Elite.Parts chervon right Manufacturers chervon right D chervon right DURANT chervon right 5-H-1-1-R
About product Datasheet FAQ

DURANT 5-H-1-1-R

Image of DURANT 5-H-1-1-R

Description

Durant 5-H-1-1-R Mechanical Counter. 5 Digit | 800 CPM Count Speed

Part Number

5-H-1-1-R

Price

Request Quote

Manufacturer

DURANT

Lead Time

Request Quote

Category

PRODUCTS - 5

Datasheet

pdf file

Durant-5-H-1-1-R-datasheet1-1284387206.pdf

2446 KiB

Extracted Text

Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers CS Series Stroke Counter 1 Mechanical Totalizers (Stroke) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-5 Mechanical Totalizers (Revolution) . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-14 1 Electromechanical Totalizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-29 1 Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41 1.2 Count Controls/Preset Counters/Totalizers 1 1/16 DIN Battery Powered LCD Count Control. . . . . . . . . . . . . . . . . . . V13-T1-53 1 Eclipse Series Panel Meter 1/16 DIN LCD Preset Counters with Rate and Time. . . . . . . . . . . . . . . V13-T1-55 Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-57 1 President Series (Totalizers) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-60 President Series (Count Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-64 1 Ambassador Series (Totalizers). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-69 1 Ambassador Series (Count Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-72 PD-Q and PD-ER Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-76 1 Hour Meter 1.3 Tachometers/Ratemeters 1 Courier Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-80 Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-82 1 Ambassador Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-85 1 1.4 Digital Panel Meters E5-324-E Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-89 1 Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-91 1 Fusion Integrated Machine Control 1.5 Timers/Hour Meters 1 Electronic Timers/Hour Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-99 Electromechanical Timers/Hour Meters . . . . . . . . . . . . . . . . . . . . . . . V13-T1-105 1 Hour Meter/Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-111 1 1.6 Flow Totalizers, Transmitters and Controls Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-114 1 1.7 Fusion Integrated Machine Control 1 Fusion Integrated Machine Control . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-119 1 1.8 Special Function Controls President Position Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-124 1 1.9 Temperature Controls 1 TC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-128 1 1.10 Accessories and Encoders DIN Rail Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-132 1 C-Face Ring Tachometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-133 Magnetic Pickup Sensor and Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-134 1 Rotary Contactor—ES9513/ES9513RS . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-134 1 Measuring Wheels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-135 Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-135 1 Shaft Encoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-136 1 1.11 Accessories Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-145 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-1 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Contents Totalizers 1 Description Page Totalizers 1 Product Selection Guide . . . . . . . . . . . . . . . . . V13-T1-3 1 Mechanical Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-5 1 Revolution . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-14 Electromechanical . . . . . . . . . . . . . . . . . . . . . . V13-T1-29 1 Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41 Learn 1 Online 1 1 1 1 1 Product Overview Totalizers are used in a wide Application Example 1 variety of applications where accurate totals are needed. Limit Switch 1 Typical applications include counting the number of parts 1 produced, amount of material used, or the number of machine cycles occurring. 1 Totalizers are the simplest and most common type of 1 Finished Parts counter. As an added bonus, some models can perform 1 both totalizing and ratemeter Limit Switch functions. 1 Manufacturing Typical Application Process 1 Parts are fed into a machine or process, an operation is 1 performed, and the finished Raw Parts parts exit the machine or process. The subtract 1 totalizer is used to indicate the number of parts in 1 process. 1 1 1 1 1 1 1 1 V13-T1-2 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Product Selection Guide 1 Totalizers 1 Panel Cutout Characteristics Typical Applications in Inches (mm) Page 1 Mechanical Various size ranges for different duty cycles and Winding and spooling equipment Various mounting V13-T1-5 environments configurations Position display 1 No power supply needed Mechanical piece/cycle counting Long life and always readable display 1 1 1 Electromechanical Various price, voltage and size ranges for different Coin-operated equipment Various mounting V13-T1-29 duty cycles and environments configurations Gaming machines 1 Long life and always readable display Printing presses Secondary machines (e.g. punch press) 1 1 1 E5-024-C Non-replaceable battery (min. eight-year life) Replacement for mechanical counters 0.870 x 1.772 V13-T1-42 (22 x 45) Compact, low cost and high efficiency Transaction counting 1 Eight-digit LCD totalizers Parts counting Manual or electrical reset Position indication or measurement 1 Various counting modes/inputs E5-_24-E Compact device with bright, LED display Count, measure, time where small package and 0.870 x 1.772 V13-T1-44 1 easy-to-read display required (22 x 45) Multiple functions available: count, time, rate, multifunction, double-function Position display 1 24 Vdc Power Motor/pulley RPM 1 Courier Replaceable lithium battery Portable/mobile/remote flow monitoring 1.299 x 2.677 V13-T1-46 (e.g. sewer pumping, pesticide application) (33 x 68) Eight-digit, high-visibility LCD display 1 Position display, RPM Optional backlighting Length measurement (e.g. carpet, cable) Various input options available 1 1 E5-496-E Economical, multifunction display Large, easy-to-read display 1.772 x 3.780 V13-T1-49 (45 x 96) Large, LED characters Position display 1 AC or DC power options Motor/pulley RPM 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-3 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Totalizers, continued 1 Panel Cutout Characteristics Typical Applications in Inches (mm) Page 1 President Bright LED display with 14 mm characters Cut-to-length machinery with batching 2.667 x 5.433 V13-T1-60 (68 x 138) Simple configuration with 14-button tactile keypad Parts batching/palletizing 1 Many different versions fit almost any application Die press positioning control Applications where parameter changes are required 1 Ambassador Eight-digit, high-visibility, two-line LCD display Flow control where simultaneous total and rate 2.667 x 2.667 V13-T1-69 1 display are required (68 x 68) User-configurable control inputs Cut-to-length and other simple processes where Highly flexible control/display 1 flexibility of inputs/outputs required 1 Hour Meter/Counter Combination counter consists of time meter and General counting 1.988 (50.5) dia. or V13-T1-111 adding counter in one DIN rail 1 Service interval for measurement systems Without reset (respiratory ventilators, oxygen machines, dialysis machines) High shock resistance 1 Small appliances Magnified figures UV lamps Protection IP52 (front) 1 Display panels in cars Data retention if power is lost Long service life 1 UL approved 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-4 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Contents Mechanical Totalizers (Stroke) 1 Description Page Mechanical Totalizers (Stroke) 1 X Series/Pushbutton Desk Tally . . . . . . . . . . . . V13-T1-6 CS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-8 1 H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-10 1 D Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-12 Mechanical Totalizers (Revolution) . . . . . . . . . . . . . V13-T1-14 1 Electromechanical Totalizers . . . . . . . . . . . . . . . . . V13-T1-29 Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41 1 1 1 1 1 1 Mechanical Totalizers (Stroke) Product Overview Features 1 ● Eaton’s mechanical totalizers Variety of reset methods are available in a variety of available 1 heavy-duty configurations for ● Accurate counting without applications when power is need for power 1 unavailable. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-5 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers X Series/Pushbutton Desk Tally 1 Product Description 1 X Series Counters Pushbutton Desk Tally Model X Series is a dustproof Ruggedly constructed 1 and rustproof series of counters with feather-touch counters for light and pushbutton operation and medium-duty work. They are maximum readability. 1 sound and durable, requiring Specifications and a minimum of driving effort, dimensions are basically the 1 and have been especially same as the X Series designed for incorporation as counters. Will give long and 1 integral parts of a variety of accurate service in areas machines and equipment. requiring hand counting or 1 during hand operations. 1 Product Selection 1 When Ordering Specify ● 1 To determine a model Number of figures number from the Product ● Drive Selection table for Model X 1 Series Stroke Counters and Pushbutton Desk Tallies, 1 consider: 1 X Series Stroke Counters and Pushbutton Desk Tallies X Series Stroke Counter No. of Order 1 Figures Drive Reset Mounting Catalog Number Number 5 LH lever Knob Base 5-X-1-1-L 40272401 1 4 RH lever Knob Base 4-X-1-1-R 40263401 5 RH lever Knob Base 5-X-1-1-R 40272402 1 1 1 Pushbutton Desk Tally 5 LH lever Knob Base 5-X-1-1-L-REV 40272400 1 5 RH lever Knob Base 5-X-1-1-R-REV 40272403 1 4 Push bar Knob Base 4-X-2 21619400 4 Pushbutton Knob Base 4-X-2-A 33245400 1 1 1 1 Note 1 Reverse stroke. 1 1 1 1 1 1 1 1 V13-T1-6 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 4 or 5 1 Speed 1000 cpm 1 Shaft 0.125 in (3.2 mm) diameter stainless steel Drive Drive parts of nylon 1 Bearings Oil-less, maintenance free Finish Black frame and Cycolac black cover 1 1 Stroke operation 33° minimum; 58° maximum Figure size 3/16 in (4.8 mm) high, white-on-black background 1 Reset Knob 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 X Series 1 1.38 (35.1) 0.89 C D 0.14 (22.6) Pre (3.6) 1 Stroke 0.97 1.20 1.44 0.12 12° ±5° (24.6) (30.6) (36.5) 1 (3.2) 0.53 (13.5) 1 45° ±5° Dia. 0.093 (2.36) 0.44 (11.1) Index Stroke 58° ±5° A 1 B Total Stroke 1 Model A B C D 1 4-X-1-1_ 1.86 (47.2) 2.76 (70.2) 0.62 (15.7) 0.89 (22.6) 5-X-1-1_ 2.16 (54.8) 3.06 (77.8) 0.81 (20.6) 0.95 (24.1) 1 Note 1 1 Operating stroke angles apply to forward stroke counter only. Check factory for angles of reverse stroke counter. 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-7 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers CS Series 1 Product Description 1 Model CS Series of small, compact, top reading stroke counters is designed for 1 use in most industrial applications. These counters 1 are ruggedly built and feature a single casting case, which 1 assures great rigidity and a tight seal for working parts. 1 1 Product Selection 1 When Ordering Specify ● To determine a model Number of figures 1 number from the Product ● Drive lever Selection table for Model CS Series Stroke Counters, 1 consider: 1 CS Series Stroke Counters CS Series Stroke Counter No. of Order 1 Figures Drive Reset Mounting Catalog Number Number 5 RH lever Wing nut Base 5-CS-1-1-R 31062401 1 1 5 RH lever Wing nut Base 5-CS-1-1-R-RP 01464400 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification 1 Figures 4 or 5 Speed 600 cpm 1 Stroke operation 37-1/2° minimum; 75° maximum Shaft 0.25 in (6.4 mm) diameter stainless steel, rustproof 1 Drive Accurately machined, hardened steel parts Bearings Oil-less, maintenance free 1 Figure size 11/32 in (8.7 mm) high, black-on-white background 1 Reset Contoured wing nut Finish Black frame 1 Operating lever Cast zinc. Adjustable to any position. Furnished complete with pull spring. 1 Note 1 Special feature: rustproof. 1 1 1 1 1 1 V13-T1-8 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 CS Series Dia. 0.156 1 4 Mtg. Holes 0.73 D 0.47 (18.6) 1 (11.9) 0.42 (10.7) 1 1 Stroke 0.50 (12.7) 37.5° Min. – 75° Max. 0.92 1 (23.4) 1 1 0.56 1.25 2.09 (14.3) (31.8) (53.1) 1.34 1 (34.1) Dia. 0.25 0.22 1 1.19 (6.35) A (5.6) (30.2) B 1.25 1 1.00 C (31.8) (25.4) 1.69 (42.9) 1 Model A B C D 1 4-CS-1_ 3.12 (79.2) 3.50 (88.9) 4.03 (102.3) 1.87 (47.6) 5-CS-1_ 3.62 (91.9) 4.00 (101.6) 4.53 (115.0) 2.38 (60.5) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-9 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers H Series 1 Product Description action is designed with or back mounting. Model “H” 1 Model H Series heavy-duty overstroke so counter does has earned the reputation of counters are designed for not bottom, increasing life being the “work horse” of hard usage and long, trouble- 1 and permitting easier industrial counters. Wing nut free service. They are high installation. The sturdy cover or tamper-proof reset lock speed, streamlined counters 1 is stamped steel, locked into which requires a key to reset constructed of the highest position on a heavy, die-cast the counter, guarding against quality materials and drive 1 base of a special alloy. A unauthorized resetting or shaft moves in oil-less heavy steel mounting plate is tampering. bearings. All shafts are adjustable for either bottom stainless steel. The drive 1 1 Product Selection 1 When Ordering Specify ● ● To determine a model Number of figures Type of reset 1 number from the Product ● (lock or wing nut) Drive lever location Selection table for Model H (left or right side) 1 Series Stroke Counters, consider: 1 H Series Stroke Counters H Series Stroke 1 Counter No. of Order Figures Drive Reset Mounting Catalog Number Number 1 5 RH lever Wing nut Base 5-H-1-1-R 40205400 5 LH lever Wing nut Base 5-H-1-1-L 40205401 1 1 5 RH lever Wing nut Base 5-H-1-1-R-REV 00597400 1 1 5 LH lever Wing nut Base 5-H-1-1-L-REV 00598400 2 5 RH lever Wing nut Base 5-H-1-1-R-RP 40205404 1 2 5 LH lever Wing nut Base 5-H-1-1-L-RP 40205405 5 RH lever Lock reset Base 5-H-1-2-R 40206404 1 5 LH lever Lock reset Base 5-H-1-2-L 40206405 2 5 RH lever Lock reset Base 5-H-1-2-R-RP 40206400 1 5 RH lever Wing nut Rear 5-H-1-4-R 00507400 1 5 RH trip arm Wing nut Base 5-H-5-A 31049400 5 RH trip arm Wing nut Base 5-H-5-B 31049401 1 5 LH trip arm Wing nut Base 5-H-5-C 31049402 5 LH trip arm Wing nut Base 5-H-5-D 31049403 1 5 RH trip arm Lock reset Base 5-H-6-A 01533400 5 RH trip arm Lock reset Base 5-H-6-B 01534400 1 5 LH trip arm Lock reset Base 5-H-6-C 01535400 1 5 LH trip arm Lock reset Base 5-H-6-D 01536400 Notes 1 1 Special feature: Reverse stroke. 2 Special feature: Rustproof. 1 1 1 1 1 1 V13-T1-10 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 Direction Location for 5H5 and 5H6 1 1 C A 1 1 B D 1 1 General Specifications Description Specification 1 Figures 5 1 Speed 800 cpm Stroke operation 37° stroke to count; 60° maximum stroke 1 Shaft 0.31 in (7.9 mm) diameter stainless steel, rustproof Drive Accurately machined, hardened steel parts; Geneva drive for extra long life 1 Bearings Oil-less, maintenance free Figure sizes 11/32 in (8.7 mm) high, black-on-white background 1 Reset Wing nut or tumbler lock reset 1 Finish Black frame and cover Operating lever Adjustable to any position. Furnished complete with pull spring for attaching. 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 H Series 1 Lock Reset 0.75 1.20 0.98 0.75 1 C (19.1) (30.6) (25.0) (19.1) 1 2.76 1.0 (70.1) 1 (25.4) 1.80 (45.7) 0.91 1 (23.0) Dia. 0.31 1.12 A (7.92) 1 (28.4) B 2.25 (57.2) 1 Model A B C 1 Five figure units 3.95 (100.4) 4.38 (111.3) 2.75 (69.9) 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-11 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers D Series 1 Product Description Although compact, “D” 1 Model D Series are medium- models are sturdily duty stroke counters available constructed and thoroughly with 4, 5 or 6 figures that 1 tested for accuracy and have been designed for efficient operation. general service on small 1 production machines. 1 Product Selection 1 When Ordering Specify 1 ● To determine a model Number of figures number from the Product ● Drive lever 1 Selection table for Model D Series Stroke Counters, 1 consider: 1 D Series Stroke Counters D Series Stroke Counter No. of Order Figures Drive Reset Mounting Catalog Number Number 1 4 RH lever Wing nut Base 4-D-1-1-R 34269401 1 5 RH lever Wing nut Base 5-D-1-1-R 34269402 6 RH lever Wing nut Base 6-D-1-1-R 34269403 1 4 LH lever Wing nut Base 4-D-1-1-L 34269405 5 LH lever Wing nut Base 5-D-1-1-L 34269406 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification 1 Figures 4, 5 and 6 Speed 400 cpm 1 Shaft 0.25 in (6.4 mm) diameter stainless steel, rustproof Drive Nylon rachet and Delrin drive plate. Right-hand drive standard; left-hand drive available 1 Bearings Oil-less, maintenance free 1 Figure size 1/4 in (6.4 mm) high, black-on-white background Reset Wing nut 1 Finish Black frame and cover Operating lever Adjustable to any position. Furnished complete with pull string 1 1 1 1 1 1 1 1 V13-T1-12 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 D Series C 0.62 (15.7) 1 1 Dia. 0.12 1.25 (3.05) (31.8) 1.72 4 Mtg. 1 (43.6) Holes 1 A 1.62 (41.3) 1 0.50 (12.7) B 1.87 (47.6) 1 Model A B C 1 4-D-1-1_ 1.59 (40.4) 2.20 (55.9) 1.20 (30.6) 5-D-1-1_ 1.92 (48.8) 2.53 (64.3) 1.51 (38.5) 1 6-D-1-1_ 2.26 (57.5) 2.87 (73.0) 1.83 (46.4) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-13 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Contents Mechanical Totalizers (Revolution) 1 Description Page Mechanical Totalizers (Stroke) . . . . . . . . . . . . . . . . V13-T1-5 1 Mechanical Totalizers (Revolution) 1 X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-15 CS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-17 1 D-7 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-19 D-6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-21 1 HDW Series . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-23 T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-25 1 H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-27 Electromechanical Totalizers . . . . . . . . . . . . . . . . . V13-T1-29 1 Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41 1 1 1 1 Mechanical Totalizers (Revolution) Product Overview Features 1 ● Eaton’s mechanical totalizers Variety of reset are available in a variety of configurations available 1 heavy-duty configurations for ● Accurate length applications when power is measurement for 1 unavailable. application where power is not available 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-14 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers X Series 1 Product Description Model X Series are dust- and They are especially designed 1 rust-proof counters designed for incorporation as integral for small, medium-duty units, parts of a variety of equipment 1 accurate, durable and require that gets severe usage under a minimum of driving effort. adverse climatic conditions. 1 1 Product Selection 1 When Ordering Specify ● To determine a model Number of figures 1 number from the Product ● Ratio Selection table for Model X ● Drive shaft location Series Revolution Counters, 1 ● Shaft rotation direction consider: 1 X Series Revolution Counters X Series Revolution Counter No. of Order 1 Figures Drive Rotation Reset Mounting Catalog Number Number 1 4 LH Clockwise Knob Base 4-X-7-1-L-CL 40270406 1 2 4 LH Anti-clockwise Knob Base 4-X-7-1-L-AC 40270404 3 1 4 RH Clockwise Knob Base 4-X-7-1-R-CL 40270407 4 4 RH Anti-clockwise Knob Base 4-X-7-1-R-AC 40270405 1 4 5 RH Anti-clockwise Knob Base 5-X-7-1-R-AC 40275406 1 5 4 LH Clockwise Knob Base 4-X-7-1-L-CL 40270402 1 1 5 5 LH Clockwise Knob Base 5-X-7-1-L-CL 40275402 2 5 4 LH Anti-clockwise Knob Base 4-X-7-1-L-AC 40270400 1 2 5 5 LH Anti-clockwise Knob Base 5-X-7-1-L-AC 40275400 1 3 5 4 RH Clockwise Knob Base 4-X-7-1-R-CL 40270403 3 5 5 RH Clockwise Knob Base 5-X-7-1-R-CL 40275403 1 4 5 4 RH Anti-clockwise Knob Base 4-X-7-1-R-AC 40270401 4 5 5 RH Anti-clockwise Knob Base 5-X-7-1-R-AC 40275401 1 1 Top View—Left-Hand Drive 1 1 2 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 1 Top View—Right-Hand Drive 1 3 4 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 Notes 1 When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 Top view—left-hand drive with clockwise shaft rotation. 1 2 Top view—left-hand drive with anti-clockwise shaft rotation. 3 Top view—right-hand drive with clockwise shaft rotation. 1 4 Top view—right-hand drive with anti-clockwise shaft rotation. 5 Special feature: 10:1 ratio. 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-15 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 4 or 5 1 Speed 1000 cpm in 1:1 ratio; 1 10,000 cpm in 10:1 ratio for intermittent duty Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter 1 Ratio 1:1 and 10:1 standard in 4-X-7 models 10:1 standard in 5-X-7 models 1 Shaft 0.125 in (3.2 mm) diameter stainless steel; standard length 0.44 in (11.1 mm) Bearings Oil-less, maintenance free 1 Figure size 3/16 in (4.8 mm) high, white-on-black background 1 Reset Knob Finish Black frame, Cycolac black cover 1 Drive Right- or left-hand drive; drive parts of Delrin Ratio information 1:1 is one count to each revolution of drive shaft, 10:1 is ten counts to each revolution 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 X Series 1 Dia. 0.12 1.38 (35.1) 0.14 1 (3.2) DCE (3.6) 1 0.97 1.20 1.44 0.12 1 (24.6) (30.6) (36.5) (3.2) 1 0.53 (13.5) 0.45 0.44 (11.1) (11.5) 1 A B 1 Model ABC DE 1 4-X-7-1_ 1.86 (47.2) 2.76 (70.2) 0.62 (15.7) 0.19 (4.8) 0.89 (22.6) 5-X-7-1_ 2.16 (54.8) 3.06 (77.8) 0.81 (20.6) 0.25 (6.4) 0.95 (24.1) 1 1 1 1 1 1 1 1 1 1 V13-T1-16 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com AC CL Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers CS Series 1 Product Description This provides greater rigidity, Model CS Series top reading 1 tighter seal of working parts revolution counters are and more streamlined designed for use in most 1 contour. The unit is compact, industrial applications. The rugged and features a flush entire case is a single casting. 1 mounted window to assure greater visibility. 1 1 Product Selection When Ordering Specify 1 ● To determine a model Number of figures number from the Product ● 1 Ratio Selection table for Model CS ● Drive shaft location Series Revolution 1 ● Shaft rotation direction Counters, consider: 1 CS Series Revolution Counters CS Series Revolution Counter No. of Order 1 Figures Drive Rotation Reset Mounting Catalog Number Number 1 5 RH Clockwise Wing nut Base 5-CS-7-1-R-CL 31060409 1 2 5 RH Anti-clockwise Wing nut Base 5-CS-7-1-R-AC 31060411 3 5 LH Clockwise Wing nut Base 5-CS-7-1-L-CL 00440400 1 1 3 4 RH Clockwise Wing nut Base 4-CS-7-1-R-CL 31057401 1 2 3 4 RH Anti-clockwise Wing nut Base 4-CS-7-1-R-AC 31057403 2 3 5 RH Anti-clockwise Wing nut Base 5-CS-7-1-R-AC 00443400 1 4 5 4 RH and LH Clockwise None Base 4-CS-7-3-CL 31057408 6 5 4 RH and LH Anti-clockwise None Base 4-CS-7-3-AC 31057409 1 1 Top View—Right-Hand Drive 1 1 2 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 1 Top View—Right- and Left-Hand Drive 1 4 6 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 Notes 1 When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 Top view—right-hand drive with clockwise shaft rotation. 1 2 Top view—right-hand drive with anti-clockwise shaft rotation. 3 Special feature: 10:1 ratio. 1 4 Top view—right- and left-hand drive with clockwise shaft rotation. 5 Special feature: 10:1 ratio, non-reset, double shaft. 6 Top view—right- and left-hand drive with anti-clockwise shaft rotation. 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-17 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 4 or 5 1 Speed 600 cpm in 1:1 ratio 1 Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio 1:1 standard 1 Shaft 0.25 in (6.4 mm) diameter stainless steel; standard length 1 in (25.4 mm) Drive Spur gear 1 Bearings Oil-less, maintenance free Figure size 11/32 in (8.7 mm) high, black-on-white background 1 Reset Contoured wing nut 1 Finish Black frame 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 CS Series 0.73 1 (18.6) Dia. 0.156 (3.96) D 4 Mtg. Holes 1 0.42 (10.7) 1 1 0.50 (12.7) 0.92 (23.4) 1 1 Dia. 0.25 2.09 (6.4) (53.1) 1.34 1 (34.1) 1 0.56 1.19 0.22 A (14.3) (30.2) (5.6) B 1 1.25 1.00 C (31.8) (25.4) 1.69 (42.9) 1 Model A B C D 1 4-CS-7_ 3.12 (79.2) 3.50 (88.9) 4.03 (102.3) 1.89 (47.9) 1 5-CS-7_ 3.62 (91.9) 4.00 (101.6) 4.53 (115.0) 2.38 (60.5) 1 1 1 1 1 1 1 V13-T1-18 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers D-7 Series 1 Product Description recommended for braiding Model D-7 Series spur gear 1 machines, low-speed coil end drive units are compact winders, wire measuring counters that meet a variety 1 equipment and all medium- of needs. Accurate, duty revolution applications. dependable and moderately 1 priced, they are especially 1 Product Selection 1 When Ordering Specify 1 ● To determine a model Number of figures number from the Product ● Shaft drive 1 Selection table for Model D-7 ● Shaft rotation direction Series Revolution Counters, ● Reset or non-reset consider: 1 D-7 Series Revolution Counters 1 D-7 Series Revolution Counter No. of Order Figures Drive Rotation Reset Mounting Catalog Number Number 1 1 5 LH Clockwise Wing nut Base 5-D-7-1-L-CL 31127408 1 2 5 LH Anti-clockwise Wing nut Base 5-D-7-1-L-AC 31127405 3 5 RH Clockwise Wing nut Base 5-D-7-1-R-CL 31127431 1 4 5 RH Anti-clockwise Wing nut Base 5-D-7-1-R-AC 31127400 2 5 LH Anti-clockwise None Base 5-D-7-3-L-AC 31127412 1 3 5 RH Clockwise None Base 5-D-7-3-R-CL 31127438 1 Top View—Left-Hand Drive 1 1 2 1 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 1 Top View—Right-Hand Drive 1 3 4 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 Notes 1 When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 Top view—left-hand drive with clockwise shaft rotation. 