KEPCO FAW
Features
- Low noise
- Operation indicator LED
- Rail mountable. Small open frame(cover is optional)
- Since input voltage can be selected over a range of AC.85 to 264V(AC.100 to 200V rating), these power supplies are compatible with industrial power voltages throughout the world
Datasheet
Extracted Text
FAW Series Power Supplies AC Input Single Output, General-Purpose FEATURES • Since input voltage can be selected over a range of AC.85 to 264V(AC.100 to 200V rating), these power supplies are compat- ible with industrial power voltages throughout the world. • Rail mountable. Small open frame(cover is optional). • Operation indicator LED. • Low noise. PART NUMBERS AND RATINGS 15W type 25W type 50W type Output voltage(V) Current(A) Part No. Current(A) Part No. Current(A) Part No. 5 3 FAW05-3R0 5 FAW05-5R0 10 FAW05-10R 12 1.3 FAW12-1R3 2.1 FAW12-2R1 4.2 FAW12-4R2 15 1 FAW15-1R0 1.7 FAW15-1R7 3.4 FAW15-3R4 24 0.7 FAW24-0R7 1.1 FAW24-1R1 2.1 FAW24-2R1 100W type 150W type Output voltage(V) Current(A) Part No. Current(A) Part No. 5 20 FAW05-20R 30 FAW05-30R 12 8.3 FAW12-8R3 12 FAW12-12R 15 6.6 FAW15-6R6 10 FAW15-10R 24 4.2 FAW24-4R2 6 FAW24-6R0 28 3.5 FAW28-3R5 5 FAW28-5R0 48 2 FAW48-2R0 2.8 FAW48-2R8 Specifications which provide more details for the proper and safe use of the described product are available upon request. All specifications are subject to change without notice. FAW Series Power Supplies AC Input Single Output, General-Purpose SPECIFICATIONS 15W TYPE Part No. FAW05-3R0 FAW12-1R3 FAW15-1R0 FAW24-0R7 1 Output voltage, current*5V • 3A 12V • 1.3A 15V • 1A 24V • 0.7A Maximum output power W 15 15.6 15 16.8 Input requirements Input voltage Eac V 85 to 264[Rating: 100-120, 200-240] Input frequency Hz 47 to 66[Single phase] Input current A 0.4max./0.3max.[100-120V/200-240V, at maximum output power] Fuse rating A 2[Internal] 2 Surge current*A 22max./34max.[100-120V/200-240V, 25°C, output rating, cold start] Leakage current mA 0.5max./0.75max.[100-120V/200-240V, 25°C, output rating] Efficiency % 70typ. Output characteristics Output voltage V 5 12 15 24 Voltage variable range V 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 1 Maximum output current*A 3 1.3 1 0.7 Overvoltage threshold V 6 to 6.9 13.7 to 15.7 17 to 19 27 to 30.5 Overcurrent threshold A 3.3 to 5.5 1.4 to 2.5 1.1 to 2 0.8 to 1.4 Input variation % 2max.(1typ.)[85 to 132V, 170 to 264V] Load variation % 2max.(1typ.)[10 to 100% load] Total variation 4max.(2typ.) Temperature Voltage stability % 2max.(1typ.)[0 to +50°C] variation Drift % 0.5max.(0.1typ.)[25°C, input and output ratings, after input voltage ON for 30min to 8h] Dynamic load %/ms ±4max./2max.[50 to 100% sudden load change] Ripple Ep-p mV 60max. 80max. 80max. 100max. Ripple noise Ep-p mV 120max. 190max. 220max. 310max. Start up time ms 500max. Hold up time ms 15min. Accessory equipment Operation indicator LED illuminates when voltage output is ON. Overvoltage protection Voltage shielding type, recovers upon reset after roughly 30s. Overcurrent protection Fixed current threshold type, automatic recovery. Remote ON-OFF None Remote sensing None Current balance None Standards Safety standards UL1950D3, CSA1402C, EN60950(TÜV) approved. Noise terminal voltage FCC class B[100-120V], VDE0871 class B[220-240V] compliant. Construction 3 External dimensions H·W·Lmm 25·95·100 With cover(Option)*: 30·95·100 Weight g 270max. Mounting method Can be attached to 2 sides. Case material Frame: Steel Cover(Option): Steel *1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range. *2 The surge current suppression element is a power thermistor. *3 Derating is required when the optional cover is attached. Specifications which provide more details for the proper and safe use of the described product are available upon request. All specifications are subject to change without notice. FAW Series Power Supplies AC Input Single Output, General-Purpose SPECIFICATIONS 25W TYPE Part No. FAW05-5R0 FAW12-2R1 FAW15-1R7 FAW24-1R1 1 Output voltage, current*5V • 5A 12V • 2.1A 15V • 1.7A 24V • 1.1A Maximum output power W 25 25.2 25.5 26.4 Input requirements Input voltage Eac V 85 to 264[Rating: 100-120, 200-240] Input frequency Hz 47 to 66[Single phase] Input current A 0.7max./0.45max.[100-120V/200-240V, at maximum output power] Fuse rating A 2.5[Internal] 2 Surge current*A 43max./85max.[100-120V/200-240V, 25°C, output rating, cold start] Leakage current mA 0.5max./0.75max.[100-120V/200-240V, 25°C, output rating] Efficiency % 70typ. Output characteristics Output voltage V 5 12 15 24 Voltage variable range V 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 1 Maximum output current*A 5 2.1 1.7 1.1 Overvoltage threshold V 6 to 6.9 13.7 to 15.7 17 to 19 27 to 30.5 Overcurrent threshold A 5.5 to 7.5 2.3 to 3.3 1.9 to 2.8 1.2 to 1.8 Input variation % 2max.(1typ.)[85 to 132V, 170 to 264V] Load variation % 2max.(1typ.)[10 to 100% load] Total variation 4max.(2typ.) Temperature Voltage stability % 2max.(1typ.)[0 to +50°C] variation Drift % 0.5max.(0.1typ.)[25°C, input and output ratings, after input voltage ON for 30min to 8h] Dynamic load %/ms ±4max./2max.[50 to 100% sudden load change] Ripple Ep-p mV 80max. 100max. 120max. 150max. Ripple noise Ep-p mV 120max. 190max. 220max. 310max. Start up time ms 500max. Hold up time ms 15min. Accessory equipment Operation indicator LED illuminates when voltage output is ON. Overvoltage protection Voltage shielding type, recovers upon reset after roughly 30s. Overcurrent protection Fixed current threshold type, automatic recovery. Remote ON-OFF None Remote sensing None Current balance None Standards Safety standards UL1950D3, CSA1402C, EN60950(TÜV) approved. Noise terminal voltage FCC class B[100 to 120V], VDE0871 class B[220 to 240V] compliant. Construction 3 External dimensions H·W·Lmm 25·95·125 With cover(Option)*: 30·95·125 Weight g 300max. Mounting method Can be attached to 2 sides. Case material Frame: Aluminum Cover(Option): Steel *1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range. *2 The surge current suppression element is a power thermistor. *3 Derating is required when the optional cover is attached. Specifications which provide more details for the proper and safe use of the described product are available upon request. All specifications are subject to change without notice. FAW Series Power Supplies AC Input Single Output, General-Purpose SPECIFICATIONS 50W TYPE Part No. FAW05-10R FAW12-4R2 FAW15-3R4 FAW24-2R1 1 Output voltage, current*5V • 10A 12V • 4.2A 15V • 3.4A 24V • 2.1A Maximum output power W 50 50.4 51 50.4 Input requirements Input voltage Eac V 85 to 264[Rating: 100-120, 200-240] Input frequency Hz 47 to 66[Single phase] Input current A 1.2max./0.7max.[100-120V/200-240V, at maximum output power] Fuse rating A 3[Internal] 2 Surge current*A 45max./90max.[100-120V/200-240V, 25°C, output rating, cold start] Leakage current mA 0.5max./0.75max.[100-120V/200-240V, 25°C, output rating] Efficiency % 76typ. Output characteristics Output voltage V 5 12 15 24 Voltage variable range V 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 1 Maximum output current*A 10 4.2 3.4 2.1 Overvoltage threshold V 6 to 6.9 13.7 to 15.7 17 to 19 27 to 30.5 Overcurrent threshold A 10.5 to 12 4.4 to 5.1 3.6 to 4.1 2.2 to 2.6 Input variation % 2max.(1typ.)[85 to 132V, 170 to 264V] Load variation % 2max.(1typ.)[10 to 100% load] Total variation 4max.(2typ.) Temperature Voltage stability % 2max.(1typ.)[0 to +50°C] variation Drift % 0.5max.(0.1typ.)[25°C, input and output ratings, after input voltage ON for 30min to 8h] Dynamic load %/ms ±4max./2max.[50 to 100% sudden load change] Ripple Ep-p mV 80max. 100max. 120max. 150max. Ripple noise Ep-p mV 120max. 190max. 220max. 310max. Start up time ms 500max. Hold up time ms 15min. Accessory equipment Operation indicator LED illuminates when voltage output is ON. Overvoltage protection Voltage shielding type, recovers upon reset after roughly 30s. Overcurrent protection Fixed current threshold type, automatic recovery. Remote ON-OFF None Remote sensing Yes Current balance None Standards Safety standards UL1950D3, CSA1402C, EN60950(TÜV) approved. Noise terminal voltage FCC class B[100 to 120V], VDE0871 class B[220 to 240V] compliant. Construction 3 External dimensions H·W·Lmm 25·95·165 With cover(Option)*: 31·95·165 Weight g 450max. Mounting method Can be attached to 2 sides. Case material Frame: Aluminum Cover(Option): Steel *1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range. *2 The surge current suppression element is a power thermistor. *3 Derating is required when the optional cover is attached. Specifications which provide more details for the proper and safe use of the described product are available upon request. All specifications are subject to change without notice. FAW Series Power Supplies AC Input Single Output, General-Purpose SPECIFICATIONS 100W TYPE Part No. FAW05-20R FAW12-8R3 FAW15-6R6 FAW24-4R2 FAW28-3R5 FAW48-2R0 1 Output voltage, current*5V • 20A 12V • 8.3A 15V • 6.6A 24V • 4.2A 28V • 3.5A 48V • 2A Maximum output power W 100 99.6 99 100.8 98 96 Input requirements Input voltage Eac V 85 to 264[Rating: 100-120, 200-240] Input frequency Hz 47 to 66[Single phase] Input current A 2.4max./1.6max.[100-120V/200-240V] Fuse rating A 5[Internal] Surge current A 25max./50max.[100-120V/200-240V, 1st surge current, reset after roughly 30s min.] Leakage current mA 0.5max./0.75max.[100-120V/200-240V] Efficiency % 78typ. Output characteristics Output voltage V 5 12 15 24 28 48 Voltage variable range V 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 25.2 to 30.8 43.2 to 52.8 1 Maximum output current*A 20 8.3 6.6 4.2 3.5 2 Overvoltage threshold V 6 to 6.9 13.7 to 15.7 17 to 19 27 to 30.5 32 to 35 53.5 to 60 Overcurrent threshold A 21 to 24 8.7 to 10 7 to 8 4.4 to 5.2 3.7 to 4.2 2.1 to 2.4 Input variation % 2max.(1typ.)[85 to 132V, 170 to 264V] Load variation % 2max.(1typ.)[10 to 100% load] Total variation ±2max.(±1typ.) Temperature Voltage stability % 2max.(1typ.)[0 to +50°C] variation Drift % 0.5max.(0.1typ.)[After input voltage ON for 30min to 8h] Dynamic load %/ms ±4max./1max.[50 to 100% sudden load change] Ripple Ep-p mV 80max. 100max. 120max. 150max. 180max. 260max. Ripple noise Ep-p mV 120max. 190max. 220max. 310max. 330max. 530max. Start up time ms 200max. Hold up time ms 15min. Accessory equipment Operation indicator LED illuminates when voltage output is ON. Overvoltage protection Voltage shielding type, recovers upon reset after roughly 90/120s[120/240V]. Overcurrent protection Fixed current threshold type, automatic recovery. Remote ON-OFF None Remote sensing Yes Current balance None Standards 2 Safety standards*UL1950, CSA C22.2 No. 234, EN60950(TÜV) approved. Noise terminal voltage FCC class B[100-120V], VDE0871 class B[220-240V] compliant. Construction External dimensions H·W·Lmm 95·35·200 Weight kg 1max. Mounting method Case material Frame: Aluminum Cover(Option): Steel *1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range. *2 Derating is required when the optional cover is attached. Specifications which provide more details for the proper and safe use of the described product are available upon request. All specifications are subject to change without notice. FAW Series Power Supplies AC Input Single Output, General-Purpose SPECIFICATIONS 150W TYPE Part No. FAW05-30R FAW12-12R FAW15-10R FAW24-6R0 FAW28-5R0 FAW48-2R8 1 Output voltage, current*5V • 30A 12V • 12A 15V • 10A 24V • 6A 28V • 5A 48V • 2.8A Maximum output power W 150 144 150 144 140 134.4 Input requirements Input voltage Eac V 85 to 264[Rating: 100-120, 200-240] Input frequency Hz 47 to 66[Single phase] Input current A 3.5max./2max.[100-120V/200-240V] Fuse rating A 6.3[Internal] Surge current A 25max./50max.[100-120V/200-240V, 1st surge current, reset after roughly 30s min.] Leakage current mA 0.5max./0.75max.[100-120V/200-240V] Efficiency % 78typ. Output characteristics Output voltage V 5 12 15 24 28 48 Voltage variable range V 4.5 to 5.5 10.8 to 13.2 13.5 to 16.5 21.6 to 26.4 25.2 to 30.8 43.2 to 52.8 1 Maximum output current*A 3012106 5 2.8 Overvoltage threshold V 6 to 6.9 13.7 to 15.7 17 to 19 27 to 30.5 32 to 35 53.5 to 60 Overcurrent threshold A 32 to 36 13 to 15 11 to 13 6.3 to 7.5 5.3 to 6.1 3 to 3.5 Input variation % 2max.(1typ.)[85 to 132V, 170 to 264V] Load variation % 2max.(1typ.)[10 to 100% load] Total variation ±2max.(±1typ.) Temperature Voltage stability % 2max.(1typ.)[0 to +50°C] variation Drift % 0.5max.(0.1typ.)[After input voltage ON for 30min to 8h] Dynamic load %/ms ±4max./1max.[50 to 100% sudden load change] Ripple Ep-p mV 80max. 100max. 120max. 150max. 180max. 260max. Ripple noise Ep-p mV 120max. 190max. 220max. 310max. 330max. 530max. Start up time ms 200max. Hold up time ms 15min. Accessory equipment Operation indicator LED illuminates when voltage output is ON. Overvoltage protection Voltage shielding type, recovers upon reset after roughly 90/120s[120/240V]. Overcurrent protection Fixed current threshold type, automatic recovery. Remote ON-OFF None Remote sensing Yes Current balance None Standards 2 Safety standards*UL1950, CSA C22.2 No.234, EN60950(TÜV) approved. Noise terminal voltage FCC class B[100-120V], VDE0871 class B[220 to 240V] compliant. Construction External dimensions H·W·Lmm 95·51·200 Weight kg 1.2max. Mounting method Case material Frame: Aluminum Cover(Option): Steel *1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range. *2 Derating is required when the optional cover is attached. Specifications which provide more details for the proper and safe use of the described product are available upon request. All specifications are subject to change without notice. FAW Series Power Supplies AC Input Single Output, General-Purpose TERMINAL DESIGNATIONS AND FUNCTIONS 15W, 25W TYPE 50W TYPE 100W TYPE 150W TYPE L L 1 L 1 N N L 1 N 1 2 2 N 2 –S 6 6 –S 2 – – 3 3 – –S 6 + + – – 4 6 +S 7 3 5 + + 5 4 + +S 6 +S 6 5 5 4 4 Terminal No. 1: AC input terminals(L, N) Terminal No. 5: Operation indicator LED Connect to single phase power supply, either AC. 100 to 120V or This green LED becomes illuminated when voltage is output. AC.200 to 240V. LED of the 100W and 150W models is mounted on a mini-board. Terminal No. 2: Frame ground terminal( ) Terminal No. 6: Remote sensing terminals(+S, –S) Connect to earth ground. This is connected to the case. These are normally jumpered. When controlling voltage to the Terminal No. 3: DC output terminals(+, –) load, please remove jumper, and connect wires to these termi- Connect to load. nals. Terminal No. 4: Output voltage adjustment trim Terminal No. 7: DC output terminals(+, +, –, –) 150W type Adjusts output voltage. These are wired to the loads. 20A max. allowable current per terminal. Use of terminal pairs is recommended. A121_FAW 980403 Specifications which provide more details for the proper and safe use of the described product are available upon request. All specifications are subject to change without notice.
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the FAW have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods