DURANT 5770
Datasheet
Extracted Text
Counters, Panel Meters, Tachometers and Timers 54-60 Digital Panel Meters June 2008 ® Eclipse Series — Durant Data Retention❑Accuracy: ±0.5% of reading, ±0.13% FS, ±0.5 digit, and ±200 ■Memory Type: EEPROM, no batter- PPM/°C for crest factor = 1; plus ies required ±0.7% for crest factor = 1 to 3; and ■Duration: 100 years ±2.5% for crest factor = 5 Signal Input ■5A AC Models (5770X-44X) — ■DC Voltage Models (5770X-40X) — ❑Range: 5A AC, true RMS ❑Range: ±199.9 mV DC, ±1.999V ❑Frequency: 40 to 1000 Hz Cat. No. 57700400 DC, ±19.99V DC, ±199.9V DC, DIP ❑Impedance: 0.02 ohms (shunt out- Switch Selectable put capacitive coupled) ❑Impedance: 1 M Ω (ohms) Features ❑Overrange: 10A Maximum ❑Overrange: 750V DC/530V AC ■4 Full digits❑Accuracy: ±0.4% of reading, except 220V DC/AC on 199.9 mV ±0.13% FS, ±0.5 digit, and ±200 ■1/8 DIN Size range PPM/°C for crest factor = 1; plus ■Red, LED display❑Accuracy: ±0.1% of reading, ±0.7% for crest factor = 1 to 3; and ±0.03% FS, ±0.5 digit, and ±80 ■0.56" (14 mm) high characters ±2.5% for crest factor = 5 PPM/°C ■Scalable display ■Process Models (5770X-45X) — ■Flashing alarms■AC Voltage Models (5770X-41X) — ❑Range: 4 – 20 mA DC, 0 – 10V DC, ■Maximum/minimum data hold❑Range: 199.9 mV AC, 1.999V AC, 1 – 5V DC; separate input 19.99V AC, 199.9V AC, DIP Switch ■Optional analog, relay and RS-485 terminals for voltage and current Selectable, all ranges true RMS outputs signals ■NEMA 4X❑Frequency: 40 to 1000 Hz ❑Impedance: 100 Ω (current input) ■Depluggable terminal blocks❑Impedance: 1 M Ω (capacity and 1.27 M Ω (voltage input) coupled) ❑Overrange: 50 mA maximum (cur- ❑Overrange: 750V DC/530V AC Standards and CertiŢcations rent input) and 100V maximum except 220V DC/AC on 199.9 mV (voltage input) ■UL and cUL Listed, CE Marked range ❑Power Output: 24V DC ±10%, 90 ❑Accuracy: ±0.5% of reading, mA max, short circuit protected ±0.13% FS, ±0.5 digit, ±180 PPM/ Technical Data and ❑Accuracy: ±0.1% of reading, °C for crest factor = 1; plus ±0.7% ±0.03% FS, ±0.5 digit, and ±80 SpeciŢcations for crest factor = 1 to 3; and ±2.5% PPM/°C for crest factor = 5 Input Power Optional Outputs ■DC Current Models (5770X-42X) —■AC Powered Models (57751-4XX) ■Relay Board — ❑Range: ±199.9 µA DC, ±1.999 mA ❑Input Power: 85 – 265V AC, ❑Dual relay: 1 set of form C DC, ±19.99 mA DC, ±199.9 mA DC, 47 – 63 Hz, 20 VA contacts each DIP Switch Selectable ❑External Fuse: 0.2A, 250V AC, ❑Contact rating; 5A, 250V AC or ❑Impedance: 199.9 mV/selected Time Delay (T200mA, 250V) 30V DC range ❑Isolation Dielectric Strength: ❑Isolation dielectric strength: ❑Overrange: 30 mA (1 99.9 µA 2300V AC 2300V AC range), 100 mA (1. 999 mA range), ■DC Powered Models (57750-4XX) 300 mA (19.99 mA range), 1 A ■Analog Retransmission — ❑Input Power: 9-30V DC, 12 VA (199.9 mA range) ❑Output Signals: 4 – 20 mA ❑External Fuse: 2.0A, 50V DC, Time ❑Accuracy: ±0.1% of reading, (<750 Ω) and 0 – 10V (>2500 Ω) Delay (T2A, 50V) ±0.03% FS, ±0.5 digit, and ±120 ❑Accuracy: 0.13% FS, 100 PPM/°C, PPM/°C ❑Reverse Voltage Protection: Yes 0.07% FS change with 4 – 20 mA ■AC Current Models (5770X-43X) load, ±0.3% FS for 4 – 20 mA ❑Isolation Dielectric Strength: output, only after exposure to ❑Range: 199.9 µA AC, 1.999 mA 2300V AC to signal inputs and 85% relative humidity AC, 19.99 mA AC, 199.9 mA AC, relays, 500V AC to RS-485 and 54 DIP Switch Selectable, all ranges analog outputs❑Isolation dielectric strength: true RMS 2300V AC to signal inputs, relays Human Interface and AC power input; 500V AC to ❑Frequency: 40 to 1000 Hz ■Display: ±4 full digits RS-485 and DC power inputs ❑Impedance: 199.9 mV/selected ■Type: 0.56" (14 mm) high, seven range (shunt output capacitive segment, red LED coupled) ■Update Time: 0.4 seconds ❑Overrange: 30 mA (11 99.9 µA ■Alarm: Flashing display range), 100 mA (1.999 mA range), ■Indicator: One red LED program/ 300 mA (19.99 mA range), 1A calibration indicator with max./min. (199.9 mA range) capture and hold For more information visit: www.eaton.com CA08102001E Counters, Panel Meters, Tachometers and Timers 54-61 Digital Panel Meters June 2008 ® Eclipse Series — Durant ■RS-485 Serial Communication — Catalog Number Selection ❑Baud Rate: 1200, 2400, 4800, 9600 Table 54-62. Eclipse Series Digital Panel Meters Numbering System or 19,200, programmable ❑Parity: Even, odd or no parity 5770 X - 4X X❑Address Range: 00 to 99 decimal ®❑Protocol: Opto 22 compatible � Power Supply Output Option ❑Isolation Dielectric Strength: 2300V AC to signal inputs, relays, 0 = DC (9 – 30V DC) 0 = No Option 1 = AC (85 – 265V AC) 1 = Dual Relay and AC power input; 500V AC to 2 = Analog Output (4 – 20 mA analog outputs and DC power and 0 – 10V) inputs Input Option 3 = Dual Relay, Analog Output (4 – 20 mA and 0 – 10V) 0 = DC Volt Environmental 4 = RS-485 Communications 1 = AC Volt TRMS ■Operating Env.: Indoor use to 2000 5 = Dual Relay, RS-485 2 = DC Amp 6 = Analog, RS-485 (4 – 20 mA meters 3 = AC Amp TRMS and 0 – 10V) 4 = 5A AC TRMS■Temperature — 7 = Dual Relay, Analog, RS-485 5 = Process (4 – 20 mA, ❑Operating: 32 to 122°F (0 to 50°C) (4 – 20 mA and 0 – 10V) 0 – 10V, 1 – 5V) 6 = Temperature (J, K, T,❑Storage: -4 to 158°F (-20 to 70°C) PT100 RTD) ■Humidity: 0 to 85% RH, non- condensing � Output Options 0, 2, 4 are not available for models -41X and -43X. ■Vibration: 2.5 Gs, 30 to 200 Hz ■Shock: 30 Gs, 11 mS half sinewave ■EMC/EMI: Per EN 61326-1 Industrial ■Front Panel: NEMA 4X when mounted with gasket provided ■Agency Approval: ❑CE EMC immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and signal input lines. The shields were connected to earth ground at the Eclipse end of the shields. ❑Conducted emissions requirements were met assuming that the AC signal input would not be connected directly to the AC Mains. ❑The measurement error during RF immunity testing was less than ±5% of full scale. In addition, models with an AC signal input had measurement error of less than +25% of full scale during RF immunity testing of the RS-485 at frequencies below 1 MHz. ■Pollution Deg. 2: Overvoltage Category II 54 CA08102001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers 54-62 Digital Panel Meters June 2008 ® Eclipse Series — Durant Dimensions ® Durant 2.19 1.772 ±0.02 (55.6) (45 ±0.6) PGM 4.04 (102.6) 3.622 ±0 .031 (92.0 ±0.8) Panel Cutout Max. Panel Thickness 0.19 (4.8) 3.63 (92.2) 3.31 (84.1) 0.27 (6.9) Figure 54-55. Eclipse Series Digital Panel Meters — Approximate Dimensions in Inches (mm) 54 For more information visit: www.eaton.com CA08102001E
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the 5770 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods