Elite.Parts chervon right Manufacturers chervon right E chervon right EEC AEG chervon right LS0710E
About product Specifications Features Datasheet FAQ

EEC AEG LS0710E

Description

EEC AEG LS0710E Contactor - 16 AMP, AC Type, 480 V, mini power relay contactor

Part Number

LS0710E

Price

Request Quote

Manufacturer

EEC AEG

Lead Time

Request Quote

Category

PRODUCTS - L

Specifications

16 Amp Resistive (UL)

AC-1 (16 AMP 600 Volt)

Maximum HP Ratings

3 Phase, 460 Volt 3HP CE

Mechanical Life Operations

10,000,000

Weight

0.25 lbs

Features

Datasheet

pdf file

SH862NSW-1603774762.pdf

1129 KiB

Extracted Text

COMPONENT CONTROLS Type LS05 MINI POWER RELAY SERIES LS07 MINI CONTACTOR SPECIFICATIONS 16 Amp Resistive (UL) 9 AC-1 (16 AMP 600 Volt) Mechanical Life Operations 9 10,000,000 Type LS07 9 Maximum HP Ratings MINI POWER RELAY 3 Phase MINI CONTACTOR 460 Volt 3HP CE SERIES LS05 SPECIFICATIONS 15 Amp Inductive (UL) 9 AC-1 (20 AMP 600 Volt) Mechanical Life Operations 9 AC 10,000,000 Type XLS05 9 Maximum HP Ratings MINI STARTER 3 Phase 460 Volt 5HP Connection Options LS07 • Pressure Wire Terminals • Spade (Plug-On) • PC Board (pin terminal) Low Coil Burden 1.2 Watt Internationally Accepted • CE, UL, IEC, S +, BS, VDE, CSA MINI CONTACTORS Overload Relay Type B05 STARTERS • Ambient Temperature Compensated • Three Pole Plug-on Separate Mount • Differential Single Phasing POWER RELAYS Protection POSITIVE GUIDED RELAYS & CONTACTORS Enclosures • M1 - General Purpose • M12 - Dust Tight • 4X - Non Metal • Water & Dust Tight ELECTRICAL & ELECTRONIC CONTROLS, INC. EE CONTROLS, LTD 17 STEWART COURT 3881 DANBURY ROAD ORANGEVILLE, ONTARIO BREWSTER, NY 10509 CANADA L9W 3Z9 845-278-5777 FAX 845-278-5444 519-941-6845 FAX 519-940-0514 71 E-MAIL: info@eecontrols.com E-Mail: infoeecontrols@on.aibn.com MINI CONTACTOR/STARTERS TYPE LS05 - TYPE B05 (20 Amps General Purpose) MINI CONTACTOR Type LS05 Ratings Maximum HP Ratings ENCLOSED Auxiliary 200 Volt 3 HP � Contacts OPEN NEMA 1 NEMA 4X 230 Volt 3 HP General Purpose 3 POLE Outdoor Dust Tight NO NC 460 Volt 5 HP 600 Volt 5 HP �LS05.10-0 LS05.10-1 LS05.10-4X 1 0 1 Phase �LS05.01-0 LS05.01-1 LS05.01-4X 110 Volt 1/2HP 0 1 $109 List $132 List $40 List 220 Volt 1.5 HP 15 AMP INDUCTIVE ��LS05.10F.0 1 0 AC-1 20 Amp $45 List *NOTE: 20 Amp General Purpose. �Standard Screw Down Pressure Plate Terminal �� Spade Terminal SXLS05-1- SXLS05-4X- MINI STARTER Single Phase SXLS05-0- 1 0 $161 List $184 List $89 List XLS05-4X- XLS05-1- Three Phase XLS05-0- 1 0 $184 List $161 List $89 List RLS05.10-0 RLS05.10-4X MINI REVERSING CONTACTOR Three Phase RLS05.10-1 1 0 RLS05.01-0 RLS05.01-4X RLS05.01-1 0 1 $238 List $116 List $185 List SRXLS05.11-4X- SRXLS05.11-1- MINI REVERSING STARTER Single Phase SRXLS05.11-0- 1 1 $296 List $171 List $243 List RXLS05.11-4X- Three Phase RXLS05.11-0- RXLS05.11-1- 1 1 $296 List $243 List $171 List OPEN 4 POLE Four Poles �LS05-4.00-0 LS05-4.00-4X LS05-4.00-1 0 0 $40 List $132 List $109 List  COIL VOLTAGE SUFFIX Deduction for less wiring - $20 list price from reversing contactor and AC 60HZ 50HZ reversing starter, add -LW to part #. -A 120V 110V Part# example: RXLS05.11-A1-NN-LW $223. Reversing Starter, 120V coil -C 208V/230V 220V 10-14 AMP overload, in NEMA 1 Box, less wiring. -E 480V 440V Dimensions: Contactor, W-1.8”, H-1.9”, Deep-2.2”. -F 600V 550V Starter, W-1.8”, H-3.8”, Deep-2.2”. -D 380V -G 24V 22V TYPE B05 TYPE HS AUXILIARY LS05 Accessory Kits List OVERLOAD RELAY -H 280V/277V 240V Side Mount Front Mount Mechanical Interlock LS05-VB05 $6 DC • Auxiliary Contacts 10 Amp 600V -MSW 12VDC •Price Normally Normally -NSW 24VDC Open Closed List Addition -OSW 48VDC HS05.10 $10 1 0 for DC Side Mount -PSW 120VDC 0 1 HS05.01 $10 Coil. $10 2 0 HS05.20 $13 -RSW 220VDC HS05.11 $13 1 1 Type B05 Overload has 1N.C. pilot circuit contact included.If a N.O. 0 2 HS05.02 $13 additional contact is needed, P/N HB05-143 includes a N.O. Alarm HS05.01-001 $13 0 1 Contact. See Below. 1 2 HS05.12 $16 Front Mount 0 4 HS05.04 $18 HS05.13 $18 1 3 OVERLOAD 2 2 HS05.22 $18 Complete Suffix HS05.31 $18 3 1 Amp Range Plug-On List  4 0 HS05.40 $18 B05-A $55 -A 0.11-0.17 Front Mount (with B05-B $55 TYPE SH05 -B 0.17-0.26 spade terminal) HS05.01F $10 0 1 B05-C $55 -C 0.26-0.43 MINI RELAYS 1 2 HS05.12F $16 B05-D $55 -D 0.43-0.65 LS05-EV05-60 $66 A.C. OPERATED Timing Module 12-60 VAC B05-E $55 -E 0.65- 1 90-240 VAC LS05-EV05-240 $66 10 pole maximum with auxiliary B05-F $55 -F 0.85-1.3 B05-G $55 With Pressure Wire Screws Terminals -G 1.1-1.6 B05-GN $55 -GN 1.35-2 AC B05-H $55 -H 1.7-2.4 Contacts Operated NO NC List B05-IN $55 -IN 2.2-3.2 B05-JN $55 SH05.22-* 2 2 $40 -JN 3-4.7 B05-K $55 SH05.31-* 3 1 $40 -K 4-6.3 Type EV05 Timer 4 0 $40 SH05.40-* B05-L $55 Diagram with time delay -L 5.5-8 Timer, delays coil B05-M $55 module type EV 05 -M 7.5-10.5 operation. With Flat Plug (Spade) Connectors B05-NN $55 Adjustable 0.5-60.sec. -NN 10-14 AC Surge Suppressor 12-60 VAC Contacts Operated RESET EXTENDER LS05-EB05-60 $14 NO NC List HB05-143 REQUIRED for overload use with external reset 72-240 VAC LS05-EB05-240 $14 2 Parallel 2 2 $45 operation by reset plunger. Includes SH05:22F*- N.O. Aux. Alarm Contact. #HB05-143 $13.00 List Pole Connector LS05-EB05 $ 6 3 1 $45 SH05:31F*- Spare Coils 4 0 $45 OVERLOAD ADAPTER LS05-COIL- $20 SH05:40F*- Terminal for Separate Mount B05-141-142 $13.00 List  See coil voltage suffix 72 Discount Schedule ST (DIN Rail or Panel mountable) Dimensions LS05, SH05, B05 Contactors & Overloads (AC/DC) Side Aux. Dimensions AC Coil Dimensions DC Coil Dimensions Type LS05 , SH05, and HS05 (frame size I , Lateral)with screw terminals. 2 Side MTG 1 Front MTG Voltage Suppresion modle type EB 05 for frontal plug on. Delayed closing module Type EV05 Overload relay type B05 for mounting on contactors Terminal block & snap - on adaptor for type B05, independent mounting TypeHS05(frame size II & IV frontal mounting)with screw terminals 73 MINI STARTERS TYPE XLS07 with TYPE B05 OVERLOADS AMPS (OPEN) TYPE 4X TYPE M1 Auxiliary NEMA 4X H.P. RATING Resistive Cat. No. OPEN NEMA1 Contacts NO NC LIST LIST LIST 115V 230V Single Phase Starter 1 - 16A Non Reversing SXLS07.10-     -4X- $186 - 0- $ 91 - 1- $163 12 16A Reversing  SRXLS07.10-   -0- 145 -1- 217 - 4X- 270 1 - 12 List Price includes three heaters Three Phase Starter 208V 230V 460V 16A Non Reversing XLS07.10- -0- $ 91 -1- $163 -4X- $186 1 - 333 16A Reversing  RXLS07.10- -0- 145 -1- 217 -4X- 270 1 - 333 RXLS07.01- 16A Reversing  -4X- 270 -0- 145 -1- 217 - 1 333 TYPE 4X ENCLOSED STARTERS. Type XLS starters are UL/CSA All Mini Listed starters enclosed in type 4X U.L. Listed enclosures. Reversing units are Type 4X enclosures are designed for outdoor/hose down/dust tight applica- supplied less wiring. tions and are non-metal corrosion resistant. Add $25.00 list for factory wiring. Add Option: Contactors can be supplied with plug-on spade connectors or ter- suffix -W to catalog minal wire pin connectors. number. EXAMPLE: Catalog No. XLS07 - A - F (Full Voltage Starter A - 120V Coil, F - .85 - 1.3 Amp Overload) Note: RXLS07 only available in AC coil voltage. For DC mini reversing see RXLS05 Page 72 OVERLOAD COIL VOLTAGE SUFFIX STANDARD FEATURES Suffix Complete AC 60HZ 50HZ  Amp Range Plug-On List TYPE B05 OVERLOADS - The Reliable Motor Protectors -A 120V 110V -A 0.11-0.17 B05-A $55 -B 0.17-0.26 B05-B $55 -C 208/230V 220V -C 0.26-0.43 B05-C $55 • Direct Heated Bimetals • 600 Volt Rated -D 380V -D 0.43-0.65 B05-D $55 -E 480V 440V • Ambient Compensated • Sealable Precision Setting -E 0.65-1 B05-E $55 -G 24V 22V -F -20ºC to + 60ºC • Protected Heaters 0.85-1.3 B05-F $55 -G 1.1-1.6 B05-G $55 • Plug-On O.L. Block • 100% Factory Set  DC -Add $10 List per coil -GN 1.35-2 B05-GN $55 • Optional Separate Mount • NEMA Class 10 -MSW 12VDC -H 1.7-2.4 B05-H $55 -IN • NO & NC Contacts -NSW 24VDC 2.2-3.2 B05-IN $55 -JN 3-4.7 B05-JN $55 -OSW 48VDC -K MINI OVERLOADS 4-6.3 B05-K $55 -PSW 120VDC -L 5.5-8 B05-L $55 -RSW 220VDC -M 7.5-10.5 B05-M $55 SW Single Winding DC Power -NN 10-14 B05-NN $55 Plant. DC Coils are not available in RLS07. Technical Data B05- -** HB05-143 Rated insulation voltage 600V, Resistive Amps 16A Required for Mechanical life endurance For AC operation: 4 million operation cycles external reset For DC operation: 10 million operation cycles Plug-On overload Unit AC1 duty Resistive Admissible operational frequency: 50 operations/hour (Plug-On overload included as standard Contact life expectation under full load and rated operational current: 150,000 ops (16 Amp) when complete starter is purchased.) AC3 duty Motor Load  #B05- $55 LIST Allowed frequency of operations at full load and uniteruppted duty: 3000 ops/h Separate Mount O.L. Adaptor Contact life expectation under full load at rated power amd AC 3 duty: 400,000 operations #B05-141-142 $13 LIST AC 11 duty Heavy Pilot Duty 10 Amp Plate Adaptor for assembling O.L. Type #B05 to Rated make/break capacity up to 200V 60A Minicontactor LS07 Allowed frequency of operations at full load and uninterrupted duty: 600 ops/h DC 11 duty Standard Duty (Plate adaptor is included as standard when Short Circuit Protection Max. back-up fuse: 16A slow complete starter is purchased.) Coil Ratings #B05-LS07-ADPT $1.50 LIST For AC operation: Pick-up/sealing 16VA/4.9VA (voltage tolerance -25% - +10%) Plate Adaptor is not needed when XLS07/B05 Starter is DIN Rail mounted. For DC operation: Pick-up/sealing 2.4W (voltage tolerance -15% - +10%) HB05-143 REQUIRED for overload use with external (for 24V: 1.2W for operating range 0.8 to 1.7V) reset operation by reset plunger. (for special version consult factory) N.O. Aux. Alarm Contact HB05 - 143 $13.00 List Switching times for 1.0V for AC operation closing delay 9 to 30 millisecs opening delay 5 to 25 millisecs for DC operation closing delay 10 to 35 millisecs opening delay 2 to 8 millisecs 74 Discount Schedule ST MINI-CONTACTORS TYPE LS07 3/4” 1 POSITIVE GUIDED TYPE SH04 RELAYS AND TYPE LS07 CONTACTORS 1/2” 1 Certiifed as Positive Guided AEG Relays and Contactors 1. Independent Test Lab Certified per IEC 947-5-1 5/8” 2. 100% Quality Tested per IEC 947-5-1 1 H.P. RATING AMPS TYPE M1 Auxiliary OPEN 1 Phase 3 Phase TYPE 4X (OPEN) NEMA1 Contacts Cat. No. LIST LIST Resistive LIST NO NC 115V 230V 208V 230V 460V AC OPERATED MINI CONTACTOR TYPE LS07 With Pressure Wire Screw Terminals 1 2 3 3 3 16A LS07.10- -0 $36 -1 $105 -4X $128 1 - LS07.01- -0 36 -1 105 -4X 128 1 2 3 3 3 16A - 1 LS07.22 -0 36 LS07.40 -0 36 With Flat Plug (Spade) Connectors NOTE: In 12 3 3 3 LS07F.10- -0 $36 Catalog No. 16A .10 indicates 1-NO Contact; 123 3 3 16A LS07F.01- -0 36 .01 indicates 1-NC Contact. CONTACT POWER AUXILIARIES COIL VOLTAGE SUFFIX CODE N.O. N.C. N.O. N.C. AC 60HZ 50HZ DC• LS07.10 3- 1- SPADE CONNECTOR -A 120V 110V -MSW 12VDC LS07.01 3- -1 (Single or Double Spade) -C 208/230V 220V -NSW 24VDC LS07.22 22 -- Check with factory for cost. -OSW 48VDC -D 380V LS07.40 4 - - - -PSW 120VDC -E 480V 440V DC OPERATED MINI CONTACTOR TYPE LS07 -RSW 220VDC -G 24V 22V 3 Pole Non-Reversing + $10 LIST for DC Coil With Pressure Wire Screw Terminals • SW Single Winding DC Power Plant 16A 1 2 3 3 3 LS07.10- -0 $46 16A LS07.01- -0 46 1 2 3 3 3 With Flat Plug (Spade) Connectors 1 2 3 3 3 16A LS07F.10- -0 $46 16A 1 2 3 3 3 LS07F.01- -0 46 TYPE 4X ENCLOSED STARTERS. Type XLS starters are UL/CSA Listed starters enclosed in type 4X U.L. Listed enclosures. Type 4X enclosures are designed for outdoor/hose down/ dust tight applications and are non-metal corrosion resistant. CONTACT CONFIGURATION DESCRIPTION phase systems when con- Minicontactor Type LS07, sented by solenoid valves designed for motor control, trolling motor loads. LS07 and clutch couplings. and distinct small size. As is particularly recommended such, they are recommended for metal and woodworking 10 E for space saving in industrial machines, for textile and Type LS 07.10 construction machinery and control, electronic control and disribution systems. other commercial and industrial applications. The Type LS07 Other loads for minicontac- Minicontactor has been tors are resistive, such as heating and lighting circuits, proven dependable on both three phase and single or inductive loads repre- 01 E Type LS 07.01 For TYPE LS05 - MINI Contactor, 20 Amp 600V, see LS05 Miniature Contactor System. Discount Schedule ST 75 p.76 SH05 POSITIVE GUIDED DESIGN 16A MINI RELAYS MINI RELAYS - POSITIVE GUIDED DESIGN FOR SAFETY CIRCUITS Type SH05 Mini Relays are ideal for Auxiliary wiring and remote control schemes.Taking as little as 2 Watts pick up, the 24 Volt DC Mini Relay and Mini Contactor LS07 are ideal for operation of most elec- tronic control systems as an interface relay. Mini Relay SH05 is certiŢed as a “Positive Guided Design” per the IEC 947-5 standard and are independent test laboratory CertiŢed. Ordering - Replace astric * with coil voltage sufŢx TYPE SH05 from sufŢx chart below. Part# Example: RELAY 2 N.O./N.C. 16 Amp Relay 120 Vac Coil 16 Amps Ith Part # SH05. 22-A AC/DC OPERATED RELAYS With Pressure Wire Screw Terminals With Flat Plug (spade) Connectors AC Operated Contacts AC Operated DC Operated DC Operated Contacts List 16 I th Amps List NO NC List List NO NC SH05. 22-* $ 40 2 2 $ 50 2 2 $ 55 SH05 F.22-* $ 45 SH05. 31-* $ 40 3 1 $ 50 3 1 SH05 F.31-* $ 45 $ 55 SH05. 40-* $ 40 4 0 $ 50 4 0 SH05 F.40-* $ 45 $ 55 Voltage Part Number List Timers Surge Suppressors Part Number List Each 12-60 VAC LS05-EV05-60 $66 12 - 60 VAC LS05 -EB05 - 60 $14 90-240 VAC LS05-EV05-240 $66 72 - 240 VAC LS05 - EB05 - 240 $14 Timer Module can be top mounted or side mounted to any SH05/LS05 Part Number List Each Replacement Coils Relay/Contactor.(AC/DC) LK-C130 - * $ 20 Part Number List Each Jumpers LS05 - EB05 $ 6 * Replace with Coil Voltage SufŢx From Chart above. Parallel Pole Connector Auxiliaries (A600UL) * Coil Voltage SufŢx NORMALLY NORMALLY AC* 60HZ 50HZ Part # LIST OPEN Closed 110V HSO5.10 $10 -A 120V 1 0 220V HS05.01 $10 -C 208V/230V 0 1 440V -E 480 V 550V -F 600V 380V HS05.20 $13 -D Side Mount 2 0 22V HS05.11 $13 -G 24V Auxiliary 1 1 HS05.02 $13 280V/277V 240V -H 0 2 HS05.01-001 $13 0 1 DC* HS05.12 $16 1 2 HS05.04 $18 0 4 12VDC -MSW HS05.13 $18 1 3 24VDC -NSW HS05.22 $18 2 2 48VDC -OSW HS05.31 $18 3 1 120VDC -PSW Top Mount HS05.40 $18 4 0 Auxiliary 220VDC -RSW Discount Schedule ST p.77 SH5 Positive Guided 20A Relays (20 Amp) Positive Guided Relays 20 Amp AC & DC Positive Guided Relays 29 85 Space Saving Dimensions AC Coil = 85mm Depth DC Coil = 115mm Depth Auxiliary 29mm Depth Type For critical safety circuits, self checking duplicate circuits can be required.The Positive Guided following type SH multipole relays have Type SH5 Relays (4 pole) positive guided contacts.This “Positive User BeneŢts Guided Design” Assures that no Normally SH5 Relays are loaded with features permitting Open contacts may be simultaniously convenient to installation and allow more ţexible closed with Normally closed contacts. In the conŢgurations. event that a normally open contact welds in, They conform to both international standards and the Normally closed contact will have a US approvals. SH5 Relays included duel (US / minimum Gap of 0.5mm. European) marking to assure global acceptance. “Positive Guided” contacts are not positive Available Worldwide break or positive opening contacts. Recognized as one of the leading heavy duty industri- al product lines. Type SH relays are available in over * Added Auxiliaries to SH5 relays DO NOT 100 countries including every industrial nation. meet positive guided safety circuit standards. *Per the IEC safety standard (IEC 947-5-1) Industry Accepted & Preferred Contact Rating Per Pole Reliability demanding industries steel, oil,cement, AC-15 chemical, automotive, widely use and demand type CONTINUOUS Max Amperes CARRYING CURRENT Voltage SH controls in their systems. Rating AC-15 10 Part # with AC Coil Poles AC Coil DC Coil 230 20 AMP 10 * Add coil sufŢx NO NC Operation Operation 400 I th 5 Basic 4 pole 480 4 SH5.40-* 0 $62 600 4 $90 DC - 13 Amp Ratings SH5.31-* 1 $62 3 $90 24 V 6A SH5.04-* 4 $62 0 $90 48 V SH5.22-* 4A 2 2 $62 $90 20 AMP 110 V 2A I th Adder poles Auxiliaries 220 V 0.7A 10 Amps 4pole(top mount) 440 V 0.35A (A600) Max Aux. *Coil Voltage SufŢx LK-HS7K.10 1 0 $12 $12 LK-HS7K.01 0 1 $12 $12 AC 60Hz 50Hz DC *Auxiliaries not positive guided Auxiliaries (Side Mount) - A 120 V 110 V - MSW 12VDC 10 Amps(A600) - C 208 / 230 V 220 V - NSW 24VDC - D 380 V - OSW 48VDC LK-HS8K.11 1 1 $22 $22 - E 480 V 440 V - PSW 120VDC LK-HS8K.20 2 0 $22 $22 - F 600 V 550 V - RSW 220VDC *Auxiliaries not positive guided - G 24 V 22 V p.42 Modifications & Accessories Page Part # example SH5.40 - A = 120 VAC Coil Discount Schedule ST p.78 Modifications & Accessories Page 60, 61, 62. COMPONENT CONTROLS BREAKER and FUSIBLE COMBINATION TYPE FCXLSK and BCXLSK Fusible Combination (shown with operators) Complete Line of Enclosed Controls • NEMA Type 1 (metal) • NEMA 3R (metal) • NEMA 12 (metal) • NEMA 4X (fiberglass) • X-Proof (contact factory) • Combinations include type XLS starter and overload relay complete with precision ambient compensated heaters and dif- ferential single phasing protec- tion. Breaker • All combination controls are Combination included with safety door inter- lock and padlockable operators. Conformity to Standards IEC 947-4-1 BREAKER and FUSIBLE VDE 0660 EN 60947 BS 5424 COMBINATIONS UL508 Type FCXLSK and BCXLSK ELECTRICAL & ELECTRONIC CONTROLS, INC. 3881 DANBURY ROAD BREWSTER, NY 10509 845-278-5777 FAX 845-278-5444 E-MAIL: info@eecontrols.com EE CONTROLS, LTD 17 STEWART COURT ORANGEVILLE, ONTARIO CANADA L9W 3Z9 519-941-6845 FAX 519-940-0514 E-Mail: infoeecontrols@on.aibn.com 79 Fusible /Non Fusible Combination Controls Fusible /Non Fusible Combination Controls A. UL/CSA Manual Motor Disconnect with door safety interlocks. Industrial Controls Disconnects are load make, load break, UL Listed for motor load switching duty. B. Fuse Blocks are type”J” as standard. For “R” Type, insert at end of part number “R” (same list price), for type cc 30 Amp fuse block - add “cc” . C. Type XLSK Starter and overload relay complete with precision ambient compensated heaters and differential single phasing protection. Fusible Disconnect Type Enclosed Non Fusible (Non Metal) (Metal) (Metal) Design Omit Fuse Fuse General Dust tight Dust Tight Rating Catalog No. Voltage Block Outdoor Block Pupose Drip Tight Max HP Type FC XLS- Amps NEMA4X Deduct NEMA1 NEMA 12/4 -4X NFCXLS -M01 -M4 30 510 620 $620 $ 26 200/230 5 7K-1 - - $ - $ * ** 30 - - 510 $620 $ 26 460 10 7K-2 $ 620 - $ * ** 60 - - 545 $690 $ 26 230 11K-1 $ 690 - 71/2 * $ * * 26 460 30 11K-2 - - 545 690 $690 $ 15 $ $ - * ** - - 26 60 15K-1 700 790 $790 $ 200 10 $ - * ** $ 60 - - 700 $790 $ 26 230 10 15K-2 $ 790 - * ** $ 60 - - 700 $790 $ 26 460 20 15K-3 $ 790 - * ** $ 100 850 $990 $ 26 200/230 22K-1 - - $ 990 - 15 $ * ** 26 460 60 22K-2 - - 850 990 $990 $ 30 $ $ - * ** 100 - - 1,170 1,430 $1,430 $ 52 200/230 20/25 37K-1 $ - ** $ * 100 - - 1,170 $1,430 $ 52 460 50 37K-2 $ 1,430 - * ** $ 100 - - 1,390 $1,650 $ 52 200/230 25/30 45K-1 $ 1,650 - * $ * * $ 52 460 100 45K-2 - - 1,390 1,650 $1,650 60 $ $ - ** * 88 200 55K-1 - - 2,150 2,660 $2,660 $ 230 40 $ $ - * ** 200 - - 2,150 2,660 $2,660 $ 88 460 75 55K-2 $ - ** $ * 200 - - 2,630 $3,280 $ 88 200/230 40/50 75K-1 $ 3,280 - $ * ** 200 - - 2,630 $3,280 $ 88 460 100 75K-2 $ 3,280 - * $ * * 190 200/230 400 110K-1 - - 4,680 5,200 $5,200 $ 60/75 $ $ - * ** - - 190 400 110K-2 4,680 5,200 $5,200 $ 460 150 $ $ - * ** - - 400 5,600 $7,050 $ 190 200/230 100 160K-1 * $ 7,050 - * * $ 400 - - 5,600 $7,050 $ 190 460 250 160K-2 $ 7,050 - ** $ * 600 - - 9,260 $11,510 $ 290 200/230 220K-1 $ 11,510 - 125/150 * ** $ 290 460 600 220K-2 - - 9,260 11,510 $11,510 $ 300 $ $ - * ** 600 - - 230 200 280K-1 * ** 600 - - $ $ 460 400 280K-2 $ $ * ** 600 Check With F $ actory $ 230 250 375K-1 - - $ $ * ** 600 - - $ $ 460 375K-2 500 $ $ * ** $ $ $ $ Steps to Order Motor Starter: For Factory Installed Additions Step 1 - Size Choose from the UL HP and Voltage list per your application. See Page#38, 39 Special Features For Example: 5 HP 230V 3 Phase Part# FC XL7K- 1* Include: Step 2 - Coil * From the coil suffix chart on next page select the appropriate coil suffix Transformers - Primary , secondary For Example:120 VAC Coil = A Part # FC XLS7K-1A- Fusing included Step 3 - Overload Amps** This step requires a suffix for your overload protection, Pilot Lights refer to “OVERLOAD RELAY SUFFIX TABLE”Next Page. HOA ,Start /Stop,on off selector switches,ect. (Example : 5HP @ 230V 3 Phase , if 13 full load Amps= Suffix “N”) Time Delay Relays Step 4 - Enclosure specify “open” or “enclosed” requirments. Phase Loss , Reverse Phase, Voltage Monitors. For Example if NEMA 12 Complete Part # FCXLS7K - 1A - N-M4 p.80 Modifications & Accessories pages 82, 60, 61 Discount Schedule ST

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the LS0710E have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

PILOT LIGHT BASE TERMINAL MODULE WITH OUT LAMP

SURGE PROTECTOR

product

EEC AEG-LS17-CONTACTOR 32 AMP 10 HP

product

EEC AEG LS27-22-E Motor Starter - 2NO, 2NC, 40A, 15HP at 480 VAC

product

EEC AEG LS4.10E CONTACTOR 3P 10AMP COIL 120VAC

product

EEC AEG LS77-NTW3 Transition Module - Contactor 3 Pole 24VDC