COSEL AD480-30
Specifications
Notes
30V10 (peak 24)A Forced Air
Datasheet
Extracted Text
Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com Ordering information Unit type AD 240 -24 -O AD240 1234 1Series name 2Output wattage 3Output voltage 4Optional AD C :with Coating G :Low leakage current P :Parallel operation R :with Remote ON/OFF MODEL AD240-24 AD240-30 MAX OUTPUT WATTAGE[W] 240 240 DC OUTPUT 24V 10A 30V 8A SPECIFICATIONS MODEL AD240-24 AD240-30 ( ) VOLTAGE[V] AC85 - 132 / 170 - 264 1 User-selectable f FREQUENCY[Hz] 47 - 440 EFFICIENCY[%] 85typ 85typ INPUT ( ) ACIN 100V 15max Io=100% INRUSH CURRENT[A] ACIN 200V 30max (Io=100%) ( , ) LEAKAGE CURRENT[mA] 1.0max 60Hz According to DEN-AN VOLTAGE[V] 24 30 CURRENT[A] 10 8 LINE REGULATION[mV] 300max 260max LOAD REGULATION[mV] 300max 420max 1 RIPPLE[mVp-p] 0to+45 * 240max 240max C *1 OUTPUT RIPPLE NOISE[mVp-p] 0to+45 480max 480max C TEMPERATURE REGULATION[mV] 0to+45 500max 600max C 2 DRIFT[mV] * 500max 120max OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.6 - 26.4 28.5 - 33.0 ( , ) START-UP TIME[ms] 500max ACIN 100/200V Io=100% HOLD-UP TIME[ms] 15typ (ACIN 100/200V, Io=100%) PROTECTION OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically CIRCUIT , , , ( ) INPUT-OUTPUT AC1 500V 1minute Cutoff current = 10mA DC500V 100M min At Room Temperature W ISOLATION INPUT-FG AC1,500V 1minute, Cutoff current = 10mA, DC500V 100M min (At Room Temperature) W , , ( ) OUTPUT-FG AC500V 1minute Cutoff current = 50mA DC500V 100M min At Room Temperature W , , ( )( ), , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE 0to+60 20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max C STORAGE TEMP.,HUMID.AND ALTITUDE -25 to +80 , 10 - 95%RH (Non condensing), 9,000m (30,000feet) max C ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 30minutes each along X Y and Z axis 2 ( ), , , IMPACT 98.0m/s 10G 20ms once each X Y and Z axis CASE SIZE/WEIGHT 75 99 220mm (W H D) /1.8kg max X X X X OTHERS COOLING METHOD Convection *1 Measured by 15MHz oscilloscope. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. A-136 Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com AD240 External view max 75 20 200 +0.5 +0.5 12.5 12.5 50 50 - - Voltage Adjust (23) AD LM AD240 +V -V FG VS1 VS2 AC1 100/200 AC2 4-M3 M4 4-M3 Mounting Hole Mounting Hole ¶2 3-M3 ¶1 Mounting Hole ¶2 Safety Cover + 0.5 - +0.5 20 175 - ¶Mounting torque ¶1: 0.6N•m(6.3kgf•cm)max ¶Weight : 1.8kg or less ¶2: 0.4N•m(5.0kgf•cm)max ¶Tolerance : t1 ¶Dimensions in mm. Performance data STATIC CHARACTERISTICS RISE TIME & FALL TIME ¡ ¡ 24 Output Voltage 22 900 20 700 18 Io=100% Io=50% 16 AC100V Io=100% 14 500 12 DC Output 10 300 AC Input 8 ACIN 100V Ripple 100 0 40 50 60 70 80 90 100 110 120 130 140 50ms/DIV 60Hz INPUT VOLTAGE V ( AC 100V ) ¡OVERCURRENT CHARACTERISTICS ¡DERATING CURVE 26 24 22 20 qConvection 3 wForced Air(0.5m /min) 18 16 14 12 0 24 6 8 10 12 14 OUTPUT CURRENT A A-137 Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com OUTPUT VOLTAGE OUTPUT VOLTAGE V V (83.5) +0.5 89 5 - 99 (17.5)9.5 8.1 (27) RIPPLE mVp-p +0.5 65 +0.5 - 89 5 - Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com Ordering information Unit type AD 480 -24 AD480 123 1Series name 2Output wattage 3Output voltage AD Please refer to derating curve, because the rated load current depends on cooling method that is convention cooling or forced air. MODEL AD480-24 AD480-30 MAX OUTPUT WATTAGE[W] 480 300(Peak 720) ( ) DC OUTPUT 24V 20A 30V 10 Peak 24 A Forced air SPECIFICATIONS MODEL AD480-24 AD480-30 VOLTAGE[V] AC85 - 132 / 170 - 264 1 (User-selectable) f FREQUENCY[Hz] 47 - 440 EFFICIENCY[%] 85typ 85typ INPUT ACIN 100V 30max (Io=100%) INRUSH CURRENT[A] ( ) ACIN 200V 60max Io=100% ( , ) LEAKAGE CURRENT[mA] 1.0max 60Hz According to DEN-AN VOLTAGE[V] 24 30 ( ) ( ) Forced air 20 Peak 25 10 Peak 24 CURRENT[A] ( ) ( ) Convection 12 Peak 25 Ta=45 10 Peak 24 Ta=45 C C LINE REGULATION[mV] 300max 260max LOAD REGULATION[mV] 300max 420max *1 ( ) ( ) RIPPLE[mVp-p] 240max 0to+45 240max 0to+50 C C OUTPUT 1 RIPPLE NOISE[mVp-p] * 480max (0to+45 ) 480max (0to+50 ) C C ( ) ( ) TEMPERATURE REGULATION[mV] 500max 0to+45 600max 0to+50 C C 2 DRIFT[mV] * 100max 120max OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.6 - 26.4 28.5 - 33.0 ( , ) START-UP TIME[ms] 600max ACIN 100/200V Io=100% ( , ) HOLD-UP TIME[ms] 15typ ACIN 100/200V Io=100% OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically PROTECTION CIRCUIT REMOTE ON/OFF Use terminal RC and G , , , ( ) INPUT-OUTPUT AC1 500V 1minute Cutoff current = 10mA DC500V 100M min At Room Temperature W ISOLATION INPUT-FG AC1,500V 1minute, Cutoff current = 10mA, DC500V 100M min (At Room Temperature) W , , ( ) OUTPUT-FG AC500V 1minute Cutoff current = 50mA DC500V 100M min At Room Temperature W , , ( )( ), , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE 0to+65 20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max C STORAGE TEMP.,HUMID.AND ALTITUDE -25 to +80 , 10 - 95%RH (Non condensing), 9,000m (30,000feet) max C ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis CASE SIZE/WEIGHT 110 140 220mm (W H D) /3.0kg max X X X X OTHERS COOLING METHOD Forced air/Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. * When operated at pulse load, attach external capacitor at output line which is complying with the peak value of pulse current. A-138 Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com AD480 External view Voltage Adjust AD 4-M4 110 max 20 4.5 4.5 ¶1 200 +0.5 +0.5 65 Mounting Hole 75 - 4-M4 - H Mounting Hole AD480 ¶2 +V ¶2 V.ADJ +V -V -V RC SHORT RCG AC100V FG OPEN VS1 AC200V VS2 AC1 AC2 ¶1 ¶2 (17) 20.5 (30) +0.5 ¶1 165 4-M4 (17) - (81.5) Mounting Hole ¶1 M4 ¶Mounting torque ¶1: 1.5N•m(16kgf•cm)max ¶2 ¶Weight : 3.0kg or less ¶2: 1.2N•m(12.8kgf•cm)max ¶Tolerance : t1 ¶Dimensions in mm. Performance data STATIC CHARACTERISTICS RISE TIME & FALL TIME ¡ ¡ 24 Output Voltage 22 20 240 18 Io=100% Io=50% 16 150 AC100V Io=100% 14 Ripple 12 100 DC Output 10 AC Input 8 50 ACIN 100V 0 40 50 60 70 80 90 100 110 120 130 140 50ms/DIV INPUT VOLTAGE 60Hz V ( AC 100V ) OVERCURRENT CHARACTERISTICS DERATING CURVE ¡ ¡ 26 24 w 22 20 q 18 qConvection 3 wForced Air(0.5m /min) 16 14 12 0 510 15 20 25 30 OUTPUT CURRENT A A-139 Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com OUTPUT VOLTAGE V OUTPUT VOLTAGE V 140 12.5 + 0.5 115 - (33) (89) (19.5) (22.5) 8.1 9.5 RIPPLE mVp-p 4.5 +0.5 80 - 12.5 +0.5 115 - Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com Ordering information Unit type AD 960 -24 AD960 123 1Series name R 2Output wattage 3Output voltage AD RoHS : Please consult us for details Please refer to derating curve, because the rated load current depends on cooling method that is convention cooling or forced air. MODEL AD960-24 AD960-30 MAX OUTPUT WATTAGE[W] 960 960 Forced air 24V 40A 30V 32A DC OUTPUT Convection 24V 20(Peak 40)A 30V 16(Peak 32)A SPECIFICATIONS MODEL AD960-24 AD960-30 VOLTAGE[V] AC170 - 264 1 or DC240 - 370 f FREQUENCY[Hz] 47 - 440 or DC INPUT EFFICIENCY[%] 85typ 85typ ( ) INRUSH CURRENT[A] ACIN 200V 60typ Io=100% LEAKAGE CURRENT[mA] 1.0max (60Hz, According to UL, CSA , VDE and DEN-AN) VOLTAGE[V] 24 30 Forced air 40 32 CURRENT[A] 1 Convection* 20 (Peak 40) 16 (Peak 32) LINE REGULATION[mV] 200max 260max LOAD REGULATION[mV] 340max 420max 2 RIPPLE[mVp-p] -10to+45 * 240max 240max C OUTPUT *2 RIPPLE NOISE[mVp-p] -10to+45 480max 480max C TEMPERATURE REGULATION[mV] -10to+45 420max 520max C 3 DRIFT[mV] * 100max 120max OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 22.8 - 26.4 28.5 - 33.0 ( , ) START-UP TIME[ms] 600max ACIN 200V Io=100% HOLD-UP TIME[ms] 15typ (ACIN 200V, Io=100%) OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically PROTECTION CIRCUIT OVERVOLTAGE PROTECTION Works at 115 - 140% of rating INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 25mA, DC500V 50M min (At Room Temperature) W , , , ( ) ISOLATION INPUT-FG AC2 000V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature W , , ( ) OUTPUT-FG AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature W OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +65 , 10 - 90%RH (Non condensing)(Refer to DERATING CURVE), 3,000m (10,000feet) max C , , ( ), , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 10 - 90%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis SAFETY AND , , , AGENCY APPROVALS UL60950-1 CSA C22.2 No.234 EN60950-1 VDE0160 Complies with IEC950 NOISE CONDUCTED NOISE Complies with FCC-A REGULATIONS CASE SIZE/WEIGHT 89 141.6 230mm (without terminal block)(W H D) /3.0kg max X X X X OTHERS COOLING METHOD Forced air/Convection *1 For convection cooling, peak current for 10 seconds or less is acceptable, and output current must be less than 20A on average. *2 Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101). *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. * When operated at pulse load, attach external capacitor at output line which is complying with the peak value of pulse current. A-140 Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com AD960 External view ¶Mounting torque Voltage Adjust Name Plate Safety cover ¶1: 1.5N•m(16kgf•cm)max AD ¶2: 1.2N•m(12.8kgf•cm)max (12) 89 230 5.5 5.5 29 0.5 + + 0.5 +0.5 60 60 - 144 - - +V +V -V -V VB CB FG L N 4-M4 (19)(13) Mounting Hole ¶1 4-M4 4-M4 Terminal Block TB1(M4) Mounting Hole Mounting Hole ¶2 PIN ASSIGNMENT ¶2 (Bottom sides) 8-M4 ¶1 ¶1 Marking Function Mounting Hole + + V Output (Both sides) +V +Output - - V Output -V -Output ¶Dimensions in ( ) is for VB Voltage balance CB Current balance reference. Frame ground FG ¶Weight : 3.0kg or less L Input(L) ¶Tolerance : t 1 N Input(N) ¶2 ¶Dimensions in mm 5 ¶2 0.5 + 175 20A per pin maximum for TB1 - Performance data ¡STATIC CHARACTERISTICS ¡RISE TIME & FALL TIME 24 Output Voltage 22 250 20 18 Io=100% Io=50% 16 150 Io=100% 14 Ripple 100 12 DC Output 10 AC Input 50 8 ACIN 200V 0 80 100 120 140 160 180 200 220 240 260 100ms/DIV 20ms/DIV INPUT VOLTAGE V 60HZ ¡OVERCURRENT CHARACTERISTICS ¡DERATING CURVE 26 24 22 20 qConvection 3 wForced Air(0.5m /min) 18 16 14 12 0 10 20 30 40 50 OUTPUT CURRENT A A-141 Component Distributors, Inc. ~ www.cdiweb.com ~ 1-800-777-7334 ~ sales@cdiweb.com OUTPUT VOLTAGE OUTPUT VOLTAGE V V 141.6 12.5 +0.5 115 - (26) (93) 8.6 10 RIPPLE mVp-p 4.5 +0.5 12.5 75 +0.5 - 115- 12.5 +0.5 115 -
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the AD480-30 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods