Elite.Parts chervon right Manufacturers chervon right I chervon right INTEGRATED POWER DESIGNS chervon right REL-70-4010
About product Features Datasheet FAQ

INTEGRATED POWER DESIGNS REL-70-4010

Image of INTEGRATED POWER DESIGNS REL-70-4010

Description

Integrated Power Designs REL-70-4010 Power Supply. Open Frame | 70W | Quad Output | Compact 2.5?x4.5?x1.2?

Part Number

REL-70-4010

Price

Request Quote

Manufacturer

INTEGRATED POWER DESIGNS

Lead Time

Request Quote

Category

PRODUCTS - R

Features

Datasheet

pdf file

Integrated Power Designs-REL-70-4010-datasheet1-1948196857.pdf

94 KiB

Extracted Text

Quad Output AC/DC Medical Power Supply, 70W IPD REL-70 Series REL-70 SERIES AC-DC OUTPUT SPECIFICATIONS Total Output Power at 50°C 50W Convection Cooled FEATURES: 70W Forced Air Cooled • RoHS Compliant • EN 60950-1 ITE Certification Output Voltage Centering Output 1: (All outputs ± 0.5% • Universal 85-264 VAC Input • EN 60601-1 Medical Certification Output 2,3,4: at 50% load) ± 5.0% • High Efficiency • Class B Emissions per EN 55011/22 Output Voltage Adjust Range Output 1: 95 - 105% • Advanced SMT Design • Harmonic Current per EN 61000-3-2 Load Regulation Output 1: 0.5% (10-100% • Compact 2.5 x 4.5" x 1.2" Size • EMC to EN 61000-6-2 & EN 60601-1-2 Output 2: 5.0% load change) • 2 Year Warranty • Optional Chassis and Cover (4001-5) 8.0% • Fits 1U Applications • One to Four Outputs (2001) 8.0% Output 3: 5.0% Output 4: 5.0% Source Regulation Outputs 1 – 4: 0.5% Cross Regulation Outputs 2 – 4: 5.0% Output Noise Outputs 1 – 4: 1.0% Turn on Overshoot None Transient Response Outputs 1 – 4 Voltage Deviation 5.0% Recovery Time 500µS Load Change 50% to 100% Output Overvoltage Protection Output 1: 110% to 150% OPEN FRAME CHASSIS/COVER Output Overpower Protection 110-160% rated Pout, cycle on/off, auto recovery Hold Up Time 16 mS min., Full Power, 85V Input SAFETY SPECIFICATIONS Start Up Time 4 Seconds, 120V Input Protection Class: I INPUT SPECIFICATIONS General Overvoltage Category: II Source Voltage 85 – 264 Volts AC Pollution Degree: 2 Frequency Range 47 – 63 Hz nd Underwriters UL 60950-1 2 Edition Peak Inrush Current 40A st Laboratories UL 60601-1 1 Edition Efficiency 78% Typ., Full Power, 230V, varies by model File E137708/E140259 Power Factor 0.95 (Full Power, 230V) CB Certificate per IEC 60950-1:2005 ENVIRONMENTAL SPECIFICATIONS nd 2 Edition +A1:2009 including all Ambient Operating 0 C to + 70 C National Deviations Temperature Range Derating: See Power Rating Chart CB Certificate per IEC 60601-1 (1988) Ambient Storage Temp. Range - 40 C to + 85 C nd 2 Edition A1, A2 Temperature Coefficient Outputs 1 – 4: 0.02%/ C CAN/CSA-C22.2 No. 60950-1-07, UL Recognition GENERAL SPECIFICATIONS nd 2 Edition Mark for Canada Dielectric Strength(13) CAN/CSA-C22.2 No. 601-1-M90 File E137708/E140259 Reinforced Insulation 5656 VDC, Primary to Secondary, 1 Sec. with updates 1 and 2 Basic Insulation 2121 VDC, Primary to Ground, 1 Sec. EN 60950-1/A1:2010 Operational Insulation 500 VDC, Secondary to Ground, 1 Sec. TUV EN 60601-1/A2:1995 Leakage Current <300uA Earth Leakage Current Power Fail Signal Logic low with input power failure 10 mS Low Voltage Directive minimum prior to Output 1 dropping 1% Remote Sense (singles only) 250mV compensation of output cable losses Mean-Time Between Failures 100,000 Hours min., MIL-HDBK-217F, 25° C, GB MODEL LISTING Weight 0.60 Lbs. Open Frame MODEL NO. OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 1.00 Lbs. Chassis and Cover REL-70-4001 +3.3V/6A +5V/5A +12V/2A(7) -12V/2A(7) ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS REL-70-4002 +5V/6A +3.3V/5A +12V/2A(7) -12V/2A(7) Electrostatic Discharge EN 61000-4-2 +/-8kV Contact Discharge REL-70-4003 +5V/6A +3.3V/5A +15V/2A(7) -15V/2A(7) +/-8kV Air Discharge REL-70-4004 +5V/6A -5V/5A +12V/2A(7) -12V/2A(7) Radiated Electromagnetic Field EN 61000-4-3 80MHz-2.5GHz, 10/m, 80% AM REL-70-4005 +5V/6A -5V/5A +15V/2A(7) -15V/2A(7) EFT/Bursts EN 61000-4-4 +/-2 kV REL-70-4006 +5V/6A +24V/2A +12V/2A(7) -12V/2A(7) REL-70-4007 +5V/6A +24V/2A +15V/2A(7) -15V/2A(7) Surges EN 61000-4-5 +/- 1 kV Common Mode REL-70-4009 6.7V/5A 5V/4A +15V/2A(7) -15V/2A(7) +/- 2 kV Differential Mode REL-70-3001 +5V/6A +12V/2A -12V/2A(7) Conducted Immunity EN 61000-4-6 .15 to 80MHz, 10V, 80% AM REL-70-3002 +5V/6A +15V/2A -15V/2A(7) Voltage Dips and Interruptions EN 61000-4-11 30% Reduction, 500ms REL-70-3003 +5.1V/6A +7.5V/2A -7.5V/2A(7) 95% Reduction, 10ms REL-70-3004 +3.3V/6A +7V/5A +12V/2A(7) 60% Reduction, 1s (Criteria B) REL-70-2001 +3.3V/6A +5V/5A 95% Reductions, 5000ms REL-70-2002 +5V/6A +12V/4A Voltage Interruptions EN 61000-4-11 95% Reduction, 5s REL-70-2003 +5V/6A +24V/2A Radiated Emissions EN 55011/22 Class B REL-70-2004 +12V/3A -12V/3A Conducted Emissions EN 55011/22 Class B REL-70-2005 +15V/3A -15V/2A Harmonic Current Emissions EN 61000-3-2 REL-70-2006 +5.5V/6A -5.5V/5A Voltage Fluctuations and Flicker EN 61000-3-3 REL-70-1001 2.5V/14A(1) NOTES REL-70-1002 3.3V/14A(1) Consult factory for alternate output configurations. REL-70-1003 5V/14A(1) Consult factory for positive, negative or floating outputs. REL-70-1004 12V/5.8A Refer to Applications Information for complete output power ratings. REL-70-1005 15V/4.7A All specifications are maximum at 25 C, 110W unless otherwise stated, may vary by REL-70-1006 24V/2.9A model and are subject to change without notice. REL-70-1007 28V/2.5A Specify optional chassis and cover when ordering. REL-70-1008 48V/1.5A www.trcelectronics.com/ipd TRC ELECTRONICS, INC. 1.888.612.9514 Quad Output AC/DC Medical Power Supply, 70W IPD REL-70 Series REL-70 MECHANICAL SPECIFICATIONS APPLICATIONS INFORMATION 1. Rated 10A with convection cooling. OPEN FRAME 2. Total power must not exceed 50 watts with convection cooling on open frame .65 (16.5) 3.20 (81.3) 4−40 models. MTG HOLE 3. Total power must not exceed 70 watts with 300LFM forced air cooling on open (2 PLACES) frame models. .80 (20.3) 4. Total power must not exceed 40 watts with convection cooling and chassis/cover 1.00 (25.4) 1.22 (31.0) option. MAX 5. Total power must not exceed 70 watts with 300LFM forced air cooling and chassis/cover option. P3 6. Each output can deliver its rated current but total output power must not exceed 1 (+) OUTPUT 1 maximum power as determined by the cooling method stated above. 2 (+) SENSE 3 (−) OUTPUT 1 7. Rated 1.5 A with convection cooling. 4 (−) SENSE 5 (−) P.F. RTN 8. Sufficient area must be provided around convection cooled power supplies to 6(+) P.F. SIG 3 P3 2 6 P2 allow natural movement of air to develop. 1 5 1 (−) OUTPUT 1 1 9. 300 linear feet per minute of airflow must be maintained one inch above any point 2 (−) OUTPUT 1 3 (−) OUTPUT 1 of the heatsink in the direction shown when forced air cooling is required. 4 (−) OUTPUT 1 3 5 (+) OUTPUT 1 2 10. This product is intended for use as a professionally installed component within 6 (+) OUTPUT 1 AC P1 7 (+) OUTPUT 1 INPUT information technology and medical equipment. N 8(+) OUTPUT 1 P2 11. A minimum load of 10% is required on output one to ensure proper regulation of V1 ADJUST GND remaining outputs. 1 12. Remote sense terminals may be used to compensate for cable losses up to SINGLE OUTPUT MODEL .128 DIA 250mV (single output models only). The use of a twisted pair is recommended as MTG HOLE (4 PLACES) well as a de-coupling capacitor (0.1 - 10µF) and a capacitor of 100µF/amp connected across the load side. 13. Peak to peak output ripple and noise is measured directly at the output terminals 4.50 (114.3) .15 (3.8) TYP 4.20 (106.7) of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth. P2 1 (−) OUTPUT 4 14. This product was type tested and safety certified using the dielectric strength test 1 2 (+) OUTPUT 4 voltages listed in Table V of UL 60601-1. In consideration of Clause 20.4g, care 3 (−) OUTPUT 3 2.20 (55.9) 4 (+) OUTPUT 3 must be taken to insure that the voltage applied to a reinforced insulation does P2 5 (−) OUTPUT 2 6 (+) OUTPUT 2 not overstress basic insualtion. Secondary to ground capacitors may need to be 7 (−) OUTPUT 1 L AC 8(+) OUTPUT 1 removed prior to performing a dielectric strength type test on the end product. It is P1 2.50 (63.5) INPUT N V1 ADJUST highly recommended that the DC test voltages litsed in DVB.1, Annex DVB are 1 P3 P3 GND not exceeded during a production-line dielectric strength test of the assembled 1 (−) P.F. RTN 2(+) P.F. SIG end product. Please consult factory for further information. MULTIPLE OUTPUT MODEL 15. This power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing an AC dielectric .65 (16.5) 3.20 (81.3) 4−40 MTG HOLE strength test. (2 PLACES) 16. Maximum screw penetration into bottom chassis mounting holes is .100 inches. 17. Maximum screw penetration into side chassis mounting holes is .250 inches. 1.22 (31.0) 1.00 (25.4) MAX .80 (20.3) 18. To meet emissions specifications, all four mounting hole pads must be electrically connected to a common metal chassis. Chassis/cover option recommended. 19. This product includes only one fuse in the input circuit. In consideration of Clause 57.6 of UL 60601-1, a second fuse may be required in the end product. OPTIONAL CHASSIS/COVER MAXIMUM Output Power vs. Ambient Temperature 70 .25 (6.4) TYP 4.20 (106.7) F O RCE D AIR CO O L ING 60 50 4−40 .68 (17.3) C ON V E C T ION C OOL IN G MTG HOLE 40 (2 PLACES) 30 1.48 (37.6) 20 10 0 4.79 (121.6) 0 102030 40506070 .30 (7.6) 4.20 (106.7) A m b ie n t T e m p eratu re ( C ) Connector Specifications .23 (5.8) P1 AC Input .156 friction lock header mates with Tyco 640250-3 or 3 1 equivalent crimp terminal housing with Tyco 3-640706-1 or 2.20 (55.9) equivalent crimp terminal. P2 P2 DC Output .156 friction lock header mates with Tyco 770849-8 or 2 3 (Single) equivalent crimp terminal housing with Tyco 3-640707-1 or L P1 equivalent crimp terminal. 2.62 (66.5) N V1 P2 DC Output .156 friction lock header mates with Tyco 770849-8 or 1 4−40 P3 MTG HOLE (4 PLACES−BASE) (Multiple) equivalent crimp terminal housing with Tyco 3-640707-1 or 1 equivalent crimp terminal. ALL DIMENSIONS IN INCHES (MM) G Ground .187 quick disconnect terminal. P3 P.F./Sense .100 breakaway header mates with Molex 22-55-2061 or Recommended Air Flow Direction (Single) equivalent crimp terminal housing with Molex type 71851 or equivalent crimp terminal. 1 – Optimum 2 – Good 3 – Fair P3 Power Fail .100 breakaway header mates with Molex 50-57-9002 or (Multiple) equivalent crimp terminal housing with Molex type 71851 or equivalent crimp terminal. www.trcelectronics.com/ipd TRC ELECTRONICS, INC. 1.888.612.9514

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the REL-70-4010 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Integrated Power Designs REL-110 Series - AC/DC 100W Power Supplies

product

Integrated Power Designs REL-110-1001 100W AC/DC Power Supply, 2.5V/22A

product

Integrated Power Designs REL-110-1002 100W AC/DC Power Supply, 3.3V/22A

product

Integrated Power Designs REL-110-1003 100W AC/DC Power Supply, 5V/22A

product

Integrated Power Designs REL-110-1004 100W AC/DC Power Supply, 12V/9.2A

product

Integrated Power Designs REL-110-1005 100W AC/DC Power Supply, 15V/7.3A