1 2 Top view—left-hand drive with anti-clockwise shaft rotation. 3 Top view—right-hand drive with clockwise shaft rotation. 1 4 Top view—right-hand drive with anti-clockwise shaft rotation. 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-19 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 5 standard 1 Speed Up to 800 cpm in 1:1 ratio 1 Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio 1:1 standard 1 Shaft 0.31 in (7.9 mm) diameter stainless steel; 0.66 in (16.7 mm) right-hand drive, 0.63 in (15.9 mm) left-hand drive 1 Drive Right- or left-hand spur gear drive Bearings Oil-less, maintenance free 1 Figure size 1/4 in (6.4 mm) high, black-on-white background Finish Black frame and cover 1 Reset Wing nut or non-reset 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 D-7 Series 1 0.12 1.51 0.75 1.17 (3.2) (38.5) (19.0) (29.8) 1 1 Dia. 0.120 Dia. 0.31 0.50 (3.05) (7.9) (12.7) 1 4 Mtg. 1.72 Holes (43.6) 1 1 1.92 (48.8) 1.62 (41.3) 0.50 0.78 1 2.53 (64.3) (12.7) (19.8) 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-20 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers D-6 Series 1 Product Description adapted as accessory Model D-6 right-angle worm 1 equipment on machinery drive counters are ruggedly where right-angle drive is designed for high speeds on 1 desired to permit full view light-duty applications. Small reading of the counter. “D” counters are easily 1 1 Product Selection 1 When Ordering Specify 1 ● To determine a model Shaft rotation direction number from the Product 1 Selection table for Model D-6 Series Revolution Counters, consider: 1 D-6 Series Revolution Counters 1 D-6 Series Revolution Counter No. of Order Figures Drive Rotation Reset Mounting Catalog Number Number 1 1 5 Front and rear Anti-clockwise Wing nut Base 5-D-6-1-AC 31052401 1 1 6 Front and rear Anti-clockwise Wing nut Base 6-D-6-1-AC 31052402 2 5 Front and rear Clockwise Wing nut Base 5-D-6-1-CL 31052404 1 2 6 Front and rear Clockwise Wing nut Base 6-D-6-1-CL 31052405 1 3 5 Front and rear Anti-clockwise Wing nut Base 5-D-8-1-AC 40187401 1 2 3 5 Front and rear Clockwise Wing nut Base 5-D-8-1-CL 40187417 2 3 1 6 Front and rear Clockwise Wing nut Base 6-D-8-1-CL 40187418 2 4 5 Front and rear Clockwise Wing nut Base 5-D-9-1-CL 40187404 1 1 4 5 Front and rear Anti-clockwise Wing nut Base 5-D-9-1-AC 40187410 2 5 5 Front and rear Clockwise Wing nut Base 5-D-90-1-CL 40187414 1 1 5 5 Front and rear Anti-clockwise Wing nut Base 5-D-90-1-AC 40187408 1 Top View of Counter 1 1 1 2 1 1 Anti-Clockwise Shaft Rotation Clockwise Shaft Rotation 1 Notes 1 When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 Top view of counter—anti-clockwise shaft rotation. 2 Top view of counter—clockwise shaft rotation. 1 3 Special feature: Measuring wheels and brackets available for lineal measurement in feet. 4 Special feature: Measuring wheels and brackets available for lineal measurement in yards and 1/8ths. 1 5 Special feature: Measuring wheels and brackets available for lineal measurement in yards. 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-21 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 5 or 6 1 Speed Up to 1500 cpm in 1:1 ratio 1 Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio 1:1 standard 1 Shaft 0.31 in (7.9 mm) diameter stainless steel; 1.25 in (31.8 mm) length standard Drive Worm drive 1 Bearings Oil-less, maintenance free Figure size 1/4 in (6.4 mm) high, black-on-white background 1 Finish Black frame and cover 1 Reset Wing nut 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 D-6 Series 1.16 1 (29.4) 1 1.23 Reading 0.84 (31.4) 1 A Line (21.4) Dia. 0.144 Dia. 0.31 1 (3.66) (7.93) 4 Mtg. 0.12 0.34 2.0 Holes 1 (3.0) (8.7) (50.8) 1 1.62 2.81 (71.4) 0.75 (41.3) 1 (19.0) 0.50 (12.7) 0.66 (16.7) 2.00 (50.8) 3.19 (81.0) 3.62 (92.1) 1 Note 1 1 A = 1.85 in (46.9 mm) for 6 figures and 1.53 in (38.9 mm) for 5 figures. 1 1 1 1 1 1 1 1 1 1 1 V13-T1-22 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers HDW Series 1 Product Description eliminate slipping. They are Model HDW Series are high 1 particularly recommended for speed, end drive revolution quick starting and stopping counters that have the 1 machines, such as coil rugged features of all “H” winders and wire measuring counters, with the addition of 1 or reeling equipment and on double worm drive that applications where produces speeds up to 2000 continuous high speed 1 cpm. Lightweight precision measuring is required. molded wheels reduce centrifugal force and 1 1 Product Selection 1 When Ordering Specify ● To determine a model Shaft drive 1 number from the Product ● Shaft rotation direction Selection table for Model 1 HDW Series Revolution Counters, consider: 1 HDW Series Revolution Counters HDW Series 1 Revolution Counter No. of Order 1 Figures Drive Rotation Reset Mounting Catalog Number Number 1 2 5 RH Clockwise Wing nut Base 5-HDW-7-1-R-CL 31050400 3 5RH Anti-clockwise Wing nut Base 5-HDW-7-1-R-AC 31050401 1 4 5 LH Clockwise Wing nut Base 5-HDW-7-1-L-CL 31050402 5 5LH Anti-clockwise Wing nut Base 5-HDW-7-1-L-AC 31050403 1 1 Top View—Right-Hand Drive 1 2 3 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 1 Top View—Left-Hand Drive 1 4 5 1 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 Notes When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 1 Mounting plate is adjustable for base or back mounting. 2 Top view—right-hand drive with clockwise shaft rotation. 1 3 Top view—right-hand drive with anti-clockwise shaft rotation. 4 Top view—left-hand drive with clockwise shaft rotation. 5 1 Top view—left-hand drive with anti-clockwise shaft rotation. 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-23 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 5 1 Speed Up to 2000 cpm 1 Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio 1:1 only 1 Shaft 0.31 in (7.9 mm) diameter stainless steel; standard length 2 in (50.8 mm) Drive Right- or left-hand drive 1 Bearings Oil-less, maintenance free Figure size 11/16 in (17.5 mm) high, white-on-black background 1 Reset Wing nut or tumbler lock reset 1 Finish Black frame and cover 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 HDW Series 0.98 0.75 1 2.75 (25.0) (19.1) (69.9) 0.96 (24.4) 2.00 (50.8) 1 1 2.76 (70.1) 1.80 1 (45.7) 0.90 (22.9) 1 Dia. 0.312 (7.9) 4.51 0.34 (100.3) 1 (8.5) 4.94 Dia. 0.22 (5.59) (111.3) 1.12 4 Mtg. Holes (28.4) 1 2.25 (57.2) 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-24 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers T Series 1 Product Description heavy machines, engines or Model T Series worm drive 1 motors. Variety of drive revolution counters are permits direct connection. sturdy, high speed 1 Suitable for panel mounting. instruments used on many 1 Product Selection 1 When Ordering Specify 1 ● To determine a model Shaft rotation direction number from the Product 1 Selection table for Model T Series Revolution Counters, consider: 1 T Series Revolution Counters 1 T Series Revolution Counter No. of Order Figures Drive Rotation Reset Mounting Catalog Number Number 1 2 5 Top and bottom Anti-clockwise Wing nut Back 5-T-6-1-AC 40342401 1 1 1 Top View of Counter 1 1 1 1 2 1 Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation 1 Notes 1 When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 Top view of counter—clockwise shaft rotation. 1 2 Top view of counter—anti-clockwise shaft rotation. 3 Special feature: Measuring wheels and brackets available for lineal measurement in feet. 1 4 Special feature: Measuring wheels and brackets available for lineal measurement in yards and 1/8ths. 5 Special feature: Measuring wheels and brackets available for lineal measurement in yards. 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-25 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 5 standard 1 Speed 1500 cpm in 1:1 ratio 1 Rotation direction Clockwise or anti-clockwise determined top looking down Ratio 1:1 standard 1 Shaft 0.31 in (7.9 mm) diameter stainless steel; standard extends 2 in (50.8 mm) top and bottom Drive Hobbed steel and bronze worm gearing; subtracts when reversed 1 Bearings Oil-less, maintenance free Figure size 11/32 in (8.7 mm) high, black-on-white background 1 Reset Left-hand wing nut standard 1 Finish Black frame and face plate 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 T Series 1.38 1 (35.1) 0.62 (15.9) 1 0.75 0.24 2.97 (75.4) (19.1) (6.2) 1 0.47 (11.9) 1 1.87 2.38 (47.6) (60.5) 1 1.41 (35.7) 1 0.25 1.36 (34.5) 2.19 1 (6.4) (55.6) 4.50 (114.2) 1/4-20 UNC-2B 1 5.00 (127.0) 4 Mtg. Holes 1 1 1 1 1 1 1 1 1 1 1 V13-T1-26 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers H Series 1 Product Description speeds up to 800 cpm. They Model H Series are heavy- 1 are available with either right- duty, end drive revolution or left-hand drive, and with counters designed for 1 wing nut reset. industrial use; suitable for 1 Product Selection 1 When Ordering Specify ● To determine a model Drive shaft location 1 number from the Product ● Shaft rotation direction Selection table for Model H Series Revolution 1 Counters, consider: 1 H Series Revolution Counters H Series Revolution Counter No. of Order 1 1 Figures Drive Rotation Reset Mounting Ratio Catalog Number Number 2 5 LH Clockwise Wing nut Base 1.1 5-H-7-1-L-CL 00509400 1 3 5 LH Anti-clockwise Wing nut Base 1.1 5-H-7-1-L-AC 00510400 4 1 5 RH Clockwise Wing nut Base 1.1 5-H-7-1-R-CL 00513400 5 5 RH Anti-clockwise Wing nut Base 1.1 5-H-7-1-R-AC 00514400 1 6 7 5 LH Clockwise Wing nut Base 3.2 5-H-8-1-L-CL 00601400 8 7 5 LH Anti-clockwise Wing nut Base 3.2 5-H-8-1-L-AC 00602400 1 6 7 5 RH Clockwise Wing nut Base 3.2 5-H-8-1-R-CL 00605400 8 7 5 RH Anti-clockwise Wing nut Base 3.2 5-H-8-1-R-AC 00606400 1 6 9 5 LH Clockwise Wing nut Base 1.2 5-H-9-1-L-CL 00619400 1 8 9 5 LH Anti-clockwise Wing nut Base 1.2 5-H-9-1-L-AC 00620400 6 9 5 RH Clockwise Wing nut Base 1.2 5-H-9-1-R-CL 00617400 1 8 9 5 RH Anti-clockwise Wing nut Base 1.2 5-H-9-1-R-AC 00618400 6 j 5 LH Clockwise Wing nut Base 1.2 5-H-9-0-1-L-CL 00611400 1 6 j 5 RH Clockwise Wing nut Base 1.2 5-H-9-0-1-R-CL 00609400 8 j 1 5 RH Anti-clockwise Wing nut Base 1.2 5-H-9-0-1-R-AC 00610400 1 For 5-H-8 and 5-H-9 Series Top View—LH Drive Top View—RH Drive Top View—RH and LH Drive Counters, drive shaft extends 1 from both sides of the 2 4 6 counter. Specifying RH or LH drive will determine the 1 Clockwise Shaft Rotation Clockwise Shaft Rotation Clockwise Shaft Rotation location of the reset (i.e. LH drive will have reset on the 1 right-hand side of the 3 5 8 counter, and RH drive will 1 have reset on left-hand side Anti-Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation Anti-Clockwise Shaft Rotation of the counter). 1 Notes When shaft is turned in the reverse direction of rotation, the counter will subtract. 1 1 Mounting plate is adjustable for base or back mounting. 2 Top view—left-hand drive with clockwise shaft rotation. 3 1 Top view—left-hand drive with anti-clockwise shaft rotation. 4 Top view—right-hand drive with clockwise shaft rotation. 5 Top view—left-hand drive with anti-clockwise shaft rotation. 1 6 Top view—right-hand and left hand drive with clockwise shaft rotation. 7 Special feature: Measuring wheels and brackets available for lineal measurement in feet. 1 8 Top view—right-hand and left hand drive with anti-clockwise shaft rotation. 9 Special feature: Measuring wheels and brackets available for lineal measurement in yards and 1/8ths. j Special feature: Measuring wheels and brackets available for lineal measurement in yards. 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-27 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 5 1 Speed Up to 800 cpm 1 Rotation direction Clockwise or anti-clockwise when viewed from right-hand end of counter Shaft 0.31 in (7.9 mm) diameter stainless steel; standard length 2 in (50.8 mm) 1 Drive Right- or left-hand drive Bearings Oil-less, maintenance free 1 Figure size 11/32 in (8.7 mm) high, white-on-black background Reset Wing nut 1 Finish Black frame and cover 1 Mounting bracket available Order number 01465400 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 H Series 2.75 1 0.98 (69.9) (25.0) 2.00 1 (50.8) 2.76 1 (70.1) 0.91 1 (23.0) 1.80 (45.7) 1 Dia. 0.312 3.95 (7.92) 0.34 1 (100.4) (8.5) Dia. 0.220 4.38 (111.3) 1.12 4 Mtg. Holes 1 (28.4) 2.25 (57.2) 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-28 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Contents Electromechanical Totalizers 1 Description Page Mechanical Totalizers 1 Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-5 Revolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-14 1 Electromechanical Totalizers 1 Micro Display Counter . . . . . . . . . . . . . . . . . . . V13-T1-30 SE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-32 1 MF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-34 RMF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-36 1 ME Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-38 Electronic Totalizers . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-41 1 1 1 1 1 Electromechanical Totalizers Product Overview Features Standards and Certifications 1 ● ● Eaton’s electromechanical Available with reset and UL certifications on some counters provide accurate without products (see individual 1 counting from a variety of ● product pages for details) Always readable display electrical signals and a display ● Variety of mounting 1 that is always readable, even options when power is not present. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-29 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Micro Display Counter 1 Product Description Features Standards and Certifications ● ® ● Different viewing ● 1 Eaton’s micro display counter Seven-digit micro adding cRU us certified possibilities is perfect for 12 Vdc counter ● CE marked ● applications where small size ● Flush mount with High shock resistance 1 is important. integrated spring clip ● Low power consumption; ● Protection IP65 suitable for battery 1 ● consumption Stores value also at power ● failure Small dimensions 1 ● ● Long service life Large optical figures 1 Product Selection 1 Micro Display Counter Micro Display Counter 1 Description Catalog Number Micro display counter 7-Y-3013PM-401 1 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Electrical connections Built-in counter, flying leads, AWG 22, approx. 5.9 in (150 mm) 1 Power consumption At 68°F (20°C) and nominal voltage At 25 lmp/s: approx. 250 mW 1 Rated voltage 12 Vdc ±10% Counting frequency 25 lmp/s 1 Pulse duration Min. 20 ms Pulse interval Min. 20 ms 1 Cycle duration factor 100% 1 Number of digits 7 Counting system Adding 1 Figure size 0.05 x 0.16 in (1.2 x 4 mm) high optical Color of figures White-on-black 1 Reset No reset Ambient temperature 14° to 140°F (–10° to 60°C) 1 Mounting position Any 6 1 Operating Life >50 x 10 pulses Protection IP65 (only front side) 1 Housing Clear plastic Weight 0.53–0.71 oz (15–18g) 1 1 1 1 1 1 1 V13-T1-30 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 Micro Display Counter 0.08 (2) 1 0.04 (1.1) R 0.02 (0.5) max 1 1.26 (32) 0.51 x 1.18 (13 x 29.9) 1 0.59 (15) 1 +0.02 0.51 +0.01 0.12 (3) 1.18 +0.5 (13 ) +0.3 Max. 1 (30 ) 0.59 1.29 (15) (32.7) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-31 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers SE Series 1 Product Description Features Standards and Certifications ● ● Compact with various ● 1 Compact electromechanical Low-cost UL recognized mounting options counters. electromechanical counter ● ● Wire leads for electrical Multiple voltage ranges for 1 connections almost any application 1 1 Product Selection 1 SE Series Electromechanical Counters SE Series Counter— Electromechanical Order 1 Description Catalog Number Number Six-Digit Electric Counter 1 Bottom mount sub-miniature 12 Vdc 6-Y-41610-401-SE 41610401 Bottom mount sub-miniature 24 Vdc 6-Y-41610-402-SE 41610402 1 Bottom mount sub-miniature 120 Vac 6-Y-41610-406-SE 41610406 1 Bottom mount sub-miniature 240 Vac 6-Y-41610-407-SE 41610407 Base mount sub-miniature 12 Vdc 6-Y-41611-401-SE 41611401 1 Base mount sub-miniature 24 Vdc 6-Y-41611-402-SE 41611402 Base mount sub-miniature 120 Vac 6-Y-41611-406-SE 41611406 1 Base mount sub-miniature 240 Vac 6-Y-41611-407-SE 41611407 Panel mount sub-miniature 12 Vdc 6-Y-41613-401-SE 41613401 1 Panel mount sub-miniature 24 Vdc 6-Y-41613-402-SE 41613402 1 Panel mount sub-miniature 120 Vac 6-Y-41613-406-SE 41613406 Panel mount sub-miniature 240 Vac 6-Y-41613-407-SE 41613407 1 Special base mount sub-miniature 12 Vdc 6-Y-41622-401-SE 41622401 Special base mount sub-miniature 24 Vdc 6-Y-41622-402-SE; 41622402 1 Special base mount sub-miniature 120 Vac 6-Y-41622-406-SE 41622406 1 Special top mount sub-miniature 12 Vdc 6-Y-41623-401-SE 41623401 Special top mount sub-miniature 24 Vdc 6-Y-41623-402-SE 41623402 1 Special top mount sub-miniature 120 Vac 6-Y-41623-406-SE 41623406 Special top mount sub-miniature 240 Vac 6-Y-41623-407-SE 41623407 1 Snap-in mount sub-miniature 12 Vdc 6-Y-42613-401-SE 42613401 Snap-in mount sub-miniature 24 Vdc 6-Y-42613-402-SE 42613402 1 Snap-in mount sub-miniature 120 Vac 6-Y-42613-406-SE 42613406 1 Snap-in mount sub-miniature 240 Vac 6-Y-42613-407-SE 42613407 1 1 1 1 1 1 1 1 1 V13-T1-32 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 6 1 Count speed 600 cpm 1 Figure size 5/32 in (4.0 mm) Reset None 1 Mounting Base, bottom, top, panel or snap-in Finish Black, self-extinguishing plastic 1 Power requirements DC: 1.5W, AC: 5.0V 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 SE Series 1 Bottom Mount Base Mount Top Mount Panel Mount 1 1.01 1.00 0.69 0.88 1.52 Mounting Holes (2) #4-40 (25.7) (25.4) (17.4) (22.2) (38.7) for #6 FHMS Mounting 1.0 1 Holes (25.4) 1.80 1.31 1.00 (45.7) (33.2) 1.88 1.31 (25.4) (4) 0.13 (3.2) Dia. 1 (47.6) (33.2) 2.19 Mounting Holes 2.16 (55.5) 10 (54.9) 1 (254) 2.16 2.16 10 2.16 10 (54.9) (54.9) 0.63 (254) 10 (54.9) (254) 1 (15.9) (254) Panel Cutout 1.43 x 1.13 1 0.19 (36.3 x 28.6) (4.7) (2) #4-40 UNC 28 1 Special Base Mount Special Top Mount Snap Mount 1 1.50 1.00 (2) #4-40 (38.1) 0.14 (3.6) Dia. (25.4) 1 Mounting Holes 1.06 (26.9) 1.75 2.34 1.81 1.97 1 1.44 (44.5)(59.5) (46.0) (50) 1.31 (36.5) (33.2) 1 1.13 2.16 (28.6) 10 (54.9) 2.16 1 (254) 10 (54.9) 2.16 (254) Panel Cutout (54.9) 10 1 1.70 x 1.33 (254) (43.2 x 33.8) 1 0.19 (4.7) 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-33 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers MF Series 1 Product Description combined with a simplified, 1 Model MF Series are shaded hinged escapement drive, pole electric counters with also eliminates the possibility straight AC operation and 1 of miscounts and greatly feature a non-rectified, adds to the life of the shaded pole coil designed to 1 counter. Tallies at speeds withstand transient, high up to 750 cpm. voltage spikes. This feature, 1 Product Selection 1 MF Series Electric Counters MF Series Electric 1 Counter No. of Order Figures Voltage Reset Mounting Catalog Number Number 1 1 7 120 Vac Knob Base 7-Y-1-MF-120A 32650400 1 6 120 Vac Knob Base 6-Y-1-MF-120A 32651400 1 1 7 120 Vac Knob Panel 7-Y-1-MF-PM-120A 32652400 1 1 7 120 Vac Non-reset Panel 7-Y-13-MF-PM-120A 32652402 1 6 120 Vac Knob Panel 6-Y-1-MF-PM-120A 32653400 1 1 6 120 Vac Non-reset Panel 6-Y-13-MF-PM-120A 32653405 1 6 120 Vac Keylock reset Panel 6-Y-12-MF-PM-120A 32654400 1 6 24 Vac Keylock reset Panel 6-Y-12-MF-PM-24A 32654403 1 7 120 Vac Keylock reset Panel 7-Y-12-MF-PM-120A 32655400 1 1 6 120 Vac Non-reset Base 6-Y-13-MF-120A 32658400 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Figures 6 or 7 Speed Up to 750 cpm 1 Figure size 3/16 in (4.8 mm) high, white-on-black background Reset Knob, key or non-reset 1 Mounting Base or panel mount 1 Finish Black frame and side covers 2 Electrical connections Two-wire leads, 9 in (229 mm) long, AWG 22 (0.34 mm ), stripped 0.38 in (9.5 mm) 1 Power requirements 12 watts Coils Various AC voltages and frequencies can be supplied on special order. 1 Count coils are designed for continuous duty at rated voltage. 1 Note 1 UL Recognized. 1 1 1 1 1 1 1 V13-T1-34 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 MF Series 1 Panel Mounted Panel Mounted with Tumbler Lock 4.37 (111.1) 5.50 (139.7) 1 0.12 0.19 0.19 (4.8) 4.00 (101.6) 5.12 (130.2) 0.19 (3.0) (4.8) (4.8) AB CD 1 0.30 (7.5) 0.16 1.75 2.12 1.25 1.62 1 (4.0) (44.5) (54.0) (31.8) (41.3) 1 0.97 (24.6) #6-32 T op Mount Dia. 0.15 (3.81) Dia. 0.15 (3.81) Models Only 0.06 4 Mtg. Holes 1 4 Mtg. Holes 4 Mtg. Holes (1.6) 1 1.25 0.09 Panel 2.56 Panel (31.8) 2.56 (2.4) (65.0) 2.09 1 (65.0) (53.1) 1 3.68 (93.5) 0.62 0.56 0.25 (15.7) 2.56 (65.0) 4.62 x 1.44 (117.3 x 36.5) Panel Opening 1 (14.2) (6.3) 3.68 (93.5) 3.51 x 1.44 (89.3 x 36.5) Panel Opening 1 1 Base Mounted 1 3.31 (84.1) 0.28 E F (7.1) 1 0.87 1.37 (22.2) (34.9) 1 Dia. 0.14 (3.6) 4 Mtg. Holes 1 1 0.41 3.16 (80.2) (10.3) 1 2.56 (65.0) 0.25 2.09 1 (6.3) (53.1) 1 0.62 0.56 2.56 (65.0) (15.7) (14.2) 1 3.68 (93.5) 1 Model ABC DE F 1 Six figures 1.73 (44.0) 1.58 (40.0) 1.73 (43.9) 2.80 (71.1) 1.73 (44.0) 1.12 (28.6) Seven figures 2.02 (51.4) 1.29 (32.7) 2.03 (51.6) 2.50 (63.5) 2.02 (51.4) 0.84 (21.2) 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-35 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers RMF Series 1 Product Description built-in higher capacity continues to operate 1 Model RMF Series of electric rectifier for AC operation. The dependably even when counters are designed to give counter has a minimum of subject to severe shock and accurate counts through a 1 moving parts that never need vibrations. Entirely enclosed wide range of speeds up to lubrication under normal to prevent damage from 1000 cpm. It features a 1 operating conditions. moisture and dust. Available strong, silent, fast operating Compact and rigid, it in 6 or 7 figures. DC electromagnetic drive 1 with a compact, dependable 1 Product Selection When Ordering Specify 1 ● To determine a model Number of figures number from the Product ● Voltage 1 Selection table for Model ● Type of reset RMF Series Electronic ● Type of mounting 1 Counters, consider: RMF Series Electromechanical Counters 1 RMF Series Counter— Electromechanical No. of Order Figures Voltage Reset Mounting Catalog Number Number 1 6 24 Vdc Knob Panel 6-Y-1-RMF-PM-24D 31013400 1 7 24 Vdc Knob Panel 7-Y-1-RMF-PM-24D 31019400 1 7 115 Vac Knob Base 7-Y-1-RMF-115A 31025400 1 1 7 115 Vac Non-reset Base 7-Y-13-RMF-115A 31026400 1 7 115 Vac Knob Panel 7-Y-1-RMF-PM-115A 31026401 1 1 7 115 Vac Non-reset Panel 7-Y-13-RMF-PM-115A 31026402 1 6 115 Vac Non-reset Base 6-Y-13-RMF-115A 31039400 1 6 230 Vac Knob Panel 6-Y-1-RMF-PM-230A 31066413 1 1 6 115 Vac Knob Panel 6-Y-1-RMF-PM-115A 31066416 1 6 115 Vac Keylock reset Panel 6-Y-12-RMF-PM-115A 31083403 1 6 230 Vac Keylock reset Panel 6-Y-12-RMF-PM-230A 31083405 1 7 115 Vac Keylock reset Panel 7-Y-12-RMF-PM-115A 31083409 1 6 24 Vac Keylock reset Panel 6-Y-12-RMF-PM-24A 31083411 6 24 Vdc Keylock reset Panel 6-Y-12-RMF-PM-24D 31083415 1 7 24 Vdc Keylock reset Panel 7-Y-12-RMF-PM-24D 31083421 1 7 230 Vac Keylock reset Panel 7-Y-12-RMF-PM-230A 31083427 6 24 Vac Knob Base 6-Y-1-RMF-24A 31155400 1 6 240 Vac Knob Base 6-Y-1-RMF-240A 31155401 1 6 115 Vac Knob Base 6-Y-1-RMF-115A 31155402 1 1 6 115 Vac Non-reset Panel 6-Y-13-RMF-PM-115A 31155405 7 24 Vdc Non-reset Panel 7-Y-13-RMF-PM-24D 33183400 1 Note 1 1 UL recognized. 1 1 1 1 1 1 V13-T1-36 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Figures 6 or 7 1 Speed Up to 1000 cpm 1 Figure size 3/16 in (4.8 mm) high, white-on-black background Reset Knob, key or non-reset 1 Mounting Base or panel mount Finish Black frame and side covers 1 2 Electrical connections Two-wire leads, 9 in (229 mm) long, AWG 22 (0.34 mm ), stripped 0.38 in (9.5 mm) Power requirements 7 watts 1 Coils Various voltages and frequencies can be supplied on special order. Count coils are designed for continuous duty at rated voltage 1 1 Dimensions Refer to table and illustrations 1 on Page V13-T1-35 for information. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-37 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers ME Series 1 Product Description Standards and Certifications models measuring only 1 x reliable, long life operation. ● 1 Small in size and price, but UL recognized 1.593 x 2.187 in (25.4 x 40.5 x Designed for mounting large in design versatility and 55.5 mm) and weighing just flexibility and aesthetic model variety is the ME 1 three ounces (85 grams). attractiveness, the miniature Series of miniature electric electric counters are available counters. Models in most 1 Available in 4, 6 or 7 figures, with three types of mounting popular AC or DC voltages the counters feature stainless and a glare retarding finish operate on as little as 3 steel self-lubricating shafts, 1 Delrin, with crisp easy-to-read watts, with the non-reset nylatron pinions and a numerals set close to a synchronous electromagnetic tamper-proof sealed figure 1 drive to assure accurate, window. 1 1 Product Selection When Ordering Specify 1 When ordering ME Series Bottom Mount Wire Leads Base Mount Wire Leads Panel Mount Wire Leads Miniature Electric Counters, 1 specify catalog numbers according to the features 1 selected. 1 1 1 ME Series Miniature Electric Counters ME Series Miniature Electric Counter No. of Order 1 Figures Voltage Reset Mounting Catalog Number Number 4 12 Vdc Pushbutton Bottom 4-Y-41312-401-MEQ 41312401 1 4 24 Vdc Pushbutton Bottom 4-Y-41312-402-MEQ 41312402 1 4 120 Vac Pushbutton Bottom 4-Y-41312-406-MEQ 41312406 4 24 Vdc Pushbutton Base 4-Y-41313-402-MEQ 41313402 1 4 120 Vac Pushbutton Base 4-Y-41313-406-MEQ 41313406 4 240 Vac Pushbutton Base 4-Y-41313-407-MEQ 41313407 1 4 12 Vdc Pushbutton Panel 4-Y-41314-401-MEQ 41314401 4 24 Vdc Pushbutton Panel 4-Y-41314-402-MEQ 41314402 1 4 120 Vac Pushbutton Panel 4-Y-41314-406-MEQ 41314406 1 4 240 Vac Pushbutton Panel 4-Y-41314-407-MEQ 41314407 1 1 1 1 1 1 1 1 1 V13-T1-38 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers ME Series Miniature Electric Counters, continued ME Series Miniature 1 Electric Counter No. of Order Figures Voltage Reset Mounting Catalog Number Number 1 6 24 Vdc Non-reset Bottom 6-Y-41119-402-ME 41119402 6 120 Vac Non-reset Bottom 6-Y-41119-406-ME 41119406 1 6 12 Vdc Non-reset Base 6-Y-41345-401-ME 41345401 6 24 Vdc Non-reset Base 6-Y-41345-402-ME 41345402 1 6 120 Vac Non-reset Base 6-Y-41345-406-ME 41345406 1 6 240 Vac Non-reset Base 6-Y-41345-407-ME 41345407 6 12 Vdc Non-reset Panel 6-Y-41346-401-ME 41346401 1 6 24 Vdc Non-reset Panel 6-Y-41346-402-ME 41346402 6 120 Vac Non-reset Panel 6-Y-41346-406-ME 41346406 1 6 240 Vac Non-reset Panel 6-Y-41346-407-ME 41346407 7 12 Vdc Non-reset Bottom 7-Y-41238-401-ME 41238401 1 7 24 Vdc Non-reset Bottom 7-Y-41238-402-ME 41238402 1 7 120 Vac Non-reset Bottom 7-Y-41238-406-ME 41238406 7 12 Vdc Non-reset Base 7-Y-41337-401-ME 41337401 1 7 24 Vdc Non-reset Base 7-Y-41337-402-ME 41337402 7 120 Vac Non-reset Base 7-Y-41337-406-ME 41337406 1 7 12 Vdc Non-reset Panel 7-Y-41349-401-ME 41349401 1 7 24 Vdc Non-reset Panel 7-Y-41349-402-ME 41349402 7 120 Vac Non-reset Panel 7-Y-41349-406-ME 41349406 1 7 240 Vac Non-reset Panel 7-Y-41349-407-ME 41349407 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Figures 4, 6 and 7 Speed Up to 1000 cpm 1 Figure size 3/16 in (4.8 mm) high 1 Reset Pushbutton and non-reset Reset force Pushbutton models only, 20 oz. (568 grams) maximum 1 Mounting Base, bottom, panel Finish Black self-extinguishing plastic 1 Electrical connections Wire leads, 10 in (254 mm) long, AWG 20, stripped 3/8 in (9.5 mm), and pin terminals 1 Power requirements 3W Coils Count coils are designed for continuous duty at rated voltage 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-39 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 ME Series Counters 1 Panel Mounted Bottom Mounted 1 1 1 1 1 1 1 1 Base Mounted Bottom Mounted 1 1 1 1 1 1 1 ME Series Counters Recommended Panel Mount Cut-Outs 4 Figure Pushbutton Reset Counters 6 and 7 Figure Non-Reset Counters 4 Figure Counters 6 and 7 Figure Counters 1 Dimension Inches (mm) Dimension Inches (mm) Pushbutton Reset Non-Reset 1 A 1.00 (25.4) A 1.00 (25.4) 1.72 x 1.11 (43.7 x 28.2) 1.72 x 1.11 (43.7 x 28.2) B 1.60 (40.6) B 1.60 (40.6) 1 C 2.64 (67.1) C 2.38 (60.5) D 2.19 (55.6) D 2.19 (55.6) 1 E 1.80 (45.7) E 1.80 (45.7) F 1.80 (45.7) F 1.80 (45.7) 1 G 1.40 (35.6) G 1.40 (35.6) 1 H 0.69 (17.5) H 0.69 (17.5) J 1.88 (47.8) J 1.88 (47.8) 1 K 0.50 (12.7) K 0.50 (12.7) L 0.49 (12.4) L 0.49 (12.4) 1 M 0.94 (23.9) M 0.94 (23.9) 1 N 2.45 (62.2) N 2.19 (55.6) P 2.45 (62.2) P 2.19 (55.6) 1 Q 0.45 (11.4) Q 0.45 (11.4) R 0.63 (16.0) R 0.63 (16.0) 1 S 0.19 (4.8) S 0.19 (4.8) T 0.68 (17.3) T 0.88 (22.4) 1 V13-T1-40 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Contents Electronic Totalizers 1 Description Page Mechanical Totalizers 1 Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-5 Revolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-14 1 Electromechanical Totalizers . . . . . . . . . . . . . . . . . V13-T1-29 1 Electronic Totalizers 1/32 DIN LCD Totalizers . . . . . . . . . . . . . . . . . . V13-T1-42 1 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter . . . . . . . . . . . . . . . V13-T1-44 1 Courier Series . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-46 1/8 DIN LED Multifunction 1 Totalizer/Timer/Ratemeter . . . . . . . . . . . . . . . V13-T1-49 1 1 1 1 Electronic Totalizers Product Overview Features Standards and Certifications 1 ● ● Eaton’s electric totalizers LED and LCD readouts Most products are UL provide a flexible and certified (see individual ● Variety of sizes and 1 accurate method of product pages for details) packages displaying count and ● CE ● Programmable inputs and 1 measurement data in an displays available easily readable format. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-41 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers 1/32 DIN LCD Totalizers 1 Product Description Features Standards and Certifications ● ● Screw terminals, RM ● 1 Compact battery powered Low price and high UL recognized 5mm totalizers where AC power is efficiency ● CE marked ● unavailable. ● Lifetime of the battery Large eight-digit LCD 1 approximately eight years display, height of the ● figures 0.31 in (8 mm) Locking of the reset key 1 ● ● Various counting modes Operating temperature like up/down differential 14° to 140°F (–10° to 60°C) 1 available ● All version of positive or ● High voltage input for negative counting edge 1 10–260 Vac/Vdc voltage ● Filter function for bounce- pulses free counting with 1 ● IP65 mechanical contacts 1 1 Product Selection 1 1/32 DIN LCD Totalizers E5-024-C04_ Description Catalog Number 1 Eight-Digit LCD Totalizer, Battery Power 4–30 Vdc powered, NPN/PNP 0.94 x 1.89 in (24 x 48 mm) E5-024-C0400 1 10–120V input AC/DC powered, NPN only 0.94 x 1.89 in (24 x 48 mm) E5-024-C0408 Count up/down 4–30 Vdc powered, NPN only, 0.94 x 1.89 in (24 x 48 mm) E5-024-C0410 1 1 Technical Data and Specifications 1 1/32 DIN LCD Totalizers 1 Description Specification Power supply Non-replaceable lithium battery (lifetime approximately eight years at 68°F (20°C) 1 Display LCD, eight-digits 1 Figure size 0.31 in (8 mm) high Mode Adding or subtracting (selectable), counting direction, differential counting or phase 1 discriminator single or dual evaluation (selectable) Display range –9999999 to 99999999, with overflow display 1 Reset Manual and electrical Interference emissions EN 55011 Class B, EN 61 000-6-2, EN 61010 Section 1 (only AC versions) 1 Housing Dark gray RAL 7021 Operating temperature 14° to 131°F (–10° to 55°C) 1 Ambient temperature 14° to 140°F (–10° to 60°C) 1 Storage temperature –4° to 158°F (–20° to 70°C) Protection IP65 (from front) 1 Weight Approx. 1.76 oz (50g) 1 1 1 1 1 1 V13-T1-42 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers 1/32 DIN LCD Totalizers, continued 1 Description Specification Counting inputs: 1 Counting input of the DC version Max. 30 Vdc Slow counting input Max. 30 Hz (NPN) 1 Fast counting input Max. 12 kHz (PNP) 1 Switching level NPN: Low 0–0.7V, High 3–30 Vdc PNP: Low 0–0.7V, High 3–30 Vdc 1 Counting Input of the high voltage versions 10–260 Vac/Vdc Counting input Optocoupler input, max. 30 Hz 1 Min. pulse time 16 ms Switching level Low: 0–2 Vac/Vdc 1 High: 10–260 Vac/Vdc Counting direction switching (only DC versions) Contact input, open collector NPN (switching at 0 Vdc) 1 Switching level, NPN—Low, 0–0.7V, High 3–5 Vdc 1 Reset input (only DC and high voltage)— Minimum pulse time DC: 50 ms; high voltage: 16 ms 1 Contact input NPN Low: 0–0.7V High: 3–30 Vdc 1 High voltage input 10–260 Vac/Vdc Electrical reset key locking (for DC and AC) Contact input, open collector NPN (switching at 0V) 1 Switching level, NPN—Low, 0–0.7V, High 3–5 Vdc 1 1 Dimensions Approximate Dimensions in Inches (mm) 1 1/32 DIN LCD Totalizers 1 MAX. 1.89 (19.3) 1.89 (48) 1 0.87 x 1.77 0.94 1 (22 x 45) (24) 1 0.11 (2.8) 1.88 (47.7) 0.12 (3) 1 + 0.024 1 1.77 + 0.6 (45 ) 1 + 0.012 1.77 +0.3 (22.2 ) 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-43 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter 1 Product Description Features Standards and Certifications ● ● Timer ● 1 Compact LED display for a Display counter adding and UL recognized ● variety of input signals. subtracting Display range: –199.999 to ● CE marked ● 999.999 with zero blanking Position display 1 ● ● Screw terminal Frequency counter/ ● ratemeter 1 Locking SET-key 1 Product Selection 1 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter E5-024-C04_ 1 Description Catalog Number LED Single channel totalizer, 10–30 Vdc power E5-024-E0402 1 0.94 x 1.89 in (24 x 48 mm) LED multifunction totalizer/timer/ratemeter 10–30 Vdc power E5-424-E0402 1 0.94 x 1.89 in (24 x 48 mm) LED double-function totalizer/timer/ratemeter 10–30 Vdc power E5-524-E0402 1 0.94 x 1.89 in (24 x 48 mm) LED totalizer with quadrature, 10–30 Vdc power E5-024-E0432 1 0.94 x 1.89 in (24 x 48 mm) 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Supply voltage 10–30 Vdc with reverse polarity protection 1 Current consumption Max. 55 mA 1 Display Six-digit red, seven-segment LED display Figure size 0.31 in (8 mm) high 1 Data backup EEPROM Housing Dimension 3.78 x 1.89 in (48 x 24 mm) according to DIN 43 700; RAL 7021 gray 1 Polarity of inputs Programmable, NPN or PNP 1 Input resistance Approx. 10k ohms Counting frequency 60 kHz, can be damped to 30 Hz, position display max. 25 kHz 1 Resolution Timer 0.001 sec. Reset time 5 ms 1 Level of inputs High 0.6 x U –30 Vdc B 1 Low 0–0.2 x U (Vdc) B Error 1 Tachometer <0.1% 1 Timer <50 ppm Ambient temperature 4° to 131°F (–20° to 55°C) 1 Storage temperature –13° to 167°F (–25° to 75°C) EMC According to EC EMC directive 89/36/EWG 1 Immunity to interference EN 61 000-6-4/ EN 55011 Class B Emitted interference EN 61 000-6-2 1 Protection IP65 (from front) 1 Weight Approx. 5.29 oz (150g) 1 1 V13-T1-44 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter 0.87 x 1.77 Max. 0.76 1 1.89 (22.0 x 45.0) (19.3) Connections: (48.0) 1 0.94 (24.0) 1 Panel Cut-Out: 1 0.16 + 0.01 + 0.02 0.87 x 1.77 (4.0) + 0.3 + 0.6 (22.2 x 45 ) 0.26 1 2.32 (6.5) (59.0) 1 + 0.02 2.09 1.97 + 0.6 1 (53.0) (50 ) 1 + 0.02 1.10 0.98 x 1.97 0.98 + 0.5 (28.0) (25 x 50) (25 ) 1 1 0.04 Panel Cut-Out (1.0) 0.16 1 (4.0) 1 + 0.02 2.20 1.97 + 0.6 (56.0) (50 ) 1 1 + 0.004 1.57 1.26 0.98 x 1.97 + 0.02 1.26 0.98 + 0.1 (40) (32) (25 x 50) + 0.5 (32 ) (25 ) 1 0.04 M3 1 (1.0) Panel Cut-Out 0.16 (4.0) 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-45 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Courier Series 1 Product Description Features Standards and Certifications ● ● 0.43 in (10.9 mm) display ● 1 Eaton’s Courier Series is a Eight-digit totalizer CE marked ● high quality totalizer powered ● Front panel reset 1/Tau ratemeter by a replaceable lithium ● 1 ● NEMA 4X Scaling capabilities battery. ● Remote reset terminal 1 1 Product Selection 1 When Ordering Specify When ordering Courier Series 1 Electronic Totalizers and Ratemeters, specify order 1 numbers according to the features selected. 1 Courier Series, Eight-Digit LCD Courier Series 1 Description Catalog Number Totalizer, battery 53300400 1 Add/subtract (10k Hz, PNP input) totalizer, battery 53300401 1 Add/subtract (20 Hz, NPN/contact input) totalizer, battery 53300402 Quadrature (10k Hz, PNP input) totalizer, battery 53300403 1 Totalizer/ratemeter, battery 53300405 Totalizer/ratemeter at 100 Hz, battery 53300465 1 RMF panel mount totalizer, key reset, 60–160 Vac/Vdc count input 53300800 RMF panel mount totalizer, dry contact input 53300850 1 RMF panel mount totalizer, 60–160 Vac/Vdc count input 53300851 1 Totalizer—extended temperature range, battery 53301400 Totalizer—1/Tau ratemeter—extended temperature range 53301404 1 Totalizer/ratemeter—extended temperature range, battery 53301405 Totalizer/ratemeter, mag pickup, battery 53301475 1 Backlight totalizer, battery 53302400 Backlight add/subtract (10k Hz, PNP input) totalizer, battery 53302401 1 Backlight add/subtract (20 Hz, NPN/contact input) totalizer, battery 53302402 1 Backlight quadrature (10k Hz, PNP input) totalizer, battery 53302403 Backlight totalizer/ratemeter, battery 53302405 1 1 1 1 1 1 1 1 1 1 V13-T1-46 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Technical Data and Specifications 1 General Specifications Description Specification 1 Power Internal battery 3V, lithium 1 Life expectancy 5 years + 1 Replacement part 36367-202 Backlight 1 1 Backlight 10–30 Vdc at 30 mA max. Reverse polarity protected 1 Physical Operating temperature –4° to 158°F (–20° to 70°C) 1 Storage temperature –4° to 158°F (–20° to 70°C) Operating humidity 60% non-condensing 1 Weight 2.2 oz (62g) net Figure size 0.43 in (10.9 mm) high 1 Front panel rating NEMA 4X when mounted with gasket provided Case material Cycolac X-17 1 Totalizer Type UP counting 1 Digits Eight Count Accuracy 1 Operated within specifications 100% DC Common (Terminal 1) Count Inputs 1 Input B (terminal 2) low speed input designed for contact closures to DC common 1 Speed 0 to 20 Hz Min. low time 10 ms 1 Min. high time 40 ms Input impedance 101k ohms 1 Voltage thresholds Low 0–0.4 Vdc 1 High 2.0–28 Vdc Max. high 28 Vdc 1 Input A (terminal 3) high speed input requiring a voltage source such as a current sourcing sensor or a current sinking sensor used with 1 the provided pull up resistors Speed 0 to 10 kHz 2 Min. low time 80 ms 1 2 Min. high time 20 ms Input impedance 2k ohms above 5 Vdc 1 Voltage thresholds Low 0–1.2 Vdc 1 High 2.0–28 Vdc Max. high 28 Vdc 1 Reset Input 1 Reset input (terminal 4) designed for contact closures to DC common 3 Min. low 0.25 to 1 sec. (reset is maintained) 1 Voltage thresholds Low 0–0.4 Vdc 1 High 2.0–28 Vdc Front Panel Reset Enable 1 Front panel reset enable (terminal 5) Operation Level sensitive (maintained) 1 Notes 1 1 Derate operating temperature 1°C/volt above 17 Vdc. 2 The times are with a 0–5.0V swing. 3 The required pulse width varies with count speed, scale factor and number of digits displayed. 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-47 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 Courier Series 1.25 1 (31.8) 1 1 1 1 2.95 (74.9) 2.67 (67.8) 1 1 1.57 1.30 Recommended (39.9) (33.0) Panel Cutout 1 T/R RST 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-48 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter 1 Product Description Features Standards and Certifications ● ● Programmable mode ● LED display for a variety of Display counter adding and UL recognized 1 ● input signals. subtracting Display range: –199.999 to ● CE marked ● 999.999 with zero blanking Position display 1 ● ● Connection with screw Frequency counter/ terminal ratemeter 1 ● ● Locking SET-key for reset Timer, res. up to 0.001 second 1 1 Product Selection 1 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter E5-496-E040_ 1 Description Catalog Number LED Multifunction Counter/Timer/Ratemeter 1 90–260 Vac power 3.78 x 1.89 in (96 x 48 mm) E5-496-E0401 10–30 Vdc power 3.78 x 1.89 in (96 x 48 mm) E5-496-E0402 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Supply voltage 10–30 Vdc with reverse polarity protection; 90–260 Vac 1 Current consumption Max. 50 mA 6 VA Display Six-digit red, seven-segment LED display 1 Figure size 0.55 in (14 mm) high 1 Data backup EEPROM Housing Dimension 3.78 x 1.89 in (96 x 48 mm) according to DIN 43 700; RAL 7021 gray 1 Polarity of inputs Programmable, NPN or PNP for all inputs Input resistance Approx. 10k ohms 1 Counting frequency 60 kHz, can be damped to 30 Hz depending on operating mode at position display 1 max. 25 kHz 1 Reset time 5 ms Resolution timer Up to 0.001 second 1 Input switching level DC version (standard version) High: 0.6 x U –30 Vdc B 1 Low: 0–0.2 x U (Vdc) B 1 AC version High: 12–30 Vdc Low: 0–4 Vdc 1 Voltage supply for sensors 24 Vdc ±15%/100 mA at AC versions Accuracy 1 Tachometer <0.1% Timer <50 ppm 1 Ambient temperature –4° to 149°F (–20° to 65°C) 1 Storage temperature –13° to 167°F (–25° to 75°C) EMC According to EC EMC directive 89/36/EWG 1 Immunity to interference EN 61 000-6-4/ EN 55011 Class B Emitted interference EN 61-000-6-2 1 Protection IP65 (from front) Weight Approx. 5.29 oz (150g) 1 Note 1 1 For further specifications, please refer to the user manual. Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-49 Counters, Panel Meters, Tachometers and Timers 1.1 Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter Max. 0.75 1 (19.0) 3.78 (96.0) 1 1 1.89 1.77 x 3.62 (48.0) (44.9 x 91.9) 1 1 1 0.16 0.61 (4.0) (15.5) 0.26 1 (6.5) 2.64 +0.02 1.77 (67.1) 1 +0.6 (45.0 ) 1 +0.03 3.62 1 +0.8 (92.0 ) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-50 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Contents Count Controls/Preset Counters 1 Description Page Count Controls/Preset Counters 1 Product Selection Guide . . . . . . . . . . . . . . . . . . . . V13-T1-52 1/16 DIN Battery Powered LCD 1 Count Control . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-53 1/16 DIN LCD Preset Counters with Rate 1 and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-55 Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-57 1 President Series (Totalizers). . . . . . . . . . . . . . . . . . V13-T1-60 Ambassador Series (Totalizers) . . . . . . . . . . . . . . . V13-T1-69 1 Ambassador Series (Count Control) . . . . . . . . . . . V13-T1-72 1 President Series (Count Control) . . . . . . . . . . . . . . V13-T1-64 PD-Q and PD-ER Series . . . . . . . . . . . . . . . . . . . . V13-T1-76 1 Learn Online 1 1 1 Product Overview Count controls are counters Application Example 1 that provide output signal(s) Rotary Contactor at preset count value(s). 1 Typical applications include cut-to-length, batching, filling, mixing and dispensing. A 1 variety of count controls in different sizes, display types 1 and feature sets are available from Eaton. 1 Paper Application Description 1 The illustration shows a Measuring simple cut-to-length 1 Wheel application. The roll of paper Roll is measured using a 1 measuring wheel and rotary contactor (or encoder). Once 1 the desired length is reached, an output signal may be directed to a shear for 1 activation. Following the cut- off, the count control will 1 reset to zero and begin measurement of the next 1 piece. Options such as batch counting, where the number 1 of cut pieces is counted, are also typical of this application. 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-51 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Product Selection Guide 1 Count Controls/Preset Counters/Totalizers 1 Panel Cutout Characteristics in Inches (mm) Page 1 E5-148-C Low cost, simple count control 1.772 x 1.772 V13-T1-53 (45 x 45) Battery operated 1 Easy-to-change preset values Two-line display: input and preset values 1 1 E5-648-C Two-line display: counter, timer or tachometer 1.772 x 1.772 V13-T1-55 (45 x 45) AC or DC power options 1 Wide choice of count modes for pulse inputs, time or frequency Two or four presets 1 1 Eclipse Six-digit, super bright LED display 1.772 x 3.780 V13-T1-57 1 (45 x 96) Multiple models available: totalizers, ratemeters, count controls, digital panel meters and flow controls 1 1 Ambassador Six-digit, high-visibility, two-line LCD display 2.667 x 2.667 V13-T1-72 1 (68 x 68) User-configurable control inputs Highly flexible control/display 1 1 President Bright LED display with 14 mm characters 2.667 x 5.433 V13-T1-64 1 (68 x 138) Simple configuration with 14-button tactile keypad 1 Many different versions fit almost any application 1 PD-Q and PD-ER Electromechanical pre-set counter 272 x 1.59 V13-T1-76 1 (69 x 40.5) Easy setpoint adjustment using pushbuttons (panel mount model) Base mount or panel mount 1 1 1 Fusion Integrated controller combines operator interface, ladder logic and 2.667 x 5.433 V13-T1-119 high-speed counting (68 x 138) 1 1 1 1 1 1 1 1 V13-T1-52 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers 1/16 DIN Battery Powered LCD Count Control 1 Product Description Features Standards and Certifications ® ● ● ● Battery-powered electronic Replacement for Screw terminal cRU us approval 1 preset counter. electromechanical preset ● ● Data security, through two CE marked counters exchangeable lithium 1 ● No power supply batteries, lifetime necessary (battery minimum eight years 1 operated) ● Easy programming ● Count and reset input ● Counter presets easily via 1 electrically separated from presetting keys allocated counter through to each decade 1 optocoupler input range ● Output: Potential free 12–250 Vac/Vdc relay, programmable 1 ● Two-line LC display count, normally open or normally preset and level of the closed contact output 1 1 Product Selection 1 1/16 DIN Battery Powered LCD Count Control E5-148-C1400 1 Description Catalog Number Single Preset Count Control 1 Battery power 1.89 x 1.89 in (48 x 48 mm) E5-148-C1400 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Power supply 2 pcs user exchangeable lithium batteries, type 1/2 AA lithium 3.6V 1 Display Two-line LCD display, six digits; 999999 Figure size 0.28 in (7 mm) or 0.18 in (4.5 mm) high 1 Input Reset, count and keylock inputs Input polarity Bi-directional optocoupler input for the reset count inputs; 1 reset, count and keyboard lock is connected to 3 Vdc Input min. pulse duration Reset input 50 ms; keyboard lock input 15 ms 1 Input switching levels Low <3 Vac/Vdc 1 High 12–250 Vac/Vdc Input frequency Max. 25 Hz 1 Input resistance 110k ohms 1 Output Bistable relay with potential free contact (programmable as normally closed or normally open contact) 1 Max. switching voltage 250 Vac/220 Vdc Max. switching current 2A 1 Max. switching capacity 60 VA/30W Output response time <20 ms, max. 4 Hz 1 6 Data retention Via two batteries, eight years or 5x10 power operations of the output relay and an ambient temperature of 77°F (25°C) 1 Ambient temperature 14° to 122°F (–10° to 50°C) Storage temperature –13° to 140°F (–25° to 60°C) 1 EMC According to EC EMC directive 89/36/EWG, EN 61 000-6-4/ EN 55011 Class B, EN 61 000-6-2 1 Protection IP65 (front) Weight Approx. 2.82 oz (80g) 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-53 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 1/16 DIN Battery Powered LCD Count Control 1 Max. 0.41 1.89 (10.5) (48.0) 1 123456 7 1.89 SQ 1.77 1 (48.0) (45) 123456 7 1 1 0.63 2.49 0.12 (16.0) (63.2) (3.0) Panel Cut-Out 1.77 x 1.77 (45 x 45) 1 1 2.17 Max. 0.37 (55.0) (9.5) 1 1 2.17 SQ 1.77 SQ 1.97 (55.0) (45) (50) 1 1 0.63 2.45 0.16 (16.0) (62.2) (4.0) 1 With Front Bezel No. 2 Panel Cut-Out 1.97 x 1.97 (50 x 50) 1 2.36 Max. 0.37 1 (60.0) (9.5) 1 1 2.95 2.48 SQ 1.77 SQ 1.97 (75.0) (63) (45) (50) 1 1 0.63 2.45 0.16 Flush Bf4, DIN 74 (16.0) (62.2) (4.0) 1 With Front Bezel No. 3 Panel Cut-Out 1.97 x 1.97 (50 x 50) 1 1 1 1 1 1 1 1 1 V13-T1-54 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers 1/16 DIN LCD Preset Counters with Rate and Time 1 Product Description Features Standards and Certifications ® ● ● ● AC or DC powered preset Two-line display with green Direct input of the presets cRU us approval 1 counters that can function as backlight (E5-648-C2421 via front keys or Teach-In ● CE marked timer or tachometer/ and E5-648-C2422) or input 1 ratemeter. multi-color red/green LED ● Relay outputs backlighting (E5-648- ● Scaling by multiplication 1 C4461 and E5-648-C4462) and division factors 0.0001 ● Programmable as preset to 99.999 1 counter, batch counter or ● Two preset values, two totalizer outputs 1 ● Power supply: 90–260 Vac ● Four preset values, four or 10–30 Vdc outputs 1 1 Product Selection 1 1/16 DIN Two-Line LCD Count Control E5-648-C_ Description Catalog Number 1 Two Preset LCD Count Control with Backlighting 90–260 Vac power 1.89 x 1.89 in (48 x 48 mm) E5-648-C2421 1 10–30 Vdc power 1.89 x 1.89 in (48 x 48 mm) E5-648-C2422 1 Four Preset LCD Count Control with Multi-Color Display 90–260 Vac power 1.89 x 1.89 in (48 x 48 mm) E5-648-C4461 1 1 10–30 Vdc power 1.89 x 1.89 in (48 x 48 mm) E5-648-C4462 1 Technical Data and Specifications 1 General Specifications 1 Description Specification 1 Power supply 10–30 Vdc external fuse protection 90–260 Vac max. 8 VA external fuse protection 1 Display Two-line LCD display, six digits with programmable decimal point Figure size 0.35 in (9 mm) high upper line 1 0.28 in (7 mm) high lower line Count inputs Two count inputs (A and B), programmable for count/count direction, up/up, up/down, 1 quadrature, quad2, quad4, A/B or (A-B)/A x 100% Input polarity Programmable for all inputs in common NPN/PNP 1 Input resistance Approx. 5k ohms 1 Count frequency Max. 55 kHz with programmable filter for 30 Hz (see manual for details) Input min. pulse duration 10 ms for control inputs/1 ms for reset input 1 Switching levels DC supply voltage 1 High 0.6 x UB–30 Vdc Low 0–0.2 x UB (Vdc) 1 AC supply voltage 1 High 12–30 Vdc Low 0–4 Vdc 1 Pulse shape Variable (Schmitt-Trigger characteristics) Note 1 1 Not a stocked product, contact Eaton Care for assistance. 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-55 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers General Specifications, continued 1 Description Specification Output 1 1 Relay Programmable as normally open or normally closed Switching voltage max. 250 Vac/110 Vdc 1 Switching current max. 3A Vac/3A Vdc 1 Switching current at DC min. 30 mA Vdc Switching power at DC 90W 1 Switching power at AC max. 750 VA Output 2 1 Relay Relay with changeover/Form C contact Switching voltage max. 250 Vac/110 Vdc 1 Switching current max. 3A Vac/3A Vdc 1 Switching current at DC min. 30 mA Vdc Switching power at DC 90W 1 Switching power at AC max. 750 VA Reaction time of the outputs Approximately 10 ms 1 Data retention Min. 10 years or 1 million memory cycles Sensor supply voltage 1 AC powered unit 24 Vdc ±15%, 80 mA 1 DC powered unit Max. 80 mA, DC voltage is connected through Ambient operating temperature –4° to 149°F (–20° to +65°C) 1 Storage temperature –13° to 167°F (–25° to 75°C) EMC 1 Emitted interference EN 55011 Class B Immunity to interference EN 61000-6-2 1 Protection IP65 (front) Weight Approx. 4.4 oz (125g) 1 1 Dimensions 1 Approximate Dimensions in mm [Inches] 1 1/16 DIN Two-Line LCD Count Control Max. 10.5 1 [0.413] 48 +06 45 1 [1.89] +0.024 [1.77 ] 1 1 48 45 +06 45 [1.89] [1.77] +0.024 [1.77 ] 1 1 15.5 [0.61] 1 Panel Cut-Out 4.25 [0.167] 1 7 [0.276] 91 [3.583] 1 1 1 V13-T1-56 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Eclipse Series 1 Product Description Features Standards and Certifications ● ● ● High visibility LED interface 1/8 DIN cutout Removable screw UL and cUL listed 1 available with a variety of terminals ● ● NEMA 4X front panel CE marked output options ● ● Short depth: 3.6 in (91 mm) 1 Universal AC power supply ● (85–265 Vac) Front panel programming ● 1 DC power models (9–30 Vdc) 1 Product Selection 1 LED Count Control, Six-Digit 57700481 Description Catalog Number 1 Relay out, 9–30 Vdc power 57700481 Relay out, 85–265 Vac power 57701481 1 Relay and analog out, 9–30 Vdc power 57700483 1 Relay and analog out, 85–265 Vac power 57701483 Relay and RS-485 out, 9–30 Vdc power 57700485 1 Relay and RS-485 out, 85–265 Vac power 57701485 Relay, analog and RS-485 out, 9–30 Vdc power 57700487 1 Relay, analog and RS-485 out, 85–265 Vac power 57701487 1 Totalizers Eclipse Series Description Catalog Number 1 9–30 Vdc power 57700480 1 Analog out, 9–30 Vdc power 57700482 85–265 Vac power 57701480 1 Analog out, 85–265 Vac power 57701482 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Mechanical 1 Cutout dimensions 3.62 in W x 1.77 in H (92 mm x 45 mm) DIN standard Outline dimensions 4.04 in W x 2.19 in H x 3.87 in D (103 mm x 56 mm x 98 mm) 3.60 in (92 mm) maximum 1 depth in panel Enclosure Plastic with polyester front label 1 Connectors Up to six depluggable terminal blocks Environmental 1 Operating environment Indoor use to 2000 meters 1 Temperature Operating 32° to 122°F (0° to 50°C) 1 Storage –4° to 158°F (–20° to 70°C) Humidity 0 to 85% RH, non-condensing 1 Vibration 2.5 Gs, 30 to 200 Hz Shock 30 Gs, 11 ms half sinewave 1 EMC Immunity to EN 50082-2 (heavy industrial) 1 Emissions to EN 50081-2 (heavy industrial) Front panel NEMA 4X when mounted with gasket provided 1 CE EMC immunity and emissions requirements Met using shielded wiring on the RS-485, analog output and pulse input/ power lines. The shields were connected to earth ground at the Eclipse end of the shields. 1 Pollution degree 2 Overvoltage Category II 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-57 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers General Specifications, continued 1 Description Specification Input Power 1 AC powered models (57701-4XX) Input power 85–295 Vac, 47–63 Hz, 20V A 1 External fuse 0.2A, 250 Vac, time delay (T200 mA, 250V) 1 Isolation dielectric strength 2300 Vac DC powered models (57700-4XX) 1 Input power 9–30 Vdc, 12V A External fuse 2.0A, 50 Vdc, time delay (T2A, 50V) 1 Reverse voltage protection Yes Isolation dielectric strength 2300 Vac to signal outputs and relays, 500 Vac to RS-485 and analog outputs 1 Human Interface 1 Display +6, –5 digits Type 0.56 in (14.2 mm) high, seven segment, red LED 1 Data Retention Memory type EEPROM, no batteries required 1 Duration 100 years Count Signal Input 1 Sensor type Sink or source, DIP switch selectable 1 Input impedance 4.75k ohms to +5 Vdc or 34.9k ohms to ground Thresholds 1 High 3.5–28 Vdc Low 0–1.9 Vdc, for single ended signals 1 Magnetic pickup range 200 mV p-p to 65V rms into 34.9k ohms Slow response 200 Hz max. (DIP switch 2 and/or 5 ON) 1 Fast response Count mode A or B 1 Add/add, add/subtract, add w/Inh 8250/8250 1 Fast response Count mode A and B 1 Add/add, add/subtract, add w/Inh 3000/3000 Quad x1, quad x2 3250 1 Quad x4 2000 Control Inputs 1 Sensor type Sink only 1 Input impedance 4.75k ohms to +5 Vdc Thresholds 1 High 3.5 to 28 Vdc Low 0–1.9 Vdc 1 Response 25 ms maximum (5V signal) Accessory Power Output 1 Voltage 12 Vdc +10%/–13% 1 Current 75 mA max. Protection Short-circuit protected 1 1 1 1 1 V13-T1-58 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 Eclipse Series 1 1 2.19 1.772 ±0.02 (55.6) 1 (45 ±0.6) PGM 1 4.04 1 (102.6) 3.622 ±0 .03 (92.00 ±0.8) Panel Cutout 1 Max. Panel Thickness 0.190 (4.83) 1 1 1 3.63 (92.2) 1 3.31 (84.1) 1 0.27 1 (6.9) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-59 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers President Series (Totalizers) 1 Product Description Features Standards and Certifications ● ● ● 1 Eaton’s President Series Eight-digit, LED display, 15 Vdc at 100 mA output UL listed totalizers are heavy-duty 0.56 in (14 mm) power ● CSA marked electronic totalizers with two ● ● Programmable decimal Rear panel screw terminals 1 ● CE marked available sizes. point and count and rate ● NEMA 4 front panel scaling 1 1 1 Product Selection 1 President Series Totalizers President Series Description Catalog Number 1 115/230 Vac, LED red display 58811400 1 115/230 Vac, LED red display, 1/Tau ratemeter 58815400 115 Vac, seven-digit LED red display, basic pulse count 57810400 1 115/230 Vac, LED red display 58810400 Feet/inches totalizer 57810402 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Power Requirements 1 AC operation 115/230 Vac (+10%, –20%) 47–63 Hz 1 DC operation 11–28 Vdc Power 18 watts 1 1 DC power output 15 Vdc (+1, –2). 150 mA if powered from AC or less than 24 Vdc 1 100 mA if powered from 24 Vdc or greater 1 Environment Operating temperature 32° to 130°F (0° to 55°C) 1 Storage temperature –40° to 160°F (–40° to 70°C) Operating humidity 85% non-condensing relative 1 Physical Memory types PROM, RAM, non-volatile NVRAM 1 Note 1 1 DC power output is only regulated if unit is powered by AC or greater than 18.5 Vdc. 1 1 1 1 1 1 1 V13-T1-60 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers General Specifications, continued 1 Description Specification Counter 1 Count range Eight digits (0 to 99,999,999) with rollover Offset range Eight digits (0 to 99,999,999) (offset is used to reset to a non-zero number) 1 Count modes Count with add and subtract inputs 1 Count with up/down direction input (hardware doubling for above modes is provided) 1 Count with count inhibit input Quadrature 1 Doubled quadrature Count speed (scale factor of 1.0000 assumed) 1 58811400 and 58815400 0 to 7,500 counts per second (CPS) with shaft encoders or solid-state sensors 0 to 3,750 CPS when hardware doubling is implemented or when quadrature 1 shaft encoders are used 0 to 150 CPS when low frequency is selected 1 57810400, 58810400 and 57810-402 0 to 10,000 counts per second (CPS) with shaft encoders or solid-state sensors with internal pull-up resistor 1 0 to 7,500 CPS minimum for sensors with open collector transistor output 0 to 5,000 CPS when hardware doubling is implemented 1 1 Count Input Ratings 1 Input voltage High state (logical “1“, sensor off or contact open) 10.5–24.5 Vdc when control is powered by AC line 1 7.0–24.5 Vdc when control is powered by 11 Vdc 11.0–24.5 Vdc when control is powered by 16 Vdc 1 Low state (logical “0”, sensor on or contact closed) 0–4.5 Vdc when control is powered by AC line 0–3.3 Vdc when control is powered by 11 Vdc 1 0–4.8 Vdc when control is powered by 16 Vdc 1 Input impedance 6800 ohms to 15 Vdc when control is powered by AC line 6800 ohms to 10 Vdc when control is powered by DC supply 1 Input current 20 mA peak, 3 mA steady state Input response 1 High state (logical “1”, sensor off or contact open) High speed (low speed jumpers not connected) 110 μS minimum at 15 Vdc (6,800 ohms to +DC) 1 160 μS minimum at 13.5 Vdc (50,000 ohms to +DC) High state (logical “1“, sensor off or contact open) Low speed (low speed jumpers connected) 1 5.5 ms minimum at 15 Vdc (6,800 ohms to +DC) 1 7.5 ms minimum at 13.5 Vdc (50,000 ohms to +DC) Low state (logical “0”, sensor on or contact closed) High speed (low speed jumpers not connected) 1 20 μS minimum at 0.1 Vdc (0 ohms to DC common) 45 μS minimum at 1.5 Vdc (500 ohms to DC common) 1 Low state (logical “0”, sensor on or contact closed) Low speed (low speed jumpers connected) 1 1.0 ms minimum at 0.1 Vdc (0 ohms to DC common) 2.0 ms minimum at 1.5 Vdc (500 ohms to DC common) 1 Note 1 The count inputs are designed to work with current sinking sensors (open-collector NPN transistor output with or without passive pull-up resistor) 1 or contact closures to DC common. 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-61 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers General Specifications, continued 1 Description Specification Scale Factor 1 Range Five digits (0.0001 to 9.9999) 1 Control Inputs Input voltage 1 High state (logical “1”, contact open) 15 Vdc maximum Low state (logical “0”, contact closed) 1.2 Vdc maximum 1 Input impedance 4.75k ohms to +5 Vdc Threshold 1 High +3.5 to +22 Vdc Low +0.0 to +1.0 Vdc 1 1 Response time Min. high 5.3 ms 1 Min. low 3.9 ms 1 Diagnostic Modes Diagnostic modes ROM checksum 1 RAM bit test NVRAM read/write test 1 NVRAM store test 1 NVRAM checksum Watchdog timer 1 Display and LED indicator test Counter Operating Modes 1 Reset Reset to zero Reset to offset value 1 Maintained Reset 1 Momentary Reset Communications 1 Interface type Dual port 20 mA current loop Speed 110, 300 and 1200 baud, user selectable 1 Data type Standard ASCII code Format Start bit, 7 ASCII data bits, parity bit, one or two stop bits 1 (even parity for serial data output, no parity for serial data input) Information transmitted Count value 1 Offset value 1 Scale factor Information received Print request 1 Offset value Scale factor 1 Note 1 The reset and unlatch signals will both occur in less than 200 microseconds after the input signal is detected. 1 The start of the print will occur within 2 milliseconds after the input is detected if the unit is not counting. 1 1 1 1 1 1 V13-T1-62 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 Standard President Size 0.735 ±0.02 1 5.433 ±0.04 (18.7 ±0.5) (138 ±1.0) 1 2.677 ±0.03 Recommended 2.62 ±0.025 1 (68 ±0.7) Panel Cutout (66.67 ±0.6) 1 0.95 ±0.04 5.53 ±0.015 (140.5 ±0.4) (24.1 ±1.0) 1 5.78 ±0.02 (146.8 ±0.5) 5.91 ±0.03 (150.1 ±0.8) 1 1 Offset Count 1234 56789 101112131415161718 IN1 IN2 USE 3.04 ±0.015 Preset 1 1 EXTERNAL FUSE! 12345 Count Function (77.2 ±0.4) 115/230V~ IN OUT K1 K2 ++ 50/60 Hz Reset Enter 1 67890 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 1 5.80 ±0.015 (147.3 ±0.4) 5.38 ±0.02 (136.7 ±0.5) 6.25 ±0.02 (158 ±0.5) 1 1 Compact President Size 5.43 ±0.04 1 (138 ±1.0) 1 1.74 ±0.01 1.77 ±0.025 Recommended (44.20 ±0.25) (45 ±0.6) Panel Cutout 1 1 5.53 ±0.015 (140.5 ±0.4) 0.17 ±0.01 (4.3 ±0.24) 1 1 12345678 12345 2.16 ±0.015 Reset SWA SWB 1 (54.9 ±0.4) IN OUT IN1 115/230V~ IN2 ++ 50/60 Hz PR 12 34567 8 9 10 11 12 13 14 15 16 17 18 1 5.80 ±0.015 (147.3 ±0.4) 5.38 ±0.015 (136.7 ±0.4) 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-63 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers President Series (Count Control) 1 Product Description Features Standards and Certifications ● ● ● 1 Eaton’s President Series Five- or six-digit, LED 20 mA current loop UL listed features an easy-to-read LED display, 0.56 in (14 mm) communications ● CSA marked and a simple preset input by ● ● 1, 2 or 3 presets 2 Form C relays 1 ● CE marked means of the large keypad. ● ● 15 Vdc at 100 mA output Tactile keypad NEMA 4 power front panel 1 ● Rear panel screw terminals 1 1 Product Selection 1 President Series Count Control 58831400 1 Features Batch Main Description Totalizer Counter Rate Scaler Crop-Cut Counter Presets Digits Catalog Number 1 120 Vac, no communications — — ✓ —— 1 1 5 57820400 1 Single preset — — — — — 1 1 5 58821400 Single preset with rate — — ✓✓ —1 1 5 58825400 1 Dual preset — — — ✓ —1 2 5 58831400 Dual preset with batch — ✓ — ✓✓ 12 6 58841400 1 11 Dual preset with totalizer or batch counter — ✓✓ 12 6 58851400 1 Three presets with floating pre-warn — — — ✓ —1 3 6 58861400 22 Main counter, batch and totalizer presets ✓✓ — 3 1 ea. 6 58827400 1 33 Two independent count registers ✓✓ — 3 1 ea. 6 58827410 High-speed count control—30 kHz max. — ✓✓ ✓ —1 2 6 58867400 1 President position controller For more details, see Page V13-T1-124 58868400 1 Notes 1 These models have, in addition to the main count register, a register that may be configured to be used as either a totalizer or single preset batch counter. These two functions are mutually exclusive. 1 2 The model 58827-400 has both a totalizer and a batch counter, each with a single preset. In addition, the batch counter may be configured as an additional totalizer with control instead of batch counter. 3 1 The model 58827-410 has two completely independent count input channels feeding two independent, single preset count registers. In addition, a third single preset register may be used as either a totalizer or a batch counter for one or both of the two main counters. 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-64 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Technical Data and Specifications 1 President Series—Count Control 1 Model Description 57820400 57820401 58821400 58825400 58831400 1 AC power requirements 120V ±10% 240V ±10% 120V/240V +10%/-20%, 47–63 Hz DC power requirements 11–30 Vdc 11–30 Vdc 11–28 Vdc 11–28 Vdc 11–28 Vdc 1 Power consumption 8 watts max. 8 watts max. 18 watts max. 18 watts max. 18 watts max. 1 DC power output 15 Vdc +1/-2 at 85 mA max. 15 Vdc +1/-2; 150 mA if powered from AC or less than 24 Vdc, 1 100 mA if powered from 24 Vdc or greater Operating temperature 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 1 Operating humidity 85% relative, non-condensing 85% relative, non-condensing 85% relative, non-condensing 85% relative, non-condensing 85% relative, non-condensing Storage temperature –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) 1 Front panel rating NEMA 4 rating when mounted with gasket provided Main counter scaler range N/A N/A 5 Digits (0.0001 to 9.9999) 5 Digits (0.0001 to 9.9999) 5 Digits (0.0001 to 9.9999) 1 Count input frequency 10 kHz 10 kHz See table on Page V13-T1-66 See table on Page V13-T1-67 See table on Page V13-T1-66 (5 kHz in quadrature) (5 kHz in quadrature) 1 Count input impedance 6.8k ohms to 15 Vdc when control is powered by AC line; 6.8k ohms to 10 Vdc when control is powered by DC line 1 Control input threshold High 10.5 to 24.5 Vdc; Low 0.0 to 4.5 Vdc when powered by AC 1 Control input impedance 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc Control input response time Min. high 5.3 ms; min. low 3.9 ms 1 Relay contact output ratings SPDT Form C; 10 amps resistive at 24 Vdc or 230 Vac; 1/3 hp at 115 Vac or 230 Vac; 150 Vdc max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating 1 Transistor output ratings Open collector NPN transistor with Zener diode transient surge protection; 30 Vdc max. load; 300 mA max. per transistor; 480 mA total for all transistors. Use 5 mA per relay coil when calculating total transistor current 1 Communications N/A N/A Dual port 20 mA current loop, standard ASCII code 1 President Series—Count Control, continued Model 1 Description 58841400 58851400 58827400 58827410 58867400 AC power requirements 120V/240V +10%/-20%, 47–63 Hz 1 DC power requirements 11–28 Vdc 11–28 Vdc 11–28 Vdc 11–28 Vdc 11–28 Vdc Power consumption 18 watts max. 18 watts max. 18 watts max. 18 watts max. 18 watts max. 1 1 DC power output 15 Vdc +1/-2; 150 mA if powered from AC or less than 24 Vdc, 100 mA if powered from 24 Vdc or greater 1 Operating temperature 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) 32° to 130°F (0° to 55°C) Operating humidity 85% relative, non-condensing 1 Storage temperature –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) –10° to 160°F (–40° to 71°C) Front panel rating NEMA 4 rating when mounted with gasket provided 1 Main counter scaler range 5 digits 5 digits 5 digits 5 digits 6 digits (0.0001 to 9.9999) (0.0001 to 9.9999) (0.0001 to 9.9999) (0.0001 to 9.9999) (0.00001 to 9.99999) 1 Count input frequency See table on Page V13-T1-66 See table on Page V13-T1-66 See table on Page V13-T1-66 See table on Page V13-T1-67 See table on Page V13-T1-67 Count input impedance 6.8k ohms to 15 Vdc when control is powered by AC line; 1 6.8k ohms to 10 Vdc when control is powered by DC line Control input threshold High 10.5 to 24.5 Vdc; 1 Low 0.0 to 4.5 Vdc when powered by AC Control input impedance 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 4.5k ohms to +5 Vdc 1 Control input response time Min. high 5.3 ms; min. low 3.9 ms Relay contact output ratings SPDT Form C; 10 amps resistive at 24 Vdc or 230 Vac; 1/3 hp at 115 Vac or 230 Vac; 1 150 Vdc max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating Transistor output ratings Open collector NPN transistor with Zener diode transient surge protection; 1 30 Vdc max. load; 300 mA max. per transistor; 480 mA total for all transistors. Use 5 mA per relay coil when calculating total transistor current 1 Communications Dual port 20 mA current loop, standard ASCII code Note 1 1 DC power output is only regulated if unit is powered by AC or greater than 18.5 Vdc. 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-65 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers 58821400 Count Frequency 1 Count Speed (Pulses per Second) Scale Factor Nominal Count Quadrature and/or Doubled Count 1 <1.0000 6,250 3,125 1.0000 7,500 3,750 1 1.9999 5,000 2,500 1 2.0000 6,250 3,125 9.0000 2,500 1,250 1 9.9999 2,000 1,000 1 58831400, 58841400, 58861400 Count Frequency 1 Count Speed (Pulses per Second) Scale Factor Nominal Count Quadrature and/or Doubled Count 1 <1.0000 5,000 2,500 1 1.0000 7,500 3,750 1.9999 4,000 2,000 1 2.0000 6,000 3,000 9.0000 2,000 1,000 1 9.9999 1,500 750 1 58851400 Count Frequency 1 Count Speed (Pulses per Second) Function 61 value = “0” Function 61 value = “1” 1 Quadrature and/or Quadrature and/or Scale Factor Nominal Count Doubled Count Nominal Count Doubled Count 1 <1.0000 5,000 2,500 3,500 1,750 1.0000 7,500 3,750 4,500 2,250 1 1.9999 4,000 2,000 2,400 1,200 1 2.0000 6,000 3,000 3,600 1,800 9.0000 2,000 1,000 1,100 550 1 9.9999 1,500 750 1,000 500 1 58827400 Count Frequency 1 Count Speed (Pulses per Second) Scale Factor Count Up Count Down Quadrature 1 0.999 4,000 2,250 2,000 1 1.000 5,000 3,500 3,500 1.999 3,500 2,000 1,250 1 2.000 4,000 3,000 2,750 9.000 1,500 1,500 1,500 1 9.999 1,250 1,000 1,000 1 1 1 1 1 1 V13-T1-66 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers 1 58867400 Count Frequency 1 Count Speed (Pulses per Second) Count Mode X1 X2 X3 1 High speed 30,000 15,000 7,500 Low speed 200 200 200 1 1 58827410 Count Frequency Count Speed (Pulses per Second) 1 2 Typical Combinations of Features C1 = ON C1 = ON C1 = ON C1 = ON C1 = ON 1 C2 = OFF C2 = ON C2 = ON C2 = ON C2 = ON C3 = OFF C3 = OFF C3 = ON C3 = OFF C3 = ON 1 Sample Scale Factor RM = OFF RM = OFF RM = OFF RM = ON RM = ON 0.0001–0.9999 6,000 3,000 2,300 2,600 2,000 1 1.0000 9,000 4,500 3,500 4,000 3,000 5.0000 4,500 2,250 1,000 2,000 750 1 9.9999 1,500 1,000 500 750 550 1 58825400 Count Frequency 1 Count Speed (Pulses per Second) Scale Factor Nominal Count Quadrature and/or Doubled Count 1 <1.0000 4,200 2,100 1 1.0000 7,500 3,750 1.9999 3,450 1,720 1 2.0000 6,250 3,120 9.0000 2,500 1,250 1 9.9999 1,800 900 1 Notes 1 The maximum count input frequency depends only on the selected count mode (doubled or quadrature x4). 1 The maximum input frequencies shown are with square wave (50% duty cycle) input. 2 C1: Counter #1; C2: Counter #2; C3: Counter #3; RM: Ratemeter. 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-67 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 President Series Count Control 5.433 ±0.04 1 (138 ±1.0) 0.735 ±0.02 1 (18.7 ±0.5) 1 2.62 ±0.025 2.677 ±0.03 (66.67 ±0.6) Recommended (68 ±0.7) Panel Cutout 1 0.95 ±0.04 (24.1 ±1.0) 1 5.53 ±0.015 (140.5 ±0.4) 1 5.78 ±0.02 (146.8 ±0.5) 5.91 ±0.03 (150.1 ±0.8) 1 5.80 ±0.015 1 (147.3 ±0.4) 1 Preset 1234 5 6 7 8 9 10 11 1213 14 15161718 1 IN1 IN2 Count USE Preset 1 Preset 2 3.04 ±0.015 EXTERNAL K1 K2 1 (77.2 ±0.4) Count Function FUSE! 12345 IN OUT 115/230V~ K1 K2 ++ 50/60 Hz 1 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Reset Enter 67890 1 1 5.38 ±0.02 (136.7 ±0.5) 6.25 ±0.02 (158 ±0.5) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-68 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Ambassador Series (Totalizers) 1 Product Description Features Standards and Certifications ● ● Four user-configurable ● Eaton’s Ambassador Series is AC/DC powered, two-line UL listed 1 control inputs our most noise-immune LCD display ● CE marked ● totalizer available. Various ● Two solid-state outputs Eight-digit totalizer 1 counting modes can be set ● ● RS-485 serial 1/Tau ratemeter by the user. communications ● 1 Totalizer and ratemeter scaling 1 Product Selection 1 Ambassador Series Totalizers Ambassador Series Description Catalog Number 1 10–15 Vdc LCD 57600400 115 Vac LCD 57601400 1 230 Vac LCD 57602400 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Power Input AC operation 115 Vac (±15%) std., 50 to 60 Hz, 7W 1 230 Vac (±15%) opt., 50 to 60 Hz, 7W 1 DC operation 10–15 Vdc opt., 300 mA maximum DC power output 12 Vdc (±25%), 100 mA maximum (includes all line and load variations) 1 Environmental Operating temperature 32° to 131°F (0° to 55°C) 1 Storage temperature –4° to 158°F (–20° to 70°C) Operating humidity 85% relative, non-condensing 1 Rating NEMA 4 when mounted with gasket provided 1 Totalizer Type Bi-directional 1 Digits Eight Scaler range 0.00001 to 9.99999 1 Decimal point Five positions, programmable 1 Totalizer Count Speeds 1 Maximum speed—solid-state (high speed) 1 Mode Input A/Input B Add/sub 20 kHz 1 Add/add 20 kHz Count/direction 15 kHz 1 Count x 2/direction 7.5 kHz Quadrature 6.5 kHz 1 Quadrature x 2 6.5 kHz 1 Maximum speed—contact (low speed) Mode Input A/Input B 1 Add/sub 40 kHz Add/add 40 kHz 1 Count/direction 0 kHz 1 Note 1 The maximum count speed depends on the selected count mode. All maximum speeds are shown with square waves (50% duty cycle) input. 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-69 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers General Specifications, continued 1 Description Specification Count Inputs 1 Sink Impedance 4.6k ohms to +5 Vdc 1 Voltage 1 High 3.5 to 34.0 Vdc Low 0.0 to 1.9 Vdc 1 Source (high) Impedance 2.3k ohms to common 1 Voltage High 3.5 to 17.0 Vdc (100% duty cycle) 1 Low 0.0 to 1.9 Vdc Source (low) 1 Impedance 2.3k ohms to common DC voltage 1 High 0.6 to 17.0 Vdc Low –17.0 to –0.6 Vdc 1 AC voltage 17 Vac (48V peak-peak) maximum 1 Control Inputs Impedance 4.7k ohms to +5 Vdc 1 Voltage High +3.7 to +24 Vdc 1 Low 0.0 to 0.9 Vdc Response Minimum low 15 ms, minimum high 15 ms 1 Transistor Outputs (2) 1 Type NPN open collector with transient protection Maximum voltage (OFF state) 30 Vdc 1 Maximum current (ON state) 200 mA at 1.3 Vdc Communication 1 Type RS-485 Format 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit 1 Protocol Opto-22 compatible 1 Speed 300, 1200, 2400, 4800, 9600 and 19200 baud Parity Odd, even, none (space transmitted, ignore received) 1 Count Accuracy Operating within specifications 100% when operated within the specified count speeds and count signal high and low times 1 Rate Indicator 1 Type 1/Tau Digits Six 1 Scaler range 0.00001 to 99999 Decimal point Five positions, programmable 1 Accuracy ±0.015% of reading Update time 1 second, fixed 1 Zero time 10 seconds, fixed 1 Connections Type Dual depluggable screw terminal strips 1 2 Conductor size 14–22 AWG (2.1–0.38 mm ), 600V, solid, stranded or fused (preferred) 1 1 1 V13-T1-70 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 Ambassador Series Totalizer 1 1 C 123456 P1 10000 1 2.946 ±0.015 (74.83 ±0.38) RST RUN PRNT CLR PGM • 1 EXIT ENT SEL 1 2.946 ±0.015 5.60 ±0.03 1 (74.83 ±0.38) (142.24 ±0.76) 1 Gasket 1 1 1 2 2 3 3 4 4 Panel Cutout 1 5 5 2.677 ±0.028 Max. Panel 6 6 (68.00 ±0.70) Thickness 7 7 1 8 0.50 (12.7) 8 9 9 10 10 1 11 12 1 2.677 ±0.028 (68.00 ±0.70) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-71 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Ambassador Series (Count Control) 1 Product Description Features Standards and Certifications ● ● ● 1 Eaton’s Ambassador Series AC/DC powered, two-line Up to two output relays UL listed provides up to four presets in LCD display ● ● Two solid-state outputs CE marked one of the most noise- ● Eight-digit totalizer 1 ● RS-485 serial immune packages available. ● 1/Tau ratemeter communications 1 ● ● Totalizer and ratemeter Feet/inches control scaling available ● 1 Four user-configurable control inputs 1 Product Selection 1 Ambassador Series Count Control 57601401 1 Description Catalog Number 1 Single preset with rate, 115 Vac 57601401 Single preset with rate, batch and totalizer, 115 Vac 57601402 1 Dual preset with rate, 115 Vac 57601403 Dual preset with rate, batch and totalizer, 115 Vac 57601404 1 Four preset with rate, batch and totalizer, 10–15 Vdc 57600405 Four preset with rate, batch and totalizer, 115 Vac 57601405 1 Four preset with rate, batch and totalizer, 230 Vac 57602405 1 Feet/inches control, 115 Vac 57601415 Feet/inches control, 230 Vac 57602415 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Power Input AC operation 115 Vac (±15%) std., 50 to 60 Hz, 7W 1 230 Vac (±15%) opt., 50 to 60 Hz, 7W DC operation 10–15 Vdc opt., 300 mA maximum 1 Power Output DC operation 12 Vdc (±25%), 100 mA maximum (includes all line and load variations) 1 Environmental Operating temperature 32° to 131°F (0° to 55°C) 1 Storage temperature –4° to 158°F (–20° to 70°C) 1 Operating humidity 85% relative, non-condensing NEMA 4 rating When mounted with gasket provided 1 Main Counter Type Bi-directional 1 Digits Six Presets Varies by model 1 Reset modes Auto or manual reset to zero or preset Scaler range 0.00001 to 9.99999 1 Decimal point Five positions (six on four-preset models) Output latency See table on Page V13-T1-74 1 Batch Counter Type Increment with main counter recycle or final preset signal 1 Digits Six Presets One 1 Output latency <1 ms 1 V13-T1-72 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers General Specifications, continued 1 Description Specification Totalizer 1 Type Bi-directional, same or opposite of main counter Digits Eight 1 Scaler Shared with main counter Decimal point Tracks main counter 1 Count Input Speeds See tables on Page V13-T1-74 1 Count Inputs Sink 1 Impedance 4.6k ohms to +5 Vdc Voltage 1 High 3.5 to 34.0 Vdc Low 0.0 to 1.9 Vdc 1 Source (high) Impedance 2.3k ohms to common 1 Voltage High 3.5 to 17.0 Vdc (100% duty cycle) 1 Low 0.0 to 1.9 Vdc Source (low) 1 Impedance 2.3k ohms to common DC voltage 1 High 0.6 to 17.0 Vdc Low –17.0 to –0.6 Vdc 1 AC voltage 17 Vac (48V peak-peak) maximum Control Inputs 1 Impedance 4.7k ohms to +5 Vdc 1 Voltage High +3.7 to +24 Vdc Low 0.0 to 0.9 Vdc 1 Response Minimum low 15 ms, minimum high 15 ms 1 Relay Outputs Type SPDT contacts 1 UL ratings 250 Vac, 360V A pilot duty Transistor Outputs (2) 1 Type NPN open collector with transient protection Maximum voltage (OFF state) 30 Vdc 1 Maximum current (ON state) 200 mA at 1.3 Vdc Communication 1 Type RS-485 Format 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit 1 Protocol Opto-22 compatible Speed 300, 1200, 2400, 4800, 9600 and 19200 baud 1 Parity Odd, even, none (space transmitted, ignore received) Rate Indicator (Not available on models 57601-415 and 57601-485) 1 1/Tau Type 1 Digits Six Presets Two 1 Scaler range 0.00001 to 99999 Decimal point Five positions, programmable 1 Accuracy ±0.015% of reading Update time See table on Page V13-T1-74 1 Zero time See table on Page V13-T1-74 Connections 1 Type Dual depluggable screw terminal strips 2 Conductor size 14–22 AWG (2.1–0.38 mm ), 600V, solid, stranded, or fused (preferred) 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-73 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Output Latency for Ambassador Control 1 Style Number Output Latency 5760X401 0.7 to 2 ms 1 5760X402 0.7 to 2 ms 1 5760X403 0.7 to 2.7 ms 5760X404 0.7 to 2.7 ms 1 5760X405 <1 ms 5760X415 <1 ms 1 1 Rate Indicator Specs for Ambassador Control Style Number Update Time Zero Time 1 5760X401 1 second, fixed 10 seconds, fixed 1 5760X402 1 second, fixed 10 seconds, fixed 5760X403 1 second, fixed 10 seconds, fixed 1 5760X40 1 second, fixed 10 seconds, fixed 5760X405 0.1 to 99.9 seconds, programmable 0.1 to 99.9 seconds, programmable 1 5760X415 0.1 to 999.9 seconds, programmable 0.1 to 999.9 seconds, programmable 1 1 Ambassador Count Input Speeds—5760X405, 5760X415 1 Solid-State A or B A and B 1 A – B 8250/8250 3000/3000 A + B 8250/8250 4000/4000 1 –A + B 8000/8000 3000/3000 A, B Dir 8000/40 — 1 2A, B Dir 4500/40 — A, B Rst 8250 — 1 Quad x 1 — 3250 1 Quad x 2 — 3250 Quad x 4 — 2000 1 Tot A/Cnt B 14000/9000 6500/6500 Tot + Cnt B 16000/8500 6500/6500 1 1 Ambassador Count Input Speeds—5760X401, 5760X402, 5760X403, 5760X404 2 Maximum Speed 1 Mode Solid-State Contact Input A/B (High Speed) (Low Speed) 1 Add/sub 20 kHz 40 kHz Add/add 20 kHz 40 kHz 1 Count/direction 15 kHz 40 kHz 1 Count x 2/direction 7.5 kHz — Quadrature 6.5 kHz — 1 Quadrature x 2 6.5 kHz — 1 Notes 1 Contact inputs = 40 Hz; B direction inputs = 40 Hz and B reset input = 10 μS min. low. Input A not active on ft/in control. 2 The maximum count speed depends on the selected count mode. All maximum speeds are shown with square waves (50% duty cycle) input. 1 1 1 1 V13-T1-74 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Dimensions 1 Approximate Dimensions in Inches (mm) 1 Ambassador Series 1 1 C 123456 P1 10000 1 2.946 ±0.015 (74.83 ±0.38) RST RUN PRNT CLR PGM 1 • EXIT ENT SEL 1 1 2.946 ±0.015 5.60 ±0.03 (74.83 ±0.38) (142.24 ±0.76) 1 Gasket 1 1 1 2 2 3 3 1 4 4 Panel Cutout 5 5 2.677 ±0.028 Max. Panel 6 6 (68.00 ±0.70) Thickness 1 7 7 8 0.50 (12.7) 8 9 9 10 10 1 11 12 1 2.677 ±0.028 (68.00 ±0.70) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-75 Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers PD-Q and PD-ER Series 1 Product Description Features Standards and Certifications ● ● 1 The PD-Q Series is a five- The output signal from this Easy setpoint adjustment UL recognized as indicated digit, true subtracting electric switch can be used to halt or ● Available in base mount or predetermined counter that change the flow of items panel mount configurations 1 features pushbutton operation being counted, and/or of both predetermined count operate other electrical 1 settings and reset. The apparatus. The counter predetermined count is set returns to the predetermined 1 by holding the RESET button number when the RESET in and then depressing the button is depressed and it is easy to operate pushbutton immediately ready to control 1 selectors under each digit. the next lot or batch. The unit subtracts, one count 1 The PD-ER Series is identical for each contact closure or to the PD-Q Series, except impulse and actuates a 1 that it has electric reset (ER) 4 ampere, 250 Vac switch for remote operation, allowing when zero is reached. either local or remote use. 1 1 Product Selection 1 When Ordering Specify When ordering PD-Q and 1 PD-ER Series Predetermined Counters, specify catalog numbers according to the 1 features selected. 1 PD-Q and PD-ER Series Predetermined Counters 5-Y-41433-*-PD-Q 1 Voltage Mounting Wire Leads Catalog Number Order Number 12 Vdc Panel Rear 5-Y-41433-401-PD-Q 41433401 1 1 24 Vdc Panel Rear 5-Y-41433-402-PD-Q 41433402 1 120 Vac Panel Rear 5-Y-41433-406-PD-Q 41433406 1 240 Vac Panel Rear 5-Y-41433-407-PD-Q 41433407 24 Vac Panel Rear 5-Y-41433-408-PD-Q 41433408 1 1 24 Vdc Base Rear 5-Y-41469-402-PD-Q 41469402 1 1 120 Vac Base Rear 5-Y-41469-406-PD-Q 41469406 240 Vac Base Rear 5-Y-41469-407-PD-Q 41469407 1 1 24 Vdc Base Side 5-Y-41470-402-PD-Q 41470402 1 120 Vac Base Side 5-Y-41470-406-PD-Q 41470406 1 240 Vac Base Side 5-Y-41470-407-PD-Q 41470407 1 1 24 Vdc Panel Rear 5-Y-41625-402-PD-ER 41625402 1 120 Vac Panel Rear 5-Y-41625-406-PD-ER 41625406 1 240 Vac Panel Rear 5-Y-41625-407-PD-ER 41625407 Note 1 1 UL recognized. 1 1 1 1 1 1 V13-T1-76 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.2 Count Controls/Preset Counters/Totalizers Technical Data and Specifications 1 General Specifications 1 Description Specification Number of digits Five 1 Speed 1000 cpm 1 Window Acrylic Shaft Stainless steel 1 Frame Zinc alloy die cast Digit size 3/16 in high by 7/64 in wide (4.8 x 2.8 mm) 1 Weight Series PD-Q 0.53 lb (0.24 kg) 1 Series PD-ER 1.06 lb (0.48 kg) Finish Dull Instrument black with red RESET button 1 Power consumption 1 Series PD-Q 9 watts Series PD-ER Count coil 9 watts, reset coil 20 watts 1 Switch rating SPDT, 4 amperes at 250 Vac 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 PD-Q and PD-ER Series 2.72 1 (69.0) 2.69 3.38 (68.2) (85.7) 1.59 1 Hole Dia. (40.5) 3.00 1.56 0.13 (3.2) (72.6) (39.7) 1 1.69 1.31 (42.8) 1.56 1.18 3.06 (33.3) Dia. 0.14 (39.7) (30.1) (77.8) 1 (3.6) 3.00 2.97 1.69 (75.4) (76.2) 4.38 (42.8) 1 (111.1) 3.38 4.00 (85.7) 2.69 1 (101.6) (68.2) 1 1.63 2.00 (41.3) (50.8) 1 1.69 3.22 1 (42.8) (81.8) 2.69 1 (68.2) 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-77 Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters Contents Tachometers/Ratemeters 1 Description Page Count Controls/Preset Counters 1 Product Selection Guide . . . . . . . . . . . . . . . . . . V13-T1-79 1 Courier Series . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-80 Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-82 1 Ambassador Series . . . . . . . . . . . . . . . . . . . . . V13-T1-85 Learn 1 Online 1 1 1 1 1 1 Product Overview Ratemeters are used in a Application Example 1 variety of applications where 0 to 10 Vdc it is necessary to monitor the Feedback to Motor 1 speed of a process. Drive Conveyors, baking ovens, Proximity 1 material flow and motor Sensor speed are typical uses for ratemeters. Models with 1 alarm outputs can be used to detect high or low rates. Rate 1 indicators are often included as a standard feature on High Alarm 1 totalizers and count controls. Output Motor 1 Typical Application Low Alarm Output One of the most common 1 ratemeter applications is a tachometer. A tachometer 1 displays motor or shaft RPM. The inductive proximity sensor detects the key on the 1 shaft and the meter calculates the rate at which 1 the shaft is turning based on a user-defined scaling factor. 1 Signals from encoders, mag pickups, Hall effect sensors, 1 etc. may also be used as inputs. 1 1 1 1 1 1 V13-T1-78 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters Product Selection Guide 1 Tachometers/Ratemeters 1 Panel Cutout Characteristics in Inches (mm) Page 1 E5-_24-E Compact device with bright, LED display 0.870 x 1.772 V13-T1-44 (22 x 45) Multiple functions available: count, time, rate, multifunction, 1 double-function 24 Vdc Power 1 E5-496-E Economical, multifunction display 1.772 x 3.780 V13-T1-49 1 (45 x 96) Large, LED characters AC or DC power options 1 1 President Bright LED display with 14 mm characters 2.667 x 5.433 V13-T1-60 (68 x 138) 1 Simple configuration with 14-button tactile keypad Many different versions fit almost any application 1 1 E5-148-C Low cost, simple count control 1.772 x 1.772 V13-T1-53 (45 x 45) Various power options: battery, AC, DC 1 Easy-to-change preset values Two-line display: input and preset values 1 1 Courier Replaceable lithium battery 1.299 x 2.677 V13-T1-80 (33 x 68) Eight-digit, high-visibility LCD display 1 Optional backlighting Various input options available 1 Eclipse Six-digit, super bright LED display 1.772 x 3.780 V13-T1-82 1 (45 x 96) Multiple models available: totalizers, ratemeters, count controls, digital panel meters and flow controls 1 1 Ambassador Six-digit, high-visibility, two-line LCD display 2.667 x 2.667 V13-T1-85 (68 x 68) User-configurable control inputs 1 Highly flexible control/display 1 1 Fusion Integrated controller combines operator interface, ladder logic and 2.667 x 5.433 V13-T1-119 high-speed counting (68 x 138) 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-79 Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters Courier Series 1 Product Description Features Standards and Certifications ● ● 1 Eaton’s Courier Series is 1/Tau ratemeter CE marked powered by a replaceable ● Scaling capabilities lithium battery. 1 ● Remote reset terminal ● 0.43 in (10.9 mm) display 1 ● Front panel reset ● NEMA 4X 1 1 Product Selection 1 1 LCD 1/Tau Ratemeter Courier Series Description Catalog Number 1 Battery 53300404 Extended temperature range, battery 53301404 1 Backlight, battery 53302404 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Power Internal battery 3V, Lithium 1 Life expectancy 5 years + 1 Replacement part 35367-202 Backlight 1 2 Backlight 10–30 Vdc at 30 mA max. Reverse polarity protected 1 Physical Operating temperature 1 Model 53300-404 32° to 131°F (0° to 55°C) 1 Model 53301-404 –4° to 158°F (–20° to 70°C) Model 53302-404 32° to 131°F (0° to 55°C) 1 Storage temperature –4° to 158°F (–20° to 70°C) Operating humidity 60% RH (non-condensing) 1 Weight 2.2 oz. (62g) net Display size 0.43 in (10.9 mm) high 1 Front panel rating NEMA 4X when mounted with gasket provided 1 Case material Cycolac X-17 Rate Indicator 1 Type 1/Tau Digits 4/5 (four calculated, five displayed with fixed 0 in LSD) 1 Scaler range 0.001 to 9999 Decimal point Five positions, programmable 1 Accuracy ±0.2% 1 Update time 0.7 seconds Zero time 10 seconds 1 Notes 1 For units with rate and total, see Totalizers. 1 2 Derate operating temperature 1°C/Volt above 17 Vdc. 1 V13-T1-80 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters General Specifications, continued 1 Description Specification DC Common (Terminal 1) Rate Inputs 1 Input B (terminal 2) low speed input designed for contact closures to DC common 1 Speed 0 to 20 Hz Min. low time 10 ms 1 Min. high time 40 ms Input impedance 101k ohm 1 Voltage thresholds 1 Low 0–0.4 Vdc High 2.0–28 Vdc 1 Max. high 28 Vdc Input A (terminal 3) high speed input requiring a voltage 1 source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors 1 1 Speed 0 to 10 Hz 1 Min. low time 80 ms 1 1 Min. high time 20 ms Input impedance 2k ohms above 5 Vdc 1 Voltage thresholds Low 0–1.2 Vdc 1 High 2.0–28 Vdc Max. high 28 Vdc 1 Programmable Enable Input (Terminal 5) 1 Operation Level sensitive (maintained) Count Accuracy 1 Operated within specifications 100% 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 Courier Series Ratemeter 1 1.25 (31.8) 1 1 1 1 2.95 (74.9) 2.67 (67.8) 1 1 1.57 Recommended 1.30 (39.9) Panel Cutout (33.0) 1 T/R RST 1 Note 1 1 Times are with a 0–5.0V swing. 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-81 Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters Eclipse Series 1 Product Description Features Standards and Certifications ● ● 1 Eaton’s Eclipse Series offers 1/8 DIN cutout UL and cUL listed a high visibility LED and a ● ● NEMA 4X front panel CE marked variety of optional outputs. 1 ● Universal AC power supply (85–265 Vac) 1 ● DC power modules (9–30 Vdc) ● 1 Removable screw terminals ● Short depth: 3.6 in (91 mm) 1 ● Front panel programming 1 Product Selection 1 Eclipse Series Five-Digit LED Ratemeter 57700470 Description Catalog Number 1 9–30 Vdc 57700470 1 9–30 Vdc, alarms 57700471 9–30 Vdc, analog out 57700472 1 9–30 Vdc, alarms, analog out 57700473 9–30 Vdc, RS-485 57700474 1 9–30 Vdc, alarms, RS-485 57700475 9–30 Vdc, alarms, analog out, RS-485 57700477 1 85–265 Vac 57701470 85–265 Vac, alarms 57701471 1 85–265 Vac, analog out 57701472 1 85–265 Vac, alarms, analog out 57701473 85–265 Vac, RS-485 57701474 1 85–265 Vac, alarms, RS-485 57701475 85–265 Vac, analog out, RS-485 57701476 1 85–265 Vac, alarms, analog out, RS-485 57701477 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Input Power 1 AC powered models (57701-4XX) Input power 85–265 Vac, 47–63 Hz, 20V A 1 External fuse 0.2A, 250 Vac, time delay (T200 mA, 250V) Isolation dielectric strength 2300 Vac 1 DC powered models (57700-4XX) Input power 1 9–30 Vdc, 12 VA External fuse 2.0A, 50 Vdc, time delay, (T2A, 50V) 1 Reverse voltage protection Yes Isolation dielectric strength 2300 Vac to signal inputs and relays, 500 Vac to RS-485 and analog outputs 1 Human Interface Display Five digits 1 Type 0.56 in high, seven segment, red LED Indicator One red LED program/calibration indicator 1 Update time 0.1 to 99.9 seconds minimum 1 1 V13-T1-82 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters General Specifications, continued 1 Description Specification Data Retention 1 Memory type EEPROM, no batteries required Duration 100 years 1 Signal Input Rate/process time Signal in 1 Sensor type Sink or source, DIP switch selectable Input impedance 4.75k ohms to +5 Vdc or 34.9k ohms to ground 1 Thresholds High 3.5 to 28 Vdc 1 Low 0 to 1.9 Vdc, for single ended signals 1 Magnetic pickup range 200 mV p-p to 65V rms into 34.9k ohms Frequency response 200 Hz max. or 10 kHz max. (5V signals), DIP switch selectable 1 Program Enable Input Sensor type Sink only 1 Input impedance 4.75k ohms to +5 Vdc Thresholds 1 High 3.5 to 28 Vdc Low 0 to 1.9 Vdc 1 Response 25 ms max. (5V signal) Accessory Power Output 1 Voltage 12 Vdc ±12% Current 75 mA max. 1 Protection Short-circuit protected 1 Optional Outputs Relay board 1 Number of relays Two Contact type 1 set Form C per relay 1 Contact rating 5A, 250 Vac or 30 Vdc Isolation dielectric strength 2300 Vac 1 Analog retransmission Output signals 4–20 mA (<750 ohms) and 0–10V (>2500 ohms) 1 Accuracy 0.13% full scale and 100 PPM/°C (and 0.07% full scale change over 4–20 mA load ranges) Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to RS-485 and DC power 1 inputs RS-485 serial communications 1 Baud rate 1200, 2400, 4800, 9600, or 19,200, programmable Parity Even, odd or no parity 1 Address range 00 to 99 decimal ® Protocol Opto 22 compatible 1 Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and DC power inputs 1 Environmental Operating environment Indoor use to 2000 meters 1 Temperature Operating 32° to 122°F (0° to 50°C) 1 Storage –4° to 158°F (–20° to 70°C) Humidity 0 to 85% RH, non-condensing 1 Vibration 2.5 Gs, 30 to 200 Hz Shock 30 Gs, 11 ms half sinewave 1 EMC Immunity to EN 50082-2 (heavy industrial) Emissions to EN 50081-2 (heavy industrial) 1 Front panel NEMA 4X when mounted with gasket provided 1 CE EMC immunity and emissions requirements Met using shielded wiring on the RS-485, analog output and pulse input/ power lines. The shields were connected to earth ground at the Eclipse end of the shields. Pollution degree 2 Overvoltage Category II 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-83 Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters Dimensions 1 Approximate Dimensions in Inches (mm) 1 Eclipse Series Ratemeter 1 1 2.19 1.772 ±0.02 (55.6) (45 ±0.6) 1 PGM 1 4.04 1 (102.6) 3.622 ±0 .031 (92.00 ±0.8) Panel Cutout 1 Max. Panel Thickness 1 0.190 (4.83) 1 1 3.63 (92.2) 1 3.31 (84.1) 1 0.27 (6.9) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-84 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters Ambassador Series 1 Product Description Features Standards and Certifications ● ● ● Eaton’s most noise-immune AC/DC powered, two-line Programmable average and UL and cUL listed 1 ratemeter with an easy-to- LCD display zero times ● CE marked read two-line LCD. ● ● Two-line, five-digit, high Programmable decimal 1 visibility, 0.3 in (7.5 mm) point characters, backlit display ● 12 Vdc, 100 mA max. 1 ● One or two rate inputs output power ● ● Two rate alarms Removable screw 1 terminals ● Dual rate unit ratio ● calculations—A/B, A-B or RS-485 communications 1 draw ● NEMA 4 front panel 1 Product Selection 1 Ambassador Series Ratemeter 1 57150400 Description Catalog Number 1 Single Input LCD rate indicator, 2 rate alarms, 10–15 Vdc 57150400 1 LCD rate indicator, 2 rate alarms, 115 Vac 57151400 LCD rate indicator, 2 rate alarms, 230 Vac 57152400 1 1 Dual Input Rate/ratio/draw with alarms and analog out, 10–15 Vdc 57150405 1 Rate/ratio/draw with alarms and analog out, 115 Vac 57151405 Rate/ratio/draw with alarms and analog out, 230 Vac 57152405 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Power Input Model 57150-40X 10 to 15 Vdc, 300 mA maximum 1 Model 57151-40X 115 Vac (±15%) 50–60 Hz, 7W 1 Model 57152-40X 230 Vac (±15%) 50–60 Hz, 7W DC Power Output (AC Models Only) 1 Output 12 Vdc (±25%), 100 mA maximum (includes all line and load variations) Environment 1 Operating temperature 32° to 131°F (0° to 55°C) Storage temperature –4° to158°F (–20° to 70°C) 1 Operating humidity 85% relative, non-condensing NEMA 4 rating When mounted with gasket provided 1 Ratemeter Type 1/Tau 1 Digits Five with overrange indication Scaler range 0.00001 to 99999 1 Decimal point Five positions, programmable Average time 0.1 to 99.9 seconds, programmable 1 Zero time 0.1 to 99.9 seconds, programmable Accuracy ±0.015% of reading 1 Note 1 1 The accuracy of the ratio calculation is dependent upon the resolution of the displayed rates, which are calculated as rounded integers. The ratio calculation treats the displayed rate as integers and the result is displayed as a rounded integer. A and B scalers should be adjusted for maximum resolution. 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-85 Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters General Specifications, continued 1 Maximum Rate Input Frequencies 1 Maximum frequencies All maximum frequencies listed are with a square wave input (50-50 duty cycle) Contact Input 1 Contact input 40 Hz 1 Solid-State Input Sinking sensor (all DIPs off) 7.3 kHz 1 Sourcing sensor (push-pull output) High threshold (DIPs 1 and 2 on, 3 and 4 off) 0–5V, single input 50 kHz 1 0–5V, two inputs 30 kHz (each input) 0.5–4.5V, single input 40 kHz 1 0.5–4.5V, two inputs 30 kHz (each input) 0–15V, two inputs 22 kHz (each input) 1 Low threshold (all DIPs on) –1 to +1V, single input 27 kHz 1 –2 to +2V, single input 43 kHz < > –3 to +3V, single input 60 kHz 1 <–2 to >+2V, two inputs 30 kHz (each input) Rate Inputs 1 Sink Impedance 4.6k ohms to +5 Vdc 1 Voltage High 3.5 to 34.0, low 0.0 to 1.9 Vdc 1 Source (high) Impedance 2.3k ohms to common 1 Voltage High 3.5 to 17.0 Vdc, low 0.0 to 1.9 Vdc Source (low) 1 Impedance 2.3k ohms to common DC voltage High 0.63 to 17.0 Vdc, low –17.0 to –0.6 Vdc 1 AC voltage 17 Vac (48V peak-peak) maximum Control Inputs 1 Impedance 4.7k ohms to +5 Vdc 1 Voltage High +3.7 to +24 Vdc, low 0.0 to 0.9 Vdc Response Min, low 15 ms, min, high 15 ms 1 Transistor Outputs (x2 for 5715X-401; x4 for 5715X-405) Type NPN open collector with transient protection 1 Max. voltage (OFF state) 30 Vdc 1 Max. current (ON state) 200 mA at 1.3 Vdc Communication 1 Type RS-485 Format One start bit, seven data bits (ASCII), one parity bit, one stop bit 1 ® Protocol Opto-22 compatible Speed 300, 1200, 2400, 4800, 9600, 19200 baud 1 Parity Odd, even, none (space transmitted, ignore received) 1 Analog Output (Models 5715X-401 Only) Range 0–10 Vdc ± 0.2% at 5 mA 1 DAC resolution 12 bit Connections 1 Type Dual depluggable screw terminal strips 2 Conductor size 14–22 AWG (2.1–0.38 mm ), 600V, solid, stranded or fused (preferred) 1 1 1 V13-T1-86 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.3 Tachometers/Ratemeters Dimensions 1 Approximate Dimensions in Inches (mm) 1 Ambassador Series Ratemeters 1 A 12345 1 R/M 2.946 ±0.015 (74.83 ±0.38) UNL RUN AKN 1 CLR PGM • EXIT ENT SEL 1 2.946 ±0.015 5.60 ±0.03 1 (74.83 ±0.38) (142.24 ±0.76) 1 1 1 2 2 3 1 3 4 4 Panel Cutout 5 5 2.677 ±0.028 Max. Panel 6 6 (68.00 ±0.70) 7 7 1 Thickness 8 8 9 0.50 (12.7) 9 10 10 11 1 12 2.677 ±0.028 1 (68.00 ±0.70) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-87 Counters, Panel Meters, Tachometers and Timers 1.4 Digital Panel Meters Contents Digital Panel Meters 1 Description Page Count Controls/Preset Counters 1 E5-324-E Series. . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-89 1 Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-91 Learn 1 Online 1 1 1 1 1 1 1 Product Overview Product Selection Guide Digital Panel Meters are 1 Digital Panel Meters found anywhere a process variable needs to be Panel Cutout 1 indicated. Volts, current, Characteristics in Inches (mm) Page pressure, volume, E5-324-E Bright, easy-to-read LED in 1/32 DIN package 0.870 x 1.772 V13-T1-89 1 temperature and frequency (22 x 45) Programmable scaling of inputs are typical applications. The Input for display-hold product’s short depth makes 1 it flexible and accommodating 24 Vdc power to panel builder needs. A 1 variety of input and output Eclipse Six-digit, super bright LED display 1.772 x 3.780 V13-T1-91 options allows DPMs to be (45 x 96) 1 used virtually anywhere. Multiple models available: DC voltage, AC voltage, DC current, AC current, 5A AC current, 4–20 mA/0–10V process meter Typical Application Various output options including relay, analog and RS-485 1 ● Monitor current draw from motor to identify potential 1 failures ● Display pressure reading 1 from transducer with high- pressure alarm 1 ● Display system voltage and detect under voltage or 1 over voltage conditions 1 1 1 1 1 1 1 1 V13-T1-88 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.4 Digital Panel Meters E5-324-E Series 1 Product Description Features Standards and Certifications ● ● ● Eaton’s most compact panel Galvanic isolation with Compact display for analog UL recognized 1 meter provides an easy-to- protection against incorrect standard signals ● CE marked read LED in a very small polarity ● Display range –19.999 to 1 package. ● Automatic MIN/MAX value 99.999 with zero blanking detection ● Modern industrial design 1 ● Freely programmable ● Input for display-hold characteristic curve end 1 points ● Input Range— 1 ● Single current measuring input (0/4–20 mA) 1 ● Single voltage measuring input (0/2–10V) 1 1 Product Selection 1 E5-324-E0402 Digital Panel Meter E5-324-E0402 Description Catalog Number 1 LED digital panel meter, 24 x 48 mm E5-324-E0402 1 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Supply voltage 10–30 Vdc, galvanically isolated with integrated protection against incorrect polarity 1 Current consumption Max. 50 mA Display Five-digit display, red seven-segment LEDs; 0.31 in (8 mm) high 1 Measuring rate Two measurements/second Data backup EEPROM 1 Housing Housing for control panel 1.898 x 0.94 in (48 x 24 mm); acc. to DIN 43 700, RAL 7021, dark gray 1 Ambient temperature 14° to 122° F (–10° to 50°C) EMC According to EC EMC directive 89/36/EEC 1 Interference emissions EN 61 000-6-4/EN 55011 Class B 1 Interference resistance EN 61 000-6-2 Protection IP65 (front) 1 Input current measurement 0–20 mA, 4–20 mA, voltage drop max. 1.5 Vdc Input voltage measurement 0–10V, 2–10V 1 Input resistance approx. 1M ohm Max. input signal level 30 Vdc 1 Control inputs High 4–30 Vdc 1 Low 0–2 Vdc 1 Resolution 14 bits Error <0.1% for the whole measuring range at an ambient temperature of 68°F (20°C) 1 Weight: Approx 1.76 oz (50g) Connection technique Screw terminal, pitch 0.2 in (5.08 mm), seven-poles 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-89 Counters, Panel Meters, Tachometers and Timers 1.4 Digital Panel Meters Dimensions 1 Approximate Dimensions in Inches (mm) 1 E5-324-E Series 0.87 x 1.77 Max. 0.76 1 1.89 (22.0 x 45.0) (19.3) Connections: (48.0) 1 0.94 1 (24.0) Panel Cut-Out: 1 0.16 + 0.01 + 0.02 0.87 x 1.77 (4.0) + 0.3 + 0.6 (22.2 x 45 ) 1 2.32 0.26 (59.0) (6.5) 1 + 0.02 2.09 1.97 + 0.6 1 (53.0) (50 ) 1 + 0.02 1.10 0.98 x 1.97 0.98 + 0.5 (28.0) (25 x 50) (25 ) 1 1 0.04 Panel Cut-Out (1.0) 0.16 1 (4.0) 1 + 0.02 2.20 1.97 + 0.6 (56.0) (50 ) 1 + 0.004 1.57 1.26 0.98 x 1.97 + 0.02 1 1.26 0.98 + 0.1 (40) (32) (25 x 50) + 0.5 (32 ) (25 ) 1 0.04 M3 (1.0) 1 Panel Cut-Out 0.16 (4.0) 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-90 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.4 Digital Panel Meters Eclipse Series 1 Product Description Features Standards and Certifications ● ● ● Eaton’s Eclipse Series panel Four full digits Maximum/minimum data UL and cUL listed 1 meter features a high- hold ● ● 1/8 DIN Size CE marked visibility LED and is available ● ● Optional analog, relay and 1 Red, LED display with a variety of input and RS-485 outputs ● 0.56 in (14 mm) high scaling options. ● NEMA 4X 1 characters ● Depluggable terminal ● Scalable display blocks ● 1 Flashing alarms 1 Eclipse Series Panel Meter 1 1 1 1 1 Catalog Number Selection 1 Eclipse Series 1 5770 X –4X X 1 1 Power Supply Output Option 0 = DC (9–30 Vdc) 0 = No option 1 1 = AC (85–265 Vac) 1 = Dual relay 2 = Analog output (4–20 mA and 0–10V) 1 3 = Dual relay, analog output (4–20 mA and 0–10V) Input Option 4 = RS-485 communications 0 = DC volt 4 = 5A AC TRMS 5 = Dual relay, RS-485 1 1 = AC volt TRMS 5 = Process (4–20 mA, 0–10V, 1–5V) 6 = Analog, RS-485 (4–20 mA and 0–10V) 2 = DC amp 6 = Temperature (J, K, T, PT100 RTD) 7 = Dual relay, analog, RS-485 (4–20 mA and 0–10V) 3 = AC amp TRMS 1 Note 1 1 Output options 0, 2, 4 are not available for models -41X and -43X. 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-91 Counters, Panel Meters, Tachometers and Timers 1.4 Digital Panel Meters Product Selection 1 Eclipse Digital Panel Meter Eclipse Series Panel 1 Meter Description Catalog Number 9–30 Vdc, DC volt 57700400 1 9–30 Vdc, DC volt, relay out 57700401 1 9–30 Vdc, DC volt, analog out 57700402 9–30 Vdc, DC volt, relay out, analog out 57700403 1 9–30 Vdc, DC volt, RS-485 57700404 9–30 Vdc, DC volt, RS-485, relay out 57700405 1 9–30 Vdc, AC volt, relay out, analog out 57700413 9–30 Vdc, DC amp 57700420 1 9–30 Vdc, DC amp, relay out 57700421 1 9–30 Vdc, DC amp, analog out 57700422 9–30 Vdc, AC amp, relay out 57700431 1 9–30 Vdc, 5A AC 57700440 9–30 Vdc, 5A AC, relay out 57700441 1 9–30 Vdc, 5A AC, analog out 57700442 85–265 Vac, DC volt 57701400 1 85–265 Vac, DC volt, relay out 57701401 1 85–265 Vac, DC volt, analog out 57701402 85–265 Vac, DC volt, analog out, relay out 57701403 1 85–265 Vac, DC volt, RS-485 57701404 85–265 Vac, DC volt, RS-485, relay out 57701405 1 85–265 Vac, AC volt 57701410 1 85–265 Vac, AC volt, relay out 57701411 85–265 Vac, AC volt, analog out 57701412 1 85–265 Vac, AC volt, relay out, analog out 57701413 85–265 Vac, AC volt, RS-485, analog out, relay out 57701417 1 85–265 Vac, DC amp 57701420 85–265 Vac, DC amp, relay out 57701421 1 85–265 Vac, DC amp, analog out 57701422 1 85–265 Vac, DC amp, relay out, analog out 57701423 85–265 Vac, DC amp, RS-485, analog out, relay out 57701427 1 85–265 Vac, AC amp 57701430 85–265 Vac, AC amp, relay out 57701431 1 85–265 Vac, AC amp, analog out 57701432 1 85–265 Vac, AC amp, analog out, relay out 57701433 85–265 Vac, AC amp, RS-485 57701434 1 85–265 Vac, 5A AC 57701440 85–265 Vac, 5A AC, relay out 57701441 1 85–265 Vac, 5A AC, analog out 57701442 85–265 Vac, 5A AC, analog out, relay out 57701443 1 85–265 Vac, 5A AC, RS-485, analog out 57701446 1 1 1 1 1 V13-T1-92 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.4 Digital Panel Meters Eclipse Process 1 Description Catalog Number 9–30 Vdc 57700450 1 9–30 Vdc, relay out 57700451 9–30 Vdc, analog out 57700452 1 9–30 Vdc, relay out, analog out 57700453 1 9–30 Vdc, RS-485 57700454 85–265 Vac 57701450 1 85–265 Vac, relay out 57701451 85–265 Vac, analog out 57701452 1 85–265 Vac, analog out, relay out 57701453 1 85–265 Vac, RS-485 57701454 85–265 Vac, RS-485, relay out 57701455 1 85–265 Vac, RS-485, analog out 57701456 85–265 Vac, relay out, analog out, RS-485 57701457 1 Eclipse Temperature 1 Description Catalog Number 1 9–30 Vdc 57700460 9–30 Vdc, relay out 57700461 1 9–30 Vdc, relay out, analog out 57700463 85–265 Vac 57701460 1 85–265 Vac, relay out 57701461 1 85–265 Vac, analog out 57701462 85–265 Vac, relay out, analog out 57701463 1 85–265 Vac, RS-485 57701464 85–265 Vac, RS-485, analog out, relay out 57701467 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-93 Counters, Panel Meters, Tachometers and Timers 1.4 Digital Panel Meters Technical Data and Specifications 1 General Specifications 1 Description Specification Input Power 1 AC powered models (57751-4XX) Input power 85–265 Vac, 47–63 Hz, 20 VA 1 External fuse 0.2A, 250 Vac, time delay (T200 mA, 250V) 1 Isolation dielectric strength 2300 Vac DC powered models (57750-4XX) 1 Input power 9-30 Vdc, 12 VA External fuse 2.0A, 50 Vdc, time delay (T2A, 50V) 1 Reverse voltage protection Yes Isolation dielectric strength 2300 Vac to signal inputs and relays, 500 Vac to RS-485 and analog outputs 1 Human Interface 1 Display ±4 full digits Type 0.56 in (14 mm) high, seven segment, red LED 1 Update time 0.4 seconds Alarm Flashing display 1 Indicator One red LED program/calibration indicator with max./min. capture and hold Data Retention 1 Memory type EEPROM, no batteries required 1 Duration 100 years Signal Input 1 DC voltage models (5770X-40X) Range ±199.9m Vdc, ±1.999 Vdc, ±19.99 Vdc, ±199.9 Vdc, DIP switch selectable 1 Impedance 1M ohm Overrange 750 Vdc/530 Vac except 220 Vdc/Vac on 199.9 mV range 1 Accuracy ±0.1% of reading, ±0.03% FS, ±0.5 digit, and ±80 PPM/°C 1 AC voltage models (5770X-41X) Range 199.9 m Vac, 1.999 Vac, 19.99 Vac, 199.9 Vac, DIP switch selectable, all ranges true rms 1 Frequency 40 to 1000 Hz Impedance 1M ohm (capacity coupled) 1 Overrange 750 Vdc/530 Vac except 220 Vdc/Vac on 199.9 mV range Accuracy ±0.5% of reading, ±0.13% FS, ±0.5 digit, ±180 PPM/°C for crest factor = 1; plus ±0.7% for 1 crest factor = 1 to 3; and ±2.5% for crest factor = 5 DC current models (5770X-42X) 1 Range ±199.9 μA DC, ±1.999 mA DC, ±19.99 mA DC, ±199.9 mA DC, DIP switch selectable Impedance 199.9 mV/selected range 1 Overrange 30 mA (199.9 μA range), 100 mA (1.999 mA range), 300 mA (19.99 mA range), 1A (199.9 mA range) 1 Accuracy ±0.1% of reading, ±0.03% FS, ±0.5 digit, and ±120 PPM/°C 1 AC current models (5770X-43X) Range 199.9 μA AC, 1.999 mA AC, 19.99 mA AC, 199.9 mA AC, DIP switch selectable, all ranges true rms 1 Frequency 40 to 1000 Hz 1 Impedance 199.9 mV/selected range (shunt output capacitive coupled) Overrange 30 mA (1199.9 μA range), 100 mA (1.999 mA range), 300 mA (19.99 mA range), 1A (199.9 mA range) 1 Accuracy ±0.5% of reading, ±0.13% FS, ±0.5 digit, and ±200 PPM/°C for crest factor = 1; plus ±0.7% for crest factor = 1 to 3; and ±2.5% for crest factor = 5 1 1 1 V13-T1-94 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.4 Digital Panel Meters General Specifications, continued 1 Description Specification Signal Input, continued 1 5A AC models (5770X-44X) Range 5A AC, true rms 1 Frequency 40 to 1000 Hz 1 Impedance 0.02 ohm (shunt output capacitive coupled) Overrange 10A maximum 1 Accuracy ±0.4% of reading, ±0.13% FS, ±0.5 digit, and ±200 PPM/°C for crest factor = 1; plus ±0.7% for crest factor = 1 to 3; and ±2.5% for crest factor = 5 1 Process models (5770X-45X) Range 4–20 mA DC, 0–10 Vdc, 1–5 Vdc; separate input terminals for voltage and current signals 1 Impedance 100 ohms (current input) and 1.27M ohms (voltage input) Overrange 50 mA maximum (current input) and 100V maximum (voltage input) 1 Power output 24 Vdc ±10%, 90 mA max, short-circuit protected Accuracy ±0.1% of reading, ±0.03% FS, ±0.5 digit, and ±80 PPM/°C 1 Optional Outputs 1 Relay board Dual relay 1 set of Form C contacts each 1 Contact rating 5A, 250 Vac or 30 Vdc Isolation dielectric strength 2300 Vac 1 Analog retransmission Output signals 4–20 mA (<750 ohms) and 0–10V (>2500 ohms) 1 Accuracy 0.13% FS, 100 PPM/°C, 0.07% FS change with 4–20 mA load, ±0.3% FS for 4–20 mA output, only after exposure to 85% relative humidity 1 Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power input; 500 Vac to RS-485 and DC power inputs 1 RS-485 serial communication Baud rate 1200, 2400, 4800, 9600 or 19,200, programmable 1 Parity Even, odd or no parity Address range 00 to 99 decimal 1 ® Protocol Opto 22 compatible 1 Isolation dielectric strength 2300 Vac to signal inputs, relays, and AC power input; 500 Vac to analog outputs and DC power inputs 1 Environmental Operating environment Indoor use to 2000 meters 1 Temperature Operating 32° to 122°F (0° to 50°C) 1 Storage –4° to 158°F (–20° to 70°C) Humidity 0 to 85% RH, non-condensing 1 Vibration 2.5 Gs, 30 to 200 Hz Shock 30 Gs, 11 ms half sinewave 1 EMC/EMI Per EN 61326-1 industrial 1 Front panel NEMA 4X when mounted with gasket provided Agency approval CE EMC immunity and emissions requirements were met using shielded wiring on the 1 RS-485, analog output and signal input lines. The shields were connected to earth ground at the Eclipse end of the shields. 1 Conducted emissions requirements were met assuming that the AC signal input would not be connected directly to the AC mains. The measurement error during RF immunity testing was less than ±5% of full scale. 1 In addition, models with an AC signal input had measurement error of less than +25% of full scale during RF immunity testing of the RS-485 at frequencies below 1 MHz. 1 Pollution degree 2 Overvoltage Category II 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-95 Counters, Panel Meters, Tachometers and Timers 1.4 Digital Panel Meters Dimensions 1 Approximate Dimensions in Inches (mm) 1 Eclipse Series 1 1 2.19 1.772 ±0.02 (55.6) (45 ±0.6) 1 PGM 1 4.04 1 (102.6) 3.622 ±0 .031 (92.0 ±0.8) Panel Cutout 1 Max. Panel Thickness 1 0.19 (4.8) 1 1 3.63 (92.2) 1 3.31 (84.1) 1 0.27 (6.9) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-96 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Contents Timers/Hour Meters 1 Description Page Timers/Hour Meters 1 Product Selection Guide . . . . . . . . . . . . . . . . . . V13-T1-98 Electronic Timers/Hour Meters . . . . . . . . . . . . . V13-T1-99 1 Electromechanical Timers/Hour Meters . . . . . . V13-T1-105 1 Learn Online 1 1 1 1 1 1 1 Typical Application Product Overview ● Elapsed time indication for Timers are used in 1 interval maintenance of applications where time itself construction and is the main focus. These agricultural equipment 1 include simple knowledge of ● how long a machine has been Usage metering for running to determine determining charges on 1 machine maintenance, for rental equipment example, (elapsed time) to ● Controlled process timing 1 knowing when to change an for adhesive application/ elevator cable (cable life and curing equipment 1 safety). Timers generally have the ability to stop and 1 then to continue on from the point at which they stopped. Timer relays are used in 1 applications where an output is required to make 1 something happen at a predetermined point in time 1 (to stop or start the process). 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-97 Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Product Selection Guide 1 Timers/Hour Meters 1 Panel Cutout Characteristics in Inches (mm) Page 1 E5-_24-E Compact device with bright, LED display 0.870 x 1.772 V13-T1-44 (22 x 45) Multiple functions available: count, time, rate, multifunction, double- 1 function 24 Vdc Power 1 E5-496-E Economical, multifunction display 1.772 x 3.622 V13-T1-49 1 (45 x 92) Large, LED characters AC or DC power options 1 1 E5-224-C Non-replaceable battery (minimum eight-year life) 0.870 x 1.772 V13-T1-100 1 (22 x 45) Compact, low cost and high efficiency Eight-digit LCD timer 1 Manual or electrical reset Various timing modes (Hr/Min/Sec) 1 Hour Meters Compact, low-cost LCD and electromechanical elapsed time meters Various V13-T1-105 Various power options for almost any power supply 1 1 1 1 Hour Meter/Counter Combination counter consists of time meter and adding counter in one 1.988 (50.5) dia. or V13-T1-111 DIN rail Without reset 1 High shock resistance Magnified figures 1 Protection IP52 (front) Data retention if power is lost 1 Long service life UL Approved 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-98 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Contents Electronic Timers/Hour Meters 1 Description Page Electronic Timers/Hour Meters 1 1/32 DIN LCD—Timers . . . . . . . . . . . . . . . . . . . V13-T1-100 E42DI24/E42DIR Series . . . . . . . . . . . . . . . . . . V13-T1-103 1 Electromechanical Timers/Hour Meters . . . . . . . . V13-T1-105 1 1 1 1 1 1 1 1 Electronic Timers/Hour Meters Product Overview Features Standards and Certifications 1 ● ● Eaton’s electronic hour Reset or non-reset UL recognized meters are a simple and ● ● Variety of power options CE 1 effective way to monitor ● LCD displays equipment on time. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-99 Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters 1/32 DIN LCD—Timers 1 Product Description Features Standards and Certifications ● ● ● 1 Simple battery-powered Low price and high High voltage input for UL recognized timers provide an easy-to- efficiency 10–260 Vac/Vdc voltage ● CE marked read LCD and a variety of pulses ● Large eight-digit LCD 1 timing display options. ● display, height of the IP65 figures 0.31 in (8 mm) ● Screw terminals, 1 ● Different time ranges from RM 5 mm 0.1 second to 100,000 ● Lifetime of the battery 1 hours approximately eight years ● 0.1 second synchronization ● Locking of the reset key 1 makes it suitable for very ● Operating temperature short activation times 14° to 140°F (–10° to 60°C) 1 1 Product Selection 1 1/32 DIN LCD Timers 1 E5-224-C04_ Description Catalog Number 1 Eight-Digit LCD Timer, Battery Power Hours/minutes, 0.94 x 1.89 in (24 x 48 mm) E5-224-C0440 1 Hours/minutes, 10–260V input, 0.94 x 1.89 in (24 x 48 mm) E5-224-C0448 Minutes/seconds, 0.94 x 1.89 in (24 x 48 mm) E5-224-C0450 1 Minutes/seconds, 10–260V input 0.94 x 1.89 in (24 x 48 mm) E5-224-C0458 1 Technical Data and Specifications 1 General Specifications 1 Description Specification 1 Power supply Non-replaceable lithium battery (lifetime approximately eight years at 68°F (20°C) Display LCD, eight-digits 1 Figure size 0.31 in (8 mm) high Counting direction Adding 1 Display range 1 Time range 99999h 59m (134) Display 1 Time range 99999.99h (134) 1 Display Time range 9999h 59m 59s (135) 1 Display 1 Time range 9999999.9s (135) Display 1 Reset Manual and electrical 1 1 1 1 1 V13-T1-100 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters General Specifications, continued 1 Description Specification Timer inputs, DC versions (max. 30 Vdc) 1 Timer input NPN or PNP depending on the type Switching level 1 NPN low 0–0.7V NPN high 3–30 Vdc 1 PNP low 0–0.7V 1 PNP high 4–30 Vdc Counting start 1 NPN For low signal at the timer input PNP For high signal at the timer input 1 Timer inputs, high voltage version (10–260 Vdc/Vac) Timer input Optocoupler input max. 30 Hz 1 Min. pulse time 16 ms Switching level 1 Low 0–2 Vdc/Vac 1 High 10–260 Vdc/Vac Counting start For high signal at the timer input 1 Time range change (mode) Contact input—open collector (switching at 0V) 1 NPN low 0–0.7V NPN high 3–5 Vdc 1 Time range Depending on the circuit Reset Input (only DC and high voltage) 1 Minimum pulse time 1 DC 50 ms High voltage 10 ms 1 Contact input (DC) NPN low 0–0.7V 1 NPN high 3–30 Vdc High voltage input 10–260 Vdc/Vac 1 Reset locking input (for DC and AC), electrical reset key locking 1 Input not active Reset key locked Contact input Open collector NPN (switching at 0V) 1 Switching level NPN low 0–0.7V 1 NPN high 3–5 Vdc 1 Interference emissions EN 55011 Class B, EN 61 000-6-2, EN 61010 Section 1 (only AC versions) Housing Dark gray RAL 7021 1 Operating temperature 14° to 131°F (–10° to 55°C) Ambient temperature 14° to 140°F (–10° to 60°C) 1 Storage temperature –4° to 158°F (–20° to 70°C) Protection IP65 (from front) 1 Weight Approx. 1.76 oz (50g) 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-101 Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Dimensions 1 Approximate Dimensions in Inches (mm) 1 1/32 DIN LCD Timers MAX. 1.89 (19.3) 1 1.89 (48) 1 0.87 x 1.77 0.94 (22 x 45) (24) 1 0.11 (2.8) 1 1.88 (47.7) 0.12 (3) 1 + 0.024 1.77 + 0.6 (45 ) 1 1 + 0.012 1.77 +0.3 (22.2 ) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-102 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters E42DI24/E42DIR Series 1 Product Description Features Standards and Certifications ● ● ● Simple LCD hour meters with Solid-state hour meters Time accumulation UL recognized 1 flexible input voltages indicated by flashing ● ● Record and display up to CE compliant hourglass icon 99,999.9 hours, rollover 1 ● and continue timing Memory will arm only ● when power has been EEPROM memory can 1 applied for 5 seconds retain data for 25+ years 1 1 Product Selection 1 E42DI24/E42DIR Series Elapsed Time Meters Description Catalog Number 1 E42DIR_ Round LCD 1 Elapsed hour meter, 48–150 Vdc/100–230 Vac E42DIR48230 Elapsed hour meter with reset, 48–150 Vdc/100–230 Vac E42DIR48230R 1 Elapsed hour meter, 12–48 Vdc/20–60 Vac E42DIR1260 E42DI24_ Rectangular LCD 1 Elapsed hour meter, 48–150 Vdc/100–230 Vac E42DI2448230 1 Elapsed hour meter, with reset, 48–150 Vdc/100–230 Vac E42DI2448230R Elapsed hour meter, 12–48 Vdc/20–60 Vac E42DI241260 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Function Solid-state hour meter Power supply 1 E42DIXX1260X 12–48 Vdc ±25%/20–60 Vac ±25% E42DIXX48230X 48–150 Vdc +23%–25%/100–230 Vac +17%–25% 1 Frequency range 48–440 Hz Display Six-digit LCD, 0.20 in (5 mm) 1 Accuracy ±0.1% Recording/display capacity 99,999.9 hours 1 Resolution 0.1 hour (6 minutes) Current consumption max. at nominal voltage 1 E42DIXX1260X 0.8 mA at 12 Vdc 5.0 mA at 48 Vdc 1 0.5 mA at 20 Vac 2.5 mA at 60 Vac 1 E42DIXX48230X 0.8 mA at 48 Vdc 1 2.5 mA at 150 Vdc 0.9 mA at 100 Vac 1 2.0 mA at 230 Vac Input impedance minimum (pins 3 and 4) 1 E42DIXX1260X 70k ohms E42DIXX48230X 480k ohms 1 Operating temperature –40° to 185°F (–40° to 85°C) Storage temperature –58° to 194°F (–50° to 90°C) 1 Weight E42DIRXXXXXX 1.94 oz (55g) 1 E42DI24XXXXXX 0.78 oz (22g) 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-103 Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Dimensions 1 Approximate Dimensions in Inches (mm) 1 E42DI24/E42DIR Series U Clamp for 1 0.03 – 0.25 (7.6 – 6.4) Washer Panel Thickness 1 Thumbnut 0.16 (4.0) Black Bezel 1 QUARTZ HOURS 1 — Terminal 0.25 10 1 (6.4) Max. 1 0.35 (8.9) 1 Dia. 2.30 Dia. 2.06 Max. (58.4) Max. (52.3) Max. 0.52 (13.2) 1.13 (28.6) Max. 1 Max. 1 1.13 1.40 Terminal (28.7) 0.06 1 (35.6) 0.25 (6.4) (1.5) +0.01 HOURS 0.95 -0.00 0.89 1.22 1 +0.25 0.93 (23.6) (24.1 -0.00) (22.6) (31.1) 1/10 +0.01 1 1.45 -0.00 0.18 1.75 +0.25 (4.7) (36.8 -0.00) 0.71 (44.5) (18) 1 2.00 (53.1) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-104 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Contents Electromechanical Timers/Hour Meters 1 Description Page Electronic Timers/Hour Meters . . . . . . . . . . . . . . . V13-T1-99 1 Electromechanical Timers/Hour Meters 1/16 DIN Hour Meters . . . . . . . . . . . . . . . . . . . V13-T1-106 1 71.1 Round Hour Meters . . . . . . . . . . . . . . . . . V13-T1-109 1 Hour Meter/Counter . . . . . . . . . . . . . . . . . . . . . V13-T1-111 1 1 1 1 1 1 1 Electromechanical Timers/Hour Meters Product Overview Features Standards and Certifications 1 ● ● Eaton’s electromechanical Non-resettable UL recognized hour meters are available in a ● ● Always readable display CE 1 variety of configurations and provide a cost-effective way 1 to monitor equipment on time. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-105 Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters 1/16 DIN Hour Meters 1 Product Description Typical Application Features Standards and Certifications ● ● ● 1 Eaton’s most cost-effective General elapsed time High shock resistance UL recognized elapsed time meter. Features ● ● Service interval for Without reset IP65 protection against water measurement systems— 1 ● Small dimension intrusion. ● Respiratory ventilators ● Magnified figures 1 ● Oxygen machines ● Protection IP65 ● Dialysis machines ● Data retention if power is 1 ● Small appliances lost ● ● UV lamps Long service life 1 ● ● Display panels in cars Optional mounting position 1 Product Selection 1 1/16 DIN Hour Meters 7-T-65-4848PM-40_ 1 Description Catalog Number 10–30 Vdc, 1.89 x 1.89 in (48 x 48 mm) 8-T-65-4848PM-402 1 100–130 Vac, 1.89 x 1.89 in (48 x 48 mm) 7-T-65-4848PM-406 1 1 DIN Rail Adapter 1 T4848DINADAPT Description Catalog Number 1 DIN rail adapter for DIN electromechanical hour meter T4848DINADAPT 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-106 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Technical Data and Specifications 1 General Specifications 1 Description Specification 2 Electrical connection Clamp terminal for cable diameter up to 14 AWG (2.5 mm ), 1 tightening torque max. 0.59 lb-ft (0.8 Nm) Power consumption 1 10–30 Vdc Approx. 500 mW 100–130 Vdc Approx. 750 mW 1 Rated voltages 100–130 Vac, 50 or 60 Hz 10–30 Vdc 1 On time 100% 1 Display Seven at AC 99999.99 1 Eight at DC 999999.99 Accuracy 1 AC Supply frequency + 30 ms DC <0.003% (24h) 1 Count mode Adding 1 Figure size 0.16 in (4 mm) high Color of figures White and red-on-black 1 Ambient temperature 5° to 122°F (–15° to 50°C) Mounting position Any 1 Protection IP65 Housing Plastic 1 Weight 1.7 oz (48g) 1 Operating indicator of the running time meter AC Fast rotating wheel with red dashes 1 DC 1/100h display turns continuously by 1-digit in 36 seconds Test voltage 2000 Vac, 50 Hz for AC counters 1 Options Further voltages on request Color of housing Gray 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-107 Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Dimensions 1 Approximate Dimensions in Inches (mm) 1 1/16 DIN Hour Meters 1 1 Dia. 1.97 (50) 1 1 1 1.77+0.02 (45+0.6) 1.89 (48) SQ. 1.77 (45) SQ. 0.35 (9) SQ. Max. Screw 1 0.28 Terminal Panel Cut-Out 1.10 (7) (28) 1 1 DIN Rail Adapter 1 1.91 (48.5) 1 1 2.42 (61.5) 1 0.75 1 (19) 1.62 (41.1) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-108 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters 71.1 Round Hour Meters 1 Product Description Typical Application Features Standards and Certifications ● ● ● Eaton’s 6-T-3H hour meters General elapsed time Six-digit hour meter for UL recognized 1 are heavy-duty elapsed time round panel cut-out ● Utility vehicles meters with NEMA 4X ● ● Low cost 1 Construction machines protection. ● High shock resistance ● Generators ● 1 ● Low power consumption Fork-lift trucks ● Small dimension ● Car washes ● 1 ● Magnified figures Outside areas ● Waterproof 1 ● NEMA Type 4X rating ● Data retention if power is 1 lost ● Available in 50 pc. bulk 1 package 1 Product Selection 1 71.1 Round Hour Meters 6-T-3H-508RPM-40_ 1 Description Catalog Number 115 Vac, 2.80 in (71.1 mm) round 6-T-3H-508RPM-406 1 10–80 Vdc, 2.80 in (71.1 mm) round 6-T-3H-508RPM-402 1 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Electrical connection Flat pins 0.8 x 6.3 1 Power consumption AC Max. 0.4 VA 1 12 Vdc Max. 0.08W 48 Vdc Max. 0.7W 1 Rated voltages 115 Vac ±10%, 50/60 Hz, 10–80 Vdc On time 100% 1 Display Six-digits, 99999.9h Count mode Adding 1 Figure size 0.14 in (3.5 mm) high Reset None 1 Ambient temperature –22° to 149°F (–30° to 65°C) Mounting position Any 1 Protection IP65 Housing Plastic 1 Error <0.02% over the full range 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-109 Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Dimensions 1 Approximate Dimensions in Inches (mm) 1 71.1 Round Hour Meter Dia. 2.54 1 (64.5) Dia. 0.15 0.03 x 0.25 Dia. 2.44 1 (3.8) 120° (0.8 x 6.3) (62) Dia. 1 0.13 Dia. 2 (3.3) (50.8) 1 1.68 Dia. 2 (42.7) (50.8) 1 1 Panel Cut-Out Dia. 2.80 0.47 1.26 0.21 (71.1) (12) (32) (5.3) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-110 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Hour Meter/Counter 1 Product Description Typical Application Features Standards and Certifications ® ● ● ● Eaton’s CEC series General counting Combination counter cRU us certified 1 combination meters provide consists of time meter and ● ● Pump control panels CE marked an event counter and elapsed adding counter in one ● 1 Service interval for time meter is one compact ● Without reset measurement systems unit. ● (respiratory ventilators, High shock resistance 1 oxygen machines, dialysis ● Magnified figures machines) ● Protection IP52 (front) 1 ● Small appliances ● Data retention if power is ● UV lamps lost 1 ● Display panels in cars ● Long service life 1 1 Product Selection 1 Hour Meter/Counters CEC-…-406 Description Catalog Number 1 Combination hour meter/counter, 55 mm square front panel mount, CEC-55PM-406 100–130 Vac, 60 Hz 1 Combination hour meter/counter, 48 mm DIN rail mount, 100–130 Vac, 60 Hz CEC-48DR-406 1 1 Technical Data and Specifications 1 General Specifications Description Specification 1 Electrical connection Flat pin 0.8 x 6.3 mm with screw terminal, tightening torque max. 0.8 Nm Power consumption 1 100–130 Vac 60 Hz, approx. 1.43 VA Count mode Adding 1 Figure size 0.16 x 0.07 in (4 x 1.7 mm) Color of figures 1 Hour White on black Decimal Red on black 1 Running time meter operating indicator Fast rotating wheel with red dashes; 99999.99 hour Accuracy AC Supply frequency ±30 ms 1 Reset None Ambient temperature 5° to 122°F (–15° to 50°C) 1 Mounting position Any Color of housing Black 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-111 Counters, Panel Meters, Tachometers and Timers 1.5 Timers/Hour Meters Dimensions 1 Approximate Dimensions in Inches (mm) 1 DIN Rail Mount 2.106 1 (53.5) 0.197 (5.0) 1 1 h 2.421 (61.5) 1 0.047 1 (1.2) SQ 1.91 0.748 (48.5) (19.0) 1 1 Front Panel Mount 0.256 (6.5) Max. 1 1 1 h 1 1 0.047 (1.2) 1 SQ 2.166 Dia. 1.988 (55.0) 0.374 (9.5) (50.5) 1.122 1 (28.5) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-112 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.6 Flow Totalizers, Transmitters and Controls Contents Flow Totalizers, Transmitters and Controls 1 Description Page Flow Totalizers, Transmitters and Controls 1 Product Selection Guide . . . . . . . . . . . . . . . . . . V13-T1-113 Eclipse Series . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-114 1 Learn 1 Online 1 1 1 1 1 1 1 Product Overview Flow products are used in a Application Example 1 variety of applications where liquid gas flow needs to be 1 monitored or controlled. Eaton offers models for flow total, flow rate and flow batch 1 control. Several optional Flow Sensor outputs allow great flexibility 1 to meet most application needs. 1 Typical Application 53300-405 1 Totalizer/Ratemeter In many processes, it is desirable to know both the 1 total quantity of product being produced and the rate 1 at which the product is being produced. 1 In the illustration at right, the Liquid output of a turbine flow 1 sensor is connected to a totalizer/ratemeter. The flow 1 sensor produces a known number of pulses per gallon (or other unit of measure). 1 The instrument scales these pulses into the desired units 1 Product Selection Guide of flow volume (gallons, liters, barrels, etc.), and flow 1 rate (gallons/minute, barrels/ Totalizers hour, etc.). Panel Cutout 1 Characteristics Typical Applications in Inches (mm) Page Eclipse Six-digit, super bright LED display Length measurement and control 1.772 x 3.780 V13-T1-114 1 (45 x 96) Multiple models available: totalizers, Flow monitoring and control ratemeters, count controls, digital Process monitoring and display 1 panel meters and flow controls Voltage and current monitoring and display 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-113 Counters, Panel Meters, Tachometers and Timers 1.6 Flow Totalizers, Transmitters and Controls Eclipse Series 1 Product Description Features Standards and Certifications ● ● ● 1 Eaton’s Eclipse series flow Six- or 10-digit display 15-point linearization UL and cUL listed totalizer and controller can ● available ● 1/8 DIN size CE marked accept signals from analog ● Dual valve pre-warn 1 ● Red, LED display flow meters and display flow available ● 0.56 in (14 mm) high rates and volumes on a high- ● Optional analog, relay and 1 characters visibility LED. RS-485 outputs ● Scalable display ● NEMA 4X 1 ● Analog or pulse input ● Depluggable terminal versions blocks 1 ● Accessory power output 1 Eclipse Series Flow Totalizer and Control 1 1 1 1 1 Catalog Number Selection 1 Eclipse Flow Model 1 5775 X –4X X 1 1 Power Supply Output Option 1 0 = DC (9–30 Vdc) 0 = No option 1 = AC (85–265 Vac) 1 = Dual relays (standard or batch) 1 2 = Analog output (4–20 mA and 0–10V) 3 = Dual relays and analog output Input Option 4 = RS-485 communications 1 0 = Pulse input totalizer/ratemeter 5 = Dual relay and RS-485 1 = Pulse input batch control 6 = Analog output and RS-485 2 = Analog input totalizer/ratemeter 1 7 = Dual relays, analog output and RS-485 3 = Analog input batch control A = One relay, one transistor B = One relay, one transistor, analog output 1 C = One relay, one transistor, RS-485 D = One relay, one transistor, analog output and RS-485 1 Note 1 Output options 0, 2, 4 are not available for models -41X and -43X. 1 1 1 1 1 1 1 1 1 V13-T1-114 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.6 Flow Totalizers, Transmitters and Controls Product Selection 1 Eclipse Series Totalizer Display Preset Counters Eclipse Series 1 Totalizer Display Description Catalog Number Preset Counter Flow total rate, DC, pulse input 57750400 1 Flow total rate, DC, pulse input, dual relay out 57750401 1 Flow total rate, DC, pulse input, analog out 57750402 Flow total rate, DC, pulse input, dual relay out, analog out 57750403 1 Flow total rate, DC, pulse input RS-485 57750404 Flow batcher, DC, pulse input, dual relay out 57750411 1 Flow batcher, DC, pulse input, dual relay out, RS-485 57750415 Flow total/rate, DC, analog input 57750420 1 Flow total/rate, DC, analog input, dual relay out 57750421 1 Flow total/rate, DC, analog input, analog out 57750422 Flow total/rate, AC, pulse input 57751400 1 Flow total/rate, AC, pulse input, dual relay out 57751401 Flow total/rate, AC, pulse input, analog out 57751402 1 Flow total/rate, AC, pulse input, dual relay out, analog out 57751403 Flow total/rate, AC, pulse input, analog out 57751404 1 Flow batcher, AC, pulse input, dual relay out 57751411 1 Flow batcher, AC, pulse input, dual relay out, analog out 57751413 Flow batcher, AC, pulse input, dual relay out, RS-485 57751415 1 Flow total/rate, AC, analog input 57751420 Flow total/rate, AC, analog input, dual relay out 57751421 1 Flow total/rate, AC, analog input, analog out 57751422 Flow total/rate, AC, analog input, dual relay out, analog out 57751423 1 Flow total/rate, AC, analog input, analog out, RS-485 57751426 1 Flow batcher, AC, analog input, dual relay out 57751431 Flow total/rate, AC, pulse input, relay/transistor out 5775140A 1 Flow total/rate, AC, pulse input, relay/transistor out, analog out, RS-485 5775140D Flow total/rate, AC, analog input, relay/transistor out 5775142A 1 Flow total/rate, AC, analog input, relay/transistor out, analog 5775142D 1 Flow batcher, AC, analog input, relay/transistor out, analog 5775143D 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-115 Counters, Panel Meters, Tachometers and Timers 1.6 Flow Totalizers, Transmitters and Controls Technical Data and Specifications 1 General Specifications 1 Description Specification Input Power 1 AC powered models (57751-4XX) Input power 85–265 Vac, 47–63 Hz, 20 VA 1 External fuse 0.2A, 250 Vac, time delay (T200mA, 250V) 1 Isolation dielectric strength 2300 Vac DC powered models (57750-4XX) 1 Input power 9–30 Vdc, 12 VA External fuse 2.0A, 50 Vdc, time delay (T2A, 50V) 1 Reverse voltage protection Yes Isolation dielectric strength 2300 Vac to signal inputs and relays, 500 Vac to RS-485 and analog outputs 1 Human Interface 1 Display Six digits Type 0.56 in high, seven segment, red LED 1 Data Retention Memory type EEPROM, no batteries required 1 Duration 100 years Count Signal Input/Count Inhibit Signal Input 1 Sensor type Sink or source, DIP switch selectable 1 Input impedance 4.75k ohms to +5 Vdc or 34.9k ohms to ground Thresholds 1 High 3.5 to 28 Vdc Low 0 to 1.9 Vdc, for single ended signals 1 Magnetic pickup range 50 mV p-p to 65V rms into 34.9k ohms Slow response 50 Hz max. (DIP switch 2 and/or 5 ON) 1 Flat response 10 kHz 1 Flow Signal Input (Analog Input Models) Types 4–20 mA and 0–10 Vdc 1 Input impedance 100 ohms (current input), 1.27M ohms (voltage input) Overrange 50 mA max. (current input), 100V max. (voltage input) 1 Accuracy ±0.1% of reading, ±1 digit, and ±80 PPM/°C Control Inputs 1 Sensor type Sink only 1 Input impedance 4.75k ohms to +5 Vdc Thresholds 1 High 3.5 to 28 Vdc Low 0 to 1.0 Vdc 1 Response 25 ms maximum (5V signal) Accessory Power Output (Pulse Input Models) 1 Voltage 12 Vdc +10%/–13% 1 Current 75 mA max. Protection Short-circuit protected 1 Accessory Power Output (Analog Input Models) Voltage 24 Vdc ±10% 1 Current 90 mA max. Protection Short-circuit protected 1 1 1 V13-T1-116 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.6 Flow Totalizers, Transmitters and Controls General Specifications, continued 1 Description Specification Relay/Transistor Outputs (Standard on Batch Controls, Optional on Totalizers) 1 Number Two relays or one relay and one transistor Relay contact type One set Form C per relay 1 Relay contact rating 5A, 250 Vac or 30 Vdc 1 Transistor type NPN, opto isolated OFF state block 30 Vdc max., 0.1 mA max. leakage current 1 ON state conduct 50 mA max., 1.2 Vdc max. C-E drop Max. switching frequency 4 kHz (50-50 duty cycle) 1 Isolation dielectric strength 2300 Vac 1 Optional Outputs Analog retransmission 1 Output signals 4–20 mA (<750 ohms) and 0–10V (>2500 ohms) Accuracy 0.13% full scale and 100 PPM/°C (and 0.07% full scale change over 4–20 mA load ranges 1 Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and DC power inputs 1 RS-485 serial communications Baud rate 1200, 2400, 4800, 9600, or 19,200, programmable 1 Parity Even, odd or no parity Address range 00 to 99 decimal (00 indicates off line) 1 ® Protocol Opto 22 compatible Isolation dielectric strength 2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and 1 DC power inputs Environmental 1 Operating environment Indoor use to 2000 meters 1 Temperature Operating 32° to 122°F (0° to 50°C) 1 Storage –4° to 158°F (20° to 70°C) Humidity 0 to 85% RH, non-condensing 1 Vibration 2.5 Gs, 30 to 200 Hz Shock 30 Gs, 11 ms half sinewave 1 EMC Immunity to EN 50082-2 (heavy industrial) 1 Emissions to EN 50081-2 (heavy industrial) Front panel NEMA 4X when mounted with gasket provided 1 Agency approval CE EMC immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and pulse input/power lines. The shields were connected to earth ground at the Eclipse end of the shields. 1 Pollution degree 2 Overvoltage Category II 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-117 Counters, Panel Meters, Tachometers and Timers 1.6 Flow Totalizers, Transmitters and Controls Dimensions 1 Approximate Dimensions in Inches (mm) 1 Eclipse Flow Models 1 1 2.19 1.772 ±0.02 (55.6) PGM PGM 1 (45 ±0.6) View Edit Start Stop BATCH Enter Reset 1 4.04 1 (102.6) 3.622 ±0 .031 (92.00 ±0.8) 1 Panel Cutout 1 Max. Panel Thickness 0.190 (4.83) 1 1 3.63 (92.2) 1 3.31 1 (84.1) 0.27 1 (6.9) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-118 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.7 Fusion Integrated Machine Control Contents Fusion Integrated Machine Control 1 Description Page Fusion Integrated Machine Control 1 Standards and Certifications . . . . . . . . . . . . . . . V13-T1-120 Product Selection . . . . . . . . . . . . . . . . . . . . . . . V13-T1-120 1 Technical Data and Specifications . . . . . . . . . . . V13-T1-121 1 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-123 Learn 1 Online 1 1 1 1 1 1 Fusion Integrated Machine Control Product Description Features 1 ® ● The Fusion Integrated The Fusion has a multi-line User-configurable operator Machine Control has alphanumeric display which interface with back-lit LCD 1 advanced features, including can be programmed to show display and 18-button a five-preset high speed text messages, logic- tactile feedback keypad 1 counter with pre-warn, a generated prompts, alarms ● High speed counter with totalizer with preset, a batch and machine status. Up to five presets and pre-warn, 1 counter with preset and a eight screens can be shown totalizer, batch counter and ratemeter with high and low or optionally locked out. ratemeter setpoints. Unique to the Count and time presets can 1 ● 10 parameter sets count control world, the be made view-only or ● 13 digital inputs Fusion has five output relays editable. Preset entry is 1 ● (2) 4–20 mA inputs (rather than two), along with achieved with simple 0-9 ● two transistors and two keys on the front panel rather (2) 0–10V input 1 analog setpoint or follower than complicated scrolling ● (3) Form C, 2 Form A, outputs. Its ten available methods. The Fusion’s real 2 NPN transistor, (1) 4–20 1 parameter sets of pre-loaded time clock/calendar may be mA, and (1) 0–10V outputs values are useful as recipes, displayed and/or used to time ● RS-232 and RS-485 serial for job-stacking or for a and date stamp printouts. 1 communications variety of application-specific ● With its ladder logic, the 100-line ladder logic purposes. 1 Fusion is actually a 26 I/O processor for ultimate controller, making it a flexibility complete control for many 1 ● Configuration software machines and processes, included integrating the functions of ● 1 NEMA 4X enclosure external timers, pushbuttons, power supplies, indicating 1 lights, control relays and other components in the 1 same box. 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-119 Counters, Panel Meters, Tachometers and Timers 1.7 Fusion Integrated Machine Control Features and Benefits 1 Feature Customer Benefit High speed count functions; including scaling, main counter, “Canned” count functions offer flexibility and ease of setup in the desired units 1 five presets, pre-warn, totalizer, batch and rate of measure. High speed counting independent of ladder scan time Precise and repeatable output response for high performance applications. 1 Flexible display with selectable character sizes (large, medium, Minimizes confusion and operator errors as information can be tailored to what small), run screens and ladder triggered messages they need and in their language. Maintenance/management data can be 1 separated. Different character sizes allow optimization of information displayed. Machine status information can be displayed allowing operators to take action. 1 Simple front panel layout and keypad. Four soft keys and six Ease of use for operator. Numeric keypad allows for ease of preset and machine function keys can be used as inputs parameter entry. Function keys and soft keys allow easy and quick access to information and/or parameters needed by the operator and don’t require using 1 additional inputs. Eliminates cost associated with external pushbuttons and inputs. 1 Parameter sets Allows for predefined recipes/jobs to be preloaded for the operator. Simplifies operator interaction and minimizes errors. 1 Programmable relay logic Well understood programming method that allows flexibility in control functionality. Easy to tailor the control to various applications. 1 26 I/O (digital and analog) Provides application flexibility. Analog inputs allow monitoring key process parameters. Analog outputs allow interfacing to drives and other control products. 1 Integrated solution Reduced overall control costs, installation and commissioning. More flexible and capable than traditional count/control solutions but less complex than many 1 PLC solutions. ® Windows and front panel programming Ease of programming and configuration control. 1 ® RS-232 and RS-485 serial communication ports Allow for direct connection to PC for programming, connection to Modbus networks, interface to serial printer. 1 Robust type 4X package. DIN cutout and short depth Suited for wet applications. Same cutout as the President Series—easing the 2.82 in (71.6 mm) migration. Short depth minimizes the cost and size of the machine panel or control enclosure. 1 Input power: 85–265 Vac 50/60 Hz or 10–30 Vdc models Greatly reduces models required for different control voltages. 1 Output power: 12 Vdc at 75 mA, 24 Vdc at 100 mA Eliminates the need for an external power supply for encoders, analog transducers, etc. 1 Depluggable screw terminals Allows for ease of wiring and removal of control. Terminals are different sizes to error-proof installation. 1 Non-volatile memory and capacitor backed real time clock Don’t have to worry about a battery failing down the road. Real time clock Allows for control functions to be performed on day/time and allows for date/time stamping on printouts. 1 UL, cUL and CE marked Ease of meeting machine agency requirements and robust EMC performance. 1 1 Standards and Certifications ● UL and cUL listed 1 ● CE marked 1 1 1 Product Selection 1 Fusion Integrated Machine Control 57550400 1 Description Catalog Number Fusion integrated machine control—10–30 Vdc power 57550400 1 Fusion integrated machine control—85–265 Vac power 57551400 Fusion configuration software 57590400 1 1 1 V13-T1-120 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.7 Fusion Integrated Machine Control Technical Data and Specifications 1 General Specifications 1 Description Specification Environmental 1 Operation Indoor use to 2000m 1 Temperature 32° to 122°F (0° to 50°C) operating –4° to 158°F (–20° to 70°C) storage 1 Humidity 0 to 85% RH, non-condensing Vibration 2.5 Gs, 30–200 Hz 1 Shock 30 Gs, 11 ms half sinewave EMC EN61326:1997 1 All I/O lines except RS-485 <30m 1 Front panel Type 4X indoor use only, when mounted with gasket provided Safety UL and cUL listed, CE compliant 1 Input Power AC model 85–265 Vac, 47–63 Hz, 20 VA; isolation 2300 Vac 1 DC model 10–30 Vdc, 15 VA Inputs 1 Control 1 Number 10 Impedance 4.75k ohms to +5 Vdc 1 Thresholds High 3.5–30 Vdc 1 Low 0–1.0 Vdc Counter 1 Number Three (including reset) Impedance 4.75k ohms to +5 Vdc or 26.9k ohms to ground 1 Thresholds High 3.5–30V 1 Low 0–1.5V, or 200 mV p-p to 50V rms at 26.9k ohms (mag pickup) 1 Response 140 Hz or 14 kHz for sinking, push-pull or mag pickup inputs 60 Hz or 6 kHz for sourcing only inputs 1 All frequencies based on 50-50 duty cycle 6 kHz maximum sustained count speed 1 Analog Number 4 1 Type 4–20 mA and two 0–10 Vdc 1 Accuracy ±0.5% FS and ±200 PPM/°C Impedance 100 ohms (current input), 1.27M ohms (voltage input) 1 Overrange 45 mA max. (current input), 20V max. (voltage input) 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-121 Counters, Panel Meters, Tachometers and Timers 1.7 Fusion Integrated Machine Control General Specifications, continued 1 Description Specification Outputs 1 Power (AC input model only) 24 Vdc ±15%, 100 mA max., short-circuit protected 1 12 Vdc ±10%, 75 mA max., short-circuit protected Relays 1 Number 3 (Form C), 2 (Form A) Contacts 5A, 250 Vac, 30 Vdc 1 Isolation 2300 Vac Transistors 1 Number 2 Type NPN Darlington 1 Ratings 150 mA max. ON current, 30 Vdc max. OFF voltage 1 Analog Number 2, short-circuit protected 1 Type 4–20 mA (<450 ohms), 0–10V (>2500 ohms) Accuracy ±0.5% FS and ±200 PPM/°C 1 Common mode voltage rating 250 Vac Isolation 2300 Vac 1 RS-232 Connector DB-9S 1 Polarity DCE 1 Baud rate 1200–19200 RS-485 1 Connector Six-wire RJ-12 phonejack Baud rate 1200–19200 1 Data Retention Program data 1 Type Non-volatile Duration 100 years, no batteries 1 Real time clock Type Capacitor 1 Charge time Three minutes 1 Retention 1–5 days Human Interface 1 Display Type 128 x 64 pixel graphic LCD with LED backlight 1 Figure size 0.12 in (3 mm) high, 21 characters per line, 6 lines maximum 0.24 in (6 mm) high, 10 characters per line, 3 lines maximum 1 0.35 in (9 mm) high, 7 characters per line, 2 lines maximum 1 Keys Number 18 1 Type Membrane switches with tactile feedback Real time clock format Seconds, minutes, hours, day and date 1 1 1 1 1 1 V13-T1-122 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.7 Fusion Integrated Machine Control Dimensions 1 Approximate Dimensions in Inches (mm) 1 1 Fusion Integrated Machine Control 5.33 (135.5) 1 1 1 1 1 1 1 F1 F2 F3 1 1 1 1 F4 F5 F6 3.42 2.57 4 5 6 (86.9) (65.3) 1 123 5 1 1 6.18 (157) 2.50 (63.5) 0.38 2.79 (70.8) (9.7) 1 1 1 2.677±0.028 (68±0.7) 1 1 5.433±0.039 (138±1) 1 Note 1 1 Recommended panel cutout is 0.375 in (9.5 mm) max. panel thickness. 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-123 P/N 57551 400 123 45678910 11121314 15151617 xxxx 2 3 2 2 RUN L1 L2 01 Counters, Panel Meters, Tachometers and Timers 1.8 Special Function Controls Contents President Position Controller 1 Description Page President Position Controller 1 Technical Data and Specifications . . . . . . . . . . V13-T1-125 1 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-127 Learn 1 Online 1 1 1 1 1 1 1 President Position Controller Product Description Features Standards and Certifications 1 ● ● ● The 58868400 closed-loop 6-digit, LED display, 14 mm Manual or automatic UL Listed position control provides (0.56 in) high characters operation 1 digital output signals (run, ● ● 4 move registers plus Programmable offset, direction and fast/slow) to a home prewarn and kerf values 1 drive to cause a motor-driven ● ● 2 Form C relays and 5 NPN Backlash compensation tool to be positioned along a transistor outputs ● Programmable high/low 1 single axis. These signals can ● 28 kHz count speed limits also be used to control values ● ● 5 dwell time settings 20 mA current loop 1 in a hydraulic positioning ● communications system. Typically, a 15 Vdc at 100 mA power ● quadrature encoder, coupled output NEMA 4X front panel 1 to the drive mechanism, provides the feedback signal 1 to the position control. Up to five destinations can be 1 automatically sequenced through in a move-and-dwell process, or the operator can 1 select a single destination for move-and-stop positioning. 1 1 Product Selection 1 President Position Control 58868400 1 Description Catalog Number Single-axis position control 58868400 1 1 1 1 1 1 V13-T1-124 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.8 Special Function Controls Technical Data and Specifications 1 General Specifications 1 Description Specification Power Input 1 AC operation 120/240 Vac (±10%, –20%), 47 to 63 Hz 1 DC operation 11 to 16 Vdc (0.7A maximum) Power consumption 18 watts maximum 1 DC Power Output Output 15 Vdc (+1, –2), 100 mA maximum 1 Environment Operating temperature 32° to 130°F (0° to 55°C) 1 Storage temperature –40° to 160°F (–40° to 71°C) 1 Operating humidity 85% relative, non-condensing Rating NEMA 4 rating when mounted with gasket provided 1 Control Input Response START/STOP 1 mS 1 Go home input 5 mS Load position 5 mS 1 Reference input 1.7 mS 1 Input Voltage Count Inputs 1 High 10.5 to 24.5 Vdc Low 0 to 4.5 Vdc 1 Control Inputs High 3.8 to 15.0 Vdc 1 Low 0 to 1.2 Vdc Input Impedances 1 Count inputs 6.8k ohms to +15 Vdc (2.2 mA at 0 Vdc) 1 Control inputs 2.2k ohms to +5 Vdc (2.3 mA at 0 Vdc) Relay Outputs (2) 1 Type Form C contacts Load voltage Up to 240 Vac or 280 Vdc 1 Load current 5A resistive, 1.5A at 80% PF 1 Transistor Outputs (5) Type NPN open collector with surge protection 1 Load voltage 30 Vdc maximum Load current 300 mA maximum 1 Saturation 1.5V maximum at 300 mA Latency 150 +5 μS/1 kHz input speed ±10 μS 1 Communication 1 Type 20 mA loop (active transmit, passive receive) Speed 110, 300 or 1200 baud 1 Parity Odd, even, space Format 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit (110 baud uses 2 stop bits) 1 Load voltage 30 Vdc maximum Load current 300 mA maximum 1 Saturation 1.5V maximum at 300 mA 1 Latency 150 +5 μS/1 kHz input speed ±10 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-125 Counters, Panel Meters, Tachometers and Timers 1.8 Special Function Controls General Specifications, continued 1 Description Specification 1 Input Frequency 1 2 Quadrature selection 3 X1 1 High speed 28 kHz 1 Low speed 150 Hz 3 X2 1 High speed 14 kHz Low speed 150 Hz 1 3 X4 High speed 7 kHz 1 Low speed 150 Hz 1 Position Control Features Setpoints Four move setpoints plus one home setpoint 1 Range (all setpoints) –99999 to 999999 Decimal point Four positions, programmable 1 Dwell times Five, one for each setpoint 1 Dwell time range 00.01 to 99.98 seconds Scale factor range 0.00100 to 9.999999 1 Accuracy 100% when the position control is operated within the specified speeds and input voltages 1 Notes 1 Only function 60 and the double jumper affect the maximum input speed. The scale factor does not affect the input speed. 1 2 The maximum input frequency only on the selected quadrature operation. 3 Low speed jumper installed. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-126 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.8 Special Function Controls Dimensions 1 Approximate Dimensions in Inches (mm) 1 President Position Controller 5.80 5.38 1 (147.3) (137) 1 POSITION RUN 1234 5 6 7 8 9 101112131415161718 MOVE IN1 IN2 K1 K2 DWELL 1 MOVE HOME 2.62 + / - 3.04 1 2 3 4 5 FUNCTION DWELL (66.7) (77.2) 1 K1 K2 RECALL FAST JOG+ JOG- POSITION + NO C NO AC INPUTS NC C NO 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 START 6 7 8 9 0 ENTER STOP 1 1 5.91 Recommended Panel Cutout: 5.43 W x 2.68 H (137.9 x 68.1) (150) Gaskets 1 Pt. #28720-216 (Standard) Pt. #28720-217 Note: 1 gasket standard. 1 2nd gasket and Panel spacer optional. Use of optional 1 spacer and gasket Spacer reduces unit depth from 5.91 (150) 1 Counter to 5.38 (137.3). Front Panel mounting clip fits into four Spacer Kit Pt. #38820-400 1 Bezel square holes in side of counter. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-127 Counters, Panel Meters, Tachometers and Timers 1.9 Temperature Controls Contents TC Series 1 Description Page TC Series 1 Product Selection . . . . . . . . . . . . . . . . . . . . . . . V13-T1-129 1 Technical Data and Specifications . . . . . . . . . . . V13-T1-129 Special Control Function Inputs . . . . . . . . . . . . . . . V13-T1-130 1 1 1 1 1 1 1 1 TC Series Product Description Features and Benefits Standards and Certifications 1 ● ● ● Temperature controllers for a Universal temperature Fast sampling rate of up to UL recognized wide range of applications inputs allow user to select five times per second ● 1 CSA certified including heat treating, from PT100 or J, K, T, E, B, ensures accuracy in fast ● CE marked baking, packaging, furnace R, S, N, L thermocouples processes 1 ● RoHS compliant control, and chillers. without modification to the ● Standard IP65 front panel unit (TC48) provides protection 1 ● Advanced fuzzy modified in wash-down and other PID technology minimizes challenging environments 1 overshoot/undershoot and allows quick and accurate 1 responses 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-128 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.9 Temperature Controls Product Selection 1 TC Series TC24411100 1 Normally Description Stocked Item Catalog Number 1 Temperature control, 24 x 48 mm, two relay out, 90–250 Vac Yes TC24411100 Temperature control, 24 x 48 mm, SSR driver/relay out, 90–250 Vac Yes TC24412100 1 TC484120001 Temperature control, 48 x 48 mm, one relay out, relay alarm, 90–250 Vac Yes TC484110101 Temperature control, 48 x 48 mm, SSR driver out, 90–250 Vac Yes TC484120001 1 Temperature control, 48 x 48 mm, SSR driver out, relay alarm, 90–250 Vac Yes TC484120101 1 Temperature control, 48 x 48 mm, analog out, relay alarm, 90–250 Vac Yes TC484130101 Temperature control, 96 x 48 mm, one relay out, relay alarm, 90–250 Vac Yes TC964110100 1 Temperature control, 24 x 48 mm, two relay out, 11–26 Vac/Vdc — TC24511100 TC964110100 Temperature control, 48 x 48 mm, one relay out, relay alarm, 11–26 Vac/Vdc — TC485110101 1 Process control, 24 x 48 mm, analog/relay out, 90–250 Vac — PC24463100 1 Temperature control, 48 x 48 mm, analog out, relay alarm, 90–250 Vac — TC24413100 1 1 1 Technical Data and Specifications 1 General Specifications 1 Description Specification Power 1 Power 90–250 Vac, 47–63 Hz, 10 VA (TC24), 12 VA (TC48/TC96), 5W maximum (TCxx4) 11–26 Vac/Vdc, 10 VA (TC24), 12 VA (TC48/TC96), 5W maximum (TCxx5) 1 Input 1 Resolution 18 bits Sampling rate 5 times/second 1 Temperature effect ±1.5 μV/ºC for all inputs except mV input ±3.0 μV/ºC for mV input 1 Sensor lead resistance effect T/C 0.2 μV/ohm 1 Three-wire RTD 2.6ºC/ohm of resistance difference of 2 leads 1 Two-wire RTD 2.6ºC/ohm of resistance sum of 2 leads Burn-out current 200nA 1 Common mode rejection ratio (CMRR) 120dB Normal mode rejection ratio (NMRR) 55dB 1 Sensor break detection Sensor open for TC, RTD and mV inputs, sensor short for RTD input, below 1 mA for 4–20 mA, below 0.25V for 1–5V input 1 Sensor break response time Within 4 seconds for TC, RTD, and mV inputs; 0.1 second for 4–20 mA and 1–5V inputs Output 1 Relay rating 2A/240 Vac; 200,000 life cycles for resistive load 1 Pulsed voltage Source voltage 5V, current limiting resistance of 66 ohms Linear output 1 Resolution 15 bits Output regulation 0.02% for full load change 1 Output setting time 0.1 sec. (stable to 99.9%) Isolation breakdown voltage 1000 Vac 1 Temperature effect ±0.01% of SPAN/ºC 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-129 Counters, Panel Meters, Tachometers and Timers 1.9 Temperature Controls General Specifications, continued 1 Description Specification Alarm 1 Alarm relay Form C rating; 2A/240 Vac; 200,000 life cycles for resistive load 1 Alarm functions Dwell timer, deviation high/low alarm, deviation band high/low alarm, PV high/low alarm Alarm mode Normal, latching, hold, latching/hold 1 Dwell timer 0.1 to 4553.6 minutes Environmental and Physical 1 Operating temperature 14° to 122ºF (–10° to 50ºC) Storage temperature –40° to 140ºF (–40° to 60ºC) 1 Humidity 0–90% RH (non-condensing) 1 Altitude 2000m max. Pollution Degree 2 1 Insulation resistance 20M ohms min. (at 500 Vdc) Dielectric strength 2000 Vac, 50/60 Hz for 1 minute 1 2 Vibration resistance 10–55 Hz, 10 m/s for 1 minute Moldings Flame resistant polycarbonate 1 Dimensions TC96 = 1.88 in (48 mm) (W) x 3.77 in (96 mm) (H) x 3.15 in (80 mm) (D) 1 TC48 = 1.88 in (48 mm) (W) x 1.88 in (48 mm) (H) x 4.56 in (116 mm) (D) TC24 = 1.96 in (50 mm) (W) x 1.04 in (26.5 mm) (H) x 4.35 (110.5 mm) (D) 1 1 Special Control Function Inputs 1 Input Characteristics Type Range Accuracy at 25ºC Input Impedance 1 J –120º to 1000ºC (–184º to 1832ºF) ±2ºC 2.2M ohms K –200º to 1370ºC (–328º to 2498ºF) ±2ºC 2.2M ohms 1 T –250º to 400ºC (–418º to 752ºF) ±2ºC 2.2M ohms 1 E –100º to 900ºC (–148º to 1652ºF) ±2ºC 2.2M ohms B 0º to 1800ºC (32º to 3272ºF) ±2ºC (–200º to 1800ºC) 2.2M ohms 1 R 0º to 1767.8ºC (32º to 3214ºF) ±2ºC 2.2M ohms S 0º to 1767.8ºC (32º to 3214ºF) ±2ºC 2.2M ohms 1 N –250º to 1300ºC (–418º to 2372ºF) ±2ºC 2.2M ohms L –200º to 900ºC (–328º to 1652ºF) ±2ºC 2.2M ohms 1 PT100 (DIN) –210º to 700ºC (–346º to 1292ºF) ±0.4ºC 1.3k ohms 1 PT100 (JIS) –200º to 600ºC (–328º to 1112ºF) ±0.4ºC 1.3k ohms mV –8 mV to 70 mV ±0.05% 2.2M ohms 1 mA –3 mA to 27 mA ±0.05% 70.5 ohms V –1.3V to 11.5V ±0.05% 650k ohms 1 1 1 1 1 1 1 1 V13-T1-130 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Contents Accessories and Encoders 1 Description Page Accessories and Encoders 1 DIN Rail Adapter . . . . . . . . . . . . . . . . . . . . . . . . V13-T1-132 C-Face Ring Tachometer . . . . . . . . . . . . . . . . . . V13-T1-133 1 Magnetic Pickup Sensor and Gear . . . . . . . . . . V13-T1-134 1 Rotary Contactor—ES9513/ES9513RS . . . . . . . V13-T1-134 Measuring Wheels . . . . . . . . . . . . . . . . . . . . . . V13-T1-135 1 Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . V13-T1-135 Cube Style Shaft Encoders . . . . . . . . . . . . . . . . V13-T1-136 1 Heavy-Duty Shaft Encoders. . . . . . . . . . . . . . . . V13-T1-139 Right Angle, Size 20 Shaft Encoders. . . . . . . . . V13-T1-142 1 1 1 1 1 Accessories and Encoders Product Overview Features 1 ● Eaton offers a variety of Easy integration with Eaton accessories to complement counters 1 our counting and control product offering. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-131 Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders DIN Rail Adapter 1 Product Description Features ● ● 1 Allows mounting of 1/32 DIN For panel-mounting all DIN Construction— front panel mounted products size counters, timers and ● Mounting panel for to DIN rail inside panel. process indicators 0.94 x counter: Chrome-plated 1 1.89 in (24 x 48 mm) or sheet steel 1.97 x 0.98 in (50 x 25 mm) ● Top hat DIN rail adapter: 1 ● Cut-out: 0.98 x 1.97 in Glass fiber reinforced (25 x 50 mm) polymide 1 ● For snap-on fitting to 35 mm top hat DIN rails 1 1 Product Selection 1 DIN Rail Adapter A2448DINADAPT Description Catalog Number 1 DIN rail adapter for 1/32 DIN panel mount devices A2448DINADAPT 1 1 1 Dimensions 1 Approximate Dimensions in Inches (mm) 1 DIN Rail Adapter 3.98 (101.0) 1 1.77 1.98 (50.4) (45.0) 1 1 1.0 1.77 2.95 1 (25.4) (45.0) (75.0) 3.29 1 (83.5) 1 1 1 2.76 1 (70.0) 1 1 1 1 1 1 1 V13-T1-132 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders C-Face Ring Tachometer 1 Product Description Features ● ● Provides sensing of motor 5–16 Vdc input power Variety of motor C-face 1 speed when used with sizes: 56, 184, 254, 256 ● NPN transistor output, ratemeter/tachometer. ● 20 mA sinking capacity 39° to 225°F (4° to 107°C) 1 operating temperature ● 60 pulses per resolution ● 1 Zero speed pickup 1 Product Selection 1 C-Face Sensor 47007_ 1 Normally Description Stocked Item Catalog Number 1 Motor size 56C Yes 47007056 Motor size 143TC, 145TC, 182C, 184C Yes 47007184 1 Motor size 184TC, 213C, 215C, 254C Yes 47007215 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-133 Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Magnetic Pickup Sensor and Gear 1 Product Description Features 1 Sensor ideal for use with a Magnetic Pickup 30-Tooth Gear Accessory variety of Eaton counters to ● ● ● show motor/shaft speed or 0.25 in (6.4 mm) diameter Output is AC signal, 1.6 in (41 mm) diameter 1 amplitude proportional to measurement. ● ● Ideal for tachometer and 0.275 in (7 mm) bore speed of target rate control applications diameter 1 ● 10 ft (3m) cable attached ● ● –40° to 298°F (–40° to Mounting set screw ● 148°C) operating L-mounting bracket included 1 temperature included 1 Product Selection 1 Magnetic Pickup Sensor and Gear 47004400 and 28433400 1 Description Catalog Number Magnetic pickup 47004400 1 1 30-tooth gear for magnetic pickup 28433400 1 1 1 1 1 Rotary Contactor—ES9513/ES9513RS 1 Product Description Features ● ● Simple reed switch circuit to No power required 5/16 in (7.9 mm) double 1 provide a contact closure for ● shaft, 2400 rpm max. at Reed switch output counting. 1:1 ratio models for electronic 1 ● counters 12 in (304.8 mm) wire leads ● Contact closure output 1 ● Leaf switch output models for electromechanical 1 counters 1 Product Selection 1 Rotary Contactor 3910040 1 Description Rotary Contactor Catalog Number 12:1 ratio reed switch output ES9513RS 39100400 1 10:1 ratio reed switch output ES9513RS 39100401 1 1:1 ratio reed switch output ES9513RS 41100400 1:3 ratio reed switch output ES9513RS 41100401 1 1:3.28 ratio reed switch output ES9513RS 41100402 1:10 ratio reed switch output ES9513RS 41100403 1 1:10 ratio leaf switch output ES9513 40892400 1:1 ratio leaf switch output ES9513 40891400 1 1:3 ratio leaf switch output ES9513 40892401 1 1 V13-T1-134 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Measuring Wheels 1 Product Description Features ● ● Measuring wheel mounts to For use with shaft Urethane, rubber and 1 Eaton encoders and rotary encoders and rotary knurled edges available contactor to allow for contactors 1 accurate measurement. ● 12 in (304.8 mm) meter circumference 1 1 Product Selection 1 1 Ft Circumference Measuring Wheels Measuring Wheel Normally 1 Description Stocked Item Catalog Number 5/16 in bore, urethane rim Yes 20144300KIT 1 3/8 in bore, urethane rim — 20144303KIT 1 5/16 in bore, rubber rim Yes 20154300KIT 3/8 in bore, rubber rim Yes 20154301KIT 1 5/16 in bore, knurled rim Yes 20156300KIT 3/8 in bore, knurled rim — 20156301 1 1 1 1 Mounting Bracket Product Description 1 Mounting bracket for Eaton D-Series counters and rotary 1 contactors. 1 Product Selection 1 Mounting Bracket Mounting Bracket 1 Normally Description Stocked Item Catalog Number 1 Mounting bracket Yes 40460400 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-135 Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Cube Style Shaft Encoders 1 Product Description Features ● ● 1 Provides accurate pulse 5–28 Vdc input power Up to 600 pulses per outputs for use with PLCs ● revolution 80 mA current draw and counters. ● 3/8 in (9.5 mm) double 1 ● NPN transistor output, ended shaft 250 mA sinking capacity ● ABEC three double sealed 1 ● Square wave output; ball bearings (50-50 duty cycle) ● Tapped holes for face or ● 1 Single channel and base mounting quadrature models ● Military style connector 1 1 Product Selection 1 Cube Shaft Encoders Cube Shaft Encoder 1 Normally Description Stocked Item Catalog Number Single Channel 1 60 pulses per revolution — 38150060 1 100 pulses per revolution Yes 38150100 120 pulses per revolution — 38150120 1 600 pulses per revolution Yes 38150600 Quadrature 1 60 pulses per revolution — 38151060 1 100 pulses per revolution Yes 38151100 120 pulses per revolution — 38151120 1 600 pulses per revolution Yes 38151600 1 Accessory 1 1 Mounting Bracket Mounting Bracket 1 Normally Description Stocked Item Catalog Number 1 Mounting bracket — 40460402 1 Note 1 40460400 is shown, 40460402 has additional mounting plate for encoders. 1 1 1 1 1 1 1 1 1 1 V13-T1-136 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Technical Data and Specifications 1 General Specifications 1 Description Specification Electrical 1 Input (38150) Voltage 9 to 16 Vdc 1 Current 60 mA max. at 16 Vdc 1 Ripple 2% Input (38151) 1 Voltage 5 to 28 Vdc Current 60 mA nom., 100 mA max. 1 < Ripple 2% Output 1 Type Current sinking transistor with 1.5k ohms pull-up Sinking current 100 mA max. 1 Max. voltage at 100 mA 1.3 Vdc 1 Blocking voltage 40 Vdc max. Polarity Positive 1 Wave shape Square wave Pulse rate 1 38150 1 to 20,000 pulse per second 38151 1 to 10,000 pulse per second 1 Rise time <1 μS 1 Pulses per rev. 1 to 1270 Accuracy Within ±0.1° 1 Environmental Operating temperature 32° to 167°F (0° to 75°C) 1 Vibration 3 Gs at 5 to 1000 cps Shock 20 Gs, 10 ms 1 Mechanical 1 Shaft speed 6000 RPM max. Shaft rotation CW or CCW 1 Bearings Sealed ball bearings Starting torque 0.1 oz-in 1 2 Moment of inertia 0.0025 ounce in-sec Radial loading 40 pounds operating 1 Axial loading 30 pounds operating 1 Shaft 3/8 in (9.5 mm) dia. Operating life Up to 100,000 hours, depending on speed 1 Housing Aluminum with black anodized finish. Sealed against dust, oil, vapor and moisture. Mounting Bottom or front face 1 Weight 1 lb (0.5 kg) max. 1 Connector MS-3102E-14S-6P Mating connector MS-3106A-14S-6S with 10 ft (3m) shielded cable and termination for electronic controls 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-137 Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Dimensions 1 Approximate Dimensions in Inches (mm) 1 Cube Shaft Encoders 2.25 0.50 0.25 1 (57.2) (12.7) (6.4) 0.06 0.70 1 (1.6) (17.8) 0.33 1 (8.3) 2.25 1 (57.2) 1 45° 0.38 (9.5) 1 2.25 (4) 6.32 (160.5) Tapped Holes (4) 6.32 (160.5) Tapped Holes (57.2) 0.25 (6.4) Deep on 2.00 (50.8) B.C. 0.25 (6.4) Deep on 2.00 (50.8) B.C. (Same Mtg. Holes on 1 Opposite End and Bottom) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-138 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Heavy-Duty Shaft Encoders 1 Product Description Features ● ● Provides accurate pulse 5–28 Vdc input power 3/8 in (9.5 mm) single 1 outputs for use with PLCs ended shaft ● 80 mA current draw and counters. ● ● ABEC 3 double sealed ball 1 NPN transistor output, bearings 250 mA sinking capacity ● ● Tapped holes for face or 1 Square wave output base mounting ● Single channel and ● Military style connector quadrature models 1 1 Product Selection 1 Heavy-Duty Encoder Heavy-Duty Shaft Encoder 1 Normally Description Stocked Item Catalog Number 1 Single Channel 60 pulses per revolution Yes 48370060 1 100 pulses per revolution — 48370100 120 pulses per revolution Yes 48370120 1 600 pulses per revolution Yes 48370600 Quadrature 1 60 pulses per revolution Yes 48371060 1 100 pulses per revolution Yes 48371100 100 pulses per revolution Yes 48371120 1 600 pulses per revolution Yes 48371600 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-139 Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Technical Data and Specifications 1 General Specifications 1 Description Specification Electrical 1 Input Voltage 5 to 28 Vdc 1 Current 60 mA nom., 100 mA max. 1 Ripple –2% Output 1 Type Current sinking transistor with 1.5k ohms pull-up Sinking current 100 mA max. 1 Max. voltage at 100 mA 1.3 Vdc Blocking voltage 40 Vdc max. 1 Polarity Positive 1 Wave shape Square wave (50-50 duty) Pulse rate 0 to 20,000 pulse per second 1 Rise time <1 μS Pulses per rev. 1 to 1270 1 Accuracy Within ± 0.1° or 6 arc minutes Environmental 1 Operating temperature 32° to 167°F (0° to 75°C) 1 Vibration 3 Gs at 58 to 500 cps Shock 50 Gs, 11 ms duration 1 Mechanical Shaft speed 6000 RPM max. 1 Shaft rotation CW or CCW 1 Bearings Sealed ball bearings Starting torque 1.0 oz-in 1 Radial loading 50 pounds operating Axial loading 35 pounds operating 1 Shaft 3/8 in (9.5 mm) dia. Housing Aluminum with black painted finish. Sealed against dust, oil, vapor and moisture. 1 Mounting Provisions for bottom or front face 1 Weight 3.25 lbs (1.47 kg) max. Connector MS-3102E-14S-6P 1 Mating connector MS-3106A-14S-6S with 10 ft (3m) shielded cable and termination for electronic controls (Part No. 29665-300) 1 Connector, clamp and bushing only (Part No. 29729-300) 1 1 1 1 1 1 1 1 V13-T1-140 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Dimensions 1 Approximate Dimensions in Inches (mm) 1 Heavy-Duty Encoder 3.00 1 (76.2) 0.70 0.81 3.00 (17.8) 1.50 (20.6) (76.2) 1 (38.1) 1.13 0.06 1.50 (28.6) (1.6) (38.1) 1 1.18 1.50 (30.0) (38.1) 1 3.00 (76.2) 1 1.50 45° (38.1) Dia. 0.38 (9.5) 1 Shaft 6.00 with Flat Mounting Holes (Typical) 2.00 (50.8) Bolt Hole Circle (152.4) 1/4-20, 0.55 (14.0) Deep 1 on 2.00 (50.8) B.C. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-141 Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Right Angle, Size 20 Shaft Encoders 1 Product Description Features ● ● 1 Provides accurate pulse 5–28 Vdc input power Flange mounting outputs for use with PLCs ● ● 100 mA current draw 3/8 in (9.5 mm) shaft and counters. diameter 1 ● NPN transistor output, ● 100 mA sinking capacity Double shielded ball bearings 1 ● Quadrature output, two ● square waves Military style connector ● 1 Up to 1800 pulses per revolution 1 Product Selection 1 Right-Angle Shaft Encoder, Size 20 1 38159_ Description Catalog Number 1 100 pulses per revolution 38159100 120 pulses per revolution 38159120 1 600 pulses per revolution 38159600 1000 pulses per revolution 381591000 1 1800 pulses per revolution 381591800 1 1 Encoder Cables Description Catalog Number 1 10 ft encoder cable 29665300 1 15 ft encoder cable 29665315 20 ft encoder cable 29665320 1 25 ft encoder cable 29665325 30 ft encoder cable 29665330 1 35 ft encoder cable 29665335 40 ft encoder cable 29665340 1 50 ft encoder cable 29665350 1 75 ft encoder cable 29665375 100 ft encoder cable 29665400 1 1 1 1 1 1 1 1 1 1 1 V13-T1-142 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Technical Data and Specifications 1 General Specifications 1 Description Specification Electrical 1 Input Voltage 5 to 28 Vdc (4.75 min., 28.0 max.) 1 Current 100 mA max. with no output load 1 Ripple –2% peak to peak at 5 Vdc Output 1 Type Quadrature current sinking transistors with 2.2k ohms pull-up Sinking current 100 mA max. 1 Max. voltage at 100 mA 1.3 Vdc Blocking voltage 40 Vdc max. 1 Polarity Positive 1 Wave shape Square wave (50-50 duty cycle) Pulse rate 0 to 100,000 pulses per second 1 Noise immunity Tested to BS EN6100-4-2; IEC801-3; BS EN61000-4-4; DDENV 50141; DDENV 50204; BS EN55022 (with European compliance option) 1 Symmetry 180 electrical degrees ±18 Quadrature phasing 90 electrical degrees ±36 1 Minimum edge separation 54 electrical degrees Rise time <1 μS 1 Pulses per rev. 1 to 1270 1 Accuracy Within ±0.1° Environmental 1 Operating temperature 32° to 158°F (0° to 70°C) Vibration 20 Gs at 50 to 500 cps 1 Shock 75 Gs, 11 ms Mechanical 1 Shaft speed 8000 RPM max. 1 Shaft rotation CW or CCW Bearings Double shielded ball bearings 1 Starting torque 1.0 oz-in typical 4 2 Moment of inertia 5.2 x 10 ounce in-sec 1 9 Radial and axial loading (80 lbs max.) 20–40 lbs for bearing life of 1.5 x 10 revolutions 5 2 Maximum acceleration 1 x 10 radians/second 1 Shaft 0.375 in (9.5 mm) dia. 1 Housing Black non-corrosive finish. Sealed against dust, oil, vapor and moisture. Mounting Flange mount 1 Weight 11 oz (312g) Connector MS-3102E-14S-6P 1 Mating connector MS-3106A-14S-6S with 10 ft (3m) shielded cable and termination for electronic controls (Part No. 29665-300) 1 Connector, clamp and bushing only (Part No. 29729-300) 1 1 1 1 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-143 Counters, Panel Meters, Tachometers and Timers 1.10 Accessories and Encoders Dimensions 1 Approximate Dimensions in Inches (mm) 1 Right-Angle Shaft Encoder 6-32 UNC Side Mount 1 Shaft Size 0.25 (6.4) Deep 4 x 90° MS Style Dia. 2.0 (50.8) B.C. 3/8" 0.3745 (9.512) Connector 0.87 1 (22.1) 0.75 0.80 (19.1) 1 (20.3) 0.63 (15.9) 1 2.0 2.06 1.75 1.18 (50.8) 0.05 (52.3) (44.5) (30) 1 0.05 (1.3) (1.3) 1 0.60 Dia. 0.16 (4.0) (15.2) 0.30 Through 4 x 90° 1.41 1 (7.6) Dia. 2.48 (62.9) B.C. 2.0 (35.9) (50.8) 2.06 1 (52.3) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V13-T1-144 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com Counters, Panel Meters, Tachometers and Timers 1.11 Accessories Spare Parts 1 Style Number Description 36172202KIT Front panel gasket 1 48369200KIT Mounting clip 28748200KIT Screw for mounting clip 1 48355110KIT Terminal strip—10 position 1 48355112KIT Terminal strip—12 position 58802420 Desk kit for President Series (part numbers 5882–5886 and 5782) 1 29729300 Accessories connector 56460400 Sequence control 1 57044200KIT 6460 keypad 57740290KIT Mounting clip 1 46066220KIT Gasket 48720623KIT Ambassador front keypad 1 28720400KIT Kit mounting Ambassador Series 1 48720614KIT Label position control 48720280KIT Label membrane switch, Ambassador 1 General Accessories 1 Style Number Description 48160400 Input signal conditioner 1 48160440 Timer module (selectable time base oscillator) 1 48160451 Analog to frequency converter 499904xx(08/16) Simultaneous input processor (anti-coincidence counting from multiple input devices) 8 inputs/16 inputs 1 38091400 RC surge suppressor 3605945x(0/1) Solid-state I/O modules (AC input and output, DC input and output) 0 = DC, 1= AC 1 36059201 Plug-in-module, 10–32 Vdc or 15–32 Vac input 36059202 Plug-in-module, 12–140 Vac output 1 Fusion 1 Style Number Description 1 47590200 Front overlay label 1 Ambassador Family Accessories Style Number Description 1 48183401 Desk mount kit (enclosure for flat surface mounting) 58801460 RS-485 to RS-232 communications converter 1 58801461 RS-485 to RS-232 communications converter (Europe) 38145400 RS-485 interconnect kit 1 1 38146xxxx RS-485 cable—xxxx is length in feet, specify with 4 digits (0500 = 500 ft) 1 President 1 Style Number Description 28720302KIT Mounting kit 1 28720301KIT Kit mounting clip and gasket 48720410 5881-0 President replace label 1 48720420 Label kit 1 48720430 Kit label replace Lexan to Mylar 48720440 5884 President replace label 1 48720450 5885 President replace label 48720460 5886 President replace label 1 Note 1 Call EatonCare. 1 Volume 13—Counters, Timers and Tachometers CA08100015E—January 2013 www.eaton.com V13-T1-145

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 5-H-1-1-R have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Durant 57601-402 Ambassador Series Single Preset Count Control with Batch Rate Totalizer, 115 VAC

product

Durant 5770 Eclipse Series Digital Panel Meters

product

Durant 58801-400 RS-232-C 25 Pin Female Connector Communications Module

product

Durant 58801-430 totalizer Star Network Controller

product

Durant 5882-1 Digital Counter

product

Counter, Supply Voltage 115/230 Volts, Counts per Second 7500, Number of Digits 6, Mount Style Panel...