INTEGRATED POWER DESIGNS REL-110-1003
Specifications
Ambient Storage Temp. Range
- 40° C to + 85° C
Cross Regulation Outputs 2–4
5.0%
Efficiency
82% Typ., Full Power, 230V, varies by model
Frequency Range
47 – 63 Hz
Hold Up Time
16 mS min., Full Power, 85V Input
Load Change
50% to 100%
Load Regulation (2011 Model)
6.0%
Load Regulation (4001-5 Models)
8.0%
Load Regulation Output 1
0.5%
Load Regulation Output 2
5.0%
Load Regulation Output 3
5.0%
Load Regulation Output 4
5.0%
Output Noise Outputs 1–4
1.0%
Output Over voltage Protection Output 1
110% to 150%
Output Overpower Protection
110-160% rated Pout, cycle on/off, auto recovery
Output Voltage Adjust Range
95-105%
Output Voltage Centering Output1
± 0.5%(All outputs at 50% load)
Output Voltage Centering Output2
± 5.0%
Output Voltage Centering Output3
± 5.0%
Output Voltage Centering Output4
± 5.0%
Peak Inrush Current
40A
Power Factor
0.95 (Full Power, 230V)
Recovery Time
500µS
Source Regulation Outputs 1–4
0.5%
Source Voltage
85 – 264 Volts AC
Start Up Time
4 Seconds, 120V Input
Temperature Coefficient
Outputs 1 – 4:0.02%/°C
Temperature Rating
0° C TO + 70° C Derating: See Power Rating Chart
Total Output Power at 50°C
110W 300 LFM Forced Air
Transient Response
Outputs 1–4
Turn on Overshoot
None
Voltage Deviation
5.0%
Features
- Advanced SMT Design
- Class B Emissions per EN 55011/22
- Compact 3" x 5" x 1.3" Size
- EMC to EN 61000-6-2 & EN 60601-1-2
- EN 60601-1 Medical Certification
- EN 60950-1 ITE Certification
- Fits 1U Applications
- Harmonic Current per EN 61000-3-2
- High Efficiency
- One to Four Outputs
- Optional Chassis and Cover
- RoHS Compliant
- Universal 85-264 VAC Input
Datasheet
Extracted Text
110 WATTS REL-110 SERIES AC-DC OUTPUT SPECIFICATIONS Total Output Power at 50°C 80W Convection Cooled FEATURES: 110W 300 LFM Forced Air • RoHS Compliant • EN 60950-1 ITE Certification Output Voltage Centering Output 1: ± 0.5% (All outputs • Universal 85-264 VAC Input • EN 60601-1 Medical Certification Output 2: ± 5.0% at 50% load) • High Efficiency • Class B Emissions per EN 55011/22 Output 3: ± 5.0% • Advanced SMT Design • Harmonic Current per EN 61000-3-2 Output 4: ± 5.0% • Compact 3" x 5" x 1.3" Size • EMC to EN 61000-6-2 & EN 60601-1-2 Output Voltage Adjust Range Output 1: 95-105% • Fits 1U Applicat ions • Optional Chassis and Cover Load Regulation Output 1: 0.5% (10-100% load change) • One to Four Outputs Output 2: 5.0% (4001-5 Models) 8.0% (2001 Model) 6.0% Output 3: 5.0% Output 4: 5.0% Source Regulation Outputs 1 – 4: 0.5% Cross Regulation Outputs 2 – 4: 5.0% Output Noise Outputs 1 – 4: 1.0% Turn on Overshoot None Transient Response Outputs 1 – 4 Voltage Deviation 5.0% Recovery Time 500µS Load Change 50% to 100% Output Overvoltage Protection Output 1: 110% to 150% OPEN FRAME CHASSIS/COVER Output Overpower Protection 110-160% rated Pout, cycle on/off, auto recovery Hold Up Time 16 mS min., Full Power, 85V Input SAFETY SPECIFICATIONS Start Up Time 4 Seconds, 120V Input INPUT SPECIFICATIONS Protection Class: I Source Voltage 85 – 264 Volts AC General Overvoltage Category: II Frequency Range 47 – 63 Hz Pollution Degree: 2 Peak Inrush Current 40A nd Underwriters UL 60950-1 2 Edition, 2007 Efficiency 82% Typ., Full Power, 230V, varies by model st Laboratories U L 60 601-1 1 Edition, 2006 Power Factor 0.95 (Full Power, 230V) File E137708/E140259 AAMI/ANSI ES 60601-1, 2005 ENVIRONMENTAL SPECIFICATIONS CB Reports/Certificates (including all AMBIENT OPERATING 0° C TO + 70° C National and Group Deviations) Temperature Range Derating: See Power Rating Chart IEC 60950-1/A1:2009, Second Edition Ambient Storage Temp. Range - 40° C to + 85° C IEC 60601-1:1988 +A1:1991 +A2:1995 Temperature Coefficient Outputs 1 – 4: 0.02% /°C IEC 60601-1:2005 Third Edition GENERAL SPECIFICATIONS CAN/CSA-C22.2 No. 60950-1-07, UL Recognition Means of Protection nd 2 Edition Mark for Canada Primary to Secondary 2MOOP (Means of Operator Protection) CAN/CSA-C22.2 No. 601-1-M90, 2005 Primary to Ground 1MOOP (Means of Operator Protection) File E137708/E140259 CAN/CSA-C22.2 No. 60601-1:2008 Secondary to Ground Operational Insulation(Consult factory for 1MOOP or 1MOPP) EN 60950-1/A1:2010 Dielectric Strength(17) TUV E N 60601-1/A2:1995 Reinforced Insulation 5656 VDC, Primary to Secondary, 1 Sec. EN 60601-1:2006 Basic Insulation 2545 VDC, Primary to Ground, 1 Sec. Operational Insulation 707 VDC, Secondary to Ground, 1 Sec. Low Voltage Directive Leakage Current (2006/95/EC of December 2006) Earth Leakage <300uA NC, <1000uA SFC MODEL LISTING Touch Current <100uA NC, <500uA SFC Power Fail Signal Logic low with input power failure 10 mS MODEL OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 (8) (8) (7) (7) minimum prior to Output 1 dropping 1% REL-110-4001 +3.3V/10A +5V/6A +12V/2A -12V/2A (1) Remote Sense (singles only) 250mV compensation of output cable losses REL-110-4002 +5V/10A(1) +3.3V/6A +12V/2A -12V/2A REL-110-4003 +5V/10A +3.3V/6A +15V/2A -15V/2A Mean-Time Between Failures 100,000 Hours min., MIL-HDBK-217F, 25° C, GB (1) REL-110-4004 +5V/10A(1) -5V/6A +12V/2A -12V/2A Weight 0.80 Lbs. Open Frame/ 1.28 Lbs. Chassis and Cover REL-110-4005 +5V/10A(1) -5V/6A +15V/2A -15V/2A ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS REL-110-4006 +5V/10A +24V/2A +12V/2A -12V/2A (1) Electrostatic Discharge EN 61000-4-2 ±8kV Contact/ ±8kV Air Discharge REL-110-4007 +5V/10A(1) +24V/2A +15V/2A -15V/2A Radiated Electromagnetic Field En 61000-4-3 80MHz-2.5GHz, 10/m, 80% AM REL-110-4009 +5V/10A +24V/2A +7V/2.5A -7V/2.5A (1) EFT/Bursts EN 61000-4-4 ±2 kV REL-110-3001 +5V/10A(1) +12V/3A -12V/3A Surges EN 61000-4-5 ± 1 kV Common Mode REL-110-3002 +5V/10A +15V/2A -15V/2A (1) ±2 kV Differential Mode REL-110-3003 +8V/6A -8V/1A +30V/1A Conducted Immunity EN 61000-4-6 .15 to 80MHz, 10V, 80% AM REL-110-3004 +9V/3A -24V/3A +13V/2A Voltage Dips and Interruptions EN 61000-4-11 30% Reduction, 500ms REL-110-2001 +3.3V/10A +5V/6A (1) 95% Reduction, 10ms REL-110-2002 +5V/10A +12V/5A (1) 60% Reduction, 1s (Criteria B) REL-110-2003 +5V/10A(1) +24V/3A REL-110-2004 +12V/5A -12V/4A 95% Reductions, 5000ms REL-110-2005 +15V/4A -15V/3A Radiated Emissions EN 55011/22 Class B REL-110-2006 +18V/4A -18V/3A Conducted Emissions EN 55011/22 Class B REL-110-1001 2.5V/22A(2) Harmonic Current Emissions EN 61000-3-2 REL-110-1002 3.3V/22A (2) Voltage Fluctuations and Flicker EN 61000-3-3 REL-110-1003 5V/22A(2) NOTES REL-110-1004 12V/9.2A Consult factory for alternate output configurations. REL-110-1005 15V/7.3A Consult factory for positive, negative or floating outputs. REL-110-1006 24V/4.6A Refer to Applications Information for complete output power ratings. REL-110-1007 28V/3.9A All specifications are maximum at 25° C, 110W unless otherwise stated, may vary by REL-110-1008 48V/2.3A model and are subject to change without notice. Specify optional chassis and cover when ordering. REV.B 6/7/12 REL-110 Series Mechanical Specifications APPLICATIONS INFORMATION 1. Rated 8A maximum with convection cooling. 2. Rated 16A maximum with convection cooling. 3. Total power must not exceed 80 watts with convection cooling on open frame models except where noted. 4. Total power must not exceed 110 watts with 300 LFM forced air cooling on open frame models. 5. Total power must not exceed 65 watts with convection cooling and chassis/cover option. 6. Total power must not exceed 110 watts with 300 LFM forced air cooling and chassis/cover option. 7. Total current from Outputs 3 & 4 must not exceed 3 amps with convection cooling. . 8. Total current from Outputs 1 & 2 must not exceed 12 amps with convection cooling. 9. Semiconductor case temperatures must not exceed 110°C. 10. Each output can deliver its rated current but total output power must not exceed maximum power as determined by the cooling method stated above. 11. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air to develop. 12. 300 linear feet per minute of airflow must be maintained one inch above any point of the heatsink in the direction shown when forced air cooling is required. 13. This product is intended for use as a professionally installed component within information technology and medical equipment. 14. A minimum load of 10% is required on output one to ensure proper regulation of remaining outputs. 15. Remote sense terminals may be used to compensate for cable losses up to 250mV (single output models only). The use of a twisted pair is recommended as well as a . decoupling capacitor (0.1 - 10µF) and a capacitor of 100µF/amp connected across the load side. 16. Peak to peak output ripple and noise is measured directly at the output terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth. 17. This product was type tested and safety certified using the dielectric strength test voltages listed in Table 6 of IEC 60601-1:2005. In consideration of Clause 8.8.3, care must be taken to insure that the voltage applied to a reinforced insulation does not overstress different types and levels of insulation. Primary and secondary to ground capacitors may need to be disconnected prior to performing a dielectric strength test on the power supply or the end product. It is highly recommended that the DC test voltages listed in DVB.1, st Annex DVB of UL 60601-1 1 Edition are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information. 18. This power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing an AC dielectric strength test. 19. Maximum screw penetration into bottom chassis mounting holes is .100 inches. 20. Maximum screw penetration into side chassis mounting holes is .250 inches. 21. To meet emissions specifications, all four mounting hole pads must be electrically connected to a common metal chassis. Chassis/cover option recommended. 22. This product includes only one fuse in the input circuit. In consideration of Clause 8.11.5 of IEC 60601-1:2005, a second fuse may be required in the end product. MAXIMUM OUTPUT POWER VS. AMBIENT TEMPERATURE 110 100 FORCED AIR COOLING 90 80 CONVECTION COOLING 70 60 CONVECTION COOLING 50 WITH CHASSIS / COVER 40 30 20 10 0 0 10 20 30 40 50 60 70 Ambient Temperature (C) Connector Specifications P1 AC Input .156 friction lock header mates with Tyco 640250-3 or equivalent crimp terminal housing with Tyco 3-640706-1 or equivalent crimp terminal. P2 DC Output .156 friction lock header mates with Tyco 770849-8 or (Single) equivalent crimp terminal housing with Tyco 3-640707-1 or equivalent crimp terminal. P2 DC Output .156 friction lock header mates with Tyco 1-770849-0 or (Multiple) equivalent crimp terminal housing with Tyco 3-640707-1 or equivalent crimp terminal. G Ground .187 quick disconnect terminal. P3 P.F./Sense .100 breakaway header mates with Molex 50-57-9006 or (Single) equivalent crimp terminal housing with Molex type 71851 or equivalent crimp terminal. RECOMMENDED AIR FLOW DIRECTION P3 P.F. .100 breakaway header mates with Molex 50-57-9002 or (Multiple) equivalent crimp terminal housing with Molex type 71851 or 1 – Optimum 2 – Good 3 – Fair equivalent crimp terminal. Output Power (Watts)
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the REL-110-1003 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods