Elite.Parts chervon right Manufacturers chervon right E chervon right ELAN VITAL chervon right SRB-NA-R-C.21
About product Datasheet FAQ

ELAN VITAL SRB-NA-R-C.21

Description

Elan SRB-NA-R-C.21 Series Safety Relay Array | for Emergency Stop Devices | Interlocking Devices and Others

Part Number

SRB-NA-R-C.21

Price

Request Quote

Manufacturer

ELAN VITAL

Lead Time

Request Quote

Category

PRODUCTS - S

Datasheet

pdf file

SRB-NA-R-C.21-24V-d-1306699776s.pdf

36 KiB

Extracted Text

. T R E Z F SRB-NA-R-C.21 Safety relay array for emergency stop devices, interlocking devices and others ☛5 enabling outputs and 1 monitoring output ☛2 enabling outputs drop-out delayed: 0 ... 30 sec. ☛Selectable extras: – Trailing edge function – Auto reset – Cross-short recognition ☛Time set in 24 stages (at bottom of housing) Features – Relay output: 3 NO, 2 NO time – Input for emergency stop – DIN rail mounting delayed, 1 NC or door monitoring DIN EN 50 022 (Auxiliary NC for monitoring – LED’s for K1, K2, K3, K4, U , U B i must not be used in safety enabling circuits!) – Housing 45 mm, made of thermoplastic in accordance with – Reset, feedback loop UL-94-V-0, red RAL 3000 Approvals Ü LR 13571-30 E 54284 (M) 98107 Front view 47 57 13 23 33 (43) (53) C C1 S1 X1 X2 SRB-NA-R- t ...... s C.21-24V U U Bi K1 K3 Fuse K2 K4 D D1 S2 X2.1 L62 48 58 14 24 34 (44) (54) Product range Type Enabling outputs Operating voltage Part no. SRB-NA-R-C.21-24V 3 NO/2 NO /1 NC 24 VAC/VDC 600 0790 92 R P - G B SRB-NA-R-C.21 (continued) Example for dual-channel door Wiring diagram L1 monitoring using two limit switches Open (one with positive opening contacts) and **** Closed external reset button. K B Reset Dual-channel output, suitable for contact reinforcement or contact multiplication, K A 47 57 using relays or contactors with positively C C1 X2 X2.1 S1 X1 S2 13 23 33 (43) (53) guided contacts. **** = Feedback loop K1 K2 Wire breakage and earth leakage in the F2 * K1 Trigger monitoring circuits are detected. circuit F1 K1 K A K4 K3 K3 * Fuse F2 (front cover) 1 A, TIMER TIMER fuse F1 (internal) 1.25 A K2 K2 K B K1 K3 K2 K4 K4 D D1 L62 14 24 34 48 58 (44) (54) K K A B N For further examples refer to page 94/95 Model specific Operating voltage 24 VDC –15%/+20%, residual ripple max. 10% Technical data 24 VAC –15%/+6% (refer to page 157 Frequency 50/60 Hz (for AC operating) for general data) Fuse (power supply) T 1.0 A/250 V (internal T 1.25 A/250 V) 7 Power consumption max. 4.0 VA, plus monitoring output L62 Switching capacity (enabling contacts) 230 VAC, 4 A ohmic (inductive with suitable suppression) NO 43/44, 53/54: DC 13: 24 VDC/2 A; AC 15: 230 VAC/3 A Fuse (enabling contacts) 4 A slow blowing Switching capacity (monitoring contacts) L62: max. 500 mA Application category AC 15/DC 13, DIN VDE 0660 Part 200 Pick-up delay ≤ 30 ms Drop-out delay ≤ 60 ms Contact material / contacts AgSnO, self cleaning, positively driven Contact resistance max. 100 mOhm when new Air and creeping distances DIN VDE 0110-1 (04.97), 4 kV/2 Connections Self lifting screw terminals min. 0.5 qmm, max. 2.5 qmm Dimensions H/W/D 83 mm/45 mm/140 mm Weight 480 g Ambient operating temperature –25 °C ... +45 °C (derating curve page 157) 7 Mechanical life 10 switching cycles Terminal labeling DIN EN 60 445/DIN 40 719 Part 2 93 SRB-NA-R-C.21 (continued) Wiring example: Wiring example: Input level Input level C1 S1 X1 C1 C1 X1 Single-channel emergency Dual-channel emergency stop switch according to stop switch according to EN 60 204-1. EN 60 204-1. Wire breakage and earth Wire breakage and earth leakage in the emergency Emergency leakage in the emergency Emergency Reset Reset switch off switch off stop circuits are detected. stop circuits are detected. With external reset button. Cross-shorts in the emergency stop circuits are Safety category 2 not detected. in accordance with EN 954-1. With external reset button. Safety category 3 or 4 in accordance with QS QS EN 954-1. 1 1 0 0 S1 S 2 X 2 S1 S2 X2 Wiring example: Wiring example: Input level Input level C1 D1 X1 C1 S1 X1 Dual-channel emergency Single-channel door stop switch according to monitoring according to Open EN 60 204-1. EN 1088 limit switch with positive opening contact. Closed Wire breakage and earth leakage in the emergency Wire breakage and earth Emergency Reset Reset stop circuits are detected. switch off leakage in the door monitoring circuits are Cross-shorts in the detected. emergency stop circuits are detected. With external reset button for increased safety To enable cross-short requirements. monitoring: Set switch "QS" (bottom of housing) Safety category 2 to 1. in accordance with QS QS EN 954-1. With external reset button. 1 0 1 0 Safety category 3 or 4 in accordance with S1 S2 X2 S1 S2 X2 EN 954-1. Wiring example: Wiring example: Input level Input level C1 D1 X1 C1 C1 X1 Dual-channel door monitoring Dual-channel door according to EN 1088, one monitoring according to Open Open limit switch with positive EN 1088, one limit switch Closed Closed opening contact. with positive opening contact. Wire breakage and earth Reset Reset leakage in the door Wire breakage and earth monitoring circuits are leakage in the door detected. monitoring circuits are detected. Cross-shorts in the emergency stop circuits are Cross-shorts in the detected. emergency stop circuits are not detected. To enable cross-short monitoring: Set switch "QS" With external reset button QS QS (bottom of housing) to 1. for increased safety 1 0 1 0 requirements. With external reset button for increased safety Safety category 3 or 4 S1 S2 X2 S1 S2 X2 requirements. in accordance with EN 954-1. Safety category 3 or 4 in accordance with EN 954-1. 94 SRB-NA-R-C.21 (continued) Wiring example: Wiring example: Power level Power level Single-channel output Dual-channel output L1 L1 Suitable for contact KB Suitable for contact KB KA KC KA KC reinforcement or contact reinforcement or contact * 47 * multiplication, using relays multiplication, using relays 13 43 23 13 (43) or contactors with or contactors with KA X1 X2 X1 X2 KA positively guided contacts. positively guided contacts. 14 44 KB 14 24 48 KB (44) KA KB KC KA KB KC N N * Reset button wired in * Reset button wired in series to feedback loop. series to feedback loop. Advice: Advice: 47 57 For "Automatic reset" Drop-out delay of the (43) (53) X1 apply jumper X1-X2. enabling outputs 47/48 and 57/58 adjustable from When using external reset 0–30 sec. button (X1-X2.1), unit is triggered by trailing edge Enabling outputs 43/44 function. and 53/54 correspond Reset to STOP category 1 Reset button wired in in accordance with series to feedback loop. EN 60 204-1. Enabling outputs 47/48 and 57/58 correspond 7 to STOP category 1 in accordance with EN 60 204-1. (44) (54) X2.1 48 58 Time S1 = 1, S1 = 0, S1 = 1, S1 = 0, in seconds S2 = 1, S2 = 1, S2 = 0, S2 = 0, Rear view S3 = 1, S3 = 0, S3 = 1, S3 = 0, S4 = 1 S4 = 1 S4 = 0 S4 = 0 IV V III VI Max I 0.44 2.30 3.5 18 II Min I 1 0 II 0.62 2.45 5.0 20 QS S4 S3 1 III 0.87 2.70 7.0 22 0 S2 S1 IV 1.05 2.85 8.5 23 V 1.27 3.05 10.2 25 VI 1.77 3.55 14.2 29 Tolerance: ± 5% 95

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the SRB-NA-R-C.21 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

ELAN VITAL S30T ATX SERVER W 2X250WATT 8X5.4

ELAN VITAL S50 HOT SWAP MODULE ULTR W.4 HDD

ELAN VITAL P S SECOND FAN CAGE