Elite.Parts chervon right Manufacturers chervon right B chervon right BECKHOFF chervon right C3350
About product Datasheet FAQ

BECKHOFF C3350

Description

Beckhoff C3350 19-inch Panel PC

Part Number

C3350

Price

Request Quote

Manufacturer

BECKHOFF

Lead Time

Request Quote

Category

PRODUCTS - C

Datasheet

pdf file

C3350-978504700.pdf

1306 KiB

Extracted Text

Installation and Operating instructions for Build-in Industrial PC C33xx Version: 1.3 Date: 2007-02-09 General instructions Table of contents 1. General instructions 3 Notes on the Documentation 3 Liability Conditions 3 Description of safety symbols 3 Basic safety measures 4 Operator’s obligation to exercise diligence 5 Operator requirements 5 2. Product Description 6 Appropriate Use 6 Structure 6 Interfaces 9 PS/2-connectors 9 Parallel interface 9 Serial interfaces 9 VGA connection 9 USB interfaces 9 Network connection 9 Sound-On-Board 9 Additional plug-in cards (optional) 9 3. Installation Instructions 10 Transport and Unpacking 10 Transport 10 Unpacking 10 Installation of the PC in the control cabinet 11 Earthing measures 11 Power Supply Connection 12 Current carrying capacity of the 100-240 V power supply unit 12 Current carrying capacity of the 24 V power supply unit 12 Differently coded Connectors 13 Fitting the Power Supply Cable 13 Connecting devices 15 Connecting cables 15 Check voltage rating and connect 15 4. Operating Instructions 16 Switching the Industrial PC on and off 16 First switching on and driver installation 16 Operating the Industrial-PC 17 Description of the keys 17 Function keys 18 Special keys 18 Maintenance 19 Cleaning the Industrial PC 19 Replacing the battery on the motherboard 19 Servicing 19 Shutting down 19 Disposal 19 5. Troubleshooting 20 Fault correction 20 Service and Support 21 Beckhoff's branch offices and representatives 21 Beckhoff headquarters 21 Beckhoff Support 21 Beckhoff Service 21 C33xx 1 General instructions 6. Assembly dimensions 22 7. Appendix 26 Technical data 26 Approvals 26 FCC: Federal Communications Commission Radio Frequency Interference Statement 26 FCC: Canadian Notice 26 2 C33xx General instructions General instructions Notes on the Documentation This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components. Liability Conditions The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards. The documentation has been prepared with care. The products described are, however, constantly under development. For that reason the documentation is not in every case checked for consistency with performance data, standards or other characteristics. None of the statements of this manual represents a guarantee (Garantie) in the meaning of § 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of § 434 par. 1 sentence 1 BGB. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation. © This documentation is copyrighted. Any reproduction or third party use of this publication, whether in whole or in part, without the written permission of Beckhoff Automation GmbH, is forbidden. Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions. This symbol is intended to highlight risks for the life or health of personnel. Danger This symbol is intended to highlight risks for equipment, materials or the environment. Warning This symbol indicates information that contributes to better understanding. i Note C33xx 3 General instructions Basic safety measures Only switch the PC off after Before the Industrial PC is switched off, software that is running must closing the software be properly closed. Otherwise it is possible that data on the hard disk is lost. Please read the section on Switching the Industrial PC on and off. Switch off all parts of the equipment, then uncouple the fieldbus! Before opening the housing of the PC, and whenever the PC is being used Warning for purposes other than plant control, such as during functional tests following repair, all parts of the equipment must first be switched off, after which the Industrial PC can be uncoupled from the plant. Pulling out the fieldbus connection plug uncouples the PC (optional). Items of equipment that have been switched off must be secured against being switched on again. The Industrial PC’s power supply unit must be supplied with 100-240 V or AC 24 V (optional). DC Do not exchange any parts when under power! When components are being fitted or removed, the supply voltage must be Danger switched off. Fitting work on the Industrial PC can result in damage: • If metal objects such as screws or tools fall onto operating circuit boards. • If connecting cables internal to the PC are removed or inserted during operation. • If plug-in cards are removed or inserted when the PC is switched on. 4 C33xx General instructions Operator’s obligation to exercise diligence The operator must ensure that • the Industrial PC is only used for its intended use (see also chapter Product Description). • the Industrial PC is in a sound condition and in working order during operation. • the operation manual is in good condition and complete, and always available for reference at the location of the Industrial PC. • the Industrial PC is operated, maintained and repaired only by sufficiently qualified and authorised personnel. • the personnel is instructed regularly about relevant occupational safety and environmental protection aspects, and is familiar with the operating manual and in particular the safety notes contained herein. • none of the safety and warning notes attached to the Industrial PC are removed, and that all notes remain legible. National regulations Depending on the type of machine and plant in which the Industrial PC is depending on the machine being used, there will be national regulations for the control of such type machines and plant that the operator must observe. These regulations cover, amongst other things, the intervals between inspections of the controller. The operator must initiate such inspections in good time. Only trained persons may open the Industrial PC housing! The operator is responsible for ensuring that only trained electrical staff Warning opens the housing of the Industrial PC. Procedure in the event of a In the event of a fault in the Industrial PC, appropriate measures can be fault determined with the aid of the list in the Fault correction section. Operator requirements Read the operating Every user of the Industrial PC must have read these operating instructions instructions. Software knowledge Every user must be familiar with any of the functions of the software installed on the PC that he can reach. C33xx 5 Product Description Product Description Appropriate Use The C33xx Industrial PC is designed for mounting in control cabinets for machine and plant engineering applications. In addition to the PC with standard ATX-motherboard, a hard disk, floppy disk drive, machine-fair keyboard and a TFT display are integrated in a 19 inch rack. Structure Lockable front flap There is a lockable front flap above the display, behind which a floppy disk drive, a CD-ROM/ DVD drive (optional), status-LEDs, a reset button and a further lock for opening the front cover are located. Lock for opening the front flap (see arrow). When the front flap has been unlocked, it can be folded upwards. Front view of the Industrial PC C33xx with front flap opened Opening the housing The housing is opened from the front. Under the front flap there is a lock to open the front door (see arrow). The key differs from that the front flap, so that between users and service personnel can be differentiated administratively. The second lock is only to be opened by service technicians for the i purposes of fitting, extending or repairing the controller! The key must only Note be available to the service personnel. 6 C33xx Product Description Internal view of the PC 1 2 3 Behind the front door (1) is a 7 slot computer core with standard ATX motherboard (2) and power supply unit (3). Removing the drives 3 1 2 The drives (1, 2) can be removed without using any tool. After removing the card holder the plug-in cards (3) can be remoted. C33xx 7 Product Description Connections of the Industrial PC 4 2 1 3 The illustration shows the assembly of the PC (1) with excerpt frameworks (2) and telescope rails (3). The interface connections are at the side of the housing (4). Connections behind the The connections for the mouse (1) and the front flap keyboard (2) are located behind the front flap. 1 2 8 C33xx Product Description Interfaces Interfaces for the C33xx 3 10 11 1 12 4 5 6 8 2 13 7 9 Illustration turned around 90 degrees PS/2-connectors PS/2 The lower PS/2 connector (2) allows a keyboard to be used, while a PS/2 mouse can be connected to the upper PS/2 connector (1). If the PC is fitted with an optional Touch Pad also this PS/2 connection is occupied. Parallel interface Printer The parallel interface (3) corresponds to the Centronics standard, and is LPT1 addressed by the software as LPT1. Serial interfaces RS 232 The basic version of the Industrial PC has two serial interfaces, COM1 (4) COM1 – COM2 and COM2, using the type RS 232, which are each brought to a 9 pin SUB-D plug connector. The interface COM2 is located in the first slot right below the ATX-slot. One of the two seriell interfaces is used for connecting the special keys and the LEDs on the front side. If the PC is fitted with Touch Srcreen (optional), the second seriell interface is occupied too. VGA connection VGA A 15-pin SUB-D socket connector (5) allows a VGA monitor to be connected. USB interfaces USB1 – USB4 The four USB interfaces (6 – 9) are used to connect peripheral devices with USB connections. Network connection Network The RJ-45 connector (10) allows the PC to be connected to a Local Area Network (LAN). Sound-On-Board Sound The Industrial PC has a on-board-interface with the following connectors: Line In jack (11), Line Out jack (12) and Microphone jack (13). Additional plug-in cards (optional) Type plate A type plate is located on the upper side of the PC, providing information about the Industrial PC equipment as delivered. C33xx 9 Installation Instructions Installation Instructions Please also refer to chapter General instructions. Transport and Unpacking The specified storage conditions must be observed (see chapter Technical data). Transport Despite the robust design of the unit, the components are sensitive to strong vibrations and impacts. During transport, your Industrial PC should therefore be protected from excessive mechanical stress. Therefore, please use the original packaging. Danger of damage to the unit! Warning If the device is transported in cold weather or is exposed to extreme variations in temperature, make sure that moisture (condensation) does not form on or inside the device. Prior to operation, the unit must be allowed to slowly adjust to room temperature. Should condensation occur, a delay time of approximately 12 hours must be allowed before the unit is switched on. Unpacking Proceed as follows to unpack the unit: 1. Remove packaging. 2. Do not discard the original packaging. Keep it for future relocation. 3. Check the delivery for completeness by comparing it with your order. 4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. 10 C33xx Installation Instructions Installation of the PC in the control cabinet The C33xx Industrial PC is designed for mounting in control cabinets for machine and plant engineering applications. The ambient conditions specified for operation must be observed (see chapter Technical data). Preparation of the control Four holes for the fixing bolts have to be provided in the control cabinet cabinet according to the dimensions of the PC (see chapter Assembly dimensions). When the unit is installed in an enclosure, adequate space for i ventilation and for opening the PC must be provided. Note Please note the following points during installation of the PC: • Position the PC in such a way that reflections on the screen are avoided as far as possible. • Use the position of the screen as a guide for the correct installation height; it should be optimally visible for the user at all times. • The PC should not be exposed to direct sunlight. • When the unit is in its mounting position, the ventilation openings must not be obstructed. Extreme environmental conditions should be avoided as far as possible. Protect the PC from dust, moisture and heat. Warning The ventilation slots of the PC must not be covered. Earthing measures Earthing measures Earthing connections dissipate interference from external power supply cables, signal cables or cables to peripheral equipment. Establish a low-impedance connection from the earthing point on the PC housing (see photograph on the left) to the central earthing point on the control cabinet wall, in which the computer is being installed. C33xx 11 Installation Instructions Power Supply Connection The 5-pin CAGE CLAMP plug connector and mounting flange illustrated is located on the PC housing in order to connect the power supply. Socket at the PC housing Technical data Connecting socket Number of contacts 5 Contact spacing 5 mm Minimum conductor cross-section 1.5 mm² Minimum conductor cross-section 16 (AWG) Rated voltage (EN) 250 V Rated voltage (CSA) 300 V Current EN [A] 12 A Current CSA [A] 15 A Length of stripped conductor 8 to 9 mm Supplied mains power unit The Industrial PC is either fitted with a 100-240 V, 50-60 Hz power supply unit (standard) or with a 24 V power supply unit (with the option of an DC uninterruptible power supply, UPS). Current carrying capacity of the 100-240 V power supply unit Output voltages from Current loading Current carrying capacity the 100-240 V power maximum of the 100-240 V power supply unit supply unit +3.3 V 20 A +5 V stand by 2 A +5 V 25 A -5 V 0.3 A +12 V 13 A -12 V 0.8 A Current carrying capacity of the 24 V power supply unit Current carrying capacity Output voltages from Current loading the 24 V power supply maximum of the 24 V power supply unit unit +5 V 25 A -5 V 1 A +12 V 10 A -12 V 1.5 A 12 C33xx Installation Instructions Differently coded Connectors Coding pieces The connectors are coded differently at the factory, using snap-on coding pieces, according to the power supply unit that has been fitted. Differently coded plug connectors Coding for the 100-240 V , Coding for the 24 V power supply AC DC 50-60 Hz power supply unit unit Fitting the Power Supply Cable A 5-pin female plug connector with CAGE CLAMP connection and insertion catches is supplied along with a snap-on strain relief housing in order to assemble the PC power supply cable. Materials for assembly of the connector A B C D Female plug connector Strain relief housing Female plug connector is This female plug connector is also coded at the factory, according to the correspondingly coded type of power supply fitted, so that the plug, when assembled, will fit the Industrial PC’s connecting socket. Technical data Female plug connector Number of contacts 5 Contact spacing 5 mm Minimum conductor cross-section 1.5 mm² Minimum conductor cross-section 16 (AWG) Rated voltage (EN) 250 V Rated voltage (CSA) 300 V Current (EN) 16 A Current (CSA) 15 A Length of stripped conductor 8 to 9 mm C33xx 13 Installation Instructions Pin assignment and cable requirements Pin assignment There is an adhesive label with the pin assignments on the top of the female plug connector. The minimum permitted conductive cross- section is 1.5 mm², fused for 10 A (AWG 16). Industrial PCs with 100-240 V , 50-60 Hz power supply unit AC Pin assignment for the Pin Function 5 4 3 2 1 1 N 100 – 240V 100-240 V, 50-60 Hz power AC Power supply supply unit 2 L 3 4 not used 5 not used Industrial PCs with 24 V power supply unit DC Pin Function Pin assignment for the 24 V power supply unit 1 + 24V 5 4 3 2 1 DC DC Power supply 2 - 3 4 not used 5 not used Fitting the connector to the The plug is fitted to the cable as follows: cable 1. Strip insulation from the cable ends. Follow the technical data for the female plug connector in the above table! 2. Push the conductors into their mountings, simply by pushing them in as indicated on the pin assignment label. 3. Push the lower part (part A) of the strain relief housing (see photograph on page 13) onto the top of the female plug connector until it snaps into place. 4. Relieve the strain on the supply cable by fixing it in place with the cable clamp (part C) and fixing screws (part D) (see photograph below). Applying the strain relief Fix the upper part (part B) of the strain relief housing by snapping it onto the lower part. 14 C33xx Installation Instructions Connecting devices The power supply plug must be withdrawn! Warning Please read the documentation for the external devices prior to connecting them. During thunderstorms, plug connector must neither be inserted nor removed. When disconnecting a plug connector, always handle it at the plug. Do not pull the cable! Connecting cables The connections are located at the side of the Industrial PC and at the rear (power supply connection), and are documented in the section where the product is described. When connecting the cables to the Industrial PC, proceed according to the following sequence: • Switch off all the devices that are to be connected. • Disconnect all the devices that are to be connected from the power supply. • Connect all the cables between the Industrial PC and to the devices that are to be connected. • Connect all data transfer cables (if present) to the appropriate plug-in receptacles of the data/telecommunication networks. • Reconnect all devices to the power supply. Check voltage rating and connect With compact 100-240 V 50/60 Hz power supply: AC 1. Check that the mains voltage is correct. 2. Insert the power supply cable that you have assembled (see the section on Fitting the Power Supply Cable) into the Industrial PC's power supply socket. Then connect it to a power socket with a grounded earth connection. When fitted with the (optional) 24 V power supply unit: DC 1. Check that the external power supply is providing the correct voltage. 2. Insert the power supply cable that you have assembled (see the section on Fitting the Power Supply Cable) into the Industrial PC's power supply socket. Then connect it to your external 24 V power supply. If a 24 V UPS is installed, the correct type of rechargeable battery must be used. Warning C33xx 15 Operating Instructions Operating Instructions Please also refer to chapter General instructions. Switching the Industrial PC on and off Switch on The Industrial PC does not have its own mains switch. The Industrial PC will start when the equipment is switched on, or when it is connected to the power supply. Shutting down and When the plant is switched off, or when it is disconnected from its power switching off supply, the Industrial PC will be switched off. Control software such as is typically used on Industrial PCs permits various users to be given different rights. A user who may not close software may also not switch the Industrial PC off, since data can be lost from the hard disk by switching off while software is running. First shut down, then switch off the PC! If the Industrial PC is switched off as the software is writing a file to the Warning hard disk, the file will be destroyed. Control software typically writes something to the hard disk every few seconds, so that the probability of causing damage by switching off while the software is running is very high. When you have shut down the Industrial PC, you have to switch off power supply for at least 10 seconds before rebooting the system. Warning After resetting power supply the PC will start booting automatically. Reset-key A Reset button (1) for rebooting the system is provided under the front flap below the floppy disk drive. 2 1 Three LEDs are located next to the Reset button (2): LEDs The red LED signalises hard disk activity, the green LED signalises the presence of the voltage supply, while the yellow LED indicates Turbo operation. First switching on and driver installation When you switch on the Industrial PC for the first time, the pre-installed operating system (optional) will be started. In this case, all the required drivers for any additional, optional hardware components ordered with the PC will already have been installed. If the PC was ordered without operating system, you have to install the operating system and the driver software for any auxiliary hardware yourself. Please follow the instructions in the documentation for the operating system and the additional devices. 16 C33xx Operating Instructions Operating the Industrial-PC Type-dependent number of Depending on the precise type, the Industrial PC can have fewer keys than keys those described here. Description of the keys Operation The cursor is the blinking character that marks the point at which the next character entered will be displayed. The cursor is also known as the insertion point. The cursor keys each move the cursor one place in the associated direction. The Home key moves the cursor to the beginning of the line, while the End Home End key moves it to the end of the line. The Pg Up key scrolls one page back, the Pg Dn key scrolls one page Pg Up Pg Dn forward. The Tab key takes the cursor to the next input field, while Shift and Tab moves to the previous input field. The mouse cursor can be moved over the screen with the aid of the touch L R screen or of the touch pad (optional). The keys correspond to the left and right hand keys of a Microsoft mouse. Del The Del key deletes the character to the right of the cursor. The Ins key causes characters to the right of the cursor to be overwritten. Ins The overwrite mode is cancelled by pressing the key again. Print-Screen prints a hard copy of a text screen on the printer. Print The Pause key stops the computer until another key is pressed (only under Paus e MS-DOS). Your input is confirmed with the Enter key. Backspace deletes the character to the left of the cursor. If the Shift key is pressed at the same time as another key, then instead of Shif t the numbers you obtain the character printed above the number, and you obtain upper case letters instead of lower case letters. Pressing the Caps Lock key once activates and locks the Shift key. Ca p s Lock Pressing the Shift key cancels this function. Rather like the effect of the Shift key, Ctrl and Alt also change the meaning Ctr l Alt of another key that is pressed at the same time. Pressing this key opens the property sheet of the active (or marked) object. (Windows 95, 98, ME, NT, 2000, XP). Pressing this key opens the property sheet of the active (or marked) object. C33xx 17 Operating Instructions The Esc key has the effect of closing dialog windows and of interrupting some of the computer’s working operations. All other keys bring the character printed on them onto the display at the ! @ Q W 1 2 position of the cursor. ... Function keys F1 F2 F3 F 4 The meaning of the function keys, F1 to F10, is determined by the software and is displayed at the bottom edge of the display. F5 F6 F7 F 8 F9 F10 F 11 F 12 Special keys The function of the special keys left beside the display is also determined by the software. The function is displayed at the top edge of the display or by the marked module strips. The special keys each have an orange LED controlled by the software. 18 C33xx Operating Instructions Maintenance Please also refer to chapter General instructions. Cleaning the Industrial PC Switch off the Industrial PC and all connected devices, and disconnect the Industrial PC from the power supply. Danger The Industrial PC can be cleaned with a soft, damp cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches. Replacing the battery on the motherboard A used battery on the motherboard has to be replaced according to the rules of the board manufactorer. Danger of Explosion if battery is incorrectly replaced. Replace only with same or equivalent type recommended by the manufacturer. Dispose of Danger used batteries according to the manufacturer's instructions. Servicing The Industrial PC requires no maintenance. Shutting down Disposal Dismantling the Industrial The device must be fully dismantled in order to dispose of it. The housing PC can be sent for metal recycling. Observe national Electronic parts such as disk drives and circuit boards must be disposed of electronics scrap in accordance with national electronics scrap regulations. regulations C33xx 19 Troubleshooting Troubleshooting Please also refer to chapter General instructions. Pixel errors in the TFT display are production-caused and represent no complaint-reason! i Note Fault correction Fault Cause Procedure Nothing happens after the Industrial No power supply to the Industrial Check power supply cable. PC has been switched on PC. Other cause. Call Beckhoff Service. The Industrial PC does not boot Floppy disk or CD in the drive. Remove floppy disk or CD fully and press any key. Setup settings are incorrect. Check the setup settings. Other cause. Call Beckhoff Service. Computer boots, software starts, Cause of the fault is either in the Call the manufacturer of the but control does not operate software or in parts of the plant machine or the software. correctly outside the Industrial PC. Floppy disk or CD access error Faulty disk or CD. Check disk or CD in another drive. Faulty disk drive. Call Beckhoff Service. The Industrial PC functions only Defective components in the Call Beckhoff Service. partially or only part of the time, e.g. Industrial PC. no or dark picture, but disk drive responds when switching on 20 C33xx Troubleshooting Service and Support Beckhoff and their partners around the world offer comprehensive service and support, making available fast and competent assistance with all questions related to Beckhoff products and system solutions. Beckhoff's branch offices and representatives Please contact your Beckhoff branch office or representative for local support and service on Beckhoff products! The addresses of Beckhoff's branch offices and representatives round the world can be found on her internet pages: http://www.beckhoff.com You will also find further documentation for Beckhoff components there. Beckhoff headquarters Beckhoff Automation GmbH Eiserstraße 5 D-33415 Verl Germany Phone: +49(0)5246/963-0 Fax: +49(0)5246/963-198 e-mail: info@beckhoff.com Beckhoff Support Support offers you comprehensive technical assistance, helping you no only with the application of individual Beckhoff products, but also with other, wide-ranging services: • world-wide support • design, programming and commissioning of complex automation systems • and extensive training program for Beckhoff system components Hotline: +49(0)5246/963-157 Fax: +49(0)5246/963-9157 e-mail: support@beckhoff.com Beckhoff Service The Beckhoff Service Center supports you in all matters of after-sales service: • on-site service • repair service • spare parts service • hotline service Hotline: +49(0)5246/963-460 Fax: +49(0)5246/963-479 e-mail: service@beckhoff.com Quote the project number If servicing is required, please quote the project number of your Industrial PC. C33xx 21 Assembly dimensions Assembly dimensions The following pages show diagrams of the Industrial PCs, with dimensions in mm. The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial-PC C3320 screw mounting M3x10 through- hole for M4 screws screw mounting M3x10 front view side view cut out for installation plan view 22 C33xx Assembly dimensions The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial-PC C3330 screw mounting M3x10 through- hole for M4 screws screw mounting M3x10 front view side view plan view cut out for installation plan view with excerpt-frame for side view with excerpt-frame for front assembly front assembly C33xx 23 Assembly dimensions The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial-PC C3340 screw mounting M3x10 through- hole for M4 screws screw mounting M3x10 side view front view plan view cut out for installation plan view with excerpt-frame for side view with excerpt-frame for front assembly front assembly 24 C33xx Assembly dimensions The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial-PC C3350 screw mounting M3x10 through- hole for M4 screws screw mounting M3x10 front view side view cut out for installation plan view plan view with excerpt-frame for side view with excerpt-frame for front assembly front assembly C33xx 25 Appendix Appendix Technical data Industrial-PC C3320 Dimensions (W x H x D): 482,7 x 355 x 282 mm Weight: 18 kg (basic configuration) Industrial-PC C3330 Dimensions (W x H x D): 482,7 x 400 x 282 mm Weight: 18,5 kg (basic configuration) Industrial-PC C3340 Dimensions (W x H x D): 482,7 x 355 x 282 mm Weight: 18,5 kg (basic configuration) Industrial-PC C3350 Dimensions (W x H x D): 482,7 x 444 x 282 mm Weight: 19 kg (basic configuration) Do not use the PC in areas The Industrial PC may not be used in areas of explosive hazard. of explosive hazard The following conditions must be observed during operation: Environmental conditions Ambient temperature: 0 to 55°C Atmospheric humidity: Maximum 95%, non-condensing Shock resistance Sinusoidal vibration: (EN 60068-2-6) 10 to 58 Hz: 0.035 mm 2 58 to 500 Hz: 0.5 G (~ 5 m/ s) During reading of CD-ROM: 10 to 58 Hz: 0.019 mm 2 58 to 500 Hz: 0.25 G (~ 2.5 m/ s ) Impact: (EN 60068-2-27/ -29) 5 G (~ 50 m/ s²), duration: 30 ms During reading of CD-ROM: 5 G (~ 50 m/ s²), duration: 11 ms Protection class Protection class: IP 65 (front side), IP20 (back side) Power supply Supply voltage: 100-240 V 50-60 Hz 100-240 V power pack Power consumption: 100 W for the basic version AC Power supply 24 V Supply voltage: 24 V DC DC power pack (optional) Power consumption: 100 W for the basic version Electromagnetic Interference resistance: according to EN 61000-6-2 Compatibility (EMC) Emitted resistance: according to EN 61000-6-4 Transport and storage The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operation. The shock resistance during transport can be improved by means of suitably packing the Industrial PC. The ambient temperature during storage and transport must be between -20°C and +65°C. Pixel errors in the TFT display are production-caused and represent no complaint-reason! i Note Approvals FCC: Federal Communications Commission Radio Frequency Interference Statement FCC Approval for USA This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC: Canadian Notice FCC Approval for Canada This equipment does not exceed the Class A limits for radiated emissions as described in the Radio Interference Regulations of the Canadian Department of Communications. 26 C33xx

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the C3350 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

BECKHOFF INDUSTRIAL PC OPERATOR C3220TP

product

Beckhoff C3620 Industrial Panel PC. 5V Output | 4.5-5.5V DC Adj Input

product

Beckhoff C5101 19-inch slide-in Industrial PC

product

Beckhoff C5101-0030 19-inch slide-in Industrial PC

product

BECKHOFF C5102-0010 PC5000 Industrial PC with 2-Channel EtherNet PCI FC9002

product

Beckhoff CB4021 PC/104 Industrial Motherboard, CPU: AMD LX800, Integrated Video w/Intel® 551ER LAN