Elite.Parts chervon right Manufacturers chervon right E chervon right EST chervon right SIGA-SB4
About product Datasheet FAQ

EST SIGA-SB4

Image of EST SIGA-SB4

Description

EST SIGA-SB4 Smoke Detector Mounting Base. 4 Inch

Part Number

SIGA-SB4

Price

Request Quote

Manufacturer

EST

Lead Time

Request Quote

Category

PRODUCTS - S

Datasheet

pdf file

EST-SIGA-SB4-datasheet1-1474548249.pdf

380 KiB

Extracted Text

05-18-11 EST Catalog u Intelligent Initiating Intelligent Ionization Smoke Detector SIGA-IS S CHINA Application Notes Available Overview Fast Stable Communication - On-board intelligence means less EST’s Signature Series Model SIGA-IS Intelligent Ionization Smoke information needs to be sent between the detector and the loop Detector gathers analog information from its smoke sensing ele- controller. Other than regular supervisory polling response, the ment and converts it into digital signals. The detector’s on-board detector only needs to communicate with the loop controller when microprocessor measures and analyzes these signals. It compares it has something new to report. the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually eliminated. Standard Features The microprocessor in each detector provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Map- • Integral microprocessor ping, Stand-alone Operation and Fast, Stable Communication. • Non-volatile memory Self-diagnostics and History Log - Each Signature Series • Automatic device mapping detector constantly runs self-checks to provide important mainte- • Electronic addressing nance information. The results of the self-check are automatically updated and permanently stored in the detector’s non-volatile • Environmental compensation memory • Intelligent detector Automatic Device Mapping - The loop controller learns where • Wide 0.61% to 1.91%/ft. sensitivity range each device’s serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision • Twenty pre-alarm sensitivity values, set in 5% increments¹ of each device’s installed location to prevent a detector from being • Identification of dirty or defective detectors reinstalled (after cleaning etc.) in a different location from where it was originally. • Automatic day/night sensitivity adjustment Stand-alone Operation - A decentralized alarm decision by the • Twin RED/GREEN status LEDs detector is guaranteed. On-board intelligence permits the detector • Standard, relay, fault isolator, and audible mounting bases to operate in stand-alone mode. If loop controller CPU communi- • Designed and manufactured to ISO 9001 standards cations fail for more than four seconds, all devices on that circuit go into stand-alone mode. The circuit acts like a conventional Note: Some features described here may not be supported by all control systems. Check your control panel’s Installation and Operation Guide for details. alarm receiving circuit. Page 1 of 4 D A T A S H E E T 85001-0291 Not to be used for installation purposes. Issue 8 Typical Wiring 2 2 2 The detector mounting bases will accept #18 AWG (0.75mm ), #16 (1.0mm ), #14 AWG (1.5mm ) and #12 AWG (2.5mm²) wire sizes. 2 2 Note: Sizes #16 AWG (1.0mm ) and #18 AWG (0.75mm ) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, SIGA-SB, SIGA-SB4 Relay Detector Base, SIGA-RB, SIGA-RB4 Term Description Term Description 1 Normally-Open Remote LED 1 Not Used 2 DATA IN/OUT (+) 2 DATA IN/OUT (+) Max resistance 3 Common 3 Not Used per wire 4 DATA IN (-) 4 DATA IN (-) must not exceed 5 Not Used 4 Remote LED (-) 10 Ohms 6 Normally-Closed 5 Remote LED (+) 7 DATA OUT (-) 6 Not Used 7 DATA OUT (-) CONTACT RATING 1.0 Amp @ 30 VDC (Pilot Duty) DATA IN (-) DATA OUT (-) DATA OUT (+) DATA IN (+) To Next Device From Signature Controller or Previous Device Isolator Detector Base, SIGA-IB, SIGA-IB4 Audible Detector Base, SIGA-AB4G Term Description 1 Not Used Volume setting 2 DATA IN/OUT (+) Tone setting Default = High volume 3 DATA IN (-) Default =Temporal pattern Cut for low volume Cut for steady tone 4 Not Used 5 Not Used DATA- DATA- DATA+ SIG+ SIG- OUT IN IN/OUT 6 DATA OUT (-) 7 Not Used To configure output volume or tone, cut the circuit board as shown. 24 Vdc in - - 24 Vdc out From power supply or + + To next base or EOLrelay previous base - Data in - Data out From Signature controller or + + To next Signature device previous device Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes and to 4 inch square Testing & Maintenance electrical boxes, 1-1/2 inches (38 mm) deep. They mount to Euro- Each detector automatically identifies when it is dirty or defective pean BESA and 1-gang boxes with 60.3 mm fixing centers. and causes a “dirty detector” message. The detector’s sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report can be printed to satisfy NFPA sensitivity meas- urements which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detec- tor operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility The SIGA-IS detectors are compatible only with EST’s Signature Loop Controller. Page 2 of 4 D A T A S H E E T 85001-0291 Not to be used for installation purposes. Issue 8 Application Although ionization detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. Edwards recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. SIGA-HRS and SIGA-HFS Rate-of- SIGA-PHS SIGA-IPHS Test Fire SIGA-IS Ion SIGA-PS Photo Rise/ Fixed Temp. Photo Heat 3D Ion/Photo/Heat 4D Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum Smouldering Cotton very suitable optimum unsuitable optimum optimum Poly Urethane Foam very suitable very suitable suitable very suitable optimum n-Heptane optimum very suitable very suitable optimum optimum Liquid Fire without unsuitable unsuitable optimum very suitable very suitable Smoke Accessories All detector mounting bases have wiring terminals that are acces- Isolator Base SIGA-IB, SIGA-IB4 - This base includes a built-in sible from the “room-side” after mounting the base to the electrical line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the box. The bases mount to North American 1-gang boxes and to SIGA-LED Remote LED. 3½ inch or 4 inch octagon boxes, 1½ inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm The isolator operates as follows: fixing centers. The SIGA-SB4, SIGA-RB4, and SIGA-IB4 mount - a short on the line causes all isolators to open within 23 msec to North American 4 inch square electrical boxes in addition to - at 10 msec intervals, beginning on one side of the Class A the above boxes. They include the SIGA-TS4 Trim Skirt which is circuit nearest the loop controller, the isolators close to used to cover the “mounting ears” on the base. The SIGA-AB4G provide the next isolator down the line with power mounts to a 4” sqare box only. - if the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Remote LED SIGA-LED - The remote LED connects to the SIGA-AB4G SIGA-SB SIGA-IB SIGA-RB SIGA-LED SIGA-SB or SIGA-SB4 Standard Base only. It features a North Audible Base Standard Base Isolator Base Relay Base Remote LED American size 1-gang plastic faceplate with a white finish and red Standard Base SIGA-SB, SIGA-SB4 - This is the basic mount- alarm LED. ing base for Edwards Signature Series detectors. The SIGA-LED SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also Remote LED is supported by the Standard Base. be ordered separately to use with the other bases to help hide Relay Base SIGA-RB, SIGA-RB4 - This base includes a relay. surface imperfections not covered by the smaller bases. Normally open or closed operation is selected during installa- Warnings & Cautions tion. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The This detector will not operate without electrical power. As fires fre- relay’s position is supervised to avoid accidentally jarring it out of quently cause power interruption, we suggest you discuss further position.The SIGA-RB can be operated as a control relay if pro- safeguards with your fire protection specialist. grammed to do so at the control panel (EST3 V. 2 only). The relay base does not support the SIGA-LED Remote LED. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on Audible Base SIGA-AB4G - This base is designed for use where the opposite side of closed doors may not reach the detector. localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm This detector can be operated in environments where brief air signal. The optional SIGA-CRR Polarity Reversal Relay can be velocity gusts of up to 300 ft per minute (1.52 m/s) are allowed. used for sounding to other audible bases on the same 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Page 3 of 4 D A T A S H E E T 85001-0291 Not to be used for installation purposes. Issue 8 05-18-11 Specifications Sensing Element Ionization - 1.0 µC Americium 241 Air Velocity Range 0 to 75 ft/min (0 to 0.38 m/s), (See Warnings and Cautions) Storage and Operating Operating Temp: 32ºF to 120ºF (0ºC to 49ºC) Environment Storage Temp: -4ºF to 140ºF (-20ºC to 60ºC) Detection & alarm since 1872 Humidity: 0 to 93% RH, Non-Condensing U.S. Altitude: 6,000 ft (1,828 m) maximum T 888-378-2329 Sensitivity Range ULI / ULC - 0.61% to 1.91% obscuration/foot F 866-503-3996 User Selected Alarm Most Sensitive: 0.7%/ft.; More Sensitive: 1.0% /ft. Normal: 1.2% /ft. Sensitivity Settings Less Sensitive: 1.4% /ft.; Least Sensitive: 1.6% /ft. Canada Chubb Edwards Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings T 519 376 2430 Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) F 519 376 7258 Operating Current Quiescent: 45µA @ 19 V; Alarm: 45µA @ 19 V Emergency Stand- alone Alarm Mode: 18mA Pulse Current: 100 µA (100 msec) During Southeast Asia T : +65 6391 9300 Communication: 9 mA maximum F : +65 6391 9306 Construction & Finish High Impact Engineering Polymer - White Compatible Mounting Bases SIGA-SB Standard Base, SIGA-RB Relay Base, SIGA-IB Isolator India Base, SIGA-AB4, SIGA-AB4G Audible Bases T : +91 80 4344 2000 F : +91 80 4344 2050 LED Operation On-board Green LED - Flashes when polled On-board Red LED   - Flashes when in alarm Both LEDs - Glow steady when in alarm Australia (stand-alone) Compatible Remote Red LED SIGA-LED Flashes T +61 3 9239 1200 when in alarm F +61 3 9239 1299 Compatibility Use With: SIGNATURE Loop Controller Address Requirements Uses one Device Address Europe T +32 2 725 11 20 UL Listed Spacing 30 ft F +32 2 721 86 13 Agency Listings UL, ULC, MEA, CSFM Latin America T 305 593 4301 F 305 593 4300 Ordering Information utcfireandsecurity.com Catalog Description Ship Wt. © 2010 UTC Fire & Security. Number lbs (kg) All rights reserved. SIGA-IS Intelligent Ionization Detector - UL/ULC Listed 0.5 (.23) Accessories SIGA-SB Detector Mounting Base - Standard SIGA-SB4 4 inch Detector Mounting Base c/w SIGA-TS4 Trim Skirt SIGA-RB Detector Mounting Base w/Relay 0.2 (.09) SIGA-RB4 4 inch Detector Mounting Base w/Relay c/w SIGA-TS4 Trim Skirt SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4 inch Detector Mounting Base w/Fault Isolator 0.1 (.04) and SIGA-TS4 Trim Skirt SIGA-AB4G Audible (Sounder) Base 0.1 (.04) Page 4 of 4 D A T A S H E E T 85001-0291 Not to be used for installation purposes. Issue 8

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the SIGA-SB4 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

EST SBC332 68340 Single Board Computer. CPU Board for Evaluation and Hardware / Software Development

EST SBC340 68340 Single Board Computer. CPU Board for Evaluation and Hardware / Software Development

EST SBC341 68340 Single Board Computer. CPU Board for Evaluation and Hardware / Software Development

product

EST SBC8260 CPU Board with PCI Interface and Socket 370

product

EST SIGA2-PS Smoke Detector. Intelligent Photoelectric Detector | Plug-In Mounting | 15.20-19.95 VDC...

product

EST SIGA-SD Intelligent SuperDuct Dectector. Photoelectric | Red LED Alarm Indicator | Green LED Pow...