FIRETROL FTA1100-JL12N

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number FTA1100-JL12N
Manufacturer FIRETROL
Category PRODUCTS - F
Price Request Quote
Lead Time Request Quote

Description

Firetrol FTA1100-JL12N Diesel Engine Fire Pump Controller. FTA1100 Mark II | 12V Negative Ground

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Elite.Parts is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a FTA1100-JL12N? We can help you find it at a competitive price!

Features

  • AC Line & Battery circuit breakers
  • Door mounted display/interface panel featuring a 128 x 64 pixel backlit LED graphical display
  • Manual test push-button
  • Manual-Off-Auto selector switch
  • Two 10 Amp battery chargers with 4 stage charging cycle, selectable AC voltage (110 / 220), selectable DC voltage (12 / 24), and selectable battery type (Lead Acid, Ni-Cad 9/18 Cell, Ni-Cad 10/20 Cell
  • Two manual crank push-buttons

Datasheet

Download "Firetrol-FTA1100-JL12N-Controller-datasheet1-254111409.pdf" (100 KiB)

Extracted Text

FTA1100J Diesel Engine Fire Pump Controllers Product Description • MAIN SWITCH IN MANUAL • SYSTEM PRESSURE LOW • ENGINE RUNNING • ENGINE FAIL TO START • ENGINE TEMPERATURE HIGH • ENGINE OIL PRESSURE LOW • ENGINE OVERSPEED • ENGINE ALTERNATE ECM • ENGINE FUEL INJECTOR MALFUNCTION • FUEL LEVEL LOW • AUTOMATIC SHUTDOWN DISABLED • CHARGER MALFUNCTION • BATTERY #1 TROUBLE • BATTERY #2 TROUBLE • Minimum Run Timer / Off Delay Timer • Programmable Daylight Saving Time Option • Weekly Test Timer ® • Engine Run Time Meter Description – Firetrol combined automatic and manual • Digital Pressure Display Mark IIXG based diesel engine Ţ re pump controllers are • USB Host Controller and Port intended for starting and monitoring Ţ re pump diesel • Solid State Pressure Transducer engines. They are suitable for use with both mechanical • Data Log and electronic type engines. The controller is available for • Event Log (3000 events) 12 or 24 volt negative ground systems, using lead acid • Simultaneous Display of Battery Voltages, Charging or Nickel-Cadmium batteries. The controller monitors, Rates, AC Volts, Pressure and Alarm Messages displays and records Ţ re pump system information. • Disk Error Message • Disk Near Full Message Approvals – Firetrol Ţ re pump controllers are listed by • Pressure Error Message Underwriters’ Laboratories, Inc., in accordance with • Fail to Start Message UL218, Standard for Fire Pump Controllers, CSA, Standard • Low Suction Pressure Message for Industrial Control Equipment (cUL), and approved by • Crank Cycle Status Indication (Displays Cranking Bat- Factory Mutual. They are built to meet or exceed the tery, Number of Starting Attempts and Crank/Rest requirements of the approving authorities as well as Time Remaining) NEMA and the latest editions of NFPA 20, Installation • 300 psi (20.7 bars) wet parts (solid state pressure of Centrifugal Fire Pumps, and NFPA 70, National Electri- transducer, solenoid valve, plumbing) for fresh water cal Code. applications • NEMA Type 2 enclosure (IEC IP22) Standard Features – The following are included as stan- • Each standard controller comes with user set options dard with each controller: for: • AC Line & Battery circuit breakers • AC Power Loss Start • Interlock Alarm • Manual-Off-Auto selector switch • Low Pressure Aud. • Low Suction • Manual test push-button • Main Sw. Mis-Set • Manual Test • Two manual crank push-buttons • Pump Run Alarm • Remote Start • Two 10 Amp battery chargers with 4 stage charging • User DeŢ ned Input • Weekly Test Setup cycle, selectable AC voltage (110 / 220), selectable DC • Low Pump Rm Temp • Low Reservoir voltage (12 / 24), and selectable battery type (Lead • Relief Valve Open • High Fuel Level Acid, Ni-Cad 9/18 Cell, Ni-Cad 10/20 Cell) • High Reservoir • Door mounted display/interface panel featuring a 128 x 64 pixel backlit LCD graphical display, Membrane Type User Control Push-buttons and easy to read LED Indicators for: • AC POWER AVAILABLE • ALARM • MAIN SWITCH IN AUTO -CPL Contacts for remote indication, system Special Enclosures 115% over pressure (for use with PLD engines only) -T NEMA Type 3R (IEC IP22), Painted Steel -CTS Built-in low suction pressure alarm panel (Includes select- -E NEMA Type 4 (IEC IP 66), Painted Steel able auto/manual reset, audible, visible and remote alarms -F NEMA Type 4X (IEC IP66) #304 Stainless and mounted and wired pressure switch) Steel, Brushed Finish -EE Additional contacts for remote indication, engine trouble - 1 -FXP NEMA Type 4X (IEC IP66) #304 Stainless set provided as standard Steel, Painted Finish -EF Additional contacts for remote indication, main switch -FD NEMA Type 4X (IEC IP66) #316 Stainless mis-set - 1 set provided as standard Steel, Brushed Finish 1 -EH Contacts for remote indication, relief valve discharge -FDB NEMA Type 4X (IEC IP66) #316 Stainless 1 -EJ Audible & Visible ţ ow meter on alarm Steel, 12 Gauge, Seam Welded, 1 -EK Contacts for remote indication, ţ ow meter on (Requires Brushed Finish option -EJ) -FDP NEMA Type 4X (IEC IP66) #316 Stainless -JR Visible jockey pump running indication Steel, Painted Finish -JT Audible and visible jockey pump trouble indication -G NEMA Type 12 (IEC IP54) 1 -LC Contacts for remote indication, high fuel level 1 -LD Audible & Visible fuel spill alarm Mounting Legs 1 -LE Contacts for remote indication, fuel spill (Requires option -N31 Standard 12” Mounting Legs -LD) -N31S 12” Mounting Legs, Stainless Steel 1 -LG Contacts for remote indication, reservoir high -PE Contacts for remote indication, low system pressure Anti-Condensation Space Heaters (Pump On Demand) -H 120 Volt Space Heater -J 120 Volt Space Heater with Thermostat Miscellaneous -K 120 Volt Space Heater with Humidistat -AZ Low pump room temperature switch, mounted and wired -L 240 Volt Space Heater -BA 220-240 Volt operation -M 240 Volt Space Heater with Thermostat -EL Series pumping, high zone controller -N 240 Volt Space Heater with Humidistat -EM Series pumping, mid zone controller -EN Series pumping, low zone controller Pressure Transducers, Solenoid Valves, Plumbing -IEC CE Marking with Externally Mounted Wet Parts -B 0-600 psi (0-41.4 bars) wet parts for fresh water applications -IECI CE Marking (Internal Wet Parts) -C 0-300 psi (0-20.7 bars) wet parts for copper corrosive -OSP OSHPD Seismic CertiŢ cation (State of California) (Requires applications Option -SEI) -D 0-600 psi (0-41.4 bars) wet parts for copper corrosive -S Tropicalization applications -SEI Seismic CertiŢ cation (in accordance with IBC) -USBX External USB Port Alarms -ZPA Customized, annual service display message (factory -AC Additional contacts for remote indication, engine running - 2 programmed) sets provided as standard -ZPN Serial Modbus RTU over Ethernet TCP/IP -AJ Contacts for remote indication, engine overspeed using 5150 Connectivity Module -AK Contacts for remote indication, low oil pressure -ZPM Serial Modbus RTU over 2-wire or 4-wire RS485 -AL Contacts for remote indication, high water temperature -AM Contacts for remote indication, engine failed to start 2 FTA1100-K1 Low fuel level switch, 16” max insertion length -AN Contacts for remote indication, battery / charger failure FTA1100-K1-X High/Low fuel level switch - specify levels/tank -AP Contacts for remote indication, main switch in manual dimensions -AR Contacts for remote indication, main switch in off 2 FTA1100-K2 Low fuel level switch, 25” max. insertion length -AS Contacts for remote indication, main switch in auto 1 2 FTAK21 380-480 volt operation (transformer) -AT Contacts for remote indication, pump room trouble Export packaging (Wooden crating to conform to IPPC Standards) -AV Contacts for remote indication, low pump room 1 temperature 1 -AW Contacts for remote indication, reservoir low 1 1 - Initiating switches by others -AY Contacts for remote indication, low suction pressure 2 - Shipped loose for installation by the customer -COM Visible low suction pressure alarm, Manual reset only (Includes reset push-button, initiating 1 pressure switch not included)

Related Products

FIRETROL
DIESEL ENGINE FIRE PUMP CONTROLLER
FIRETROL
DIESEL ENGINE FIRE PUMP CONTROLLER
FIRETROL
FIRETROL FTA-1100-M MICROCONTROLLER 24V DIESEL FIRE PUMP CONTROLLER
FIRETROL
FIRETROL Control Board

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Elite.Parts are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Elite.Parts is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.05 seconds.