10 WATT
AC-DC
CONVERTER
BJS-FWA Series
DUAL CHANNEL
Specifications Model
BJS**FWA-U
BJS22FWA-U BJS23FWA-U BJS24FWA-U BJS24FWA-B-U
10WATTS/2OUTPUTS
Input Characteristic
Input Voltage AC100-115V
Input Current 0.3A
Input Range AC85-132V
Input Frequency 50/60Hz
Input Frequency Range 47-440Hz
Phase Single
Inrush Current *1 20A(maximum) at AC100V
Efficiency [%] (typical) *2 77 78 73 74
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
Specifications Model
BJS**FWA-U
BJS22FWA-U BJS23FWA-U BJS24FWA-U BJS24FWA-B-U
10WATTS/2OUTPUTS
Output
Output Voltage [V] 12 12 15 15 5 12 12 5
Output Current [A] 0.6 0.3 0.4 0.3 1.2 0.3 0.7 0.3
Voltage Adjust Range not available
Voltage Tolerance [mVp-p](typical) +/-0.12 11.28-11/48 +/-0.15 14.1-15.6 +/-0.1 11.28-12.48 +/-0.12 4.7-5.2
Ripple and Noise [mVp-p](maximum) *3 220 220 250 250 150 220 220 150
Regulation
a.Statistic Line Regulation [mV](maximum) 96 120 40 96
b.Statistic Load Regulation [mV](maximum) 108 135 45 108
c.Temperature Coefficient *4 0.03%/℃
d.Drift[mV](maximum) *5 75 90 40 75
e.Dynamic Load Regulation [mV](typical) *6 +/-360 +/-450 +/-150 +/-360
f.Recovery Time *6 20mS(typical)
Rise up time 200mS(maximum) at 25℃ and rated input/output
Hold up time 20mS(typical) at 25℃ and rated input/output
Functions
Overcurrent Protection ≧ 110%
of Rated Output Current[A]
V1=Current Limiting with automatic recovery
≧
Overvoltage Protection 115%
of Rated Output Voltage[V]
zener diode clamping
Remote Sense not available
Remote On/Off not available
Power Fail Detection not available
Parallel/series Operation not available
Environmental
Operating Temperature -10 to +71℃ ( -10 to 50℃ at full load condition)
Operating Humidity 20 to 90%RH(non-condensing)
℃
Storage Temperature -20 to +85
Storage Humidity 10 to 85%RH(non-condensing)
Withstanding Voltage Primary-Secondary AC1,500V for 1minute
Primary-Frame Ground AC1,500V for 1minute
Secondary-Frame Ground AC500V for 1minute
Isolation Resistance Primary-Secondary-F rame Ground 50MΩ(minimum) by DC500V insulation tester
2
Vibration
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s ,20minutes' period for 60minutes each along X,Y,Z axes(non-operating)
2
Shock 196m/s
Cooling Convection
Leakage Current 55uA(typical) at 25℃ ,50Hz and AC100V input
Line Conducted Noise Built to meet FCC Part15-B Class B
Built to meet VCCI Class B
UL: UL1950
Safety
C-UL: CSA C22.2 No.950
Weight (typical) 35g
MTBF [H] 1,200,000
Switching Frequency[kHz](typical) 110kHz at rated input/output
90 to 600kHz at input voltage of AC85 to 132V with a load of 0 to 100%
Conditions:
*1at cold start
*2 measured by a bayonet probe at the end of a pair of 5cm long wires terminated with a 100uF electrolytic
capacitor and 0.1uF film capacitor in parallel at a 0 to 100MHz bandwidth
*3 when output current changed from 0mA to rated output current
*4 at -10 to +40℃
*5 for 7hour period after 1hour warm-up at 25℃ and rated input/output
*6 when output current changed from 25% to 75% of rated output current rapidly at rated input
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods