®
Intel S5000 Server Board
Family Datasheet
Intel order number D38960-006
Revision 1.3
August 31, 2007
Enterprise Platforms and Services Division
Revision History Intel® S5000 Server Board Family Datasheet
Revision History
Date Revision Modifications
Number
31 May 06 1.1 Initial Document Release.
10 Jun 07 1.2 Revised Sections 2.3, 3.13.1, 3.4.1, 3.7; Added Sections 2.4.15, 2.4.15.1;
Updated Table 3, 26.
Aug 31 07 1.3 Updated Sections 2.2.4, 3.2.1, 3.4.1, 3.4.2.3, 3.7.2.1.8; Updated Table 25 and
Figure 17
Disclaimers
®
Information in this document is provided in connection with Intel products. No license, express or
implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except
as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability
whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel
products including liability or warranties relating to fitness for a particular purpose, merchantability, or
infringement of any patent, copyright or other intellectual property right. Intel products are not intended for
use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and
product descriptions at any time, without notice.
Designers must not rely on the absence or characteristics of any features or instructions marked
"reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility
whatsoever for conflicts or incompatibilities arising from future changes to them.
This document contains information on products in the design phase of development. Do not finalize a
design with this information. Revised information will be published when the product is available. Verify
with your local sales office that you have the latest datasheet before finalizing a design.
The Intel® S5000 Server Board Family Datasheet may contain design defects or errors known as errata
which may cause the product to deviate from published specifications. Current characterized errata are
available on request.
This document and the software described in it, is furnished under license and may only be used or
copied in accordance with the terms of the license. The information in this manual is furnished for
informational use only, is subject to change without notice, and should not be construed as a commitment
by Intel Corporation. Intel Corporation assumes no responsibility or liability for any errors or inaccuracies
that may appear in this document or any software that may be provided in association with this document.
Except as permitted by such license, no part of this document may be reproduced, stored in a retrieval
system, or transmitted in any form or by any means without the express written consent of Intel
Corporation.
Intel, Pentium, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.
*Other brands and names may be claimed as the property of others.
Copyright © Intel Corporation 2006, 2007. All rights reserved.
ii Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Table of Contents
Table of Contents
1. Introduction...........................................................................................................................1
1.1 Server Product References......................................................................................1
1.2 Chapter Outline ........................................................................................................1
2. Functional Architecture .......................................................................................................2
®
2.1 Intel 5000 MCH Components .................................................................................4
®
2.1.1 Memory Controller Hub (Intel 5000 MCH) ..............................................................4
®
2.1.2 Intel 631xESB / 632xESB I/O Controller Hub (ESB2) ............................................7
2.2 Processor Sub-system ...........................................................................................11
2.2.1 Processor Support .................................................................................................12
2.2.2 Processor Population Rules...................................................................................12
2.2.3 Processor EVRD ....................................................................................................12
2.2.4 GTL2107 ................................................................................................................12
2.2.5 Common Enabling Kit (CEK) Design Support........................................................12
2.3 Memory Sub-system ..............................................................................................13
2.3.1 Fully-buffered DIMM (FBDIMM) .............................................................................14
2.3.2 Supported Memory.................................................................................................15
2.4 I/O Sub-system ......................................................................................................17
2.4.1 PCI Sub-system .....................................................................................................17
2.4.2 Scan Order.............................................................................................................17
2.4.3 Resource Assignment ............................................................................................17
2.4.4 Automatic IRQ Assignment ....................................................................................17
2.4.5 Legacy Option ROM Support .................................................................................18
2.4.6 EFI PCI APIs ..........................................................................................................18
2.4.7 Legacy PCI APIs ....................................................................................................18
2.4.8 Dual Video..............................................................................................................18
2.4.9 Parallel ATA (PATA) Support.................................................................................18
2.4.10 Serial ATA (SATA) Support....................................................................................19
2.4.11 SATA RAID Functionality .......................................................................................20
2.4.12 Serial Attached SCSI .............................................................................................20
2.4.13 Video Controller .....................................................................................................20
2.4.14 Network Interface Controller (NIC).........................................................................20
2.4.15 Wake On LAN / Power On LAN and Magic Packet* Support.................................20
Revision 1.3 iii
Intel order number D38960-006
Table of Contents Intel® S5000 Server Board Family Datasheet
2.4.16 USB Support ..........................................................................................................21
2.4.17 Native USB Support ...............................................................................................21
2.4.18 Legacy USB Support..............................................................................................21
2.4.19 Super I/O................................................................................................................21
2.4.20 BIOS Flash.............................................................................................................22
2.5 Clock Generation and Distribution .........................................................................23
3. System BIOS .......................................................................................................................24
3.1 BIOS Identification String .......................................................................................24
3.2 Processors .............................................................................................................25
3.2.1 CPUID ....................................................................................................................25
3.2.2 Multiple Processor Initialization..............................................................................26
3.2.3 Mixed Processor Steppings ...................................................................................26
3.2.4 Mixed Processor Families ......................................................................................26
3.2.5 Mixed Processor System Bus Speeds ...................................................................26
3.2.6 Mixed Processor Cache Sizes ...............................................................................27
3.2.7 Microcode Update ..................................................................................................27
3.2.8 Processor Cache....................................................................................................27
3.2.9 Mixed Processor Configuration ..............................................................................27
3.2.10 Hyper-Threading Technology.................................................................................28
®
3.2.11 Intel SpeedStep Technology ................................................................................28
® ®
3.2.12 Intel Extended Memory 64 Technology (Intel EM64T)........................................28
3.2.13 Execute Disable Bit Feature...................................................................................29
3.2.14 Enhanced Halt State (C1E)....................................................................................29
3.2.15 Multi-Core Processor Support................................................................................29
®
3.2.16 Intel Virtualization Technology..............................................................................30
3.2.17 Fake MSI Support ..................................................................................................30
3.2.18 Acoustical Fan Speed Control................................................................................31
3.3 Memory ..................................................................................................................32
3.3.1 Memory Sizing and Configuration ..........................................................................32
3.3.2 POST Error Codes .................................................................................................32
3.3.3 Publishing System Memory....................................................................................32
3.3.4 Mixed Speed Memory Modules..............................................................................34
3.3.5 Memory Test ..........................................................................................................34
3.3.6 Memory Scrub Engine............................................................................................35
3.3.7 Memory Map and Population Rules .......................................................................35
iv Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Table of Contents
3.3.8 Memory Modes of Operation..................................................................................38
3.3.9 Memory RAS..........................................................................................................38
3.3.10 Memory Error Handling ..........................................................................................40
3.4 Platform Control .....................................................................................................52
3.4.1 FBDIMM Open and Closed Loop Thermal Throttling.............................................53
3.4.2 Fan Speed Control .................................................................................................53
3.5 Flash ROM .............................................................................................................56
3.6 BIOS User Interface ...............................................................................................56
3.6.1 Logo / Diagnostic Screen .......................................................................................56
3.7 BIOS Setup Utility ..................................................................................................56
3.7.1 Operation ...............................................................................................................56
3.7.2 Server Platform Setup Screens..............................................................................60
3.8 Loading BIOS Defaults...........................................................................................97
3.9 Security ..................................................................................................................97
3.9.1 Operating Model.....................................................................................................97
3.9.2 Password Protection ..............................................................................................98
3.9.3 Password Clear Jumper.........................................................................................98
3.10 BIOS Update Flash Procedures.............................................................................98
3.10.1 Intel Iflash32 BIOS Update Utility...........................................................................98
®
3.10.2 Intel One Boot Flash Update Utility ......................................................................99
3.11 BIOS Bank Select and One Boot Flash Update...................................................101
3.11.1 BIOS Bank Select Jumper in Normal Mode (Jumper Pins 2 - 3 connected)........101
3.11.2 BIOS Bank Select Jumper in Recovery Mode (Jumper pins 1 - 2 connected).....102
3.12 OEM Binary..........................................................................................................102
3.12.1 Splash Logo .........................................................................................................102
3.13 Boot Device Selection ..........................................................................................102
3.13.1 USB Boot Device Reordering...............................................................................103
3.13.2 Server Managment Boot Device Control..............................................................103
3.14 Operating System Support...................................................................................103
3.14.1 Windows Compatibility .........................................................................................103
3.14.2 Advanced Configuration and Power Interface (ACPI)..........................................104
3.15 Front Control Panel Support ................................................................................104
3.15.1 Power Button........................................................................................................104
3.15.2 Reset Button ........................................................................................................105
3.15.3 Non-Maskable Interrupt (NMI) Button ..................................................................105
Revision 1.3 v
Intel order number D38960-006
Table of Contents Intel® S5000 Server Board Family Datasheet
3.16 Sleep and Wake Support .....................................................................................105
3.16.1 System Sleep States............................................................................................105
3.16.2 Wake Events / SCI Sources.................................................................................106
3.17 Non-Maskable Interrupt Handling ........................................................................106
3.18 BIOS Server Management ...................................................................................106
3.19 IPMI......................................................................................................................106
3.20 Console Redirection.............................................................................................107
3.20.1 Serial Configuration Settings................................................................................107
3.20.2 Keystroke Mappings.............................................................................................107
3.20.3 Limitations ............................................................................................................108
3.20.4 Interface to Server Management..........................................................................108
3.21 IPMI Serial Interface.............................................................................................108
3.21.1 Channel Access Modes .......................................................................................108
3.21.2 Interaction with BIOS Console Redirection ..........................................................108
3.22 Wired For Management (WFM)............................................................................109
3.22.1 PXE BIOS Support...............................................................................................109
3.23 System Management BIOS (SMBIOS) ................................................................109
4. System Management ........................................................................................................111
4.1 Feature Support ...................................................................................................111
4.1.1 Legacy Features ..................................................................................................111
4.1.2 New Features.......................................................................................................113
4.2 Power System ......................................................................................................113
4.3 BMC Reset Control ..............................................................................................115
4.3.1 BMC Exits Firmware Update Mode......................................................................115
4.4 System Initialization .............................................................................................115
4.4.1 Fault Resilient Booting (FRB)...............................................................................115
4.5 Integrated Front Panel User Interface..................................................................117
4.5.1 Power LED ...........................................................................................................117
4.5.2 System Status LED ..............................................................................................117
4.5.3 Chassis ID LED....................................................................................................119
4.5.4 Front Panel / Chassis Inputs ................................................................................119
4.5.5 Front Panel Lock-out Operation ...........................................................................120
2
4.6 Private Management I C Buses ..........................................................................121
4.7 Watchdog Timer...................................................................................................121
vi Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Table of Contents
4.8 System Event Log (SEL)......................................................................................121
4.8.1 Servicing Events ..................................................................................................122
4.8.2 SEL Erasure.........................................................................................................122
4.8.3 Timestamp Clock .................................................................................................122
4.9 Sensor Data Record (SDR) Repository................................................................123
4.9.1 Initialization Agent................................................................................................123
4.10 Field Replaceable Unit (FRU) Inventory Device...................................................123
4.11 Diagnostics and Beep Code Generation..............................................................124
4.12 NMI.......................................................................................................................124
4.12.1 Signal Generation ................................................................................................125
4.13 Processor Sensors...............................................................................................125
4.13.1 Processor Status Sensors....................................................................................126
4.13.2 Processor VRD Over-Temperature Sensor..........................................................126
4.13.3 ThermTrip Monitoring...........................................................................................127
4.13.4 Platform Enviroment Control Interface (PECI) Support........................................127
4.13.5 PROCHOT Support..............................................................................................127
4.13.6 IERR Monitoring...................................................................................................128
4.13.7 Dynamic Processor Voltage Monitoring ...............................................................128
4.13.8 Processor Temperature Monitoring......................................................................128
4.13.9 Processor Thermal Control Monitoring (Prochot).................................................129
4.13.10 CPU Population Error Sensor ..............................................................................129
4.14 Standard Fan Management .................................................................................129
4.14.1 Nominal Fan Speed .............................................................................................130
4.14.2 Stepwise Linear....................................................................................................130
4.14.3 Clamp...................................................................................................................131
4.14.4 Sleep State Fan Control.......................................................................................132
4.14.5 Fan Redundancy Detection..................................................................................132
4.14.6 Hot Swap Fan Support.........................................................................................132
4.15 Acoustic Management..........................................................................................132
4.15.1 Fan Profiles ..........................................................................................................132
4.15.2 Interactions with DIMM Thermal Management.....................................................132
4.16 PSMI Support.......................................................................................................133
4.17 System Memory RAS and Bus Error Monitoring..................................................133
4.17.1 SMI Timeout Sensor ............................................................................................133
4.17.2 Memory Sensor....................................................................................................133
Revision 1.3 vii
Intel order number D38960-006
Table of Contents Intel® S5000 Server Board Family Datasheet
4.17.3 Critical Interrupt Sensor .......................................................................................134
4.17.4 DIMM Status Sensors ..........................................................................................134
4.17.5 System Memory Redundancy Monitoring ............................................................135
4.17.6 System Memory Monitoring and System Boot .....................................................138
4.18 PCI Express* Support ..........................................................................................138
4.18.1 PCI Express Link Sensors ...................................................................................138
4.18.2 BMC Self-test .......................................................................................................138
4.19 Field Replaceable Unit (FRU) / Fault LED Control...............................................139
4.20 Hot-swap Backplane (HSBP) Support .................................................................139
® ®
4.21 Intel Remote Management Module (Intel RMM) Support .................................139
4.21.1 Discovery Sequence ............................................................................................139
4.21.2 Division of Network Traffic ...................................................................................140
4.21.3 Event Forwarding .................................................................................................140
4.21.4 Serial Routing.......................................................................................................141
4.21.5 Messaging Interfaces ...........................................................................................141
4.22 Channel Management..........................................................................................142
4.23 User Model...........................................................................................................142
4.24 Session Support...................................................................................................142
4.25 Media Bridging .....................................................................................................142
4.26 Host to BMC Communication Interface................................................................143
4.26.1 LPC / KCS Interface.............................................................................................143
4.26.2 Receive Message Queue.....................................................................................143
4.26.3 Server Management Software (SMS) Interface ...................................................143
4.26.4 SMM Interface......................................................................................................143
4.27 IPMB Communication Interface ...........................................................................144
4.27.1 PCI System Management Bus (SMBus) ..............................................................144
2
4.27.2 BMC as I C Master Controller on IPMB ...............................................................144
4.27.3 IPMB LUN Routing...............................................................................................145
4.28 Emergency Management Port (EMP) Interface ...................................................147
4.28.1 COM2 Port Switching...........................................................................................147
4.28.2 Basic Mode ..........................................................................................................147
4.28.3 Terminal Mode .....................................................................................................147
4.28.4 Invalid Password Handling...................................................................................149
4.28.5 Serial Ping Message Behavior .............................................................................149
4.29 LAN Interface .......................................................................................................150
viii Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Table of Contents
4.29.1 IPMI 1.5 Messaging .............................................................................................150
4.29.2 IPMI 2.0 Messaging .............................................................................................151
®
4.29.3 Intel 631xESB / 632xESB I/O Controller Hub Embedded LAN Channels ..........152
4.29.4 Address Resolution Protocol Support ..................................................................152
4.29.5 Internet Control Message Protocol Support .........................................................152
4.29.6 Serial-over-LAN (SOL) 2.0 ...................................................................................152
5. Error Reporting and Handling .........................................................................................153
5.1 Fault Resilient Booting (FRB)...............................................................................153
5.1.1 BSP POST Failures (FRB-2)................................................................................153
5.1.2 Operating System Load Failures (OS Boot Timer)...............................................153
5.2 Error Handling and Logging .................................................................................154
5.2.1 Error Sources and Types .....................................................................................154
5.2.2 Error Logging via SMI Handler.............................................................................154
5.2.3 Timestamp Clock Event .......................................................................................155
5.3 Error Messages and Error Codes ........................................................................156
5.3.1 Diagnostic LEDs...................................................................................................156
5.3.2 POST Code Checkpoints .....................................................................................157
5.3.3 POST Error Messages and Handling...................................................................160
5.3.4 POST Error Beep Codes......................................................................................162
5.3.5 POST Error Pause Option....................................................................................162
Glossary ...................................................................................................................................163
Reference Documents ............................................................................................................166
Revision 1.3 ix
Intel order number D38960-006
List of Figures Intel® S5000 Server Board Family Datasheet
List of Figures
®
Figure 1. Intel 5000 MCH Functional Architechture.....................................................................3
Figure 2. CEK Processor Mounting.............................................................................................13
Figure 3. FBD Topology ..............................................................................................................15
Figure 4. Identifying Banks of Memory........................................................................................16
Figure 5. General BIOS Screen Display Layout..........................................................................57
Figure 6. Setup Utility — Main Screen Display ...........................................................................61
Figure 7. Setup Utility — Advanced Screen Display ...................................................................64
Figure 8. Setup Utility — Processor Configuration Screen Display.............................................65
Figure 9. Setup Utility — Specific Processor Information Screen Display ..................................67
Figure 10. Setup Utility — Memory Configuration Screen Display..............................................69
Figure 11. Setup Utility — Memory RAS and Performance Configuration Screen Display.........71
Figure 12. Setup Utility — ATA Controller Configuration Screen Display ...................................73
Figure 13. Setup Utility — Mass Storage Configuration Screen Display.....................................76
Figure 14. Setup Utility — Serial Port Configuration Screen Display ..........................................77
Figure 15. Setup Utility — USB Controller Configuration Screen Display...................................79
Figure 16. Setup Utility — PCI Configuration Screen Display.....................................................81
Figure 17. Setup Utility — System Acoustic and Performance Configuration Screen Display....83
Figure 18. Setup Utility — Security Configuration Screen Display..............................................85
Figure 19. Setup Utility — Server Management Configuration Screen Display ..........................87
Figure 20. Setup Utility — Console Redirection Screen Display.................................................89
Figure 21. Setup Utility — Server Management System Information Screen Display.................90
Figure 22. Setup Utility — Setup Utility – Boot Options Screen Display .....................................92
Figure 23. Setup Utility — Setup Utility – Boot Manager Screen Display....................................94
Figure 24. Setup Utility — Error Manager Screen Display ..........................................................95
Figure 25. Setup Utility — Exit Screen Display ...........................................................................96
®
Figure 26. Intel 631xESB / 632xESB I/O Controller Hub Power / Reset Signals ....................114
Figure 27. DIMM Grouping........................................................................................................135
Figure 28. BMC IPMB Message Reception...............................................................................146
Figure 29. Location of Diagnostic LEDs on Server Board.........................................................157
x Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet List of Tables
List of Tables
Table 1. DIMM Module Capacities ..............................................................................................16
Table 2. NIC2 Status LED ...........................................................................................................20
Table 3. Supported Processor Configurations ............................................................................25
Table 4. Mixed Processor Configurations ...................................................................................27
Table 5. Memory Errors Captured by Error Manager..................................................................45
Table 6. DIMM Fault Indicator LEDs ...........................................................................................45
Table 7. System Status Indicator LEDs.......................................................................................46
Table 8. NMI Generation .............................................................................................................47
Table 9. Mirroring Mode Errors ...................................................................................................47
Table 10. POST Memory Error Handling.....................................................................................48
Table 11. Runtime Memory Error Handling, No Redundancy .....................................................49
Table 12. Runtime Error Handling, with Redundancy .................................................................50
Table 13. BIOS Setup Page Layout ............................................................................................58
Table 14. BIOS Setup: Keyboard Command Bar........................................................................59
Table 15. Setup Utility — Main Screen Fields.............................................................................62
Table 16. Setup Utility — Processor Configuration Screen Fields ..............................................65
Table 17. Setup Utility — Specific Processor Information Screen Fields....................................68
Table 18. Setup Utility — Memory Configuration Screen Fields .................................................69
Table 19. Setup Utility — Memory RAS and Performance Configuration Screen Fields ............71
Table 20. Setup Utility — ATA Controller Configuration Screen Fields.......................................74
Table 21. Setup Utility — Mass Storage Configuration Screen Fields ........................................76
Table 22. Setup Utility — Serial Ports Configuration Screen Fields............................................78
Table 23. Setup Utility — USB Controller Configuration Screen Fields ......................................79
Table 24. Setup Utility — PCI Configuration Screen Fields ........................................................82
Table 25. Setup Utility — System Acoustic and Performance Configuration Screen Fields .......84
Table 26. Setup Utility — Security Configuration Screen Fields .................................................86
Table 27. Setup Utility — Server Management Configuration Screen Fields..............................87
Table 28. Setup Utility — Console Redirection Configuration Fields ..........................................89
Table 29. Setup Utility — Server Management System Information Fields.................................91
Table 30. Setup Utility — Setup Utility – Boot Options Screen Display ......................................93
Table 31. Setup Utility — Setup Utility – Boot Manager Screen Display.....................................94
Table 32. Setup Utility — Error Manager Screen Fields .............................................................95
Table 33. Setup Utility — Exit Screen Fields...............................................................................96
Revision 1.3 xi
Intel order number D38960-006
List of Tables Intel® S5000 Server Board Family Datasheet
Table 34. Security Features Operating Model.............................................................................98
Table 35. NMI Error Messages .................................................................................................106
Table 36. Console Redirection Escape Sequences for Headless Operation ............................108
Table 37. BMC Reset Sources and Actions ..............................................................................115
Table 38. Power LED Indicator States ......................................................................................117
Table 39. System Status LED Indicator States .........................................................................118
Table 40. Chassis ID LED Indicator States ...............................................................................119
Table 41. Secure Mode versus ACPI State...............................................................................121
Table 42. BMC Beep Codes......................................................................................................124
Table 43. Processor Sensors....................................................................................................125
Table 44. Requirements for Processor Status ..........................................................................126
Table 45. Standard Channel Assignments................................................................................142
Table 46. Keyboard Controller Style Interfaces.........................................................................143
Table 47. BMC IPMB LUN Routing ...........................................................................................145
Table 48. Terminal Mode Commands .......................................................................................148
Table 49. Supported RMCP+ Cipher Suites..............................................................................151
Table 50. Supported RMCP+ Payload Types ...........................................................................151
Table 51. POST Progress Code LED Example.........................................................................156
Table 52. POST Code Checkpoints ..........................................................................................157
Table 53. POST Error Messages and Handling ........................................................................160
Table 54. POST Error Beep Codes...........................................................................................162
xii Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Introduction
1. Introduction
This datasheet provides information about features and regulatory information that is common
® ® ®
to Intel server boards and Intel workstation boards that use the Intel 5000 Series Chipset.
This is a companion document to the technical product specifications that are available for
®
each server or workstation board that uses the Intel 5000 MCH. To fully understand all
features of a particular server or workstation board that uses this chipset, you need to use
both this datasheet and the technical product specification that is available for your server
board or workstation board.
The target audience for this document is anyone wishing to obtain more in depth detail of the
server board or workstation board than that which is available in the User’s Guide or the
board-specific technical product specification. This is a technical document that is meant to
assist people with understanding and learning more about the specific features of the board.
1.1 Server Product References
® ®
This document applies to both specific Intel server boards and to specific Intel workstation
boards. Unless otherwise noted, all references to “Intel boards” or “board” apply to both server
boards and workstation boards that use this chipset.
1.2 Chapter Outline
This document is divided into the following chapters
Chapter 1 - Introduction
Chapter 2 - Functional Architecture
Chapter 3 - System BIOS
Chapter 4 - System Management
Chapter 5 - Error Reporting and Handling
Revision 1.3 1
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
2. Functional Architecture
This chapter provides a detailed description of the functionality associated with the
®
architectural blocks that comprise the Intel 5000 MCH. A diagram of the chipset functional
architecture is on the following page.
2 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
®
Figure 1. Intel 5000 MCH Functional Architechture
Revision 1.3 3
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
®
2.1 Intel 5000 MCH Components
The chipsets consist of two components that together are responsible for providing the interface
®
between all major sub-systems found on the Intel server or workstation board. These sub-
systems include the processor, memory, and I/O sub-systems. These components are:
® ®
Intel 5000 Memory Controller Hub (Intel 5000 MCH)
®
Intel Enterprise South Bridge 2 (Intel® 631xESB / 632xESB I/O Controller Hub)
The following sub-sections provide an overview of the primary functions and supported features
® ®
of each chipset component used on the Intel boards that utilize the Intel 5000 MCH. Later
sections in this chapter provide more detail on how each sub-system is implemented.
®
Note: See the Intel server board or workstation board technical product specification that
applies to your product for feature-specific support information.
®
2.1.1 Memory Controller Hub (Intel 5000 MCH)
®
The Intel 5000 MCH is a 1432-ball FC-BGA package configured to support the following
interfaces:
CPU dual, independent system bus at 667-, 1066-, or 1333-MHz operation.
Four fully-buffered DIMM (FBD) channels supporting fully-buffered DDR2 DIMMs
(FBDIMMs), 24-lane serial bus at 4.25 GB/s (533 MT/s) and 5.3 GB/s (667 MT/s) peak
theoretical bandwidth per channel. This allows a total of 17 GB/s and 21 GB/s peak
theoretical bandwidth for all four Channels combined.
One PCI Express* x8 port with an aggregate bandwidth of 4 GB/s interface to the Intel®
631xESB / 632xESB I/O Controller Hub.
One PCI Express x8 port with an aggregate bandwidth of 4 GB/s interface to x8 PCI
Express Connector.
One PCI Express x8 port with an aggregate bandwidth of 4 GB/s interface to x8 PCI
Express Connector.
One PCI Express x4 ESI port with an aggregate bandwidth of 2 GB/s interface to the
Intel® 631xESB / 632xESB I/O Controller Hub.
2.1.1.1 System Bus
® ®
The Intel 5000 MCH supports either single- or dual-processor configurations using the Intel
® ®
Xeon 5000 Sequence processor with a 2x 2 MB cache. The Intel 5000 MCH supports a base
®
system bus frequency of 266 MHz and 333 MHz for Intel 5000 Series Chipsets. The address
and request interface is double-pumped to 533 MHz, and the 64-bit data interface (+ parity) is
quad-pumped to 1066 MHz. This provides a matched system bus address and data bandwidths
of 8.5 GB/s.
4 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
®
2.1.1.2 Intel 5000 MCH Memory Sub-System Overview
®
The Intel 5000 MCH provides an integrated memory controller for direct connection to four
channels of registered fully-buffered DIMM (FBD) DDR2 533/667 MHz memory (stacked or
unstacked). Peak theoretical memory data bandwidth using FBD 533/667 MHz technology is 17
and 21.3 GB/s, respectively.
When all four memory channels are populated and operating, they function in lock-step mode.
The maximum supported FBD DDR2 533/667 MHz memory configuration is 64 GB.
®
The Intel 5000 MCH memory interface provides several reliability, availability, serviceability,
usability, and manageability (RASUM) features, including:
Memory mirroring allows two copies of all data in the memory subsystem (one on each
channel) to be maintained.
Memory sparing allows one DIMM per channel to be held in reserve and brought on-line
if another FBDIMM in the channel becomes defective.
Hardware periodic memory scrubbing, including demand scrub support.
Retry on uncorrectable memory errors.
®
Intel x4/x8 Single Device Data Correction (SDDC) for memory error detection and
correction of any number of bit failures in a single x4/x8 memory device.
Note: Memory sparing and memory mirroring are mutually exclusive.
2.1.1.3 PCI Express* Interface
®
The Intel 5000 MCH supports the PCI Express* high-speed serial I/O interface for superior I/O
®
bandwidth. The scalable PCI Express interface of the Intel 5000 MCH complies with the PCI
Express Interface Specification, Revision 1.0a.
®
The Intel 5000 MCH provides three x8 PCI Express* interfaces, each with a maximum
theoretical bandwidth of 4.2 GB/s. Each of these x8 PCI Express interfaces may alternatively be
configured as two independent x4 PCI Express interfaces. A PCI Express interface/port is
defined as a collection of lanes. Each lane (x1) consists of two striped differential pairs in each
direction (transmit and receive). The raw bit-rate on the data pins of 2.5 Gb/s, results in a real
bandwidth of 250 MB/s per pair, given the 8/10 bit encoding used to transmit data across this
interface.
®
The Intel 5000 MCH is a root-class component as defined in the PCI Express Interface
®
Specification. The PCI Express* interfaces of the Intel 5000 MCH support connections to a
variety of bridges and devices that are compliant with the same revision of the specification.
2.1.1.3.1 PCI Express* Training
To establish a connection between PCI Express* endpoints, the endpoints participate in a
sequence of steps called training. This sequence establishes the operational width of the link
and adjusts skews of the various lanes within a link so that the data sample points can correctly
take a data sample from the link.
Revision 1.3 5
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
In the case of a x8 port, the x4 link-pairs first attempt to train independently, and will collapse to
a single link at the x8 width upon detection of a single device returning link ID information
upstream. Once the number of links has been established, they negotiate to train at the highest
common width, and step down in its supported link widths to succeed in training. The result may
be that the link has trained as a x1 link.
Although the bandwidth of this link size is substantially lower than a x8 link or a x4 link, it allows
communication between the two devices. Software can then interrogate the device at the other
end of the link to determine why it failed to train at a higher width. This would not be possible
without support for the x1 link width.
Width negotiation is done only during training or retraining, not during recovery.
2.1.1.3.2 PCI Express* Retry
The PCI Express* interface incorporates a link-level retry mechanism. The hardware detects a
corrupted transmission packet and performs a retry of that packet and all following packets.
Although this causes a temporary interruption in the delivery of packets, the retry helps to
maintain the link integrity.
2.1.1.3.3 PCI Express* Link Recovery
If excessive errors occur, the hardware can determine that the quality of the connection is in
question and the end points can enter a quick training sequence, known as recovery. The width
of the connection will not be renegotiated, but the adjustment of skew between lanes of the link
might occur. This occurs without any software intervention, but the software might be notified.
2.1.1.3.4 PCI Express* Data Protection
The PCI Express* high-speed serial interface uses traditional CRC protection. The data packets
use a 32-bit CRC protection scheme, the same CRC-32 used by Ethernet. The smaller link
packets use a 16-bit CRC scheme. Since packets utilize 8B/10B encoding, and not all
encodings are used; this provides further data protection, as illegal codes can be detected. If
errors are detected on the reception of data packets due to various transients, these data
packets can be retransmitted. Hardware logic supports this link-level retry without software
intervention.
6 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
2.1.1.3.5 PCI Express* Retrain
If the hardware is unable to perform a successful recovery, then the link automatically reverts to
the polling state and initiates a full retraining sequence. This is a drastic event with an implicit
®
reset to the downstream device and all subordinate devices, and is logged by the Intel 5000
MCH as a "Link Down" error. If escalation of this event is enabled, software is notified of the link
DL_DOWN condition. If software is involved, then data is probably lost, and processes need to
be restarted. This is preferred over the taking down the system or going offline for an extended
time.
2.1.1.4 Enterprise South Bridge Interface (ESI)
®
A PCI interface is provided for a connection to the memory controller hub (Intel 5000 MCH).
Maximum realized bandwidth on this interface is 2 GB/s in each direction simultaneously, for an
aggregate of 4 GB/s. This PCI Express* interface is compliant with the PCI Express Base
Specification Revision 1.0a, and supports x4 and x8 bandwidths.
®
2.1.2 Intel 631xESB / 632xESB I/O Controller Hub (ESB2)
®
The Intel 631xESB / 632xESB I/O Controller Hub is a multi-function device that provides an
upstream hub interface for access to several embedded I/O functions and features, including:
Compliant with the PCI Express Base Specification, Revision 1.0a, with support for four
PCI Express* root ports (module-based hot-plug support) and two 1x4 downstream ports
(connector-based hot-swap support)
Compliant with the PCI-X Addendum to the PCI Local Bus Specification, Revision 1.0b
Compliant with the PCI Local Bus Specification, Revision 2.3 with support for 33 MHz
PCI operations
Compliant with the PCI Standard Hot-Plug Controller and Subsystem Specification,
Revision 1.0
ACPI 2.0 power management logic support
Enhanced DMA controller, interrupt controller, and timer functions
Integrated IDE controller with support for Ultra ATA100 / 66 / 33
Integrated SATA controller
Baseboard management controller (BMC)
USB host interface with support for eight USB 2.0 ports; via four UHCI host controllers;
and one EHCI high-speed host controller
Compliant with the System Management Bus (SMBus) Specification, Version 2.0 with
2
additional support for I C devices
Support for the Audio Codec ‘97, Revision 2.3 Specification
Low pin count (LPC) interface
®
Each function within the Intel 631xESB / 632xESB I/O Controller Hub has its own set of
configuration registers. Once configured, each appears to the system as a distinct hardware
controller that shares the same PCI bus interface.
Revision 1.3 7
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
2.1.2.1 PCI Interface
®
The Intel 631xESB / 632xESB I/O Controller Hub PCI interface supports a 33-MHz, Revision
2.3-compliant implementation. All PCI signals are 5-V tolerant, except for PME#. An integrated
®
PCI arbiter supports up to six external PCI bus masters in addition to the internal Intel
® ®
631xESB / 632xESB I/O Controller Hub requests. On Intel boards that use the Intel 5000
MCH, this PCI interface is used to support one on-board PCI device: the ATI* ES1000 video
controller.
2.1.2.2 PCI Express* Interface
®
The Intel 631xESB / 632xESB I/O Controller Hub provides PCI Express* root ports that are
compliant with the PCI Express Base Specification Revision 1.0a. The PCI Express root ports
can be statically configured as four x1 ports or ganged together to form one x4 port. Each root
port supports 250 MB/s bandwidth in each direction (500 MB/s concurrent).
®
The Intel 631xESB / 632xESB I/O Controller Hub implements two x4 downstream ports. The
maximum realized bandwidth on this interface is 1 GB/s in each direction simultaneously, for an
aggregate of 2 GB/s. These two ports can be configured as one x8 PCI Express* port. This PCI
Express interface is compliant with the PCI Express Base Specification Revision 1.0a.
2.1.2.3 PCI-X* Bus Interface
®
The Intel 631xESB / 632xESB I/O Controller Hub provides a PCI-X* bus interface that supports
®
conventional PCI and PCI-X Mode 1. The PCI-X interfaces on the Intel 631xESB / 632xESB
I/O Controller Hub are compliant with the following:
“PCI-X Addendum” to the PCI Local Bus Specification Revision 1.0b
“Mode 1” sections of the “PCI-X Electrical and Mechanical Addendum” to the PCI Local
Bus Specification Revision 2.0a
“PCI-X Protocol Addendum” to the PCI Local Bus Specification Revision 2.0a
®
The Intel 631xESB / 632xESB I/O Controller Hub supports PCI bus frequencies of 66 MHz,
100 MHz, and 133 MHz.
2.1.2.4 IDE Interface (Bus Master Capability and Synchronous DMA Mode)
®
The Intel 631xESB / 632xESB I/O Controller Hub has an integrated IDE controller with an
independent IDE signal channel that supports up to two IDE devices. This integrated
functionality provides the interface for IDE hard disks and ATAPI devices. Each IDE device can
have independent timings. The IDE interface supports PIO IDE transfers of up to 16 MB/s and
Ultra ATA transfers of up 100 MB/s. The IDE interface integrates 16x32-bit buffers for optimal
®
transfers and does not consume any ISA DMA resources. The IDE signal channels in the Intel
631xESB / 632xESB I/O Controller Hub can be configured to primary and secondary channels.
8 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
2.1.2.5 Serial ATA (SATA) Host Controller
The SATA host controller supports a combination of up to six SATA or four serial attached SCSI
(SAS) devices. This provides an interface for SATA hard disks and ATAPI devices. The SATA
interface supports PIO IDE transfers up to 16 MB/s and Serial ATA transfers up to 3.0 Gb/s (300
MB/s).
®
The SATA system for the Intel 631xESB / 632xESB I/O Controller Hub contains six
independent SATA signal ports that can be independently electrically isolated. Each SATA
device can have independent timings. They can be configured to the standard primary and
®
secondary channels. In addition, the controller hub offers the Intel Embedded Server RAID
Technology that enables data striping (RAID Level 0) for higher-performance or data mirroring
(RAID Level 1) for fault-tolerance between the two SATA drives, alleviating disk bottlenecks by
®
taking advantage of the dual, independent SATA controllers integrated in the Intel 631xESB /
632xESB I/O Controller Hub.
®
Note: See the Intel server board or workstation board technical product specification that
applies to your product for more information.
2.1.2.6 Baseboard Management Controller (BMC)
®
The BMC component of the Intel 631xESB / 632xESB I/O Controller Hub is provided by an
embedded ARC* controller and associated peripheral functionality that is used to provide the
baseboard management controller functionality that is required for IPMI-based server
®
management. The following is a summary of the Intel 631xESB / 632xESB I/O Controller Hub
management hardware features utilized by the BMC:
ARC4 processor with 16 Kb I-cache and D-cache
256 Kb of internal SRAM with dual port (one for code accesses and one for all other
accesses).
Expansion bus, allowing connection to external Flash PROM (asynchronous or
synchronous), an external SRAM or an external SDRAM.
Serial flash interface
Five SMB ports, two that support FML (either master or slave)
RS-232 serial port (UART)
Cryptographic module, supporting AES and RC4 encryption algorithms and SHA1 and
MD5 authentication algorithms with internal DMA and raw checksum support.
Two keyboard controller style (KCS) interfaces residing on the LPC bus
General-purpose input/output (GPIO) interface
MAC CSR interface
Timer interface
Host DMA interface
Revision 1.3 9
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
2.1.2.7 Low Pin Count (LPC) Interface
®
The Intel 631xESB / 632xESB I/O Controller Hub implements an LPC Interface as described in
the Low Pin Count Interface Specification, Revision 1.1. The low pin count (LPC) bridge function
®
of the Intel 631xESB / 632xESB I/O Controller Hub resides in PCI Device 31: Function 0. In
addition to the LPC bridge interface function, D31:F0 contains other functional units including
DMA, interrupt controllers, timers, power management, system management, GPIO, and RTC.
2.1.2.8 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt
Controller)
The DMA controller incorporates the logic of two 82C37 DMA controllers, with seven
independently programmable channels. Channels 0–3 are hardwired to 8-bit, count-by-byte
transfers, and channels 5 through 7 are hardwired to 16-bit, count-by-word transfers. Any two of
the seven DMA channels can be programmed to support fast Type-F transfers.
®
The Intel 631xESB / 632xESB I/O Controller Hub supports LPC DMA. LPC DMA and PC/PCI
®
DMA use the Intel 631xESB / 632xESB I/O Controller Hub’s DMA controller. LPC DMA is
handled through the use of the LDRQ# lines from peripherals and special encoding on LAD[3:0]
from the host. Single, demand, verify, and increment modes are supported on the LPC
interface. Channels 0–3 are 8 bit channels. Channels 5 through 7 are 16-bit channels. Channel
4 is reserved as a generic bus master request.
The timer / counter block contains three counters that are equivalent in function to those found
in one 82C54 programmable interval timer. These three counters are combined to provide the
system timer function, and speaker tone. The 14.31818-MHz oscillator input provides the clock
source for these three counters.
®
The Intel 631xESB / 632xESB I/O Controller Hub provides an ISA-compatible programmable
interrupt controller (PIC) that incorporates the functionality of two 82C59 interrupt controllers.
The two interrupt controllers are cascaded so that 14 external and two internal interrupts are
possible. In addition, the I/O Controller Hub supports a serial interrupt scheme. All of the
registers in these modules can be read and restored. This is required to save and restore the
system state after power has been removed and restored to the platform.
2.1.2.9 Advanced Programmable Interrupt Controller (APIC)
®
In addition to the standard ISA-compatible PIC described in the previous section, the Intel
631xESB / 632xESB I/O Controller Hub incorporates the Advanced Programmable Interrupt
Controller (APIC).
2.1.2.10 Universal Serial Bus (USB) Controller
®
The Intel 631xESB / 632xESB I/O Controller Hub contains an enhanced host controller
interface that supports USB high-speed signaling. High-speed USB 2.0 allows data transfers up
to 480 Mb/s, which is 40 times faster than full-speed USB. The I/O Controller Hub also contains
four universal host controller interface (UHCI) controllers that support USB full-speed and low-
speed signaling.
®
The Intel 631xESB / 632xESB I/O Controller Hub supports eight USB 2.0 ports. All eight ports
capable of high-speed, full-speed, and low-speed.
10 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
2.1.2.11 Real-time Clock (RTC)
®
The Intel 631xESB / 632xESB I/O Controller Hub contains a Motorola* MC146818A-compatible
real-time clock with 256 bytes of battery-backed RAM. The real-time clock performs two key
functions: keeping track of the time of day and storing system data, even when the system is
powered down. The RTC operates on a 32.768-KHz crystal and a separate 3-V lithium battery.
The RTC supports two lockable memory ranges. By setting bits in the configuration space, two
8-byte ranges can be locked to read and write accesses. This prevents unauthorized reading of
passwords or other system security information.
2.1.2.12 General-purpose Input/Output (GPIO)
General-purpose inputs and outputs are provided for custom system designs. The number of
®
inputs and outputs depends on the Intel 631xESB / 632xESB I/O Controller Hub configuration.
All unused GPI pins must be pulled high or low, so they are at a predefined level and do not
cause problems.
®
Note: See the Intel server board or workstation board technical product specification that
applies to your product for more information.
2.1.2.13 System Management Bus (SMBus 2.0)
®
The Intel 631xESB / 632xESB I/O Controller Hub contains a SMBus host interface that allows
2
the processor to communicate with SMBus slaves. This interface is compatible with most I C
2
devices. Special I C commands are implemented. The SMBus host controller for the I/O
Controller Hub provides a mechanism for the processor to initiate communications with SMBus
peripherals (slaves).
®
The Intel 631xESB / 632xESB I/O Controller Hub supports slave functionality, including the
Host Notify protocol. The host controller supports eight command protocols of the SMBus
interface: Quick Command, Send Byte, Receive Byte, Write Byte/Word, Read Byte/Word,
Process Call, Block Read/Write, and Host Notify.
See the System Management Bus (SMBus) Specification, Version 2.0 for more information.
2.2 Processor Sub-system
The support circuitry for the processor sub-system consists of the following:
Dual LGA771 zero insertion force (ZIF) processor sockets
Processor host bus AGTL+ support circuitry
Reset configuration logic
Processor module presence detection logic
BSEL detection capabilities
CPU signal level translation
Common enabling kit (CEK) CPU retention support
Revision 1.3 11
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
2.2.1 Processor Support
® ® ® ®
Intel boards that use the Intel 5000 MCH support one or two Intel Xeon 5000 sequence
processors that utilize a 667, 1066, or 1333 MHz system bus with frequencies starting at 3.67
® ®
GHz. Previous generations of the Intel Xeon processors are not supported on these boards.
2.2.2 Processor Population Rules
When two processors are installed, both must be of identical revision, core voltage, and
bus/core speed. When only one processor is installed, it must be in the socket labeled CPU1.
The other socket must be empty.
Processors must be populated in sequential order. Processor socket 1 (CPU1) must be
populated before processor socket 2 (CPU2). No terminator is required in the second processor
socket when using a single processor configuration.
The board is designed to provide up to 130 A of current per processor. Processors with higher
current requirements are not supported.
2.2.3 Processor EVRD
EVRD11.0, Enterprise Voltage Regulator Down, is a DC-to-DC converter that meets the
®
processor power requirements server platform. Processors supported by this VR are: Intel
5000 sequence processors and future processor technologies
EVRD11.0 incorporates functional changes from prior EVRD design guidelines.
2.2.4 GTL2107
® ®
The GTL2107 is a customized translator between dual Intel Xeon 5000 sequence processors,
®
system health management, Intel 631xESB / 632xESB I/O Controller Hub, and power supply
LVTTL and GTL signals. The GTL2107 is a 12-bit translator to interface between the 3.3-V
® ®
LVTTL chipset I/O and the Multi-Core Intel Xeon 5000 processor sequence processor GTL- /
GTL / GTL+ I/O. The device is designed for platform health management in dual-processor
applications.
2.2.5 Common Enabling Kit (CEK) Design Support
® ®
The Intel board complies with the Intel Common Enabling Kit (CEK) processor mounting and
thermal solution. The server board ships from Intel’s factory with a CEK spring snapped onto the
underside of the board beneath each processor socket. The CEK spring is removable to allow
the use of non-Intel heat sink retention solutions.
12 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
Heatsink assembly
Thermal Interface
Material (TIM)
TP02091
Server Board
CEK Spring
Chassis
AF000196
Figure 2. CEK Processor Mounting
2.3 Memory Sub-system
® ®
The Intel boards that use the Intel 5000 MCH support several fully-buffered (FBD) memory
modes of operation.
Single-channel mode (single DIMM mode)
Single-branch / dual-channel mode
Dual-branch / dual-channel mode (four channels)
Memory sparing mode
Memory mirroring mode
®
The Intel 5000 MCH provides an integrated memory controller for direct connection up to four
channels routed to eight connectors supporting registered DDR2-533 and DDR2-667 FBDIMM
memory (stacked or unstacked). Each channel can support up to 2 Dual Ranked FB-DIMM
DDR2 DIMMs. FBDIMM memory channels are organized in to two branches for support of RAID
1 (mirroring). The MCH can support up to 8 DIMMs or a maximum memory size of 32 GB
physical memory in non-mirrored mode and 16 GB physical memory in a mirrored configuration.
The read bandwidth for each FB-DIMM channel is 4.25 GB/s for DDR2 533 FB-DIMM memory
which gives a total read bandwidth of 17 GB/s for four FBDIMM channels. Thus, this provides
8.5 GB/s of write memory bandwidth for four FB-DIMM channels. The read bandwidth for each
FB-DIMM channel is 5.3GB/s for DDR2 667 FB-DIMM memory which gives a total read
bandwidth of 21GB/s for four FB-DIMM channels. Thus, this provides 10.7 GB/s of write
Revision 1.3 13
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
memory bandwidth for four FB-DIMM channels. The total bandwidth is based on read bandwidth
thus the total bandwidth is 17 GB/s for 533 and 21.0 GB/s for 667.
A pair of channels is a branch. Branch 0 consists of channel A and channel B, Branch 1
consists of channel C and channel D. A DIMM can have two ranks; a channel supports a
maximum of eight ranks.
In non-mirrored operation, the two DDR2 channels within a branch operate in lock-step and the
branches operate independently. When memory mirroring is configured, the channels operate in
lock-step under normal conditions, but independently under failure and recovery conditions.
®
The Intel 5000 MCH supports a burst length of four in either single-channel mode or dual-
channel mode. In dual-channel mode this results in eight 64-bit chunks (64-byte cache line)
from a single read or write. In single-channel mode, two reads or writes are required to access a
cache line of data.
Memory between 32 GB, and 32 GB minus 512 MB, is not accessible for use by the operating
system and may be lost to the user. This area is reserved for the BIOS, APIC configuration
space, PCI adapter interface, and virtual video memory space. This means that if 32 GB of
memory is installed, 31.5 GB of this memory is usable. The chipset should allow the remapping
of unused memory above the 32 GB address, but this memory may not be accessible to an
operating system that has a 32 GB memory limit.
2
To boot the system, the system BIOS uses a dedicated I C bus to retrieve DIMM information
®
needed to program the Intel 5000 MCH memory registers.
2.3.1 Fully-buffered DIMM (FBDIMM)
The fully-buffered DIMM (FBDIMM) memory interface provides a high-bandwidth, large-capacity
channel solution that has a narrow host interface. FBDIMMs use commodity DRAMs isolated
from the channel behind an advanced memory buffer (AMB) on the DIMM that allows a greater
number of devices per channel without loading the interconnect and affecting performance.
Memory capacity remains at a maximum of 36 devices per DIMM and total memory capacity
scales with DRAM bit density.
FBD is a differential pair, point-to-point interface. The interface consists primarily of 10
®
southbound differential pairs (outputs from the Intel 5000 MCH to the DIMMs) and 14
® ®
northbound differential pairs (inputs to the Intel 5000 MCH from the DIMMs). The Intel 5000
MCH is connected only to the closest FBDIMM in the channel and communicates with the AMB
on that FBDIMM. The AMB on the closest FBDIMM communicates with the AMB on the next
FBDIMM in the channel, and so on. This point-to-point solution eliminates problems associated
with a “stub-bus” architecture and allows memory capacity to increase without loading the
channel. The figure below shows the FBD topology.
14 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
Figure 3. FBD Topology
2.3.2 Supported Memory
®
The Intel 5000 MCH supports single-channel DIMM operation in which only one FBDIMM is
installed in DIMM socket A1. Population in other DIMM banks is not supported for single-
channel operation.
The server and workstation boards provide the maximum memory capacities outlined in Table
1, based on the number of DIMM slots provided and maximum supported memory loads by the
chipset. The minimum memory supported with the system running in single-channel memory
mode is 512 MB, using a single DIMM in the DIMM A1 socket.
Note: All Intel memory qualification is done by testing with complete memory banks of identical
memory modules in all DIMM sockets. Memory qualification does not include testing of single-
channel memory mode, mixed DIMM type and/or vendors.
Supported DIMM capacities are 512 MB, 1 GB, 2 GB, and 4 GB.
Revision 1.3 15
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
Table 1. DIMM Module Capacities
SDRAM Parts / SDRAM Technology Used 512Mb 1Gb 2Gb 4Gb
X8, single row 512MB 1GB 2GB 4GB
X8, double row 1GB 2GB 4GB 8GB
X4, single row 512MB 1GB 2GB 4GB
X4, Stacked, double row 1GB 2GB 4GB 8GB
DIMMs on channel A are paired with DIMMs on channel B to configure 4-way interleaving. Each
DIMM pair is referred to as a bank. The bank can be further divided into two rows, based on
single-sided or double-sided DIMMs. If both DIMMs in a bank are single-sided, only one row is
said to be present. For double-sided DIMMs, both rows are said to be present.
The server and workstation boards have eight DIMM slots, or four DIMM channels. Both DIMMs
in a channel should be identical (same manufacturer, CAS latency, number of rows, columns
and devices, timing parameters, etc.). Although DIMMs within a channel must be identical, the
BIOS supports various DIMM sizes and configurations, allowing the channels of memory to be
different. Memory sizing and configuration is guaranteed only for qualified DIMMs approved by
Intel.
Note: Some boards vary in memory capacity. See the server or workstation Technical Product
Specification that applies to your product for more information.
Branch 1 Branch 2
Ch 1 Ch 2 Ch 3 Ch 4
AF000169
Figure 4. Identifying Banks of Memory
16 Revision 1.3
Intel order number D38960-006
DIMM A1
DIMM A2
DIMM B1
DIMM B2
DIMM C1
DIMM C2
DIMM D1
DIMM D2
Intel® S5000 Server Board Family Datasheet Functional Architecture
2.4 I/O Sub-system
The I/O sub-system consists of several components:
PCI sub-system
Serial ATA (SATA) support
Serial-attached SCSI (SAS)
RAID support
Parallel ATA (PATA) support
Video controller
Network interface controller (NIC)
USB 2.0 support
Super I/O support
This section describes the function of each I/O interface and how they operate.
2.4.1 PCI Sub-system
2.4.2 Scan Order
The BIOS assigns PCI bus numbers in a depth-first hierarchy, in accordance with the PCI Local
Bus Specification, Revision 2.2. The bus number is incremented when BIOS locates a bridge
device that is not part of the chipset. Scanning continues on the secondary side of the bridge
until all subordinate buses are assigned numbers. PCI bus number assignments may vary from
boot to boot with varying presence of PCI devices with PCI-PCI bridges. If a device with a
bridge with a single bus behind it is inserted into a PCI bus, all subsequent PCI bus numbers
below the current bus are increased by one.
The bus assignments occur once, early in the BIOS boot process, and never change during the
pre-boot phase.
2.4.3 Resource Assignment
The BIOS resource manager assigns the PIC-mode interrupt for the devices that are accessed
by the legacy code. The BIOS will ensure the PCI BAR registers and the command register for
all devices are correctly set up to match the behavior of the legacy BIOS after booting to a
legacy operating system. Any legacy code cannot make any assumption about the scan order of
devices or the order in which resources are allocated to them.
In legacy mode, the BIOS supports the INT 1Ah PCI BIOS interface calls.
2.4.4 Automatic IRQ Assignment
The BIOS automatically assigns IRQs to devices in the system for legacy compatibility. No
method is provided to manually configure the IRQs for devices.
Revision 1.3 17
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
2.4.5 Legacy Option ROM Support
The legacy support code in the BIOS will dispatch the legacy option ROMs in the available
memory space in the address range 0C0000h-0DFFFFh and will follow all the legacy rules with
respect to the option ROM space. If room is available in the E segment, and both C and D
segments are already used, the BIOS will also shadow up to 0E7FFF. The BIOS allows the user
to disable the shadowing of the onboard PCI devices.
2.4.6 EFI PCI APIs
The BIOS provides standard PCI protocols as described in the Extensible Firmware Interface
Reference Specification, Version 1.1.
2.4.7 Legacy PCI APIs
In legacy mode, the system BIOS will support the INT 1Ah, AH = B1h functions as defined in the
PCI BIOS Specification, Revision 2.1. The system BIOS supports the real mode interface.
2.4.8 Dual Video
The BIOS supports single and dual video modes. Dual video mode is disabled by default.
In single video mode, the onboard video controller is disabled when an add-in video card
is detected.
In dual video mode, the onboard video controller is enabled and is the primary video
device. The external video card is allocated resources and is considered the secondary
video device.
Note: See the server or workstation Technical Product Specification that applies to your
product for more information.
2.4.9 Parallel ATA (PATA) Support
®
The integrated IDE controller of the Intel 631xESB / 632xESB I/O Controller Hub ICH6
provides one IDE channel. This IDE channel can support one optical drive. The IDE channels
can be configured and enabled or disabled by accessing the BIOS Setup Utility during POST.
The BIOS supports the ATA/ATAPI Specification, version 6. It initializes the embedded IDE
controller in the chipset south-bridge and the IDE devices that are connected to these devices.
The BIOS scans the IDE devices and programs the controller and the devices with their
optimum timings. The IDE disk read/write services that are provided by the BIOS use PIO
mode, but the BIOS will program the necessary Ultra DMA registers in the IDE controller so that
the operating system can use the Ultra DMA modes.
The BIOS initializes and supports ATAPI devices such as LS-120/240, CD-ROM, CD-RW, and
DVD-ROM drives.
18 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
2.4.9.1 Ultra ATA/100
®
The IDE interface of the Intel 631xESB / 632xESB I/O Controller Hub ICH DMA protocol
redefines signals on the IDE cable to allow both host and target throttling of data and transfer
rates of up to 100 MB/s.
2.4.9.2 IDE Initialization
The BIOS supports the ATA/ATAPI Specification, version 6. The BIOS initializes the embedded
®
IDE controller in the chipset (Intel 631xESB / 632xESB I/O Controller Hub) and the IDE device
that is connected to this device. The BIOS scans the IDE device and programs the controller
and the device with their optimum timings. The IDE disk read/write services that are provided by
the BIOS use PIO mode, but the BIOS programs the necessary Ultra DMA registers in the IDE
controller so the operating system can use the Ultra DMA modes.
2.4.10 Serial ATA (SATA) Support
®
The integrated Serial ATA (SATA) controller of the Intel 631xESB / 632xESB I/O Controller
Hub provides up to six SATA or four SAS devices ports on the server board. The SATA ports
can be enabled / disabled and/or configured through the BIOS Setup Utility.
The BIOS initializes and supports SATA devices just like PATA devices. It initializes the
embedded IDE controllers in the chipset and any SATA devices that are connected to these
controllers. From a software standpoint, SATA controllers present the same register interface as
PATA controllers. Hot-plugging SATA drives during the boot process is not supported by the
BIOS and may result in undefined behavior.
®
The SATA function in the Intel 631xESB / 632xESB I/O Controller Hub has dual modes of
operation to support different operating system conditions. In the case of native IDE-enabled
®
operating systems, the Intel 631xESB / 632xESB I/O Controller Hub has separate PCI
functions for serial and parallel ATA. To support legacy operating systems, there is only one PCI
function for both the serial and parallel ATA ports.
The MAP register provides the ability to share PCI functions. When sharing is enabled, all I/O
decoding is done through the SATA registers. A software write to the Function Disable Register
(D31, F0, offset F2h, bit 1) causes Device 31, Function 1 (IDE controller) to be hidden and its
configuration registers are not used. The SATA Capability Pointer Register (offset 34h) will
change to indicate that Message Signaled Interrupt (MSI) is not supported in combined mode.
®
The Intel 631xESB / 632xESB I/O Controller Hub SATA controller features two sets of interface
signals that can be independently enabled or disabled. Each interface is supported by an
®
independent DMA controller. The Intel 631xESB / 632xESB I/O Controller Hub SATA controller
interacts with an attached mass storage device through a register interface that is equivalent to
that which is presented by a traditional IDE host adapter. The host software follows existing
standards and conventions when accessing the register interface and follows standard
command protocol conventions.
SATA interface transfer rates are independent of UDMA mode settings. SATA interface transfer
rates will operate at the bus’s maximum speed, regardless of the UDMA mode reported by the
SATA device or the system BIOS.
Revision 1.3 19
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
2.4.11 SATA RAID Functionality
See the server or workstation Technical Product Specification that applies to your product for
information.
2.4.12 Serial Attached SCSI
See the server or workstation Technical Product Specification that applies to your product for
information.
2.4.13 Video Controller
See the server or workstation Technical Product Specification that applies to your product for
information.
2.4.14 Network Interface Controller (NIC)
®
The Intel server boards that use the S5000P chipset support two 10Base-T / 100Base /
®
1000Base-T network interface controllers (NIC) based on the Intel 82563EB controller. The
®
Intel workstation boards that use the S5000X chipset support one 10Base-T / 100Base /
®
1000Base-T network interface controller (NIC) based on the Intel 82564EB controller.
Each network interface controller (NIC) drives two LED’s located on each network interface
connector. The link/activity LED (to the left of the connector) indicates network connection when
on, and Transmit/Receive activity when blinking. The speed LED (to the right of the connector)
indicates 1000-Mbps operation when amber, 100-Mbps operation when green, and 10 Mbps
when off. The table below provides an overview of the LED’s.
Table 2. NIC2 Status LED
LED Color LED State NIC State
Off 10 Mbps
Green/Amber (Left)
Green 100 Mbps
Amber 1000 Mbps
On Active Connection
Green (Right)
Blinking Transmit / Receive activity
2.4.15 Wake On LAN / Power On LAN and Magic Packet* Support
The server board supports Wake On LAN / Power On LAN capability using the onboard network
interface chips or an add-in network interface card. An add-in network card can deliver the wake
signal to the server board via the PME signal on the PCI bus. The actual support for Magic
Packet and/or packet filtering for Wake On LAN / Power On LAN is provided by the NIC. The
server board handles the corresponding wake signal.
2.4.15.1 Wake On LAN with S4/S5
A configuration option is provided that allows the onboard NICs to be enabled to wake the
system in an S4/S5 state, even if the operating system disabled Wake-On-LAN when it powered
down the system. This provides an option for users who want to use standard, but non-secure,
WOL capability for operations such as after-hours maintenance. The DPC LAN capability
20 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
provides a secure system power-up, plus the ability to provide BIOS boot options, by sending
authenticated IPMI messages directly to the BMC via the onboard NICs.
2.4.16 USB Support
®
The USB controller functionality integrated into the Intel 631xESB / 632xESB I/O Controller
Hub ICH6 provides the server board with the interface for up to eight USB 2.0 ports. One
internal USB 2.0 port is provided to support a USB internal floppy disk drive. One internal 1x10
header is provided to support an additional two optional USB 2.0 ports. USB 2.0 ports are
routed through the bridge board connector for optional front access.
2.4.17 Native USB Support
During the power on self-test (POST), the BIOS initializes and configures the USB subsystem in
accordance with chapter 14 of the Extensible Firmware Interface Reference Specification,
Version 1.1. The BIOS is capable of initializing and using the following types of USB devices:
USB Specification-compliant keyboards
USB Specification-compliant mice
USB Specification-compliant storage devices that utilize bulk-only transport mechanism
USB devices are scanned to determine if they are required for booting.
The BIOS supports USB 1.1-compliant devices and host controllers. The BIOS configures the
USB 2.0-compliant host controller and USB 2.0-compliant devices in USB 1.1 mode because all
USB 2.0 devices are required to support USB 1.1 mode. Although USB 1.1 mode is slower than
USB 2.0 mode, the difference in speed is not significant during the pre-boot phase. The
operating system can reconfigure the USB devices in USB 2.0 mode as required. The BIOS
configures the USB 2.0 host controller (EHCI) so the operating system can use it.
During the pre-boot phase, the BIOS automatically supports the hot addition and hot removal of
USB devices. For example, if a USB device is hot plugged, the BIOS detects the device
insertion, initializes the device, and makes it available to the user. Only onboard USB controllers
are initialized by BIOS. This does not prevent the operating system from supporting any
available USB controllers, including on add-in cards.
2.4.18 Legacy USB Support
The BIOS supports PS/2* emulation of USB keyboards and mice. During POST, the BIOS
initializes and configures the root hub ports and then searches for a keyboard, a mouse, and the
USB hub then enables them.
2.4.19 Super I/O
Legacy I/O support is provided by a National Semiconductor* PC87427 Super I/O device. This
chip contains the necessary circuitry to control two serial ports and PS/2-compatible keyboard
®
and mouse. The Intel server and workstation boards that use this chipset support the following:
GPIOs
Revision 1.3 21
Intel order number D38960-006
Functional Architecture Intel® S5000 Server Board Family Datasheet
Two serial ports
Removable media drives
Keyboard and mouse support
Wake up control
System health support
2.4.19.1 General Purpose Input/Output (GPIO)
The National Semiconductor* PC87427 Super I/O provides nine general-purpose input/output
pins that the server and workstation boards utilize.
Note: See the server or workstation Technical Product Specification that applies to your product
for information.
2.4.19.2 Removable Media Drives
The BIOS supports removable media devices in accordance with the Tested Hardware and
Operating System List. The BIOS supports booting from USB mass storage devices connected
to the chassis USB port, such as a USB flash drive device. The BIOS supports USB 2.0 media
storage devices that are backward compatible to the USB 1.1 specification.
2.4.19.3 Keyboard and Mouse
Dual stacked PS/2* ports on the back edge of the server board support a keyboard and mouse.
Either port can support a mouse or keyboard. Neither port supports hot plugging, or connector
insertion, while the system is turned on.
The system can boot without a keyboard or mouse attached. If present, the BIOS will detect the
keyboard during POST and displays the message “Keyboard Detected” on the POST screen.
2.4.19.4 Wake-up Control
The Super I/O contains functionality that allows various events to control the power-on and
power-off the system.
Note See the server or workstation Technical Product Specification that applies to your product
for information.
2.4.20 BIOS Flash
®
The BIOS supports the Intel 28F320C3B flash part. The flash part is a 4 MB flash ROM, of
which 2 MB is programmable. The flash ROM contains system initialization routines, a setup
utility, and runtime support routines. The layout is subject to change, as determined by Intel.
The flash ROM contains the necessary drivers for onboard peripherals such as SCSI, Ethernet,
and video controllers. The Flash Memory Update utility loads the BIOS image into the flash.
22 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Functional Architecture
2.5 Clock Generation and Distribution
® ®
All buses on the Intel server and workstation boards that use the Intel 5000 MCH operate
using synchronous clocks. Clock synthesizer/driver circuitry on the server board generates
clock frequencies and voltage levels as required, including the following:
200-MHz differential clock at 0.7V logic levels. For processor 1, processor 2, debug port,
®
and the Intel 5000 MCH.
100-MHz differential clock at 0.7V logic levels on CK409B. For the DB800 clock buffer.
100-MHz differential clock at 0.7 Vlogic levels on DB800. For the PCI Express* device
®
this is the Intel 5000 MCH, which includes x4 PCI Express slot. For SATA this is the
®
Intel 631xESB / 632xESB I/O Controller Hub ICH6.
®
66 MHz at 3.3V logic levels: for 5000 North Bridge and the Intel 631xESB / 632xESB
I/O Controller Hub ICH6.
®
48 MHz at 3.3V logic levels: for Intel 631xESB / 632xESB I/O Controller Hub ICH6 and
SIO.
®
33 MHz at 3.3V logic levels: for the Intel 631xESB / 632xESB I/O Controller Hub ICH6,
video, BMC, and SIO.
®
14.318 MHz at 2.5V logic levels: For the Intel 631xESB / 632xESB I/O Controller Hub
ICH6 and video.
10 Mhz at 5V logic levels: For the BMC.
The PCI-X slot speed on the full-length riser card is determined by the riser card in use.
Revision 1.3 23
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3. System BIOS
The BIOS is implemented as firmware that resides in the Flash ROM. It provides hardware-
specific initialization algorithms and standard PC-compatible basic input / output (I/O) services,
®
and standard Intel Server Board features. The Flash ROM also contains firmware for certain
embedded devices. These images are supplied by the device manufacturers and are not
specified in this document.
®
The BIOS implementation is based on the Intel Platform Innovation Framework for EFI
architecture and is fully compliant with all Intel Platform Innovation Framework for EFI
architecture specifications specified in the Extensible Firmware Interface Reference
Specification, Version 1.1. The Intel Platform Innovation Framework for EFI is referred to as
“Framework” in this document.
3.1 BIOS Identification String
The BIOS Identification string is used to uniquely identify the revision of the BIOS being used on
the server. The string is formatted as follows:
BoardID.OEMID.MajorRev.MinorRev.BuildID.BuildDateTime
Build Date and time in
MMDDYYYYHHMM format
4 character ID
2 character ID
2 character ID
3 character ID – “86B” = EPSD
N character ID – S5000PSL, etc
For example, BIOS build 3, generated on August 13, 2005 at 11:56 AM has the following BIOS
ID string that will be displayed in the POST diagnostic screen:
S5000.86B.01.00.0003.081320051156
The BIOS version in the BIOS Setup utility is displayed as:
S5000.86B.01.00.0003
24 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
The BIOS ID is used to identify the BIOS image. It is not used to designate either the board ID
or the BIOS phase. The board ID is available in the SMBIOS type 2 structure in which the phase
of the BIOS can be determined by the release notes associated with the image. The board ID is
also available in BIOS Setup.
3.2 Processors
3.2.1 CPUID
® ®
The following processors are supported on Intel server boards and systems that use the Intel
5000 Series Chipset, with their respective CPU ID:
® ®
Dual-Core Intel Xeon Processor 5000 series: CPU ID – 00000F6xh
® ®
Dual-Core Intel Xeon Processor 5100 series: CPU ID – 000006Fxh
® ®
Quad-Core Intel Xeon Processor 5300 series: CPU ID – 000006Fxh
® ®
45nm 2P Dual-Core Intel Xeon Processors: TBD
® ®
45nm 2P Quad-Core Intel Xeon Processors: TBD
Table 3. Supported Processor Configurations
Processor Family System Bus Speed Core Frequency Cache Watts Support
® ®
Intel Xeon Processor 533 MHz All No
® ®
Intel Xeon Processor 800 MHz All No
® ®
Intel Xeon Processor 5030 667 MHz 2.66 2 MB 95 Yes
® ®
Intel Xeon Processor 5050 667 MHz 3.0 GHz 2 MB 95 Yes
® ®
Intel Xeon Processor 5060 1066 MHz 3.2 GHz 2 MB 130 Yes
® ®
Intel Xeon Processor 5063 1066 MHz 3.2 GHz 2 MB 95 Yes
® ®
Intel Xeon Processor 5080 1066 MHz 3.73 GHz 2 MB 130 Yes
® ®
Intel Xeon Processor 5110 1066 MHz 1.60 GHz 4 MB 65 Yes
® ®
Intel Xeon Processor 5120 1066 MHz 1.86 GHz 4 MB 65 Yes
® ®
Intel Xeon Processor 5130 1333 MHz 2.00 GHz 4 MB 65 Yes
® ®
Intel Xeon Processor 5138 1066 MHz 2.13 GHz 4MB 35 Yes
® ®
Intel Xeon Processor 5140 1333 MHz 2.33 GHz 4 MB 65 Yes
® ®
Intel Xeon Processor 5148 1333 MHz 2.33 GHz 4 MB 40 Yes
® ®
Intel Xeon Processor 5150 1333 MHz 2.66 GHz 4 MB 65 Yes
® ®
Intel Xeon Processor 5160 1333 MHz 3.00 GHz 4 MB 80 Yes
® ®
Intel Xeon Processor L5310 1066 MHz 1.60 GHz 8MB 50 Yes
® ®
Intel Xeon Processor L5320 1066 MHz 1.86 GHz 8MB 50 Yes
® ®
Intel Xeon Processor E5310 1333 MHz 1.6 GHz 8 MB 80 Yes
® ®
Intel Xeon Processor E5320 1333 MHz 1.86 GHz 8 MB 80 Yes
® ®
Intel Xeon Processor E5335 1333 MHz 2.00 GHz 8 MB 80 Yes
® ®
Intel Xeon Processor E5345 1333 MHz 2.33 GHz 8 MB 80 Yes
® ®
Intel Xeon Processor X5355 1333 MHz 2.66 GHz 8 MB 120 Yes
®
45nm 2P Dual-Core Intel TBD TBD TBD TBD Yes*
®
Xeon Processors*
Revision 1.3 25
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
®
45nm 2P Quad-Core Intel TBD TBD TBD TBD Yes*
®
Xeon Processors*
®
* Only specific product codes of the Intel S5000 server and workstation board family can
support the 45nm 2P Dual-Core or 45nm 2P Quad-Core Intel® Xeon® Processors. See the
server or workstation Technical Product Specification that applies to your product for more
information on dual-core or quad-core processor support.
*Only Intel® Xeon processors with system bus speeds of 667MHz, 1066MHz or 1333MHz are
supported in the Intel® S5000 server and workstation board family.
3.2.2 Multiple Processor Initialization
IA-32 processors have a microcode-based bootstrap processor (BSP) arbitration protocol. A
processor that does not perform the role of BSP is referred to as an application processor (AP).
®
The Intel 5000 Series Chipset memory controller hub (MCH) has two processor system buses,
® ®
each of which accommodates a single Multi-Core Intel Xeon processor 5000 sequence. At
reset, the hardware arbitration chooses one BSP from the available processor cores per system
bus. However, the BIOS power-on self-test (POST) code requires only one processor for
®
execution. This requires the BIOS to elect a system BSP using registers in the Intel 5000 MCH.
The BIOS cannot guarantee which processor will be the system BSP, only that a system BSP
will be selected. In the remainder of this document, the system BSP is referred to as the BSP.
The BSP is responsible for executing the BIOS POST and preparing the server to boot the
operating system. At boot time, the server is in virtual wire mode and the BSP alone is
programmed to accept local interrupts (INTR driven by programmable interrupt controller (PIC)
and non-maskable interrupt (NMI).
As a part of the boot process, the BSP wakes each AP. When awakened, an AP programs its
memory type range registers (MTRRs) to be identical to those of the BSP. All APs execute a
halt instruction with their local interrupts disabled. If the BSP determines that an AP exists that
is a lower-featured processor or that has a lower value returned by the CPUID function, the BSP
switches to the lowest-featured processor in the server. The system management mode (SMM)
handler expects all processors to respond to a system management interrupt (SMI).
3.2.3 Mixed Processor Steppings
For optimum performance, only identical processors should be installed. Processor stepping
within a common processor family can be mixed as long as it is listed in the processor
specification updates published by Intel Corporation. The BIOS does not check for mixed
® ®
processor steppings. See the Intel Xeon Processor Specification Update for supported mixed
processor steppings. See also Table 4 .
3.2.4 Mixed Processor Families
Processor families cannot be mixed. If this condition is detected, an error is reported to the
BMC. See Table 4.
3.2.5 Mixed Processor System Bus Speeds
Processors with different system bus speeds cannot be mixed. If this condition is detected, an
error is reported to the BMC. See Table 4 for details.
26 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.2.6 Mixed Processor Cache Sizes
If the installed processors have mixed cache sizes, an error is reported to the BMC. The size of
all cache levels must match between all installed processors. See Table 4.
3.2.7 Microcode Update
If the system BIOS detects a processor for which a microcode update is not available, the BIOS
reports an error to the BMC. See Table 4.
IA-32 processors can correct specific errata by loading an Intel-supplied data block, known as a
microcode update. The BIOS stores the update in non-volatile memory and loads it into each
processor during POST. The BIOS allows a number of microcode updates to be stored in the
flash. This is limited by the amount of free space available.
3.2.8 Processor Cache
The BIOS enables all levels of processor cache as early as possible during POST. There are no
user options to modify the cache configuration, size, or policies. All detected cache sizes are
reported in the SMBIOS Type 7 structures. The largest and highest-level cache detected is
reported in BIOS Setup.
3.2.9 Mixed Processor Configuration
®
The following table describes mixed processor conditions and actions for all Intel server boards
®
and systems that use the Intel 5000 Series Chipset. Errors fall into one of two categories:
Halt: If the system can boot it will go directly to the error manager, regardless of the
“Post Error Pause” setup option.
Pause: If “Post Error Pause” setup option is enabled, system will go directly to the error
manager. Otherwise the system will continue to boot and no prompt is given for the
error. The error is logged to the error manager.
Table 4. Mixed Processor Configurations
Error Severity System Action
Processor family not Fatal The BIOS detects the error condition and responds as follows:
Identical
Logs the error into the system event log (SEL)
Alerts the BMC of the configuration error with an IPMI command.
Does not disable the processor
Displays “0194: Processor family mismatch detected” message in
the error manager
Halts the system
Processor cache not Fatal The BIOS detects the error condition and responds as follows:
identical
Logs the error into the SEL
Alerts the BMC of the configuration error with an IPMI command.
Does not disable the processor
Displays “0192: Cache size mismatch detected” message in the
error manager
Halts the system
Revision 1.3 27
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Error Severity System Action
Processor frequency (speed) Major The BIOS detects the error condition and responds as follows:
not identical
Adjusts all processor frequencies to lowest common denominator
Continues to boot the system successfully
If the frequencies for all processors cannot all be adjusted to be the
same, then the BIOS:
Logs the error into the SEL
Displays “0197: Processor speeds mismatched” message in the
error manager
Halts the system
Processor microcode Fatal The BIOS detects the error condition and responds as follows:
missing
Logs the error into the SEL
Alerts the BMC of the configuration error with an IPMI command.
Does not disable processor
Displays “816x: Processor 0x unable to apply microcode update”
message in the error manager
Pauses the system for user intervention
Processor FSB speeds not Fatal The BIOS detects the error condition and responds as follows:
identical
Logs the error into the system event log (SEL)
Alerts the BMC of the configuration error with an IPMI command.
Does not disable processor
Displays “0195: Processor Front Side Bus speed mismatch
detected” message in the error manager
Halts the system
3.2.10 Hyper-Threading Technology
® ®
Intel Xeon processors support Hyper-Threading Technology. The BIOS detects processors
that support this feature and enables the feature during POST. BIOS Setup provides an option
to enable or disable this feature. The default is enabled.
The BIOS creates additional entries in the ACPI MP tables to describe the virtual processors.
The SMBIOS Type 4 structure shows only the physical processors installed. It does not
describe the virtual processors.
Because some operating systems are not able to efficiently utilize the Hyper-Threading
Technology, the BIOS does not create entries in the Multi-Processor Specification tables to
describe the virtual processors.
®
3.2.11 Intel SpeedStep Technology
® ® ®
Intel Xeon processors support the Geyserville feature of the Intel SpeedStep technology.
This feature changes the processor operating ratio and voltage similar to the Thermal Monitor 1
(TM1) feature. Geyersville must be used in conjunction with the TM1. The BIOS implements the
Geyserville feature in conjunction with the TM1 feature.
® ®
3.2.12 Intel Extended Memory 64 Technology (Intel EM64T)
The system BIOS does the following:
28 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
® ®
Detects whether the processor is Intel Extended Memory 64 Technology (Intel EM64T)
capable
Initializes the SMBASE for each processor
Detects the appropriate SMRAM State Save Map used by the processor
®
Enables Intel EM64T during memory initialization if necessary
3.2.13 Execute Disable Bit Feature
®
The Execute Disable Bit feature (XD bit) is an enhancement to the IA-32 Intel architecture. An
IA-32 processor that supports the Execute Disable Bit feature can prevent data pages from
being used by malicious software to execute code. An IA-32 processor with the XD bit feature
can provide memory protection in either of the following modes:
Legacy protected mode if the Physical Address Extension (PAE) is enabled.
IA-32e mode when 64-bit extension technology is enabled (Entering IA-32e mode
requires enabling PAE).
The XD bit does not introduce any new instructions, it requires operating systems to operate in
a PAE-enabled environment and establish a page-granular protection policy for memory. The
XD bit can be enabled and disabled in BIOS Setup. The default behavior is enabled.
3.2.14 Enhanced Halt State (C1E)
All processors support the Halt State (C1) through the native processor instructions HLT and
MWAIT. Some processors implement an optimization of the C1 state called the Enhanced Halt
State (C1E) to further reduce the total power consumption while in C1. When C1E is enabled,
and all logical processors in the physical processors have entered the C1 state, the processor
will reduce the core clock frequency to system bus ratio and VID. The transition of the physical
®
processor from C1 to C1E is accomplished similar to an Enhanced Intel SpeedStep
Technology transition. If the BIOS determines all the system processors support C1E, then it is
enabled.
3.2.15 Multi-Core Processor Support
The BIOS does the following:
Initializes all processor cores
Installs all NMI handlers for all dual core processors
Leaves initialized AP in CLI/HLT loop
Initializes stack for all APs
BIOS Setup provides an option to selectively enable or disable multi-core processor support.
The default behavior is enabled.
The BIOS creates additional entries in the ACPI MP tables to describe the dual core
processors. The SMBIOS Type 4 structure shows only the physical processors installed. It does
not describe the virtual processors.
Revision 1.3 29
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
The BIOS will create entries in the multi-processor specification tables to describe dual core
processors.
®
3.2.16 Intel Virtualization Technology
®
Intel Virtualization Technology is designed to support multiple software environments sharing
the same hardware resources. Each software environment may consist of operating system and
®
applications. The Intel Virtualization Technology can be enabled or disabled in BIOS Setup.
The default behavior is disabled.
®
Note: If the Setup options are changed to enable or disable the Intel Virtualization Technology
setting in the processor, the user must perform an AC power cycle before the changes will take
effect.
3.2.17 Fake MSI Support
In PCI compatible INTx mode, the Intel® 5000 Series Chipsets supports a maximum of four
unique interrupts. If more than four unique interrupts are used by devices behind the Intel®
5000 Series Chipset root ports, it could result in a potential interrupt scaling problem due to
sharing of interrupts. On an Intel® 5000 based platform that supports eight processor cores, the
configuration allows for interrupt distribution to all eight cores. Since the available number of
unique interrupts (4) is less than the number of available cores (8), the platform cannot take
advantage of all the available cores for interrupt distribution. However, the Intel® 5000 Series
Chipsets provides an interrupt scaling feature called Fake MSI to mitigate this problem.
3.2.17.1 Overview of Fake MSI Support
All PCIe devices are required to support MSI (Message Signaled Interrupt). In this scheme, the
device causes an interrupt by writing the value of the MSI data register to the address contained
in the MSI address register. The resulting memory write transaction is translated through chipset
logic into an interrupt transaction for the appropriate target processor core(s). However, the MSI
scheme requires support in the OS which is not widely available in currently shipping operating
systems. The Fake MSI scheme allows PCIe devices running on such legacy operating systems
to use the MSI mechanism to generate INTx compatible interrupts. This is accomplished by
targeting the MSI memory write to an IOxAPIC in the system.
Under the Fake MSI scheme, PCI-Express devices are programmed to enable MSI functionality,
and given a write path directly to the pin assertion register (PAR) of an IOxAPIC already present
in the platform. The targeted IOxAPIC will now generate an APIC interrupt message in response
to a memory write to the PAR, thus providing equivalent functionality to a virtual (edge-
triggered) wire between the PCI-Express endpoint and the IOxAPIC. The Intel® 5000 Series
Chipsets ensure that PCI ordering rules are maintained for the Fake MSI memory write.
All PCI-Express devices are required to support MSI. When Fake MSI is enabled, the PCI-
Express devices generate a memory transaction with an address equal to I/OxAPIC_MEM_BAR
+ 0x20 (PAR) and a 32-bit data equal to the interrupt vector number corresponding to the
device. This information is stored in the device's MSI address and data registers, and would be
initialized by the system firmware (BIOS) prior to booting a non-MSI aware operating system.
30 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.2.17.2 Fake MSI Scheme Limitations
The following limitations of the Fake MSI Scheme should be understood before using it in a
platform:
1. The Fake MSI scheme can only be used by IO devices that support MSI capability (all
PCIe devices are required to support either MSI or MSI-X).
1
2. The Fake MSI scheme cannot be used with a device that supports MSI-X (i.e., the
device supports MSI-X only and does not support MSI).
3. The Fake MSI scheme can be used with MSI capable devices only. It cannot be used
with a device that only supports MSI-X.
4. The I/OxAPIC interrupt used for Fake MSI cannot be shared. This is because MSI is an
edge triggered mechanism and sharing will result in loss of interrupts.
5. Even if the IO device is multiple message capable, firmware must program the device to
allocate one vector only (the Fake MSI scheme cannot support MSI multiple messages).
This is required in order to ensure that the device-function does not modify any bits of
the message data field.
6. Each IO device that intends to use the Fake MSI scheme should be programmed to a
unique MSI data value corresponding to a unique I/OxAPIC input. The MSI address
remains the same as we are targeting the PAR of the ESB2 I/OxAPIC.
7. If the IO device generates interrupts for multiple internal events, the device driver ISR
2
must check for all internal events on each interrupt . Otherwise, overrun situations are
possible.
8. In case of multi-function devices, the Fake MSI scheme can be used to support up to 4
functions only. This is because interrupt routing of devices using the Fake MSI scheme
are exposed to the operating system using MPS1.4 or _PRT table; these firmware tables
are limited to 4 unique interrupts per device as required by the PCI Specification.
3.2.18 Acoustical Fan Speed Control
The processors implement a methodology for managing processor temperatures that supports
acoustic noise reduction through fan speed control. There are two components to the
temperature calculation used to regulate the fans: TCONTROL offset and TCONTROL base. The
BIOS retrieves the TCONTROL offset from a processor MSR and sends it to the BMC. The BMC
is responsible for getting the TCONTROL base from the sensor data records and adding it to the
value received from the BIOS.
1
MSI-X requires BAR registers to be initialized to locate the MSI-X table in MMIO space. Since legacy operating
systems could potentially reconfigure the device and its BARs, in the case of “Fake MSI”, there is a risk of losing the
MSI-X programming done by the BIOS.
2
The concern here is that a device driver written with level triggered semantics in mind may dismiss the interrupt with
processing all the internal events associated with the interrupt because it is assured that the interrupt will be
reasserted as long as internal events are pending.
Revision 1.3 31
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3.3 Memory
®
The Intel 5000 MCH supports fully-buffered DIMM (FBDIMM) technology. The integrated
®
Memory Controller Hub in the Intel 5000 MCH divides the FBDIMMs on the board into two
autonomous sets called branches. Each branch has two channels. In dual-channel mode,
FBDIMMs on adjacent channels work in lock-step to provide the same cache line data, and a
combined ECC. In the single-channel mode, only Channel 0 is active.
The BIOS is able to configure the memory controller dynamically in accordance with the
available FBDIMM population and the selected RAS (reliability, availability, serviceability) mode
of operation.
3.3.1 Memory Sizing and Configuration
The BIOS supports various memory module sizes and configurations. These combinations of
sizes and configurations are valid only for FBDIMMs approved by Intel. The BIOS reads the
Serial Presence Detect (SPD) SEEPROMs on each installed memory module to determine the
size and timing characteristics of the installed memory modules (FBDIMMs). The memory-sizing
algorithm then determines the cumulative size of each row of FBDIMMs. The BIOS programs
the memory controller in the chipset accordingly, such that the range of memory accessible from
the processor is mapped into the correct FBDIMM or set of FBDIMMs.
3.3.2 POST Error Codes
The range {0xE0, 0xEF} of POST codes is used for memory errors in early POST. In late POST,
this range is used for reporting other system errors.
If no memory is available, the system will emit POST Diagnostic LED code 0xE1 and
halt the system.
If the system is unable to communicate with the FBDIMMs, the BIOS will eventually time
out and report POST Diagnostic LED code 0xE4. This is usually indicative of hardware
failure.
If a FBDIMM or a set of FBDIMMs on the same FBD memory channel (row) fails Memory
® ®
Intel Interconnect built in self test (Intel IBIST), or Memory Link Training, the BIOS will
emit POST Diagnostic LED code 0xE6. If all of the memory fails IBIST the system will
act as if no memory is available.
Any of the above errors cause a memory error beep code. Memory beep code errors are
described in Section 5.3.2, POST Code Checkpoints.
3.3.3 Publishing System Memory
The BIOS displays the total memory of the system during POST if the display logo is
disabled in the BIOS Setup utility. Total memory is the total size of memory discovered
by the BIOS during POST, and is the sum of the individual sizes of installed FBDIMMs.
The total memory is also displayed on the main page of the BIOS Setup utility.
The BIOS displays the effective memory of the system in the BIOS Setup utility.
Effective memory is the total size of all FBDIMMs that are active (not disabled) and not
used as redundant units.
32 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
If the Display Logo is disabled, the BIOS displays the total system memory on the
diagnostic screen at the end of POST. This total is the same as the amount described by
the first bullet, above.
The BIOS provides the total amount of memory in the system by supporting the EFI Boot
Service function GetMemoryMap().
The BIOS provides the total amount of memory in the system by supporting the INT 15h,
E820h function. See the Advanced Configuration and Power Interface Specification,
Revision 2.0 for details.
Note: Memory between 4 GB and 4 GB minus 1.5 GB is not accessible for use by the operating
system and may be lost to the user. This area is reserved for BIOS, APIC configuration space,
and virtual video memory space. See section 3.3.3.1. Memory will also be reserved for PCI /
PCI Express* / PCI Express resources. This means that if 4 GB of memory is installed, 2.5 GB
or less of this memory is usable. The chipset allows remapping unused memory above the 4 GB
address. To take advantage of this, turn on Physical Address Extensions (PAE) in your
operating system.
3.3.3.1 Memory Reservation for Memory-mapped Functions
A region of size 0.25 GB of memory below 4 GB is always reserved for mapping chipset,
processor and BIOS (flash) spaces as memory-mapped I/O regions. This region will appear as
a loss of memory to the operating system. In addition to this loss, the BIOS creates another
reserved region for memory-mapped PCI Express* functions, including a standard 0.25 GB of
standard PC Express configuration space. This memory is reclaimed by the operating system if
PAE is turned on in the operating system.
3.3.3.2 High-Memory Reclaim
When 4 GB or more of physical memory is installed, the reserved memory is lost. However, the
®
Intel 5000 Series Chipset provides a feature called high-memory reclaim that allows the BIOS
and the operating system to remap the lost physical memory into system memory above 4 GB.
The system memory is the memory that can be seen by the processor.
The BIOS will always enable high-memory reclaim if it discovers installed physical memory
equal to or greater than 4 GB. For the operating system, the reclaimed memory is recoverable
only when it supports and enables the PAE feature in the processor. Most operating systems
support this feature. See the relevant operating system manuals for operating system support in
your environment.
3.3.3.3 Memory Interleaving
In general, to optimize memory accesses, the BIOS will enable Branch Interleaving, which
allows the chipset to interleave data for successive cache-lines between the autonomous
branches. Branch Interleaving is not possible on some platforms, since these do not have
Branch 1 enabled.
®
Additionally, the Intel 5000 sequence MCH also provides interleaving across logical memory
devices called ranks. A pair of single-ranked lock-stepped FBDIMMs constitutes a memory rank.
Interleaving effected between ranks allows the chipset to interleave cache-line data between
Revision 1.3 33
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
participant ranks, and the process is called Rank Interleaving. The BIOS by default enables 4:1
Rank Interleaving, in which 4 ranks participate in a single cache-line access.
3.3.4 Mixed Speed Memory Modules
The BIOS supports memory modules of mixed speed through a combination of user-selected
input frequency and the capability of each memory module (FBDIMM). This section describes
the expected outcome on installation of FBDIMMs of different frequencies in the system, for a
given user-selected frequency.
3.3.4.1 FBDIMM Characteristics
To program a FBDIMM to function correctly for a given frequency, the BIOS queries each
FBDIMM’s Serial-presence Data (SPD) store. The SPD contains the frequency characteristics
of the FBDIMM, which are measured in terms of the following parameters:
CAS latency (CL)
Common clock frequency
Additive latency (AL)
Buffer read delay (BRD)
The CAS latency and the additive latency are configurable parameters that are detected by the
BIOS by reading the SPD data of the FBDIMMs. The BRD is the average inherent delay that is
caused by the finite time that the AMB consumes in buffering the data read from the DRAMs
before forwarding it on the northbound or southbound path.
3.3.4.2 Host Frequency and Gear Ratio
®
The host frequency is the speed of the memory interface of the Intel 5000 Series Chipset. This
frequency determines the speed at which the chipset completes a memory transaction. The
gear ratio determines the relative speed between the processor interface and the memory
interface.
The BIOS supports two frequencies: 533 MHz and 667 MHz. The BIOS also provides an auto-
select feature that provides automatic selection and configuration of the host frequency and
gear ratio.
During memory discovery, the BIOS keeps track of the minimum latency requirements of each
installed FBDIMM by recording relevant latency requirements from each FBDIMM’s SPD data.
The BIOS then arrives at a common frequency that matches the requirements of all components
and then configures the memory system, as well as the FBDIMMs, for that common frequency.
3.3.5 Memory Test
3.3.5.1 Integrated Memory BIST Engine
®
The Intel 5000 MCH incorporates an integrated Memory Built-in Self Test (BIST) engine that is
enabled to provide extensive coverage of memory errors at both the memory cell level, as well
as the data paths emanating from the FBDIMMs.
34 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
The BIOS uses this in-built Memory BIST engine to perform two specific operations:
ECC fill to set the memory contents to a known state. This provides a bare minimum
error detection capability, and is referred to as the Basic Memory Test algorithm.
Extensive FBDIMM testing to search for memory errors on both the memory cells and
the data paths. This is referred to as the Comprehensive Memory Test algorithm.
The Memory BIST engine replaces the traditional BIOS-based software memory tests. The
Memory BIST engine is much faster than the traditional memory tests. The BIOS also uses the
Memory BIST to initialize memory at the end of the memory discovery process. The BIOS does
not execute Memory BIST when the system is waking from an S3 sleep mode (S3 Resume) for
systems that support S3.
3.3.6 Memory Scrub Engine
®
The Intel 5000 MCH incorporates a memory scrub engine. When this integrated component is
enabled, it performs periodic checks on the memory cells, and identifies and corrects single-bit
errors. Two types of scrubbing operations are possible:
Demand scrubbing – executes when an error is encountered during a normal read/write
of data.
Patrol scrubbing – proactively walks through populated memory space seeking soft
errors.
The BIOS enables both demand scrubbing and patrol scrubbing by default.
Demand scrubbing is not possible when memory mirroring is enabled. Therefore, the BIOS will
disable it automatically if the memory is configured for mirroring.
3.3.7 Memory Map and Population Rules
The nomenclature to be followed for DIMM sockets is as follows.
DIMM Socket Branch Channel
DIMM_A1 0 A
DIMM_A2 0 A
DIMM_B1 0 B
DIMM_B2 0 B
DIMM_C1 1 C
DIMM_C2 1 C
DIMM_D1 1 D
DIMM_D2 1 D
Note: Memory map and population rules may vary by product. See the server or workstation
Technical Product Specification that applies to your product for more detailed information.
Revision 1.3 35
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3.3.7.1 Memory Sub-system Nomenclature
FBDIMMs are organized into physical slots on memory channels that belong to memory
branches.
Each branch can support a maximum of four DIMM sockets per channel.
The memory channels are identified as Channel A, B, C, and D.
Channels A and B belong to Branch 0. Channels C and D belong to Branch 1.
The DIMM identifiers on the silkscreen on the board provide information about which
channel, and therefore which branch, they belong to. For example, DIMM_A1 is the first
slot on Channel A on Branch 0. DIMM_C1 is the first DIMM socket on Channel C on
Branch 1.
3.3.7.2 Memory Upgrade Rules
Upgrading the system memory requires careful positioning of the FBDIMMs, based on the
following factors:
The current mode of operation
The existing FBDIMM population
The FBDIMM characteristics
The optimization techniques used by the Intel® 5000 MCH to maximize FBD bandwidth.
In dual-channel mode, the adjacent channels of a branch work in lock-step to provide increase
in FBD bandwidth. Channel A and Channel B are lock-stepped when Branch 0 is configured to
support dual-channel mode, Channel C and Channel D are lock-stepped when Branch 1 is
configured for lock-step.
In single-channel mode, only Channel A, Branch 0 can be active. In this mode, Branch 1 is
always disabled. Accordingly, only FBDIMMs on Channel A are enabled. All other FBDIMMs are
disabled.
The following are the general rules to be observed when selecting and configuring memory to
obtain the best performance from the system.
Rule 1: the Dual-channel or lock-stepped mode of operation is always the preferred
mode of operation, irrespective of the branch on which it is possible.
Rule 2: Branch 0 is usually given precedence over Branch 1 in determining the mode of
operation. The only exception to this rule is when Branch 1 satisfies Rule #1 above, but
Branch 0 cannot.
Rule 3: Both branches are autonomous and capable of being independently initialized.
However, the minimal upgrade for Branch 1 is DIMM_C1/DIMM_D1 such that Rule #1 is
satisfied.
Rule 4: If an installed FBDIMM has faulty or incompatible SPD data, it will be ignored
during the lock-step selection process, and thus essentially disabled by the BIOS. If the
FBDIMM has no or missing SPD information, the slot on which it is placed will be treated
as empty by the BIOS.
36 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Rule 5: The FBDIMM population of Slot 1 on Branch 0 determines the mode that is
selected. If DIMM_A1 and DIMM_B1 cannot lock-step, then the system reverts to single-
channel mode, with DIMM_B1 disabled.
Rule 6: As long as Branch 1 cannot satisfy Rules 1 or 2, the Single-channel mode is
always given preference over dual-channel mode if the configuration on Slot 1, Branch 0
is not in balance (if DIMM_A1 and DIMM_B1 are not identical.)
Rule 7: DIMM_A1 must always be populated, except the special case mentioned in
Rule 2. In addition, the BIOS will always select the mode of operation that best matches
the requirements of DIMM_A1, such that it is always enabled and used for runtime
memory. For example, in a FBDIMM population that has Branch 0 with only DIMM_A1
populated, the BIOS will forcibly initialize and configure single-channel mode with only
DIMM_A1 enabled, regardless of the number of FBDIMMs populated on Branch 1. Such
a method of upgrading system memory is, therefore, incorrect, and results in a reduced-
capacity operation. It must, therefore, be avoided.
Rule 8: DIMM_A1 is the minimum possible FBDIMM configuration. In this configuration,
the memory operates in single-channel mode, and no RAS features are possible.
Rule 9: The minimum memory population recommended by Intel for enabling Branch 1
is four FBDIMMs: DIMM_A1, DIMM_B1, DIMM_C1 and DIMM_D1.
Rule 10: For a branch to operate in lock-step (dual-channel mode), the FBDIMMs in
socket positions on adjacent channels of the branch must be identical in terms of timing,
technology, and size. Therefore, DIMM_A1 and DIMM_B1 must be identical for Branch 1
to work in dual-channel mode.
If the FBDIMMs on adjacent channels of a branch are not identical, the FBDIMM on the
higher channel is disabled.
Rule 11: FBDIMMs on adjacent slots on the same channel do not need to be identical.
Rule 12: The minimum memory upgrade for memory mirroring is four FBDIMMs:
DIMM_A1, DIMM_B1, DIMM_C1 and DIMM_D1. Memory mirroring inherently relies on
the dual-channel mode of operation.
Rule 13: The minimum population for memory pair sparing is four FBDIMMs in dual
channel mode: DIMM_A1, DIMM_A2, DIMM_B1, and DIMM_B2.
Rule 14: Once the FBDIMMs installed on the adjacent channels of a branch have lock-
stepped, the resultant FBDIMM pair is treated as a single “logical” device thereafter.
Therefore, if one of the DIMMs in this lock-stepped pair fails Memory BIST or Channel
IBIST during POST, the BIOS will disable both FBDIMMs of the logical combination.
Similarly, if one of these DIMMs has a runtime transient uncorrectable error, both DIMMs
will be simultaneously disabled.
During the memory discovery phase of POST, the BIOS will disable any FBDIMM that does not
conform to the rules.
®
For platforms that support only a single FBD branch, such as the Intel Server Board
S5000VSA, the same rules are applicable, except for rules that pertain to Branch 1.
3.3.7.3 Examples of FBDIMM Population and Upgrade Rules
See the server or workstation Technical Product Specification that applies to your product for
detailed information on FBDIMM population and upgrade rules.
Revision 1.3 37
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3.3.8 Memory Modes of Operation
Based on the available FBDIMM population, the BIOS will configure the system memory into the
best possible configuration. Possible configurations in RAS mode are:
Single-channel mode
Maximum interleave mode (dual-channel mode)
Memory mirroring mode
DIMM sparing mode (dual or single FBDIMM)
Single-channel and dual-channel modes are special cases when RAS is disabled. In single-
channel mode, only one channel is active on each branch, with the adjacent channel disabled.
In dual-channel mode, the FBDIMMs on adjacent channels on each branch are configured for
maximum interleave in order to provide the optimal lock-step operation.
3.3.9 Memory RAS
3.3.9.1 RAS Features
®
Server boards based on the Intel 5000 Series Chipsets support the following memory RAS
features:
Memory mirroring
Memory sparing
Automatic thermal throttling
® ®
Fully-buffered DIMM (FBD) Channel Intel Interconnect BIST (Intel IBIST)
These standard RAS modes are used in conjunction with the standard memory test and
memory scrub engines to provide full RAS support. Some of the RAS features are implemented
differently on some boards.
3.3.9.2 Memory Sparing
®
All versions of the Intel 5000 Series Chipset provide memory sparing capabilities. Sparing is a
RAS feature that involves configuring of a FBDIMM on the server board to be placed in reserve
so it can be use to replace an FBDIMM that fails.
Spared memory configurations do not provide redundant copies of memory and the system can
not continue to operate when an uncorrectable error occurs. The purpose of memory sparing is
to detect a failing FBDIMM before it causes a system crash. Once the affected FBDIMM is
isolated and removed from the set of active FBDIMMs, the system integrity is maintained by
copying the data from the failed FBDIMM to the reserved FBDIMM.
See Section 3.7.2.1.2 for BIOS Setup utility options to enable this feature. The BIOS Setup
utility will show if memory sparing is possible with the current memory configuration.
Note: The DIMM sparing feature requires that the spare FBDIMM be at least the size of the
largest primary FBDIMM in use. When sparing is enabled, the BIOS selects the spare
automatically during POST. No manual configuration of this feature is required beyond turning
38 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
on the feature in BIOS Setup. With sparing enabled, the total effective memory size will be
reduced by the size of the spare FBDIMM(s).
3.3.9.2.1 Dual-ranked DIMM Sparing
When a dual-ranked FBDIMM is used as a spare, the BIOS has the ability to independently
select a physical rank on that FBDIMM as the spare unit and utilize the other physical rank as a
normal unit. This selective sparing ensures maximization of available memory while still
providing RAS. However, populating differently-ranked FBDIMMs for sparing is not a good
practice and may yield unpredictable results.
3.3.9.3 Minimum FBDIMM Population for Sparing
For FBDIMM sparing, the minimum population is at least two FBDIMMs on the same channel on
any branch. Selecting sparing from BIOS Setup will cause the BIOS to attempt enabling the
feature on both branches to begin with, but actual configuration for a given branch will depend
upon the population of FBDIMMs on that branch.
For example: Correct configurations for Branch 0 are DIMM A1, DIMM A2. An incorrect
configuration for Branch 0 is DIMM A1. Because there is only one FBDIMM, none is available to
act as a spare.
The spare FBDIMMs do not contribute to available physical memory under normal system
operation. The Effective Memory field on the BIOS Setup utility screen will indicate this absence
of memory for the sparing operation.
3.3.9.4 Memory Mirroring
Unlike memory sparing, the mirrored configuration is a redundant image of the memory, and
can continue to operate with some uncorrectable errors occur.
Memory mirroring is a RAS feature in which two identical images of memory data are
®
maintained, providing maximum redundancy. On the Intel 5000 MCH-based Intel server
boards, mirroring is achieved across Branch 0 and Branch 1 such that one of these branches is
the primary image and the other the secondary image. The memory controller always directs
read transactions to the primary branch. Write transactions are directed to both branches under
normal circumstances.
Because the available system memory is divided into a primary image and a copy of the image,
the effective system memory is reduced by one-half. For example, if the system is operating in
memory mirroring mode and the total size of the FBDIMMs is 1 GB, then the effective size of the
memory is 512 MB because half of the FBDIMMs are the secondary images.
For memory mirroring to work, participant FBDIMMs on the same DIMM sockets on the adjacent
branches must be identical in terms of technology, number of ranks, timing, and size.
The BIOS provides a setup option to enable memory mirroring. When memory mirroring is
enabled, the BIOS attempts to configure the memory system accordingly. If the FBDIMM
population is not suitable for mirroring, the BIOS disables mirroring and reverts to the default
non-RAS mode with maximum interleave, or to the single channel mode. The BIOS setup then
defaults to the eventual setting on the next boot.
Revision 1.3 39
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
See the server or workstation Technical Product Specification that applies to your product for
more information.
3.3.9.4.1 Minimum FBDIMM Population for Mirroring
Memory mirroring requires the following minimum requirements:
Branch configuration: Mirroring requires both branches to be active.
Interleave configuration: Mirroring requires that interleaving at the channel level be
enabled on both branches such that the FBDIMMs on the adjacent channels work in
lock-step.
As a direct consequence of these requirements, the minimum FBDIMM population is DIMM_A1,
DIMM_B1, DIMM_C1, and DIMM_D1. For more information, see section 3.3.7.
In this mode the pair of DIMM A1 and DIMM B1, and the pair of DIMM_C1 and DIMM_D1
operate in lock-step on Branch 0 and Branch 1 respectively, meeting the requirements listed
above. Therefore, the minimum number of FBDIMMs for mirroring is four, arranged as
mentioned above. The BIOS will disable all non-identical FBDIMMs, or pairs of FBDIMMs,
across the branches to achieve symmetry and balance between the branches.
3.3.9.5 Automatic Thermal Throttling
®
The Intel 5000 sequence MCH performs automatic electrical throttling on the FBDIMMs when
there is heavy memory traffic, as in the case of a memory intensive application, which indirectly
results in a rise in temperature of the advanced memory buffers (AMBs) on the FBDIMMs. The
BIOS always enables electrical throttling.
The BIOS will send a command to the BMC telling it which fan profile is set in BIOS Setup
(acoustic or performance) and then it will send an additional command to get the settings for
that profile. The BIOS uses the parameters retrieved from the thermal sensor data records
(SDR) and the altitude setting from BIOS Setup to configure the memory and the chipset for
memory throttling and fan speed control. If the BIOS fails to get the thermal SDRs, then it will
use the memory reference code (MRC) default settings for the thermal values.
3.3.10 Memory Error Handling
This section describes the BIOS and chipset policies used for handling and reporting errors
occurring in the memory sub-system.
3.3.10.1 Memory Error Classification
The BIOS classifies memory errors into the following categories:
Correctable ECC errors: errors that occur in memory cells and result in corruption of
memory, but are internally corrected by the ECC engine in the chipset.
Uncorrectable ECC errors: errors that occur in memory cells and result in data
corruption. The chipset’s ECC engine detects these errors, but cannot correct them.
These errors create a loss of data fidelity and are severe errors.
40 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Unrecoverable and Fatal Errors: errors that are outside of the scope of the standard
ECC engine. These errors are thermal errors, FBD channel errors and data path errors.
These errors bring about catastrophic failure of the system.
There are two specific stages in which memory errors can occur:
Early POST, during memory discovery
Late POST, or at runtime, when the operating system is running
During POST, the BIOS will capture and report memory BIST errors.
Memory RAS configuration errors
At runtime, the BIOS will capture and report correctable, uncorrectable, and fatal errors
occurring in the memory sub-system.
Loss of memory RAS functionality
3.3.10.1.1 Faulty FBDIMMs
The BIOS provides detection of a faulty or failing FBDIMM. An FBDIMM is considered faulty if it
®
fails the memory BIST. The BIOS enables the in-built memory BIST engine in the Intel 5000
Series Chipsets during memory initialization in POST. The memory BIST cycle isolates failed,
failing, or faulty FBDIMMs and the BIOS then marks those FBDIMMs as failed and takes these
FBDIMMs off-line.
FBDIMMs can fail during normal operation. The BIOS marks these FBDIMMs as temporarily
disabled, and performs other housekeeping tasks as relevant. The memory BIST function is
performed on every FBDIMM during each boot of the system, unless waking from S3.
3.3.10.1.2 Faulty Links
FBDIMM technology is a serial technology. Therefore, errors or failures can occur on the serial
path between FBDIMMs. These errors are different from ECC errors, and do not necessarily
occur as a result of faulty FBDIMMs. The BIOS keeps track of such link-level failures.
In general, when a link failure occurs, the BIOS will disable all FBDIMMs on that link. If all
FBDIMMs are present on the same faulty link, the BIOS will generate POST code 0xE1 to
indicate that the system has no usable memory, and then halts the system.
If a link failure occurs during normal operation at runtime (after POST), the BIOS will signal a
fatal error and perform policies related to fatal error handling.
3.3.10.1.3 Error Counters and Thresholds
The BIOS handles memory errors thru a variety of platform-specific policies. Each of these
policies is aimed at providing comprehensive diagnostic support to the system administrator
towards system recovery following the failure.
Revision 1.3 41
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
®
The BIOS uses error counters on the Intel 5000 Series Chipsets and internal software counters
to track the number of correctable and Multi-bit correctable errors that occur at runtime. The
chipset increments the count for these counters when an error occurs. The count also decays at
a given rate, programmable by the BIOS. Because of this particular nature of the counters, they
are termed leaky bucket counters.
The leaky bucket counters provide a measurement of the frequency of errors. The BIOS
configures and uses the leaky bucket counters and the decay rate such that it can be notified of
a failing FBDIMM. A failing FBDIMM will typically generate a burst of errors in a short period of
time, which is detected by the leaky bucket algorithm. The chipset maintains separate internal
leaky bucket counters for correctable and multi-bit correctable errors respectively.
The BIOS initializes the correctable error leaky bucket counters to a value of 10 for correctable
ECC errors. These counters are on a per-rank basis. A rank applies to a pair of FBDIMMs on
adjacent channels functioning in lock-stepped mode.
3.3.10.1.3.1 BIOS Policies on Correctable Errors
For each correctable error that occurs before the threshold is reached, the BIOS will log a
Correctable Error SEL entry. No other action will be taken, and the system will continue to
function normally.
When the error threshold reaches 10, the BIOS logs a SEL entry to indicate the correctable
error. In addition, the following steps occur:
1. If sparing is enabled, the chipset initiates a spare fail-over to a spare FBDIMM. In all
other memory configurations, Future correctable errors are masked and no longer
reported to the SEL.
2. The BIOS logs a Max Threshold Reached SEL event.
3. The BIOS sends a DIMM Failed event to the BMC. This causes the BMC to light the
system fault LEDs to initiate memory performance degradation and an assertion of the
failed FBDIMM.
4. The BMC lights the DIMM fault LED for the faulty FBDIMM.
3.3.10.1.4 Multi-bit Correctable Error Counter Threshold
Due to the internal design of the chipset, the same threshold value for correctable errors also
applies to the multi-bit correctable errors. However, maintaining a tolerance level of 10 for multi-
bit correctable errors is undesirable because these are critical errors. Therefore, the BIOS
programs the threshold for multi-bit correctable errors based on the following alternate logic:
Automatic retries on memory errors: The chipset automatically performs a retry of
memory reads for uncorrectable errors. If the retry results in good data, this is termed a
multi-bit correctable error. If the data is still bad, then it is an uncorrectable error, if
memory controller is not configured to memory mirroring mode. The retry eliminates
transient CRC errors that occur on memory packets transacted over the FBDIMM serial
links between the chipset and the FBDIMMs.
Internal error reporting by the chipset: The chipset records the occurrence of
uncorrectable errors both at the time of the occurrence, and on the subsequent failure
on retry. Both errors are independently reported to the BIOS. The BIOS will report a
42 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
successful retry as “Correctable Memory Error” in the SEL regardless of whether the
originating error was a CRC error or an ECC error.
3.3.10.1.5 FBD Fatal Error Threshold
In addition to standard ECC errors, the BIOS monitors FBD protocol errors reported by the
chipset. FBD protocol errors cause degradation of system memory, and hence it is pointless to
tolerate them to any level. The BIOS maintains an internal software counter to handle FBD
errors. The threshold of this software counter is 1.
3.3.10.1.5.1 BIOS Policies on Uncorrectable Errors
For uncorrectable errors, the BIOS will log a single Uncorrectable Error SEL entry. The BIOS
generates an NMI.
3.3.10.1.6 Error Period
The error period, or decay rate, defines the rate at which the leaky bucket counter values are
decremented. The decay period is the time period for the leaky bucket count to decay to 0.
Since the frequency of errors is directly related to the size of the FBDIMMs, the BIOS uses the
information in the following table to define the optimal period:
FBDIMM Decay Period
Size (Approximate Duration)
512 MB 9 days
1 GB 9 days
2 GB 9 days
4 GB 7 days
3.3.10.1.7 Retry on Error
®
The Intel 5000 MCH will issue a retry on all failures. In mirroring mode, the read transactions
occur on the primary image only. Write transactions are issued to both images. The behavior of
the chipset on encountering an error depends on the transaction in which the error was first
detected.
When the chipset encounters an uncorrectable error on Branch X, it issues a retry on
Branch Y. If the retry succeeds, it corrects the data on both branches and proceeds
normally.
If the retry from the other branch also fails, and if both branches fail on retry, then the
chipset will reset both branches and report a fatal error to the BIOS.
Revision 1.3 43
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3.3.10.2 Memory Error Reporting
Memory errors are reported through a variety of platform-specific elements, as described in this
section.
Platform Element Description
Event Logging When a memory error occurs at runtime, the BIOS will log the error into the system
event log in the BMC repository.
BIOS Diagnostic / Error At the end of POST, memory errors found during MemBIST are reported in the
Screen BIOS Error Manager.
Beep Codes The BIOS will emit a beep code for the cases where the system has no memory, or
when a link failure is detected during memory discovery, causing all memory to be
mapped out.
BIOS Setup Screen When FBDIMMs fail memory BIST, or RAS configuration errors occur, the FBDIMM
status is captured in the Advanced | Memory screen in BIOS setup.
® ®
DIMM Fault Indicator LEDs Intel server boards and systems that use the Intel 5000 Series Chipsets have a
set of fault indicator LEDs on the board, one LED per DIMM socket. These LEDs
are used for indicating failed/faulty FBDIMMs.
® ®
System Fault/Status LEDs Intel server boards and systems that use the Intel 5000 Series Chipsets provide
a specific LED on the front panel that indicates the state of the system. When a
memory error occurs such that the performance of the memory sub-system is
affected the BIOS will send a request to the BMC to light up the system fault LED.
NMI Generation The BIOS will trigger / initiate an NMI to halt the system when a critical error
occurs.
3.3.10.2.1 Memory Error Logging
Memory error logging involves the BIOS sending the BMC commands to log memory errors in
the system event log (SEL). These error formats are described by the Intelligent Platform
Management Interface Specification, v.2.0.
Sensor Type Sensor Type Code Offset Description
Memory 0x0C 0x08 Memory ECC Error
Memory 0x0C 0x09 Memory ECC Error
Event Data 1
0x20 Correctable ECC Error
0x21 Uncorrectable ECC Error
0x25 Correctable ECC Error Threshold Reached
Event Data 2
0xFF
Event Data 3
®
Bits[7:6] Index into SMBIOS Type16 entry for the system’s Memory Array Device. For Intel server boards
®
and systems that use the Intel 5000 Series Chipsets this shall always be 0 to indicate that a single
on-board memory controller is present.
Bits [5:0] Index into SMBIOS Type17 record for the failed FBDIMM.
44 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.3.10.2.2 Memory BIST Error Reporting
The error manager screen in the BIOS captures memory BIST failures that occurred during the
current POST.
Table 5. Memory Errors Captured by Error Manager
Specific Error Error Class Error Code Error Text Description
Configuration Error Pause 0x85F0 Memory was not Failure of BIOS to configure
configured for the the memory system in the
selected memory RAS selected RAS mode.
mode.
Memory BIST Failure Pause 0x852x DIMM_xx failed self test During normal Memory BIST
(BIST). operation in POST, the BIOS
detected that DIMM_xx failed
to pass Memory BIST.
Note: x = the instance number of the DIMM that failed.
3.3.10.2.3 DIMM Fault Indicator LEDs
®
Intel server boards have a fault-indicator LED next to each DIMM socket. The LEDs are turned
on when the FBDIMM on the adjacent DIMM socket is determined to be faulty.
The generic usage model for the DIMM fault LEDs is as follows:
Table 6. DIMM Fault Indicator LEDs
Error Event Mode of Operation Description
A FBDIMM fails memory BIST during N/A DIMM LED for the FBDIMM lights.
POST.
®
Channel Intel IBIST failure occurs N/A If there are multiple FBDIMMs on
during POST. that channel, all corresponding
DIMM LEDs light.
Correctable error threshold reached for System is operating in single- DIMM fault LED for the failed
a failing FBDIMM. (Ten correctable channel mode. FBDIMM lights on the error count
errors occur on the same FBDIMM reaching the threshold, (on the 10th
within the limits of the error period) error).
Correctable error threshold reached for System is operating in dual-channel DIMM fault LEDs of both FBDIMMs
a failing FBDIMM. (Ten correctable mode. of the lock-stepped pair light up on
errors occur on the same FBDIMM the error count reaching the
within the limits of the error period) threshold, (on the 10th error).
Uncorrectable error occurs on a System is operating in single- DIMM fault LED for the failed
FBDIMM. channel mode. FBDIMM lights up.
Uncorrectable error occurs on a System is operating in dual-channel DIMM fault LEDs for the failed pair
FBDIMM. mode. of FBDIMMs light.
Fatal channel link-level or FBD error N/A DIMM fault LEDs of all FBDIMMs
occurs. present on the channel or branch
lights.
Revision 1.3 45
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Note: As indicated in the above table, when two FBDIMMs operate in lock-stepped mode. If one
of the FBDIMMs fails, the BIOS will also light the DIMM fault LED of the companion FBDIMM.
This is because the BIOS cannot isolate failures at the individual FBDIMM level in this mode. In
all cases the BMC will light the LEDs after receiving IPMI messages from the BIOS.
3.3.10.2.4 System Status Indicator LEDs
Intel server boards have a system status indicator LED on the front panel. This indicator LED is
used to indicating many different system errors. The table below shows the policies that are
specific to memory errors.
Table 7. System Status Indicator LEDs
Color State Criticality Description
Off N/A Not ready AC power off
Green / Alternating Not ready Pre DC power on – 15-20 second BMC initialization when AC is
Amber Blink applied to the server. Control panel buttons are disabled until BMC
initialization is complete.
Green Solid on System OK System booted and ready.
Green Blink Degraded System degraded
Unable to use all of the installed memory (more than one DIMM
installed).
Correctable errors over a threshold of 10 and migrating to a
spare DIMM (memory sparing). This indicates that the user no
longer has spared DIMMs indicating a redundancy lost
condition. Corresponding DIMM LED should light up.
In mirrored configuration, when memory mirroring takes place
and system loses memory redundancy.
Redundancy loss such as power-supply or fan. This does not
apply to non-redundant sub-systems.
PCI-e link errors
CPU failure / disabled – if there are two processors and one of
them fails
Fan alarm – Fan failure. Number of operational fans should be
more than minimum number needed to cool the system
Non-critical threshold crossed – Temperature and voltage
Amber Blink Non-critical Non-fatal alarm – system is likely to fail
Critical voltage threshold crossed
VRD hot asserted
Minimum number of fans to cool the system not present or
failed
In non-sparing and non-mirroring mode if the threshold of ten
correctable errors is crossed within the window
Amber Solid on Critical, non- Fatal alarm – system has failed or shutdown
recoverable DIMM failure when there is one DIMM present, no good
memory present
Run-time memory uncorrectable error in non-redundant mode
IERR signal asserted
Processor 1 missing
Temperature (CPU ThermTrip, memory TempHi, critical
threshold crossed)
No power good – power fault
Processor configuration error (for instance, processor stepping
mismatch)
46 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
The LEDs are controlled by the BMC, but the BIOS informs the BMC of the memory errors that
are described in the table. The methods used to inform the BMC of the error(s) are described
section 3.3.10.2.1. It is the responsibility of the BMC to modify the LED behavior according to
the notification received from the BIOS.
3.3.10.2.4.1 System Status LED – BMC Initialization
When the AC power is first applied to the system and 5 V standby is present, the BMC controller
on the server board requires 15-20 seconds to initialize. During this time, the system status LED
blinks, alternating between amber and green, and the power button on the control panel is
disabled, preventing the server from powering up. After BMC initialization has completed, the
status LED will stop blinking and the power button functionality is restored.
3.3.10.2.5 NMI Generation
The BIOS will generate an NMI to halt the system progress when normal memory operations
cannot continue. The following table lists the conditions under which NMI generation occurs.
Table 8. NMI Generation
Error Event Mode of Operation
Uncorrectable error occurs at runtime. Non-RAS (single channel or maximum performance)
or sparing mode or mirroring mode when the primary
and mirror are both bad.
Fatal FBD errors occur at runtime. All modes.
3.3.10.3 Mirroring Mode Errors
When mirroring mode is enabled, the BIOS will report errors in accordance with the following
table:
Table 9. Mirroring Mode Errors
Event Actions
Mirroring mode selected by the user, but the BIOS failed Error message in the error manager at end of POST.
to configure the system in mirroring mode. Error ID 0x85FD
Current Memory Configuration field in the Advanced |
Memory tab in the BIOS Setup utility indicates maximum
performance or single-channel mode, depending upon
the FBDIMM population
Correctable error in the primary or secondary branch. SEL generated with Sensor Offset = Correctable Error.
Number of errors is less than the threshold of 10
Correctable error in primary or seconday branch, number SEL generated with Sensor Offset = Correctable Error
of such errors in the same branch reaches the threshold
SEL generated with Sensor Offset = Correctable Error
of 10.
Threshold
DIMM fault LED for the failed DIMM lights.
First uncorrectable ECC error in primary and secondary SEL generated with Sensor Offset = Uncorrectable Error.
branch
Failed memory is taken off-line.
DIMM fault LED for the failed FBDIMM is lit.
NMI is asserted.
Revision 1.3 47
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 10. POST Memory Error Handling
Scenario POST Message SEL LED State IPMI MEM States System Operation
Updated
POST Memory BIST Uncorrectable error UE POST code DIMM LED: Lit for the DIMM fail status = Y The system continues to boot if
Uncorrectable Error message that failed FBDIMM only. good memory is found. If only bad
DIMM failed POST code Disabled status = Y
(UE) (hard error) identifies FBDIMM memory is found, the system
System fault LED: Not
SEL messages identify
location emits a beep code and displays a
lit.
FBDIMM location
POST diagnostic LED message.
POST Memory FB- Uncorrectable error UE POST code DIMM LED: Lit for all Fail status = Y The system will disable all
®
DIMM Intel IBIST message that identify affected FBDIMMs. FBDIMMs on the FBDIMM
DIMM failed POST code Disabled status = Y
Error FBDIMM location(s) channel that failed. The system
System fault LED: Not
SEL messages identify
will continue to function normally
lit.
FBDIMM location(s)
if there are good FBDIMMs to be
found on the other channel or
branch. The system will light fault
LEDs for all FBDIMMs, starting
from the first, that failed IBIST
irrespecctive of whether these
DIMM sockets are populated or
not. This is to indicative a
broader-level channel or branch
failure.
48 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Table 11. Runtime Memory Error Handling, No Redundancy
Scenario POST Message SEL LED State IPMI MEM States System Operation
Updated
Runtime: None, because the CE SEL message with DIMM DIMM fault LED: Not lit. No The system
BIOS does not retain location continues to
Config != RAS System fault LED: Not lit.
the memory state operate.
Correctable Errors
information across
(CE) < Threshold
reboots.
Runtime: None, because the CE SEL message DIMM LED: Lit for the failed Fail Status = Y The system
BIOS does not retain FBDIMM only. continues to
Config != RAS CE Threshold Reached Disabled Status = N
the memory state operate normally,
message System fault LED:
CE >= Threshold
information across but will mask all
CE Logging Stopped Green / blink: more than
reboots. correctable memory
one FBDIMM installed.
errors.
Amber / on: Only one
FBDIMM is installed.
Runtime: Config != None, because the UE identifying the FBDIMM DIMM fault LED: Lit for the Fail status = Y The system will
RAS UE BIOS does not retain location lockstepped pair or for a single NMI.
Disabled Status = Y
the memory state FBDIMM, depending upon the
information across mode of operation.
reboots.
System fault LED: Amber / on.
Revision 1.3 49
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 12. Runtime Error Handling, with Redundancy
Scenario POST Message SEL LED State IPMI MEM States System Operation
Updated
Runtime: None, because the CE SEL message DIMM fault LED: No The system continues to operate
BIOS does not retain identifying FBDIMM Not lit. normally.
Config = SPARE
the memory state location
System fault LED:
CE < Threshold
information across
Not lit.
reboots.
Runtime: None, because the CE SEL Identifying DIMM fault LED: Fail status = Y The system continues to operate
BIOS does not retain FBDIMM location Lit in lock-stepped normally. System transitions to non-
Config = Spare Disable status = Y
the memory state mode for the failed redudant mode. The BIOS will mask all
Threshold reached SEL
CE >= Threshold Spare status =
information across pair of FBDIMMs. correctable memory errors.
identifying FBDIMM
Spare 1 / 0
reboots.
location In single-channel
RAS Redundancy
mode, lit for the
CE logging stopped
State Redundant /
failed FBDIMM.
Non-redundant
System fault LED:
Green / blink.
Runtime: None, because the UE SEL Identifying DIMM fault LED: Fail status = Y The system will NMI.
BIOS does not retain FBDIMM location Lit if dual-channel
Config = Spare
the memory state mode, for a pair of
Current State: Non-
information across FBDIMMs, else for
Redundant
reboots. a single FBDIMM.
(Post-SFO)
System fault LED:
UE
Amber / on.
Runtime: None, because the UE SEL Identifying DIMM fault LED: Fail status = Y The system will NMI.
BIOS does not retain FBDIMM location Lit if dual-channel
Config = SPARE
the memory state mode, for a pair of
Current State:
information across FBDIMMs.
Redundant
reboots.
Else lit for a single
(Pre-SFO)
FBDIMM.
UE
System fault LED:
Amber / on.
Runtime: None, because the CE SEL Identifying DIMM fault LED: Fail Status = Y Operating system continues to operate
BIOS does not retain FBDIMM location Lit for the failed normally. The BIOS will mask all
Config = MIR Disable Status = N
the memory state pair. correctable errors.
CE Max SEL identifying
Current State:
information across
FBDIMM location System fault LED
Redundant
reboots.
state: Green / blink
CE >= Threshold
50 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Scenario POST Message SEL LED State IPMI MEM States System Operation
Updated
Runtime: None, because the UE SEL message DIMM fault LED: Fail status = Y The system will NMI.
BIOS does not retain identifying FBDIMM Lit for the failed
Config = MIR, Disabled Status = Y for
the memory state location FBDIMM pair.
all FBDIMMs on the
and Current State:
information across
System fault LED: failed branch / group
Redundant
reboots.
Green / blink
UE
Revision 1.3 51
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3.4 Platform Control
This server platform has embedded platform control which is capable of automatically adjusting
system performance and acoustic levels.
Performance Performance
Performance Performance
M Ma an na ag ge em me en nt t T Th hr ro ot tt tlliin ng g
I In nt te eg gr ra at te ed d
Control
Control
Acoustic Thermal
Acoustic Thermal
M Ma an na ag ge em me en nt t M Mo on niit to or riin ng g
Fan Speed
Fan Speed
C Co on nt tr ro oll
Platform control optimizes system performance and acoustics levels through:
Performance management
Performance throttling
Thermal monitoring
Fan speed control
Acoustics management
The platform components used to implement platform control include:
Baseboard management controller functions of the ESB-2
LM94 sensor monitoring chip
Platform sensors
Variable speed system fans
System BIOS
BMC firmware
Sensor data records as loaded by the FRUSDR Utility
FBDIMM type
Processor type
52 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.4.1 FBDIMM Open and Closed Loop Thermal Throttling
Open-Loop Thermal Throttling (OLTT)
Throttling is a solution to cool the DIMMs by reducing memory traffic allowed on the memory
bus, which reduces power consumption and thermal output. With OLTT, the system throttles in
response to memory bandwidth demands instead of actual memory temperature. Since there is
no direct temperature feedback from the Fully Buffered DIMMs (FBD), the throttling behavior is
preset rather than conservatively based on the worst cooling conditions (i.e., high inlet
temperature and low fan speeds). Additionally, the fans that provide cooling to the memory
region is set to conservative settings as well (i.e., higher minimal fan speed). OLTT produces a
slightly louder system than CLTT because minimal fan speeds have to be set high enough to
support any FBDs in the worst memory cooling conditions.
Closed-Loop Thermal Throttling (CLTT)
CLTT works by throttling the FBDs response directly to memory temperature via thermal
sensors integrated on the advance memory buffer (AMB) of the FBD. This is the preferred
throttling method because this approach lowers limitations on both memory power and thermal
threshold, therefore minimizing throttling impact on memory performance. This reduces the
utilization of high fan speeds because CLTT does not have to accommodated for the worst
memory cooling conditions; with a higher thermal threshold, CLTT enables memory
performance to achieve optimal levels. If the thermal sensors do not function properly (i.e,
unable to retrieve memory temperature readings), the system can respond accordingly to
enable either OLTT or CLTT.
Note: CLTT is only supported starting for specific BIOS, BMC and FRUSDR versions. See the
Release Notes for information on the software stack that applies to your product(s).
3.4.2 Fan Speed Control
System fan speed is controlled by the Baseboard Management Controller (BMC) functions of
the ESB-2 chip. During normal system operation, the BMC will retrieve information from BIOS
and monitor several platform thermal sensors to determine the required fan speeds.
In order to provide the proper fan speed control for a given system configuration, the BMC must
have the appropriate platform data programmed. Platform configuration data is programmed
using the FRUSDR Utility during the system integration process, and by System BIOS during
run time.
3.4.2.1 System Configuration Using the FRUSDR Utility
The Field Replaceable Unit & Sensor Data Record Update Utility (FRUSDR utility) is a program
used to write platform specific configuration data to NVRAM on the server board. It allows the
User to select which supported chassis (Intel or Non-Intel) and platform chassis configuration is
being used. Based on the input provided, the FRUSDR writes sensor data specific to the
configuration to NVRAM for the BMC controller to read each time the system is powered on.
3.4.2.2 Fan Speed Control from BMC and BIOS Inputs
Using the data programmed to NVRAM by the FRUSDR utility, the BMC is configured to monitor
and control the appropriate platform sensors and system fans each time the system is powered
on. After power-on, the BMC uses additional data provided to it by System BIOS to determine
how the system fans should be controlled.
Revision 1.3 53
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
The BIOS provides data to the BMC telling it which fan profile the platform is setup for,
Acoustics Mode or Performance Mode. The BIOS uses the parameters retrieved from the
thermal sensor data records (SDR), the fan profile setting from BIOS Setup, and the altitude
setting from BIOS Setup to configure the system for memory throttling and fan speed control. If
the BIOS fails to get the Thermal SDRs, then it will use the Memory Reference Code (MRC)
default settings for the memory throttling settings.
The BIOS Setup Utility provides options to set the fan profile or operating mode the
platform will operate under. Each operating mode has a predefined profile for which specific
platform targets are configured, which in turn determines how the system fans operate to meet
those targets. Platform profile targets are determined by which type of platform is selected when
running the FRUSDR utility and by BIOS settings configured using the BIOS Setup Utility.
3.4.2.3 Configuring the Fan Profile Using the BIOS Setup Utility
The BIOS uses options set in the BIOS Setup Utility to determine what fan profile the
system should operate under. These options include “SET FAN PROFILE” and “ALTITUDE”.
The “SET FAN PROFILE” option can be set to either the “Performance” mode (Default), or
“Acoustics” mode. See the following sections for detail describing the difference between each
mode. Changing the fan profile to Acoustics mode may affect system performance.
The “ALTITUDE” option is used to determine appropriate memory performance settings based
on the different cooling capability at different altitudes. At high altitude, memory performance
must be reduced to compensate for thinner air. Be advised, selecting an Altitude option to a
setting that does not meet the operating altitude of the server may limit the system fans ability to
provide adequate cooling to the memory. If the air flow is not sufficient to meet the needs of the
server even after throttling has occurred, the system may shut down due to excessive platform
thermals.
By default, the Altitude option is set to 301Meters – 900 Meters which is believed to cover the
majority of the operating altitudes for these server platforms.
The following Diagrams show which BIOS Setup Utility menu is used to configure the desired
Fan Profile.
Advanced
System Acoustic and Performance Configuration
Throttling Mode Open Loop / Closed Loop
Set Fan Profile Performance / Acoustics
Altitude 300 M or less / 301 M - 900 M / Higher than 900 M
54 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Setup Item Option Help Text Comments
Throttling Mode Open Loop does not rely on a thermal
Open Loop
sensor on the board and sets up a static
Closed Loop
level which equates to a fixed bandwidth.
Closed Loop will allow the system to
achieve higher performance by monitoring
system temps and adjusting bandwidth.
Set Fan Profile Select the fan control profile that will be Performance mode favors
Performance
used to cool the system. using fans over throttling
Acoustic
memory bandwidth to cool
the system.
Note: This option is only
available when Open Loop
Throttling Mode is selected.
Altitude 300 M or less 300 M or less (<= 980ft): Provides the best
Note: This option is
performance option for servers operating unavailable when the BIOS
301 M - 900 M
at or near sea level. supports Closed Loop
Higher than 900 M
Throttling Mode.
301 M – 900 M (980ft - 2950ft): Provides
the best performance option for servers
operating at moderate altitudes above sea
level.
Higher than 900 M (>2950ft): Provides the
best performance option for servers
operating at high elevations above sea
level.
Note: Fan speed control for non-Intel chassis, as configured after running the FRUSDR utility
and selecting the Non-Intel Chassis option, is limited to only the CPU fans. The BMC only
requires the processor thermal sensor data to determine how fast to operate these fans. The
remaining system fans will operate at 100% operating limits due to unknown variables
associated with the given chassis and its fans. Therefore, regardless of whether the system is
configured for Performance Mode or Acoustics Mode, the System fans will always run at 100%
operating levels providing for maximum airflow. In this scenario the Performance and Acoustic
mode settings only affects the allowable performance of the memory (higher BW for the
Performance mode).
3.4.2.4 Performance Mode (Default)
With the platform running in Performance mode (Default), several platform control algorithm
variables are set to enhance the platform’s capability of operating at maximum performance
targets for the given system. In doing so, the platform is programmed with higher fan speeds at
lower external temperatures. This will result in a louder acoustic level than is targeted for the
given platform, but the increased airflow of this operating mode will greatly reduce possible
memory throttling from occurring and will reduce dynamic fan speed changes based on
processor utilization.
3.4.2.5 Acoustics Mode
With the platform running in Acoustics mode, several platform control algorithm variables are set
to ensure acoustic targets are not exceeded for specified Intel platforms. In this mode, the
platform is programmed to set the fans at lower speeds when the processor does not require
Revision 1.3 55
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
additional cooling due to high utilization / power consumption. Memory throttling will be utilized
to ensure that the memory thermal limits are not exceeded.
3.5 Flash ROM
®
The BIOS supports the Intel 28F320C3 flash part. The flash part is a 4 MB flash ROM, 2 MB of
which is programmable. The flash ROM contains system initialization routines, setup utility, and
runtime support routines. The exact layout is subject to change, as determined by Intel. A 128
KB block is available for storing OEM code (user binary) and custom logos.
3.6 BIOS User Interface
3.6.1 Logo / Diagnostic Screen
The Logo / Diagnostic screen may be in one of two forms. If Display Logo is enabled in the
BIOS Setup utility, a logo splash screen is displayed. By default Display Logo is enabled in
BIOS Setup. If the logo is displayed during POST, pressing will hide the logo and display
the diagnostic screen.
If no logo is present in the flash ROM, or if Display Logo is disabled in the system configuration,
the summary and diagnostic screen is displayed.
The diagnostic screen consists of the following information:
BIOS ID. See Section 3.1
System name
Total memory detected (the total size of all installed FBDIMMs)
Processor information (Intel branded string, speed, and number of physical processors
identified)
Flash bank from which the system is booted
Types of keyboards detected if plugged in (PS/2* and/or USB)
Types of mouse devices detected if plugged in (PS/2 and/or USB)
3.7 BIOS Setup Utility
The BIOS Setup utility is a text-based utility that allows the user to configure the system and
view current settings and environment information for the platform devices. The BIOS Setup
utility controls the platform's built-in devices.
The BIOS Setup utility interface consists of a number of pages or screens. Each page contains
information or links to other pages. The first page in the BIOS Setup utility displays a list of
general categories as links. These links lead to pages containing specific category’s
configuration.
The following sections describe the look and behavior for the BIOS Setup utility.
3.7.1 Operation
The BIOS Setup utility has the following features:
56 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Localization. BIOS Setup uses the Unicode standard and is capable of displaying Setup
pages in all languages currently included in the Unicode standard. However, the Intel
Server Board BIOS is available only in English.
The BIOS Setup utility is functional via console redirection over various terminal
emulation standards. This may limit some functionality for compatibility, such as the use
of colors, some keys or key sequences, or support of pointing devices.
3.7.1.1 Setup Page Layout
The BIOS Setup utility page layout is sectioned into functional areas. Each occupies a specific
area of the screen and has dedicated functionality. The following figure and table lists and
describes each functional area.
Figure 5. General BIOS Screen Display Layout
Revision 1.3 57
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 13. BIOS Setup Page Layout
Functional Area Description
Title Bar The title bar is located at the top of the screen and displays the title of the form
(page) the user is currently viewing. It may also display navigational information.
Setup Item List The setup item list is a set of controllable and informational items. Each item in the
list occupies the left and center columns in the middle of the screen. The left
column, the setup item, is the subject of the item. The middle column, the option,
contains an informational value or choices of the subject.
A setup item can be a hyperlink that is used to navigate pages. When it is a
hyperlink, a setup item only occupies the setup item part of the screen.
Item Specific Help Area The item specific help area is located on the right side of the screen and contains
help text for the highlighted setup item. Help information includes the meaning and
usage of the item, allowable values, effects of the options, etc.
Keyboard Command Bar The keyboard command bar at the bottom right of the screen continuously displays
help for special keys and navigation keys. The keyboard command bar is context-
sensitive—it displays keys relevant to current page and mode.
Status Bar The status bar occupies the bottom line of the screen. This line would displays the
BIOS ID.
3.7.1.2 Entering BIOS Setup
The BIOS Setup utility is started by pressing the key during the system boot when the
OEM or Intel logo is displayed.
When Display Logo is disabled, the following message is displayed on the diagnostics screen:
“press to enter setup”.
3.7.1.3 Keyboard Commands
The bottom right portion of the BIOS Setup utility screen provides a list of commands that are
used to navigate through the utility. These commands are displayed at all times.
Each menu page contains a number of features. Except those used for informative purposes,
each feature is associated with a value field. This field contains user-selectable parameters.
Depending on the security option chosen and in effect by the password, a menu feature’s value
may or may not be changeable. If a value is non-changeable, the feature’s value field is
inaccessible. It displays as “grayed out.”
58 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
The keyboard command bar supports the following:
Table 14. BIOS Setup: Keyboard Command Bar
Key Option Description
Execute The key is used to activate sub-menus when the selected feature is a sub-
Command menu, or to display a pick list if a selected option has a value field, or to select a
sub-field for multi-valued features like time and date. If a pick list is displayed, the
key will select the currently highlighted item, undo the pick list, and return
the focus to the parent menu.
Exit The key provides a mechanism for backing out of any field. This key will
undo the pressing of the Enter key. When the key is pressed while editing
any field or selecting features of a menu, the parent menu is re-entered.
When the key is pressed in any sub-menu, the parent menu is re-entered.
When the key is pressed in any major menu, the exit confirmation window is
displayed and the user is asked whether changes can be discarded. If “No” is
selected and the key is pressed, or if the key is pressed, the user is
returned to where he/she was before was pressed, without affecting any
existing any settings. If “Yes” is selected and the key is pressed, setup is
exited and the BIOS returns to the main System Options Menu screen.
Select Item The up arrow is used to select the previous value in a pick list, or the previous
↑
option in a menu item's option list. The selected item must then be activated by
pressing the key.
Select Item The down arrow is used to select the next value in a menu item’s option list, or a
↓
value field’s pick list. The selected item must then be activated by pressing the
key.
↔ Select Menu The left and right arrow keys are used to move between the major menu pages.
The keys have no affect if a sub-menu or pick list is displayed.
Select Field The key is used to move between fields. For example, can be used
to move from hours to minutes in the time item in the main menu.
- Change Value The minus key on the keypad is used to change the value of the current item to the
previous value. This key scrolls through the values in the associated pick list
without displaying the full list.
+ Change Value The plus key on the keypad is used to change the value of the current menu item to
the next value. This key scrolls through the values in the associated pick list without
displaying the full list. On 106-key Japanese keyboards, the plus key has a different
scan code than the plus key on the other keyboard, but will have the same effect.
Setup Defaults Pressing the key causes the following to appear:
Load Optimized defaults? (Y/N)
If the key is pressed, all Setup fields are set to their default values. If the
key is pressed, or if the key is pressed, the user is returned to where they
were before the key was pressed without affecting any existing field values
Save and Exit Pressing the key causes the following message to appear:
Save Configuration and Reset? (Y/N)
If the key is pressed, all changes are saved and Setup is exited. If the key
is pressed, or the key is pressed, the user is returned to where they were
before the key was pressed without affecting any existing values.
Revision 1.3 59
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3.7.1.4 Menu Selection Bar
The menu selection bar is located at the top of the screen. It displays the major menu
selections.
3.7.2 Server Platform Setup Screens
The sections below describe the screens available for the configuration of a server platform. In
these sections, tables and figures are used to describe the contents of each screen. These
tables and figures follow the following guidelines:
The text and values in the Setup Item, Options, and Help columns are displayed on the
BIOS Setup screens.
Text in bold text in the Options columns indicates default values. These values are not
displayed in bold on the setup screen.
Text in the Options columns indicates options available.
The Comments column provides additional information where it may be helpful. This
information does not appear in the BIOS Setup screens.
Information in the screen shot figures that is enclosed in brackets (< >) indicates text
that varies, depending on the option(s) installed. For example is
replaced by the actual current date.
Information that is enclosed in ellipses brackets ({ }) in the tables indicates areas where
the user needs to type in text instead of selecting from a provided option.
60 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Figure 6. Setup Utility — Main Screen Display
Revision 1.3 61
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 15. Setup Utility — Main Screen Fields
Setup Item Options Help Text Comments
Logged in as
Information only. Displays
password level that setup is
running in, Administrator or User.
With no passwords set
Administrator is the default mode.
Platform ID Information only. Displays the
Platform ID. (example: SC5400RA,
S5000VSA, or S5000PAL)
System BIOS
Version Information only. Displays the
current BIOS version.
xx = major version
yy = minor version
zzzz = build number
Build Date Information only. Displays the
current BIOS build date.
Processor
processor name and the speed of
the CPU. This information is
retrieved from the processor.
Core Frequency Information only. Displays the
current speed of the boot processor
in GHz or MHz.
Count Information only. Number of
physical processors detected.
Memory
Size
Information only. Displays the
total physical memory installed in
the system, in MB or GB. The term
physical memory indicates the total
memory discovered in the form of
installed FBDIMMs.
Quiet Boot Enabled [Enabled] – Display the logo screen
during POST.
Disabled
[Disabled] – Display the diagnostic
screen during POST.
POST Error Pause Enabled [Enabled] – Go to the Error The POST error pause will take the
Manager for critical POST errors. system to the error manager to
Disabled
review the errors when Major errors
[Disabled] – Attempt to boot and do
occur. Minor and Fatal error
not go to the Error Manager for
displays are not affected by this
critical POST errors.
setting.
System Date [Day of week System Date has configurable
MM/DD/YYYY] fields for Month, Day, and Year.
Use [Enter] or [Tab] key to select
the next field.
Use [+] or [-] key to modify the
selected field.
62 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Setup Item Options Help Text Comments
System Time [HH:MM:SS] System Time has configurable
fields for Hours, Minutes, and
Seconds.
Hours are in 24-hour format.
Use [Enter] or [Tab] key to select
the next field.
Use [+] or [-] key to modify the
selected field.
Setup Item Options Help Text Comment
BIOS Version No entry allowed Information only. Displays the BIOS
version.
yy = major version
xx = minor version
zzzz = build number
BIOS Build Date No entry allowed Information only. Displays the BIOS
build date.
System ID No entry allowed Information only. Displays the
System ID. (example: S5000XVN,
S5000VSA, or S5000PAL)
Processor
Type No entry allowed Information only. Displays the Intel
processor name and speed.
Core Frequency No entry allowed Information only. Displays the
current speed of the boot processor
in GHz or MHz
Count No entry allowed Information only. The number of
processors detected.
Total Memory No entry allowed Information only. Displays the total
physical memory installed in the
system, in MB or GB. The term
phyiscal memory indicates the total
memory discovered in the form of
installed FBDIMMs.
Display Logo Enable If enabled, BIOS splash screen is
displayed. If disabled, BIOS POST
Disable
messages are displayed.
POST Error Pause Enable If enabled, the system will wait for The POST pause will take the
user intervention on critical POST system to the error manager to
Disable
errors. If disabled, the system will review the errors.
boot with no intervention, if
possible.
System Date [MM/DD/YYYY] Month valid values are 1 to 12. Help text depends on the subfield
selected (Month, Day, or Year).
Day valid values are 1 to 31.
Year valid values are 1998 to 2099.
System Time [HH:MM:SS] Hours valid values are 0 to 23. Help text depends on the subfield
selected (Hours, Minutes,
Minutes valid values are 0 to 59.
Seconds).
Seconds valid values are 0 to 59.
Revision 1.3 63
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3.7.2.1 Advanced Screen
The Advanced screen provides an access point to choose to configure several options. On this
screen, the user selects the option that is to be configured. Configurations are performed on the
selected screen, not directly on the Advanced screen.
To access the Advanced screen from the Main screen, press the right arrow until the Advanced
screen is chosen.
Figure 7. Setup Utility — Advanced Screen Display
64 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.7.2.1.1 Processor Screen
The Processor screen provides a place for the user to view the processor core frequency,
system bus frequency, and enable or disable several processor options. The user can also
select an option to view information about a specific processor.
To access this screen from the Main screen select Advanced | Processor.
Figure 8. Setup Utility — Processor Configuration Screen Display
Table 16. Setup Utility — Processor Configuration Screen Fields
Setup Item Options Help Text Comments
Core Frequency Information only. Frequency
at which processors currently
run.
System Bus Frequency
Information only. Current
frequency of the processor
front side bus.
Revision 1.3 65
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Setup Item Options Help Text Comments
Hyper-Threading Enabled Hyper-Threading Technology allows multi- This option is automatically
Technology threaded software applications to execute disabled when Dual Core is
Disabled
threads in parallel within each processor. disabled.
Contact your OS vendor regarding OS
support of this feature.
Enhanced Intel® Enhanced Intel SpeedStep® Technology
Enabled
SpeedStep Technology allows the system to dynamically adjust
Disabled
processor voltage and core frequency, which
can result in decreased average power
consumption and decreased average heat
production.
Contact your OS vendor regarding OS
support of this feature.
Core Multi-processing Enabled Core Multi-processing sets the state of
logical processor cores in a
Disabled
package. [Disabled] sets only logical
processor core 0 as enabled in each
processor package.
Note: If disabled, Hyper-Threading
Technology will also be automatically
disabled."
Intel® Virtualization Enabled Intel® Virtualization Technology allows a
Technology platform to run multiple operating systems
Disabled
and applications in independent partitions.
Note: A change to this option requires the
system to be powered off and then back on
before the setting will take effect.
Simulated MSI Support Enabled Enable or Disable simulation of Message
Signaled Interrupt (MSI) support.
Disabled
This feature can be Enabled in the case
where there is no OS support for Message
Signaled Interrupts.
Execute Disable Bit Enabled Execute Disable Bit can help prevent certain
classes of malicious buffer overflow attacks.
Disabled
Contact your OS vendor regarding OS
support of this feature.
Hardware Prefetcher Hardware Prefetcher is a speculative
Enabled
prefetch unit within the processor(s).
Disabled
Note: Modifying this setting may affect
system performance.
Adjacent Cache Line Enabled [Enabled] - Cache lines are fetched in pairs
Prefetch (even line + odd line).
Disabled
[Disabled] - Only the current cache line
required is fetched.
Note: Modifying this setting may affect
system performance.
Processor Retest Enabled Activate and retest all processors during
next boot only.
Disabled
Note: This option will automatically reset to
[Disabled] on the next boot, after all
processors are retested.
66 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Setup Item Options Help Text Comments
Processor 1 Information View Processor 1 information Select to view information
about processor 1. This takes
the user to a different screen.
Processor 2 Information View Processor 2 information Select to view information
about processor 2. This takes
the user to a different screen.
3.7.2.1.1.1 Processor # Information Screen
The Processor # Information screen provides a place to view information about a specific
processor.
To access this screen from the Main screen, select Advanced | Processor | Processor #
Information, where # is the processor number you want to see.
Figure 9. Setup Utility — Specific Processor Information Screen Display
Revision 1.3 67
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 17. Setup Utility — Specific Processor Information Screen Fields
Setup Item Options Help Text Comments
Processor <#>
Information only. Identifies family or generation of the processor.
Family
Maximum Information only. Maximum frequency the processor core supports.
Frequency
L2 Cache RAM Information only. Size of the processor L2 cache.
Processor Stepping Information only. Stepping number of the processor.
CPUID Register Information only. CPUID register value identifies details about the processor
family, model, and stepping.
3.7.2.1.2 Memory Screen
The Memory screen provides a place for the user to view details about the system memory
FBDIMMs that are installed. On this screen, the user can select an option to open the Configure
Memory RAS and Performance screen.
To access this screen from the Main screen, select Advanced | Memory.
68 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Figure 10. Setup Utility — Memory Configuration Screen Display
Table 18. Setup Utility — Memory Configuration Screen Fields
Setup Item Options Help Text Comments
Total Memory Information only. The amount of memory
available in the system in the form of
installed FBDIMMs, in units of MB or GB.
Effective Memory Information only. The amount of memory
available to the operating system in MB or
GB.
The Effective Memory is the difference
between Total Physical Memory and the
sum of all memory reserved for internal
usage, RAS redundancy and SMRAM.
This difference includes the sum of all
FBDIMMs that failed Memory BIST during
POST, or were disabled by the BIOS
during memory discovery phase in order to
optimize memory configuration.
Revision 1.3 69
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Setup Item Options Help Text Comments
Current Configuration Information only. Displays one of the
following:
Maximum Performance Mode: System
memory is configured for optimal
performance and efficiency and no RAS
is enabled.
• Single-Channel Mode: System
memory is functioning in a special,
reduced efficiency mode. Memory
Mirroring Mode: System memory is
configured for maximum reliability in the
form of memory mirroring.
Current Memory Information only. Displays speed at which
Speed
the memory is running.
Memory RAS and Configure memory RAS Select to configure the memory RAS and
Performance (Reliability, Availability, performance. This takes the user to a
Configuration and Serviceability) and different screen.
view current memory
performance information
and settings.
DIMM_# Displays the state of each DIMM socket
present on the board. Each DIMM socket
field reflects one of the following possible
states:
Installed: There is a FBDIMM
installed in this slot.
Not Installed: There is no FBDIMM
installed in this slot.
Disabled: The FBDIMM installed in
this slot has been disabled by the BIOS
in order to optimize memory
configuration.
Failed: The FBDIMM installed in this
slot is faulty / malfunctioning.
Spare Unit: The FBDIMM is
functioning as a spare unit for memory
RAS purposes.
70 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.7.2.1.2.1 Memory RAS and Performance Screen
Figure 11. Setup Utility — Memory RAS and Performance Configuration Screen Display
Table 19. Setup Utility — Memory RAS and Performance Configuration Screen Fields
Setup Item Options Help Text Comments
Memory Mirroring Yes / No Information only. Only displayed
Possible on systems with chipsets that are
capable of Memory Mirroring.
Memory Sparing Yes / No Information only
Possible
Revision 1.3 71
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Setup Item Options Help Text Comments
Select Memory RAS RAS Disabled/ Available modes depend on the Provides options for configuring
Configuration Mirroring / Sparing current memory population. Memory RAS.
The BIOS will dynamically
configure this menu to display only
[RAS Disabled] - Optimizes
those RAS modes that can be
system performance.
supported with the current layout
and positioning of the FBDIMMs
[Mirroring] - Optimizes reliability
on the board. If no RAS mode is
by using half of physical
possible for the current FBDIMM
memory as a backup.
configuration/layout, this setup
item will not provided.
RAS Disabled: The default in
[Sparing] - Improves reliability
by reserving memory for use as normal mode of operation. In
a replacement in the event of this mode, no Memory RAS is
DIMM failure.
supported.
Mirroring: Available and
displayed only when the
FBDIMM population is capable
of supporting memory mirroring.
When this option is available
and selected, the BIOS will
reconfigure memory in the
mirroring mode on the next
boot.
Sparing: Available and
displayed only when the
FBDIMM population can
support memory sparing.
Snoop Filter Enabled The Snoop Filter component Only available on systems using
monitors and controls the data the 5000X system boards, i.e.,
Disabled
transactions between memory SC5400RA, S5000XAL, or
and the processor(s). S5000XVN.
FSB High Bandwidth Enabled [Enabled] – Optimize Front Side Configure based on performance
Optimization Bus for higher bandwidth when results.
Disabled
1333 MHz FSB processor(s)
Must have processor(s) installed
installed.
with1333 MHz Front Side Bus
Note: Some applications will frequency.
benefit from this option
[Enabled]. Configure based on
performance results.
3.7.2.1.3 ATA Controller Screen
The ATA Controller screen provides fields to configure PATA and SATA hard disk drives. It also
provides information on the hard disk drives that are installed.
To access this screen from the Main screen, select Advanced | ATA Controller.
72 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Figure 12. Setup Utility — ATA Controller Configuration Screen Display
Revision 1.3 73
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 20. Setup Utility — ATA Controller Configuration Screen Fields
Setup Item Options Help Text Comments
Onboard PATA Onboard Parallel ATA (PATA)
Enabled
Controller controller.
Disabled
Onboard SATA Onboard Serial ATA (SATA) When enabled, the SATA
Enabled
Controller controller. controller can be configured in
Disabled
IDE, RAID, or AHCI Mode. RAID
and AHCI modes are mutually
exclusive.
SATA Mode Enhanced [Enhanced] - Configures all In Legacy Mode, BIOS can
SATA ports as individual ports. enumerate only four drives. It
Legacy
This is also known as native provides four options to choose a
mode. mix of SATA and PATA drives
(see Legacy IDE Channel option
below).
[Legacy] - Configures SATA
In Enhanced Mode, the BIOS is
ports to be primary and/or
not limited to legacy PATA four-
secondary channels. This is also
drive limitations, and can
known as compatibility mode.
enumerate the two PATA drives
and four SATA drives (totaling six
drives) regardless of AHCI mode,
and can list/boot to the remaining
two SATA drives as well with
AHCI Support.
AHCI and RAID Modes are
supported only when SATA Mode
is selected as “Enhanced”.
Legacy IDE Channel SATA Only [SATA Only] - Master/slave for Displayed only when Legacy is
primary are SATA port 0/2. For chosen for the SATA Mode.
Secondary SATA
secondary they are port 1/3.
Primary SATA
[Secondary SATA] - Master/slave
PATA Only
for primary are PATA. For
secondary they are SATA port
1/3.
[Primary SATA] - Master/slave
for primary are SATA port 0/2.
For secondary they are PATA.
[PATA Only] - Master/slave for
primary are PATA. SATA ports
are disabled.
74 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Setup Item Options Help Text Comments
AHCI Mode Enabled Advanced Host Controller Unavailable if the SATA mode is
Interface (AHCI) option ROM will “Legacy” or if RAID Mode is
Disabled
enumerate all AHCI devices selected.
connected to the SATA ports.
When AHCI is enabled:
Contact your OS vendor
The identification and
regarding OS support of this
configuration is left to the AHCI
feature.
Option ROM. Only devices
supported by the AHCI Option
ROM will be displayed in setup
(SATA HDD and SATA CDROM)
other devices are available in the
OS after their drivers are loaded.
SATA 4 and SATA 5 will appear
in the HDD information listing.
Configure SATA as Enabled SATA controller will be in RAID Unavailable when AHCI mode is
RAID mode and the Intel® RAID for enabled. This mode can be
Disabled
Serial ATA option ROM will selected only when the SATA
execute. controller is in Enhanced Mode.
When this mode is enabled, no
SATA drive information is
displayed.
Primary IDE Master
Primary IDE Slave < Not Installed / Drive Information only
information>
SATA Port 0 < Not Installed / Drive
Information only; Unavailable
information> when RAID Mode is enabled.
SATA Port 1 < Not Installed / Drive
Information only; This field is
information> unavailable when RAID Mode is
enabled.
SATA Port 2 < Not Installed / Drive Information only; This field is
information> unavailable when RAID Mode is
enabled.
SATA Port 3 < Not Installed / Drive Information only; This field is
information>
unavailable when RAID Mode is
enabled.
SATA Port 4 < Not Installed / Drive Information only; This field is
information> only available when AHCI Mode
is enabled.
SATA Port 5 < Not Installed / Drive
Information only; This field is
information> only available when AHCI Mode
is enabled.
Revision 1.3 75
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3.7.2.1.4 Mass Storage Screen
The Mass Storage screen provides fields to configure when a SAS controller is present on the
®
baseboard, mid-plane or backplane of an Intel system.
To access this screen from the Main menu, select Advanced | Mass Storage.
Figure 13. Setup Utility — Mass Storage Configuration Screen Display
Table 21. Setup Utility — Mass Storage Configuration Screen Fields
Setup Item Options Help Text Comments
SAS Controller Enabled Enable or Disable the onboard
Serial Attached SCSI (SAS)
Disabled
Controller.
Configure SAS as SW Enabled SAS ports will be configured for Unavailable if device is disabled or if
RAID Intel® Embedded Server RAID Intel® RAID Activation Key
Disabled
Technology. AXXRAK18E is present.
76 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Setup Item Options Help Text Comments
Intel® RAID Activation Key Present Information only; Unavailable when
AXXRAK18E Intel® RAID Controller
Not Present
SROMBSAS18E is not present
3.7.2.1.5 Serial Ports Screen
The Serial Ports screen provides fields to configure the Serial A [COM 1] and Serial B [COM2].
To access this screen from the Main screen, select Advanced | Serial Port.
Figure 14. Setup Utility — Serial Port Configuration Screen Display
Revision 1.3 77
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 22. Setup Utility — Serial Ports Configuration Screen Fields
Setup Item Options Help Text Comments
Serial A Enabled Enable or Disable Serial port A.
Enable
Disabled
Address Select Serial port A base I/O address.
3F8h
2F8h
3E8h
2E8h
IRQ 3 Select Serial port A base interrupt request (IRQ)
line.
4
Enabled
Serial B Enable or Disable Serial port B.
Enable
Disabled
Address 3F8h Select Serial port B base I/O address.
2F8h
3E8h
2E8h
IRQ 3 Select Serial port B base interrupt request (IRQ)
line.
4
3.7.2.1.6 USB Configuration Screen
The USB Configuration screen provides fields to configure the USB controller options.
To access this screen from the Main screen, select Advanced | USB Configuration.
78 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Figure 15. Setup Utility — USB Controller Configuration Screen Display
Table 23. Setup Utility — USB Controller Configuration Screen Fields
Setup Item Options Help Text Comments
Detected USB
Information only: shows number of
Devices USB devices in system
USB Controller [Enabled] - All onboard USB controllers will be turned on
Enabled
and accessible by the OS.
Disabled
[Disabled] - All onboard USB controllers will be turned off
and inaccessible by the OS.
Legacy USB Enabled PS/2 emulation for USB keyboard and USB mouse
Support devices.
Disabled
Auto
[Auto] - Legacy USB support will be enabled if a USB
device is attached.
Port 60/64 Enabled I/O port 60h/64h emulation support.
Emulation
Disabled
Note: This may be needed for legacy USB keyboard
support when using an OS that is USB unaware.
Revision 1.3 79
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Setup Item Options Help Text Comments
Device Reset 10 sec USB Mass storage device Start Unit command timeout.
timeout
20 sec
30 sec
40 sec
Header for next line.
Storage Emulation
One line for each Auto [Auto] - USB devices less than 530MB will be emulated as This setup screen can show a
mass storage floppy. maximum of 8 devices on this
Floppy
device in system screen. If more than 8 devices are
Forced FDD
installed in the system, the ‘USB
[Forced FDD] - HDD formatted drive will be emulated as
Hard Disk
Devices Enabled’ will show the
FDD (e.g., ZIP drive).
correct count, but only the first 8
CD-ROM
devices can be displayed here.
USB 2.0 Enabled Onboard USB ports will be enabled to support USB 2.0
controller mode. USB devices will operate in USB 1.1 mode during
Disabled
POST.
Contact your OS vendor regarding OS support of this
feature.
80 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.7.2.1.7 PCI Screen
The PCI Screen provides fields to configure PCI add-in cards, the onboard NIC controllers, and
video options.
To access this screen from the Main screen, select Advanced | PCI.
Figure 16. Setup Utility — PCI Configuration Screen Display
Revision 1.3 81
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 24. Setup Utility — PCI Configuration Screen Fields
Setup Item Options Help Text Comments
Memory Mapped I/O 1.5GB Select the start of the reserved memory region for For all PAE (Physical
Start Address PCI memory mapped I/O space that ends at 4GB. Address Extension) aware
1.75GB
Operating Systems, 2.5GB
2.00GB
should be selected. The
Warning: Depending on the system configuration,
2.25GB
system will remap memory
this option may impact the amount of system
and the OS will detect all
2.5GB
memory detected by an OS without Physical
memory installed in the
2.75GB
Address Extension (PAE) support.
system. If the installed OS
3.00GB
does not support PAE, the
maximum memory size
3.25GB
detected is linked to the
3.50GB
setup option
selected. For example,
if 2.5GB is selected, only
2.5GB will be detected by
the OS.
Memory Mapped I/O Enabled Enable or disable memory mapped I/O of 64-bit
above 4GB PCI devices to 4GB or greater address space.
Disabled
Onboard Video Enabled Onboard video controller. When disabled, the system
requires an add-in video
Disabled
card in order for video to
Warning: System video will be completely
be seen.
disabled if this option is disabled and an add-in
video adapter is not installed.
Dual Monitor Video Enabled Both the onboard video controller and an add-in
video adapter will be enabled for system video.
Disabled
The onboard video controller will be the primary
video device.
Onboard NIC ROM Load the embedded option ROM for the onboard
Enabled
network controllers.
Disabled
Warning: If [Disabled] is selected, NIC1 and NIC2
can not be used to boot or wake the system.
I/O Module NIC ROM Enabled Load the embedded option ROM for the onboard Option only displays when
network controller on the I/O module. a Dual GigE I/O Module is
Disabled
Installed
NIC 1 MAC Address No entry Information only. 12 hex
allowed
digits of the MAC address.
NIC 2 MAC Address No entry Information only. 12 hex
allowed
digits of the MAC address.
Intel® I/OAT Enabled Intel® I/O Acceleration Technology (I/OAT)
accelerates TCP/IP processing for onboard NICs,
Disabled
delivers data-movement efficiencies across the
entire server platform, and minimizes system
overhead.
3.7.2.1.8 System Acoustic and Performance Configuration
The System Acoustic and Performance Configuration screen provides fields to configure the
thermal characteristics of the system.
82 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
To access this screen from the Main screen, select Advanced | System Acoustic and
Performance Configuration.
Figure 17. Setup Utility — System Acoustic and Performance Configuration Screen Display
Revision 1.3 83
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 25. Setup Utility — System Acoustic and Performance Configuration Screen Fields
Setup Item Options Help Text Comments
Throttling Mode Open Loop sets up a static level which equates to a
Open Loop
fixed bandwidth. It does not rely on a thermal sensor on
Closed Loop
the board.
Closed Loop will allow the system to achieve higher
performance by monitoring system temps and adjusting
bandwidth.
Set Fan Profile Performance Select the fan control profile that will be used to cool Performance
the system. mode favors
Acoustic
using fans over
throttling
memory
bandwidth to
cool the system.
Note: This
option is only
available when
Open Loop
Throttling Mode
is selected.
Altitude 300 M or less 300 M or less (<= 980ft): Provides the best Note: This
performance option for servers operating at or near sea option is
301 M - 900 M
level.
unavailable
Higher than 900 M
when the BIOS
301 M – 900 M (980ft - 2950ft): Provides the best
supports Closed
performance option for servers operating at moderate
Loop Throttling
altitudes above sea level.
Mode.
Higher than 900 M (>2950ft): Provides the best
performance option for servers operating at high
elevations above sea level.
3.7.2.2 Security Screen
The Security screen provides fields to enable and set the user and administrative password and
to lockout the front panel buttons so they cannot be used.
To access this screen from the Main screen, select the Security option.
84 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Figure 18. Setup Utility — Security Configuration Screen Display
Revision 1.3 85
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 26. Setup Utility — Security Configuration Screen Fields
Setup Item Options Help Text Comments
Administrator Password
password.
User Password Status
Set Administrator [123abcd] Administrator password is used to This option is only to control
Password control change access in BIOS Setup access to setup.
Utility. Administrator has full
access to all setup items.
Only alphanumeric characters can be
Clearing the Admin
used. Maximum length is 7 characters.
password will also clear the
Note: The password is case sensitive.
user password.
Note: Administrator password must be
set in order to use the user account.
Set User Password [123abcd] User password is used to control entry Available only if
access to BIOS Setup Utility. Administrator Password is
installed. This option only
Only alphanumeric characters can be
protects setup. User
used. Maximum length is 7 characters.
password only has limited
Note: The password is case sensitive.
access to setup items.
Note: Removing the administrator
password will also automatically remove
the user password.
Front Panel Lockout Enabled Locks the power button and reset button
on the system's front panel. If [Enabled]
Disabled
is selected, power and reset must be
controlled via a system management
interface.
86 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.7.2.3 Server Management Screen
The Server Management screen provides fields to configure several server management
features. It also provides an access point to the screens for configuring console redirection and
displaying system information.
To access this screen from the Main screen, select the Server Management option.
Figure 19. Setup Utility — Server Management Configuration Screen Display
Table 27. Setup Utility — Server Management Configuration Screen Fields
Setup Item Options Help Text Comments
Assert NMI on SERR On SERR, generate an NMI and log an error.
Enabled
Disabled Note: [Enabled] must be selected for the Assert NMI
on PERR setup option to be visible.
Assert NMI on PERR On PERR, generate an NMI and log an error.
Enabled
Disabled Note: This option is only active if the Assert NMI on
SERR option is [Enabled] selected."
Revision 1.3 87
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Setup Item Options Help Text Comments
Resume on AC Power Stay Off System action to take on AC power loss recovery.
Loss
Last state [Stay Off] - System stays off.
Reset [Last State] - System returns to the same state before
the AC power loss.
[Reset] - System powers on.
Clear System Event Enabled Clears the System Event Log. All current entries will
Log be lost.
Disabled
Note: This option will be reset to [Disabled] after a
reboot.
FRB-2 Enable Enabled Fault Resilient Boot (FRB).
Disabled BIOS programs the BMC watchdog timer for
approximately 6 minutes. If BIOS does not complete
POST before the timer expires, the BMC will reset the
system.
O/S Boot Watchdog Enabled BIOS programs the watchdog timer with the timeout
Timer value selected. If the OS does not complete booting
Disabled
before the timer expires, the BMC will reset the
system and an error will be logged.
Requires OS support or Intel Management Software.
O/S Boot Watchdog Power Off If the OS watchdog timer is enabled, this is the system
Timer Policy action taken if the watchdog timer expires.
Reset
[Reset] - System performs a reset.
[Power Off] - System powers off.
O/S Boot Watchdog 5 minutes If the OS watchdog timer is enabled, this is the
Timer Timeout timeout value BIOS will use to configure the watchdog
10 minutes
timer.
15 minutes
20 minutes
Console Redirection View/Configure console redirection information and Takes user to Console
settings. Redirection Screen.
System Information View system information Takes user to System
Information Screen.
3.7.2.3.1 Console Redirection Screen
The Console Redirection screen provides a way to enable or disable console redirection and to
configure the connection options for this feature.
To access this screen from the Main screen, select Server Management. Select the Console
Redirection option from the Server Management screen.
88 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Figure 20. Setup Utility — Console Redirection Screen Display
Table 28. Setup Utility — Console Redirection Configuration Fields
Setup Item Options Help Text Comments
Console Redirection Console redirection allows a serial port to be used for
Disabled
server management tasks.
Serial A
[Disabled] - No console redirection.
Serial B
[Serial Port A] - Configure serial port A for console
redirection.
[Serial Port B] - Configure serial port B for console
redirection.
Enabling this option will disable display of the Quiet
Boot logo screen during POST.
Flow Control None Flow control is the handshake protocol.
RTS/CTS Setting must match the remote terminal application.
[None] - Configure for no flow control.
[RTS/CTS] - Configure for hardware flow control.
Revision 1.3 89
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Setup Item Options Help Text Comments
Baud Rate 9600 Serial port transmission speed. Setting must match
the remote terminal application.
19.2K
38.4K
57.6K
115.2K
Terminal Type PC-ANSI Character formatting used for console redirection.
Setting must match the remote terminal application.
VT100
VT100+
VT-UTF8
Legacy OS Disabled This option will enable legacy OS redirection (i.e.,
Redirection DOS) on serial port. If it is enabled the associated
Enabled
serial port will be hidden from the legacy OS.
3.7.2.4 Server Management System Information Screen
The Server Management System Information screen provides a place to see part numbers,
serial numbers, and firmware revisions.
To access this screen from the Main screen, select Server Management. Select the System
Information option from the Server Management screen.
Figure 21. Setup Utility — Server Management System Information Screen Display
90 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Table 29. Setup Utility — Server Management System Information Fields
Setup Item Options Help Text Comments
Board Part Number
Information Only
Board Serial Number Information Only
System Part Number Information Only
System Serial Number Information Only
Chassis Part Number Information Only
Chassis Serial Number Information Only
BMC Firmware Revision Information Only
HSC Firmware Revision Information Only
SDR Revision Information Only
UUID Information Only
3.7.2.5 Boot Options Screen
The Boot Options screen displays any bootable media encountered during POST, and allows
the user to configure desired boot device.
To access this screen from the Main screen, select Boot Options.
Revision 1.3 91
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Figure 22. Setup Utility — Setup Utility – Boot Options Screen Display
92 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Table 30. Setup Utility — Setup Utility – Boot Options Screen Display
Setup Item Options Help Text Comments
Boot Timeout 0 - 65535 The number of seconds BIOS will After entering the desired
pause at the end of POST to allow the timeout, press enter to
user to press the [F2] key for entering register that timeout value to
the BIOS Setup Utility. the system. These settings
are in seconds.
Valid values are 0-65535. Zero is the
default. A value of 65535 will cause the
system to go to the Boot Manager
menu and wait for user input for every
system boot.
Boot Option #x Available boot Set system boot order by selecting the
devices. boot option for this position.
Hard Disk Order Set hard disk boot order by selecting Appears when more than 1
the boot option for this position. hard disk drive is in the
system.
CDROM Order Set CDROM boot order by selecting Appears when more than 1
the boot option for this position. CDROM drive is in the
system.
Floppy Order Set floppy disk boot order by selecting Appears when more than 1
the boot option for this position. floppy drive is in the system.
Network Device Order Set network device boot order by Appears when more than 1
selecting the boot option for this of these devices is available
position. Add-in or onboard network in the system.
devices with a PXE option ROM are
two examples of network boot devices.
BEV Device Order Set the Bootstrap Entry Vector (BEV) Appears when more than 1
device boot order by selecting the boot of these devices is available
option for this position. in the system.
BEV devices require their own
proprietary method to load an OS using
a bootable option ROM. BEV devices
are typically found on remote program
load devices.
Boot Option Retry Enabled/Disabled This will continually retry NON-EFI
based boot options without waiting for
user input.
3.7.2.6 Boot Manager Screen
The Boot Manager screen displays a list of devices available to boot from, and allows the user
to select a boot device for this boot.
To access this screen from the Main screen, select Boot Options.
Revision 1.3 93
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Figure 23. Setup Utility — Setup Utility – Boot Manager Screen Display
Table 31. Setup Utility — Setup Utility – Boot Manager Screen Display
Setup Item Options Help Text Comments
Launch EFI Shell Select this option to boot now.
Note: This list is not the system boot
option order. Use the Boot Options
menu to view and configure the system
boot option order.
Boot Device #x Select this option to boot now.
Note: This list is not the system boot
option order. Use the Boot Options
menu to view and configure the system
boot option order.
94 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.7.2.7 Error Manager Screen
The Error Manager screen displays any errors encountered during POST.
Figure 24. Setup Utility — Error Manager Screen Display
Table 32. Setup Utility — Error Manager Screen Fields
Setup Item Option Help Text Comments
s
Displays System Errors Information only. Displays errors that
occurred during this POST.
3.7.2.8 Exit Screen
The Exit screen allows the user to choose to save or discard the configuration changes made
on the other screens. It also provides a method to restore the server to the factory defaults or to
save or restore a set of user defined default values. If Restore Defaults is selected, the default
settings, noted in bold in the tables in this chapter, will be applied. If Restore User Default
Values is selected, the system is restored to the default values that the user saved earlier,
instead of being restored to the factory defaults.
Revision 1.3 95
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Figure 25. Setup Utility — Exit Screen Display
Table 33. Setup Utility — Exit Screen Fields
Setup Item Help Text Comments
Save Changes and Exit Exit BIOS Setup Utility after saving changes. User is prompted for confirmation only
The system will reboot if required. if any of the setup fields were
modified.
The [F10] key can also be used.
Discard Changes and Exit BIOS Setup Utility without saving changes. User is prompted for confirmation only
Exit if any of the setup fields were
The [Esc] key can also be used.
modified.
Save Changes Save changes without exiting BIOS Setup User is prompted for confirmation only
Utility. if any of the setup fields were
modified.
Note: Saved changes may require a system
reboot before taking effect.
Discard Changes Discard changes made since the last save User is prompted for confirmation only
changes operation was performed. if any of the setup fields were
modified.
Load Default Values Load factory default values for all BIOS Setup User is prompted for confirmation.
Utility options.
The [F9] key can also be used.
96 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Setup Item Help Text Comments
Save as User Default Save current BIOS Setup Utility values as User is prompted for confirmation.
Values custom user default values. If needed, the user
default values can be restored via the Load
User Default Values option below.
Note: Clearing CMOS or NVRAM will cause the
user default values to be reset to the factory
default values.
Load User Default Load user default values. User is prompted for confirmation.
Values
3.8 Loading BIOS Defaults
Different mechanisms exist for resetting the system configuration to the default values. When a
request to reset the system configuration is detected, the BIOS loads the default system
configuration values during the next POST. The request to reset the system to the defaults can
be sent in the following ways:
A request to reset the system configuration can be generated by pressing from
within the BIOS Setup utility.
A reset system configuration request can be generated by moving the clear CMOS
configuration jumper.
The following steps will load the BIOS defaults:
1. Power down the system. (Do not remove AC power.)
2. Move the Clear CMOS jumper from pins 1-2 to pins 2-3.
3. Move the Clear CMOS jumper from pins 2-3 to pins 1-2.
4. Power up the system.
3.9 Security
The BIOS provides several security features. This section describes the security features and
operating model.
3.9.1 Operating Model
The following table summarizes the operation of security features supported by the BIOS.
Revision 1.3 97
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 34. Security Features Operating Model
Mode Entry Method / Entry Criteria Behavior Exit Criteria After Exit
Event
Password on Power On / User password set System halts for User Front control panel
boot Reset and password on user password password. buttons are re-
boot enabled in before scanning enabled.
Administrator
BIOS Setup. option ROMs.
password. The server boots
Secure boot The system is
normally. Boot
disabled in BIOS not in secure
sequence is
Setup. mode.
determined by setup
No mouse or options.
keyboard input is
accepted except
the password.
3.9.2 Password Protection
The BIOS uses passwords to prevent unauthorized tampering with the server setup. Both user
and administrator passwords are supported by the BIOS. An Administrator password must be
entered in order to set the user password. The maximum length of the password is seven
characters. The password cannot have characters other than alphanumeric (a-z, A-Z, 0-9). The
Administrator and User passwords are case sensitive
Once set, a password can be cleared by changing it to a null string. Entering the user password
will allow the user to modify the time, date, and user password. Other setup fields can be
modified only if the administrator password is entered. If only one password is set, this
password is required to enter BIOS Setup.
The administrator has control over all fields in BIOS Setup, including the ability to clear the user
password.
If the user or administrator enters an incorrect password three times in a row during the boot
sequence, the system is placed into a halt state. A system reset is required to exit out of the halt
state. This feature makes it difficult to break the password by guessing at it.
3.9.3 Password Clear Jumper
If the user and/or administrator password is lost or forgotten, both passwords may be cleared by
moving the password clear jumper into the clear position and powering on the system. The
BIOS determines if the password clear jumper is in the clear position during BIOS POST and
clears any passwords if required. The password clear jumper must be restored to its original
position before new passwords can be set.
3.10 BIOS Update Flash Procedures
3.10.1 Intel Iflash32 BIOS Update Utility
The Intel Iflash32 BIOS Update Utility is designed to update the system BIOS in a DOS
environment.
98 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Boot to the ROM-DOS shell and copy IFlash32.exe and the BIOS binary file (also referred as
capsule file) to a DOS bootable diskette, CD or disk-on-key.
3.10.1.1 Command line Interface
IFlash32 [File Name] [Options]
To view the command-line help page: IFlash32 /h
To update the System BIOS: IFlash32 [File Name] /u
To display file information: IFlash32 [File Name] /i
To display the system BIOS ID: IFlash32 /i
To update the system BIOS in non-interactive mode: IFlash32 [FileName] /u /ni
To automatically reboot system after a system BIOS update: IFlash32 [FileName] /u /r
Reboot the system after the BIOS update is completed.
®
3.10.2 Intel One Boot Flash Update Utility
®
The Intel One Boot Flash Update utility is run by executing the flashupdt command from a
command prompt.
In order to run this utility, you must first set the working directory to the directory where the utility
is installed. This is required because the utility depends on certain files that are expected to be
located in the working directory.
®
The Intel One Boot Flash Update utility requires Windows* administrative or Linux root
permission.
3.10.2.1 Command Line Syntax
flashupdt [-i] [-u < URL or path >] [-c] [-h|?]
This command updates the System BIOS or firmware on the local server with the System BIOS
®
or firmware specified in the Intel One Boot Flash Update utility configuration file provided with
the update package.
[–i] Displays the version information for the currently running System BIOS, BMC, and SDR. If
the –i option is specified with the –u option, the utility displays the version information of the
update package files.
[–u] Performs the System BIOS and firmware update. The parameter specifies
the location where the files required for the update are located. The value of
can be a local file system path, an FTP server, or an HTTP server. Examples of using the –u
option:
–u Specifies the current local directory.
–u http:/// Specifies an HTTP server.
–u ftp://@ Specifies an FTP server.
/
If –u is used in conjunction with –i, no update is performed. Only the package information is
displayed.
[–c] Cancels all pending update operations of the BIOS, BMC and SDR that were performed
using the utility. The utility resets the internal flags in the BIOS, BMC and SDR to cancel the
update operation, whether there is one or not. FRU updates take effect immediately.
Revision 1.3 99
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
[–h|?] Displays command line help information.
Syntax examples:
flashupdt –u ftp://ftp.examplesite.com/UpdatePackage/ServerName
flashupdt –u "ftp://ftp.examplesite.com/Update Package/Server
Name"
flashupdt –u
ftp://Kevin:87w09@ftp.examplesite.com/UpdatePackage/ServerName
For Windows*:
flashupdt –u c:\UpdatePackage\ServerName
For Linux:
flashupdt –u /UpdatePackage/ServerName
3.10.2.2 Updating the Server from a Remote Client
This utility can be executed remotely via a secure network connection using a Telnet Client and
Terminal Services in Windows, or using a Telnet Client and Remote Shell under Linux. See your
operating system documentation for information about remotely logging in and executing
commands.
Once you have logged-in remotely, you can use the syntax described above. This process can
be scripted to allow remote updates of multiple servers.
®
3.10.2.3 Uninstalling Intel One Boot Flash Update
®
This section describes the procedures for uninstalling the Intel One Boot Flash Update Utility.
3.10.2.3.1 Microsoft Windows*
®
To remove Intel One Boot Flash Update utility from a Windows* operating system, do the
following:
®
1. Open a Command Prompt window and change the working directory to the Intel One
Boot Flash Update utility installation directory:
cd C:\\bin\flashupdt
2. To uninstall drivers execute the following command:
uninstall.cmd
3. Delete all remaining files in the directory.
4. Reboot the server.
100 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
3.10.2.3.2 Linux
®
To remove the Intel One Boot Flash Update utility from a Linux operating system, do the
following:
1. Log in as root.
2. Open a terminal and change the working directory to the Intel® One Boot Flash Update
utility installation directory:
cd /usr/local/flashupdt
3. Execute the following command:
/uninstall
3.11 BIOS Bank Select and One Boot Flash Update
One Boot Flash Update refers to the ability to update the BIOS while the server is online and
operating.
The BIOS Bank Select feature provides the ability to update the BIOS in a fault tolerant way. If
the updated (new) BIOS is found to be non functional for any reason, the system can still be
booted by rolling back to the previous, healthy BIOS.
® ®
All Intel server boards and systems that use the Intel 5000 Chipset Sequence have 4 MB of
flash space for system BIOS. This flash is divided into 2 banks of 2 MB each. One of the banks
is called upper bank and the other is called lower bank. The BIOS can reside in either or both of
these banks. The BIOS area from which the system boots at any point in time is called the
Primary BIOS Partition. The other BIOS area is called the Secondary BIOS Partition. All BIOS
updates are made only to the Secondary BIOS Partition.
Note: The primary and secondary BIOS partitions are logical partition on a 4 MB system flash.
They can reside on either of the two physical banks.
The BIOS relies on specialized hardware and additional flash space for a BIOS Bank Select and
One Boot Flash Update. The BIOS Bank Select Jumper is used to direct the behavior of the
BIOS once the online update is performed. The BIOS Bank Select Jumper has two modes.
1-2 Recovery Mode
2-3 Normal Operation (Default)
BIOS updates can be made with the BIOS Bank Select Jumper in either of the two positions.
The behavior of the system in either of these modes is described below.
3.11.1 BIOS Bank Select Jumper in Normal Mode (Jumper Pins 2 - 3
connected)
In normal mode, the new BIOS image is updated onto the secondary partition and is validated. If
the validation is successful, the BIOS uses specialized hardware to notify the system to boot
from the new BIOS, and resets the system. The new BIOS begins to boot. If the boot is
Revision 1.3 101
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
successful, the BIOS update is complete. If the new BIOS fails to boot successfully, a timer is
started and the system rolls back to the previous, healthy BIOS image.
1. Boot the system with the jumper covering pins 2 and 3.
®
2. Update the BIOS using iFlash32.exe or the Intel One Flash Update (Intel® One
Boot Flash Update utility) utility.
3. Reset the system.
4. The current BIOS will validate and then boot from the new BIOS.
5. If the new BIOS fails, roll back occurs and the system boots with the old BIOS.
3.11.2 BIOS Bank Select Jumper in Recovery Mode (Jumper pins 1 - 2
connected)
If the user wants or needs to update the primary BIOS image the BIOS Bank Select jumper may
be moved to force the BIOS to boot from the secondary partition of the flash.
1. Boot the system with the jumper covering pins 1 and 2.
®
2. Update the BIOS using iFlash or the Intel One Boot Flash Update utility.
3. Reset the system.
4. The system boots from the old BIOS.
5. If the new BIOS needs to be used, power off the system and move the jumper to
cover pins 2 and 3, then power on the system.
6. If the new BIOS is healthy, the system boots with the new BIOS.
7. If the BIOS is corrupted or incompatible, the system does not roll back to the healthy
BIOS. The user should power down the system, move the jumper to cover pins 1 and
2, power up the server to boot to the older BIOS.
3.12 OEM Binary
A firmware volume is reserved for OEMs. The OEM firmware volume is used to contain the
OEM logo and is updated independently of other firmware volumes. The OEM firmware volume
hosts a firmware file system. The size of the OEM firmware volume is 192 KB.
3.12.1 Splash Logo
The OEM FV can include the OEM splash logo and may be updated using the Change Logo
utility. If an OEM logo is located in the firmware volume, it is used in place of the standard Intel
logo. The logo file can be identified based on the file name.
The logo file must follow the standard framework format for graphical images. The size must not
exceed 800 x 512 pixels. The number of colors cannot exceed 256, although the actual number
of colors may be much fewer due to image size constraints.
3.13 Boot Device Selection
The Boot Device Selection phase is responsible for controlling the booting of the system. The
boot option variables are set by an operating system during operating system installation or
102 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
manually added by the user through the Boot Maintenance Manager of the Setup utility. The
Boot Maintenance Manager provides the capability to make permanent changes to the boot
order. It is also possible to change the first boot option for a single boot.
3.13.1 USB Boot Device Reordering
In order to facilitate priority boot of various external USB boot devices & media without the need
to enter the Setup Utility and reconfigure the saved Boot Options, BIOS will automatically adjust
Boot Options for bootable USB devices. This automatic reordering of USB boot devices only
occurs when a USB device is newly detected and not found in the previous configured boot
order. When that USB boot device is removed, the configured order of Boot Options is restored.
If a standard boot device of the same type (Hard Disk, CDROM, Floppy) is already present in
the configured Boot Options, then the USB boot device of that type is given priority and moved
to the top of that device type boot order to boot before other devices of the same
type. However, the position of that device type in the Boot Manager order is not changed to
preserve the configured boot device type order. If a standard boot device of the same type is
not already present in the configured Boot Options, then that type is given priority and moved to
the top position in the Boot Manager order to boot before other device types already configured.
If the USB boot device is not intended for a one-time boot and will remain in the system
configuration more permanently, then the boot order including the USB device can still be
configured and saved in the Setup Utility and will be preserved as a permanent change to the
boot order.
For security reasons, this USB boot device reordering will not occur if the User Password has
been installed via the Security Configuration Screen in the Setup Utility.
3.13.2 Server Managment Boot Device Control
The IPMI 2.0 specification includes provisions for server management devices to set certain
boot parameters by setting boot flags.
The BIOS supports booting from the following:
PXE
HDD (USB, SATA, SAS, and PATA)
USB FDD
USB key
CD-ROM drive
3.14 Operating System Support
3.14.1 Windows Compatibility
Intel Corporation and Microsoft Corporation co-author design guides for system designers who
will use Intel processors and Microsoft operating systems. The Hardware Design Guide for
Microsoft Windows 2000 Server, Version 3.0 is intended for systems that are designed to work
with Windows Server class operating systems.
Revision 1.3 103
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
This product supports the Hardware Design Guide for Microsoft Windows 2000 Server, Version
3.0 enterprise requirements.
3.14.2 Advanced Configuration and Power Interface (ACPI)
The primary role of the ACPI BIOS is to supply the ACPI tables. POST creates the ACPI tables
and locates them in extended memory (above 1 MB). The location of these tables is conveyed
to the ACPI-aware operating system through a series of tables located throughout memory. The
format and location of these tables is documented in the publicly available ACPI specifications
(Advanced Configuration and Power Interface Specification, Revision 1.0b and Advanced
Configuration and Power Interface Specification, Revision 2.0).
The BIOS supports both ACPI 2.0 and 1.0b tables. To prevent conflicts with a non-ACPI-aware
operating system, the memory used for the ACPI tables is marked as “reserved” in INT 15h,
function E820h.
As described in the ACPI specifications, an ACPI-aware operating system generates an SMI to
request that the system be switched into ACPI mode. The BIOS responds by setting up all
system specific configurations required to support ACPI and issues the appropriate command to
the BMC to enable ACPI mode. The system automatically returns to legacy mode on hard reset
or power-on reset.
The ACPI specification requires the system to support at least one sleep state. The BIOS
supports S0, S1, S3, S4, and S5 states. S1 is considered a sleep state.
®
Note: S3 is only supported on the Intel Workstation Board S5000XVN. See the server or
workstation Technical Product Specification that applies to your product for more information
about the supported sleep states.
This platform can wake from the S1 state using USB devices in addition to the sources
described in Section 3.16 below.
The wake sources are enabled by the ACPI operating systems with cooperation from the
drivers. The BIOS has no direct control over the wake sources when an ACPI operating system
is loaded. The role of the BIOS is limited to describing the wake sources to the operating
system and controlling secondary control / status bits via the differentiated system description
table (DSDT).
The S5 state is equivalent to operating system shutdown. No system context is saved when
going into S5.
3.15 Front Control Panel Support
The platform supports a power button, a reset button, and an NMI button on the control panel.
3.15.1 Power Button
The BIOS supports a front control panel power button. Pressing the power button initiates a
request that the BMC forwards to the ACPI power state machines in the chipset. It is monitored
by the BMC and does not directly control power on the power supply.
104 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
Power Button — Off to On
The BMC monitors the power button and the wake up event signals from the chipset. A
transition from either source results in the BMC starting the power-up sequence. Since
the processors are not executing, the BIOS does not participate in this sequence. The
hardware receives the power good and reset signals from the BMC and then transitions
to an on state.
Power Button — On to Off (operating system absent)
The System Control Interrupt (SCI) is masked. The BIOS sets up the power button event
to generate an SMI and checks the power button status bit in the ACPI hardware
registers when an SMI occurs. If the status bit is set, the BIOS sets the ACPI power
state of the machine in the chipset to the OFF state. The BMC monitors power state
signals from the chipset and transitions an off state to the power supply. As a safety
mechanism, the BMC automatically powers off the system in 4 to 5 seconds if the BIOS
fails to service the request.
Power Button — On to Off (operating system present)
If an ACPI operating system is running, pressing the power button switch generates a
request via SCI to the operating system to shutdown the system. The operating system
retains control of the system and operating system policy determines the sleep state into
which the system transitions, if any. Otherwise the BIOS turns off the system.
3.15.2 Reset Button
The platform supports a front control panel reset button. Pressing the reset button initiates a
request that the BMC forwards to the chipset. The BIOS does not affect the behavior of the
reset button.
3.15.3 Non-Maskable Interrupt (NMI) Button
The BIOS supports a front control panel NMI button. The NMI button might not be provided on
all front panel designs. Pressing the NMI button initiates a request that causes the BMC to
generate a NMI. The BIOS captures the NMI during boot services time. The operating system
catches the NMI during runtime. During boot services time, the BIOS halts the system upon
detection of the NMI. During runtime, the operating system handles NMIs.
3.16 Sleep and Wake Support
3.16.1 System Sleep States
The platform supports the following ACPI system sleep states:
ACPI S0 (working) state
ACPI S1 (sleep) state
ACPI S3 (suspend) state
ACPI S4 (hibernate) state
ACPI S5 (soft-off) state
®
Note: The S3 state is only supported on the Intel Workstation Board S5000XVN. See the
server or workstation Technical Product Specification that applies to your product for more
information about supported sleep states.
Revision 1.3 105
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
3.16.2 Wake Events / SCI Sources
The server or workstation board supports the following wake-up sources in the ACPI
environment. The operating system controls enabling and disabling these wake sources:
Devices that are connected to any USB port, such as USB mice and keyboards, can
wake the system from the S1 and S3 sleep states.
The serial port can be configured to wake the system from the S1 sleep state.
PCI cards, such as LAN cards, can wake the system from the S1. S3, S4, and S5 sleep
states. The PCI card must have the necessary hardware for this to work.
As required by ACPI specification, the power button can wake the system from the S1
and S3 sleep states.
3.17 Non-Maskable Interrupt Handling
Non-maskable interrupts are generated by two sources: by a front panel NMI button press or by
the BIOS to halt the system upon detecting a system fatal error. The BIOS installs a default NMI
handler that displays a system error message and then halts the system. The BIOS NMI handler
is active during POST and the operating system installs its own handler to handle NMI during
operating system runtime.
When the BIOS NMI handler is active, the BIOS handler detects the source of the NMI and
display a system error message before halting the system. The table below shows the error
messages that may be displayed.
Table 35. NMI Error Messages
NMI Source System Error Message
FP NMI button Front Panel NMI activated - System Halted
System Error NMI NMI has been received - System Halted
3.18 BIOS Server Management
The BIOS supports many standards-based server management features and several proprietary
features. The Intelligent Platform Management Interface (IPMI) is an industry standard and
defines standardized, abstracted interfaces to platform management hardware. This chapter
describes the implementation of the IPMI features.
3.19 IPMI
Intelligent platform management refers to autonomous monitoring and recovery features that
are implemented in platform hardware and firmware. Platform management functions such as
inventory, the event log, monitoring, and system health reporting are available without help from
the host processors and when the server is in a powered down state, as long as AC power is
attached. The baseboard management controller (BMC) and other controllers perform these
tasks independently of the host processor. The BIOS interacts with the platform management
controllers through standard interfaces.
106 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
The BIOS enables the system interface to the BMC in early POST. The BIOS logs system
events and POST error codes during the system operation. The BIOS logs a boot event to BMC
early in POST. The events logged by the BIOS follow the Intelligent Platform Management
Interface Specification, Version 2.0.
3.20 Console Redirection
The BIOS supports redirection of both video and keyboard via a serial link (serial port). When
console redirection is enabled, the local (host server) keyboard input and video output are
passed both to the local keyboard and video connections, and to the remote console through
the serial link. Keyboard inputs from both sources are considered valid and video is displayed to
both outputs.
As an option, the system can be operated without a host keyboard or monitor attached to the
system and run entirely via the remote console. Utilities that can be executed remotely include
BIOS Setup.
3.20.1 Serial Configuration Settings
The BIOS does not require that the splash logo be turned off for console redirection to function.
The BIOS supports multiple consoles, some of which are in graphics mode and some in text
mode.
Console redirection ends at the beginning of the legacy operating system boot. The operating
system is responsible for continuing the redirection from that point.
3.20.2 Keystroke Mappings
During console redirection, the remote terminal sends keystrokes to the local server. The
remote terminal can be a dumb terminal with a direct connection and running a communication
program. The keystroke mappings follow VT-UTF8 format with the following extensions.
3.20.2.1 Setup Alias Keys
The and -function key combinations are synonyms for the or “Setup” key.
They are implemented and documented, but are not be prompted for in screen messages.
These hot keys are defined for console redirection support, and are not be implemented for
locally attached keyboards.
3.20.2.2 Standalone Key for Headless Operation
The Microsoft Headless Design Guidelines describes a specific implementation for the
key as a single standalone keystroke:
followed by a two-second pause must be interpreted as a single escape.
followed within two seconds by one or more characters that do not form a
sequence described in this specification must be interpreted as plus the character
or characters, not as an escape sequence.
The escape sequence in the following table is an input sequence. This means it is sent to the
BIOS from the remote terminal.
Revision 1.3 107
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
Table 36. Console Redirection Escape Sequences for Headless Operation
Escape Sequence Description
RrR Remote Console Reset
This will implement but will default to “disabled”.
3.20.3 Limitations
BIOS Console redirection terminates after an EFI-aware operating system calls EFI Exit
Boot Services. The operating system is responsible for continuing console redirection
after that.
BIOS console redirection is a text console. Graphical data, such as a logo, are not
redirected.
3.20.4 Interface to Server Management
If the BIOS determines that console redirection is enabled, it will read the current baud rate and
pass this value to the appropriate management controller via the Intelligent Platform
Management Bus (IPMB).
3.21 IPMI Serial Interface
The system provides a communication serial port with the BMC. A multiplexer, controlled by the
BMC, determines if the COM1 external connector is electrically connected to the BMC or to the
standard serial port of the Super I/O. See the Intelligent Platform Management Interface
Specification, Version 2.0, Section 14 “IPMI Serial/Modem Interface” for information about these
features.
3.21.1 Channel Access Modes
The BIOS supports the four different channel access modes that are described in table 6-4 of
the Intelligent Platform Management Interface Specification, Version 2.0.
3.21.2 Interaction with BIOS Console Redirection
BIOS Console Redirection accomplishes the implementation of VT-UTF8 console redirection
support in Intel’s server BIOS products. This implementation meets the functional requirements
set forth in the Microsoft Windows 2003* WHQL requirements for headless operation of servers.
It also maintains a necessary degree of backward compatibility with existing Intel server BIOS
products and meets the architectural requirements of Intel server products in development.
The server BIOS has a console that interacts with a display and keyboard combination. The
BIOS instantiates sources and sinks of input / output data in the form of BIOS Setup screens,
Boot Manager screens, Power On Self Test (POST) informational messages, and hot-key /
escape sequence action requests.
Output is displayed locally at the computer on video display devices. This is limited to VGA
displays in text or graphics mode. Local input may come from a USB keyboard. Mouse support
is not available.
108 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System BIOS
The use of serial port console redirection allows a single serial cable to be used for each server
system. The serial cables from a number of servers can be connected to a serial concentrator or
to a switch. This allows access to each individual server system. The system administrator can
remotely switch from one server to another to manage large numbers of servers.
®
Through the redirection capabilities of the BMC on Intel platforms, the serial port UART input /
output stream can be further redirected and sent over a platform LAN device as a packetized
serial byte stream. This BMC function is called Serial over LAN (SOL). It further optimizes space
requirements and server management capability.
Additional features are available if BIOS for console redirection is enabled on the same COM
port as the channel access serial port, and if the Channel Access Mode is set to either Always
Active or Preboot.
BIOS console redirection supports an extra control escape sequence to force the COM port to
the BMC. After this command is sent, the COM1 port attaches to the BMC Channel Access
serial port and Super I/O COM1 data is ignored. This feature allows a remote user to monitor
the status of POST using the standard BIOS console redirection features and then take control
of the system reset or power using the Channel Mode features. If a failure occurs during POST,
a watchdog time-out feature in the BMC automatically takes control of the COM1 port.
The character sequence that switches the multiplexer to the BMC serial port is “ESC O 9”
(denoted as ^[O9). This key sequence is above the normal ANSI function keys and is not used
by an ANSI terminal.
3.22 Wired For Management (WFM)
Wired for Management is an industry-wide initiative to increase overall manageability and
reduce total cost of ownership. WFM allows a server to be managed over a network. The
system BIOS supports the System Management BIOS Reference Specification, Version 2.4 to
help higher-level instrumentation software meet the Wired For Management Baseline
Specification, Revision 2.0 requirements.
3.22.1 PXE BIOS Support
The BIOS supports the EFI PXE implementation as specified in Chapter 15 of the Extensible
Firmware Interface Reference Specification, Version 1.1. To utilize this, the user must load EFI
Simple Network Protocol driver and the UNDI driver specific for the network interface card being
used. The UNDI driver should be included with the network interface card. The Simple Network
Protocol driver can be obtained from http://developer.intel.com/technology/framework.
The BIOS supports legacy PXE option ROMs in legacy mode and includes the necessary PXE
ROMs in the BIOS image for the onboard controllers. The legacy PXE ROM is required to boot
a non-EFI operating system over the network.
3.23 System Management BIOS (SMBIOS)
The BIOS provides support for the System Management BIOS Reference Specification, Version
2.4 to create a standardized interface for manageable attributes that are expected to be
supported by DMI-enabled computer systems. The BIOS provides this interface via data
structures through which the system attributes are reported. Using SMBIOS, a system
Revision 1.3 109
Intel order number D38960-006
System BIOS Intel® S5000 Server Board Family Datasheet
administrator can obtain the types, capabilities, operational status, installation date and other
information about the server components.
110 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4. System Management
4.1 Feature Support
®
This section provides a high-level list of management features supported by the Intel 631xESB
/ 632xESB I/O Controller Hub BMC.
4.1.1 Legacy Features
These features are carried over from previous platforms with little or no change in functionality.
4.1.1.1 IPMI 2.0 Features
See the IPMI 2.0 Specification for more information on the features listed in this section.
Baseboard management controller (BMC) functionality
Watchdog timer
Messaging support – Includes command bridging and user/session support.
Chassis device functionality – Includes power / reset control and BIOS boot flags
support.
Alert processing device – Includes Platform Event Trap (PET) SNMP alerts via LAN
interfaces.
Platform event filtering (PEF) device functionality.
Event receiver device functionality – The BMC receives and processes events from
other platform subsystems.
Field replaceable unit (FRU) inventory device functionality – The BMC supports access
to system FRU devices using IPMI FRU commands.
System event log (SEL) device functionality – The BMC supports and provides access to
a SEL.
Sensor device record (SDR) repository device functionality – The BMC supports storage
and access of system SDRs.
Sensor device and sensor scanning / monitoring– The BMC provides IPMI management
of system sensors. The BMC polls various platform sensors for the purpose of
monitoring and reporting system health. These include soft sensors used for reporting
system state and events, as well as hardware sensor monitoring.
IPMI interfaces:
- Host Interfaces – Includes SMS (with “receive message queue” support) and SMM
interfaces.
- Serial- Interface – Basic mode and terminal mode support.
- PCI-SMBus Interface – Allows plug-in PCI cards to send commands to BMC via
IPMB-like command protocol.
- IPMB Interface
- LAN Interfaces – Supports IPMI over LAN protocol (RMCP, RMCP+)
Revision 1.3 111
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
Serial Over LAN (SOL)
ACPI state synchronization – The BMC tracks ACPI state changes (provided by BIOS).
BMC self test – The BMC performs initialization and run-time self tests and makes
results available to external entities.
4.1.1.2 Non-IPMI Features
This section lists non-IPMI feature support carried over from prior generation of servers.
PSMI 1.44-compliant power system monitoring, including support for power gauge and
power nozzle sensors. Prior generation platforms supported PSMI 1.42, which was very
similar to PSMI 1.44).
Fault resilient booting (FRB) support – FRB2 is supported via watchdog timer
functionality.
BMC firmware update using firmware transfer mode operation
BMC on-line update – BMC rolling update, which supports a redundant firmware image.
Power state retention
Chassis intrusion detection is supported on some platforms
FRU fault LED support – The BMC lights server LEDs to indicate failed components.
Basic fan control using TControl ver.1 SDRs.
Fan redundancy monitoring and support
Power supply redundancy monitoring and support
Hot-swap fan support
Signal testing support – The BMC provides test commands for setting or getting various
platform signal state
Beep code generation – The BMC generates diagnostic beep codes for various fault
conditions
Hot-swap backplane support – The BMC pushes power supply state to HSC
System GUID storage and retrieval
Front Panel management – The BMC controls system fault LED and chassis ID.
Supports secure lockout of certain front panel functionality. Monitors button presses. The
chassis ID can be turned on via front panel button or command.
Power unit management – Support for power unit sensor. This handles power-good
dropout condition.
NMI – Provides commands to set/get NMI source. Supports generation of NMI due to
watchdog timer, IPMI command, or front panel NMI button. Monitors system NMI signal.
®
ARPs – The BMC can send and respond to ARP. This is supported on Intel 631xESB /
632xESB I/O Controller Hub embedded NICs
®
DHCP – The BMC can perform DHCP. This is supported on Intel 631xESB / 632xESB
I/O Controller Hub embedded NICs
112 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.1.2 New Features
®
This section lists features that are being introduced on server boards that use the Intel 5000
Series Chipsets.
Acoustic management – Improved acoustic levels are achieved by including support for
fan profiles using TControl ver2 SDRs.
BMC timeclock sync with SIO RTC – At BMC startup, the BMC reads SIO RTC and
updates its internal timeclock to match.
Chassis intrusion fan interactions – Fans go to high speed when chassis intrusion signal
is asserted. This is provided on platforms that have chassis intrusion support.
® ®
Intel Remote Management Module (Intel RMM) support. This card utilizes its own
®
dedicated NIC (Intel RMM NIC) to provide advanced server management features that
work in conjunction with the BMC. This support includes the following:
®
- BMC usage of Intel RMM NIC via Fast Management Link (FML). The FML is used
as an extra NIC channel to the BMC. The BMC can support IPMI over LAN and SOL
using this interface.
®
- BMC forwarding of event log messages to the Intel RMM.
4.2 Power System
The BMC is not directly in the system power control path but it does have the capability of
blocking power control actions due to front panel power button presses or chipset initiated
power state changes. It can generate power state changes by simulating a front panel power
button press. It monitors both the requested power state from the chipset and the actual power
good state.
Revision 1.3 113
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
The following is a simplified block diagram showing the power and reset signal interconnections
®
to the Intel 631xESB / 632xESB I/O Controller Hub.
®
Figure 26. Intel 631xESB / 632xESB I/O Controller Hub Power / Reset Signals
114 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.3 BMC Reset Control
The following table shows the sources of BMC resets, and the actions by the server and the
BMC as a result.
Table 37. BMC Reset Sources and Actions
Reset Source System Reset? BMC Reset
Standby power comes up No (system is not up yet) Yes
BMC exits firmware update mode No Yes
4.3.1 BMC Exits Firmware Update Mode
The BMC firmware can be updated using firmware transfer commands through the LPC
interface. The BMC automatically enters firmware transfer mode if it detects that the Force
Update signal is asserted during initialization, or if the operation code checksum validation fails.
Upon exit from firmware transfer mode, the BMC resets itself. The BMC will re-synchronize itself
to the state of the processor and power control signals it finds when it initializes.
4.4 System Initialization
4.4.1 Fault Resilient Booting (FRB)
Fault resilient booting (FRB) is a set of BIOS and BMC algorithms and hardware support that,
under certain conditions, allows a multiprocessor system to boot even if the bootstrap processor
(BSP) fails. The intent of the FRB algorithms is to detect BSP failure, disable the failed
®
processor, and reset the server with a different processor as the BSP. For Intel 5000 platforms,
only FRB2 is supported using watchdog timer commands.
4.4.1.1 Processor Disabling
To disable a processor, the BMC asserts the corresponding Processor Disable signal in
conjunction with resetting the system. The signal used for this purpose is specific for the
processor type.
The BMC will enforce that at least one processor always remains enabled. On platforms that
®
use one of the Intel 5000 Series Chipsets, it is not expected that processors will be disabled
except for debug purposes.
4.4.1.2 BSP Identification
The BMC provides positive indication of which processor(s) have been disabled. It does not
indicate which processor is the BSP.
Revision 1.3 115
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.4.1.3 Watchdog Timer Timeout Reason Bits
To implement FRB2, during POST the BIOS determines whether a BMC watchdog timer
timeout occurred on the previous boot attempt. If it finds a watchdog timeout did occur, it
determines whether that timeout was an FRB2 timeout, system management software (SMS)
timeout, or an intentional, timed hard reset.
4.4.1.4 FRB2
FRB2 refers to the FRB algorithm that provides for detection of system failures, such as hangs,
during POST. The BIOS uses the BMC watchdog timer to back up its operation during POST.
The BIOS configures the watchdog timer to indicate that the BIOS is using the timer for the
FRB2 phase of the boot operation.
After the BIOS has identified and saved the BSP information, it sets the FRB2 timer use bit and
loads the watchdog timer with the new timeout interval.
If the watchdog timer expires while the watchdog use bit is set to FRB2, the BMC (if so
configured) logs a watchdog expiration event showing the FRB2 timeout in the event data bytes.
The BMC then hard resets the system, assuming the BIOS selected reset as the watchdog
timeout action.
The BIOS is responsible for disabling the FRB2 timeout before initiating the option ROM scan
and before displaying a request for a boot password. If the processor fails and causes an FRB2
time-out, the BMC resets the system.
As part of its normal operation, BIOS obtains the watchdog expiration status from the BMC. If
this status shows expiration with an FRB2 timer, the BIOS creates an entry in the system event
log (SEL) which indicates an FRB2 failure. It includes the last POST code generated during the
previous boot attempt in the OEM bytes of the event entry. FRB2 failure is not reflected in the
processor status sensor value.
Although an FRB2 failure will cause events to be logged into the SEL, there is no effect on the
front panel LEDs.
116 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.5 Integrated Front Panel User Interface
The BMC incorporates the front panel interface functionality and supports an SSI EB compliant
model. Indicators on supported front panels are LEDs.
4.5.1 Power LED
The green power LED is active when system DC power is on. The power LED is controlled by
the BIOS. The power LED reflects a combination of the state of system (DC) power and the
system ACPI state. The following table shows the states that can be assumed.
Table 38. Power LED Indicator States
State ACPI Power LED
Power off No Off
Power on No Solid on
S4 / S5 Yes Off
S1 Sleep Yes Blink
S3 Sleep Yes Blink
S0 Yes Solid on
4.5.2 System Status LED
The system status LED is a bicolor LED. Green (status) is used to show a normal operation
state or a degraded operation. Amber (fault) shows the platform hardware state and over-rides
the green status.
When the server is powered down (transitions to the DC-off state or S5), the BMC is still on
standby power and retains the sensor and front panel status LED state established prior to the
power-down event.
When AC power is first applied to the system and 5 volt standby power is present, the BMC
controller on the server board requires 15-20 seconds to initialize. During this time, the system
status LED will blink, alternating between amber and green, and the power button functionality
of the control panel is disabled, preventing the server from powering up. Once BMC initialization
has completed, the status LED will stop blinking and the power button functionality is restored
and can be used to turn on the server.
Note: The system status LED state shows the state for the current, most severe fault. For
example, if there was a critical fault due to one source and a non-critical fault due to another
source, the system status LED state would be solid on (the state for the critical fault).
Revision 1.3 117
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
The following table maps the platform state to the LED state.
Table 39. System Status LED Indicator States
Color State Criticality Description
Off N/A Not ready AC power off
Green / Alternating Not ready Pre DC power on – 15-20 second BMC initialization when AC power
Amber Blink is applied to the server. The control panel buttons are disabled until
the BMC initialization is complete.
Green Solid on System OK System booted and ready.
Green Blink Degraded System degraded
Unable to use all of the installed memory (more than one DIMM
installed).
Correctable errors passed the threshold of 10 and system is
migrating to a spare DIMM (memory sparing). This indicates
that the user no longer has spared DIMMs indicating a
redundancy lost condition. Corresponding DIMM LED should
light up.
In mirrored configuration, when memory mirroring takes place
and system loses memory redundancy.
Redundancy loss such as power-supply or fan. This does not
apply to non-redundant sub-systems.
PCI-e link errors
CPU failure / disabled – if there are two processors and one of
them fails
Fan alarm – Fan failure. Number of operational fans should be
more than minimum number needed to cool the system
Non-critical threshold crossed – Temperature and voltage
Amber Blink Non-critical Non-fatal alarm – system is likely to fail
Critical voltage threshold crossed
VRD hot asserted
Minimum number of fans to cool the system not present or
failed
In non-sparing and non-mirroring mode if the threshold of ten
correctable errors is crossed within the window
Amber Solid on Critical, non- Fatal alarm – system has failed or shutdown
recoverable DIMM failure when there is one DIMM present, no good
memory present
Run-time memory uncorrectable error in non-redundant mode
IERR signal asserted
Processor 1 missing
Temperature (CPU ThermTrip, memory TempHi, critical
threshold crossed)
No power good – power fault
Processor configuration error (for instance, processor stepping
mismatch)
118 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.5.3 Chassis ID LED
The chassis ID LED provides a visual indication of a system being serviced. It is toggled by the
chassis ID button
Table 40. Chassis ID LED Indicator States
State LED State
Identify active via button Solid on
Off Off
4.5.4 Front Panel / Chassis Inputs
The BMC monitors the front panel buttons and other chassis signals. The front panel input
buttons are momentary contact switches, which are de-bounced by the BMC processor
firmware.
4.5.4.1 Chassis Intrusion
®
Server platforms that use one of the Intel 5000 Series Chipsets support chassis intrusion
detection. The BMC monitors the state of the chassis intrusion signal and makes the status of
the signal available. If enabled, a chassis intrusion state change causes the BMC to generate a
sensor event message.
The BMC boosts all fans when the chassis intrusion signal is active. Fans return to their
previous level when the chassis intrusion signal is no longer active. This provides sufficient
cooling when a technician has the cover removed while servicing the unit.
4.5.4.2 Power Button
The power button signal is used to toggle system power. The button is activated by a
momentary contact switch on the front panel assembly. This signal is routed to the BMC as a bi-
directional signal that is monitored by the BMC after the BMC de-bounces the signal. It is also
routed to the chipset signal via blocking circuitry that allows the BMC to lock-out the signal. The
chipset responds to the press of the switch, not the release.
If front panel lock-out is enabled and active, the power button does not power the system on or
off. Instead an event message is generated to the system event log (SEL). See section 4.5.5 for
details on secure mode.
Revision 1.3 119
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.5.4.3 Reset Button
An assertion of the front panel reset signal to the BMC causes the system to start the reset and
reboot process, as long as the BMC has not locked-out this input. This assertion is immediate
and without the cooperation from software or the operating system.
The reset button is a momentary contact button on the front panel. Its signal is routed through
the front panel connector to the BMC, which monitors and de-bounces it.
If front panel lock-out is enabled, the reset button does not reset the system. Instead an event
message is generated to the SEL.
4.5.4.4 Diagnostic Interrupt (Front Panel NMI)
As stated in the IPMI 2.0 specification, “a diagnostic interrupt is a non-maskable interrupt or
signal for generating diagnostic traces and ‘core dumps’ from the operating system.” For
®
platforms that use one of the Intel 5000 Series Chipsets, this is an NMI.
The diagnostic interrupt button is connected to the BMC through the front panel connector. A
diagnostic interrupt button press causes the BMC to do the following:
Generate a critical event message.
Generate a system NMI pulse.
After an NMI has been generated by the BMC, the BMC will not generate another until the
system has been reset or powered down.
The BMC automatically clears the OEM 1 message flag and NMI sources whenever it detects a
system reset, or is itself reset. The diagnostic interrupt button is not disabled or otherwise
affected when the system is in front panel lock-out mode.
4.5.4.5 Chassis Identify
The front panel chassis identify button toggles the state of the chassis ID LED. If the LED is off,
then pushing the chassis identify button lights the LED. The LED remains lit until the button is
pushed again.
4.5.5 Front Panel Lock-out Operation
The front panel lock-out feature allows the front panel buttons to be protected against
unauthorized use or access. Front panel lock-out mode is enabled and controlled by the system
BIOS. When front panel lock-out is enabled and active, and a protected front panel button is
pressed, an event is generated.
120 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
Front panel lock-out allows specific front panel buttons to be protected. This protection includes
blocking the buttons and generating violation events if one of the buttons is pressed while the
front panel is in a lock-out state. Support is available only for protecting the front panel power
and reset buttons as a unit. These buttons cannot be individually locked.
The set of buttons that is protected when front panel lock-out mode is active varies, depending
on the system ACPI power state.
Table 41. Secure Mode versus ACPI State
ACPI Power Button Reset Button Diagnostic Interrupt Button ID Button
State (Front Panel NMI)
S0 Protected Protected Unprotected Unprotected
S1 / S3 Unprotected Unprotected Unprotected Unprotected
S4 / S5 Unprotected Unprotected Unprotected Unprotected
2
4.6 Private Management I C Buses
2
The BMC controls multiple private I C buses. The BMC is the sole master on these buses.
4.7 Watchdog Timer
The BMC implements a fully IPMI 2.0 compatible, watchdog timer. See the IPMI specifications
for details. The NMI / diagnostic interrupt specified for an IPMI 2.0 watchdog timer is associated
with an NMI on IA-32 platforms. A watchdog pre-timeout SMI (or equivalent signal assertion) is
®
not supported on platforms that use one of the Intel 5000 Series Chipsets.
4.8 System Event Log (SEL)
The BMC implements the logical system event log as specified in the Intelligent Platform
Management Interface Specification, Version 2.0. The SEL is accessible via all communication
transports. This way, out-of-band interfaces can access SEL information while the server is
down.
The BMC allocates 65,536 bytes (64 KB) of non-volatile storage space for storing system
events. Every system log record is padded with an extra four-byte timestamp that indicates
when the record is deleted, making each SEL record 20 bytes in size. This means there can be
up to 3,276 SEL records stored at a time. An attempt to add a SEL record after 3,276 records
are stored results in a failure, and the out of space completion code is returned.
Revision 1.3 121
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.8.1 Servicing Events
Events can be received while the SEL is being cleared. The BMC implements an event
message queue to avoid the loss of messages. Queued messages are not overwritten.
The BMC recognizes duplicate event messages by comparing sequence numbers and the
message source. For more information, see the IPMI 2.0 Specification. Duplicate event
messages are discarded (filtered) by the BMC after they are read from the event message
queue. This means the queue can contain duplicate messages.
4.8.2 SEL Erasure
SEL erasure is a background process. SEL events that arrive during the erasure process will be
queued until the erasure is complete and then committed to the SEL.
SEL erasure generates an event logging disabled sensor event.
4.8.3 Timestamp Clock
The BMC maintains a four-byte internal timestamp clock used by the SEL and sensor data
record (SDR) sub-systems. This clock is incremented once per second.
4.8.3.1 Clock Initialization and Synchronization
If the BMC loses standby power, then when the power is restored, the BMC reads the real-time
clock (RTC) in the SIO chip and uses this value to update the BMC’s internal system clock. The
clock is used for SEL timestamps and programmed system wake-ups.
The actual system clock used by the BIOS and the operating system is based on a RTC in the
®
Intel 5000 Series Chipsets’ ICH component, not on the component in the SIO that the BMC
uses to initialize its clock. As a result, it is possible for synchronization issues to exist between
the BMC clock and the real-time clock. In some situations, the BIOS updates the BMC clock.
This alleviates possible mismatch problems as described below:
System boot: At each system boot, the BIOS checks the BMC timestamp clock and only
updates this clock if the time is inaccurate. This reduces extra SEL entries.
SMI handler: The BIOS programs the chipset to generate an SMI when the operating
system is shutting down (transition to S3, S4, or S5). This is necessary to download the
sleep state information to BMC. During this SMI, the BIOS will read the time from the
system RTC and then update BMC clock.
Whenever the BMC receives the Set SEL Time command, it updates the private RTC in the SIO
to match the system time. That helps ensure that the BMC RTC is in sync with system RTC.
If the system time (for instance, set through an operating system interface) is changed, the BMC
time clock will not be re-synchronized until the operating system shuts down the server, or, in
case of a non-graceful shutdown, when the server is rebooted.
122 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.9 Sensor Data Record (SDR) Repository
The BMC implements the logical sensor data record (SDR) repository as specified in the
Intelligent Platform Management Interface Specification, Version 2.0 The SDR repository is
accessible via all communication transports. This way, out-of-band interfaces can access SDR
repository information while the system is down.
The BMC allocates 65,536 bytes (64 KB) of non-volatile storage space for the SDR.
4.9.1 Initialization Agent
The BMC implements the internal sensor initialization agent functionality specified in the
Intelligent Platform Management Interface Specification, Version 2.0. When the BMC initializes
upon a system boot, it scans the SDR repository and configures the IPMB devices that have
management controller records. This includes setting sensor thresholds, enabling or disabling
sensor event message scanning, and enabling or disabling sensor event messages.
The initialization process causes those IPMB micro-controllers to rearm their event generation.
In some cases, this causes a duplicate event to be sent to the BMC. The BMC’s mechanism to
detect and delete duplicate events should prevent any duplicate event messages from being
logged.
4.10 Field Replaceable Unit (FRU) Inventory Device
The BMC implements the interface for logical FRU inventory devices as specified in the
Intelligent Platform Management Interface Specification, Version 2.0. This functionality provides
commands used for accessing and managing the FRU inventory information. These commands
can be delivered via all interfaces.
The BMC provides FRU device command access to its own FRU device, and to the FRU
devices throughout the server. The BMC controls the mapping of the FRU device ID to the
physical device. In accordance with the IPMI specification, FRU device 0 is always located on
the server board.
Revision 1.3 123
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.11 Diagnostics and Beep Code Generation
The BMC can generate beep codes upon detection of failure conditions. Beep codes are
sounded each time the problem is discovered, such as on each power-up attempt, but are not
®
sounded continuously. Codes that are common across all platforms that use one of the Intel
5000 Series Chipsets are listed in the following table. Each digit in the code is represented by a
sequence of beeps whose count is equal to the digit.
Table 42. BMC Beep Codes
Code Reason for Beep Associated Sensors Supported?
1-5-2-1 CPU: Empty slot / population error – Processor CPU population error Yes
slot 1 is not populated.
1-5-2-2 CPU: No processors (terminators only) N/A No
1-5-2-3 CPU: Configuration error, such as VID N/A No
mismatch
1-5-2-4 CPU: Configuration error, such as BSEL N/A No
mismatch
1-5-4-2 Power fault: DC power unexpectedly lost (power Power unit – power unit Yes
good dropout) failure offset
1-5-4-3 Chipset control failure N/A No
1-5-4-4 Power control fault Power unit – soft power Yes
control failure offset
4.12 NMI
On IA-32 platforms, the BMC has specific monitoring and signal generation functionality in
regards to the NMI signal. When a diagnostic interrupt is generated by the BMC, the NMI signal
is pulsed. A front panel diagnostic interrupt sensor is used to log SEL events for assertion of the
diagnostic interrupt.
Note: A diagnostic interrupt is also referred to as front panel diagnostic interrupt or NMI /
diagnostic interrupt.
124 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.12.1 Signal Generation
The BMC generates an NMI pulse under certain conditions. The BMC-generated NMI pulse
duration is at least 30 ms. After an NMI has been generated by the BMC, the BMC will not
generate another until the system has been reset or powered down. BMC NMI generation can
be disabled in the system BIOS. The following will cause the BMC to generate an NMI pulse:
The front panel diagnostic interrupt button has been pressed. See section 4.5.4.4 for
more details.
A PEF table entry matching an event where the filter entry indicates a diagnostic
interrupt action.
Watchdog timer pre-timeout expired and a NMI / diagnostic interrupt pre-timeout action
is enabled.
4.13 Processor Sensors
The BMC provides IPMI sensors for processors and associated components, such as voltage
regulators and fans. Most of these sensors are implemented on a per-processor basis.
Table 43. Processor Sensors
Sensor Type Per-Proc Description
Socket
Processor Status Yes Processor presence and fault state
Processor Temperature Yes Temperature from processor itself. This either
represents the TDIODE temperature or platform
environmental control interface (PECI) temperature,
depending on processor family
Processor VRD Over-temperature Yes Discrete sensor that indicates a processor VRD has
Indication crossed an upper operating temperature threshold
Processor Voltage Yes Threshold sensor for voltage from processor voltage
regulator
Processor Voltage Limit Fault Yes Discrete sensor that indicates a processor voltage is out
of range
Processor Fan Speed Yes Speed of processor fan-sink (not always present)
Processor Thermal Control (Prochot) Yes Percentage of time a processor is throttling due to
thermal conditions
CPU Population Error No Improper socket population. This means slot 1 is empty.
Revision 1.3 125
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.13.1 Processor Status Sensors
The BMC provides IPMI sensor of type Processor for monitoring various status information for
each processor slot supported by the platform.
With the exception of the processor presence offset, if an event state (sensor offset) has been
asserted, it will remain asserted until one of the following occurrences:
The processor retest option is enabled in BIOS setup.
A/C power cycle occurs.
DC power-on and system resets do not re-arm processor status sensors.
Table 44. Requirements for Processor Status
Processor Status Detected By
IERR BMC
Thermal trip BMC
1
FRB2 / Hang in POST failure BIOS
Configuration error (for instance, stepping mismatch) BIOS
Processor presence detected BMC
®
Note 1: A fault is not reflected in the processor status sensor on platforms that use one of the Intel 5000 Series
Chipsets
4.13.1.1 Processor Presence
When the BMC detects an empty processor socket, it sets the disable bit in the processor status
for that socket and clears the remaining status bits, including any persistent bits.
Upon BMC initialization, the BMC checks to see if the processor is present. One event should
be logged for processor presence at BMC initialization for each installed processor.
4.13.2 Processor VRD Over-Temperature Sensor
This sensor monitors a signal that indicates if a processor VRD is running over the temperature
limit. The state of this signal is an input into the National Semiconductor* LM94 system
management controller, which asserts the associated Prochot signal and effectively lowers the
VRD temperature. The state of the signal is not an input into the system fan control sub-system.
This relationship is 1:1; if VRD-hot is asserted, then Prochot will assert.
126 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.13.3 ThermTrip Monitoring
The BMC is responsible for persistently retaining ThermTrip history for each processor. This
history tracks whether the processor has had a ThermTrip since the last processor sensor re-
arm or retest.
When a thermal trip occurs, the BMC will poll the ThermTrip status for each processor. If the
BMC has detected that a ThermTrip occurred, then it will set the ThermTrip offset for the
applicable processor status sensor. The system hardware will then attempt to power down the
server.
4.13.4 Platform Enviroment Control Interface (PECI) Support
4.13.4.1 PECI Temperature Value
PECI temperature reading will be the current temperature reading relative to processor throttling
temperature threshold. It is always be less than or equal to 0. As the temperature of the
processor increases, the negative PECI reading will get smaller until it reaches 0 . When the
processor temperature reaches or exceeds the Prochot temperature, the PECI temperature
reading will remain at 0.
4.13.4.1.1 IPMI Sensor Support for PECI
Two temperature sensors per processor: Because these servers and workstations
must support either non-PECI or PECI processors, this will be handled by defining two
IPMI temperature sensors for each processor. One will be for PECI and one for thermal
diode physical sensors. Only two of the temperature sensors will be enabled at a time
(associated with PECI or thermal-diode), dependent on which sensor’s SDR is loaded on
the system. PECI enabled processors only support the PECI SDR. When changing from
non-PECI processors to PECI processors in a system the SDR must be re-loaded to get
an accurate temperature reading.
IPMI sensor readings for PECI: IPMI processor temperature sensors that monitor
thermal-diodes provide an absolute temperature value. However, when PECI processors
are installed, the IPMI processor temperature sensors will provide relative values that
are less than or equal to 0.
Detecting PECI sensors: The PECI sensors will be a type code (01h) = temperature
and have a sensor maximum of 0 degrees C. If software needs to determine if a
temperature sensor is a PECI sensor, it should convert the sensor maximum in the SDR
and verify that the converted sensor maximum is 0 degrees C.
PECI sensor name: The PECI sensors are called Px Therm Margin on Intel S5000
systems, where the 'x' is the processor #. Example: Processor 1 would read P1 Therm
Margin.
PECI thresholds: The PECI sensor will not have any thresholds assigned to this sensor
4.13.5 PROCHOT Support
4.13.5.1 PROCHOT Temperature Sensor
On these servers and workstations, the PROCHOT sensor will be as an indication of the
amount of time the processor spends in a throttled state, over a fixed period of time. Under
normal operation, this sensor will read 0, indicating that the processor is not throttled. As the
Revision 1.3 127
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
processor increases in temperature, the amount of time the processor spends in a throttled
state will increase, until 100% throttling is reached.
4.13.5.1.1 IPMI Sensor Support for PROCHOT
PROCHOT time window: The PROCHOT sensor measures the % of throttling on an
individual processor over a 5.8 second time window.
Detecting PROCHOT sensors: The PROCHOT sensors will be a type code (01h) =
temperature, but is read as a %. This is determined by reading bit 0 of the 'sensor units
1' field of the PROCHOT SDR. If bit 0 of this byte is 1b, then the sensor unit is read as a
%. This is a standard method in IPMI to determine if a sensor is read as a %.
PROCHOT sensor name: The PROCHOT sensors are called Px Therm Ctrl % on Intel
S5000 systems, where 'x' is the processor #. Example: Processor 1 would read P1
Therm Ctrl %.
PROCHOT thresholds: The PROCHOT sensors will have an upper critical threshold
and should be treated as a normal threshold sensor.
4.13.6 IERR Monitoring
The BMC monitors the IERR signal from each processor and maps this to the IERR offset of the
associated processor status sensor.
4.13.7 Dynamic Processor Voltage Monitoring
Processors support dynamic operating states in which the processor VIDs can change under
program control or due to operating conditions. It is not feasible for the BMC to dynamically alter
voltage thresholds for direct monitoring of the processor voltages. However, the National
Semiconductor* LM94 system management controller device supports dynamic monitoring. The
BMC reads a status register from the LM94 system management controller, which indicates if
the processor voltage is within acceptable limits.
4.13.8 Processor Temperature Monitoring
®
Processors used with platforms that use one of the Intel 5000 Series Chipsets are multi-core
and have one physical temperature sensor per core. The BMC aggregates the processor
temperature or temperature offset (PECI enabled processor) sensing into one IPMI temperature
sensor per socket. The higher of the two temperatures is used as the value of the IPMI sensor.
128 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.13.9 Processor Thermal Control Monitoring (Prochot)
The BMC monitors processor thermal control monitoring for each processor. This functionality is
provided by the National Semiconductor* LM94 system management controller device, which
provides a reading of the percentage of time that the processor ProcHot signal is asserted over
a given measurement window. The BMC implements this as a threshold sensor on a per-
processor basis.
4.13.10 CPU Population Error Sensor
The only processor population check that the BMC does is to verify that a processor is installed
in slot 1. The hardware does not allow the server to power up in this state.
At BMC initialization, this sensor is first set to a de-asserted state. The BMC then checks for
CPU population errors and sets the new value accordingly. If an error is detected and the SDR
is so configured, a SEL event will be logged. The BMC checks for this fault condition and
updates the sensor state at each attempt to DC power-on the system. At each DC power-on
attempt, a beep code is generated if this fault is detected. BMC beep codes are listed in Table
42.
Note: This sensor is an auto-re-arm sensor but is not re-armed at system DC power-on or for
system resets. The correct way to clear this sensor state is to correct the problem by AC
powering down the server, installing a processor into slot 1, then AC powering on the server.
4.14 Standard Fan Management
The BMC controls and monitors the system fans. For each fan, there is a fan speed sensor that
provides fan failure detection. Some platforms also provide fan presence detection which the
BMC maps into per-fan presence sensors. See the server or workstation Technical Product
Specification that applies to your product for more information.
It is possible for the BMC to control the speed of some fans. Controllable fans are divided into
fan domains in which there is a separate fan speed control for each domain and a separate fan
control policy configurable for each domain.
A fan domain can have a set of temperature and fan sensors associated with it. These sensors
are used to determine the current fan domain state. A fan domain has three states: sleep,
nominal, and boost. The sleep and boost states have fixed, but configurable, fan speeds
associated with them. The nominal state has a variable speed determined by the fan domain
policy (see section 4.14.1, Nominal Fan Speed). An OEM SDR record is used to configure the
fan domain policy (see Section 4.14.1).
Note: See the server or workstation Technical Product Specification that applies to your product
for more information
The fan domain state is controlled by several factors. The following states are in order of
precedence, from high to low:
Revision 1.3 129
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
Boost:
The associated fan in a critical or non-recoverable state in a non-redundant fan
configuration.
The fan domain is a state of insufficient resources in a redundant fan configuration.
Any temperature sensor in a critical or non-recoverable state, with the exception of
Processor Thermal Control Monitoring sensor (Prochot) or VRD Over-Temperature
(VRDHot) sensors.
Sleep:
No boost conditions, system in ACPI S1 and S3 sleep states, and the BMC is configured
to transition fan domains to sleep state.
Nominal:
See Section 4.14.1.
4.14.1 Nominal Fan Speed
It is possible to configure a fan domain’s Nominal fan speed to be either static (fixed value) or
controlled by the state of one or more associated temperature sensors.
OEM SDR records are used to configure which temperature sensors are associated with which
fan control domains as well as the relationship (algorithm) between the temperature and fan
speed control (PWM) value. Multiple OEM SDRs may reference / control the same fan control
domain and multiple OEM SDRs may reference the same temperature sensors.
The PWM value for the given domain is computed using one or more instances of a stepwise
linear algorithm and a clamp algorithm. The transition from one computed Nominal fan speed
(PWM value) to a new one is ramped over time to avoid audible transitions. The ramp rate is
configurable via the OEM SDR.
Multiple Additive and Clamp Controls can be defined for each fan domain and used
simultaneously. For each domain, the BMC uses the maximum of all of the domain’s Stepwise
Linear Control contributions and the sum of all of the domain’s Clamp Control contributions to
computes the domain’s total PWM value, with the exception that a stepwise linear instance can
be configured to provide the domain maximum at any time.
Hysteresis may be specified to minimize fan speed oscillation and also to smooth out fan speed
transitions. Its application is described along with the fan contribution methods below. If a
legacy TCONTROL SDR format does not allow specifying hysteresis, the BMC will assume a
hysteresis value of zero.
4.14.2 Stepwise Linear
4.14.2.1 Fan Speed Contribution
Each Stepwise Linear TCONTROL sub-record defines a lookup table that maps temperature
sensor readings to fan speeds. The table entries must be in increasing order of temperature.
The BMC walks the table, starting from the end, until it finds a temperature entry that is less
130 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
than or equal to the current reading of the temperature sensor. The corresponding fan speed is
used as the domain fan contribution of that sub-record.
Hysteresis is applied to the difference calculated from the previously used reading to the current
reading. If the difference is positive, the temperature is increasing and the specified positive
hysteresis is subtracted. Otherwise, the change is negative or zero (non-positive), and the
specified negative hysteresis is added.
If factoring in the hysteresis changes the calculated difference from positive to negative, or from
non-positive to positive, the previously calculated contribution is used instead of recalculating
the contribution. This is different from the IPMI sensor threshold interpretation of hysteresis,
which is applied to threshold, but it has the desired effect of preventing oscillating fan speed
behavior.
The basis for the final fan speed for each domain is the maximum of all calculated contributions
of all Stepwise Linear TCONTROL sub-records that are valid under the active profile for that
domain. All currently valid clamp contributions are added to this base value.
4.14.2.2 Domain Maximum
Stepwise Linear TCONTROL sub-records might have a flag set that indicates that the instance
provides the fan domain maximum PWM value. These sub-records do not contribute to the fan
speed as described above. Instead, the fan speed obtained through the table lookup procedure
is saved for later reference. When the final domain contribution is calculated, it will be reduced,
if necessary, to this domain maximum value. Hysteresis is not applied to domain maximum sub-
records.
4.14.3 Clamp
Clamp TCONTROL sub-records specify a single temperature value and direct the BMC to
increase the fan speed for the associated fan domain as necessary to maintain the value of the
corresponding temperature sensor below the clamp value. When the sensor reading exceeds
the clamp value, the fan speed contribution will increase over time until either the fan speed
reaches maximum speed or the temperature reduces to below the threshold. If the temperature
is below the threshold, the sensor’s contribution will be reduced over time until it goes to zero.
Fan speed changes occur in the step size specified in the sub-record.
These sub-records allow a scan rate to be specified that will lower the frequency at which the
sub-record’s contribution is recalculated. This can be used to allow time for the fan domain to
react and increase the system cooling before increasing the fan speed again.
Hysteresis, if specified, is only applied when the contribution direction might change from
positive to negative or vice versa. e.g., if the BMC previously increased the fan speed
contribution from a given clamp sub-record, it will factor in any specified negative hysteresis
when determining whether the “change direction” and start decreasing the fan contribution. If no
action is taken due to hysteresis, the BMC continues to remember the previous direction.
The sum for all calculated contributions of all Clamp TCONTROL sub-records that are valid under
the currently active profile for that domain will be added to the maximum of all currently valid
stepwise linear contributions.
Revision 1.3 131
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.14.4 Sleep State Fan Control
Using the Set ACPI Configuration Mode command, the BMC may be configured to set the fans
to a fixed sleep state speed when the system is in the S1 sleep state.
4.14.5 Fan Redundancy Detection
The BMC supports redundant fan monitoring and implements fan redundancy sensors. A fan
redundancy sensor generates events when it’s associated set of fans transition between
redundant and non-redundant states, as determined by the number and health of the
component fans.
A single fan failure, or removal of a fan from a chassis that supports hot swap fans, in a
redundant fan configuration is a non-critical failure and will be reflected in the front panel status
as such.
4.14.6 Hot Swap Fan Support
Some chassis and server boards provide support for hot-swap fans. These fans can be
removed and replaced while the system is operating normally. The BMC implements fan
presence sensors for each hot swappable fan. When a fan is replaced, the fan speed for the
domain is temporarily set to high (kick-start) to ensure proper fan starting.
Note: See the server or workstation Technical Product Specification that applies to your product
for more detailed information
4.15 Acoustic Management
Acoustic management refers to enhanced fan management to keep the system optimally cooled
while not creating unnecessary noise.
4.15.1 Fan Profiles
The system can be configured through a BIOS setup screen option to give preference to meet
the target acoustic level for the system at the expense of system performance, or to provide
enhanced system performance at the expense of louder fans. This is accomplished with fan
profiles. At the system boot, the BIOS will query the BMC to determine what fan profiles are
supported. The BIOS indicates the chosen setup screen option to the BMC.
4.15.2 Interactions with DIMM Thermal Management
4.15.2.1 Thermal Profile Data
The BIOS requires knowledge of various characteristics to use as input into its calculations for
DIMM throttling setup. This is dependent on which fan profile is enabled. The BIOS retrieves
this platform-specific information from the BMC at system boot.
The BMC supports this with Thermal Profile Data SDRs, which allow this data to be stored in
the BMC’s SDR repository and can be customized per platform and per fan domain. On
systems that support multiple profiles, each Thermal Profile SDR can apply to one or more
profiles in a given fan domain.
132 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.16 PSMI Support
®
Platforms that use the Intel 5000 Series Chipsets support PSMI v1.44 compliant power
supplies. Some power supplies may not support certain optional features, such as current
monitoring.
4.17 System Memory RAS and Bus Error Monitoring
System memory and bus error monitoring is done by the system BIOS. At startup, the BIOS
checks the chipset for any memory errors early in the boot process. The BIOS updates the
status of RAS configuration at startup and later at run time. BMC monitors and logs SEL events
based on the SDR definitions. In addition, the BIOS help the BMC maintain the current DIMM
presence and failure state and current memory RAS configuration (e.g., sparing, mirroring,
RAID).
Support is provided for monitoring errors on system buses such as system bus errors and PCI
bus errors. These are monitored by the BIOS, which generates critical interrupt sensor SEL
events when the errors are detected.
The supported sensors are described below.
4.17.1 SMI Timeout Sensor
For IA-32-based systems, the BMC supports an SMI Timeout Sensor (sensor type OEM (F3h),
event type Discrete (03h)) that asserts if the SMI signal has been asserted for longer than a
fixed time period (nominally 90 seconds for S5000 platforms). A continuously asserted SMI
signal is an indication that the BIOS cannot service the condition that caused the SMI. This is
usually because that condition prevents the BIOS from running.
When an SMI timeout occurs, the BMC takes the following actions:
It asserts the SMI timeout sensor and logs a SEL event for that sensor.
It does an after-crash (post-mortem) system scan for uncorrectable memory and front-
side bus errors. Any uncorrectable ECC errors detected will be logged against a Memory
sensor. Any uncorrectable bus errors will be logged against a Critical Interrupt sensor.
The standard behavior for BMC core firmware is to not initiate a system reset upon detection of
an SMI timeout. This will be followed for S5000 platforms.
The BMC supports sensors for reporting post-mortem system memory errors and for DIMM
presence, disabled state, and failure.
4.17.2 Memory Sensor
The BMC supports one or more Memory type (0Ch) sensors that are event only. The sensors
are only logged against by BMC detected errors (post-mortem) due to an SMI timeout event.
Events will be event type specific (reading code 6Fh). The supported sensor offsets are:
01h – Uncorrectable ECC
Revision 1.3 133
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.17.3 Critical Interrupt Sensor
The BMC implements a Critical Interrupt (13h) sensor for reporting the following conditions /
events:
Bus Uncorrectable Error: Only sensed after an SMI timeout (post-mortem)
Front Panel NMI / diagnostic interrupt: Monitored during normal system operation
4.17.4 DIMM Status Sensors
There is one DIMM status sensor per DIMM slot. These sensors are IPMI sensor type Slot /
Connector (21h) and event / reading type Sensor Specific (6Fh). The supported offsets are:
00h Fault Status Asserted
02h Device Installed
08h Device Disabled
09h Slot Holds Spare Device
The BIOS can set or clear individual offsets for the DIMM sensors using the Set DIMM State
command and Get DIMM State commands.
If the BMC is so configured, the BMC stores the DIMM fault and disabled status will be stored
persistently in non-volatile storage. They are re-established at BMC startup.
The state is not stored persistently.
4.17.4.1 Fault Status
The BIOS detects the DIMM fault status and sets the DIMM sensor state when the BIOS detects
an uncorrectable ECC error
4.17.4.2 Device Installed
The BIOS performs DIMM presence detection and sets the DIMM sensor state appropriately at
each system boot.
4.17.4.3 Device Disabled
The BIOS can determine if a FBDIMM should be disabled and sets the DIMM sensor state
4.17.4.4 Slot Holds Spare Device
The DIMM sparing indication is informational and used by the memory redundancy features to
determine the redundancy state.
134 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.17.4.5 Deassertion of Offsets
The BMC will de-assert (reset) the DIMM fault and / or disabled state for the following reasons:
The BMC receives the Set DIMM State command instructing it to de-assert either or both
of these states.
A DIMM slot becomes empty
A ReArm Sensor command is executed for that DIMM sensor
A ReArm DIMMs command is executed.
DIMM grouping
4.17.4.6 DIMM Grouping
The following table provides the grouping of FBDIMMs.
Figure 27. DIMM Grouping
DIMM Sensor Sensor
Number
DIMM 1A EOh
DIMM 2A E1h
DIMM 1B E2h
DIMM 2B E3h
DIMM 1C E4h
DIMM 2C E5h
DIMM 1D E6h
DIMM 2D E7h
4.17.5 System Memory Redundancy Monitoring
®
The Intel 5000 Series Chipsets support memory redundancy features that go beyond single bit
error correction, allowing failing or failed DIMMs to be managed on-line without affecting normal
system operation. BMC support for these is indicated in the following sections.
Note: See the server or workstation Technical Product Specification that applies to your product
for more information.
Revision 1.3 135
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.17.5.1 DIMM Sparing
With DIMM sparing, the BMC will implement two sensors per DIMM sparing domain (the set of
DIMMs which share a spare set of DIMMs). Each sparing domain will have an associated
unique Entity ID. Both sensors will belong to that Entity.
DIMM sparing redundancy sensor
Sparing redundancy is determined by the BIOS. The BIOS conveys this state to the
BMC. The BMC then sets the state of the associated sensor for the specific sparing
domain appropriately.
This sensor is of type Availability Status (0Bh) and indicates whether the domain is
redundant or not (i.e., whether there are spare DIMM(s) available for use). The
supported offsets are:
- 00h – Fully redundant
Both operational and enabled DIMMs and spares in domain
- 01h – Redundancy lost: Sufficient resources, from redundant
Operational and enabled DIMMs in domain and no spares
- 05h – Non-redundant: Insufficient resources
No operational or disabled DIMMs in domain
DIMM sparing enabled
DIMM sparing is enabled by the BIOS and this configuration is set in the BMC The BMC
then sets the state of the associated sensor for the specific sparing domain
appropriately.
This sensor is used to communicate the enabled state of the sparing feature for the
associated domain. The sensor is of type Entity Presence (25h). This state of this sensor
indicates whether the DIMM Sparing Redundancy sensor should be ignored. The
supported offset is:
- 00h – Entity present
If asserted, indicates that the DIMM sparing feature for this domain is enabled and
the associated DIMM Sparing Redundancy Sensor state is valid. If not asserted,
then the DIMM Sparing Redundancy Sensor should be ignored.
- 01h – Entity absent
If asserted, indicates that the DIMM sparing feature for this domain is not available
and the associated DIMM Sparing Redundancy Sensor state is invalid. This offset is
mutually exclusive with offset 00h - Entity Present.
Note: See the server or workstation Technical Product Specification that applies to your product
for more detailed information
4.17.5.2 Memory Mirroring
If a specific platform supports memory mirroring, the BMC will implement two sensors per
memory mirroring domain (the DIMMs that form a mirrored set). Each mirroring domain will have
an associated unique entity ID. Both sensors will belong to that entity.
136 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
Memory mirroring redundancy sensor
Memory mirroring redundancy is determined by the BIOS. The BIOS conveys this state
to the BMC. The BMC then sets the state of the associated sensor for the specific
mirroring domain appropriately.
This sensor is of type Availability Status (0Bh) and indicates whether the domain is
redundant or not (i.e., whether all mirrored DIMM(s) are available for use). The
supported offsets are:
- 00h – Fully redundant
All DIMMs in mirrored domain operational and enabled.
- 01h – Redundancy lost : Sufficient resources
One or more failed DIMMs in one of the mirror pairs
- 05h – Non-redundant : Insufficient resources
Non-operational DIMMs in both of the mirror pairs
Memory mirroring enabled
Memory mirroring is enabled by the BIOS and this configuration is set in the BMC. The
BMC then sets the state of the associated sensor for the specific mirroring domain
appropriately.
This sensor is used to communicate the enabled state of the mirroring feature for the
associated domain. The sensor is of type Entity Presence (25h). This state of this sensor
indicates whether the Memory Mirroring Redundancy sensor should be ignored. The
supported offset is:
- 00h – Entity present
If asserted, indicates that the memory mirroring feature for this domain is enabled
and the associated memory mirroring redundancy sensor state is valid. If not
asserted, then the memory mirroring redundancy sensor should be ignored.
- 01h – Entity absent
If asserted, indicates that the memory mirroring feature for this domain is not
available and the associated memory mirroring redundancy sensor state is invalid.
This offset is mutually exclusive with offset 00h – Entity present.
Note: See the server or workstation Technical Product Specification that applies to your product
for more detailed information
Revision 1.3 137
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.17.6 System Memory Monitoring and System Boot
The following sequence of events describes the system booting process with respect to the
system memory monitoring feature.
During system boot, BIOS will determine the DIMM population and set this state in the
BMC. The BMC initializes the DIMM sensor state based on the discovered presence
information and persistent fault information.
BIOS will configure memory, disabling DIMMs as necessary and configure the RAS
features as required. The BIOS communicates the set of disabled DIMMs to the BMC
and the BIOS then communicates the RAS feature configuration (enabled / disabled
features) to the BMC.
The BIOS will then notify BMC to any one of the three redundancy states as defined in
section 4.17.5.1.
The BIOS will test the memory. For any memory errors that cause the BIOS to disable a
DIMM or generate an error event, the BIOS will notify the BMC of DIMM failure.
The BIOS must enable BMC system memory error monitoring.
4.18 PCI Express* Support
4.18.1 PCI Express Link Sensors
The BMC implements a series of sensors of IPMI type Critical Interrupt that are used to log run-
time PCI Express link errors detected by the BIOS. An entity ID in the SDR records associates
the errors with PCI Express per the IPMI entity ID definitions.
When the BIOS detects an error, it communicates this to the BMC.
If an error state is asserted on one of the PCI Express* sensors, the BMC will set the Front
panel fault LED to indicate a degraded condition. The sensor state is deasserted for the
following reasons:
The sensor is rearmed through an IPMI command.
The system is reset or powered-on.
Deassertion of the sensor state will remove that state as a contribution to the front panel fault
LED.
4.18.2 BMC Self-test
The BMC performs various tests as part of its initialization. If a failure is determined (e.g.,
corrupt BMC SDR), the BMC stores the error internally. BMC or BMC sub-system failures
detected during regular BMC operation may also be stored internally.
138 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.19 Field Replaceable Unit (FRU) / Fault LED Control
Several sets of FRU / POST / fault LEDs are supported. Some LEDs are owned by the BMC
and some by the BIOS.
The BMC owns control of the following FRU / fault LEDs:
Fan fault LEDs: There is a fan fault LED associated with each fan. The BMC will light a
fan fault LED if the associated fan tach sensor has a lower critical threshold event status
asserted. Fan tach sensors are manual rearm sensors, therefore once the lower critical
threshold has been crossed, the LED will remain lit until the sensor is rearmed. These
sensors are rearmed at system DC power-on and system reset.
CPU fault LEDs: There is a CPU fault LED associated with each processor slot. The
BMC will light a CPU fault LED when the associated processor status sensor detects
either configuration error or processor disabled. Processor status sensors are manual
rearm sensors, therefore once either of these circumstances are detected, the LED will
remain lit until the sensor is rearmed. These sensors are NOT rearmed at system DC
power-on and system reset.
4.20 Hot-swap Backplane (HSBP) Support
The following is a list of BMC – HSC interactions.
BMC initialization agent configures HSC sensors. This occurs when the system is DC
powered-on or reset.
Commands may be bridged through the BMC to the HSC via the IPMB. This is typically
used by system software to access HSC status or to update the HSC firmware.
The HSBP, including the HSC, does not have power applied when the system is in the power-
off (S0 sleep) state. Therefore when the system transitions to the DC power-on state, the HSC
must reach an initialized state before communication with the BMC is possible.
® ®
4.21 Intel Remote Management Module (Intel RMM) Support
® ®
The Intel Remote Management Module (Intel RMM) provides keyboard, video, mouse (KVM)
redirection capability and other advanced functionality. This section describes specific BMC
®
support for the Intel RMM add-in card.
4.21.1 Discovery Sequence
The server board BMC supports a set of commands for setting and retrieving configuration
®
information related to the server board support for the Intel RMM. These commands are
primarily used by the add-in card when power is first applied to the card. They query the BMC to
discover platform support for the add-in connector.
®
The Intel RMM uses this information to adapt to the specific connector support, to form a
complete description of the network connectivity options available, and as the first step in
reconfiguring the BMC according to its own configuration requirements.
Revision 1.3 139
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
®
The BMC provides configuration command interfaces when used with an Intel RMM. This is
done through a combination of IPMI and IPMI OEM commands. The BMC does not
®
automatically handle this configuration. It relies on the Intel RMM to discover the BMC add-in
®
support and then to configure the BMC according to the Intel RMM requirements. Typically, the
®
Intel RMM would have been previously configured by a software utility.
4.21.2 Division of Network Traffic
®
Server management network traffic is handled either by the Intel RMM or by the BMC,
depending on the physical configuration. This is described in the two sub-sections below. The
®
BMC only handles IPMI-over-LAN traffic, including SOL traffic, even if no Intel RMM is
®
installed. The Intel RMM handles TCP/IP traffic. Other basic protocols are routed depending on
®
the BMC and / or Intel RMM configuration.
®
4.21.2.1 Third NIC Channel Interface to Intel RMM
® ® ®
The Intel RMM supports a dedicated NIC, the Intel RMM NIC. The Intel RMM owns routing
the network packets received over this interface. IPMI-over-LAN traffic, including SOL traffic,
®
received by the Intel RMM through this NIC is forwarded to the BMC over an FML or SMBus
®
data link. The Intel RMM handles other server management traffic autonomously.
The BMC supports this mode of operation through the fast management link (FML) network
interface (FNI). This is a high-speed serial interface that provides the data link between the
® ®
Intel RMM and the Intel 631xESB / 632xESB I/O Controller Hub BMC. When the feature is
enabled, the BMC treats this data flow as a third LAN-based IPMI channel, in addition to the two
®
Intel 631xESB / 632xESB I/O Controller Hub-embedded NICs, and any IPMI response data is
sent back over the FML bus as necessary. The FNI mode of operation is disabled when the
BMC is reset due to a loss of standby power.
®
The BMC does not require the Intel RMM to reassemble IP fragments before forwarding them,
®
but it is necessary for the Intel RMM to do so to identify the UDP or TCP port that is targeted
by the IP payload.
4.21.3 Event Forwarding
®
The BMC supports sending notification to the Intel RMM when certain events occur within the
BMC’s domain. This is implemented by the event forwarding mechanism. Event forwarding is a
capability that enables the BMC to forward to an add-in controller a copy of event information
that it internally generates or receives from a Platform Event message.
The following sub-sections describe BMC behavior when the event forwarding feature is
enabled. The formats of the event record data for forwarded events are based on the SEL event
records and OEM SEL record formats defined in Tables 32-1 and 32-2 of the IPMI 2.0
Specification.
140 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.21.3.1 SEL Forwarding
When BMC SEL events are generated through any mechanism other than the Add SEL Entry
®
command, the BMC will send time-stamped copies of these events to the Intel RMM). Events
are forwarded even if the BMC’s SEL is full.
4.21.3.2 BMC Status Change Forwarding
The BMC sends notifications of other status change events that may be of interest to the
registered add-in device. The BMC does not require the add-in device to take any action based
on the event data.
4.21.4 Serial Routing
The BMC provides support for the optional IPMI command, Set Serial Routing Mux, which
supports implementations where an add-in card can take over responsibility for serial port
sharing from the BMC. The command enables an add-in card or adjunct management controller
to direct the BMC to route serial connections to the add-in card or to allow the connections to be
handled by the BMC. Logically, this action can be viewed as controlling a hardware multiplexer
(serial routing mux) that routes the serial signals between the BMC and the add-in card,
although this specification does not describe or require a particular hardware implementation for
supporting this capability.
4.21.4.1 Serial Routing and SOL
SOL may be supported by either the BMC, using SOL in accordance with the IPMI 2.0
® ® ®
Specification, or by the Intel RMM using Telnet. For the Intel RMM-based method, the Intel
RMM must gain control of the serial mux from the BMC.
If the BMC is utilizing its UART interface when the command is received (for instance for BMC-
based SOL or EMP) then it will immediately close the session and the serial channel will appear
as disabled.
®
SOL cannot be routed through both the Intel RMM and the BMC simultaneously.
4.21.5 Messaging Interfaces
This section describes the supported BMC communication interfaces:
Host SMS Interface via low pin count (LPC) / (KCS) interface
Host SMM Interface via low pin count (LPC) / keyboard controller style (KCS) interface
2
Intelligent platform management bus (IPMB) I C interface
PCI SMBus
Emergency management port (EMP) using the IPMI over Serial / Modem protocols for
serial remote access.
LAN interface using the IPMI-over-LAN protocols
Revision 1.3 141
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
These specifications are defined in the following sub-sections. Section 4.26 talks about basic
characteristics of the communication protocols used in all of the above interfaces.
4.22 Channel Management
Every messaging interface is assigned an IPMI channel ID by IPMI 2.0. Commands are
provided to configure each channel for privilege levels and access modes. The following table
shows the standard channel assignments:
Table 45. Standard Channel Assignments
Channel ID Interface Supports
Sessions
0 IPMB No
1 LAN 1 Yes
1
2 LAN 2 Yes
1 ® ® ®
3 LAN 3 (Intel Remote Management Module (Intel RMM) / Intel RMM NIC) Yes
4 EMP (Basic / PPP) Yes
5 Reserved –
1
6 PCI SMBus No
7 SMM No
2
0Eh Self –
0Fh SMS / Receive Message Queue No
Notes:
1. If supported by the server platform.
2. Refers to the actual channel used to send the request.
4.23 User Model
The BMC supports the IPMI 2.0 user model including User ID 1 support. 15 user IDs are
supported. These 15 users can be assigned to any channel.
4.24 Session Support
The BMC supports a total of five simultaneous sessions. This is shared across all session-
based channels.
4.25 Media Bridging
The BMC supports bridging between the EMP and IPMB interfaces, and between the LAN and
IPMB interfaces. This allows the state of other intelligent controllers in the chassis to be queried
by remote console software. Requests may be directed to controllers on the IPMB, but requests
originating on the IPMB cannot be directed to the EMP or LAN interfaces.
142 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.26 Host to BMC Communication Interface
4.26.1 LPC / KCS Interface
The BMC has three 8042 keyboard controller style (KCS) interface ports as described in the
IPMI 2.0 specification. These interfaces are mapped into the host I/O space and accessed via
the chipset low pin count (LPC) bus.
These interfaces are assigned with the following uses and addresses:
Table 46. Keyboard Controller Style Interfaces
Name Use Address
SMS Interface SMS, BIOS POST, and utility access 0CA2h – 0CA3h
SMM Interface SMI handling for error logging 0CA4h – 0CA5h
The BMC gives higher priority to transfers occurring through the server management mode
(SMM) interface. This provides minimum latency during SMI accesses. The BMC acts as a
bridge between the server management software (SMS) and the IPMB interfaces. Interface
registers provide a mechanism for communications between the BMC and the host system.
Most platforms implement the interfaces as host I/O space mapped registers. The interfaces
consist of three sets of two 1-byte-wide registers.
4.26.2 Receive Message Queue
The receive message queue is only accessible via the SMS interface since that interface is the
BMC’s host / system interface. The queue size is platform-dependent, but is guaranteed to be at
least two entries in size. It does not support the IPMI 2.0 suggested implementation of providing
per-channel queue slots to avoid starvation.
4.26.3 Server Management Software (SMS) Interface
The SMS interface is the BMC host interface. The BMC implements the SMS KCS interface as
described in the IPMI 2.0 specification.
4.26.4 SMM Interface
The SMM interface is a KCS interface that is used by the BIOS when interface response time is
a concern, such as with the BIOS SMI handler. The BMC gives this interface priority over other
communication interfaces.
Only a relatively small subset of BMC commands is supported through the SMM interface. In
addition to utilizing the faster SMM interface, the code to execute these commands is optimized
so that the command is executed and responded to during a single BMC interrupt.
Revision 1.3 143
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.27 IPMB Communication Interface
2
The IPMB is a communication protocol that utilizes the 100 KB/s version of an I C bus as its
2
2
physical medium. For more information on I C specifications, see The I C Bus and How to Use
It. The IPMB implementation in the BMC is compliant with the IPMB v1.0, revision 1.0.
The BMC both sends and receives IPMB messages over the IPMB interface. Non-IPMB
messages received via the IPMB interface are discarded.
For IPMB request messages originated by the BMC, the BMC implements a response timeout
interval of 60 ms and a retry count of 3.
4.27.1 PCI System Management Bus (SMBus)
BMC access to the PCI SMBus is supported. The BMC supports a form of IPMB messaging on
the PCI SMBus for which the packet format has been modified to help to remove ambiguity
between IPMB and SMBus traffic.
The following differences exist between this modified packet format and the standard IPMB:
The first IPMB checksum is set to 00h.
The second IPMB checksum is replaced with a Packet Error Code (PEC) which is a
CRC-8 error-checking byte.
2
4.27.2 BMC as I C Master Controller on IPMB
2
The BMC allows access to devices on the IPMB as an I C master. The following commands are
supported:
2
Send Message: This command writes data to an I C device as master.
2
Master Write-Read I C: This command allows the following actions:
2
- Writing data to an I C device as a master.
2
- Reading data from an I C device as a master.
2 2
- Writing data to I C device as a master, issue an I C Repeated Start, and reading a
2 2
specified number of bytes from I C device as a master. Errors in I C transmission or
reception are communicated via completion codes in the command response.
2
These functions support the most common operations for an I C master controller. This includes
2
access to common non-intelligent I C devices like SEEPROMs. The Send Message command
is normally used to send IPMB messages to intelligent devices that utilize the IPMB protocol.
144 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.27.3 IPMB LUN Routing
The BMC can receive either request or response IPMB messages. The treatment of these
messages depends on the destination logical unit number (LUN) in the IPMB message. For
IPMB request messages, the destination LUN is the responder’s LUN. For IPMB response
messages, the destination LUN is the requester’s LUN. The disposition of these messages is
described in the following table. The BMC accepts LUN 00b and LUN 10b.
IPMB messages can be up to 36 bytes, including IPMB header and checksums.
Table 47. BMC IPMB LUN Routing
LUN Name Message Disposition
00b BMC Request messages with this LUN are passed to the BMC command handler for execution.
Response messages with this LUN are compared with outstanding BMC originated requests. If
there is a match, the BMC sub-system that sent the request is notified. Otherwise the message
is discarded.
01b Reserved Reserved – All messages arriving with this LUN are discarded.
10b SMS All messages arriving with this destination LUN are placed in the Receive Message Queue. If
that buffer is full, the message is discarded. No further processing or response is done.
11b Reserved Reserved – All messages arriving with this LUN are discarded.
Revision 1.3 145
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
Figure 8 shows a logical block diagram of the BMC receiving IPMB messages.
IPMB
I2C INTERFACE
IPMB MSG VERIFICATION
LUN ROUTING
LUN=00b
LUN=10b
(SMS) (BMC)
BMC IPMB Other BMC
RECEIVE
MSG Handler Commands
MSG QUEUE
SMS_ATN Get Msg
Flag Cmd
Event Message SEL
SMS Interface
Buffer DEVICE
SMM_ATN Read Event
Flag Msg
SMM Interface
Figure 28. BMC IPMB Message Reception
146 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.28 Emergency Management Port (EMP) Interface
The EMP interface is the Intel implementation of the IPMI 2.0 IPMI over serial feature. The
primary goal of providing an out-of-band RS232 connection is to give system administrators the
ability to access low-level server management firmware functions by using commonly available
tools. To make it easy to use and to provide high-compatibility with LAN and IPMB protocols,
this protocol design adopts some features of both protocols.
The Intel implementation shares the EMP function with the platform’s Serial B interface. The
BMC has control over which agent (BMC or system) has access to Serial B port. Hardware
handshaking, and the the Ring Indicate and Data Carrier Detect signals are supported.
The basic mode of IPMI over serial is supported and is available whether or not DC power is on.
Additional details on the IPMI over serial / modem interface is available in the IPMI 2.0
specification.
4.28.1 COM2 Port Switching
As specified in the IPMI 2.0 specification, if EMP is enabled, then the BMC will watch the serial
traffic when the COM2 port is owned by the system. This is done to respond to in-band port
switching requests. Serial traffic snooping is done in basic mode, although the exact sequences
recognized in the two modes is different.
4.28.2 Basic Mode
Basic mode uses a protocol in which IPMI requests are transmitted over the serial port with
minimum framing, providing a low overhead implementation. Command receipt by the BMC is
acknowledged on a per-packet basis.
Basic mode minimumly supports None (un-authenticated) and Straight Password / Key
authentication types. Callback is supported in basic mode.
4.28.3 Terminal Mode
The BMC supports terminal mode as specified in the IPMI 2.0 specification. Terminal mode
provides a printable ASCII text-based mechanism for delivering IPMI messages to the BMC
over the serial channel or any packet-based interface. Messages can be delivered in two forms:
Via hex-ASCII pair encoded IPMI commands
Via text SYS commands
Revision 1.3 147
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.28.3.1 Input Restrictions
4.28.3.1.1 Maximum Input Length
The BMC supports a maximum of 122 characters per line. The BMC will stop accepting new
characters and stop echoing input when the 122-character limit is reached. However, selected
characters will continue to be accepted and handled appropriately even after the character limit
is reached. These are the , / , illegal, and input
characters.
4.28.3.1.2 Maximum IPMI Message Length
The terminal mode interface supports a maximum IPMI message length of 40 bytes.
4.28.3.1.3 Line Continuation Character
The line continuation character is supported over the serial channel in terminal mode only. The
line continuation character is supported for both hex-ASCII and text commands.
4.28.3.2 Command Support
4.28.3.2.1 Text Commands
The BMC supports all the text commands described in the IPMI 2.0 specification and the OEM
text commands described in the following table.
Table 48. Terminal Mode Commands
Command Request, Response Data Privilege Description
SYS PWD As defined by the IPMI 2.0 specification Callback All IPMI defined variations of this
command supported
SYS TMODE As defined by the IPMI 2.0 specification Callback
SYS SET BOOT As defined by the IPMI 2.0 specification Admin
SYS SET BOOTOPT As defined by the IPMI 2.0 specification Admin
SYS GET BOOTOPT As defined by the IPMI 2.0 specification Operator
SYS SET TCFG As defined by the IPMI 2.0 specification Admin All IPMI defined variations of this
command supported
SYS RESET As defined by the IPMI 2.0 specification Operator
SYS POWER ON As defined by the IPMI 2.0 specification Operator
SYS POWER OFF As defined by the IPMI 2.0 specification Operator
SYS HEALTH QUERY As defined by the IPMI 2.0 specification User All IPMI defined variations of this
command supported
XX XX ... Hex ASCII encoded IPMI commands – Varies Privilege as defined for specific
Request / Response Data as defined in other encoded IPMI command.
command tables.
148 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.28.3.2.2 Text Command Privilege Levels
The BMC supports the privilege level scheme for terminal mode text commands as specified in
Table 48.
4.28.3.3 Bridging Support
The BMC supports the optional bridging functionality described in the IPMI 2.0 specification.
4.28.4 Invalid Password Handling
If three successive invalid Activate Session commands are received on the EMP interface, the
BMC will send the hang-up sequence if in modem mode and delay 30 seconds before accepting
another Activate Session command. The BMC will also log an Out-of-band Access Password
Violation event to the system event log each time an invalid Activate Session command is
received.
4.28.5 Serial Ping Message Behavior
The BMC outputs the IPMI 2.0 specification Serial Connection Active command, or serial ping,
over the serial connection once every two seconds when basic mode is enabled in the EMP
configuration settings. However, serial ping message behavior can vary depending on the types
of operating modes enabled.
4.28.5.1 Operating Mode (Connection Mode Enable) Auto-detection
If basic mode and at least one other operating mode are enabled, and the BMC is currently
auto-detecting the operating mode, the BMC outputs the serial ping until an operating mode is
detected. If the operating mode detected is not basic mode, the serial pings are automatically
disabled. Upon connection loss, session loss, or session closure, the serial pings are
automatically re-enabled based upon the EMP configuration settings.
4.28.5.2 Terminal Mode
If terminal mode is the only operating mode enabled in the EMP configuration settings, the serial
ping is automatically disabled, regardless of the EMP configuration settings. If the EMP
configuration changes, the serial ping message behavior will automatically be re-evaluated as
necessary.
Revision 1.3 149
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
4.29 LAN Interface
The BMC implements both the IPMI 1.5 and IPMI 2.0 messaging models. These provide out-of-
band local area network (LAN) communication between the BMC and the external world.
The BMC supports a maximum of three LAN interfaces:
®
Two of the LAN interfaces utilize the embedded Intel 631xESB / 632xESB I/O
Controller Hub NICs (one channel per embedded NIC).
®
One LAN interface utilizes an optional external NIC known as the Intel RMM NIC. This
®
NIC requires the presence of the optional Intel Remote Management Module add-in
card.
See the IPMI 2.0 specification for details about the IPMI-over-LAN protocol.
4.29.1 IPMI 1.5 Messaging
The communication protocol packet format consists of IPMI requests and responses
encapsulated in an IPMI session wrapper for authentication, and wrapped in an RMCP packet,
which is wrapped in an IP/UDP packet. Although authentication is provided, no encryption is
provided, so administrating some settings, such as user passwords, through this interface is not
advised.
Session establishment commands are IPMI commands that do not require authentication or an
associated session.
The BMC supports None (no authentication), Straight Password / Key and MD5 authentication
types over the LAN interface.
150 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet System Management
4.29.2 IPMI 2.0 Messaging
IPMI 2.0 messaging is built over RMCP+ and has a different session establishment protocol.
The session commands are defined by RSSP and implemented at the RMCP+ level, not IPMI
commands. Authentication is implemented at the RMCP+ level. RMCP+ provides link payload
encryption, so it is possible to communicate private / sensitive data (confidentiality).
The BMC supports the following cipher suites:
Table 49. Supported RMCP+ Cipher Suites
ID Authentication Integrity Confidentiality
Algorithm Algorithm(s) Algorithm(s)
0 RAKP-none None None
1 RAKP-HMAC-SHA1 None None
2 RAKP-HMAC-SHA1 HMAC-SHA1-96 None
3 RAKP-HMAC-SHA1 HMAC-SHA1-96 AES-CBC-128
6 RAKP-HMAC-MD5 None None
7 RAKP-HMAC-MD5 HMAC-MD5-128 None
8 RAKP-HMAC-MD5 HMAC-MD5-128 AES-CBC-128
11 RAKP-HMAC-MD5 MD5-128 None
12 RAKP-HMAC-MD5 MD5-128 AES-CBC-128
For user authentication, the BMC can be configured with ‘null’ user names, whereby password /
key lookup is done based on ‘privilege level only’, or with non-null user names, where the key
lookup for the session is determined according to the user name.
IPMI 2.0 messaging introduces the concept of payload types and payload IDs. This allows data
types other than IPMI commands to be transferred. IPMI 2.0 Serial-over-LAN is implemented as
a payload type.
Table 50. Supported RMCP+ Payload Types
Payload Type Feature IANA
00h IPMI Message N/A
01h Serial-over-LAN N/A
02h OEM Explicit Intel (343)
10h – 15h Session Setup N/A
Revision 1.3 151
Intel order number D38960-006
System Management Intel® S5000 Server Board Family Datasheet
®
4.29.3 Intel 631xESB / 632xESB I/O Controller Hub Embedded LAN Channels
®
Even though the Intel 631xESB / 632xESB I/O Controller Hub embedded NICs are shared by
the BMC and the server, sharing means only that both the BMC and the server use the same
NIC. These shared NICs provide a dedicated MAC address solely for BMC use. As a result, in
some ways these channels are more similar to a dedicated LAN channel than a shared channel.
The IP address for the server is always different from the BMC IP address for a particular
embedded NIC.
For these channels, support can be enabled for IPMI-over-LAN, ARP, and DHCP.
As an integral part of the I/O Controller Hub, the BMC has a high degree of access to and
control over its primary network interfaces. Subsequent sections describe how the BMC
configures the I/O Controller Hub to enable these enhanced features.
All LAN features for a given LAN channel are disabled unless the channel’s access mode is set
to Always Enabled.
®
If an Intel RMM add-in card is installed, then the I/O Controller Hub embedded LAN channels
are configured differently than for a server that does not include this device. See section 4.21
for information.
4.29.4 Address Resolution Protocol Support
®
The BMC can receive and respond to ARP requests on Intel 631xESB / 632xESB I/O
Controller Hub NICs, and can also generate gratuitous ARPs.
The BMC’s default configuration on its first power on, or when the private store map changes or
is corrupted, is for all ARP generation to be disabled.
4.29.5 Internet Control Message Protocol Support
®
The BMC supports the following ICMP message types targeting the BMC over Intel 631xESB /
632xESB I/O Controller Hub NICs:
Echo request (ping) – The BMC sends an Echo Reply
Destination unreachable – If message is associated with an active socket connection
within the BMC, the BMC closes the socket
Redirect – The BMC updates its internal routing table
Timestamp Request – The BMC sends a Timestamp Reply
4.29.6 Serial-over-LAN (SOL) 2.0
The BMC supports the IPMI 2.0 defined SOL feature. Platforms that use the Intel® 5000 Series
Chipset do not support the previous generation Intel proprietary SOL, now known as SOL 1.0.
IPMI 2.0 introduces a standard serial-over-LAN feature, which is implemented as a standard
payload type (01h) over RMCP+.
152 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Error Reporting and Handling
5. Error Reporting and Handling
This chapter provides error message, error codes, and beep codes. For information about the
role of the BIOS in error handling and the interaction between the BIOS, platform hardware, and
server management firmware with regard to error handling see Chapter 4, System
Management.
5.1 Fault Resilient Booting (FRB)
Fault resilient booting (FRB) is feature that Intel provides to detect and handle errors during the
system boot process. FRB helps to make sure the system boots, even if one or more
processors fail during POST. There are several possible failures during the booting process that
can be detected and handled by the BIOS and BMC:
Boot-strap processor (BSP) POST failure (FRB2 watchdog timer)
Operating system load failures
Application processor (AP) failures
5.1.1 BSP POST Failures (FRB-2)
The FRB-2 process uses a watchdog timer that can be configured to reset the system if it hangs
during POST. The BIOS sets the FRB-2 timer to 6 minutes.
The BIOS disables the watchdog timer before prompting the user for a boot password / user
password, while scanning for option ROM, and when the user enters BIOS Setup. If the system
hangs during POST, before the BIOS disables the FRB-2 timer, the BMC generates an
asynchronous system reset (ASR).
The BMC retains status bits that can the BIOS can read later in POST to disable the previously
failing processor, to log the appropriate event into the system event log, and to display an
appropriate error message.
5.1.2 Operating System Load Failures (OS Boot Timer)
The BIOS provides an additional watchdog timer to provide fault resilient booting to the
operating system. This timer option is disabled by default. The timeout value and the option to
enable the timer are configured in BIOS Setup. When enabled, the BIOS enables the OS Boot
Timer in the BMC. It is the responsibility of the operating system or an application to disable this
timer once the operating system has successfully loaded.
Warning: Enabling this option without having an operating system or server management
application installed that supports this feature will cause the system to reboot when the timer
expires. Consult your application or operating system documentation to ensure this feature is
supported.
Revision 1.3 153
Intel order number D38960-006
Error Reporting and Handling Intel® S5000 Server Board Family Datasheet
5.2 Error Handling and Logging
This section defines how errors are handled by the system BIOS, including a discussion of the
role of the BIOS in error handling and the interaction between the BIOS, platform hardware, and
server management firmware with regard to error handling. In addition, error-logging techniques
are described and beep codes for errors are defined.
5.2.1 Error Sources and Types
Server management must correctly and consistently handle system errors. System errors that
can be enabled and disabled individually or as a group can be categorized as follows:
PCI bus
Memory single- and multi-bit errors
Sensors
Errors detected during POST and logged as POST errors
Sensors are managed by the BMC. The BMC is capable of receiving event messages from
individual sensors and logging system events.
5.2.2 Error Logging via SMI Handler
The SMI handler handles and logs system-level events that are not visible to server
management firmware. The SMI handler pre-processes all system errors, even those that are
normally considered to generate an NMI.
The SMI handler sends a command to the BMC to log the event and provides the data to be
logged. For example, the BIOS programs the hardware to generate an SMI on a single-bit
memory error and logs the location of the failed FBDIMM in the system event log. System
events that are handled by the BIOS generate SMIs. After the BIOS finishes logging the error it
will assert the NMI if needed.
5.2.2.1 PCI Bus Error
The PCI bus defines two error pins, PERR# and SERR#. These are used for reporting PCI
parity errors and system errors, respectively. The BIOS can be instructed to enable or disable
reporting PERR# and SERR# through NMI. Disabling NMI for PERR# and / or SERR# also
disables logging of the corresponding event.
In the case of PERR#, the PCI bus master has the option to retry the offending transaction, or to
report it using SERR#. All other PCI-related errors are reported by SERR#. All PCI-to-PCI
bridges are configured so that they generate SERR# on the primary interface whenever there is
SERR# on the secondary side, as long as SERR# is enabled in BIOS Setup. The same is true
for PERR#.
5.2.2.2 PCI Express* Errors
Fatal and critical PCI Express* errors are logged as PCI system errors and promoted to an NMI.
All non-critical PCI Express errors are logged as PCI parity errors.
154 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Error Reporting and Handling
5.2.2.3 Processor Bus Error
The BIOS enables the error correction and detection capabilities of the processors by setting
appropriate bits in the processor model specific register (MSR) and the appropriate bits in the
chipset.
In the case of unrecoverable errors on the host processor bus, proper execution of the SMI
handler cannot be guaranteed and the handler cannot be relied upon to log such conditions.
The handler records the error to the system event log only if the system has not experienced a
catastrophic failure that compromises the integrity of the handler.
5.2.2.4 Memory Bus Error
The hardware is programmed to generate an SMI on correctable data errors in the memory
array. The SMI handler records the error and the FBDIMM location to the system event log.
Uncorrectable errors in the memory array are mapped to SMI because the BMC cannot
determine the location of the faulty FBDIMM. The uncorrectable errors may have corrupted the
contents of SMRAM. The SMI handler will log the failing FBDIMM number to the BMC if the
SMRAM contents are still valid. The ability to isolate the failure down to a single FBDIMM may
not be available on certain errors, and / or during early POST.
5.2.2.5 OS Watchdog Failure
If an operating system device driver is using the watchdog timer to detect software or hardware
failures and that timer expires, an asynchronous reset (ASR) is generated. This is equivalent to
a hard reset. The POST portion of the BIOS can query the BMC for watchdog reset events as
the system reboots, and logs this event in the SEL.
5.2.2.6 Boot Event
The BIOS downloads the system date and time to the BMC during POST and logs a boot event.
Software that parses the event log should not treat the boot event as an error.
5.2.3 Timestamp Clock Event
The BMC maintains a 4-byte internal timestamp clock used by the SEL and SDR subsystems.
The timestamp clock is incremented once per second.
5.2.3.1 No Real-time Clock (RTC) Access
After a BMC reset, the BMC sets the initial value of the timestamp clock to 0x00000000, after
which it is incremented once per second. A SEL event containing a timestamp from 0x00000000
to 0x14000000 has a timestamp value that is relative to BMC initialization.
During POST, the BIOS tells the BMC the current RTC time. The BMC maintains that time using
a hardware signal driven from the same oscillator that maintains the system’s time-of-day clock.
If the user changes the RTC during operation, SMS is responsible for synchronizing the time
with the BMC.
Note: The BMC can lose the current timestamp during a BMC cold reset or a firmware update.
Revision 1.3 155
Intel order number D38960-006
Error Reporting and Handling Intel® S5000 Server Board Family Datasheet
5.3 Error Messages and Error Codes
The system BIOS displays error messages on the screen. Before video initialization, beep
codes inform the user of errors. POST error codes are logged in the event log. The BIOS
displays POST error codes on the screen.
5.3.1 Diagnostic LEDs
During the system boot process, the BIOS executes several platform configuration processes,
each of which is assigned a specific hex POST code number. As each configuration routine is
started, the BIOS will display the POST code on the POST code diagnostic LEDs on the back
edge of the server board. To assist in troubleshooting a system hang during the POST process,
the diagnostic LEDs can be used to identify the last POST process to be executed.
Each POST code is represented by a combination of colors from four LEDs. The LEDs are each
capable of displaying three colors: green, red, and amber. The POST codes are divided into an
upper nibble and a lower nibble. Each bit in the upper nibble is represented by a red LED and
each bit in the lower nibble is represented by a green LED. If both bits are set in the upper and
lower nibbles then both red and green LEDs are lit, resulting in an amber color. If both bits are
clear, then the LED is off.
In the below example, BIOS sends a value of ACh to the diagnostic LED decoder. The LEDs
are decoded as follows:
Red bits = 1010b = Ah
Green bits = 1100b = Ch
Since the red bits correspond to the upper nibble and the green bits correspond to the lower
nibble, the two are concatenated to be ACh.
Table 51. POST Progress Code LED Example
8h 4h 2h 1h
LEDs Red Green Red Green Red Green Red Green
ACh 1 1 0 1 1 0 0 0
Result Amber Green Red Off
MSB LSB
156 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Error Reporting and Handling
A. Status LED D. Bit 1 LED (POST LED)
B. ID LED E. Bit 2 LED (POST LED)
C. MSB LED (POST LED) F. LSB LED (POST LED)
Figure 29. Location of Diagnostic LEDs on Server Board
Note: See the server or workstation Technical Product Specification that applies to your product
for more detailed information on the location of the back panel diagnostic LEDs.
5.3.2 POST Code Checkpoints
Table 52. POST Code Checkpoints
Diagnostic LED Decoder Description
Checkpoint
G=Green, R=Red, A=Amber
MSB Bit 1 Bit 2 LSB
Host Processor
0x10h Off Off Off R Power-on initialization of the host processor (bootstrap processor)
0x11h Off Off Off A Host processor cache initialization (including AP)
0x12h Off Off G R Starting application processor initialization
0x13h Off Off G A SMM initialization
Chipset
0x21h Off Off R G Initializing a chipset component
Memory
0x22h Off Off A Off Reading configuration data from memory (SPD on FBDIMM)
0x23h Off Off A G Detecting presence of memory
0x24h Off G R Off Programming timing parameters in the memory controller
0x25h Off G R G Configuring memory parameters in the memory controller
0x26h Off G A Off Optimizing memory controller settings
0x27h Off G A G Initializing memory, such as ECC init
0x28h G Off R Off Testing memory
PCI Bus
0x50h Off R Off R Enumerating PCI busses
0x51h Off R Off A Allocating resources to PCI busses
0x52h Off R G R Hot Plug PCI controller initialization
Revision 1.3 157
Intel order number D38960-006
Error Reporting and Handling Intel® S5000 Server Board Family Datasheet
Diagnostic LED Decoder Description
Checkpoint G=Green, R=Red, A=Amber
MSB Bit 1 Bit 2 LSB
0x53h Off R G A Reserved for PCI bus
0x54h Off A Off R Reserved for PCI bus
0x55h Off A Off A Reserved for PCI bus
0x56h Off A G R Reserved for PCI bus
0x57h Off A G A Reserved for PCI bus
USB
0x58h G R Off R Resetting USB bus
0x59h G R Off A Reserved for USB devices
ATA / ATAPI / SATA
0x5Ah G R G R Resetting PATA / SATA bus and all devices
0x5Bh G R G A Reserved for ATA
SMBUS
0x5Ch G A Off R Resetting SMBUS
0x5Dh G A Off A Reserved for SMBUS
Local Console
0x70h Off R R R Resetting the video controller (VGA)
0x71h Off R R A Disabling the video controller (VGA)
0x72h Off R A R Enabling the video controller (VGA)
Remote Console
0x78h G R R R Resetting the console controller
0x79h G R R A Disabling the console controller
0x7Ah G R A R Enabling the console controller
Keyboard (PS2 or USB)
0x90h R Off Off R Resetting the keyboard
0x91h R Off Off A Disabling the keyboard
0x92h R Off G R Detecting the presence of the keyboard
0x93h R Off G A Enabling the keyboard
0x94h R G Off R Clearing keyboard input buffer
0x95h R G Off A Instructing keyboard controller to run Self Test (PS2 only)
Mouse (PS2 or USB)
0x98h A Off Off R Resetting the mouse
0x99h A Off Off A Detecting the mouse
0x9Ah A Off G R Detecting the presence of mouse
0x9Bh A Off G A Enabling the mouse
Fixed Media
0xB0h R Off R R Resetting fixed media device
0xB1h R Off R A Disabling fixed media device
0xB2h R Off A R Detecting presence of a fixed media device (IDE hard drive detection,
etc.)
0xB3h R Off A A Enabling / configuring a fixed media device
Removable Media
0xB8h A Off R R Resetting removable media device
0xB9h A Off R A Disabling removable media device
158 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Error Reporting and Handling
Diagnostic LED Decoder Description
Checkpoint G=Green, R=Red, A=Amber
MSB Bit 1 Bit 2 LSB
0xBAh A Off A R Detecting presence of a removable media device (IDE CDROM
detection, etc.)
0xBCh A G R R Enabling / configuring a removable media device
Boot Device Selection
0xD0 R R Off R Trying boot device selection
0xD1 R R Off A Trying boot device selection
0xD2 R R G R Trying boot device selection
0xD3 R R G A Trying boot device selection
0xD4 R A Off R Trying boot device selection
0xD5 R A Off A Trying boot device selection
0xD6 R A G R Trying boot device selection
0xD7 R A G A Trying boot device selection
0xD8 A R Off R Trying boot device selection
0xD9 A R Off A Trying boot device selection
0XDA A R G R Trying boot device selection
0xDB A R G A Trying boot device selection
0xDC A A Off R Trying boot device selection
0xDE A A G R Trying boot device selection
0xDF A A G A Trying boot device selection
Pre-EFI Initialization (PEI) Core
0xE0h R R R Off Started dispatching early initialization modules (PEIM)
0xE2h R R A Off Initial memory found, configured, and installed correctly
0xE1h R R R G Reserved for initialization module use (PEIM)
0xE3h R R A G Reserved for initialization module use (PEIM)
Driver eXecution Enviornment (DXE) Core
0xE4h R A R Off Entered EFI driver execution phase (DXE)
0xE5h R A R G Started dispatching drivers
0xE6h R A A Off Started connecting drivers
DXE Drivers
0xE7h R A A G Waiting for user input
0xE8h A R R Off Checking password
0xE9h A R R G Entering BIOS setup
0xEAh A R A Off Flash Update
0xEEh A A A Off Calling Int 19. One beep unless silent boot is enabled.
0xEFh A A A G Unrecoverable boot failure / S3 resume failure
Runtime Phase / EFI Operating System Boot
0xF4h R A R R Entering Sleep state
0xF5h R A R A Exiting Sleep state
0xF8h A R R R Operating system has requested EFI to close boot services
(ExitBootServices ( ) has been called)
0xF9h A R R A Operating system has switched to virtual address mode
(SetVirtualAddressMap ( ) has been called)
0xFAh A R A R Operating system has requested the system to reset (ResetSystem ()
has been called)
Revision 1.3 159
Intel order number D38960-006
Error Reporting and Handling Intel® S5000 Server Board Family Datasheet
Diagnostic LED Decoder Description
Checkpoint G=Green, R=Red, A=Amber
MSB Bit 1 Bit 2 LSB
Pre-EFI Initialization Module (PEIM) / Recovery
0x30h Off Off R R Crisis recovery has been initiated because of a user request
0x31h Off Off R A Crisis recovery has been initiated by software (corrupt flash)
0x34h Off G R R Loading crisis recovery capsule
0x35h Off G R A Handing off control to the crisis recovery capsule
0x3Fh G G A A Unable to complete crisis recovery.
5.3.3 POST Error Messages and Handling
Whenever possible, the BIOS will output the current boot progress codes on the video screen.
Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class,
subclass, and operation information. The class and subclass fields point to the type of hardware
that is being initialized. The operation field represents the specific initialization activity. Based on
the data bit availability to display progress codes, a progress code can be customized to fit the
data width. The higher the data bit, the higher the granularity of information that can be sent on
the progress port. The progress codes may be reported by the system BIOS or option ROMs.
The Response section in the following table is divided into two types:
Pause: The message is displayed in the Error Manager screen, an error is logged to the
SEL, and user input is required to continue. The user can take immediate corrective
action or choose to continue booting.
Halt: The message is displayed in the Error Manager screen, an error is logged to the
SEL, and the system cannot boot unless the error is resolved. The user needs to replace
the faulty part and restart the system.
Table 53. POST Error Messages and Handling
Error Code Error Message Response
004C Keyboard / interface error Pause
0012 CMOS date / time not set Pause
5220 Configuration cleared by jumper Pause
5221 Passwords cleared by jumper Pause
5223 Configuration default loaded Pause
0048 Password check failed Halt
0141 PCI resource conflict Pause
0146 Insufficient memory to shadow PCI ROM Pause
8110 Processor 01 internal error (IERR) on last boot Pause
8111 Processor 02 internal error (IERR) on last boot Pause
8120 Processor 01 thermal trip error on last boot Pause
8121 Processor 02 thermal trip error on last boot Pause
8130 Processor 01 disabled Pause
8131 Processor 02 disabled Pause
8160 Processor 01 unable to apply BIOS update Pause
160 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Error Reporting and Handling
Error Code Error Message Response
8161 Processor 02 unable to apply BIOS update Pause
8190 Watchdog timer failed on last boot Pause
8198 Operating system boot watchdog timer expired on last boot Pause
0192 L3 cache size mismatch Halt
0194 CPUID, processor family are different Halt
0195 Front side bus mismatch Pause
0197 Processor speeds mismatched Pause
8300 Baseboard management controller failed self-test Pause
8306 Front panel controller locked Pause
8305 Hotswap controller failed Pause
84F2 Baseboard management controller failed to respond Pause
84F3 Baseboard management controller in update mode Pause
84F4 Sensor data record empty Pause
84FF System event log full Pause
8500 Memory Component could not be configured in the selected RAS mode. Pause
8520 DIMM_A1 failed Self Test (BIST). Pause
8521 DIMM_A2 failed Self Test (BIST). Pause
8522 DIMM_A3 failed Self Test (BIST). Pause
8523 DIMM_A4 failed Self Test (BIST). Pause
8524 DIMM_B1 failed Self Test (BIST). Pause
8525 DIMM_B2 failed Self Test (BIST). Pause
8526 DIMM_B3 failed Self Test (BIST). Pause
8527 DIMM_B4 failed Self Test (BIST). Pause
8528 DIMM_C1 failed Self Test (BIST). Pause
8529 DIMM_C2 failed Self Test (BIST). Pause
852A DIMM_C3 failed Self Test (BIST). Pause
852B DIMM_C4 failed Self Test (BIST). Pause
852C DIMM_D1 failed Self Test (BIST). Pause
852D DIMM_D2 failed Self Test (BIST). Pause
852E DIMM_D3 failed Self Test (BIST). Pause
852F DIMM_D4 failed Self Test (BIST). Pause
8540 Memory Component lost redundancy during the last boot. Pause
8580 DIMM_A1 Correctable ECC error encountered. Pause
8581 DIMM_A2 Correctable ECC error encountered. Pause
8582 DIMM_A3 Correctable ECC error encountered. Pause
8583 DIMM_A4 Correctable ECC error encountered. Pause
8584 DIMM_B1 Correctable ECC error encountered. Pause
8585 DIMM_B2 Correctable ECC error encountered. Pause
8586 DIMM_B3 Correctable ECC error encountered. Pause
8587 DIMM_B4 Correctable ECC error encountered. Pause
8588 DIMM_C1 Correctable ECC error encountered. Pause
8589 DIMM_C2 Correctable ECC error encountered. Pause
858A DIMM_C3 Correctable ECC error encountered. Pause
858B DIMM_C4 Correctable ECC error encountered. Pause
Revision 1.3 161
Intel order number D38960-006
Error Reporting and Handling Intel® S5000 Server Board Family Datasheet
Error Code Error Message Response
858C DIMM_D1 Correctable ECC error encountered. Pause
858D DIMM_D2 Correctable ECC error encountered. Pause
858E DIMM_D3 Correctable ECC error encountered. Pause
858F DIMM_D4 Correctable ECC error encountered. Pause
8600 Primary and secondary BIOS IDs do not match. Pause
Override jumper is set to force boot from lower alternate BIOS bank of flash Pause
8601
ROM
8602 WatchDog timer expired (secondary BIOS may be bad!) Pause
8603 Secondary BIOS checksum fail Pause
5.3.4 POST Error Beep Codes
The following table lists POST error beep codes. Prior to system Video initialization, BIOS uses
these beep codes to inform users on error conditions. The beep code is followed by a user
visible code on the diagnostic LEDs.
Table 54. POST Error Beep Codes
Beeps Error Message POST Progress Code Description
3 Memory error System halted because a fatal error related to the memory
was detected.
6 BIOS rolling back The system has detected a corrupted BIOS in the flash
error part, and is rolling back to the last good BIOS.
5.3.5 POST Error Pause Option
For POST error(s) that are listed as Pause, the BIOS enters the error manager and waits for the
user to press an appropriate key before booting the operating system or entering BIOS Setup.
The user can override this option by setting POST Error Pause to disabled in the BIOS Setup
utility Main menu page. If POST Error Pause is set to disabled, the system will boot the
operating system without user-intervention. The default value is set to enabled.
162 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Glossary
Glossary
This appendix contains important terms used in the preceding chapters. For ease of use,
numeric entries are listed first (e.g., “82460GX”) with alpha entries following (e.g., “ACPI”).
Acronyms are then entered in their respective place, with non-acronyms following.
Term Definition
ACPI Advanced Configuration and Power Interface
ADC Analog to Digital Converter.
AP Application Processor
API Application Programming Interface.
APIC Advanced Programmable Interrupt Control
ASIC Application Specific Integrated Circuit
ASMI Advanced Server Management Interface
ASR Asynchronous Reset
BIOS Basic Input/Output System
BIST Built-In Self Test
BMC Baseboard Management Controller
Bridge Circuitry connecting one computer bus to another, allowing an agent on one to access the other
BSP Bootstrap Processor
byte 8-bit quantity.
CBC Chassis Bridge Controller (A microcontroller connected to one or more other CBCs, together they
bridge the IPMB buses of multiple chassis.
CEK Common Enabling Kit
CHAP Challenge Handshake Authentication Protocol
CMOS In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes
of memory, which normally resides on the server board.
DPC Direct Platform Control
EEPROM Electrically Erasable Programmable Read-Only Memory
EHCI Enhanced Host Controller Interface
EMP Emergency Management Port
EPS External Product Specification
ESB2 Enterprise South Bridge 2
FBD Fully Buffered DIMM
FMB Flexible Mother Board
FRB Fault Resilient Booting
FRU Field Replaceable Unit
GB 1024MB
GPIO General Purpose I/O
GTL Gunning Transceiver Logic
HSC Hot-Swap Controller
Hz Hertz (1 cycle/second)
I2C Inter-Integrated Circuit Bus
®
IA Intel Architecture
IBF Input Buffer
ICH I/O Controller Hub
Revision 1.3 163
Intel order number D38960-006
Glossary Intel® S5000 Server Board Family Datasheet
Term Definition
ICMB Intelligent Chassis Management Bus
IERR Internal Error
IFB I/O and Firmware Bridge
INTR Interrupt
IP Internet Protocol
IPMB Intelligent Platform Management Bus
IPMI Intelligent Platform Management Interface
IR Infrared
ITP In-Target Probe
KB 1024 bytes
KCS Keyboard Controller Style
LAN Local Area Network
LCD Liquid Crystal Display
LED Light Emitting Diode
LPC Low Pin Count
LUN Logical Unit Number
MAC Media Access Control
MB 1024KB
MCH Memory Controller Hub
MD2 Message Digest 2 – Hashing Algorithm
MD5 Message Digest 5 – Hashing Algorithm – Higher Security
ms milliseconds
MTTR Memory Type Range Register
Mux Multiplexor
NIC Network Interface Controller
NMI Nonmaskable Interrupt
OBF Output Buffer
OEM Original Equipment Manufacturer
Ohm Unit of electrical resistance
PEF Platform Event Filtering
PEP Platform Event Paging
PIA Platform Information Area (This feature configures the firmware for the platform hardware)
PLD Programmable Logic Device
PMI Platform Management Interrupt
POST Power-On Self Test
PSMI Power Supply Management Interface
PWM Pulse-Width Modulation
RAM Random Access Memory
RASUM Reliability, Availability, Serviceability, Usability, and Manageability
RISC Reduced Instruction Set Computing
ROM Read Only Memory
RTC Real-Time Clock (Component of ICH peripheral chip on the server board)
SCI System Control Interrupt
SDR Sensor Data Record
164 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Glossary
Term Definition
5000 The chipset used in the server board.
SECC Single Edge Connector Cartridge
SEEPROM Serial Electrically Erasable Programmable Read-Only Memory
SEL System Event Log
SIO Server Input/Output
SMI Server Management Interrupt (SMI is the highest priority nonmaskable interrupt)
SMM Server Management Mode
SMS Server Management Software
SNMP Simple Network Management Protocol
TBD To Be Determined
TIM Thermal Interface Material
UART Universal Asynchronous Receiver/Transmitter
UDP User Datagram Protocol
UHCI Universal Host Controller Interface
UTC Universal time coordinare
VID Voltage Identification
VRD Voltage Regulator Down
Word 16-bit quantity
ZIF Zero Insertion Force
Revision 1.3 165
Intel order number D38960-006
Reference Documents Intel® S5000 Server Board Family Datasheet
Reference Documents
See the following documents for additional information:
Advanced Configuration and Power Interface Specification, Revision 1.0b. 1996, 1997,
1998. Intel Corporation, Microsoft Corporation, Toshiba Corporation.
Design for Test R18. BIOS/Firmware. Intel Corporation.
2
I C Address Allocation, Revision 1.13. 1997. Intel Corporation.
Intelligent Platform Management Interface Specification, Version 1.5. 2000. Intel
Corporation, Hewlett-Packard Company, NEC Corporation, Dell Computer Corporation.
Platform Management FRU Information Storage Definition, Version 1.0. 1998. Intel
Corporation, Hewlett-Packard Company, NEC Corporation, Dell Computer Corporation.
http://developer.intel.com/design/servers/ipmi/spec.htm
Server Power Control White Paper, Revision 0.93. November 5, 1998. Intel Corporation.
The SMBus Specification, Intel Corporation
Processor
Application Note AP-485 Intel Processor Identification and the CPUID Function.
http://www.intel.com/design/xeon/applnots/241618.htm
Standards
Advanced Configuration and Power Interface Specification, Revision 1.0b, February
1999, http://www.acpi.info/
El Torito CD-ROM Boot Specification, Version 1.0.,
http://www.phoenix.com/NR/rdonlyres/98D3219C-9CC9-4DF5-B496-
A286D893E36A/0/specscdrom.pdf
Extensible Firmware Interface Reference Specification, Version 1.0.,
http://www.intel.com/technology/efi/index.htm
Extensible Firmware Interface Reference Specification, Version 1.1,
http://www.intel.com/technology/efi/index.htm
Intelligent Platform Management Interface Specification, Version 1.5,
http://developer.intel.com/design/servers/ipmi/spec.htm
Intelligent Platform Management Interface Specification, Version 2.0,
http://developer.intel.com/design/servers/ipmi/spec.htm
Microsoft Headless Design Guidelines.
http://www.microsoft.com/whdc/system/platform/64bit/64bitsystems.mspx
Network PC System Design Guidelines, Revision 1.0,
http://www.intel.com/ managedpc/standard
PC99 System Design Guide, http://www.pcdesguide.com/
PCI Local Bus Specification, Revision 2.2, http://www.pcisig.org/
PCI to PCI Bridge Specification, Revision 1.1, http://www.pcisig.org/
PCI BIOS Specification, Revision 2.1, http://www.pcisig.org/
166 Revision 1.3
Intel order number D38960-006
Intel® S5000 Server Board Family Datasheet Reference Documents
PCI Power Management Specification, Revision 1.0, http://www.pcisig.org/
PCI IRQ Routing Table Specification, Revision 1.0, Microsoft Corporation.
POST Memory Manager Specification, Revision 1.01,
http://www.phoenix.com/NR/rdonlyres/873A00CF-33AC-4775-B77E-
08E7B9754993/0/specspmm101.pdf
Plug and Play BIOS Specification, Revision 1.0a,
http://www.microsoft.com/whdc/system/pnppwr/pnp/default.mspx
System Management BIOS Reference Specification, Version 2.4,
http://www.dmtf.org/standards/published_documents/DSP0134.pdf
Extensible Firmware Interface Specification 1.10
http://www.intel.com/technology/efi/main_specification.htm
Universal Serial Bus Revision 1.1 Specification,
http://www.intel.com/technology/usb/spec.htm
Wired For Management Baseline Specification, Revision 2.0,
http://www.intel.com/design/archives/wfm/downloads/base20.htm
Revision 1.3 167
Intel order number D38960-006
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods