FESTO VADMI-200-P
Specifications
Design
Slim rectangular
Ejector features
High vacuum
Max. vacuum
80%
Mounting position
Any
Nominal size
0.5 … 1.5 mm
Operating medium
Compressed air, unlubricated, grade of filtration to 40 µm
Temperature range
–20 …+80 °C
Type of mounting
Either: Via female thread, via through-holes
Datasheet
Extracted Text
Solenoid-Actuated Vacuum Generators Features and Benefits Solenoid-Actuated Vacuum Generators Electrical Connection Ejector Pulse Types VADM-... / VADMI-... for Vacuum Generation (Type VADMI-...) ll Integral Filter, Silencer, Manual Override Integral Silencer ll Integral Solenoid Valve for Controlling Air Supply Electrical Supply Port ll Vacuum Range up to approximately Connection for 25 in Hg depending on application Vacuum Sensor ll Venturi Nozzle Diameters: 0.45, 0.70, 0.95, 1.4, 2.0, 3.0 mm Vacuum Port ll Vacuum Ports: M5 to G 3/8 Potentiometer for Setting ll Supply Ports: M5 to G 1/4 Hysteresis ll Available Features: Integral Filter - Vacuum Switch (-P, -N) - Ejector Pulse (VADMI) Potentiometer - Air-Saving Vacuum Switch for Setting (VADMI-...-LS-...) Switching Point Connection for External Vacuum Sensing Pages 25-38 Solenoid-Actuated Vacuum Generators Type VAD-M-... ll Integral Silencer, Manual Override Socket with Cable (Order Separately) Ejector Pulse ll Integral Solenoid Valve for (Type VAD-...-I-....) Controlling Air Supply ll Vacuum Range up to approximately 25 in Hg depending on application Integral Silencer ll Venturi Nozzle Diameters: 0.45, Supply Port 0.70, 0.95, 1.4, 2.0 mm ll Vacuum Ports: M5 to G 3/8 ll Supply Ports: M5 to G 1/4 ll Available with Ejector Pulse Vacuum Port (VAD-...-I-...) Pages 39-47 24 Subject to change pneuaire Solenoid-Actuated Vacuum Generators With Integral Filter and Silencer, Optional Vacuum Switch, Type VADM-… Type VADM-… Type VADM-…-P/N Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM-… with integral filter, silencer and vacuum switch Type VADM-…-P (PNP output) Air supply to these vacuum generators is controlled by the internal solenoid VADM-…-N (NPN output) valve. When electrical power energizes the solenoid, the valve is actuated and compressed air flows from port 1 to port 3. This generates a vacuum at port 2 by means of the venturi principle. Suction cups can be connected to vacuum connection (2). Air entering vacuum connection (2) passes through an internal filter and is discharged to atmosphere, together with the supply air, via exhaust port 3. An integrated silencer reduces exhaust-air noise. When the solenoid valve is deenergized, vacuum generation ceases. 1 = Supply Port Types VADM-…-P/N includes a vacuum switch which allows the vacuum level 2 = Vacuum Connection to be monitored. (See page 38 for technical data on the vacuum switch.) 3 = Exhaust Ordering Information, see pages 8-10 KMYZ, KMEB, MSSD-EB, Solenoid Sockets, see pages 84-89 Order Number Solenoid-Actuated 162500 162501 162502 162503 162504 162505 Part No./Type Vacuum Generator VADM-45 VADM-70 VADM-95 VADM-140 VADM-200 VADM-300 With Vacuum Switch 162512 162514 162516 162518 162520 162522 (PNP Output) VADM-45-P VADM-70-P VADM-95-P VADM-140-P VADM-200-P VADM-300-P With Vaccum Switch 162513 162515 162517 162519 162521 162523 (NPN Output) VADM-45-N VADM-70-N VADM-95-N VADM-140-N VADM-200-N VADM-300-N Replacement Filters 348145 348146 348149 348147 348147 348148 Venturi Nozzle Diameter 0.018 in / 0.028 in / 0.037 in / 0.055 in / 0.079 in / 0.118 in / 0.45 mm 0.7 mm 0.95 mm 1.4 mm 2.0 mm 3.0 mm Medium Compressed air, filtered (40 µm), unlubricated Integral Vacuum Filter 40 µm Design Venturi principle, single solenoid valve, manual override Mounting Through holes in housing, threaded Connection Ports 1 / 2 M5 / M5 M5 / G 1/8 G 1/8 / G 1/8 G 1/8 / G 1/4 G 1/4 / G 3/8 G 1/4 / G 3/8 Pressure Range 15 to 120 psi / 1 to 8 bar (Optimum operating pressure 75 to 105 psi / 5 to 7 bar) Air Consumption, Vacuum, Evacuation Time, See graphs on pages 36-37 Efficiency, Noise Level Ambient Temperature 32 to 122°F / 0 to +50°C Medium Temperature 32 to 122°F / 0 to +50°C Materials Housing: anodized aluminum; Silencer: polymethylene oxide, polyethylene; Filter: polyethylene, polyamid 66, post-chlorinated; Seals: Buna N Weight without Vacuum Switch 0.132 lb / 0.309 lb / 0.463 lb / 0.639 lb / 0.706 lb / 0.750 lb / 0.060 kg 0.140 kg 0.210 kg 0.290 kg 0.320 kg 0.340 kg with Vacuum Switch 0.143 lb / 0.320 lb / 0.485 lb / 0.661 lb / 0.728 lb / 0.772 lb / 0.065 kg 0.145 kg 0.220 kg 0.300 kg 0.330 kg 0.350 kg Type of Protection IP 65 Solenoid Valve Switching Voltage 24 VDC Power Consumption 1.4 W 1.5 W, pilot actuated Switch-on Time 5 ms Duty Cycle 100% per VDE 0580 Connection Socket with Cable Type KMYZ-2-24-…-LED Type KMEB-1-24-…-LED Socket without Cable – – Type MSSD-EB Subject to change (Ref. 2.4/10-1) (97/98) 25 pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VADM-… Type VADM-45 Type VADM-70 1 Supply Port 2 Vacuum Connection 3 Manual Override 4 Mounting Thread 5 Mounting Hole 6 Solenoid coil can be repositioned by 180° 7 Suitable for Socket Type KMYZ-... Type B1 B2 B3 D1 D2 D3 D4 H1 H2 in / mm in / mm in / mm in / mm in / mm in / mm VADM-45 0.39 / 10 0.24 / 6.2 0.39 / 10 M5 M5 0.13 / 3.2 M2 2.54 / 64.4 1.75 / 44.4 VADM-70 0.59 / 15 0.44 / 11.2 0.59 / 15 G 1/8 M5 0.13 / 3.2 M2 2.91 / 73.9 1.94 / 49.4 Type H3 H4 H5 H6 H7 L1 L2 L4 L5 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-45 1.61 / 40.8 0.94 / 23.8 0.94 / 23.8 1.16 / 29.6 0.71 / 18 2.20 / 56 1.61 / 41 1.32 / 33.6 0.98 / 25 VADM-70 1.85 / 47 1.04 / 26.5 0.92 / 23.5 1.30 / 32.9 0.71 / 18 2.89 / 73.3 2.30 / 58.3 1.59 / 40.4 0.83 / 21 Type L6 L7 L8 L9 L10 L11 L12 L13 L14 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-45 0.14 / 3.6 0.43 / 11 0.63 / 16 1.61 / 41 2.20 / 56 0.31 / 7.9 0.08 / 1.9 1.43 / 36.3 0.16 / 4 VADM-70 0.56 / 14.2 0.43 / 11 0.87 / 22 2.06 / 52.4 3.00 / 76.1 0.37 / 9.4 0.08 / 1.9 2.11 / 53.7 0.18 / 4.5 26 (Ref. 2.4/10-2) (97/98) Subject to change pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VADM-… Type VADM-95 Type VADM-140 Type VADM-200 Type VADM-300 1 Supply Port 2 Vacuum Connection 3 Manual Override 4 Mounting Thread 5 Mounting Hole 6 Solenoid coil can be repositioned by 180° 7 Suitable for Socket Type KMEB-... and MSSD-EB Type B1 B2 B3 D1 D2 D3 D4 H1 H2 in / mm in / mm in / mm in / mm in / mm in / mm VADM-95 0.71 / 18 0.53 / 13.4 0.71 / 18 G 1/8 G 1/8 0.16 / 4.2 M3 3.68 / 93.4 2.50 / 63.4 VADM-140 0.87 / 22 0.65 / 16.6 0.71 / 18 G 1/4 G 1/8 0.20 / 5.2 M3 4.23 / 107.4 3.05 / 77.4 VADM-200 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.46 / 113.4 3.28 / 83.4 VADM-300 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.46 / 113.4 3.28 / 83.4 Type H3 H4 H5 H6 H7 L1 L2 L4 L5 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-95 1.92 / 48.9 1.00 / 25.5 0.92 / 23.3 1.30 / 33 0.71 / 18 2.91 / 73.8 2.40 / 61 1.70 / 43.3 0.34 / 8.7 VADM-140 2.42 / 61.4 1.63 / 41.4 1.63 / 41.4 1.42 / 36 0.69 / 17.5 3.81 / 96.8 3.31 / 84 1.02 / 26 0.49 / 12.5 VADM-200 2.66 / 67.7 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.75 / 19 3.81 / 96.8 3.31 / 84 1.02 / 26 0.49 / 12.5 VADM-300 2.66 / 67.7 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.75 / 19 5.24 / 133.2 4.74 / 120.4 1.02 / 26 0.49 / 12.5 Type L6 L7 L8 L9 L10 L11 L12 L13 L14 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-95 0.52 / 13.2 0.38 / 9.7 0.96 / 24.5 2.40 / 61 3.10 / 78.8 0.37 / 9.5 0.09 / 2.3 2.16 / 55 0.18 / 4.5 VADM-140 1.12 / 28.5 0.38 / 9.7 0.96 / 24.5 2.40 / 61 3.81 / 96.8 0.54 / 13.8 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADM-200 1.12 / 28.5 0.38 / 9.7 0.96 / 24.5 2.40 / 61 4.01 / 101.8 0.49 / 12.5 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADM-300 1.12 / 28.5 0.38 / 9.7 0.96 / 24.5 2.40 / 61 5.41 / 137.4 0.49 / 12.5 0.09 / 2.3 4.56 / 115.8 0.20 / 5 27 Subject to change (Ref. 2.4/10-2) (97/98) pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VADM-… Type VADM-45-P/N Type VADM-70-P/N 1 Supply Port 2 Vacuum Connection 3 Manual Override 4 Mounting Thread 5 Mounting Hole 6 Solenoid coil can be repositioned by 180° 7 Suitable for Socket Type KMYZ-... 8 Connection for Socket Type SIM-... Type B1 B2 B3 D1 D2 D3 D4 H1 H2 H3 in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-45-P/N 0.39 / 10 0.24 / 6.2 0.39 / 10 M5 M5 0.13 / 3.2 M2 2.54 / 64.4 1.75 / 44.4 1.61 / 40.8 VADM-70-P/N 0.59 / 15 0.44 / 11.2 0.59 / 15 G 1/8 M5 0.13 / 3.2 M2 2.91 / 73.9 1.94 / 49.4 1.85 / 47 Type H4 H5 H6 H7 L1 L2 L3 L4 L5 L6 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-45-P/N 0.94 / 23.8 0.94 / 23.8 1.16 / 29.6 0.71 / 18 2.64 / 67 1.61 / 41 0.94 / 24 1.32 / 33.6 0.98 / 25 0.14 / 3.6 VADM-70-P/N 1.04 / 26.5 0.92 / 23.5 1.30 / 32.9 0.71 / 18 3.32 / 84.3 2.30 / 58.3 0.94 / 24 1.59 / 40.4 0.83 / 21 0.56 / 14.2 Type L7 L8 L9 L10 L11 L12 L13 L14 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-45-P/N 0.43 / 11 0.63 / 16 1.61 / 41 2.20 / 56 0.31 / 7.9 0.08 / 1.9 1.43 / 36.3 0.16 / 4 VADM-70-P/N 0.43 / 11 0.87 / 22 2.06 / 52.4 3.00 / 76.1 0.37 / 9.4 0.08 / 1.9 2.11 / 53.7 0.18 / 4.5 28 (Ref. 2.4/10-3) (97/98) Subject to change pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VADM-… Type VADM-95-P/N Type VADM-140-P/N Type VADM-200-P/N Type VADM-300-P/N 1 Supply Port 2 Vacuum Connection 3 Manual Override 4 Mounting Thread 5 Mounting Hole 6 Solenoid coil can be repositioned by 180° 7 Suitable for Socket Type KMEB-... and MSSD-EB 8 Connection for Socket Type SIM-... Type B1 B2 B3 D1 D2 D3 D4 H1 H2 H3 in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-95-P/N 0.71 / 18 0.53 / 13.4 0.71 / 18 G 1/8 G 1/8 0.16 / 4.2 M3 3.68 / 93.4 2.50 / 63.4 1.92 / 48.9 VADM-140-P/N 0.87 / 22 0.65 / 16.6 0.71 / 18 G 1/4 G 1/8 0.20 / 5.2 M3 4.23 / 107.4 3.05 / 77.4 2.42 / 61.4 VADM-200-P/N 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.46 / 113.4 3.28 / 83.4 2.66 / 67.7 VADM-300-P/N 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.46 / 113.4 3.28 / 83.4 2.66 / 67.7 Type H4 H5 H6 H7 L1 L2 L3 L4 L5 L6 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-95-P/N 1.00 / 25.5 0.92 / 23.3 1.30 / 33 0.71 / 18 3.42 / 87 2.40 / 61 0.94 / 24 1.70 / 43.3 0.34 / 8.7 0.52 / 13.2 VADM-140-P/N 1.63 / 41.4 1.63 / 41.4 1.42 / 36 0.69 / 17.5 4.33 / 110 3.31 / 84 0.94 / 24 1.02 / 26 0.49 / 12.5 1.12 / 28.5 VADM-200-P/N 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.75 / 19 4.33 / 110 3.31 / 84 0.94 / 24 1.02 / 26 0.49 / 12.5 1.12 / 28.5 VADM-300-P/N 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.75 / 19 4.98 / 126.4 4.74 / 120.4 0.94 / 24 1.02 / 26 0.49 / 12.5 1.12 / 28.5 Type L7 L8 L9 L10 L11 L12 L13 L14 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADM-95-P/N 0.38 / 9.7 0.96 / 24.5 2.40 / 61 3.10 / 78.8 0.37 / 9.5 0.09 / 2.3 2.16 / 55 0.18 / 4.5 VADM-140-P/N 0.38 / 9.7 0.96 / 24.5 2.40 / 61 3.81 / 96.8 0.54 / 13.8 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADM-200-P/N 0.38 / 9.7 0.96 / 24.5 2.40 / 61 4.01 / 101.8 0.49 / 12.5 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADM-300-P/N 0.38 / 9.7 0.96 / 24.5 2.40 / 61 5.41 / 137.4 0.49 / 12.5 0.09 / 2.3 4.56 / 115.8 0.20 / 5 Subject to change (Ref. 2.4/10-3) (97/98) 29 pneuaire Solenoid-Actuated Vacuum Generators With Integral Filter, Silencer, Ejector Pulse, Optional Vacuum Switch and Air Saving Circuit Air supply to these Type VADMI-… Type VADMI-…-P/N vacuum generators is Solenoid-Actuated Vacuum controlled by the built-in Generator solenoid valves. When with integral filter, silencer, and ejector electrical power ener- pulse gizes the first solenoid, the valve is actuated Type VADMI-… and compressed air 1 = Supply Port flows from port 1 to 2 = Vacuum Connection port 3. This generates 3 = Exhaust a vacuum at port 2 by means of the venturi with vacuum switch: principle. Suction cups PNP output can be connected to Type VADMI-…-P vacuum connection (2). NPN output Air entering vacuum connection (2) passes through a built-in filter and is Type VADMI-…-N discharged to atmosphere, together with the supply air, via exhaust port 3. An integrated silencer reduces exhaust-air noise. with air-saving circuit (PNP output): When the first solenoid valve is deenergized, vacuum generation ceases. Type VADMI-…-LS-P Vacuum level is maintained by an integral non-return valve. Vacuum can be dissipated quickly by energizing the second solenoid of the double-solenoid This vacuum generator incorporates a ejector valve. The supply air is then redirected to port (2). This applied ejector vacuum switch with an air-saving function. pulse of positive pressure breaks the vacuum and quickly releases the part being held. The vacuum switch has two poten- tiometers which allow two points to be Types VADMI-…-P/N and VADMI-...-LS-P include a vacuum switch which defined between which the vacuum level allows the vacuum level to be monitored. (See page 38 for technical data on is adequate to securely hold a workpiece. the vacuum switch.) Connecting cables, sockets for solenoid coils, and vacuum switch are included. See page 31. Ordering Information, see pages 8-10 KMYZ, KMEB, MSSD-EB Solenoid Sockets, see pages 85-87 Order Number Solenoid-Actuated 162506 162507 162508 162509 162510 162511 Part No./Type Vacuum Generator VADMI-45 VADMI-70 VADMI-95 VADMI-140 VADMI-200 VADMI-300 With Vacuum Switch 162524 162526 162528 162530 162532 162534 (PNP Output) VADMI-45-P VADMI-70-P VADMI-95-P VADMI-140-P VADMI-200-P VADMI-300-P With Vacuum Switch 162525 162527 162529 162531 162533 162535 (NPN Output) VADMI-45-N VADMI-70-N VADMI-95-N VADMI-140-N VADMI-200-N VADMI-300-N Air Saving Circuit 171053 171055 171057 171059 171061 171063 (PNP Output) VADMI-45-LS-P VADMI-70-LS-P VADMI-95-LS-P VADMI-140-LS-P VADMI-200-LS-P VADMI-300-LS-P Replacement Filters 348145 348146 348149 348147 348147 348148 Venturi Nozzle Diameter 0.018 in / 0.028 in / 0.037 in / 0.055 in / 0.079 in / 0.118 in / 0.45 mm 0.7 mm 0.95 mm 1.4 mm 2.0 mm 3.0 mm Medium Compressed air, filtered (40 µm), unlubricated Integral Vacuum Filter 40 µm Design Venturi principle, solenoid valve, manual override Mounting Through holes in housing, threaded Connection Ports 1 / 2 M5 / M5 M5 / G 1/8 G 1/8 / G 1/8 G 1/8 / G 1/4 G 1/4 / G 3/8 G 1/4 / G 3/8 Pressure Range 15 to 120 psi / 1 to 8 bar (Optimum operating pressure 75 to 105 psi / 5 to 7 bar) Air Consumption, Vacuum, Evacuation Time, See graphs on pages 36 and 37 Efficiency, Noise Level Ambient Temperature 32 to 122°F / 0 to +50°C Medium Temperature 32 to 122°F / 0 to +50°C Materials Housing: anodized aluminum; Silencer: polymethylene oxide, polyethylene; Filter: polyethylene, polyamide 66, post-chlorinated PVC; Seals: Buna N Weight 0.187 lb / 0.375 lb / 0.529 lb / 0.706 lb / 0.772 lb / 0.816 lb / without Vacuum Switch 0.085 kg 0.170 kg 0.240 kg 0.320 kg 0.350 kg 0.370 kg 0.198 lb / 0.397 lb / 0.551 lb / 0.728 lb / 0.794 lb / 0.838 lb / with Vacuum Switch 0.090 kg 0.180 kg 0.250 kg 0.330 kg 0.360 kg 0.380 kg Type of Protection IP 65 Solenoid Valve Switching Voltage 24 VDC Power Consumption 2 x 1.4 W 2 x 1.5 W, pilot actuated Switch-on Time 5 ms Duty Cycle 100% per VDE 0580 Connection Socket with Cable Type KMYZ-2-24-…-LED Type KMEB-1-24-…-LED Socket without Cable – – Type MSSD-EB 30 (Ref.2.4/12-1, 12-2) (97/98) Subject to change pneuaire Solenoid-Actuated Vacuum Generators Vacuum Switch with Air Saving Circuit Vacuum Switch with Air Saving Circuit for Type VADMI-...-LS-P This switch generates a pulse signal (A2) only when the vacuum level falls to an insufficient preset threshold value, for example due to leakage. The pulse signal activates the suction solenoid of the vacuum generator, thus restoring the vacuum to another preset value. During the remaining cycle time, vacuum is maintained by the integral non-return valve eliminating the need to activate the suction solenoid. It is also possible to monitor a signal (A1) which is normally at +24V but which falls to 0V if the vacuum falls below the lower preset threshold by a further 65 mbar. This will, for example, occur if a workpiece falls off a suction cup, with the result that the desired vacuum level can no longer be generated. Connecting cables, sockets for solenoid coils, and vacuum switch are included. The switch must be operated only with the cable set supplied. Connections 1, 3 and 4 can be interchanged without causing damage to the switch. This unit is supplied complete with socket and cable assembly as shown below. Circuit diagram for vacuum switch PNP switching output BN = brown WH = white BK = black BU = blue RL = load 31 Subject to change (Ref. 2.4/12-8) (97/98) pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VADMI-… Type VADMI-45-P/N Type VADMI-70-P/N 1 Supply Port 2 Vacuum Connection 3 Manual Override 4 Mounting Thread 5 Mounting Hole 7 Suitable for Socket Type KMYZ-... Type B1 B2 B3 D1 D2 D3 D4 H1 H2 in / mm in / mm in / mm in / mm in / mm in / mm VADMI-45 0.39 / 10 0.24 / 6.2 0.39 / 10 M5 M5 0.13 / 3.2 M2 3.08 / 78.2 2.29 / 58.2 VADMI-70 0.59 / 15 0.44 /11.2 0.59 / 15 G 1/8 M5 0.13 / 3.2 M2 3.50 / 88.9 2.54 / 64.4 Type H3 H4 H5 H6 H7 L1 L2 L4 L5 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-45 1.61 / 40.8 0.94 / 23.8 0.94 / 23.8 1.71 / 43.4 0.71 / 18 2.20 / 56 1.61 / 41 1.32 / 33.6 0.98 / 25 VADMI-70 1.85 / 47 1.04 / 26.5 0.92 / 23.5 1.92 / 48.8 0.71 / 18 2.89 / 73.3 2.30 / 58.3 1.59 / 40.4 0.83 / 21 Type L6 L7 L8 L9 L10 L11 L12 L13 L14 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-45 0.14 / 3.6 0.43 / 11 1.30 / 33 2.16 / 55 2.20 / 56 0.31 / 7.9 0.08 / 1.9 1.43 / 36.3 0.16 / 4 VADMI-70 0.56 / 14.2 0.43 / 11 1.77 / 45 2.64 / 67 3.00 / 76.1 0.37 / 9.4 0.08 / 1.9 2.11 / 53.7 0.18 / 4.5 32 (Ref. 2.4/12-3) (97/98) Subject to change pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VADMI-... Type VADMI-95 Type VADMI-140 Type VADMI-200 Type VADMI-300 1 Supply Port 2 Vacuum Connection 3 Manual Override 4 Mounting Thread 5 Mounting Hole 7 Suitable for Socket Type KMEB-... and MSSD-EB Type B1 B2 B3 D1 D2 D3 D4 H1 H2 in / mm in / mm in / mm in / mm in / mm in / mm VADMI-95 0.71 / 18 0.53 / 13.4 0.71 / 18 G 1/8 G 1/8 0.16 / 4.2 M3 3.91 / 99.4 2.73 / 69.4 VADMI-140 0.87 / 22 0.65 / 16.6 0.71 / 18 G 1/4 G 1/8 0.20 / 5.2 M3 4.46 / 113.4 3.28 / 83.4 VADMI-200 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.70 / 119.4 3.52 / 89.4 VADMI-300 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.70 / 119.4 3.52 / 89.4 Type H3 H4 H5 H6 H7 L1 L2 L4 L5 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-95 1.92 / 48.9 1.00 / 25.5 0.92 / 23.3 1.30 / 33 0.71 / 18 2.91 / 73.8 2.40 / 61 1.70 / 43.3 0.34 / 8.7 VADMI-140 2.42 / 61.4 1.63 / 41.4 1.63 / 41.4 1.42 / 36 0.69 / 17.5 3.81 / 96.8 3.31 / 84 1.02 / 26 0.49 / 12.5 VADMI-200 2.66 / 67.7 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.75 / 19 3.81 / 96.8 3.31 / 84 1.02 / 26 0.49 / 12.5 VADMI-300 2.66 / 67.7 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.75 / 19 5.24 / 133.2 4.74 / 120.4 1.02 / 26 0.49 / 12.5 Type L6 L7 L8 L9 L10 L11 L12 L13 L14 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-95 0.52 / 13.2 0.22 / 5.7 1.95 / 49.5 2.40 / 61 3.10 / 78.8 0.37 / 9.5 0.09 / 2.3 2.16 / 55 0.18 / 4.5 VADMI-140 1.12 / 28.5 0.22 / 5.7 1.95 / 49.5 2.40 / 61 3.81 / 96.8 0.54 / 13.8 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADMI-200 1.12 / 28.5 0.22 / 5.7 1.95 / 49.5 2.40 / 61 4.01 / 101.8 0.49 / 12.5 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADMI-300 1.12 / 28.5 0.22 / 5.7 1.95 / 49.5 2.40 / 61 5.41 / 137.4 0.49 / 12.5 0.09 / 2.3 4.56 / 115.8 0.20 / 5 33 Subject to change (Ref. 2.4/12-3) (97/98) pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VADMI-... Type VADMI-45-P/N Type VADMI-70-P/N Type VADMI-45-LS-P Type VADMI-70-LS-P 1 Supply Port 2 Vacuum Connection 3 Manual Override 4 Mounting Thread 5 Mounting Hole 7 Suitable for Socket Type KMYZ-... 8 Connection for Socket Type SIM-... Type B1 B2 B3 D1 D2 D3 D4 H1 H2 H3 in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-45-P/N 0.39 / 10 0.24 / 6.2 0.39 / 10 M5 M5 0.13 / 3.2 M2 3.08 / 78.2 2.29 / 58.2 1.61 / 40.8 VADMI-70-P/N 0.59 / 15 0.44 / 11.2 0.59 / 15 G 1/8 M5 0.13 / 3.2 M2 3.50 / 88.9 2.54 / 64.4 1.85 / 47 VADMI-45-LS-P 0.39 / 10 0.24 / 6.2 0.39 / 10 M5 M5 0.13 / 3.2 M2 3.08 / 78.2 2.29 / 58.2 1.61 / 40.8 VADMI-70-LS-P 0.59 / 15 0.44 / 11.2 0.59 / 15 G 1/8 M5 0.13 / 3.2 M2 3.50 / 88.9 2.54 / 64.4 1.85 / 47 Type H4 H5 H6 H7 L1 L2 L3 L4 L5 L6 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-45-P/N 0.94 / 23.8 0.94 / 23.8 1.71 / 43.4 0.71 / 18 2.64 / 67 1.61 / 41 0.94 / 24 1.32 / 33.6 0.98 / 25 0.14 / 3.6 VADMI-70-P/N 1.04 / 26.5 0.92 / 23.5 1.92 / 48.8 0.71 / 18 3.32 / 84.3 2.30 / 58.3 0.94 / 24 1.59 / 40.4 0.83 / 21 0.56 / 14.2 VADMI-45-LS-P 0.94 / 23.8 0.94 / 23.8 1.71 / 43.4 0.71 / 18 2.81 / 71.4 1.61 / 41 1.12 / 28.4 1.32 / 33.6 0.98 / 25 0.14 / 3.6 VADMI-70-LS-P 1.04 / 26.5 0.92 / 23.5 1.92 / 48.8 0.71 / 18 3.49 / 88.7 2.30 / 58.3 1.12 / 28.4 1.59 / 40.4 0.83 / 21 0.56 / 14.2 Type L7 L8 L9 L10 L11 L12 L13 L14 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-45-P/N 0.43 / 11 1.30 / 33 2.16 / 55 2.20 / 56 0.31 / 7.9 0.08 / 1.9 1.43 / 36.3 0.16 / 4 VADMI-70-P/N 0.43 / 11 1.77 / 45 2.64 / 67 3.00 / 76.1 0.37 / 9.4 0.08 / 1.9 2.11 / 53.7 0.18 / 4.5 VADMI-45-LS-P 0.43 / 11 1.30 / 33 2.16 / 55 2.20 / 56 0.31 / 7.9 0.08 / 1.9 1.43 / 36.3 0.16 / 4 VADMI-70-LS-P 0.43 / 11 1.77 / 45 2.64 / 67 3.00 / 76.1 0.37 / 9.4 0.08 / 1.9 2.11 / 53.7 0.18 / 4.5 34 (Ref. 2.4/12-4) (97/98) Subject to change pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VADMI-… Type VADMI-95-P/N VADMI-140-P/N VADMI-200-P/N VADMI-300-P/N VADMI-95-LS-P VADMI-140-LS-P VADMI-200-LS-P VADMI-300-LS-P 1 Supply Port 2 Vacuum Connection 3 Manual Override 4 Mounting Thread 5 Mounting Hole 7 Suitable for Socket Type KMEB-... and MSSD-EB 8 Connection for Socket Type SIM-... Type B1 B2 B3 D1 D2 D3 D4 H1 H2 H3 in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-95-P/N 0.71 / 18 0.53 / 13.4 0.71 / 18 G 1/8 G 1/8 0.16 / 4.2 M3 3.91 / 99.4 2.73 / 69.4 1.92 / 48.9 VADMI-140-P/N 0.87 / 22 0.65 / 16.6 0.71 / 18 G 1/4 G 1/8 0.20 / 5.2 M3 4.46 / 113.4 3.28 / 83.4 2.42 / 61.4 VADMI-200-P/N 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.70 / 119.4 3.52 / 89.4 2.66 / 67.7 VADMI-300-P/N 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.70 / 119.4 3.52 / 89.4 2.66 / 67.7 VADMI-95-LS-P 0.71 / 18 0.53 / 13.4 0.71 / 18 G 1/8 G 1/8 0.16 / 4.2 M3 3.91 / 99.4 2.73 / 69.4 1.92 / 48.9 VADMI-140-LS-P 0.87 / 22 0.65 / 16.6 0.71 / 18 G 1/4 G 1/8 0.20 / 5.2 M3 4.46 / 113.4 3.28 / 83.4 2.42 / 61.4 VADMI-200-LS-P 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.70 / 119.4 3.52 / 89.4 2.66 / 67.7 VADMI-300-LS-P 0.87 / 22 0.65 / 16.6 0.71 / 18 G 3/8 G 1/4 0.20 / 5.2 M3 4.70 / 119.4 3.52 / 89.4 2.66 / 67.7 Type H4 H5 H6 H7 L1 L2 L3 L4 L5 L6 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-95-P/N 1.00 / 25.5 0.92 / 23.3 1.30 / 33 0.71 / 18 3.42 / 87 2.40 / 61 0.94 / 24 1.70 / 43.3 0.34 / 8.7 0.52 / 13.2 VADMI-140-P/N 1.63 / 41.4 1.63 / 41.4 1.42 / 36 0.69 / 17.5 4.33 / 110 3.31 / 84 0.94 / 24 1.02 / 26 0.49 / 12.5 1.12 / 28.5 VADMI-200-P/N 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.75 / 19 4.33 / 110 3.31 / 84 0.94 / 24 1.02 / 26 0.49 / 12.5 1.12 / 28.5 VADMI-300-P/N 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.75 / 19 5.76 / 146.4 4.74 / 120.4 0.94 / 24 1.02 / 26 0.49 / 12.5 1.12 / 28.5 VADMI-95-LS-P 1.00 / 25.5 0.92 / 23.3 1.30 / 33 0.71 / 18 3.60 / 91.4 2.40 / 61 1.12 / 28.4 1.70 / 43.3 0.34 / 8.7 0.52 / 13.2 VADMI-140-LS-P 1.63 / 41.4 1.63 / 41.4 1.42 / 36 0.69 / 17.5 4.50 / 114.4 3.31 / 84 1.12 / 28.4 1.02 / 26 0.49 / 12.5 1.12 / 28.5 VADMI-200-LS-P 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.75 / 19 4.50 / 114.4 3.31 / 84 1.12 / 28.4 1.02 / 26 0.49 / 12.5 1.12 / 28.5 VADMI-300-LS-P 1.63 / 41.4 1.63 / 41.4 1.58 / 40 0.71 / 18 5.94 / 150.8 4.74 / 120.4 1.12 / 28.4 1.02 / 26 0.49 / 12.5 1.12 / 28.5 Type L7 L8 L9 L10 L11 L12 L13 L14 in / mm in / mm in / mm in / mm in / mm in / mm in / mm in / mm VADMI-95-P/N 0.22 / 5.7 1.95 / 49.5 2.40 / 61 3.10 / 78.8 0.37 / 9.5 0.09 / 2.3 2.16 / 55 0.18 / 4.5 VADMI-140-P/N 0.22 / 5.7 1.95 / 49.5 2.40 / 61 3.81 / 96.8 0.54 / 13.8 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADMI-200-P/N 0.22 / 5.7 1.95 / 49.5 2.40 / 61 4.01 / 101.8 0.49 / 12.5 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADMI-300-P/N 0.22 / 5.7 1.95 / 49.5 2.40 / 61 5.41 / 137.4 0.49 / 12.5 0.09 / 2.3 4.56 / 115.8 0.20 / 5 VADMI-95-LS-P 0.22 / 5.7 1.95 / 49.5 2.40 / 61 3.10 / 78.8 0.37 / 9.5 0.09 / 2.3 2.16 / 55 0.18 / 4.5 VADMI-140-LS-P 0.22 / 5.7 1.95 / 49.5 2.40 / 61 3.81 / 96.8 0.54 / 13.8 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADMI-200-LS-P 0.22 / 5.7 1.95 / 49.5 2.40 / 61 4.01 / 101.8 0.49 / 12.5 0.09 / 2.3 3.13 / 79.4 0.20 / 5 VADMI-300-LS-P 0.22 / 5.7 1.95 / 49.5 2.40 / 61 5.41 / 137.4 0.49 / 12.5 0.09 / 2.3 4.56 / 115.8 0.20 / 5 35 Subject to change (Ref. 2.4/12-4) (97/98) pneuaire Solenoid-Actuated Vacuum Generators Performance Graphs, Type VADM and VADMI Air consumption as a function of operating pressure Operating Pressure p (bar) Operating Pressure p (bar) 3 456 7 8 3 456 7 8 2.5 70 24.7 700 VADM-95-... VADM-300-... 2.3 65 22.9 650 VADMI-95-... VADMI-300-... 2.2 60 21.2 600 2.1 55 19.4 550 1.8 50 17.6 500 1.6 45 15.9 450 VADM-70-... 1.4 VADMI-70-... 40 14.1 400 1.2 35 12.4 350 VADM-200-... 1.1 30 VADMI-200-... 10.6 300 0.9 25 8.8 250 0.7 VADM-45-... 20 7.1 200 VADM-140-... VADMI-45-... VADMI-140-... 0.5 15 5.3 150 0.4 10 3.5 100 0.2 5 1.8 50 0 0 0 0 45 60 75 90 105 120 45 60 75 90 105 120 Operating Pressure p (psi) Operating Pressure p (psi) Vacuum as a function of operating pressure Noise level as a function of operating pressure Operating Pressure p (bar) Operating Pressure p (bar) 01 2 3 4 5 6 7 8 27 . VADM-300-... VADMI-300-... 24 80 . VADM-200-... VADMI-200-... 21 . VADM-140-... 18 . 70 VADMI-140-... VADM-95-... 15 . VADMI-95-... 12 . 60 VADM-70-... 9 . VADMI-70-... VADM-45-... 6 . 50 VADMI-45-... 3 . 0 40 0 15 30 45 60 75 90 105 120 0 15 30 45 60 75 90 105 120 Operating Pressure p (psi) Operating Pressure p (psi) Efficiency as a function of vacuum at rated pressure The degree of efficiency is a criterion for making an objective comparison between vacuum generators of very different Vacuum ΔP (bar) u designs (single stage or multistage). -0.2 -0.4 -0.6 -0.8 0.9 0.8 1 η (Δp ) = u Operating t (Δp ) · Q 0.7 u pressure, 1 + p = 6 bar V · 60 s / min 0.6 0.5 η (Δp ) Degree of efficiency of vacuum generator relative to u 0.4 vacuum t(Δp ) Evacuation Time (s) 0.3 u 0.2 VADM-... Q Air consumption (l/min) VADMI-... V Volume to be evacuated standard volume (I) 0.1 0 612 18 24 Vacuum ΔP (in Hg) u 36 (Ref. 2.4/12-5) (97/98) Subject to change pneuaire Vacuum ΔP (in Hg) Air Consumption Q (SCFM) Efficiency η u Vacuum ΔP (bar) u Air Consumption Q (l/min) Noise Level L [dB(A)] Air Consumption Q (SCFM) Air Consumption Q (l/min) Solenoid-Actuated Vacuum Generators Performance Graphs, Type VADM and VADMI Evacuation time for a 1 liter volume with an operating pressure of 90 psi / 6 bar Vacuum ∆ P (bar) Vacuum ∆ P (bar) u u -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 30 6 VADM-95-... VADM-45-... VADMI-95-... 25 5 VADMI-45-... 20 4 VADM-140-... 15 3 VADMI-140-... VADM-70-... 10 VADMI-70-... 2 5 1 0 0 6 9 12 15182124 6 9 12 15 18 21 24 Vacuum ∆ P (in Hg) Vacuum ∆ P (in Hg) u u Vacuum ∆ P (bar) u -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 2 VADM-200-... VADMI-200-... 1 VADM-300-... VADMI-300-... 0 6 9 12 15 18 21 24 Vacuum ∆ P (in Hg) u Sound pressure level as a function of operating pressure (in gripped mode) Noise level as a function of operating pressure Operating Pressure p (bar) Operating pressure p (bar) 01 2 3 4 5 6 7 8 123 4 56 78 VADM-300-... 100 VADMI-300-... VADM-45-... 1 80 VADMI-45-... 90 VADM-200-... 6 VADMI-200-... VADM-70-... 2 80 VADMI-70-... 5 VADM-140-... VADM-95-... 70 VADMI-140-... 70 3 VADMI-95-... 4 3 1 VADM-95-... VADM-140-... 60 VADMI-95-... 4 VADMI-140-... 60 50 VADM-200-... 5 VADMI-200-... 2 VADM-70-... VADMI-70-... 40 VADM-300-... 6 VADM-45-... VADMI-300-... 50 VADMI-45-... 30 15 30 45 60 75 90 105 120 Operating pressure p (psi) 40 0 15 30 45 60 75 90 105 120 Operating Pressure p (psi) Air supply time for 1 liter volume with operating pressure of 90 psi / 6 bar Suction flow rate as a function of vacuum level Type With Without Max. Flow Rate Vacuum ∆ P (bar) u 0 -0.2 -0.4 -0.6 -0.8 -1 Ejector Ejector of Ejector 6.4 180 Pulses Pulses Pulse Operating 5.6 160 scfm / l/min pressure, p = 6 bar VADM-45-.. 5.9 s 4.9 140 VADMI-45-.. 1.9 s 0.68 / 19.2 6 4.2 120 VADM-70-.. 2.2 s VADM-45-... 1 VADMI-45-... 3.5 100 VADMI-70-.. 0.59 s 2.4 / 68 VADM-70-... 5 2 VADM-95-.. 1.18 s VADMI-70-... 2.8 80 VADM-95-... VADMI-95-.. 0.24 s 4.8 / 135 3 VADMI-95-... 2.1 60 VADM-140-.. 0.69 s VADM-140-... 4 4 VADMI-140-... VADMI-140-.. 0.19 s 7.1 / 200 1.4 40 3 VADM-200-... 5 VADM-200-.. 0.29 s VADMI-200-... 0.7 20 2 VADMI-200-.. 0.15 s 6.2 / 175 VADM-300-... 1 6 VADMI-300-... 0 0 VADM-300-.. 0.26 s 0 612 18 24 30 VADMI-300-.. 0.2 s 5.6 / 160 Vacuum ∆ P (in Hg) u 37 Subject to change (Ref. 2.4/12-6) (97/98) pneuaire Evacuation Time t (s) Noise Level L [dB(A)] Evacuation Time t (s) Suction Flow Rate (SCFM) Suction Flow Rate (l/min) Acoustic Power Level LWA [dB(A)] Evacuation Time t (s) Solenoid-Actuated Vacuum Generators Vacuum Switch Control Panel for Vacuum Switches Vacuum Switch For Type VADM-…-P VADM-…-N VADMI-…-P VADMI-…-N In a piezoresistive pressure switch, application of a vacuum results in the 1 Operating status display LED (yellow) 2 output of an electric signal. If the Switching point adjustment 3 Hysteresis adjustment predetermined threshold pressure is exceeded, an electrical signal at switch output A1 (normally open) or A2 (normally closed) is generated. Circuit diagrams for vacuum switches PNP-Switching output NPN-Switching output Accessories: Socket with cable for vacuum switch see pages 88-89 Type SIM-K-4-GD-… Type SIM-K-4-WD-… Type SIM-M8-4GD-… Type SIM-M8-4WD-… Pin-Allocation BN = brown 1 = Positive 2 = Normally closed contact (NC) WH = white BK = black 3 = Negative 4 = Normally open contact (NO) BU = blue R = Load L Vacuum Switch 381016 VADM-...-P (PNP) 381017 VADM-...-N (NPN) Design Piezoresistive vacuum switch with adjustable switching point and adjustable hysteresis Pressure Range 0 to 28.4 in Hg / 0 to -0.95 bar Overload Pressure max. 120 psi / 8 bar for t < 1 min Operating Voltage 10 to 30 VDC, Nominal Operating Voltage 24 VDC Voltage Drop at Switching Output 1.2 V Switching Output Current 130 mA Input Current Consumption max. 25 mA Electrical Connection Polarity protected Switching Point Adjustable 0 psi to 26.9 in Hg / 0 to -0.9 bar Impact of Temperature on Switching Point ≤ ± 0.075 psi / 10 K / ≤ ± 5 mbar / 10 K Hysteresis Adjustable 0.75 to 7.5 psi / 0.05 to 0.5 bar Time Delay max. 5 ms Type of Protection IP 65 Optical Display A yellow LED illuminates when the adjusted pressure threshold is exceeded and the output is switched Connection Socket with cable Type SIM-... 38 (Ref. 2.4/12-7) (97/98) Subject to change pneuaire Solenoid-Actuated Vacuum Generators With Integral Silencer and Manual Override, Type VAD-M..-(I)-… Type VAD-M..-... Type VAD-M..-I-... Solenoid-Actuated Vacuum Generator with integral silencer and manual override Type VAD-M..-... 1(P) 3(R) 2(V) with ejector pulse, integral silencer and manual override Type VAD-M..-I-... A B 1(P) 3(R) With these vacuum generators, the compressed air supply is controlled via an integral solenoid valve or valves. 2(V) When power is applied to the solenoid, the valve shifts and compressed air Ordering Information, see pages 8-10 flows from the supply port 1(P), through nozzle, and out port 3(R). As the air passes through the nozzle, the Venturi principle creates vacuum at the suction Accessories: port 2(V). Suction cups can be screwed into the suction port 2(V). When the Sockets with cables solenoid is de-energized, the vacuum at suction port 2(V) stops. for Type VAD-MZB-… and VAD-MYB-… 34997 KMYZ-2-24-2.5-LED, cable 2.5 m VAD-M..-I-... vacuum generators have two control valves to allow for fast 34998 KMYZ-2-24-5-LED, cable 5 m release of parts. When the solenoid in valve “B” is energized, compressed air flows from the supply port 1(P) and out 3(R) creating a vacuum at suction port for Type VAD-ME-… 2(V). When the “B” solenoid is de-energized and the “A” solenoid is energized, 30943 KME-1-24-2.5-LED, cable 2.5 m the vacuum stops and the compressed air is redirected to 2(V), quickly releasing 30945 KME-1-24-5-LED, cable 5 m the part(s) being held. (Note: The solenoids should not be energized at the See pages 85-86 same time.) All VAD-M..-... vacuum generators have an integral silencer at the exhaust port 3(R) to muffle exhaust noise. Order Number Vacuum Generators 35552 35553 35554 35555 35556 Part Number/Type With One Control Valve VAD-MZB-M5 VAD-MYB-1/8 VAD-ME-1/8 VAD-ME-1/4 VAD-ME-3/8 Vacuum Generators/Ejectors 35529 35530 35531 35532 35533 With Two Control Valves VAD-MZB-I-M5 VAD-MYB-I-1/8 VAD-ME-I-1/8 VAD-ME-I-1/4 VAD-ME-I-3/8 Venturi Nozzle Diameter 0.02 in / 0.45 mm 0.03 in / 0.7 mm 0.04 in / 0.95 mm 0.06 in / 1.4 mm 0.08 in / 2 mm Medium Compressed air, filtered (40 µm), unlubricated Design Venturi principle, solenoid valve controlled Mounting Through holes in housing Connection Ports 1/2 M5 / M5 M5 / G 1/8 G 1/8 / G 1/8 G 1/8 / G 1/4 G 1/4 / G 3/8 Pressure Range 15 to 120 psi / 1 to 8 bar (Optimum operating pressure 75 to 105 psi / 5 to 7 bar) Air Consumption, Vacuum, Evacuation Time, See graphs on pages 42-43 Efficiency, Noise Level Switching Time 10 ms Ambient Temperature +32 to +104°F / 0 to +40°C Medium Temperature +32 to +104°F / 0 to +40°C Materials Housing: Anodized aluminum; Seals: Buna N Weight 0.070 lb / 0.176 lb / 0.276 lb / 0.463 lb / 0.529 lb / 0.032 kg 0.080 kg 0.125 kg 0.210 kg 0.240 kg 0.121 lb / 0.298 lb / 0.353 lb / 0.551 lb / 0.617 lb / 0.055 kg 0.135 kg 0.160 kg 0.250 kg 0.280 kg Solenoid Valve Operating Voltage 24 V Solenoid Power Consumption, Vacuum/Release 1.4 / 1.4 W 1.4 / 1.4 W 2.5 / 2.5 W 1.5 / 2.5 W 1.5 / 2.5 W Duty Cycle 100% Type of Protection with Socket IP 65 39 Subject to change (Ref. 2.4/15-1) (97/98) pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VAD-M..-... Type VAD-MZB-M5 Type VAD-ME-... VAD-MYB-1/8 Dimensions a 0.07 in / 1.9 mm 1 Socket Type KMYZ-2-24-... with two conductor cables 8.2 ft (2.5 m) or 2 16.4 ft (5 m) long, diameter (22 gauge) 3.6 mm (2 x 0.35 mm ) 2 Socket Type KME-1-24-... with two conductor cables 8.2 ft (2.5 m) or 2 16.4 ft (5 m) long, diameter (18 gauge) 5.6 mm (2 x 0.75 mm ) 3 Mounting thread 4 Manual override 5 Yellow LED Type B D1 D2 D3 D4 D5 H1 in / mm in / mm in / mm in / mm VAD-MZB-M5 0.39 / 10 M5 M3 M5 0.13 / 3.2 — 2.16 / 55 VAD-MYB-1/8 0.59 / 15 G 1/8 M4 M5 0.16 / 4.2 — 2.46 / 62.5 VAD-ME-1/8 0.71 / 18 G 1/8 M4 G 1/8 0.16 / 4.2 0.13 / 3.2 3.66 / 93 VAD-ME-1/4 0.87 / 22 G 1/4 M4 G 1/8 0.16 / 4.2 0.16 / 4.2 4.20 / 106.8 VAD-ME-3/8 0.87 / 22 G 3/8 M5 G 1/4 0.20 / 5.2 0.20 / 5.2 4.45 / 113.1 Type H2 H3 H4 H5 H6 L1 L2 in / mm in / mm in / mm in / mm in / mm in / mm in / mm VAD-MZB-M5 0.39 / 9.8 0.20 / 5 0.57 / 14.5 0.98 / 25 1.77 / 45 1.91 / 48.5 1.32 / 33.5 VAD-MYB-1/8 0.50 / 12.7 0.28 / 7 0.87 / 22 1.14 / 29 2.20 / 56 2.65 / 67.2 1.71 / 43.5 VAD-ME-1/8 0.56 / 14.2 0.26 / 6.5 0.79 / 20 1.42 / 36 2.52 / 64 2.99 / 76 2.40 / 61 VAD-ME-1/4 0.34 / 8.7 0.35 / 9 1.30 / 33 1.97 / 50 3.06 / 77.8 3.80 / 96.6 2.40 / 61 VAD-ME-3/8 0.43 / 11 0.39 / 10 1.54 / 39 2.20 / 56 3.31 / 84.1 4.01 / 101.8 2.40 / 61 Type L3 L4 L5 L6 L7 L8 in / mm in / mm in / mm in / mm in / mm in / mm VAD-MZB-M5 0.43 / 11 0.26 / 6.5 1.06 / 27 1.12 / 28.5 1.00 / 25.5 — VAD-MYB-1/8 0.55 / 14 0.22 / 5.5 1.32 / 33.5 1.36 / 34.6 1.26 / 32 — VAD-ME-1/8 1.06 / 27 0.75 / 19 1.20 / 30.5 1.89 / 48 1.28 / 32.5 2.28 / 58 VAD-ME-1/4 1.14 / 29 0.89 / 22.5 0.85 / 21.5 1.89 / 48 1.46 / 37 2.28 / 58 VAD-ME-3/8 1.26 / 32 0.92 / 23.5 0.85 / 21.5 1.89 / 48 1.56 / 39.5 2.28 / 58 40 (Ref. 2.4/15-2) (97/98) Subject to change pneuaire Solenoid-Actuated Vacuum Generators Dimensions, Type VAD-M..-I-… Type VAD-MZB-I-M5 Type VAD-ME-I-... VAD-MYB-I-1/8 1 Socket Type KMYZ-2-24-... with two conductor cables 8.2 ft (2.5 m) or 2 16.4 ft (5 m) long, diameter (22 gauge) 3.6 mm (2 x 0.35 mm ) 2 Socket Type KME-1-24-... with two conductor cables 8.2 ft (2.5 m) or 2 16.4 ft (5 m) long, diameter (18 gauge) 5.6 mm (2 x 0.75 mm ) 3 Mounting thread 4 Manual override 5 Yellow LED B D1D2 D3 D4 D5H1 Type in / mm in / mm in / mm in / mm VAD-MZB-I-M5 0.39 / 10 M5 M3 M5 0.13 / 3.2 — 2.28 / 58 VAD-MYB-I-1/8 0.59 / 15 G 1/8 M4 M5 0.16 / 4.2 — 2.66 / 67.5 VAD-ME-I-1/8 0.71 / 18 G 1/8 M4 G 1/8 0.16 / 4.2 0.13 / 3.2 3.66 / 93 VAD-ME-I-1/4 0.87 / 22 G 1/4 M4 G 1/8 0.16 / 4.2 0.16 / 4.2 4.20 / 106.8 VAD-ME-I-3/8 0.87 / 22 G 3/8 M5 G 1/4 0.20 / 5.2 0.20 / 5.2 4.45 / 113.1 Type H2 H3 H4 H5 H6 L1 L2 in / mm in / mm in / mm in / mm in / mm in / mm in / mm VAD-MZB-I-M5 0.39 / 9.8 0.20 / 5 0.57 / 14.5 1.10 / 28 1.89 / 48 2.32 / 59 2.16 / 55 VAD-MYB-I-1/8 0.50 / 12.7 0.28 / 7 0.87 / 22 1.34 / 34 2.30 / 58.5 3.16 / 80.2 2.64 / 67 VAD-ME-I-1/8 0.56 / 14.2 0.26 / 6.5 0.79 / 20 1.42 / 36 2.52 / 64 2.99 / 76 2.40 / 61 VAD-ME-I-1/4 0.34 / 8.7 0.35 / 9 1.30 / 33 1.97 / 50 3.06 / 77.8 3.80 / 96.6 2.40 / 61 VAD-ME-I-3/8 0.43 / 11 0.39 / 10 1.54 / 39 2.20 / 56 3.31 / 84 4.01 / 101.8 2.40 / 61 Type L3 L4 L5 L6 L7 in / mm in / mm in / mm in / mm in / mm VAD-MZB-I-M5 0.79 / 20 0.26 / 6.5 1.06 / 27 2.28 / 58 1.42 / 36 VAD-MYB-I-1/8 1.02 / 26 0.22 / 5.5 1.32 / 33.5 2.76 / 70 1.77 / 45 VAD-ME-I-1/8 1.06 / 27 0.75 / 19 1.20 / 30.5 3.78 / 96 1.28 / 32.5 VAD-ME-I-1/4 1.14 / 29 0.89 / 22.5 0.85 / 21.5 3.78 / 96 1.46 / 37 VAD-ME-I-3/8 1.26 / 32 0.92 / 23.5 0.85 / 21.5 3.78 / 96 1.56 / 39.5 41 Subject to change (Ref. 2.4/15-2) (97/98) pneuaire Solenoid-Actuated Vacuum Generators Performance Graphs, Type VAD-M..-... Air consumption as a function of operating pressure Vacuum as a function of operating pressure Noise level as a function of operating pressure (without suction flow) 1 VAD-MZB-M5 1 VAD-ME-3/8 VAD-MYB-1/8 2 VAD-ME-1/8 VAD-ME-1/4 3 VAD-M3-1/4 VAD-ME-3/8 4 VAD-MYB 2 VAD-ME-1/8 5 VAD-MZB Efficiency as a function of vacuum at rated pressure The degree of efficiency is a criterion for making an objective comparison between vacuum generators of very different designs (single stage or multistage). 1 η (Δp ) = u t (Δp ) · Q u 1 + V · 60 s / min η (Δp ) Degree of efficiency of vacuum generator relative to u vacuum t(Δp ) Evacuation Time (s) u 1 VAD-ME-... Q Air consumption (l/min) 2 VAD-MYB-... 3 VAD-MZB-... V Volume to be evacuated standard volume (I) 42 (Ref. 2.4/15-3) (97/98) Subject to change pneuaire Solenoid-Actuated Vacuum Generators Performance Graphs, Type VAD-M..-… Evacuation time for a two liter volume with an operating pressure of 90 psi (6 bar) Evacuation volume as a function of the number of suction cups (VAS) and tubing (PU) PU-... = Festo polyurethane tubing 43 Subject to change (Ref. 2.4/15-4) (97/98) pneuaire All-Pneumatic Vacuum Generators Features and Benefits All-Pneumatic Vacuum Generators Types VAD-... with Ejector Pulse, Type VAK-... Type VAD-... ll No moving parts for virtually maintenance free operation ll Vacuum Ports: M5 to G 3/8 Type VAK-... ll Supply Ports: M5 to G 3/8 Built-in Reservoir ll Exhaust Ports: (Type VAK) for M5 to G 3/8 Rapid Part Ejection ll Lightweight corrosion resistant Aluminum housing ll Pressure Range: Vacuum via 22 to 150 psi / 1.5 to 10 bar Venturi Principle Connection for Pages 45-47 External Reservoir Supply Port Exhaust Port Vacuum Port Shown with Suction Cup, (Ordered Separately) 44 Subject to change pneuaire All-Pneumatic Vacuum Generators Vacuum Generators, Type VAD-…, VAK-… VAD-1/4 All-Pneumatic Vacuum Generators Type VAD-... PR U Type VAD-1/4 VAD-3/8 VAD-M5 with ejector pulse VAD-1/8 Type VAK-1/4 R P U Type VAK-1/4 VAK-1/4 Festo vacuum generators utilize a Venturi principle to generate vacuum without Ordering Information, see pages 8-10 the use of expensive vacuum pumps. The vacuum is achieved using shop air (filtered, lubricated or non-lubricated) obtained directly from the compressed air Accessories: network. Vacuum Suction Cups and Adapters, see pages 48-65 The design of the system assures minimal air consumption. Silencers can be connected at port R to muffle exhaust noise. Vacuum generators, Type VAK, Silencers, see pages 90-92 feature ejector pulse capability for fast ejection. When the intake is closed, air stored in the built-in air chamber surges through port U, ejecting the object being held. Supply air can be controlled by an additional 2- or 3-way, 2-position directional control valve to save air. Order Number Part No./Type 19293 VAD-M5 14015 VAD-1/8 9394 VAD-1/4 19294 VAD-3/8 6890 VAK-1/4 Nozzle Diameter Venturi Nozzle 0.02 in / 0.5 mm 0.03 in / 0.8 mm 0.04 in / 1.1 mm 0.06 in / 1.5 mm 0.04 in / 1.1 mm Receiver Nozzle 0.05 in / 1.3 mm 0.08 in / 2.1 mm 0.11 in / 2.8 mm 0.16 in / 4.0 mm 0.11 in / 2.8 mm Medium Compressed air Design Venturi principle Mounting Through holes in housing M6 threading Connection M5 G 1/8 G 1/4 G 3/8 G 1/4 Pressure Range 22 to 150 psi / 1.5 to 10 bar Vacuum Level, Air Consumption, Noise Level See graphs on page 47 3 Air Reservoir Volume 1.95 cu in / 32 cm Temperature Range -4 to +176°F / -20 to +80°C Materials Housing: Anodized aluminum Weight 0.031 lb / 0.086 lb / 0.201 lb / 0.340 lb / 0.580 lb / 0.014 kg 0.039 kg 0.091 kg 0.154 kg 0.263 kg 45 Subject to change (Ref. 2.4/16-1) (97/98) pneuaire All-Pneumatic Vacuum Generators Dimensions, Type VAD-…, VAK-… Type VAD-M5 Type VAD-1/8 Type VAD-1/4 a c h G 1/4 g f a b d e Type VAD-3/8 Type VAK-1/4 pp r oo ll mm nn ii jj kk Dimensions a 1.18 in / 30 mm v 0.71 in / 18 mm b 0.83 in / 21 mm w 0.43 in / 11 mm c 0.79 in / 20 mm x 0.60 in / 15.3 mm d 0.22 in / 5.5 mm y 0.80 in / 20.4 mm e 1.89 in / 48 mm z 1.81 in / 46 mm f 2.44 in / 62 mm aa 0.51 in / 13 mm P = Supply g 0.98 in / 25 mm bb 0.29 in / 7.3 mm U = Vacuum Connection h 0.35 in / 9 mm cc 0.39 in / 10 mm R = Exhaust i 0.20 in / 5 mm dd 0.53 in / 13.5 mm j 1.58 in / 40 mm ee 0.13 in / 3.2 mm k 2.28 in / 58 mm ff 0.18 in / 4.7 mm 1 Port U l 1.42 in / 36 mm gg 0.42 in / 10.8 mm 2 Port for additional ejector pulse air volume m 2.76 in / 70 mm hh 0.65 in / 16.5 mm n 0.87 in / 22 mm ii 1.42 in / 36 mm o 0.28 in / 7 mm jj 1.02 in / 26 mm p 0.18 in / 4.5 mm kk 1.14 in / 29 mm q 1.97 in / 50 mm ll 0.24 in / 6.2 mm r 0.91 in / 23 mm mm 2.11 in / 53.5 mm s 0.67 in / 17 mm nn 2.74 in / 69.5 mm t 1.34 in / 34 mm oo 0.37 in / 9.5 mm u 0.24 in / 6 mm pp 1.46 in / 37 mm 46 (Ref. 2.4/16-2) (97/98) Subject to change pneuaire All-Pneumatic Vacuum Generators Performance Graphs, Type VAD-…, VAK-… Air consumption as a function of operating pressure Vacuum flow as a function of operating pressure Vacuum as a function of operating pressure 1 VAD-3/8 2 VAD-1/4 VAK-1/4 3 VAD-1/8 4 VAD-M5 Noise level as a function of operating pressure Suction flow rate as a function of vacuum level 1 VAD-3/8* 2 VAD-3/8† 3 VAD-1/4* VAK-1/4* 4 VAD-1/4† VAK-1/4† 1 VAD-3/8 5 VAD-M5† 2 VAD-1/4 6 VAD-1/8* 3 VAD-1/8 7 VAD-M5* * = without silencer 4 VAD-M5 8 VAD-1/8† † = with silencer 47 Subject to change (Ref. 2.4/16-3) (97/98) pneuaire
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the VADMI-200-P have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods