Details

Part Number ESS150-24
Manufacturer ETA-USA
Category AC/DC SWITCHING POWER SUPPLIES
Price Request Quote
Lead Time Request Quote

Description

ETA-USA ESS150-24 Power Supply - 150W, AC/DC Switching PS

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Elite.Parts is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need an ESS150-24? We can help you find it at a competitive price!

Specifications

Cooling Convection
Dimension (WxLXH) 37.5mm x 164.5mm x 81.5mm
Driving Indicator Power Source on LED indication; Green
Humidity Operating:20~90% RH; Storage:10~95% RH [non-condensing]
Isolation Resistance Primary-Secondary-Frame Ground 100MO(minimum) by DC500V insulation tester
Leakage current 500µA
Line Conducted Noise [EMI] Built to meet FCC-B, VCCI-B, CISPR22-B, EN55022-B
Line Harmonic Distortion/Current IEC61000-3-2 Compliant
MTBF >150,000 hours
Over current Protection Operate at 105% min of rated current, automatic return
Over voltage Protection Input reentry at shutdown
Parallel Operation Not Available (N+1 Operation is Applicable by Diode-OR)
Remote Control Applicable by Option(External signal input is required)
Remote Sense Available
Safety UL60950-1 1st ed., CAN/CSA C22.2 No.60950-1-03-Approved; UL508 17th ed., CAN/CSA C22.2 No.107.1-01-Approved; EN60950-1:2001+A11:2004-Approved; CE Marking:EN60950-1:2001+A11:2004(LVD)-Declared
Series Operation Available
Shock 196 m/s2 on x,y,z axis
Temperature Operating:-10 to +71°C; Storage:-30 to +85°C
Vibration 5~10Hz:10mm double amplitude,10-55Hz:19.6m/s2,30 minute cycle each along X,Y,Z axes(non-operating)
Weight (typical) 600 g
Withstanding Voltage Primary-Secondary:AC3,000V for 1minute; Primary-Frame Ground:AC2,500V for 1minute; Secondary-Frame Ground:AC1,000V for 1minute; *Sensory Current: Secondary Frame Ground-(20[mA])/Others (10[mA])

Features

  • Can meet medical and appliance standards
  • Low leakage
  • Operating temp shows full load at 50°C (122° F), can operate at temperatures up to 71°C
  • Over-current protection
  • Over-voltage protection
  • Remote Sensing (sense line) available
  • Smaller than competitors by 15-20%

Datasheet

Download "ETA-USA=ESS150-24=datasheet1-1798546853.pdf" (1169 KiB)

Extracted Text

A AC C//D DC C S SW WIIT TC CH HIIN NG G P PO OW WE ER R SUPPLY SUPPLY S SIIN NG GL LE E C CH HA AN NN NE EL L O OU UT TP PU UT T 1 15 50 0 W WA AT TT TS S U UN NIIV VE ER RS SA AL L IIN NP PU UT T ESS150 SERIES General Description RoHS Features 1. Smaller than competitors by 15-20% 2. Operating temp shows full load at 50° C (122° F), can operate at temperatures up to 71°C 3. Five-year guarantee 4. Over-current protection 5. Over-voltage protection Application Broad needs 6. Remote Sensing (sense line) available Input Input Voltage: AC100~240V 7. Can meet medical and appliance Input Voltage Range: AC85~264V (DC110~350V) standards 8. Low leakage < 500µA 50/60Hz Input Frequency: Frequency Range: 47~440Hz Single Phase: Options Inrush Current: *1 14A at 100V; 28A at 200V Remote Control optional Remote sensing available DIN Rail available “-J” Molex connector option (except 3.3V/5V ) ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.eta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com Models Output Unit ESS150-3.3 ESS150-05 ESS150-12 ESS150-15 ESS150-24 ESS150-36 ESS150-48 Characteristic Vdc 3.3 5.0 12 15 24 36 48 Output Voltage A 30 30 13 10 6.5 4.3 3.3 Output Current V 2.97~3.63 4.50~5.50 10.8~13.2 13.5~16.5 21.6~26.4 32.4~39.6 43.2~52.8 Voltage Adjust Range mVpp 120 120 150 150 150 250 250 Ripple &Noise(max) mS Rise time 30 typ. mS Hold up time 30 max. Regulation mV 20 48 60 96 144 192 a. Line Regulation 20 [max] mV 40 100 120 150 240 240 b. Load Regulation 40 0 to 50 50 120 150 240 360 480 c. Temperature 50°C Coefficient -10 60 60 150 180 290 450 600 to 0°C mV 20 48 60 96 144 192 d. Drift(maximum) 20 % At AC100V 81%-86.5% Efficiency *1 At AC 200V 83%-89% 0.89-0.99 Power Factor *1 Note: If you would like to buy a wire harness with this power supply, you may either order the wire harness through Molex or directly through ETA-USA. Please observe the following table: ETA POWER INPUT HOUSING OUTPUT HOUSING ETA WIRE HARNESS # ; SUPPLY -MOLEX -MOLEX TERMINAL input/output ESS150-3.3J ESS150-05J ESS150-12J WH-ESS150-J; 40cm WIRE ESS150-15J 0010-63-3044- (5199-04) 0009-50-1063-(5196-06) 5194PBT(L) HARNESS ESS150-24J ESS150-36J ESS150-48J ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.eta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com Environmental Specification Operating Temperature*3 -10 to +71 °C Operating Humidity 20~90% RH Storage Temperature -30 to +85 °C Storage Humidity 10~95% RH [non-condensing] Withstanding Voltage Primary-Secondary AC3,000V for 1minute Primary-Frame Ground AC2,500V for 1minute Secondary-Frame Ground AC1,000V for 1minute *Sensory Current: Secondary Frame Ground (20[mA])/Others (10[mA]) Isolation Resistance Primary-Secondary-Frame Ground 100MΩ(minimum) by DC500V insulation tester 2 Vibration 5~10Hz:10mm double amplitude,10-55Hz:19.6m/s ,30 minute cycle each along X,Y,Z axes(non-operating) 2 Shock 196 m/s on x,y,z axis Cooling Convection Leakage current 500µA MTBF >150,000 hours Environmental Agencies Line Conducted Noise [EMI] Built to meet FCC-B, VCCI-B, CISPR22-B, EN55022-B Line Harmonic IEC61000-3-2 Compliant Distortion/Current Safety UL60950-1 1st ed., CAN/CSA C22.2 No.60950-1-03 Approved UL508 17th ed., CAN/CSA C22.2 No.107.1-01 Approved EN60950-1:2001+A11:2004 Approved CE Marking:EN60950-1:2001+A11:2004(LVD) Declared Function/Protection Over current Protection Operate at 105% min of rated current, automatic return Over voltage Protection Input reentry at shutdown Remote Sense Available Remote Control Applicable by Option(External signal input is required) Series Operation Available Parallel Operation Not Available (N+1 Operation is Applicable by Diode-OR) Driving Indicator Power Source on LED indication; Green Mechanical Dimension [mm] 37.5W × 164.5L × 81.5H Weight [g](typical) 600 Conditions: *1 Rated input and Rated output *2 at Output current quick change 25% to 75% *3 At 100% load (convection cooling) ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.eta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com Derating Curves ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.eta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com Efficiency Curves Mechanical Drawings ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.eta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com “–J” connector ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.eta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com

Related Products

None available

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Elite.Parts are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Elite.Parts is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.061 seconds.