Elite.Parts chervon right Manufacturers chervon right H chervon right HAMMOND MANUFACTURING chervon right PT500MQMJ
About product Specifications Datasheet FAQ

HAMMOND MANUFACTURING PT500MQMJ

Image of HAMMOND MANUFACTURING PT500MQMJ

Description

Hammond Manufacturing PT500MQMJ Control Transformer

Part Number

PT500MQMJ

Price

Request Quote

Manufacturer

HAMMOND MANUFACTURING

Lead Time

Request Quote

Category

PRODUCTS - P

Specifications

Amps

4.35A

Overall Dimensions

5.25x5.00x4.50

Weight

21.95 lbs

Datasheet

pdf file

PT500MQMJ-Hammond-datasheet-1937937421.pdf

392 KiB

Extracted Text

SECTION 1 SECTION 1 PT SERIES CONTROL TRANSFORMERS SECTION 9 For detailed mounting dimensions by VA size, please refer to diagrams on Page 47. B B C C Mounting Mounting Slot GxH Slot GxH D D E E A A F F FIGURE A FIGURE B Group AA SCHEMATIC CONNECTIONS Primary Supply Lines Install Jumpers Primary Volts Connect To Between Lines 240/480, 230/460, 220/440 H1 H3 H2 H4 240 H1, H4 H1-H3, H2-H4 Voltage 230 H1, H4 H1-H3, H2-H4 220 H1, H4 H1-H3, H2-H4 480 H1, H4 H3-H2 Secondary 460 H1, H4 H3-H2 120, 115, 110 440 H1, H4 H3-H2 Voltage 120V 115V Sec. Load Lines Install Jumpers X2X1 110V Volts Connect To Between Lines XF 120 X2, XF 50/60 Hertz 115 X2, XF 110 X2, XF VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25MQMJ A 0.22 3.00 3.25 2.75 2.50 1.75 2.50 .22 X .44 2.35 50 PT50MQMJ A 0.43 3.00 3.75 2.75 2.50 2.25 3.41 .22 X .75 3.60 75 PT75MQMJ A 0.65 3.00 4.00 2.75 2.50 2.44 3.31 .22 X .50 4.35 100 PT100MQMJ A 0.87 3.00 4.50 2.75 2.50 2.63 3.50 .22 X .50 5.15 150 PT150MQMJ A 1.30 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 6.15 200 PT200MQMJ A 1.74 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 7.75 250 PT250MQMJ A 2.17 4.50 4.50 3.85 3.13/3.75 3.00 4.00 .22 X .75 9.50 300 PT300MQMJ A 2.61 4.50 4.75 3.85 3.13/3.75 3.00 4.00 .22 x .75 10.75 350 PT350MQMJ A 3.04 5.00 5.00 3.85 3.75/4.38 3.56 4.56 .22 X .75 11.75 500 PT500MQMJ A 4.35 5.25 5.00 4.50 3.75/4.38 4.00 5.00 .31 X .75 14.75 750 PT750MQMJ A 6.52 5.63 5.88 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 21.95 1000 PT1000MQMJ A 8.70 5.63 6.88 4.50 4.38/5.31 5.50 7.00 .31 X 1.13 28.70 1500 PT1500MQMJ B 13.04 7.00 5.75 5.50 4.50/6.00 5.13 6.50 .38 x 1.00 33.00 2000 PT2000MQMJ B 17.39 7.00 7.50 5.50 4.50/6.00 6.13 7.50 .38 x 1.00 41.50 3000 PT3000MQMJ B 26.09 7.50 8.88 6.38 4.50/6.00 7.00 8.38 .38 x 1.00 71.50 5000 PT5000MQMJ B 43.48 9.00 10.00 7.63 5.25/7.00 7.25 8.75 .44 x 1.00 106.00 Height dimension (C) does not include fuse clip (applicable up to 1000VA Primary The output amps listed above are based on a 115V secondary. jumpers are included. Secondary fuse clips for 13/32” X 1 1/2” fuse included up to All dimensions in inches unless otherwise speciŢ ed. 1000VA. Open style units (1500VA to 5000VA) do not carry the CE mark. 35 Data subject to change without notice. © Hammond Power Solutions Inc. SECTION 1 PT SERIES CONTROL TRANSFORMERS Group BB SCHEMATIC CONNECTIONS Primary 575, 460, 230 575V H1 H4 Voltage Primary Supply Lines Install Jumpers H3 460V Volts Connect To Between Lines 230V H2 575 H1, H4 Secondary 460 H1, H3 115, 95 230 H1, H2 Voltage Sec. Load Lines Install Jumpers 95V Volts Connect To Between Lines X2 115V 115 X1, X3 50/60 Hertz X3 X1 95 X1, X2 VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25MBMH A 0.22 3.00 3.50 2.75 2.50 1.75 2.50 .22 X .44 2.35 50 PT50MBMH A 0.43 3.00 3.75 2.75 2.50 2.25 3.41 .22 X .75 3.60 75 PT75MBMH A 0.65 3.00 4.00 2.75 2.50 2.44 3.31 .22 X .50 4.35 100 PT100MBMH A 0.87 3.00 4.50 2.75 2.50 2.63 3.50 .22 X .50 5.15 150 PT150MBMH A 1.30 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 6.15 200 PT200MBMH A 1.74 4.50 4.00 3.85 3.13/3.75 2.75 3.63 .22 X .75 7.75 250 PT250MBMH A 2.17 4.50 4.75 3.85 3.13/3.75 3.00 4.00 .22 X .75 9.50 300 PT300MBMH A 2.61 4.50 4.75 3.85 3.13/3.75 3.00 4.00 .22 x .75 10.75 350 PT350MBMH A 3.04 5.00 5.50 3.85 3.75/4.38 3.56 4.56 .22 X .75 11.75 500 PT500MBMH A 4.35 5.25 5.00 4.50 3.75/4.38 4.00 5.00 .31 X .75 14.75 750 PT750MBMH A 6.52 5.63 6.38 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 21.75 1000 PT1000MBMH A 8.70 6.00 6.88 5.07 4.38/5.31 5.50 7.00 .31 X 1.13 28.95 1500 PT1500MBMH B 13.05 7.00 6.25 5.50 4.50/6.00 5.13 6.50 .38 x 1.00 33.00 2000 PT2000MBMH B 17.39 7.00 7.50 5.50 4.50/6.00 6.13 7.50 .38 x 1.00 41.50 3000 PT3000MBMH B 26.09 7.50 10.88 6.38 4.50/6.00 7.28 8.66 .38 x 1.00 73.50 5000 PT5000MBMH B 43.48 9.00 11.50 7.63 5.25/7.00 7.78 9.25 .44 x 1.00 115.00 Primary jumpers and Secondary fuse clips are not applicable. Secondary jumpers The output amps listed above are based on a 115V secondary. are included. Open style units (1500VA to 5000VA) do not carry the CE mark. All dimensions in inches unless otherwise speciŢ ed. Group CC SCHEMATIC CONNECTIONS Primary 240/480 Primary Supply Lines Install Jumpers Voltage H1 H3 H2 H4 Volts Connect To Between Lines 480 H1, H4 H2-H3 Secondary 240 H1, H4 H1-H3, H2-H4 24 Voltage Sec. Load Lines Install Jumpers 24V X2X1 Volts Connect To Between Lines XF 24 X2, XF 50/60 Hertz VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25QG A 1.04 3.00 3.25 2.75 2.50 1.75 2.50 .22 X .44 2.35 50 PT50QG A 2.08 3.00 3.75 2.75 2.50 2.50 3.41 .22 X .75 3.60 75 PT75QG A 3.13 3.00 4.00 2.75 2.50 2.44 3.31 .22 X .50 4.35 100 PT100QG A 4.17 3.00 4.50 2.75 2.50 2.63 3.50 .22 X .50 5.15 150 PT150QG A 6.25 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 6.15 200 PT200QG A 8.33 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 7.75 250 PT250QG A 10.40 4.50 4.50 3.85 3.13/3.75 3.00 4.00 .22 X .75 9.50 300 PT300QG A 12.50 4.50 4.75 3.85 3.13/3.75 3.00 4.00 .22 x .75 10.75 350 PT350QG A 14.60 5.00 5.00 3.85 3.75/4.38 3.56 4.56 .22 X .75 11.75 500 PT500QG A 20.80 5.25 5.00 4.50 3.75/4.38 4.00 5.00 .31 X .75 14.75 750 PT750QG A 31.30 5.63 5.88 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 21.95 Height dimension (C) does not include secondary fuse clip. All dimensions in inches unless otherwise speciŢ ed. Primary jumpers and Secondary fuse clips for 13/32” X 1 1/2” fuse are included. 36 Data subject to change without notice. © Hammond Power Solutions Inc. SECTION 1 SECTION 1 SECTION 1 PT SERIES CONTROL TRANSFORMERS SECTION 9 For detailed mounting dimensions by VA B size, please refer to diagrams on Page 47. C Mounting Slot GxH D E A F FIGURE A Group DD SCHEMATIC CONNECTIONS Primary 120/240 H1 H4 Primary Supply Lines Install Jumpers Voltage H3 H2 Volts Connect To Between Lines 120 H1, H4 H1-H3, H2-H4 Secondary 240 H1, H4 H2-H3 24 Voltage Sec. Load Lines Install Jumpers 24V X2X1 Volts Connect To Between Lines XF 24 X2, XF 50/60 Hertz VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25PG A 1.04 3.00 3.25 2.75 2.50 1.75 2.50 .22 X .44 2.35 50 PT50PG A 2.08 3.00 3.75 2.75 2.50 2.25 3.41 .22 X .75 3.60 75 PT75PG A 3.13 3.00 4.00 2.75 2.50 2.44 3.31 .22 X .50 4.35 100 PT100PG A 4.17 3.00 4.50 2.75 2.50 2.63 3.50 .22 X .50 5.15 150 PT150PG A 6.25 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 6.15 200 PT200PG A 8.33 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 7.75 250 PT250PG A 10.40 4.50 4.50 3.85 3.13/3.75 3.00 4.00 .22 X .75 9.50 300 PT300PG A 12.50 4.50 4.75 3.85 3.13/3.75 3.00 4.00 .22 x .75 10.75 350 PT350PG A 14.60 5.00 5.00 3.85 3.75/4.38 3.56 4.56 .22 X .75 11.75 500 PT500PG A 20.80 5.25 5.00 4.50 3.75/4.38 4.00 5.00 .31 X .75 14.75 750 PT750PG A 31.30 5.63 5.88 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 21.95 Height dimension (C) does not include secondary fuse clip. All dimensions in inches unless otherwise speciŢ ed. Primary jumpers and Secondary fuse clips for 13/32” X 1 1/2” fuse are included. 37 Data subject to change without notice. © Hammond Power Solutions Inc. SECTION 1 PT SERIES CONTROL TRANSFORMERS Group EE SCHEMATIC CONNECTIONS Primary 480 H1 H2 Voltage 480V Primary Supply Lines Install Jumpers Volts Connect To Between Lines 480 H1, H2 Secondary 240 Voltage Sec. Load Lines Install Jumpers X2 240V X1 Volts Connect To Between Lines XF 240 X2, XF 50/60 Hertz VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25CM A 0.10 3.00 3.25 2.75 2.50 1.75 2.50 .22 X .44 2.35 50 PT50CM A 0.21 3.00 3.75 2.75 2.50 2.25 3.41 .22 X .75 3.60 75 PT75CM A 0.31 3.00 4.00 2.75 2.50 2.44 3.31 .22 X .50 4.35 100 PT100CM A 0.42 3.00 4.50 2.75 2.50 2.63 3.50 .22 X .50 5.15 150 PT150CM A 0.63 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 6.15 200 PT200CM A 0.83 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 7.75 250 PT250CM A 1.04 4.50 5.00 3.85 3.13/3.75 3.00 4.00 .22 X .75 9.50 350 PT350CM A 1.46 5.00 5.00 3.85 3.75/4.38 3.56 4.56 .22 X .75 11.75 500 PT500CM A 2.08 5.25 5.00 3.85 3.75/4.38 4.00 5.00 .31 X .75 14.75 750 PT750CM A 3.13 5.63 5.88 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 21.75 1000 PT1000CM A 4.17 5.63 6.38 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 29.95 Height dimension (C) does not include secondary fuse clip. All dimensions in inches unless otherwise speciŢ ed. Secondary fuse clips for 13/32” X 1 1/2” fuse are included. Primary jumpers not applicable. Group FF SCHEMATIC CONNECTIONS Primary 460, 230, 208 460V H4 H1 Voltage Primary Supply Lines Install Jumpers H3 230V Volts Connect To Between Lines 460 H1, H4 208V H2 Secondary 230 H1, H3 115 208 H1, H2 Voltage Sec. Load Lines Install Jumpers Volts Connect To Between Lines X2 115V X1 115 X2, XF 50/60 Hertz XF VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25MLI A 0.22 3.00 3.25 2.75 2.50 1.75 2.50 .22 X .44 2.35 50 PT50MLI A 0.43 3.00 3.75 2.75 2.50 2.25 3.41 .22 X .75 3.60 75 PT75MLI A 0.65 3.00 4.00 2.75 2.50 2.44 3.31 .22 X .50 4.35 100 PT100MLI A 0.87 3.00 4.50 2.75 2.50 2.63 3.50 .22 X .50 5.15 150 PT150MLI A 1.30 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 6.15 200 PT200MLI A 1.74 4.50 4.00 3.85 3.13/3.75 2.75 3.63 .22 X .75 7.75 250 PT250MLI A 2.17 4.50 4.75 3.85 3.13/3.75 3.00 4.00 .22 X .75 9.50 300 PT300MLI A 2.61 4.50 4.75 3.85 3.13/3.75 3.00 4.00 .22 x .75 10.75 350 PT350MLI A 3.04 5.00 5.00 3.85 3.75/4.38 3.56 4.56 .22 X .75 11.75 500 PT500MLI A 4.35 5.25 5.00 4.50 3.75/4.38 4.00 5.00 .31 X .75 14.75 750 PT750MLI A 6.52 5.63 6.38 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 21.75 1000 PT1000MLI A 8.70 6.00 6.38 5.07 4.38/5.31 5.00 6.50 .31 X 1.13 28.95 Height dimension (C) does not include secondary fuse clip. All dimensions in inches unless otherwise speciŢ ed. Secondary fuse clips for 13/32” X 1 1/2” fuse are included. Primary jumpers not applicable. 38 Data subject to change without notice. © Hammond Power Solutions Inc. SECTION 1 SECTION 1 PT SERIES CONTROL TRANSFORMERS Group HH SCHEMATIC CONNECTIONS Primary 415, 380 415V Voltage Primary Supply Lines Install Jumpers H3 H1 Volts Connect To Between Lines 415 H1, H3 380V H2 Secondary 380 H1, H2 110/220 Voltage Sec. Load Lines Install Jumpers Volts Connect To Between Lines 110 X1, X4 X1-X3, X2-X4 X4 X2 X3 X1 50/60 Hertz 220 X1, X4 X2-X3 VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25MDMX A 0.23/0.11 3.00 3.25 2.75 2.50 1.75 2.50 .22 X .44 2.35 50 PT50MDMX A 0.45/0.23 3.00 3.75 2.75 2.50 2.25 3.41 .22 X .75 3.60 75 PT75MDMX A 0.68/0.34 3.00 4.00 2.75 2.50 2.44 3.31 .22 X .50 4.35 100 PT100MDMX A 0.91/0.45 3.00 4.50 2.75 2.50 2.63 3.50 .22 X .50 5.15 150 PT150MDMX A 1.36/0.68 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 6.15 200 PT200MDMX A 1.82/0.91 4.25 4.00 3.25 3.13/3.75 2.75 3.63 .22 X .75 7.75 250 PT250MDMX A 2.27/1.14 4.50 4.50 3.85 3.13/3.75 3.00 4.00 .22 X .75 9.50 350 PT350MDMX A 3.18/1.59 5.00 5.00 3.85 3.75/4.38 3.56 4.56 .22 X .75 11.75 500 PT500MDMX A 4.55/2.27 5.25 5.00 3.85 3.75/4.38 4.00 5.00 .31 X .75 14.75 750 PT750MDMX A 6.82/3.41 6.00 5.88 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 21.74 1000 PT1000MDMX A 9.09/4.55 5.63 6.88 4.50 4.38/5.31 5.50 7.00 .31 X 1.13 28.95 Secondary jumpers are included. Primary jumpers and secondary fuse clips are not applicable. All dimensions in inches unless otherwise speciŢ ed. Group II SCHEMATIC CONNECTIONS Primary 380, 277, 208 380V H1 H4 Primary Supply Lines Install Jumpers Voltage H3 277V Volts Connect To Between Lines 208V 380 H1, H4 H2 Secondary 277 H1, H3 208 H1, H2 120 Voltage Sec. Load Lines Install Jumpers Volts Connect To Between Lines X2 120V X1 120 X2, XF 50/60 Hertz XF VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25MGJ A 0.21 3.00 3.25 2.75 2.50 1.75 2.50 .22 X .44 2.35 50 PT50MGJ A 0.42 3.00 3.75 2.75 2.50 2.25 3.41 .22 X .75 3.60 75 PT75MGJ A 0.63 3.00 4.00 2.75 2.50 2.44 3.31 .22 X .50 4.35 100 PT100MGJ A 0.83 3.00 4.00 2.75 2.50 2.63 3.50 .22 X .50 5.15 150 PT150MGJ A 1.25 4.25 4.50 3.25 3.13/3.75 2.75 3.63 .22 X .75 6.15 200 PT200MGJ A 1.67 4.50 4.00 3.85 3.13/3.75 2.75 3.63 .22 X .75 7.75 250 PT250MGJ A 2.08 4.50 4.00 3.85 3.13/3.75 3.00 4.00 .22 X .75 9.50 300 PT300MGJ A 2.50 4.50 4.75 3.85 3.13/3.75 3.00 4.00 .22 x .75 10.75 350 PT350MGJ A 2.92 5.00 4.75 3.85 3.75/4.38 3.56 4.56 .22 X .75 11.75 500 PT500MGJ A 4.17 5.25 5.00 4.50 3.75/4.38 4.00 5.00 .31 X .75 14.75 750 PT750MGJ A 6.25 5.63 5.00 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 21.75 1000 PT1000MGJ A 8.33 5.63 6.38 4.50 4.38/5.31 5.00 6.50 .31 X 1.13 28.95 Height dimension (C) does not include secondary fuse clip. All dimensions in inches unless otherwise speciŢ ed. Secondary fuse clips for 13/32” X 1 1/2” fuse are included. Primary jumpers not applicable. 40 Data subject to change without notice. © Hammond Power Solutions Inc. SECTION 1 SECTION 1 PT SERIES CONTROL TRANSFORMERS B For detailed mounting dimensions by VA size, please refer to diagrams on Page 47. C Mounting Slot GxH D E A F FIGURE A Group LL SCHEMATIC CONNECTIONS Primary Primary Supply Lines Install Jumpers 240/480 H1 Volts Connect To Between Lines H3 H2 H4 Voltage 480 H1, H4 H2-H3 240 H1,H4 H1-H3, H2-H4 Secondary 12/24 Voltage Sec. Load Lines Install Jumpers Volts Connect To Between Lines X4X2 X3 X1 12 X1, X4 X1-X3, X2-X4 50/60 Hertz 24 X1, X4 X2-X3 VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25QR A 2.08/1.04 3.00 3.25 2.75 2.50 1.75 2.50 .22 X .44 2.35 50 PT50QR A 4.17/2.08 3.00 3.75 2.75 2.50 2.25 3.41 .22 X .75 3.60 75 PT75QR A 6.25/3.13 3.00 4.00 2.75 2.50 2.44 3.31 .22 X .50 4.35 100 PT100QR A 8.33/4.17 3.00 4.50 2.75 2.50 2.63 3.50 .22 X .50 5.15 150 PT150QR A 12.5/6.25 4.25 4.00 3.25 3.13/3.75 2.63 3.63 .22 X .75 6.15 200 PT200QR A 16.7/8.33 4.25 4.00 3.25 3.13/3.75 2.63 3.63 .22 X .75 7.75 250 PT250QR A 20.8/10.4 4.50 4.50 3.85 3.13/3.75 3.00 4.00 .22 X .75 9.50 Primary and Secondary jumpers are included. Secondary fuse clips are not applicable. All dimensions in inches unless otherwise speciŢ ed. Group MM SCHEMATIC CONNECTIONS Primary Primary Supply Lines Install Jumpers H1 H2 H3 H4 415, 400, 380 Volts Connect To Between Lines Voltage 415V H1, H4 400V H1, H3 Secondary 380V H1, H2 110/220 Sec. Load Lines Install Jumpers Voltage Volts Connect To Between Lines 110V X1, X4 X1-X3, X2-X4 X4 X2 X3 X1 50/60 Hertz 220V X1, X4 X2-X3 VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25MEMX A 1.04/0.22 3.00 3.25 2.75 2.50 1.75 2.50 0.22 x 0.44 2.35 50 PT50MEMX A 2.08/0.43 3.00 3.75 2.75 2.50 2.25 3.41 0.22 x 0.75 3.60 75 PT75MEMX A 3.13/0.65 3.00 4.00 2.75 2.50 2.44 3.31 0.22 x 0.50 4.35 100 PT100MEMX A 4.17/0.87 3.00 4.50 2.75 2.50 2.63 3.50 0.22 x 0.50 5.15 150 PT150MEMX A 6.25/1.30 4.25 4.13 3.25 3.13/3.75 2.75 3.75 0.22 x 0.75 6.15 200 PT200MEMX A 8.33/1.74 4.25 4.13 3.25 3.13/3.75 2.75 3.75 0.22 x 0.75 7.75 250 PT250MEMX A 10.42/2.17 4.50 4.88 3.85 3.12/3.75 3.00 4.00 0.22 x 0.75 9.50 350 PT350MEMX A 14.58/3.04 4.88 5.38 3.85 3.75/4.38 3.56 4.56 0.22 x 0.75 11.75 500 PT500MEMX A 20.83/4.35 5.25 5.00 3.85 3.75/4.38 4.00 5.00 0.22 x 0.75 14.75 750 PT750MEMX A 31.25/6.52 6.00 6.00 4.50 4.38/5.31 5.00 6.50 0.31 x 1.13 21.74 1000 PT1000MEMX A 41.67/8.70 6.00 7.00 4.50 4.38/5.31 5.00 6.50 0.31 x 1.13 28.95 Primary jumpers and Secondary fuse clips are not applicable. Secondary jumpers are included. All dimensions are inches unless otherwise speciŢ ed. *Hammond does not offer European style metric fuse clips. 42 Data subject to change without notice. © Hammond Power Solutions Inc. SECTION 1 0V 380V 400V 415V SECTION 1 PT SERIES CONTROL TRANSFORMERS Group OO SCHEMATIC CONNECTIONS Primary 380, 277, 208 H1 H2 H3 H4 Primary Supply Lines Install Jumpers Voltage Volts Connect To Between Lines 380V H1, H4 Secondary 277V H1, H3 208V H1, H2 24, 120 Voltage Sec. Load Lines Install Jumpers Volts Connect To Between Lines X3X2X1 XF 120V X1, X3 50/60 Hertz 24V X1, X2 VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25MGMD A 1.04/0.21 3.00 3.25 2.75 2.50 1.75 2.50 0.22 x 0.44 3.60 50 PT50MGMD A 2.08/0.42 3.00 4.00 2.75 2.50 2.25 3.41 0.22 x 0.75 4.35 75 PT75MGMD A 3.13/0.63 3.00 4.50 2.75 2.50 2.88 3.75 0.22 x 0.50 5.15 100 PT100MGMD A 4.17/0.83 3.75 4.13 3.25 3.12 2.75 3.50 0.22 x 0.56 5.61 150 PT150MGMD A 6.25/1.25 4.50 4.38 3.85 3.12/3.75 2.63 3.63 0.22 x 0.75 6.15 200 PT200MGMD A 8.33/1.67 4.50 4.88 3.85 3.12/3.75 2.63 3.63 0.22 x 0.75 7.75 250 PT250MGMD A 10.42/2.08 4.50 5.38 3.85 3.12/3.75 3.00 4.00 0.22 x 0.75 9.40 350 PT350MGMD A 14.58/2.92 4.88 5.88 3.85 3.75/4.38 3.56 4.56 0.22 x 0.75 11.75 500 PT500MGMD A 20.83/4.17 5.50 5.00 3.85 3.75/4.38 4.00 5.00 0.22 x 0.75 14.75 Height dimension (C) does not include secondary fuse clip. All dimensions are inches unless otherwise speciŢ ed. Secondary fuse clips for 13/32” x 1 1/2” fuse included. Primary jumpers not applicable. *Hammond does not offer European style metric fuse clips. Group PP SCHEMATIC CONNECTIONS Primary 415, 400, 240 H1 H2 H3 H4 Voltage Primary Supply Lines Install Jumpers Volts Connect To Between Lines 415V H1, H4 Secondary 400V H1, H3 24, 120 240V H1, H2 Voltage Sec. Load Lines Install Jumpers Volts Connect To Between Lines X3 X2 X1 120V X1, X3 XF 50/60 Hertz 24 X1, X2 VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25MCMD A 1.04/0.21 3.00 3.25 2.75 2.50 1.75 2.50 0.22 x 0.44 3.60 50 PT50MCMD A 2.08/0.42 3.00 4.00 2.75 2.50 2.25 3.41 0.22 x 0.75 4.35 75 PT75MCMD A 3.13/0.63 3.00 4.50 2.75 2.50 2.88 3.75 0.22 x 0.50 5.15 100 PT100MCMD A 4.17/0.83 3.75 4.13 3.25 3.12 2.75 3.50 0.22 x 0.56 5.61 150 PT150MCMD A 6.25/1.25 4.50 4.38 3.85 3.12/3.75 2.63 3.63 0.22 x 0.75 6.15 200 PT200MCMD A 8.33/1.67 4.50 4.88 3.85 3.12/3.75 2.63 3.63 0.22 x 0.75 7.75 250 PT250MCMD A 10.42/2.08 4.50 5.38 3.85 3.12/3.75 3.00 4.00 0.22 x 0.75 9.40 350 PT350MCMD A 14.58/2.92 4.88 5.88 3.85 3.75/4.38 3.56 4.56 0.22 x 0.75 11.75 500 PT500MCMD A 20.83/4.17 5.50 5.00 3.85 3.75/4.38 4.00 5.00 0.22 x 0.75 14.75 Height dimension (C) does not include secondary fuse clip. All dimensions are inches unless otherwise speciŢ ed. Secondary fuse clips for 13/32” x 1 1/2” fuse included. Primary jumpers not applicable. *Hammond does not offer European style metric fuse clips. 44 Data subject to change without notice. © Hammond Power Solutions Inc. SECTION 1 120V 0V 120V 0V 208V 240V 24V 24V 400V 277V 0V 0V 415V 380V SECTION 1 PT SERIES CONTROL TRANSFORMERS Group RR SCHEMATIC CONNECTIONS Primary 240/480 Primary Supply Lines Install Jumpers Voltage H1 H3 H2 H4 Volts Connect To Between Lines 240 H1, H4 H1-H3, H2-H4 Secondary 480 H1, H4 H2-H3 120/240 Voltage Sec. Load Lines Install Jumpers X4X2 X3 X1 Volts Connect To Between Lines 120 X1, X4 X1-X3, X2-X4 50/60 Hertz 240 X1, X4 X2-X3 VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25QP A 0.21/0.10 3.00 3.25 2.75 2.50 1.75 2.50 0.22 x 0.44 2.25 50 PT50QP A 0.42/0.21 3.00 3.75 2.75 2.50 2.25 3.41 0.22 x 0.75 3.50 75 PT75QP A 0.63/0.31 3.00 4.00 2.75 2.50 2.44 3.31 0.22 x 0.50 4.25 100 PT100QP A 0.83/0.42 3.00 4.50 2.75 2.50 2.63 3.50 0.22 X 0.50 5.00 150 PT150QP A 1.25/0.63 4.25 4.25 3.25 3.12/3.75 2.75 3.75 0.22 x 0.75 6.00 200 PT200QP A 1.67/0.83 4.50 4.38 3.85 3.12/3.75 2.63 3.63 0.22 x 0.75 7.25 250 PT250QP A 2.08/1.04 4.50 4.88 3.85 3.12/3.75 3.00 4.00 0.22 x 0.75 9.25 300 PT300QP A 2.50/1.25 4.50 4.88 3.85 3.12/3.75 3.00 4.00 0.22 x 0.75 10.50 350 PT350QP A 2.92/1.46 4.88 5.38 3.85 3.75/4.38 3.56 4.56 0.22 x 0.75 11.50 500 PT500QP A 4.17/2.08 5.25 5.13 4.50 3.75/4.38 4.00 5.00 0.22 x 0.75 14.50 750 PT750QP A 6.25/3.13 6.00 5.88 4.50 4.38/5.31 5.00 6.50 0.31 x 1.13 21.50 1000 PT1000QP A 8.33/4.17 6.00 6.92 4.50 3.75/4.38 5.50 7.00 0.31 x 1.13 29.58 Primary and Secondary jumpers are included. Secondary fuse clips are not applicable. All dimensions in inches unless otherwise speciŢ ed. Group SS SCHEMATIC CONNECTIONS Primary 120/240 Voltage Primary Supply Lines Install Jumpers H1 H3 H2 H4 Volts Connect To Between Lines 120 H1, H4 H1-H3, H2-H4 Secondary 240 H1, H4 H2-H3 120/240 Voltage Sec. Load Lines Install Jumpers X4X2 X3 X1 Volts Connect To Between Lines 120 X1, X4 X1-X3, X2-X4 50/60 Hertz 240 X1, X4 X2-X3 VA Catalog Mtg. Output Overall Dimensions Mounting Centers Mtg. Slot Shipping Rating Number Fig. Amps “A” “B” “C” “D” “E” “F” “G X H” Wt/Lbs 25 PT25PP A 0.21/0.10 3.00 3.25 2.75 2.50 1.75 2.50 0.22 x 0.44 2.25 50 PT50PP A 0.42/0.21 3.00 3.75 2.75 2.50 2.25 3.41 0.22 x 0.75 3.50 75 PT75PP A 0.63/0.31 3.00 4.00 2.75 2.50 2.44 3.31 0.22 x 0.50 4.25 100 PT100PP A 0.83/0.42 3.00 4.50 2.75 2.50 2.63 3.50 0.22 X 0.50 5.00 150 PT150PP A 1.25/0.63 4.25 4.25 3.25 3.12/3.75 2.75 3.75 0.22 x 0.75 6.00 200 PT200PP A 1.67/0.83 4.50 4.38 3.85 3.12/3.75 2.63 3.63 0.22 x 0.75 7.25 250 PT250PP A 2.08/1.04 4.50 4.88 3.85 3.12/3.75 3.00 4.00 0.22 x 0.75 9.25 300 PT300PP A 2.50/1.25 4.50 4.88 3.85 3.12/3.75 3.00 4.00 0.22 x 0.75 10.50 350 PT350PP A 2.92/1.46 4.88 5.38 3.85 3.75/4.38 3.56 4.56 0.22 x 0.75 11.50 500 PT500PP A 4.17/2.08 5.25 5.13 4.50 3.75/4.38 4.00 5.00 0.22 x 0.75 14.50 750 PT750PP A 6.25/3.13 6.00 5.88 4.50 4.38/5.31 5.00 6.50 0.31 x 1.13 21.50 1000 PT1000PP A 8.33/4.17 6.00 6.92 4.50 3.75/4.38 5.50 7.00 0.31 x 1.13 29.58 Primary and Secondary jumpers are included. Secondary fuse clips are not applicable. All dimensions in inches unless otherwise speciŢ ed. 46 Data subject to change without notice. © Hammond Power Solutions Inc. SECTION 1

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the PT500MQMJ have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Panel, Rack; 19 in.; 5.25 in.; Aluminum; Smooth Beige; 0.125 in.; 4

product

Panel, Rack; 19 in.; 12.25 in.; Aluminum; Smooth Beige; 0.125 in.; 8

product

Panel, Rack; 19 in.; 14 in.; Aluminum; Smooth Beige; 0.125 in.; 8

product

Panel, Rack; 19 in.; 15.75 in.; Aluminum; Smooth Beige; 0.125 in.; 8

product

Panel, Rack; 19 in.; 15.75 in.; Aluminum; 0.125 in.; 8

product

Panel, Rack; 19 in.; 19.25 in.; Aluminum; Smooth Beige; 0.125 in.; 8