 18 68 85554 60 8 30 9-93 24 DC 5000 psi (345 bar) 85566 120 18 68 85567 60 8 30 36-360 85568 120 18 68 85569 35 5 19 2500 psi (170 bar) 9.5-100 85591 400 55 208 24 DC 5000 psi (345 bar) 36-360 85582 60 8 30 12 DC 3500 psi (241 bar) 300 3 Gear Current Draw Output: in /min Model Ratio Amps Min Max 5.84 85479* 17.8:1 2-5 0.7 6.3 (148) 85552 34:1 1-4.2 0.4 3.5 85553 2.95 (75) 85554 19:1 1-6.5 0.7 6.3 Power 85566 Wires Speed Control 85567 5:1 2-15 2.8 25.2 Potentiometer 85568 1/4 NPTF 85569 17.8:1 2-5 0.7 6.3 Pump Outlets 85582 31 21 both sides * Kit consisting of pump, follower, bucket cover and hardware Pump and Bucket Models 8.97 Capacity Maximum Speed Range (228) Model lbs gal L Power Pressure Rating RPM 85471 60 8 30 6.82 (173) 85472 90 10 38 24 DC 5000 psi (345 bar) 36-360 85473* 120 18 68 2.26 3 (57) Gear Current Draw Output: in /min Model Ratio Amps Min Max 85471 85472 5:1 2-15 2.8 25.2 85473 Above models include follower plate and low-level detect * Includes high-level detect 24 VDC Accessories Description 120 lb. 400 lb. Electric Vent Valve Follower plate 85492 270982 IP 67 Explosion 274899 Drum cover 85474 85475 Proof Rating Vent valve assembly: 24 VDC 85664 85665 IP 54 Explosion 525-32083-1 Proof Rating Strainer 272180 272180 33 ® Centro-Matic Automated Lubrication Systems ® FlowMaster Electric Pumps ® 120/230 VAC FlowMaster Now you can save the cost of air and plug in our new 120/230 VAC FlowMaster pump. Convenient and powerful, the 120/230 VAC FlowMaster pump allows you to tap into your AC power source and pump grease from a 120 lb. or 400 lb. drum. ® Rely on it to drive your automated lubrication systems such as Centro-Matic , ® ® Mod Lube , Quicklub and Two-line. Operating Temperature Range: -40° to +150°F (-40° to +65°C) Operating Voltage: 120/230 VAC (60 Hz only) 1 Pump Outlets: ⁄4" NPTF 1 Motor: ⁄2 HP Pump Only Models Capacity Maximum Speed Range Model lbs gal L Power Pressure Rating RPM 85588 400 55 208 120-230 AC 5000 psi (345 bar) 360 85589 120 18 68 3 Gear Current Draw: Amps Output: in /min Model Ratio @120 V @230 V Min Max 85588 5:1 1-4.6 .5-2.4 24.5 24.5 85589 Accessories Description 120 lb. 400 lb. Follower plate 85492 270982 Drum cover 85474 85475 Vent valve assembly: 120 VAC 85662 85663 230 VAC 85660 85661 Strainer 272180 272180 Reel-N-Flow Pump and Reel Kit Operating Temperature -20° to +140°F (-29° to +60°C) Operating Voltage 24 VDC (18 min., 30 max.) Motor 1/3 HP (0.25 kw) Max. Current Draw 15 AMPS 3 3 Max. Output 18.0 in /min (295 (cm /min) Max. Output Pressure 6,000 psi (413.8 bar) Pump Weight 35 lbs. kg (15.9) Hose Reel Capacity 3/8" High Pressure Hose, 50 ft. (15 m) Mounts on 35#/5-gallon refinery container Pump Models Model Description 274873 Bare, high-pressure pump 274874 Bare pump with integrated pressure switch and manifold Accessories Kit Models Description Model No. Bare Connect- Control Vlv. Model Description Lid Follower Reel Pump ing Hose & Swivel 10,000 psi Gauge 274872 274874 with bucket lid 35#/5-gal. 274886 274874 274878 274888 274934 and follower Container Mount 274886 with hose reel, 3050, 274887 50' hose,control valve, 274874 274878 274888 94553H 75084 81729 swivel & 7'connecting hose 34 ® Centro-Matic Automated Lubrication Systems ® FlowMaster Electric Pumps 50Hz 380/420V 3 Phase AC FlowMaster Pump The high-performance FlowMaster product line is a new generation of pump tech- nology. Compact and versatile, its unique rotary drive and modular gear set let you adjust the pump to exactly fit your application. • Wires directly to existing AC service • Reduces installation costs – no need to tap into hydraulic circuits or pipe in compressed air • Integrates easily to many styles of lubrication systems Markets include: • Heavy industry • General Industry – Mining – Food/beverage – Steel – Automotive – Paper – Packaging – And others Pump Model 85850 85851 Pump/Container Size 120 lb. 400 lb. 3 3 Pump Output 400 cm /min. (24.5 in /min. Operating Temperature -40° to 65°C (-40° to 150°F) Motor Max. Temperature Up to 105°C (220°F) Operating Voltage 380/420 Volts 3 Phase Motor Power 1/2 Hp Pump Outlet 1/4" NPTF Accessories Description 120 lb. 400 lb. Follower plate 85492 270982 Drum cover 85474 85474 Vent valve assembly 85660 85661 Strainer 272180 272180 35 ® Centro-Matic Automated Lubrication Systems Hydraulic-Powered Grease Pumps Model 84944 Hydraulic-operated pump with 60 lb. metal reservoir and vent valve. Model: 84944 Nominal Lubricant/ Hydraulic Pressure Ratio: 16:1 Output/Min @ 30 Cycles/Min: 11 cu. in. 180 cc Reservoir Capacity: 60 lb. / 27 kg 1800 cu. in. / 29,500 cc 1 Hydraulic Inlet/Outlet: ⁄4" NPTF (M) 3 Lube Outlet: ⁄4" NPTF (M) Important Note: 1. Pumps require a timed electrical signal to operate. Use Model 244270 Cycle Timer. See System Controls section for specifications. 2. Included hydraulic solenoids require 24 VDC. Model 84961 Basic pump only for Model 84944. Includes pump and hydraulic control. Does not include reservoir or vent valve. Model 84944 Model 84960 Hydraulic pump for use with U.S. standard 120 lb. refinery drum. System components (pump, vent assembly, drum cover and follower plate) must be ordered separately. Model 84962 Hydraulic pump for custom lubricant container installations. Pump length is sized for U.S. standard 400 lb. refinery drum depth. Nominal Lubricant/ Output/Min Lube Pump Tube Pump Tube Model Hydraulic Pressure Ratio @ 30 Cycles/Min Outlet Length Diameter 84960 —— 3 3 1 16:1 11 in / 180 cm ⁄4" NPTF(F) 15 33 ⁄16" 1" 84962 862 mm 25.4 mm Important Note: Model 84960 1. Pumps require a timed electrical signal to operate. Use Model 244270 Cycle Timer. See System Controls section for specifications. 2. Included hydraulic solenoids require 24 VDC. Use Vent Assembly Model 84990; Drum Cover Model 84616 and Follower Plate Model 83371. Drum Cover and Follower Plate are for use with Model 84960 only. Hydraulic Power Supply Requirements Hydraulic Inlet Flow Rate Fluid Max. Ambient Operating Pressure Inlet Filtration @ 30 Cycles/Min. Temperature Range psig / bar Temperature Requirement Min Max GPM ltrs/min Min Max 300 / 21 3000 / 207 1.0 / 3.8 210°F/99°C -40°F/-40°C +135°F/57°C 10 Micron Note: All pumps have a hydraulic pressure reducing valve rated for 60 psi (4 bar) to 800 psi (55 bar) output. Maximum input is 3000 psi (207 bar). Model 84962 36 ® Centro-Matic Automated Lubrication Systems Airless Spray System Airless Spray High-Pressure System No air required—three words describe why Lincoln’s innovative new Airless Spray System is the only system of its kind on the market. But it takes many more words to list all the benefits the latest in Lincoln’s long line of technological advances has to offer. Because no air is required, the Airless Spray System means that mining, concrete, steel and other heavy industries can look forward to dependable, high-pressure lubricant spraying that’s low-maintenance and cost-effective. 85418 Airless Spray Valve Model Operating Voltage Solenoid Valve Initial Current Heater Current Model 85418 85418 115 VAC .18 Amps 1.80 Amps Spray Tips Std Spray Std Tip with Roto-Clean Roto-Clean Tip Model Descrip. Tip Swivel Tip with Swivel* 252790 Retaining Nut Required Not Required Not Required Not Required 252792 Jet Stabilizer Optional Optional Optional Optional 85423-xxxxx ** Std. Spray Tip Required Required Not Required Not Required 271579 Swivel Assy Optional Required Optional Required 252831 Body Not Required Not Required Required Required 85427-xxxxx ** Roto-Clean Tip Not Required Not Required Required Required Controller * Discard tip retaining nut and protective cover, supplied with swivel assembly, when installing the roto-clean tip on a swivel assembly. ** See chart below for spray tip models Standard Carbide Spray Tips Roto-Clean Carbide Spray Tips Model Model Model Model 85423-5001 85423-11003 85427-5001 85427-9501 85423-6501 85423-11004 85427-6501 85427-9502 85423-6502 85423-650067 85427-6502 85427-650067 85423-8001 85423-800067 85427-8001 85427-800067 85423-8002 85423-950080 85427-8002 85427-1100067 85423-9501 85423-1100067 85423-9502 85423-1100080 85423-11001 Pumps Lincoln offers many pump options for supplying lubricant to the lube system. Air-operated pumps are preferred when possible due to their versatility and wide range of selection. Hydraulic and electric pumps are also available. The pump must be capable of pumping the lubricant to a minimum of 3500 psi at the airless spray valve. Filters Model Description Dual filter panel with operator valve to select one of the two filters. The other filter 85419 is isolated from the system pressure for uninterrupted service and easy element Model 85419 replacement 84111 High-pressure, single in-line filter (recommended) 84004 Single in-line filter Model 84111 37 ® Centro-Matic Automated Lubrication Systems Airless Spray System Controllers Control Wiring Harness Assembly Pumps Filters Airless Spray Valve Spray Tips High-Pressure Grease Supply Line Controllers Model Description For single and dual Airless systems. Operates system by setting the time between 254120 lubrication events. Includes manual lube button and system alarm. For single Airless system with external initiate contacts with manual lube button 256228 and system alarm For dual Airless system with external initiate contacts with manual lube button 254815 and system alarm Control Wiring Harness Assembly Model Description 25' wiring harness connects the controller to each spray valve. 256241 One wiring assembly is required for each spray valve. High Pressure Grease Supply Line To be furnished by installer 2-Way Fluid Solenoid Valve Model Description For multiple machine/single pump applications. See design guide (form #403172) 272285 for details. 38 ® Centro-Matic Automated Lubrication Systems Pump Accessories Reservoir Low-Level Alarm Kits Low-level kits signal need to fill reservoir. Lubricant Use with Switch Switch Capacity Model Features Type Models Type Voltage (Amps) 82653, 82655, 83668, 83800, 83834, 83167 83671 Grease 83599, 1833, 1835, 1849 125 VAC (15) 85434, 85435, 85436 250 VAC (15) Connect to machine 85437, 85444, 85445 480 VAC (15) control or visual/audible alarm circuit. SPDT 24 VDC (2) 82570, 82573, 83667, 1 125 VDC ( ⁄2) 83696 Oil 283167, 1848, 85430 1 250 VDC ( ⁄4) 85431, 85440,85441 Includes follower for 84629 Grease 84960 U.S. Std. 120 lb. drum. 85490 Grease 84050 Includes follower, visual None — indication only. 249608 Grease 84050 new style Follower Plates Recommended when pumping lubricants that do not readily seek their own level. Model Use with Pump Models Container Size 83370 1827, 1829 Standard U.S. 400 lb. refinery drum 83371 1823, 282288, 84960 Standard U.S. 120 lb. refinery drum 92544 1828, 1830 Standard U.S. 120 lb. refinery drum 92597 84050, 84944 Lincoln 60 lb. container 252725 85483 Lincoln 35 lb. unit 85489 85481 Lincoln 60 lb. unit In-Line Lubricant Filters Filters mount in pump outlet before vent valve on reciprocating pump systems. Removes solid contaminants before delivering lubricants to the supply line. Part Element Size Maximum Connections Hex Body No. micron Pressure in. Size - in. 1 1 84004 140 5000 psig / 340 bar ⁄2 NPTF (M) ⁄4 84528 420 1 1 *84239 10 6000 psig / 408 bar ⁄4 NPTF (F) 1 ⁄4 Model 84004, 84523 ® * In-line filter with Viton seal. Automatic Filling System Pressure Regulator Pressurized systems automatically keep up to eight, single stroke oil pump reservoirs full at all times. Use with reservoir seal kits below. Fill pump not included. Fill Pump Fill System Requirements Lubricant Vent Requirements Reservoir Max. Length Model Max. * Max. Pressure Inlet/Outlet Outlet 5 3 psig / bar Ratio ⁄8" Tube ⁄8" Tube psig / bar 1 1 83372 125 / 8.6 3:1 100'/ 30.5m 55'/16.8m 5 /.34 ⁄2" NPT(F) ⁄4" NPTF(F) * Indicates maximum lubricant output pressure. Pressure Kits Seal reservoirs for automatic filling. Model Use with Pump Models 83368 82885 83637 82570, 82573 39 ® Centro-Matic Automated Lubrication Systems Pump Accessories Manual Filling Pumps Designed to provide a fast, clean method of filling Centro-Matic pumps with a self-contained reservoir without the risk of lubricant contamination. Dimensions - in. / mm Lubricant Lubricant Container Hose Lubricant Container Model Height Width Type Output Capacity Length Outlet Diameter Grease 1 oz/stroke 645006 30 lbs. 7' Hydraulic 81834 NLGI #1 1.9 cu. in. 3 14.2 L 2.1 m Coupler Max 31 cc 26 ⁄4 14 9 1 pint/ 80599 679 356 229 30 pints 5' 1254 Oil 7 strokes Non-Drip 14.2 L 1.5 m 473 cc Nozzle Metal Reservoirs: Rectangular reservoirs for gravity feed oil pumps Standard ³⁄₈" NPTF outlet furnished for gravity-fed pumps. Features spring loaded cap with strainer, sight gauge and Buna-N O-rings. Model 84376 Sight Gauge Kit available for use with synthetic oil. Dimensions Capacity Lubricant Model Height Width Depth Outlet Gal Liter in mm in mm in mm 1 1 87417 5 19 17 ⁄2 446 12 ⁄2 318 3 1 1 1 87418 3 11.4 ⁄8" NPTF (F) 10 ⁄8 257 13 ⁄2 343 11 ⁄2 292 1 1 87419 1.5 5.7 10 ⁄2 267 7 ⁄2 191 Cylindrical Reservoir Four-gallon steel tank-type reservoir consisting of Model 82700 tank and Model 82612 mounting brackets. Incorporates large filler opening with screw cap. Tank Bracket Lubricant Dimensions - in. / mm Model Capacity Number Number Outlet Height Diameter 82621 82700 82612 4 gal./15.1L ¹⁄₂" NPT (F) 18 / 457 9 / 229 Ultrasonic Sensor ® Ultrasonic High/Low Sensor to make it easier to know when the 60 lb. Centro-Matic automated lubrication system reservoir is getting low on lubricant and when it’s refilled to capacity. Sensor detects the position of the follower plate with ultrasonic waves to report the lubricant level. The sensor is factory programmed for a 60 lb. reservoir. Its two outputs drive external signaling devices or connect with a customer’s PLC. Three standard LEDs offer visual indication of the sensor’s sensor status and reservoir level. Model Description 270782 Ultrasonic sensor 270781 Ultrasonic sensor socket (required) Ambient Protection Power Supply Current Switching Outputs Temp. Range Operating Range less load Max. Current High Level Low Level NO contact NO contact -13°F to 158°F IP65 20 - 30 VDC 60 mA 200 mA (closes (opens -25°C to 70°C when full) when low) 40 ® Centro-Matic Automated Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the degree of automation and monitoring required. Your Lincoln representative will assist you in specifying the correct model. Options range from simple timers to fully-automated system controllers and monitors. Basic timers allow you to set the interval between lubrication cycles. More sophisticated monitors control the frequency of lubrication, oversee system performance and can sense lubricant flow to each bearing while showing system status and alarms on a LCD display panel. Monitors may be interfaced with machine control systems to protect your equipment from harm. You may customize your installation with air and lubricant filters to prolong system life, pressure gauges for monitoring, shut-off valves to ease future maintenance and even automated filling systems to utilize bulk lubricant storage. All of these possibilities, and more, have made Lincoln Automated Lubrication Systems the choice of industry for over 80 years. Model 84501 Program Timer—Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid valve (not included) installed in the air line to pump. Off Time On Time Power Switch (Cycle Time) (Pumping Time) Approvals Requirements Capacity Min Max Min Max 1 Min. 120/230 VAC 120 VAC, 5 Amps 20 Sec. 24 Hrs. 10 Sec. UL, CSA 24 Sec. 50/60 Hz 230 VAC, 1.5 Amps Ambient Operating Built-In Program Options Enclosure Temperature Range 3 Hr. Program Prelube Dimensions-in./mm Rating Minimum Maximum Memory Function Height Width Depth 8¹⁄₄ 6¹³⁄₁₆ 4¹⁵⁄₁₆ 0°F 130°F Yes No Yes No NEMA #1 210 173 125 -18°C 54°C Note: Refer to Technical Manual for a full explanation of available program options. Model 84511 Economy Timer for Single Stroke Pumps Uses a timing motor, cam and switch to turn pump off and on. NEMA 1 enclosure, UL and CSA listed. Switch capacity 10 amps non-inductive. Off Time On Time Power Switch (Cycle Time) (Pumping Time) Approvals Requirements Capacity Min Max Min Max 5 Min. 1 Hr. 30 Sec. 90 Sec. 120 VAC, 60 Hz UL, CSA 10 Amps Note: Off-time selectable in 5 minute intervals. Enclosure Dimensions - in. / mm Rating Height Width Depth NEMA 1 5 / 127 3¹⁄₄ / 82.5 3¹⁄₂ / 89 41 ® Centro-Matic Automated Lubrication Systems System Controls Model 84015 Timer—12-24V DC Solid-state microprocessor-based controller for automated lubrication systems on mobile equipment or where AC power is not available. Rugged construction with liquid- and dust-tight enclosure. Includes manual push-button for remote initiation of a lube cycle. Off Time** Fixed On Time Power Switch (Cycle Time) (Pumping Time) Requirements Capacity Min. Max. 10-30 VDC 2.5 Min. 80 Min. 75 Sec. 5 Amps 25 MA* * Less load. ** Available selections are 2.5, 5, 10, 20, 40 or 80 minutes. Enclosure Ambient Operating Temperature Range Dimensions-in. / mm Rating Minimum Maximum Height Width Depth NEMA 12 5¹⁄₄ / 133 3¹⁄₈ / 79 3 / 76 0°F / -18°C 131°F / 55°C Model 85520 Programmable Controller Microprocessor-controlled, 120 volt AC unit is fully programmable. Controller has a wider off-time range than timers and a memory switch to turn pre-lube option on or off. Off Time On Time (Pumping/ Switch Capacity Power (Cycle Time) Alarm Time) Inductive Load at 120VAC Requirements Min. Max. Min. Max. Load Relay Alarm Relay 30 300 120 VAC 2 2 30 Sec. 30 Hours Sec. Sec. 50/60 Hz Amps Amps Enclosure Ambient Operating Temperature Range Dimensions-in. / mm Rating Minimum Maximum Height Width Depth NEMA 12 7¹⁄₂ / 191 4¹⁵⁄₁₆ / 125 3¹⁄₂ / 89 0°F / -18°C 130°F / 55°C * Less load. Model 85525 Programmable Controller Same as Model 85520 except includes pressure switch and mounting brackets. Model 85535 System Controller—24V DC Same as Model 85520 except is a 24-volt DC. 42 ® Centro-Matic Automated Lubrication Systems System Controls Model 85530 Lubrication System Controller Controls lubrication frequency and monitors supply line pressure. The LCD displays operating status. Lube Cycle Max. Pumping Time Timer Mode Counter Mode Count Before Alarm Off-Time Off-Counts Rate* Min. Max. Min. Max. Min. Max. 30/Sec. 1. 9,900 1 99,000 1 99 @ 50% Minute Minutes Count Counts Minute Minutes DutyCycle * Minimum duration of count signal is 33 milliseconds. Power Requirements (less load) Pump, Ambient Enclosure Solenoid, Temperature Dimensions-in. / mm Rating Voltage Current or Alarm Range Height Width Depth Capacity 120 VAC, 50/60 Hz 85 MA 360 VA 32° to 122°F NEMA 9¹⁄₂ 8¹⁵⁄₁₆ 4¹⁄₈ 230 VAC, 50/60 HZ 45 MA 0° 12 241 227 105 to +50° C 24 VDC 250 MA 5 Amps Note: Model 85530 is CSA/NRTL approved. Model 85209 Panel Mounted Pneumatic Control System Panel mounted units control lubrication frequency and monitor supply line pressure. Includes Model 85530 Controller (specifications above), Model 69630 Pressure Switch and solenoid-operated air valve. Lube Cycle Pumping Timer Counter Max. Time Mode Mode Count Before Connections Off Time Off Counts Rate Alarm Min. Max. Min. Max. Min. Max. Air Lube 1 9,900 1 99,000 30/ 1 99 ³⁄₈" ³⁄₄" Minute Minutes Count Counts Sec. Minute Minutes NPTF(F) NPTF(F) Power Requirements External Ambient Panel Current Alarm Temperature Dimensions Voltage (less load) Load Range in. / mm Capacity Height Width 120 VAC, 60 Hz 32° to 122°F 12 18¹⁄₄ 47 VA 360 VA 110 VAC, 50 Hz 0° to +50°C 305 464 Model 85208 Same as Model 85209 except 220 VAC, 50-60 Hz power. 43 ® Centro-Matic Automated Lubrication Systems System Controls Model 85500 System Sentry II The ultimate automated lubrication system controller/monitor now features greater monitoring accuracy with less sensitivity to lubricant flow rates, feed line length, or bearing back pressure. System Sentry II is always on the job, making sure that every lube point is lubricated when it’s supposed to be. • Solid-state controller with LCD status display and 16-button keypad for system programming • Controls up to two pumps with as many as two lube zones per pump • Fully programmable monitoring and alarm functions • Be set up to monitor every lube point for lubricant flow during each lubrication event • Easy to understand prompts reported by simple English language messages in real time Some functions require optional accessories. Use a maximum of 48 sensors and three accessory Sensor Boards (order separately—16 sensors per board) to monitor lube points. Lube Cycle Max. Pumping Time Timer Mode Counter Mode Count Before Alarm Off-Time Off-Counts Net Rate* Min. Max. Min. Max. Min. Max. Wt. 30/Sec. 1 9,900 1 99,000 1 99 18 lbs. @ 50% Second Minutes Count Counts Second Minutes 8.1 kg Duty Cycle * Minimum duration of count signal is 33 milliseconds. Power Requirements (less load) Pump, Ambient Enclosure Solenoid, Temperature Dimensions-in. / mm Voltage Current or Alarm Range Rating Height Width Depth Capacity 120 VAC, 50/60 Hz 250 MA* 360 VA 32° to 122°F NEMA 11 14 4⁷⁄₈ 230 VAC, 50/60 HZ 125 MA* ° 12 241 227 105 0 to +50° C 24 VDC 600 MA* 5 Amps Note: Model 85500 is CSA/NRTL approved. * No external load, no sensors. 44 ® Centro-Matic Automated Lubrication Systems System Controls Model 247333 Pressure Transducer Pressure Transducer signals actual system pressure via LCD display of System Sentry II. Comes with 72 inch (1.8m) shielded 24-gauge connecting wire. Maximum length of wire between transducer and monitor is 30 (9.1m) feet. Pressure Ambient Voltage Range Accuracy Proof Enclosure Connection Temp. Input Output Offset NEMA 4X 0 to 7500 psig ¹⁄₄" NPT -20° to 180° F 10 to 1-6 1 Rating ±1% 4000 psi 517 bar Male Thread -29° to 82° C 30 VDC VDC 300 Series 276 bar VDC Stainless Steel Model 250365 Sensor Board Plug-in accessory board used with Model 85500 that allows the attachment of up to 16 lube flow sensors. (Model 85500 comes without boards installed and can hold up to a total of three.) Sensor Assemblies Sensor assemblies consist of a check body and lube sensor with attached 30' cable. Cables are epoxy potted into the sensors for a watertight seal. Sensors 3 ® have a ⁄8" pipe thread for conduit connection and a Viton O-ring seal. Check 1 bodies terminate in a ⁄8" NPTF male thread for attachment to a bearing or other lubricant inlet. Maximum working pressure 6,000 psi (414 bar). Maximum wire run from sensor to monitor is 500 feet (152m). Min. Interval Lubricant Min. Flow Inlet/ Model Description Construction Between Lube Temp. Range Per Event Outlet Flow Event Straight Sensor 250400 .004 cu.in./.066 cc Assembly Brass Sensor & Plated Steel @ 32°F / 0° C to 90° Sensor Check Body 250490 125°F / 52°C 32° to 145° F Assembly 1/8" 30 Seconds 0° to 63° C Straight Sensor 316 3 .008 in / .131cc 250500 Assembly Stainless Steel @ 126ºF / 53ºC to 90° Sensor Sensor & 145ºF / 63ºC 250590 Assembly Check Body Model 243100 Sensor Wire 100 foot (30.5 meters) coil of two conductor 22-gauge wire for connecting sensors to monitor. Maximum length of wire between sensor and monitor is 500 feet (152 meters). 45 ® Centro-Matic Automated Lubrication Systems System Controls Use This Guide to Select Accessories for Model 85500 System Sentry II Pressure Pressure Sensor Sensor Wire Function Switch Transducer Board Sensors #243100 (100') Note 2 Note 3 #69630 #247333 #250365 Lube Controller 1 Pump, 1 Zone Optional 1 Optional 1 —— — Note 1 Lube Controller, Required 1 Pump, 1 per Zone Required 1 —— — Up to 3 Zones (3 Max.) Lube Controller, Required 2 2 Pumps, 1 Zone No (1 per Pump) —— — Per Pump Lube Controller, Required Required 2 2 Pumps, Up to 2 1 per Zone (1 per Pump) —— — Zones Per Pump (4 Max.) Lube Point Required Required Required Monitoring —— 1 per each 1 per Quantity ≤ 48 Points 16 Sensors Lube Point As Needed Note 1: Controller may be operated without a pressure switch or pressure transducer but will not be able to monitor and alarm for lube system pressure failures. Note 2: Sensors include 30' (9.1m) cable pigtail. Select brass/plated steel or stainless steel sensors in straight or 90° configuration as required. Note 3: Maximum distance between monitor and sensor is 500' (152 meters). 46 ® Centro-Matic Automated Lubrication Systems System Controls Electric Solenoid-Operated Air Valves Electrical Characteristics Power Inrush Holding Air Ambient Cv Max. Conduit Model Type Requirements Current Current Inlet/ Temperature Factor Pressure Connection Amps Amps Outlet Range psi / bar 110 VAC, 50 Hz 350244 120 VAC, 60 Hz .11 .07 8.4 VA 0° to 120°F 4-Way 1.2 220 VAC, 50 Hz -18° to 49°C 350245 240 VAC, 60 Hz .055 .035 8.4 VA 1 1 ⁄4" ⁄2" NPS(F) 110 VAC, 50 Hz NPT(F) 350241 120 VAC, 60 Hz .11 .07 8.4 VA 150 220 VAC, 50 Hz 10.3 350242 240 VAC, 60 Hz .055 .035 .18 3-Way 8.4 VA 12 VDC 0° to 140°F 350282 1 6 Watts ⁄8" -18° to 60°C N/A N/A N/A 24 VDC NPT(F) 350283 6 Watts 3 120V, 60 Hz ⁄8" 1 68586 2-Way .2 .1 2.4 ⁄2" NPT(F) NPT(F) 12 VA 1 24 VDC ⁄4" 274398 3-Way N/A N/A .5 N/A 8.5 Watts NPT(F) 3 110 VAC, 50 Hz ⁄8" 0° to 120°F 1 244727 3-Way 120 VAC, 60 Hz .12 .09 NPT(F) 4.4 ⁄2" NPT(F) -18° to 49°C 11 VA Model 249605 Sealed Cycle Timer Sealed timer attaches to Lincoln 16:1 Hydraulic Pumps and generates timed pulse signal to control pump reciprocating cycle rate. Cycle Rate/Minute Power Requirement Min. Max. 24 VDC 6 60 47 ® Centro-Matic Automated Lubrication Systems System Controls End-of-Line Monitors Designed to detect system pressure utilizing normally open or normally closed switch. Switch Operating Range - psig / bar Lube Dimensions - in / mm Conduit Model Rating Min. Max. Inlet Height Width Connection 125, 250 ¹⁄₄" 83898 1200 / 83 2500 / 172 480 VAC, NPTF(F) 5³⁄₄ / 146 2¹⁄₄ / 57 ¹⁄₂" NPSM 83899 700 / 48 1150 / 79 15 Amps Model 83354 Signal Monitor Designed to provide visual and audible indication of system operation and failure. Utilizes signal from system controller. Includes Model 69606 Alarm Horn mounted on enclosure door. Indicator Lamps Dimensions - in / mm Power Audible Power Lube System Requirement Height Width Depth Alarm On System On Failure 115 VAC 69606 Horn 10 86 50/60 Hz Green Amber Red (included) 254 203 152 35 VA Note: Lamps and horn are U.L. listed. Model 69630 Pressure Switch Senses supply line pressure rise/fall to signal system operation to controller or system alarm. Switch Capacity Adjustable Range - psig / bar Connections Type Decreasing Increasing AC DC Lube Electrical Min. Max. Min. Max. 15Amps@6VDC ²⁷⁄₃₂" hole 10 Amps at Single 5Amps @24VDC 250 2775 280 3000 for ¹⁄₂" 125, 250 or ¹⁄₄" NPT(F) Contact .03 Amps @ 17 191 19 207 conduit 480 VDC 250 VDC connector Note: Pressure switch has a NEMA 3 housing and UL listed switching elements. 48 ® Centro-Matic Automated Lubrication Systems Numerical Index ® ® Viton and Teflon are registered trademarks of DuPont Performance Elastomers Model No. Page No. Model No. Page No. P603S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 21 75084. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 P653S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 19 80072. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 525-32083-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 80073. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41110-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80074. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41110-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80075. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41119-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80076. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41062-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80077. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41062-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80078. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41062-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80079. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41062-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80080. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41062-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80081. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41064-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80082. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41064-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80083. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41064-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80084. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41064-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80085. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41064-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80086. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41064-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80087. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 645-41073-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 80088. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1254 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 80089. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1810 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 80090. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1812 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 80091. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1823 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26, 39 80105. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1826 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 80106. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1827 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26, 39 80107. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1828 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26, 39 80108. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1829 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26, 39 80109. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1830 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 80110. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1833 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27, 39 80111. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1835 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27, 39 80112. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1848 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30, 39 80599 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 1849 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27, 39 81646 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 81675 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 2008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 81713 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 81713A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 81729. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 12511 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 81770-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 12511-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 81770-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 12698 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 81770-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 12698-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 81770-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 14988 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 81770-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 14991 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 81770-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 66260 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 81834 . . . . . . . . . . . . . . . . . . . . . . 22, 24, 25, 27, 40 66260-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 82272 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 66713 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 82292. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 67007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 82294-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 67007-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 82294-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 67044 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 82294-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 68421 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 82294-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 68483 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 82294-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 68586 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 82295 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 68587 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 82570 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29, 39 68874 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 82573 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29, 39 69456 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 82612 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 69630 . . . . . . . . . . . . . . . . . . . . . . . . . 43, 46, 47, 48 82621 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 49 ® Centro-Matic Automated Lubrication Systems Numerical Index Model No. Page No. Model No. Page No. 82653 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 39 83715-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 82655 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 39 83724-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 82676 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 83724-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 82700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 83724-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 82885 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29, 39 83724-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 82886 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 83730 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 83167 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25, 39 83748 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 83272 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 83749-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 83309-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 83749-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 83309-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 83749-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 83309-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 83749-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 83309-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 83749-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 83309-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 83800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 39 83309-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 83817 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 83311-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83834 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 39 83311-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83898 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 83311-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83899 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 83311-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 83311-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83900-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 83311-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83924 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 83311-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83924-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 83311-15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 84004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37, 39 83313 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 84015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 83314 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 84034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 83314-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 84048 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83336-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 84050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31, 39 83336-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 84110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 83336-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 84111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 83336-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 84195 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 83337 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 84200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 83337-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 84203 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 83338 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 84204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 83354 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 84239 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 83368 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 84297 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 83370 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 84376 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 83371 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26, 36, 39 84428-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83372 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 84428-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83535 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 84428-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83599 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25, 39 84428-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83637 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 84428-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83661-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 84428-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83661-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 84428-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83661-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 84428-15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 83660 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 84429-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 83661-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 84429-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 83667 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29, 39 84429-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 83668 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 39 84429-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 83671 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 84501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 29, 41 83696 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 84511 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 83715-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 84528 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 83715-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 84616 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 36 83715-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 84629 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 83715-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 84776 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 83715-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 84944 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36, 39 50 ® Centro-Matic Automated Lubrication Systems Numerical Index Model No. Page No. Model No. Page No. 84960 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36, 39 85427-800067 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 84961 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 85427-1100067 . . . . . . . . . . . . . . . . . . . . . . . . . . 37 84962 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 85430 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28, 39 84990 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 36 85431 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28, 39 85208 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 85432 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 85209 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26, 30, 43 85433 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 85215 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 85434 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23, 39 85217 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 85435 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23, 39 85218 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 85436 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23, 39 85220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85437 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 85244 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85438 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 85247 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85440 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28, 39 85351-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28, 39 85351-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85442 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 85351-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85444 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23, 39 85351-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85445 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23, 39 85351-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85460 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 85351-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85471 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 85352-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85472 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 85352-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85473 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 85352-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85474 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 34, 35 85352-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85475 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 34 85352-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85480 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85352-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85481 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 39 85353-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85482 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85353-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85483 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 39 85353-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85486 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85353-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 85487 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85391 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 85489 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 85418 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85490 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 85419 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85492 . . . . . . . . . . . . . . . . . . . . . . . . . 32, 33, 34, 35 85423-5001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85497 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 85423-6501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44, 45, 46 85423-6502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85520 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27, 30, 42 85423-8001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85525 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 85423-8002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85530 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 85423-9501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85535 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 85423-9502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85585 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85423-11001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85586 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85423-11003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85588 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 85423-11004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85589 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 85423-650067 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85591. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 85423-800067 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85610 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85423-950080 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85660 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34, 35 85423-1100067 . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85661 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34, 35 85423-1100080 . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85662 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 85427-5001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85663 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 85427-6501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85664. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 85427-6502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85665. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 85427-8001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85676 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85427-8002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85677 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85427-9501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85678 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85427-9502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85770-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 85427-650067 . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85770-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 51 ® Centro-Matic Automated Lubrication Systems Numerical Index Model No. Page No. Model No. Page No. 85770-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 249605 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 85770-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 249608 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 85770-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 250365 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45, 46 85770-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 250400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 85771 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 250490 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 85772 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 250500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 85780-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 250590 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 85780-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 252725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 85780-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 252790 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85780-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 252792 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85780-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 252831 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85780-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 254120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 85781 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 254815 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 85782 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 256228 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 85785-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 256241 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 85785-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 270781 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 85785-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 270782 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 85785-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 270982 . . . . . . . . . . . . . . . . . . . . . . . . 32, 33, 34, 35 85785-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 271579 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 85785-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 271605 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85785-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 271606 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 85785-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 272180 . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 34, 35 85785-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 272285 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 85785-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 273088 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 85850. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 273089 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 85851. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 274398 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 86258 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 274824. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 86261 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 274886 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 87417 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 274887 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 87418 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 274872 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 87419 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 274873 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 90537 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 274874 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 92544 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 274878 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 92597 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31, 39 274888 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 94553H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 274934 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 102781 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 274899. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 239351 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 282288 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26, 39 239352 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 283167 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30, 39 239353 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 350241 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 239354 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 350242 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 239355 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 350244 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 29, 47 243100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45, 46 350245 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 244270 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 350282 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 244727 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 350283 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 247333 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45, 46 645006 . . . . . . . . . . . . . . . . . . . . . 22, 24, 25, 27, 40 249281 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16, 17 249282 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16, 17 52 A Complete Line of Lubrication Solutions and Industrial Pumping Products Our automated systems dispense measured amounts of lubricant at predetermined intervals. ® ® Systems include Helios and Duo-Matic two-line Automated Lubrication ® ® systems, Centro-Matic , Modular Lube and ® ® Quicklub as well as ORSCO precision oil lubrica- ® tion. With our BearingSaver program, we find the best automated solution for you from our wide range of systems for grease, fluid grease and oil. General Lubrication Lincoln has developed Industrial Pumping specialized pumps and Sometimes a simple pumping stations to approach is the best handle the difficult job of solution. Our wide range transferring thick fluids. From of products includes smaller, ® the industry-best PileDriver III self-contained automated ® and PowerMaster III pumps lubricators and general and air motors to specialty lubrication equipment. pumps, controls and mounting accessories, Lincoln is the preferred pumping system for many tough applications. Lincoln's Lincoln's g global lobal di dis st tr ri ibution bution ne net tw wo or rk k is is t the he be bes st t in t in the indu he indust stry ry. . Whatever the service—evaluating your lubrication methods, installing a custom-engineered system, or supplying top-quality manual lubrication products—your Lincoln distributor makes certain you always get the very best value. Systems House Distributors Our systems house distributors offer the highest level of expertise available in the industry. They can custom design a system with the exact combination of Lincoln components you need. Then, they install the system in your plant with their knowledgeable technicians or work with your personnel to make sure the job is done correctly. Each distributor stocks a full inventory of pumps, metering devices, controllers, monitors and accessories. Each continues to meet our stringent requirements for product, systems and service knowledge. From Los Angeles to London, Boston to Bangkok, Lincoln’s top-of-the- industry systems house distributors will be there when and where you need them. For the nearest authorized Lincoln sales and service representative, call: Americas: St. Louis, Missouri 314.679.4200 Fax: 800.424.5359 Europe/Africa: Walldorf, Germany 49.6227.33.0 Fax: 49.6227.33.259 Asia/Pacific: Singapore 65.6588.0188 Fax: 65.6588.3438 Lincoln Industrial Corp. Phone 314.679.4200 Form 442832 (09/09) One Lincoln Way Fax 314.679.4359 © Copyright 2009 St. Louis, MO 63120-1578 www.lincolnindustrial.com Printed in U.S.A.

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 3309-4 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products