COSEL UAW250S-24
Datasheet
Extracted Text
Ordering information Unit type UA W 250 S -5 -O UAW250S 123456 1Series name R 2Autoranging input 3Output wattage UAW 4Single output 5Output voltage 6Optional C :with Coating G :Low leakage current N :with Cover R :with Remote ON/OFF Please refer to derating curve, because the rated load current depends on cooling method that is convention cooling or forced air. MODEL UAW250S-3 UAW250S-5 UAW250S-12 UAW250S-24 UAW250S-48 MAX OUTPUT WATTAGE[W] 150 250 258 264 249.6 DC OUTPUT 3V 50A 5V 50A 12V 21.5A 24V 11A 48V 5.2A SPECIFICATIONS MODEL UAW250S-3 UAW250S-5 UAW250S-12 UAW250S-24 UAW250S-48 ( ) VOLTAGE[V] AC85 - 132 / 170 - 264 1 Auto-selectable f ( ) ACIN 100V 6typ Io=100% CURRENT[A] ( ) ACIN 200V 3typ Io=100% ( ) FREQUENCY[Hz] 50/60 47-63 INPUT EFFICIENCY[%] 70typ 77typ 80typ 83typ 83typ ( )( ) ACIN 100V 15/40typ Io=100% Primary Surge Current/Secondary Surge Current INRUSH CURRENT[A] ( )( ) ACIN 200V 30/40typ Io=100% Primary Surge Current/Secondary Surge Current LEAKAGE CURRENT[mA] 0.75max (60Hz, According to UL, CSA and VDE) VOLTAGE[V] 3 5 122448 CURRENT[A] 50 50 21.5 11 5.2 LINE REGULATION[mV] 40max 40max 80max 100max 192max LOAD REGULATION[mV] 80max 80max 120max 160max 300max *1 0to+50 80max 80max 120max 120max 150max C RIPPLE[mVp-p] 1 -10-0 * 120max 120max 150max 150max 200max C *1 OUTPUT 0to+50 120max 120max 150max 150max 350max C RIPPLE NOISE[mVp-p] *1 -10-0 180max 180max 200max 200max 400max C TEMPERATURE REGULATION[mV] 40max 50max 120max 240max 480max *2 DRIFT[mV] 12max 20max 48max 96max 192max ( , ) START-UP TIME[ms] 800max ACIN 85/170V Io=100% HOLD-UP TIME[ms] 10typ (ACIN 85/170V, Io=100%) 20typ (ACIN 100/200V, Io=100%) , OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6 +10% -5% OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically PROTECTION OVERVOLTAGE PROTECTION 4.00 - 5.25V Works at 115 - 140% of rating CIRCUIT AND ( ) OPERATING INDICATION LED Green OTHERS REMOTE SENSING Provided INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 25mA, DC500V 50M min (At Room Temperature) W , , , ( ) ISOLATION INPUT-FG AC2 000V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature W , , ( ) OUTPUT-FG AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature W OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +55 , 10 - 90%RH (Non condensing)(Refer to DERATING CURVE), 3,000m (10,000feet) max C , , ( ), , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 10 - 90%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis SAFETY AND , , , AGENCY APPROVALS UL1950 CSA C22.2 No.234 EN60950 VDE0160 Complies with IEC950 NOISE , , , CONDUCTED NOISE Complies with FCC-B CISPR22-B EN55022-B VCCI-B REGULATIONS CASE SIZE/WEIGHT 95 35 278mm (without terminal block)(W H D) /1.1kg max (without cover) X X X X OTHERS COOLING METHOD Convection/Forced air *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN:RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. A-92
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the UAW250S-24 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods