Description

0-5 AC Output Voltage, 4000 AC Output Current, 20 Power1 (kVA), 380V, 480 V, or 600V, Std. Input2 (Single Phase) with Air Insulation

Part Number

705-20

Price

Request Quote

Manufacturer

HIPOTRONICS

Lead Time

Request Quote

Category

AC DIELECTRIC TEST SETS

Datasheet

pdf file

Hipotronics-700 Series_AC_DIELECTRIC-ds1-2117998017.pdf

2050 KiB

Extracted Text

700 Series AC Dielectric Test Sets High Voltage AC Test Systems „ Hipotronics standard line of AC Test FEATURES Systems are designed to perform high voltage AC tests on electrical apparatus in accordance ; Continuously adjustable test output voltage with IEC60, IEEE 4 and IEC 270 and other ; Designed to operate from 10% to 100% of the national test standards. A variety of maximum rated output voltage mechanical configurations are available to suit different installation conditions. Some models ; Easily accessible meter recalibration access can be supplied in mobile versions when it is ; Adjustable Overload from 10 to 100% of rated difficult to move the test object to the test current output area. ; Backup Breaker overload safety situation ; Output Connected voltmeter and ammeter Hipotronics AC Dielectric Test Sets are available in a wide range of voltage and power ; Zero start interlock ensures that the voltage control is at a minimum before HV can be energized ratings with exceptional reliability, durability and functionality. No matter what your ; Rated current available from zero to rated voltage requirement, Hipotronics has an affordably priced, highly reliable test solution to meet your needs. BENEFITS Simple to Use – minimal amount of setup time and intuitive control panel allows simple testing Surge-compensated HV transformer windings for withstanding flashovers at full voltage Output Connected Meters ensures for fast accurate readings Surge and Transient Protection on all meters, transformers, etc. Partial Discharge Testing - low PD levels available at full output voltage (PD level needs to be specified when ordering and may require additional components) APPLICATIONS Î Rotating Machines Î Switchgear Î Insulating Materials Î Instrument Transformers Î Connectors Î Transformers Standard System Controller Î Capacitors Î Bushings CAC-PLC: Auto & Manual Programmable Logic Controller Î Sample Cable Lengths Î Transmission Line Hardware Î Arrestors Î HV Components STANDARD OPTIONS • OT248 Windows XP Based AC System Controller • Partial Discharge Free AC Sources • Remote PLC controller* *Note: Standard AC dielectric systems have PLC controller mounted into the regulator cabinet. For a remote PLC, an optional line item must be quoted. SELECTING AN AC TEST SET CURRENT VERSUS CAPACITIVE LOAD In order to properly size an AC Test Set, it is necessary to have the If the load is predominantly capacitive, the test current following information: required can be calculated by using the following formula: 1. Maximum test voltage required The maximum test A = 2πƒCV voltage is determined by the relevant standard that equipment is being built to plus any additional user- Where: defined over sizing to take into account changes to test standards, or special end-user requirements. 2. The power rating to determine the power rating, the • A = Test current in Amps capacitance, resistance or inductance of the load must be • ƒ = Test frequency in Hertz known. High voltage test objects are usually capacitive in nature. • C = Total test load capacitance in Farads 3. PD requirements Partial discharge testing is usually • V = Test voltage in Volts performed at lower levels than AC withstand levels. If PD testing is required it is necessary to know the PD sensitivity level for the test and the test voltage. Once these four things are known, the test voltage and load current can be used to determine the rating of the Specifying too high a PD test voltage or unnecessarily low system. We suggest that you consider rating your system PD free rating for the system inflates the cost of a test 10 to 20% higher in voltage and up to 50% higher in system. current to accommodate future, unanticipated test 4. Environment Most testing is done indoors in reasonable requirement changes. environments. If the HV test transformer is to be located outdoor or in a harsh environment, bushing size and tank design will change. ACCESSORIES 2820a & 2840 C / tanδ bridges DDX Series Partial Discharge Detectors TECHNICAL SPECIFICATIONS 1kVA Power Rating General 705-1 710-1 715-1 720-1 730-1 120V, 60Hz –A version Input Voltage 230V, 50Hz –B version Max Output Voltage 5kV AC 10kV AC 15kV AC 20kV AC 30kV AC Output Current 200mA 100mA 67mA 50mA 33mA Output Connection Shielded Cable Output Epoxy Output Bushing Metering 4.5" analog meters, ±2% full scale accuracy Duty Cycle 1kVA 1 hr. ON, 1 hr. OFF 6 times per day 1kVA 1 hr. ON, 1 hr. Off 6 times per day 21.25”W x 15”H x 15.625”D Control Dimensions (540mm x 381mm x 391mm) Control Net 85lbs (39kg) Net 81lbs (37kg) Weights High Voltage 12”W x 12”H x 11”D In Controller Dimensions (305mm x 305mm x 279mm) High Voltage In Controller 40lbs (18kg) 45lbs (20kg) Weight Regulator In Controller Dimensions Regulator Weight In Controller Note: Dimensions and Weights are Approximate 2kVA Power Rating General 705-2 710-2 715-2 730-2 750-2 120V, 60Hz –A version Input Voltage 230V, 50Hz –B version Max Output Voltage 5kV AC 10kV AC 15kV AC 30kV AC 50kV AC Output Current 400mA 200mA 133mA 67mA 40mA Output Connection Shielded Cable Output Epoxy Output Bushing Metering 4.5" analog meters, ±2% full scale accuracy Duty Cycle 1kVA 1 hr. ON, 1 hr. OFF 6 times per day 1kVA 1 hr. ON, 1 hr. Off 6 times per day Control / Regulator 21.25”W x 15”H x 15.625”D Dimensions (540mm x 381mm x 391mm) Control / Regulator Net 95lbs (43kg) Net 70lbs (32kg) Weights 12”W x 12”H x 11”D 14”W x 14”H x 12”D High Voltage In Control / Regulator Section (305 x 305 x (356 x 356 x Dimensions 279mm) 305mm) High Voltage In Control / Regulator Section Net 60lbs (27kg) Net 72lbs (33kg) Weight Note: Dimensions and Weights are Approximate 5kVA Power Rating General 705-5 715-5 730-5 775-5 7100-5 230V, 50/60Hz Input Voltage Other Inputs Available, Consult Factory Max Output Voltage 5kV AC 15kV AC 30kV AC 75kV AC 100kV AC Output Current 1000mA 333mA 167mA 67mA 50mA Output Connection Shielded Output Cable Epoxy Output Bushing Metering Digital, 1% of FS, range 10-100% of system output Duty Cycle 1 hr. ON, 1 hr. OFF / Continuous @ 4kVA Control/Regulator 23”W x 51”H x 26”D 21.25”W x 20.50”H x 19.625”D Dimensions (584 x 1295 x 660mm) (540 x 521 x 498mm) Control/Regulator Net 550bs (250kg) Net 150lbs (68kg) Weights High Voltage 21”Wx23”Hx36”D 21”Wx36”Hx40”D 21”Wx36”Hx48”D In Control / Regulator Section Dimensions (533x914x991mm) (533x914x1016mm) (533x914x1219mm) High Voltage In Control / Regulator Section Net 450lbs (204kg) Net 850lbs (386kg) Net 1100lbs (499kg) Weight Note: Dimensions and Weights are Approximate • Other Output Ratings Available, Consult Factory with Your Requirements 10kVA Power Rating General 705-10 715-10 730-10 775-10 7100-10 230V, 50/60Hz Input Voltage Other Inputs Available, Consult Factory Max Output Voltage 5kV AC 15kV AC 30kV AC 75kV AC 100kV AC Output Current 2000mA 667mA 333mA 133mA 100mA Output Connection Shielded Output Cable Epoxy Output Bushing Metering Digital, 1% of FS, range 10-100% of system output Duty Cycle 10kVA 1 hr. ON, 1 hr. OFF/Continuous @ 7.5kVA Control / Regulator 23”W x 51”H x 26”D Dimensions (584mm x 1295mm x 660mm) Control / Regulator Net 600lbs (272kg) Net 550lbs (250kg) Weights High Voltage 21”Wx23”Hx36”D 21”Wx36”Hx40”D 21”Wx36”Hx48”D In Control / Regulator Section Dimensions (533x914x991mm) (533x914x1016mm) (533x914x1219mm) High Voltage Weight In Control / Regulator Section Net 550lbs (250kg) Net 1000lbs (454kg) Net 1100lbs (499kg) Note: Dimensions and Weights are Approximate • Other Output Ratings Available, Consult Factory with Your Requirements • Porcelain Condenser Bushings are used on systems rated >100kV with a approximate load rating of 400pF 20kVA Power Rating General 705-20 715-20 730-20 775-20 7100-20 480V, single phase, 60Hz Input Voltage 380V, single phase, 50Hz Max Output Voltage 5kV AC 15kV AC 30kV AC 75kV AC 100kV AC Output Current 4000mA 1333mA 667mA 267mA 200mA Output Connection Shielded Output Cable Epoxy Output Bushing Metering Digital, 1% of FS, range 10-100% of system output Duty Cycle 20kVA 1 hr. ON, 1 hr. OFF/ Continuous @ 15kVA Control / Regulator 25”W x 73”H x 25”D Dimensions (635 x 1855 x 635mm) Control / Regulator Net 750lbs (340kg) Net 600lbs (272kg) Weights High Voltage 21”Wx36”Hx39”D 21”Wx36”Hx40”D 21”Wx36”Hx48”D In Control / Regulator Section Dimensions (533x914x991mm) (533x914x1016mm) (533x914x1219mm) High Voltage In Control / Regulator Section Net 900lbs (408kg) Net 950lbs (432kg) 1300lbs (590kg) Weight Note: Dimensions and Weights are Approximate • Other Output Ratings Available, Consult Factory with Your Requirements • Porcelain Condenser Bushings are used on systems rated >100kV with a approximate load rating of 400pF 40kVA Power Rating General 705-40 710-40 715-40 720-40 750-40 7100-40 480V, single phase, 60Hz Input Voltage 380V, single phase, 50Hz Max Output Voltage 5kV AC 10kV AC 15kVA AC 20kV AC 50kV AC 100kV AC Output Current 8000mA 4000mA 2666mA 2000mA 800mA 400mA Output Connection Shielded Output Cable Epoxy Output Bushing Metering Digital, 1% of FS, range 10-100% of system output Duty Cycle 40kVA 1 hr. ON, 1 hr. OFF/Continuous @ 30kVA Control / Regulator 30”W x 73”H x 42”D 25”W x 73”H x 30”D Dimensions (762 x 1855 x 1067mm) (635 x 1855 x 672mm) Control / Regulator Net 1300lbs, (590kg) 800lbs (363kg) Weights High Voltage 21”Wx36”Hx39”D 21”Wx36”Hx39”D 30”Wx40”Hx48”D In Control / Regulator Section Dimensions (533x914x991mm) (533x914x991mm) (533x914x991mm) High Voltage Net 1200lbs Net 1700lbs Net 2070lbs In Control / Regulator Section Weight (544kg) (771kg) (941kg) Note: Dimensions and Weights are Approximate • Other Output Ratings Available, Consult Factory with Your Requirements • Porcelain Condenser Bushings are used on systems rated >100kV with a approximate load rating of 400pF 60kVA Power Rating General 705-60 720-60 760-60 7100-60 480V, single phase, 60Hz Input Voltage 380V, single phase, 50Hz Max Output Voltage 5kV AC 20kV AC 60kV AC 100kV AC Output Current 12000mA 3000mA 1000mA 600mA Output Connection Shielded Output Cable Epoxy Output Bushing Metering Digital, 1% of FS, range 10-100% of system output Duty Cycle 60kVA 1 hr. ON, 1 hr. OFF/ Continuous @ 50kVA Control / Regulator 30”W x 73”H x 42”D 25”W x 73”H x 30”D Dimensions (762 x 1855 x 1067mm) (635 x 1855 x 672mm) Control / Regulator Net 1500lbs (680kg) 900lbs (408kg) Weights High Voltage In Control / Regulator 29”Wx37”Hx40”D 34”Wx42”Hx49”D 34”Wx48”Hx55”D Dimensions Section 737x940x1016mm 864x1067x1245mm 864x1220x1397mm High Voltage In Control / Regulator Net 1600lbs Net 2000lbs Net 2540lbs Weight Section (726 kg) (907 kg) (1155 kg) Note: Dimensions and Weights are Approximate • Other Output Ratings Available, Consult Factory with Your Requirements • Porcelain Condenser Bushings are used on systems rated >100kV with a approximate load rating of 400pF 100kVA Power Rating General 720-100 750-100 775-100 7100-100 480V, single phase, 60Hz Input Voltage 380V, single phase, 50Hz Max Output Voltage 20kV AC 50kV AC 75kV AC 100kV AC Output Current 5000mA 2000mA 1333mA 1000mA Output Connection Epoxy Output Bushing Metering Digital, 1% of FS, range 10-100% of system output Duty Cycle 100kVA 1 hr. ON, 1 hr. OFF/Continuous @ 75kVA Control / Regulator 30”W x 73”H x 42”D Dimensions (762 x 1855 x 1067mm) Control / Regulator Net 1400lbs (635 kg) Weights High Voltage 30”Wx39”Hx40”D 30”Wx39”Hx40”D 34”Wx45”Hx58”D 34”Wx42”Hx53D Dimensions 762x991x1016mm 762x991x1016mm 864x1143x1473mm 864x1067x1346mm High Voltage Net 2600lbs Net 2800lbs Net 2900lbs Net 3100lbs Weight (1182 kg) (1273 kg) (1315 kg) (1409 kg) Note: Dimensions and Weights are Approximate • Other Output Ratings Available, Consult Factory with Your Requirements • Porcelain Condenser Bushings are used on systems rated >100kV with a approximate load of 400pF Europe, Asia, South & Central America, China North America Australia Haefely Test AG – Beijing Office Hipotronics Inc. Haefely Test AG 8-1-602, Fortune Street 1650 Route 22 Birsstrasse 300 No. 67, Chaoyang Road, Chaoyang District PO Box 414 4052 Basel Beijing, 100025 Brewster, NY 10509 Switzerland P. R. China USA + 41 61 373 4111 + 86 10 8578 8099 + 1 845 279 3644  + 41 61 373 4912  + 86 10 8578 9908  + 1 845 279 2467 | sales@haefely.com.cn | sales@tettex.com | sales@hipotronics.com Hipotronics has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice AC_Dielectric_DS_03_2012

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 705-20 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

0-5 AC Output Voltage, 200 AC Output Current, 1 Power1 (kVA) with Air Insulation

0-5 AC Output Voltage, 2000 AC Output Current, 10 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single...

0-5 AC Output Voltage, 400 AC Output Current, 2 Power1 (kVA), 50/60Hz Std. Input2 (Single Phase) wit...

0-5 AC Output Voltage, 8000 AC Output Current, 40 Power1 (kVA), 480 Vac, 50/60Hz Std. Input2 (Single...

0-5 AC Output Voltage, 1000 AC Output Current, 5 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single ...

ETH LAN BOARD 10MB PCI