ASTEC DS1200-3
Specifications
Adjustment Range
+/-10% through PMBus only
Efficiency
> 91% typ at 50% load
Hold up Time
20 mSec min.
Input Range (1000W)
90-264 VAC
Input Range (1200W)
180-264 VAC
Input Voltage
90 V to 264 V
Inrush Current
55A max
Main DC Voltage (High Line)
+12 V @ 100 A
Main DC Voltage (Low Line)
+12 V @ 81.6 A
Operating Temperature
-10°C to +50°C
Output Voltage
12 V
Outputs
0, Single
Over Current
Fold back then latch off if over 1 sec
Over Voltage
13.2 - 14.4 VDC main; 3.76 - 4.3 VDC Standby
Overall Regulation
+/-5% both main and standby
Power Factor
0.99 typ
Size (L x W x H)
11.000" x 3.200" x 1.570"
Standby
3.3 V @ 6 A or 5.0 V @ 4 A
Total Max Current
100 A
Total Max Power
1,200 W
Features
- +12Vdc Output
- +3.3 or 5.0 Vdc stand-by
- Active AC Inrush Control
- Active current sharing
- Active Power Factor Correction
- Built-in "Smart" fan
- EEPROM for FRU data
- EN61000-3-2 harmonic compliance
- Full Digital Control
- High Density 21.71 Watts/cu-in
- Hot-plug operation
- INTEL, SSI std. logic timing
- Internal OR'ing FET's
- N+1 Redundant
- No Minimum load required
- PMBus compliant
- Standard 1U x 2U form factor
Datasheet
Extracted Text
Embedded Power for Business-Critical Continuity Rev. 03.15.11_22 DS1200 1 of 4 DS1200 1200 Watts Distributed Power System Distributed Power Bulk Front-End Total Output Power: 1200 Watts +3.3 Vdc Stand-by Output Wide Range Input Voltage: 90 - 264 Vac Electrical Specifications Input Special Features Input ra nge: 180 - 264 (1200 W) 90 - 264 (1000 W) • Active power factor correction Frequency: 47-63 Hz, single phase AC • EN61000-3-2 harmonic compliance • Active AC inrush control Inrush current: 40 Apk maximum inrush current • 1U X 2U form factor Efficiency: > 91% typical at high line 50% load 3 • 21.71 W / in Conducted EMI: FCC Subpart J EN55022 Class B • +12 Vdc Output Radiated EMI: FCC Subpart J EN55022 Class B • +3.3 Vdc stand-by (5 V standby - consult factory) Power factor: 0.99 typical • No minimum load required Leakage current: 1.40 mA @ 240 VAC • Hot plug operation Hold up time: 12 ms minimum • N + 1 redundant • Internal OR’ing fets Output • Active current sharing Main DC voltage: +12 V @ 100 A (high line) (10 - 100% load) +12 V @ 81.6 A (low line) • Built-in cooling fan Stand-By: +3.3 Vsb @ 6 A (5 V @ 4 A available) (40 mm x 28 mm) 2 2 Adjustment range: ±5% on +12V only using I C • I C communication interface bus • PMBus compliant Regulation: +12 Vdc; +5% / -5% • EERPOM for FRU data +3.3 Vsb; +5% / -5% • Red/green bi-color LED status Over current: +12 Vdc; latches off if overcurrent lasts over 1 second, • Internal fan speed control otherwise it is auto recovery (See Table 1 next page) +3.3 Vsb, 9 A • Fan Fail Tach Output Signal max (hiccup mode) • INTEL, SSI Std. logic timing Over voltage: +12 Vdc; 13.2 - 14.4 Vdc • INTEL, SSI Std. FRU data format +3.3 Vsb; 3.76 - 4.30 Vdc • Full digital control Under voltage: +12 Vdc; 9 - 10.8 V (latch off) • Two year warranty Turn-on delay: 2 second max, 5 - 50 mS, monotonic rise Main output rise time: 5 - 50 mS, monotonic rise Safety • UL/cUL 60950 (UL Recognized) • NEMKO+ CB Report EN60950 • EN60950 • CE Mark • China CCC Embedded Power for Business-Critical Continuity Rev. 03.15.11_22 Logic Control DS1200 2 of 4 PS_SEATED (A4): TTL logic LOW if power supply is seated into system connector. This is a short pin. A logic HIGH if the PSU is removed PWR GOOD (C3): Active TTL high when output is within regulation limits. AC OK (B1): A low logic level if the input voltage is within allowable limits. A TTL logic HIGH level, and a 5mS early warning signal before 12.0 V DC output loss of regulation. PS_INHIBIT/PS_KILL (B4): When left open power supply operation will be inhibited. When the power supply is inserted into the system, this pin will be pull low by the system and turn the power supply on only after all other power supply pins have seated. PS ON (A1): The output will be enabled when this signal is pulled low, below 0.8 V outputs disabled when pin is driven high or left open. Environmental Specifications Operating temperature: -10° to 50 °C Storage temperature: -40 °C to +85 °C Altitude, operating: 10,000 ft Electromagnetic susceptibility / Input transients: -EN61000-3-2, -3-3 -EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level -EN55024:1998 RoHS & lead-free compliant: No tantalum caps. Humidity: 20 to 90% RH, non-condensing Shock and vibration specificatons: Complies with Astec Std. Specifications, Q3205 MTBF (Demonstrated): 500K Hrs at full load, 40 °C Ordering Information Nominal Output Set Point Total Minimum Maximum Output Ripple Model Number Over Current Stand-by Air Flow Voltage Set Point Tolerance Regulation Current Current P/P DS1200-3 12.0 Vdc ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 3.3 V @ 6 A STD DS1200-3-002 12.0 Vdc ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 5.0 V @ 4 A STD † DS1200-3-003** 12.0 Vdc ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 3.3 V @ 6 A REV † DS1200-3-004** 12.0 Vdc ±0.2% ±5% 0 A 100 A 120 mV 118 A - 147.6 A* 5.0 V @ 4 A REV *Over current latches off if overcurrent lasts over 1 seconds, otherwise it is auto recovery. **Release in April 2010 † Derating may apply. STANDARD AIR DERATING Reverse Air Derating 1400 4.5 Output Power (W) 1400 4 1200 1140W @ 25 °C 1200 3.5 1025W @ 50 °C 1000 1000 3 800 800 2.5 760W @ 70 °C Output Power 90 - 179 Vac 600 180 - 264 Vac 5 Vsb 2 600 400 1.5 200 400 1 0 020255070 200 0.5 Ambient Temperature (°C) 0 0 05 10 15 20 25 30 35 40 45 50 55 60 65 70 75 AMBIENT DEG C POWER WATTS 5Vsb CURRENT AMPS Embedded Power for Business-Critical Continuity Rev. 03.15.11_22 DS1200 Mechanical Drawing 3 of 4 Condition LED Status Stand-by - ON; Main output - OFF; AC PRESENT Blinking green Stand-by - ON; Main output - ON; Solid green Main output OCP, UVP, OVP Blinking Amber FAN_FAULT; OTP; Stand-by OCP/UVP Amber AIRFLOW DIRECTION 279.4 ± 1.0 200.9 7.02 ± 0.80 EMI GASKET - LEIRD 77-018 (3X) (200.9) (3X) EMI GASKET - LEIRD 77-018 LABEL MODEL 30.0 HANDLE LATCH 3.2 8.0 PROGRAMMING WINDOW 275.5 ± 0.7 81.3 ± 0.8 200.9 C19 AC-INLET FAN 36 X 36 X 28MM 5.7 ± 0.5 EMI GASKET - LEIRD 77-018 7.6 39.9 ± 0.5 16.1 18.4 ± 0.5 7.2 ± 0.5 PURE ORANGE 1.9 15.3 ± 0.5 WAVE LENGTH: 607 GREEN WAVE LENGTH: 565 68.8 6.0 (2X) 1.5 X 45° CHAMPER 9.0 RECOMMENDED KEY HEIGHT IS 2.5MM MAX. Embedded Power for Business-Critical Continuity Rev. 03.15.11_22 DS1200 Americas DC Output Connector Pinout Assignment 4 of 4 5810 Van Allen Way Male connector as viewed from the rear of the supply: Carlsbad, CA 92008 USA D1 D2 D3 D4 D5 D6 Telephone: +1 760 930 4600 C1 C2 C3 C4 C5 C6 PB1 PB2 PB3 PB4 PB5 PB6 Facsimile: +1 760 930 0698 B1 B2 B3 B4 B5 B6 A1 A2 A3 A4 A5 A6 Europe (UK) Waterfront Business Park P1 - Power Supply Side Pin Assignments Merry Hill, Dudley 1. FCI Power Blade 51721 series West Midlands, DY5 1LX Pin Signal Name 51721-10002406AA United Kingdom PB 1 Main output return 2. Molex Power Connector Telephone: +44 (0) 1384 842 211 PB 2 Main output return SD-87667 series Facsimile: +44 (0) 1384 843 355 PB 3 Main output return 87667-7002 PB 4 + Main output Asia (HK) PB 5 + Main output Mating Connector (System Side) 14/F, Lu Plaza PB 6 + Main output 1. FCI Power Blade 2 Wing Yip Street A1 PS_ON 51741-10002406CC Kwun Tong, Kowloon A2 Main output remote sense return Straight Pins Hong Kong A3 Spare Telephone: +852 2176 3333 2. FCI Power Blade A4 PS_SEATED (Power Supply Seated) Facsimile: +852 2176 3888 51761-10002406AALF A5 STAND-BY Right Angle A6 STAND-BY RETURN For global contact, visit: B1 AC_OK (AC Input Present) www.Emerson.com/EmbeddedPower B2 Main output remote sense B3 Main output current share techsupport.embeddedpower B4 PS_INHIBIT / PS_Kill @emerson.com B5 STAND-BY While every precaution has been taken to ensure B6 STAND-BY RETURN accuracy and completeness in this literature, Emerson 2 C1 SDA (IC Data Signal) Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this 2 C2 SCL (IC Clock Signal)* information or for any errors or omissions. C3 POWER GOOD C4 Spare Emerson Network Power. C5 STAND-BY The global leader in enabling C6 STAND-BY RETURN business-critical continuity. 2 D1 A0 (IC Address BIT 0 Signal) 2 D2 A1 (IC Address BIT 1 Signal) AC Power D3 S_INT (Alarm) Connectivity D4 STAND-BY RMT SENSE D5 STAND-BY DC Power D6 STAND-BY RETURN Embedded Computing 2 *Supports I C standard mode (100 kHz) only Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2011 Emerson Electric Co. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Emerson Network Power : DS1200-3-002 DS1200-3-003 DS1200-3-005 DS1200-3
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the DS1200-3 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods