Specifications
Ambient temperature
-5°C to +50°C
Medium
Compressed air, filtered, lubricated and non-lubricated
Operating pressure
Maximum 8 bar
Operation
Spool valve indirectly actuated
Port sizes
Ø 3 mm, 4 mm, 6 mm Push-in fittings
Features
- All major Fieldbus protocols available
- Compact and lightweight
- Flexible design concept
- High flow from 10 mm valve width
- Interchangeable Fieldbus compatible modules
- Multipole or individually wired for installation flexibility
- Quick disconnect base (Pneumapole)
Datasheet
Extracted Text
Valve islands, VM10 series Valve slices 2 x 3/2, 5/2 and 5/3 with integral push-in fittings Ø 3 mm, 4 mm, 6 mm Multipole or individually wired for installation flexibility Interchangeable Fieldbus compatible modules Compact and lightweight Quick disconnect base (Pneumapole) High flow from 10 mm valve width Flexible design concept All major Fieldbus protocols available Technical data Ordering information To order please use valve island configurator Medium: available at www.norgren.com or use the Compressed air, filtered, lubricated and non-lubricated manual Valve Island Specification Form Operation: on page 20 Spool valve indirectly actuated Port sizes: Ø 3 mm, 4 mm, 6 mm Push-in fittings Imperial versions also available Operating pressure: Maximum 8 bar Flow: Function ‘C’ b’ ‘A’ l/min Cv Kv 5/2 port 1 to 2 & 4 1,77 0,48 7,10 430 0,44 0,36 5/2 ports 2 to 3 & 4 to 5 1,65 0,45 6,61 400 0,41 0,34 3/2 ports 1 to 2 & 1 to 4 1,44 0,39 5,78 350 0,36 0,29 3/2 ports 2 to 3 & 4 to 5 1,44 0,39 5,78 350 0,36 0,29 5/3 ports 1 to 2 & 4 1,44 0,39 5,78 350 0,36 0,29 5/3 ports 2 to 3 & 4 to 5 1,44 0,39 5,78 350 0,36 0,29 Degree of protection: Individually wired IP40 Multipole & Fieldbus IP65 Ambient temperature: Page -5°C to +50°C Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 (consult our Technical Service for use below +2°C) Accessories . . . . . . . . . . . . . . . . . . . . . . . . 4 Materials Multipole. . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Body, end plates: engineered PPA co-polymer Fieldbus . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Spool: aluminium Seals: nitrile rubber Pneumapole sub-base. . . . . . . . . . . . . . . 12 Fieldbus accessories . . . . . . . . . . . . . . . . 17 Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.01 without notice, the specifications given in this document. Valve islands, VM10 series 2 x 3/2 Double solenoid actuated valves Symbol Model Function Actuation Pilot supply Manual Operating Pilot pressure kg 2 x 3/2 override pressure (bar) (bar) 24 VM10*A11*B213B NC Sol/Spring Internal Turn & lock 3 ... 8 – 0,054 10 10 12 14 VM10*A11*B313B NC Sol/Spring Internal Push only 3 ... 8 – 0,054 3 1 5 24 VM10*A22*B213B NC Sol/Spring External Turn & lock -0,9 ... 8 3 ... 8 0,054 10 10 VM10*A22*B313B NC Sol/Spring External Push only -0,9 ... 8 3 ... 8 0,054 12 14 3 1 5 24 VM10*B11*B213B NO Sol/Spring Internal Turn & lock 3 ... 8 – 0,054 12 14 10 10 VM10*B11*B313B NO Sol/Spring Internal Push only 3 ... 8 – 0,054 3 1 5 24 VM10*B22*B213B NO Sol/Spring External Turn & lock -0,9 ... 8 3 ... 8 0,054 12 14 10 10 VM10*B22*B313B NO Sol/Spring External Push only -0,9 ... 8 3 ... 8 0,054 3 1 5 24 VM10*C11*B213B NC/NO Sol/Spring Internal Turn & lock 3 ... 8 – 0,054 12 10 10 14 VM10*C11*B313B NC/NO Sol/Spring Internal Push only 3 ... 8 – 0,054 3 1 5 24 VM10*C22*B213B NC/NO Sol/Spring External Turn & lock -0,9 ... 8 3 ... 8 0,054 12 10 10 14 VM10*C22*B313B NC/NO Sol/Spring External Push only -0,9 ... 8 3 ... 8 0,054 3 1 5 5/2 Single and double solenoid actuated valves Symbol Model Function Actuation Pilot supply Manual Operating Pilot pressure kg override pressure (bar) (bar) 42 VM10*517*B213B 5/2 Sol/Spring Internal Turn & lock 3 ... 8 – 0,044 14 12 VM10*517*B313B 5/2 Sol/Spring Internal Push only 3 ... 8 – 0,044 51 3 42 VM10*527*B213B 5/2 Sol/Spring External Turn & lock -0,9 ... 8 3 ... 8 0,044 12 VM10*527*B313B 5/2 Sol/Spring External Push only -0,9 ... 8 3 ... 8 0,044 14 51 3 42 VM10*511*B213B 5/2 Sol/Sol Internal Turn & lock 2 ... 8 – 0,054 14 12 VM10*511*B313B 5/2 Sol/Sol Internal Push only 2 ... 8 – 0,054 51 3 42 VM10*522*B213B 5/2 Sol/Sol External Turn & lock -0,9 ... 8 2 ... 8 0,054 12 VM10*522*B313B 5/2 Sol/Sol External Push only -0,9 ... 8 2 ... 8 0,054 14 12 51 3 5/3 Double solenoid actuated valves Symbol Model Function Actuation Pilot supply Manual Operating Pilot pressure kg override pressure (bar) (bar) 4 2 14 12 VM10*611*B213B 5/3 APB Sol/Sol Internal Turn & lock 3 ... 8 – 0,055 VM10*611*B313B 5/3 APB Sol/Sol Internal Push only 3 ... 8 – 0,055 12/14 1 5 3 4 2 14 12 VM10*622*B213B 5/3 APB Sol/Sol External Turn & lock -0,9 ... 8 3 ... 8 0,055 VM10*622*B313B 5/3 APB Sol/Sol External Push only -0,9 ... 8 3 ... 8 0,055 14 12 5 1 3 Note: For 5/3 COE please use 2 x 3/2 NC. For 5/3 COP please use 2 x 3/2 NO APB = All Ports Blocked COE = Centre Open Exhaust COP = Centre Open Pressure Note: * For selecting port sizes please see page 5.4.115.03 Warning These products are intended for use in industrial compressed air consider the failure modes of all component parts used in fluid power systems only. Do not use these products where pressures and systems and to provide adequate safeguards to prevent personal temperatures can exceed those listed under ‘Technical Data’. injury or damage to equipment in the event of such failure. Before using these products with fluids other than those specified, for System designers must provide a warning to end users in the non-industrial applications, life-support systems, or other applications system instructional manual if protection against a failure mode not within published specifications, consult NORGREN. cannot be adequately provided. Through misuse, age, or malfunction, components used in fluid power System designers and end users are cautioned to review specific systems can fail in various modes. The system designer is warned to warnings found in instruction sheets packed and shipped with these products. Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.02 without notice, the specifications given in this document. Valve islands, VM10 series Options selector VM10˙˙˙˙˙B˙13B Tube size Substitute Manual override Substitute 3 mm PIF 3 Turn to lock manual overide 2 4 mm PIF 4 Push only manual overide 3 6 mm PIF 6 1) No PIF (for use with Pneumapole) 7 Exhaust Substitute Standard open exhaust A Valve function Substitute 5/2 5 5/3 APB 6 Actuation/pilot supply Substitute 2 x 3/2 NC and 5/3 COE A Solenoid/solenoid internal pilot 11 2 x 3/2 NO and 5/3 COP B 2) Solenoid/spring internal pilot 17 2 x 3/2 NC and NO C Solenoid/solenoid external pilot 22 2) Note: For 5/3 COE and COP use 2 x 3/2 Solenoid/spring external pilot 27 APB = All Ports Blocked COE = Centre Open Exhaust COP = Centre Open Pressure For valve island specification see page 17 Use our configurator under http://www.norgren.com (also available on CD) 1) Requires Pneumapole sub-base 2) Can only be used with 5/2 valve Electrical details Solenoids 1) Voltage: 24 V d.c. 0,6 W Voltage tolerance: ± 10% Surge suppression: Flywheel diode Rating: 100% ED Indication: Yellow LED 1) 12 V d.c. also available. Please consult our Technical Service. Protection classification (IP code) AII VM10 multipole and fieldbus valve islands fulfil the IP65 rating. All VM10 individually wired valve islands fulfil the IP40 rating. UL/CSA approval Recognized to UL 429 - 5th edition & CSA 22.2 No.139 - 1982 for Electrically Operated Valves. ATEX The 24 V d.c. multipole and fieldbus valve islands fulfil the requirement of the standard 94/9/EC for intended use in hazardous locations. Equipment group, category, type of protection: II3 G EEx nA II T5X II3 D IP65 T90°C -15°C < tamb < 50°C Please review all ATEX data and notes in the installation and maintenance instruction leaflet to eliminate any risks, allowing for safe function of the valve islands. LABS free testing to standard LPV 0700.99000 VM10 has been tested by the Fraunhofer Institut IPA in Stuttgart and complies with Daimler Chrysler Standard LPV 0700.99000. This is a specification for the automotive industry which requires a product to be satisfactory in lacquer or paint spraying environments – no grease to be exposed to the article, being sprayed, by the product (via the compressed air or the packaging) Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.03 without notice, the specifications given in this document. Valve islands, VM10 series Accessories D Sub-connector 25 pin D Sub-connector 44 pin 2 Pin connector Valve blanking station Port blanking station IP65 IP65 IP40 V11569-E01 1 m L1 V11570-E01 1 m M1 V11556-E10 1 m K2 VM106517AQ0300 B000 VM106517AQ0301 Port 1 blanked B100 V11569-E03 3 m L2 V11570-E03 3 m M2 V11556-E03 0,3 m K1 VM106517AQ0302 Ports 3 & 5 blanked B300 V11569-E05 5 m L3 V11570-E05 5 m M3 VM106517AQ0303 Ports 1, 3 & 5 blanked B500 Pressure switch DIN Rail DIN Rail fixing kit Manual override set-up kit (x2) Pneumapole sub-base VM106517AQ0804 4 mm 7A V10009-C00 1 m A17 V11900-C01 8D V11574-K30 Push only N1 For part numbers and dimensional details see page 12 & 13 VM106517AQ0806 6 mm 7B V11574-K31 Turn to lock N2 D Sub-connector 25 pin 90° D Sub-connector 44 pin 90° Label cover kit Labels Right handed Left handed V12086-E01 1 m L4 V12088-E01 1m M4 V12016-K36 4 Station G1 V12033-L02 Write and seal label J1 V12086-E03 3 m L5 V12088-E03 3m M5 V12016-K37 6 Station G2 V12034-L02 Paper label J5 V12086-E05 5 m L6 V12088-E05 5m M6 V12016-K38 8 Station G3 V12016-K39 10 Station G4 V12016-K40 12 Station G5 V12016-K41 16 Station G6 VM10 models Single solenoid Double solenoid Blanking plates 5/3 APB Double solenoid 4 6 6 6 6 2 4 6 66 6 2 4 6 6 6 2 6 78,5 78,5 78,5 78,5 5 2 1 2 1 1 2 32 32 15 15 32 15 Short code Short code kg Valve blanking station Port blanking station VM106517AQ0300 B000 VM106517AQ0301 Port 1 blanked B100 0,028 VM106517AQ0302 Ports 3 & 5 blanked B300 0,028 VM106517AQ0303 Ports 1, 3 & 5 blanked B500 0,028 Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.04 without notice, the specifications given in this document. 53 11,5 10,6 53 11,5 10,6 10,6 56 53 11,5 10,6 M4 M4 Valve islands, VM10 series Port connections 76 + (10,6 x N) 21,5 19 + (10,6 x N) 18,5 53 3 6 11 1 4 15 10,6 5 3 4 5 Panel cut-out detail 1 For mounting island from outside of panel using M4 threads in valve island end plates 2 For using through-mounting holes in valve island end plates 3 Ports 12/14 52 + (N x 10,6) 4 Ports 1, 3 & 5 63 + (N x 10,6) 5 Ports 82/84 N = number of stations Detailed CAD drawings available through website valve island configurator Model Description BA C Short kg Ports 1 ,3 & 5 Ports 12/14 & 82/84 Ports 2 & 4 code VM106517AQ010Y End plate kit - feed both ends 10 mm 6 mm 6 mm F100 0,170 VM106517AQ0108 End plate kit - feed both ends 8 mm 4 mm 4 mm F800 0,170 VM106517AQ011Y End plate kit - feed left, right blocked 10 mm 6 mm 6 mm L100 0,170 VM106517AQ0118 End plate kit - feed left, right blocked 8 mm 4 mm 4 mm L800 0,170 VM106517AQ012Y End plate kit - feed right, left blocked 10 mm 6 mm 6 mm R100 0,170 VM106517AQ0128 End plate kit - feed right, left blocked 8 mm 4 mm 4 mm R800 0,170 1) 1) 1) VM106517AQ0131 End plate kit - feed both ends no PIF no PIF no PIF FP00 0,170 1) 1) 1) VM106517AQ0132 End plate kit - feed left, right blocked no PIF no PIF no PIF RP00 0,170 1) 1) 1) VM106517AQ0133 End plate kit - feed right, left blocked no PIF no PIF no PIF LP00 0,170 Available valve port sizes – Ø 3 mm, 4 mm and 6 mm 1) No push in fitting for use with pneumapole sub-base Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.05 without notice, the specifications given in this document. 78,5 75 58,5 48 48 4,5 5 1 2 30 15 M4 4,8 M4 M4 82/84 5 1 3 12/14 4 2 4 2 4 2 4 2 2 4 2 4 4 2 4 2 5 1 3 82/84 12/14 Valve islands, VM10 series Modular assembly Individually wired IP40 1) Individually wired No. of stations Max. no. coils kg 2 Pin connector 2 ... 20 40 0,170 1) kg + valves weight 38 53 10,6 11,5 76 + (N x 10,6) 56,5 N = number of stations Multipole IP65 Multipole No. of stations -ve common Model Short code +ve common Model Short code Max. no. coils kg 25 Pin connector 4 VM106517AQ0404 2N04 VM106517RQ0404 2P04 8 0,116 25 Pin connector 6 VM106517AQ0406 2N06 VM106517RQ0406 2P06 12 0,122 25 Pin connector 8 VM106517AQ0408 2N08 VM106517RQ0408 2P08 16 0,128 25 Pin connector 10 VM106517AQ0410 2N10 VM106517RQ0410 2P10 20 0,134 25 Pin connector 12 VM106517AQ0412 2N12 VM106517RQ0412 2P12 24 0,140 44 Pin connector 10 VM106517AQ0510 4N10 VM106517RQ0510 4P10 20 0,138 44 Pin connector 12 VM106517AQ0512 4N12 VM106517RQ0512 4P12 24 0,144 44 Pin connector 16 VM106517AQ0516 4N16 VM106517RQ0516 4P16 32 0,160 80 1 43,3 10,6 83 86,5 76 + (N x 10,6) N = number of stations 1 25 Pin connector for 4, 6, 8, 10 & 12 station 44 Pin connector for 10, 12 & 16 station Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.06 without notice, the specifications given in this document. 78,5 78,5 5 Valve islands, VM10 series Fieldbus connections (M12 connector types IP65) Model Standard fieldbus No. of stations Max. no. coils Short code kg 1) VM10AS10A00410 AS-interface 04 4 A404 0,138 2) 1) VM10AS10A00810 AS-interface 08 8 A808 0,144 2) 1) VM10AS10A00820 AS-interface 04 8 A804 0,150 2) 1) VM10AS10A00830 AS-interface 06 8 A806 0,170 VM10DNFNB00082 DeviceNet 08 16 DR08 0,138 VM10DNFNB00102 DeviceNet 10 20 DR10 0,144 VM10DNFNB00122 DeviceNet 12 24 DR12 0,150 VM10DNFNB00162 DeviceNet 16 32 DR16 0,170 VM10CAFNB00082 CANopen 08 16 CR08 0,138 VM10CAFNB00102 CANopen 10 20 CR10 0,144 VM10CAFNB00122 CANopen 12 24 CR12 0,150 VM10CAFNB00162 CANopen 16 32 CR16 0,170 1) Number of stations = 04 (4 x sol/spring), 08 (8 x sol/spring), 04 (4 x sol/sol), 06 (4 x sol/spring, 2 x sol/sol). 2) Use 2 x M12 protocol connectors 80 1 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 2 2 99,5 43,3 10,6 76 + (N x 10,6) 102,5 1 M12 power connector 2 M12 protocol connector N = number of stations (AS-i version shown) Connector details Power connection Pin no. Function Tolerance Max. current Male 1 24 VB Logic circuit supply ±30% 300 mA 4 3 2 24 VA Valves ±10% 1,5 A 3 0 V – 1,53 A 4 Earth – – 1 2 Looking into node connector Pin no. Function AS-i 1 AS-i v+ 2 3 2– 3 AS-i v- 4– 1 4 DeviceNet & CANopen Pin no. Function 1 Drain 2V+ 4 3 3V- 5 4 CAN_H 5 CAN_L 1 2 Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.07 without notice, the specifications given in this document. 78,5 5 Valve islands, VM10 series Fieldbus connections (M12 connector types IP65) Model Standard Fieldbus No. of stations Max. no. coils Short code kg VM10DPFNB00082 Profibus-DP 08 16 PS08 0,138 VM10DPFNB00102 Profibus-DP 10 20 PS10 0,144 VM10DPFNB00122 Profibus-DP 12 24 PS12 0,150 VM10DPFNB00162 Profibus-DP 16 32 PS16 0,170 1) – AB RIO 08 16 – – 1) – AB RIO 10 20 – – 1) – AB RIO 12 24 – – 1) – AB RIO 16 32 – – 1) For AB RIO requirements, please consult our Technical Service. 80 1 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 2 3 43,3 10,6 99,5 102,5 76 + (N x 10,6) 1 M12 power connector 2 M12 protocol connector N = number of stations Connector details Power connection Male Pin no. Function Tolerance Max. current 1 24 VB Logic circuit supply ±30% 300 mA 4 3 2 24 VA Valves ±10% 1,5 A 3 0 V – 1,53 A 4 Earth – – 1 2 Looking into node connector Profibus-DP Male Female Pin no. Function Communication in Communication out 1 5 VI Opto isolator 2 A-line (green) 4 3 3 4 3 0 VI Opto isolated 4 B-line (red) 5 5 5 Shield 1 2 2 1 Threaded joint Shield AB-RIO (Bus) Pin no. Function 1 RIO 1 4 3 3 4 2– 3 RIO 2 5 5 4– 1 2 2 1 5 RIO SH Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.08 without notice, the specifications given in this document. BAUD/QTR RACK 78,5 5 Valve islands, VM10 series Fieldbus connections - (9 pin D-type connector IP40) Model Standard Fieldbus Max. no. coils No. of stations Short code kg VM10IBFNB00080 Interbus-S 8 16 S008 0,138 VM10IBFNB00100 Interbus-S 10 20 S010 0,144 VM10IBFNB00120 Interbus-S 12 24 S012 0,150 VM10IBFNB00160 Interbus-S 16 32 S016 0,170 80 1 2 2 99,5 43,3 10,6 102,5 76 + (N x 10,6) 1 M12 power connector 2 9 pin protocol connector N = number of stations Connector details Outgoing Remote Bus D-Sub Connector (Female) Incoming Remote Bus D-Sub Connector (Male) Male Female Pin Number Signal Pin Number Signal 1DO 1 D0 2DI 2 DI 3 0VI 3 0VI 1) 1) 4 4 2) 1) 5 +5VI 5 6 /DO 6 /DO 7 /DI 7 /DI 1) 1) 8 8 2) 9 RBST 9– Looking into node connector 1) Do not connect to pins 4 or 8 2) If used, the outgoing bus connector should have pins 5 and 9 connected together to indicate the presence of a device on the outgoing bus. Power connection Male Pin no. Function Tolerance Max. current 1 24 VB Logic circuit supply ±30% 300 mA 4 3 2 24 VA Valves ±10% 1,5 A 3 0 V – 1,53 A 4 Earth – – 1 2 Looking into node connector Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.09 without notice, the specifications given in this document. 78,5 5 Valve islands, VM10 series Fieldbus connections - (9 pin D-type connector IP40) Model Standard Fieldbus No. of stations Max. no. coils Short code kg VM10DPFNB00083 Profibus-DP 8 16 PR08 0,138 VM10DPFNB00103 Profibus-DP 10 20 PR10 0,144 VM10DPFNB00123 Profibus-DP 12 24 PR12 0,150 VM10DPFNB00163 Profibus-DP 16 32 PR16 0,170 80 1 2 43,3 99,5 10,6 76 + (N x 10,6) 102,5 1 M12 power connector 2 M12 protocol connector N = number of stations Connector details Female Pin Number Function 1 Shield 2 N/C 3 B-line (Red) RxD / TxD-P 4 CNTR-P (RTS) 5 DGND (OVI) opto Isolated 6 VP (5VI) opto Isolated 7 N/C 8 A-line (Green) RxD / TxD-N 9 CNTR-N (direction control) Looking into node connector Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.10 without notice, the specifications given in this document. X1 X10 78,5 5 MSD LSD Valve islands, VM10 series Fieldbus connections with interlocks IP65 Model Standard Fieldbus No. of stations Max. no. coils Short code kg VM10DNFNB00083 DeviceNet 8 16 DK08 0,138 VM10DNFNB00103 DeviceNet 10 20 DK10 0,144 VM10DNFNB00123 DeviceNet 12 24 DK12 0,150 VM10DNFNB00163 DeviceNet 16 32 DK16 0,170 80 1 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 2 3 43,3 10,6 99,5 76 + (N x 10,6) 102,5 1 Rotary address switch 2 M12 protocol connector 3 44 way 'D' interlocked power connector N = number of stations Connector details 44 way 'D' interlocked power connections Valve/Sol 8 10 12 16 Valve/Sol 8 10 12 16 1-a 16 20 24 32 1-b 15 19 23 31 2-a 14 18 22 30 2-b 13 17 21 29 3-a 12 16 20 28 3-b 11 15 19 27 4-a 10 14 18 26 4-b 9 13 17 25 5-a 8 12 16 24 5-b 7 11 15 23 6-a 6 10 14 22 6-b 5 9 13 21 7-a 4 8 12 20 7-b 3 7 11 19 8-a 2610 18 8-b 15917 9-a N/A 4 8 16 9-b N/A 3 7 15 10-a N/A 2 6 14 10-b N/A 1 5 13 11-a N/A N/A 4 12 11-b N/A N/A 3 11 12-a N/A N/A 2 10 12-b N/A N/A 1 9 13-a N/A N/A N/A 8 13-b N/A N/A N/A 7 14-a N/A N/A N/A 6 14-b N/A N/A N/A 5 15-a N/A N/A N/A 4 15-b N/A N/A N/A 3 16-a N/A N/A N/A 2 16-b N/A N/A N/A 1 Looking into node connector Common 44 44 44 44 Common 44 44 44 44 Fieldbus Pin no. Function DeviceNet & CANopen 1 Drain 2V+ 4 3 3V- 5 4 CAN_H 5 CAN_L 1 2 Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.11 without notice, the specifications given in this document. 78,5 5 Valve islands, VM10 series Pneumapole sub-base – bottom ported Model Description AB C Exhaust type Short code Ports 1, 3 & 5 Ports 12/14 & 82/84 Ports 2 & 4 VM106517AQ6604 4 station Pneumapole 10 mm 6 mm 6 mm Standard 6B04 VM106517AQ6606 6 station Pneumapole 10 mm 6 mm 6 mm Standard 6B06 VM106517AQ6608 8 station Pneumapole 10 mm 6 mm 6 mm Standard 6B08 VM106517AQ6610 10 station Pneumapole 10 mm 6 mm 6 mm Standard 6B10 VM106517AQ6612 12 station Pneumapole 10 mm 6 mm 6 mm Standard 6B12 VM106517AQ6616 16 station Pneumapole 10 mm 6 mm 6 mm Standard 6B16 4 3 18,5 A 18,5 15,3 15,3 30 6 10,6 6 22,5 1 4 14,8 14,84M4 4 Max 21 3 M6 M4 10 M4 5 1 x 8 mm deep 2 x 12 mm deep 3 Side mounting option. Centre clamp to be removed if utilised. x 11 mm deep (12 & 16 station version only) 4 2,5 22 22 B 15 15 Panel cut-out detail No. ofAB stations 4 111,0 92,0 6 132,0 113,5 8 153,0 134,5 10 174,0 155,8 12 195,0 177,0 16 237,0 219,5 B A Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.12 without notice, the specifications given in this document. 79 92,5 75,5 71,5 71,5 5 15,5 58,5 48 8 30 14,5 4,5 M4 2 15 10,5 48 30 86,5 58,5 7,5 7,5 71,5 106 Valve islands, VM10 series Pneumapole sub-base – side ported Model Description AB C Exhaust type Short code Ports 1, 3 & 5 Ports 12/14 & 82/84 Ports 2 & 4 VM106517AQ6S04 4 station Pneumapole 10 mm 6 mm 6 mm Standard 6S04 VM106517AQ6S06 6 station Pneumapole 10 mm 6 mm 6 mm Standard 6S06 VM106517AQ6S08 8 station Pneumapole 10 mm 6 mm 6 mm Standard 6S08 VM106517AQ6S10 10 station Pneumapole 10 mm 6 mm 6 mm Standard 6S10 VM106517AQ6S12 12 station Pneumapole 10 mm 6 mm 6 mm Standard 6S12 VM106517AQ6S16 16 station pneumapole 10 mm 6 mm 6 mm Standard 6S16 A 15,5 14,8 10,6 15,5 M5 3 A 22 47 22 11,5 12,5 6 6 12,5 8 44 ø 3 8 A 3 4 21 1 x 8 mm deep 22,5 22,5 2 x 8 mm deep 18,5 18,5 x 10 mm deep 3 4,5 4,5 x 11 mm deep (12 & 16 station version only) 4 x 4,5 mm deep 5 Additional cut-out required when rear 6 mounting 12 & 16 station versions 3 B 25 Panel cut-out detail 6 No. ofAB stations 4 92,5 80,0 6 113,8 101,0 8 135,0 122,0 10 156,3 143,0 C 12 177,5 164,0 D 16 220,0 206,0 Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.13 without notice, the specifications given in this document. 93 83 63 30 55,5 22,5 27 20 6 7,5 5 12 48 16 3 4,5 7,5 15 M4 2 9,5 30 13 86,5 5,5 32 30 17 30 63 Valve islands, VM10 series Multi-pressure options Single pressure Dual pressure Pressure 1 Pressure 1 Pressure 2 Blanking slice Gallery 1 VM106517AQ0301 Three pressure Four pressure Pressure 2 Pressure 1 Pressure 3 Port 3 Port 3a Port 3b Pressure 1 Port 1 Pressure 3 Pressure 2 Pressure 4 Port 5 Port 5a Port 5b Blanking slice Blanking slice Galleries 3 and 5 Galleries 1, 3 and 5 VM106517AQ0302 VM106517AQ0303 3 & 4 pressure systems can only be achieved using externally piloted 2 x 3/2 valves Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.14 without notice, the specifications given in this document. Valve islands, VM10 series 25 pin D sub-connector (IP65) 44 pin D Sub-connector (IP65) A A 3.9 (100) 100 30 5 0.19 (5) 44 15 25 13 14 1 31 16 1 ModelAk Short codeg ModelAk Short codeg V11569-E01 1 m L1 0,276 V11570-E01 1 m M1 0,280 V11569-E03 3 m L2 0,676 V11570-E03 3 m M2 0,680 V11569-E05 5 m L3 1,076 V11570-E05 5 m M3 1,080 Pin no. Wire colour Socket Pilot Station Pin no. Wire colour Socket Pilot Station 1 White Solenoid 1–a 14 1 1 White Solenoid 1–a 14 1 2 Brown Solenoid 2–a 14 2 2 Brown Solenoid 2–a 14 2 3 Green Solenoid 3–a 14 3 3 Green Solenoid 3–a 14 3 4 Yellow Solenoid 4–a 14 4 4 Yellow Solenoid 4–a 14 4 5 Grey Solenoid 5–a 14 5 5 Grey Solenoid 5–a 14 5 6 Pink Solenoid 6–a 14 6 6 Pink Solenoid 6–a 14 6 7 Blue Solenoid 7–a 14 7 7 Blue Solenoid 7–a 14 7 8 Red Solenoid 8–a 14 8 8 Red Solenoid 8–a 14 8 9 Black Solenoid 9–a 14 9 9 Black Solenoid 9–a 14 9 10 Violet Solenoid 10–a 14 10 10 Violet Solenoid 10–a 14 10 11 Grey/Pink Solenoid 11–a 14 11 11 Grey/Pink Solenoid 11–a 14 11 12 Red/Blue Solenoid 12–a 14 12 12 Red/Blue Solenoid 12–a 14 12 13 White/Green Common-Ve – 13 White/Green Solenoid 13–a 14 13 14 Brown/Green Solenoid 1–b 12 1 14 Brown/Green Solenoid 14–a 14 14 15 White/Yellow Solenoid 2–b 12 2 15 White/Yellow Solenoid 15–a 14 15 16 Yellow/Brown Solenoid 3–b 12 3 16 Yellow/Brown Solenoid 1–b 12 1 17 White/Grey Solenoid 4–b 12 4 17 White/Grey Solenoid 2–b 12 2 18 Grey/Brown Solenoid 5–b 12 5 18 Grey/Brown Solenoid 3–b 12 3 19 White/Pink Solenoid 6–b 12 6 19 White/Pink Solenoid 4–b 12 4 20 Pink/Brown Solenoid 7–b 12 7 20 Pink/Brown Solenoid 5–b 12 5 21 White/Blue Solenoid 8–b 12 8 21 White/Blue Solenoid 6–b 12 6 22 Brown/Blue Solenoid 9–b 12 9 22 Brown/Blue Solenoid 7–b 12 7 23 White/Red Solenoid 10–b 12 10 23 White/Red Solenoid 8–b 12 8 24 Brown/Red Solenoid 11–b 12 11 24 Brown/Red Solenoid 9–b 12 9 25 White/Black Solenoid 12–b 12 12 25 White/Black Solenoid 10–b 12 10 Note: Conforms to DIN 47100 26 Brown/Black Solenoid 11–b 12 11 27 Grey/Green Solenoid 12–b 12 12 28 Yellow/Grey Solenoid 13–b 12 13 29 Pink/Green Solenoid 14–b 12 14 30 Yellow/Pink Solenoid 15–b 12 15 Pressure switch 31 Green/Blue Solenoid 16–a 14 16 32 Yellow/Blue Solenoid 16–b 12 16 ModelAk Short codeg 33 - NOT USED - - VM106517AQ0804 4 7A 0,004 34 - NOT USED - - VM106517AQ0806 6 7B 0,004 35 - NOT USED - - 36 - NOT USED - - AMP E–terminals 2,8 x 0,8 3 37 - NOT USED - - Degree of protection: IP 00 p 38 - NOT USED - - Non adjustable Pressure range: 0 ... 10 bar 39 - NOT USED - - Switching point rising pressure: 3,0 ... 5,0 40 - NOT USED - - 1 Switch point falling pressure: 2,5 ... 3,7 bar 41 - NOT USED - - 42 - NOT USED - - 31,5 43 - NOT USED - - 17 44 Red/Black Yellow/Black Common -Ve - - Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.15 without notice, the specifications given in this document. A Valve islands, VM10 series D Sub-connector 25 pin 90° D Sub-connector 44 pin 90° A A A A 25 13 31 16 1 100 100 5 5 14 1 44 30 15 A A Model Short code Model Short code Akg Akg V12088-E01 1m M4 0,280 V12086-E01 1 m L4 0,275 V12088-E03 3m M5 0,680 V12086-E03 3 m L5 0,675 V12088-E05 5m M6 1,080 V12086-E05 5 m L6 1,075 Pin no. Wire colour Socket Pilot Station Pin no. Wire colour Socket Pilot Station 1 White Solenoid 1–a 14 1 1 White Solenoid 1–a 14 1 2 Brown Solenoid 2–a 14 2 2 Brown Solenoid 2–a 14 2 3 Green Solenoid 3–a 14 3 3 Green Solenoid 3–a 14 3 4 Yellow Solenoid 4–a 14 4 4 Yellow Solenoid 4–a 14 4 5 Grey Solenoid 5–a 14 5 5 Grey Solenoid 5–a 14 5 6 Pink Solenoid 6–a 14 6 6 Pink Solenoid 6–a 14 6 7 Blue Solenoid 7–a 14 7 7 Blue Solenoid 7–a 14 7 8 Red Solenoid 8–a 14 8 8 Red Solenoid 8–a 14 8 9 Black Solenoid 9–a 14 9 9 Black Solenoid 9–a 14 9 10 Violet Solenoid 10–a 14 10 10 Violet Solenoid 10–a 14 10 11 Grey/Pink Solenoid 11–a 14 11 11 Grey/Pink Solenoid 11–a 14 11 12 Red/Blue Solenoid 12–a 14 12 12 Red/Blue Solenoid 12–a 14 12 13 White/Green Common-Ve – 13 White/Green Solenoid 13–a 14 13 14 Brown/Green Solenoid 1–b 12 1 14 Brown/Green Solenoid 14–a 14 14 15 White/Yellow Solenoid 2–b 12 2 15 White/Yellow Solenoid 15–a 14 15 16 Yellow/Brown Solenoid 3–b 12 3 16 Yellow/Brown Solenoid 1–b 12 1 17 White/Grey Solenoid 4–b 12 4 17 White/Grey Solenoid 2–b 12 2 18 Grey/Brown Solenoid 5–b 12 5 18 Grey/Brown Solenoid 3–b 12 3 19 White/Pink Solenoid 6–b 12 6 19 White/Pink Solenoid 4–b 12 4 20 Pink/Brown Solenoid 7–b 12 7 20 Pink/Brown Solenoid 5–b 12 5 21 White/Blue Solenoid 8–b 12 8 21 White/Blue Solenoid 6–b 12 6 22 Brown/Blue Solenoid 9–b 12 9 22 Brown/Blue Solenoid 7–b 12 7 23 White/Red Solenoid 10–b 12 10 23 White/Red Solenoid 8–b 12 8 24 Brown/Red Solenoid 11–b 12 11 24 Brown/Red Solenoid 9–b 12 9 25 White/Black Solenoid 12–b 12 12 25 White/Black Solenoid 10–b 12 10 Note: Conforms to DIN 47100 26 Brown/Black Solenoid 11–b 12 11 27 Grey/Green Solenoid 12–b 12 12 28 Yellow/Grey Solenoid 13–b 12 13 29 Pink/Green Solenoid 14–b 12 14 30 Yellow/Pink Solenoid 15–b 12 15 31 Green/Blue Solenoid 16–a 14 16 32 Yellow/Blue Solenoid 16–b 12 16 33 - NOT USED - - 34 - NOT USED - - 35 - NOT USED - - 36 - NOT USED - - 37 - NOT USED - - 38 - NOT USED - - 39 - NOT USED - - 40 - NOT USED - - 41 - NOT USED - - 42 - NOT USED - - 43 - NOT USED - - 44 Red/Black Yellow/Black Common -Ve - - Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.16 without notice, the specifications given in this document. Valve islands, VM10 series Fieldbus accessories Description Connection Cable length Model Short code Fieldbus power connector DeviceNet (4 pin, female) M12 Wireable V11588-E01 R1 CANopen (4 pin, female) AB RIO (4 pin, female) Profibus-DP (4 pin, female) Interbus-S (4 pin, female) Fieldbus power cables M12 straight to open end M12 1 m FD676U84S74003 C1 2,5 m FD676U84S74006 C2 5 m FD676U84S7400B C3 M12 90° to open end M12 1 m FD676U84A74003 C4 2,5 m FD676U84A74006 C5 5 m FD676U84A7400B C6 Interlock power connector DeviceNet or CANopen (44 pin, female) D-Sub 1 m V11570-E01 M1 3 m V11570-E03 M2 5 m V11570-E05 M3 Communication cable and connector Profibus straight M12 0,3 m FD677UP3SG3S11 A1 1 m FD677UP3SG3S13 A2 2 m FD677UP3SG3S15 A3 DeviceNet/CANopen straight M12 0,3 m FD678UD5SH5S11 B1 1 m FD678UD5SH5S13 B2 2 m FD678UD5SH5S15 B3 Profibus 90° M12 0,3 m FD677UP3AG3A11 A4 1 m FD677UP3AG3A13 A5 2 m FD677UP3AG3A15 A6 DeviceNet/CANopen 90° M12 0,3 m FD678UD5AH5A11 B4 1 m FD678UD5AH5A13 B5 2 m FD678UD5AH5A15 B6 DeviceNet (5 pin, female) M12 Wireable V11589-E01 R2 CANopen (5 pin, female) AB RIO (5 pin, female) Profibus-DP, reverse keyway M12 Wireable V11590-E01 R3 (5 pin, female) Profibus-DP, reverse keyway M12 Wireable V11591-E01 R4 (5 pin male) Profibus-DP connector D-Sub Wireable V11654-E01 R0 (9 pin, male with terminating resistor) IP40 Profibus - DP terminating resistor M12 – V11592-E01 R6 AS-interface power or communications M12 Wireable VE1ASCN1-M1200 R5 (4 pin) Interbus-S (9 pin) D-Sub 1 m VE2FBC9P-9S010 F21 3 m VE2FBC9P-9S030 F22 5 m VE2FBC9P-9S050 F23 Interbus-S (9 pin, male) D-Sub Wireable VE2FBC9P-00000 F24 Interbus-S (9 pin, female) D-Sub Wireable VE2FBC9S-00000 F25 Interbus-S terminating connector D-Sub – V11340-E03 R9 (9 pin male) Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.17 without notice, the specifications given in this document. Valve islands, VM10 series Short codes for valve island specification Model Description Manual override Short code VM103A11AB213B 2 x 3/2 - 2 x NC - Internal feed valve 3 mm PIF Turn & lock NA3T VM103A11AB313B 2 x 3/2 - 2 x NC - Internal feed valve 3 mm PIF Push only NA3U VM104A11AB213B 2 x 3/2 - 2 x NC - Internal feed valve 4 mm PIF Turn & lock NA4T VM104A11AB313B 2 x 3/2 - 2 x NC - Internal feed valve 4 mm PIF Push only NA4U VM106A11AB213B 2 x 3/2 - 2 x NC - Internal feed valve 6 mm PIF Turn & lock NA6T VM106A11AB313B 2 x 3/2 - 2 x NC - Internal feed valve 6 mm PIF Push only NA6U VM107A11AB213B 2 x 3/2 - 2 x NC - Internal feed valve no PIF Turn & lock NAZT VM107A11AB313B 2 x 3/2 - 2 x NC - Internal feed valve no PIF Push only NAZU VM103A22AB213B 2 x 3/2 - 2 x NC - External feed valve 3 mm PIF Turn & lock ND3T VM103A22AB313B 2 x 3/2 - 2 x NC - External feed valve 3 mm PIF Push only ND3U VM104A22AB213B 2 x 3/2 - 2 x NC - External feed valve 4 mm PIF Turn & lock ND4T VM104A22AB313B 2 x 3/2 - 2 x NC - External feed valve 4 mm PIF Push only ND4U VM106A22AB213B 2 x 3/2 - 2 x NC - External feed valve 6 mm PIF Turn & lock ND6T VM106A22AB313B 2 x 3/2 - 2 x NC - External feed valve 6 mm PIF Push only ND6U VM107A22AB213B 2 x 3/2 - 2 x NC - External feed valve no PIF Turn & lock NDZT VM107A22AB313B 2 x 3/2 - 2 x NC - External feed valve no PIF Push only NDZU VM103B11AB213B 2 x 3/2 - 2 x NO - Internal feed valve 3 mm PIF Turn & lock NB3T VM103B11AB313B 2 x 3/2 - 2 x NO - Internal feed valve 3 mm PIF Push only NB3U VM104B11AB213B 2 x 3/2 - 2 x NO - Internal feed valve 4 mm PIF Turn & lock NB4T VM104B11AB313B 2 x 3/2 - 2 x NO - Internal feed valve 4 mm PIF Push only NB4U VM106B11AB213B 2 x 3/2 - 2 x NO - Internal feed valve 6 mm PIF Turn & lock NB6T VM106B11AB313B 2 x 3/2 - 2 x NO - Internal feed valve 6 mm PIF Push only NB6U VM107B11AB213B 2 x 3/2 - 2 x NO - Internal feed valve no PIF Turn & lock NBZT VM107B11AB313B 2 x 3/2 - 2 x NO - Internal feed valve no PIF Push only NBZU VM103B22AB213B 2 x 3/2 - 2 x NO - External feed valve 3 mm PIF Turn & lock NE3T VM103B22AB313B 2 x 3/2 - 2 x NO - External feed valve 3 mm PIF Push only NE3U VM104B22AB213B 2 x 3/2 - 2 x NO - External feed valve 4 mm PIF Turn & lock NE4T VM104B22AB313B 2 x 3/2 - 2 x NO - External feed valve 4 mm PIF Push only NE4U VM106B22AB213B 2 x 3/2 - 2 x NO - External feed valve 6 mm PIF Turn & lock NE6T VM106B22AB313B 2 x 3/2 - 2 x NO - External feed valve 6 mm PIF Push only NE6U VM107B22AB213B 2 x 3/2 - 2 x NO - External feed valve no PIF Turn & lock NEZT VM107B22AB313B 2 x 3/2 - 2 x NO - External feed valve no PIF Push only NEZU VM103C11AB213B 2 x 3/2 - 1 x NC + 1 x NO - Internal feed valve 3 mm PIF Turn & lock NC3T VM103C11AB313B 2 x 3/2 - 1 x NC + 1 x NO - Internal feed valve 3 mm PIF Push only NC3U VM104C11AB213B 2 x 3/2 - 1 x NC + 1 x NO - Internal feed valve 4 mm PIF Turn & lock NC4T VM104C11AB313B 2 x 3/2 - 1 x NC + 1 x NO - Internal feed valve 4 mm PIF Push only NC4U VM106C11AB213B 2 x 3/2 - 1 x NC + 1 x NO - Internal feed valve 6 mm PIF Turn & lock NC6T VM106C11AB313B 2 x 3/2 - 1 x NC + 1 x NO - Internal feed valve 6 mm PIF Push only NC6U VM107C11AB213B 2 x 3/2 - 1 x NC + 1 x NO - Internal feed valve no PIF Turn & lock NCZT VM107C11AB313B 2 x 3/2 - 1 x NC + 1 x NO - Internal feed valve no PIF Push only NCZU VM103C22AB213B 2 x 3/2 - 1 x NC + 1 x NO - External feed valve 3 mm PIF Turn & lock NF3T VM103C22AB313B 2 x 3/2 - 1 x NC + 1 x NO - External feed valve 3 mm PIF Push only NF3U VM104C22AB213B 2 x 3/2 - 1 x NC + 1 x NO - External feed valve 4 mm PIF Turn & lock NF4T VM104C22AB313B 2 x 3/2 - 1 x NC + 1 x NO - External feed valve 4 mm PIF Push only NF4U VM106C22AB213B 2 x 3/2 - 1 x NC + 1 x NO - External feed valve 6 mm PIF Turn & lock NF6T VM106C22AB313B 2 x 3/2 - 1 x NC + 1 x NO - External feed valve 6 mm PIF Push only NF6U VM107C22AB213B 2 x 3/2 - 1 x NC + 1 x NO - External feed valve no PIF Turn & lock NFZT VM107C22AB313B 2 x 3/2 - 1 x NC + 1 x NO - External feed valve no PIF Push only NFZU VM10AC11AB213B 2 X 3/2 - 1 X N/C + 1 X N/O - Internal feed valve 1/8" PIF Turn & lock NCAT VM103517AB213B 5/2 Solenoid Spring - Internal feed valve 3mm PIF Turn & lock NG3T VM103517AB313B 5/2 Solenoid Spring - Internal feed valve 3mm PIF Push only NG3U VM104517AB213B 5/2 Solenoid Spring - Internal feed valve 4mm PIF Turn & lock NG4T VM104517AB313B 5/2 Solenoid Spring - Internal feed valve 4mm PIF Push only NG4U VM106517AB213B 5/2 Solenoid Spring - Internal feed valve 6mm PIF Turn & lock NG6T VM106517AB313B 5/2 Solenoid Spring - Internal feed valve 6mm PIF Push only NG6U VM107517AB213B 5/2 Solenoid Spring - Internal feed valve No PIF Turn & lock NGZT VM107517AB313B 5/2 Solenoid Spring - Internal feed valve No PIF Push only NGZU VM103527AB213B 5/2 Solenoid Spring - External feed valve 3mm PIF Turn & lock NH3T VM103527AB313B 5/2 Solenoid Spring - External feed valve 3mm PIF Push only NH3U VM104527AB213B 5/2 Solenoid Spring - External feed valve 4mm PIF Turn & lock NH4T VM104527AB313B 5/2 Solenoid Spring - External feed valve 4mm PIF Push only NH4U VM106527AB213B 5/2 Solenoid Spring - External feed valve 6mm PIF Turn & lock NH6T VM106527AB313B 5/2 Solenoid Spring - External feed valve 6mm PIF Push only NH6U VM107527AB213B 5/2 Solenoid Spring - External feed valve No PIF Turn & lock NHZT VM107527AB313B 5/2 Solenoid Spring - External feed valve No PIF Push only NHZU Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.18 without notice, the specifications given in this document. Valve islands, VM10 series Short codes for valve island specification Model Description Manual override Short code VM103511AB213B 5/2 Solenoid Solenoid - Internal feed valve 3 mm PIF Turn & lock NJ3T VM103511AB313B 5/2 Solenoid Solenoid - Internal feed valve 3 mm PIF Push only NJ3U VM104511AB213B 5/2 Solenoid Solenoid - Internal feed valve 4 mm PIF Turn & lock NJ4T VM104511AB313B 5/2 Solenoid Solenoid - Internal feed valve 4 mm PIF Push only NJ4U VM106511AB213B 5/2 Solenoid Solenoid - Internal feed valve 6 mm PIF Turn & lock NJ6T VM106511AB313B 5/2 Solenoid Solenoid - Internal feed valve 6 mm PIF Push only NJ6U VM107511AB213B 5/2 Solenoid Solenoid - Internal feed valve No PIF Turn & lock NJZT VM107511AB313B 5/2 Solenoid Solenoid - Internal feed valve No PIF Push only NJZU VM103522AB213B 5/2 Solenoid Solenoid - External feed valve 3 mm PIF Turn & lock NK3T VM103522AB313B 5/2 Solenoid Solenoid - External feed valve 3 mm PIF Push only NK3U VM104522AB213B 5/2 Solenoid Solenoid - External feed valve 4 mm PIF Turn & lock NK4T VM104522AB313B 5/2 Solenoid Solenoid - External feed valve 4 mm PIF Push only NK4U VM106522AB213B 5/2 Solenoid Solenoid - External feed valve 6 mm PIF Turn & lock NK6T VM106522AB313B 5/2 Solenoid Solenoid - External feed valve 6 mm PIF Push only NK6U VM107522AB213B 5/2 Solenoid Solenoid - External feed valve No PIF Turn & lock NKZT VM107522AB313B 5/2 Solenoid Solenoid - External feed valve No PIF Push only NKZU VM103611AB213B 5/3 APB Solenoid Solenoid - Internal feed valve 3 mm PIF Turn & lock NL3T VM103611AB313B 5/3 APB Solenoid Solenoid - Internal feed valve 3 mm PIF Push only NL3U VM104611AB213B 5/3 APB Solenoid Solenoid - Internal feed valve 4 mm PIF Turn & lock NL4T VM104611AB313B 5/3 APB Solenoid Solenoid - Internal feed valve 4 mm PIF Push only NL4U VM106611AB213B 5/3 APB Solenoid Solenoid - Internal feed valve 6 mm PIF Turn & lock NL6T VM106611AB313B 5/3 APB Solenoid Solenoid - Internal feed valve 6 mm PIF Push only NL6U VM107611AB213B 5/3 APB Solenoid Solenoid - Internal feed valve No PIF Turn & lock NLZT VM107611AB313B 5/3 APB Solenoid Solenoid - Internal feed valve No PIF Push only NLZU VM103622AB213B 5/3 APB Solenoid Solenoid - External feed valve 3 mm PIF Turn & lock NM3T VM103622AB313B 5/3 APB Solenoid Solenoid - External feed valve 3 mm PIF Push only NM3U VM104622AB213B 5/3 APB Solenoid Solenoid - External feed valve 4 mm PIF Turn & lock NM4T VM104622AB313B 5/3 APB Solenoid Solenoid - External feed valve 4 mm PIF Push only NM4U VM106622AB213B 5/3 APB Solenoid Solenoid - External feed valve 6 mm PIF Turn & lock NM6T VM106622AB313B 5/3 APB Solenoid Solenoid - External feed valve 6 mm PIF Push only NM6U VM107622AB213B 5/3 APB Solenoid Solenoid - External feed valve No PIF Turn & lock NMZT VM107622AB313B 5/3 APB Solenoid Solenoid - External feed valve No PIF Push only NMZU End plates Model Description Short code VM106517AQ010Y End plate kit - feed both ends 10 mm F100 VM106517AQ0108 End plate kit - feed both ends 8 mm F800 VM106517AQ011Y End plate kit - feed left, right blocked 10 mm L100 VM106517AQ0118 End plate kit - feed left, right blocked 8 mm L800 VM106517AQ012Y End plate kit - feed right, left blocked 10 mm R100 VM106517AQ0128 End plate kit - feed right, left blocked 8 mm R800 VM106517AQ0131 End plate kit - feed both ends no PIF FP00 VM106517AQ0132 End plate kit - feed left, right blocked no PIF RP00 VM106517AQ0133 End plate kit - feed right, left blocked no PIF LP00 Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.19 without notice, the specifications given in this document. Valve islands, VM10 series Valve island specification Valve island specification form VIP/ ............................................................... Company name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contact name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel no. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fax no . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-mail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the short order codes provided complete the build model below. One valve island per sheet only Unit ID No. . . . . . . . . . . . . . . . . . . . . . . . . . Norgren to specify No. of units required Valve range:VM10 End plate code Valve codes Connection options - select one only Individually 25 pin IP65 44 pin IP65 Interbus-S Profibus – DP Profibus – DP DeviceNet DeviceNet with wired D-sub connector D-sub connector 8, 10, 12 & 16 8, 10, 12 & 16 9 pin (IP40) 8, 10, 12 & 16 interlocks 2 ... 20 stations 4, 6, 8, 10 & 12 10, 12 & 16 stations stations stations 8, 10, 12 & 16 stations stations M12 (IP65) stations Accessories Short code Qty per island CANopen CANopen with AB RIO AS interface 8, 10, 12 & 16 interlocks 8, 10, 12 & 16 4, 6 & 8 stations 8, 10, 12 & 16 stations stations stations Power supply options Standard: 24 V d.c. negative common (Multipole & Fieldbus) Select one only Multipole 24 V d.c. positive common Our policy is one of continued research and development. We therefore reserve the right to amend, 8/07 N/en 5.4.115.20 without notice, the specifications given in this document.
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the VM10622B313B have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods