Description

UPG CIRCUIT BREAKER, ONE TOGGLE HANDLE PER UNIT, SINGLE POLE, AUX. SWITCH, .187 QUICK CONNECT TERMINALS, .100 AMMPS

Part Number

UPG1-1REC5-60-101-21

Price

Request Quote

Manufacturer

AIRPAX

Lead Time

Request Quote

Category

PRODUCTS - U

Features

Datasheet

pdf file

APG1-REC5-60-102-30-datasheet-1849378921.pdf

1620 KiB

Extracted Text

APG/UPG/IPG Series Magnetic Circuit Protectors Introduction | 120 Single & Multi-Pole | 121 Rocker, Sealed Toggle | 124 Configurations | 129 Operating Characteristics | 131 Delay Curves | 132 Specifications | 136 Decision Tables | 138 APG/UPG/IPG APG/UPG/IPG Series Hydraulic Magnetic Circuit Protectors INTRODUCTION The APG/UPG magnetic circuit protector provides low-cost toggle or rocker actuated handles and caps are available in a power switching, reliable circuit protection and accurate circuit variety of attractive colors. control in one complete package. It is intended for use in data processing and broadcast equipment, vending and amusement Multi-pole circuit protectors can be furnished with either single machines, military and marine applications, and wherever or multiple actuators. In addition, a unique sealed, single handle precision operation is required. toggle version for harsh or military environments is available in single or multi-pole configurations. Designed using a current sensitive hydraulic magnetic principle, the APG/UPG adapts itself to many applications and The UPG circuit protector is recognized under UL Standard 1077, environments. Temperature compensations which affect fuses file numbers E66410 and E33504 as a supplementary protector. and other thermal devices are not a concern. Nuisance tripping It is also certified by CSA under CSA STD. C22.2–No. 235, file is minimized. number LR26229 as a supplementary protector. The APG is qualified to MIL-PRF-55629. The APG/UPG is available in a wide variety of configurations with a choice of delays and ratings. In addition, it is available in either APG/UPG circuit protectors are available in one through four DC, 50/60Hz or 400Hz versions. pole assemblies with a variety of pole arrangements, terminal styles, and accessories to meet your specifications, including Available in single or multi-pole variations, the APG/UPG comes APG/UPG adapter plate option to allow mounting in APL/UPL with a variety of actuators. To enhance front-panel aesthetics, cutout. 120 APG/UPG/IPG Series - Introduction http://airpax.sensata.com/ APG/UPG SINGLE POLE CIRCUIT PROTECTORS APG/UPG/IPG Series Single Pole, Toggle 1.640 .69 [ ] [ ] 41.66 17.53 MAIN TeRMINAl TYPeS Amp 8-32 M4 10-32 M5 Push-On Rating Screw Screw Screw Screw .1 to 30 X X X .13 30.1 to 50 X X [3.30] Single Pole APG 6-1* [ ] .187 4.75 DEEP (TYP.) M3 1S0. THD. OPTIONAL .23 .590 DIA. [ ] MAX. 5.84 [ ] 15.00 2.00 OFF [50.80] 1.53 1.66 [38.86] [42.16] 1.22 [ ] 31.00 .168 [ ] 4.27 .75 [19.05] Single Pole, Mounting Detail +.010 -.000 2X .625 +.25 -.00 15.87 Notes: Tolerance ±.015 [.38] unless noted. 1.660 Dimensions in Brackets [ ] 1.050 42.16 [26.67] [ ] are millimeters. * * Allows mounting in APL/UPL cutout. 2X .156 [ ] 3.96 http://airpax.sensata.com/ APG/UPG/IPG Series - Single Pole 121 APG/UPG/IPG TwO POLE PROTECTORS An assembly consisting of two single pole units, having their trip mechanisms internally coupled, and with a single toggle handle, forms the APG/UPG-11. It is also possible to provide a handle per pole, which is referred to as UPGH11. Individual poles may differ in ratings, delays and internal connections. An auxiliary switch may be included in either or both poles if they are of the series trip type. Screw-type terminals can be provided, in which case the designation would be APG/UPG-66. Two Pole UPG11 UPGH11 [ ] .590 DIA. .187 4.75 DEEP (TYP.) MAX. M3 1S0. THD. OPTIONAL [15.00] 1.640 .69 [41.66] [17.53] 2.00 [50.80] OFF OFF OFF 1.66 [42.16] 1.22 [ ] 31.00 .13 .75 .168 [3.30] [ ] [19.05] 4.27 1.515 MAX. [ ] 38.48 1.515 MAX. (Optional, handle [ ] 38.48 may be in pole 1 instead of pole 2) UPG11 UPGH11 .156 [3.96] (2 PER POLE) 1.660 +.010 [42.16] -.000 1.050 .625 [26.67] +.25 -.00 15.88 ( 1 PER POLE) .750 .750 [ ] [19.05] 19.05 Two Pole Two Pole* Panel Mounting Detail: Tolerance ±.005 [.13] unless noted. Note: Tolerance ± .015 [.38] unless noted. Dimensions in Brackets [ ] are millimeters. * See single pole mounting detail for hole sizes and locations. 122 APG/UPG/IPG Series - Multi-Pole http://airpax.sensata.com/ THREE POLE AND FOUR POLE PROTECTORS The three pole structure consists of three single pole units Protector poles are numbered consecutively when viewed assembled with an internal mechanical interlock which from the terminal side, with the ON position up, starting with actuates all units simultaneously. A single toggle handle Pole #1 on the left side and proceeding to the right. operates all three poles, or a handle per pole is available. 1.640 .69 The four pole structure consists of four single pole units [41.66] [17.53] assembled with an internal mechanical interlock which actuates all units simultaneously. A double toggle handle OFF OFF OFF OFF operates all four poles, or a handle per pole is available. The individual poles need not have identical characteristics and any series trip pole may have an auxiliary switch. If screw- type terminals are required, the breaker designation will be .13 .750 .750 [3.30] 2.265 MAX. [19.05] [19.05] APG/UPG-666 for a three pole version and APG/UPG-6666 for [ ] 57.53 2.265 MAX. a four pole version. [ ] 57.53 1.640 .69 1.640 .69 1.640 .69 [ ] [ ] [41.66] [17.53] 41.66 17.53 [ ] [ ] 41.66 17.53 .750 .750 .750 .750 1.640 .69 [ ] [ ] [ ] 19.05 [19.05] 19.05 19.05 Three Pole [41.66] [17.53] Three Pole 1.640 .69 [41.66] [17.53] 1.640 .69 1.640 .69 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF [41.66] [17.53] [41.66] [17.53] OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF .13 .750 .750 .13 .13 [3.30] 2.265 MAX. .750 [ ].750 [ ] .750 .750 19.05 19.05 [3.30] [3.30] 2.265 MAX. [ ] [ ] 2.265 MAX. [ ] [19.05] [19.05] 19.05 19.05 57.53 2.265 MAX. .13 .750 .750 [ ] [57.53] [3.30] 57.53 2.265 MAX. [ 2.265 MAX. ] 57.53 .13 2.265 MAX. [ ] [19.05] 19.05 .750 .750 [ ] [3.30] [57.53] 57.53 [ ] 57.53 2.265 MAX. 2.265 MAX. [ ] [19.05] .13 .13 19.05 UPG 111 .750 .750 .750 .750 UPGH 111 [3.30] [3.30] [ ] [57.53] 57.53 2.265 MAX. 2.265 MAX. 2.265 MAX. [19.05] [19.05] [19.05] [19.05] [57.53] [ ] [ ] 57.53 57.53 2.265 MAX. 2.265 MAX. .750 .750 .750 .750 [57.53] [57.53] [19.05] [ ] [19.05] [19.05] 19.05 .750 .750 .750 .750 .750 .750 .750 .750 Mounting Mounting [ ] [ ] [ ] [19.05] [ ] 19.05 .750 [19.05 .750 ] [19.05] [19.05] .750 19.05 .750 19.05 19.05 * See single pole mounting detail [ ] [19.05] [19.05] 19.05 [19.05] Detail Detail .750 .750 .750 .750 [ for ]hole sizes and locations. [19.05] [19.05] 19.05 [19.05] .750 .750 .750 .750 .750 .750 .750 .750 [ ] [ ] [ ] [ ] [19.05] [19.05] [19.05] [19.05] 19.05 19.05 19.05 19.05 OFF OFF OFF OFF OFF OFF Three Pole* Three Pole* .750 .750 .750 .750 [19.05] [ ] [ ] [ ] 19.05 19.05 19.05 3.015 MAX. 3.015 [ ] 76.58 MAX. [ ] 76.58 OFF OFF OFF OFF OFF OFF Four Pole Four Pole OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF .750 .750 .750 .750 .750 .750 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF [ ] 19.05 [19.05] [ ] [ ] 19.05 19.05 [19.05] [19.05] .750 .750 .750 .750 [ ] 19.05 [19.05] [19.05] [19.05] 3.015 MAX. 3.015 .750 .750 .750 .750 [76.58] [19.05] [ ] [ MAX. ] [ ] 19.05 19.05 19.05 3.015 .750 .750 .750 .750 .750 [76.58] .750 [19.05] .750 .750 .750 .750 .750 .750 [ ] MAX. [19.05] 19.05 [19.05] .750 .750 3.015 3.015 [ ] [19.05] 19.05 .750 .750 .750 .750 .750 .750 [ ] [19.05] [ ] [19.05] [19.05] [19.05] [76.58] 19.05 19.05 3.015 [19.05] 3.015 [19.05] MAX. MAX. [ ] [ ] [ ] [ ] [ ] [ ] 19.05 19.05 19.05 19.05 19.05 3.015 19.05 3.015 3.015 MAX. MAX. [76.58] [76.58] 3.015 3.015 MAX. MAX. MAX. 3.015 3.015 [ ] [76.58] 76.58 MAX. MAX. [76.58] [76.58] [76.58] .750 .750 .750 .750 MAX. MAX. .750 .750 APG/UPG [ only ] [ ] [ ] [76.58] 19.05 19.05 [19.05] 76.58 [19.05[] [ ] ] [ ] [ ] 76.58 19.05 19.05 76.58 APGH/UPGH only .750 .750 .750 .750 .750 .750 [19.05] [ ] 19.05 [19.05] [19.05] [19.05] [19.05] .750 .750 .750 .750 .750 .750 [ ] [ ] 19.05 19.05 [19.05] [19.05] [19.05] [ ] 19.05 .750 .750 .750 .750 .750 .750 .750.750 .750 .750 .750 .750 .750 .750 .750 .750 .750 .750 .750 .750 .750 .750 .750 .750 Mounting Mounting [19.05] [ ] [ ] [19.05] [ ] [ ] [ 19.05 ] [ 19.05 ] 19.05 [19.05 19.05 ] [19.05] [19.05] [19.05] [19.05] [19.05] [19.05] [19.05] [19.05] 19.05 19.05 [19.05] [ ] [ ] [19.05] [ ] [ ] 19.05 19.05 [19.05] 19.05 19.05 Detail Detail Four Pole* Four Pole* http://airpax.sensata.com/ APG/UPG/IPG Series - Multi-Pole 123 APG/UPG/IPG APGHX / UPGHX DIMeNSION “A” Rocker actuated APGHX/UPGHX provides one rocker handle for Number of Poles Dimensions “A” each pole of a multi-pole circuit protector. 2 1.510 ± .005 [38.35 ± .13] 3 2.265 ± .005 [57.53 ± .13] Two Pole Three Pole 1.515 2.265 .23 MAX. MAX. [5.84] [38.48] [57.53] 2.00 1.22 [50.80] [31.00] 1.66 ON ON ON ON [42.16] ON 1.53 [38.86] 2.481 OFF OFF OFF OFF OFF [63.02] 2.59 [65.79] .540 [13.72] .340 1.640 [ ] [8.64] 41.66 HANDLE WIDTH .440 .75 .75 .75 [11.18] [ ] 19.05 [ ] [ ] 19.05 19.05 Panel Mounting Detail: Tolerance Two Pole Three Pole ±.005 [.13] unless noted. 2.265 1.510 [ ] [ ] 57.53 38.35 1.260 1.660 1.660 1.260 [ ] [ ] [ ] [42.16] 32.00 42.16 32.00 .200 .200 .750 .750 .750 6X .156 4X .156 [ ] [5.08] 5.08 [19.05] [19.05] [19.05] [ ] [ ] 3.96 3.96 124 APG/UPG/IPG Series - Rocker http://airpax.sensata.com/ APGX / UPGX Rocker actuated APGX / UPGX provides one rocker handle per circuit protector. Single Pole Two Pole 1.515 .23 .75 MAX. [5.84] [19.05] [38.48] 2.00 1.22 [50.80] [31.00] 2.59 [ ] ON ON 65.79 1.53 1.66 [38.86] [ ] 42.16 OFF OFF 2.481 [63.02] .540 1.640 [13.72] [ ] 41.66 .440 [11.18] HANDLE WIDTH (Optional, handle may be in pole 2 instead of pole 1) Three Pole One, Two & Three Pole .750 [ ] 2.265 19.05 MAX. [ ] 57.53 ON 1.660 1.260 OFF [42.16] [ ] 32.00 Panel Mounting Detail: Tolerance ±.005 [.13] .200 2X .156 unless noted. [ ] 5.08 [ ] 3.96 Note: Tolerance ± .015 [.38] unless noted. Dimensions in Brackets [ ] are millimeters. http://airpax.sensata.com/ APG/UPG/IPG Series - Rocker 125 APG/UPG/IPG .625 .750 BAT HANDLE / PANEL SEAL (APGN / UPGN) [ ] 15.88 .130 19.05 .230 The APGN is designated to provide circuit protection in harsh and [ ] [5.84] 3.30 military environments. Waterproof panel integrity is provided by an “O” ring bushing seal and silicon rubber gland within the bushing/ handle assembly. Single, two or three pole versions are available ON 1.530 [ ] with two and three pole versions featuring a single operating 38.86 handle and mounting bushing. OFF LOCKWASHER Two Pole Three Pole Single Pole 1.220 [31.00] .656 2.000 [16.66] [50.80] 1.515 2.265 .750 MAX. [ ] MAX. 19.05 [38.48] [57.53] (Optional handle may be in pole 2 instead of pole 1) Single Pole Two Pole* Three Pole* .750 .750 .750 .156 [19.05] [ ] [ ] 19.05 19.05 [3.96] .656 .515 [16.66] [ ] 13.08 Panel Mounting Detail: Mounting Optional Handle detail tolerance ±.005 [.13] unless noted. *See single pole mounting detail for hole sizes and locations. 126 APG/UPG/IPG Series - Bat Handle, Panel Seal http://airpax.sensata.com/ Standard Handle Location TOGGLE HANDLES (APG/UPG) (Applies to 2 Pole Only) The APG/UPG circuit protector is available with toggle handles in six different col- ors. For attractive panel appearance, color caps are also available. Handles may be specified in black, white, yellow, red, blue and green. For multi-pole units, specify handle per unit or handle per pole. Toggle Handles OFF APG/UPG Color Caps For attractive panel appearance the following color caps are available for use on APG/UPG protectors. Bat Handle/ Panel Seal APGN/UPGN COlOR CAPS Color Order Separately Rocker Red 762 - 300 - 8046 Green 762 - 300 - 8043 ON white 762 - 300 - 8040 OFF Gray 762 - 300 - 8041 Blue 762 - 300 - 8042 Yellow 762 - 300 - 8044 APGX/UPGX Orange 762 - 300 - 8045 Brown 762 - 300 - 8047 Black 762 - 300 - 8048 http://airpax.sensata.com/ APG/UPG/IPG Series - Toggle 127 APG/UPG/IPG IPG MAGNETIC CIRCUIT PROTECTORS 1.640 .690 [41.66] [17.53] The IPG circuit protectors provide the 32º advantages of magnetic “stand alone” protection and compliance with UL, CSA, 32º SEV, VDE and IEC standards. They are UL Recognized per UL STD. 1077 as .250 2.032 supplementary protectors, CSA Certified per [ ] [51.61] 6.35 MAX. CSA C22.2–No. 235 as supplementary protectors, VDE approved and CE compliant to VDE 0642 (EN60934). Additionally, they Two Pole Single Pole conform to the spacing requirements of VDE 0730, 0804, 0805 and 0806, and IEC 950 for use in office machines and data processing .590 MAX. [15.00] equipment. IPG circuit protectors have current ratings from .020 to 50 amperes, 250Vac, 65Vdc, 2.000 1.660 [50.80] [ ] 42.16 and an auxiliary switch is available with 1.220 [30.99] either gold or silver contacts. They feature one through four pole configurations, with .168 .750 [ ] .750 4.27 one handle per pole. A choice of handle [ ] 19.05 [ ] 19.05 1.515 actuation colors, terminals and hardware are [ ] 38.48 MAX. available and international markings are standard. And, with an adapter plate, they will fit in panels cut for Airpax APL and UPL type protectors. Three Pole Four Pole Note: .750 .750 .750 .750 .750 [19.05] [19.05] [ ] [ ] Main terminals are stationary male push-on type .250 [6.35] [19.05] 19.05 19.05 2.265 wide x .031 [.787] thick x .312 [7.92] long or 8-32 x .187 [4.75] 3.015 [57.53] [ ] 76.58 MAX. screw type (≤30A). 10-32 x .187 [4.75] screw type (>30A). MAX. Panel mounting detail: Tolerance ± .005 [.13] unless noted. 1.660 [42.16] 1.050 [26.67] .750 [19.05] 128 APG/UPG/IPG Series - IPG http://airpax.sensata.com/ Series and Switch Only APG/UPG/IPG CONFIGURATIONS .23 .23 Series Trip [5.84] [ ] 5.84 The most popular configuration for magnetic protectors is the series trip where the sensing coil and contacts are in series with the load being protected. The handle position 1.53 1.53 conveniently indicates circuit status. In addition to provid- [ ] 38.86 [38.86] ing conventional overcurrent protection, it’s simultaneously used as an on-off switch. Series Switch Only Shunt and Dual Coil .23 Shunt Trip [ ] 5.84 The shunt trip is designed for controlling two separate loads with one assembly. The control is established by 1.53 providing overload protection for the critical load. When [38.86] 1.38 the current through this load becomes excessive and [35.05] reaches the trip point, the protector will open and remove power from both loads simultaneously. The total current Shunt Dual Coil rating of both loads must not exceed the maximum con- tact rating. Tapped Coil .23 [ ] 5.84 1.53 [ ] 38.86 1.38 [ ] 35.05 Tapped Coil Note: Tolerance ± .015 [.38] unless noted. Dimensions in Brackets [ ] are millimeters. http://airpax.sensata.com/ APG/UPG/IPG Series - Configurations 129 APG/UPG/IPG Relay Trip Relay and Dual Coil This permits the overload sensing coil to be placed in a .23 [5.84] circuit which is electrically isolated from the trip contacts. .61 The coil may be actuated by sensors monitoring pressure, [ ] 15.50 flow, temperature, speed, etc. Other typical applications include crowbar, interlock and emergency/rapid shutdown 1.38 1.53 [ ] 35.05 [ ] 38.86 circuitry. Trip may be accomplished by voltage or current, which must be removed after trip. Dual Coil Relay .23 Auxiliary Switch [ ] 5.84 Relay and Four Terminal This is furnished as an integral part of a series pole in .61 Dual Coil with Screw Terminal single or multi-pole assemblies. Isolated electrically from [ ] 15.50 the protector’s circuit, the switch works in unison with the 1.53 1.38 power contacts and provides indication at a remote location [ ] [ ] 38.86 35.05 of the protector’s on-off status. Auxiliary Switch Voltage Trip Sometimes called “dump circuits” or “panic trip circuits,” .295 .312 [7.49] these units make it possible to open main power contacts [7.92] with lower power inputs from one or more sources. This configuration is becoming increasingly more important for sensitive circuitry and denser packaging in automation systems. Available in series, shunt, or relay configurations. .110 .187 [ ] [2.79] 4.75 -1 REC 4 -1 REC 5 -1 REG 4 -1 REG 5 Quick Connect Quick Connect Terminals Terminals C NO C Series with Auxiliary Switch NC NO All auxiliary switch terminals NC .020[.51] thick Standard auxiliary switch is REC 4. Breaker in OFF position Note: Main terminals are stationary male push-on type .250 [6.35] wide, x .031 [.787] thick, x .312 [7.92] long or 8-32 x [4.75] screw type (≤30A), 10-32 x .187 [4.75] screw type (>30A). Note: Tolerance ± .015 [.38] unless noted.Dimensions in Brackets [ ] are millimeters. 130 APG/UPG/IPG Series - Configurations http://airpax.sensata.com/ APG/UPG/IPG OPERATING CHARACTERISTICS NOMINAl DCR / IMPeDANCe Resistance (ohms) Impedance (ohms) Impedance (ohms) Current DC Delays AC, 50/60Hz Delays AC, 400Hz Delays Ratings (Amps) Dual Coil 600, 61, 62 64, 65, 66 50 59 51, 52, 53 60 69 40, 49 41, 42, 43 51, 52, 53 71, 72, 73 Dual Coil 61, 62 0.05 162 540 460 640 174 419 582 691 1975 1195 0.10 35.4 105 155 150 42.5 103.4 119.0 160 495 284 0.50 1.2 4.2 4.5 5.6 1.9 4 4.1 6.2 22 12 1.0 .236 1.02 1.2 1.41 .41 .955 1.08 1.56 5.01 2.72 5.0 .021 .048 .059 .070 .030 .045 .048 .068 .240 .140 10.0 .0060 .0121 .0140 .0160 .0075 .0105 .0134 .0174 .0520 .0283 15.0 .0040 .0067 .0092 .0100 .0038 .0068 .0070 .0120 .0260 .0140 20.0 .0032 .0047 .0052 .0070 .0024 .0049 .0050 .0069 .0140 .0088 30.0 .0021 .0036 .0036 .0040 .0022 .0032 .0035 .0037 .0079 .0043 50.0 .0020 .0024 .0026 .0023 .0020 .0020 .0025 .0030 .0036 .0028 Notes: DCR and impedance based on 100% rated current applied and stablized a minimum of one hour. Tolerance: .02 amperes to 2.5 amperes, ± 20%; 2.6 amperes to 20 amperes, ± 25%; 21 amperes to 50 amperes, ± 50%. Consult factory for special values and for coil impedance of delays not shown PeRCeNTAGe Of RATeD CURReNT VS TRIP TIMe IN SeCONDS AT +25°C Delay 100% 125% (Note A) 150% 200% 400% 600% 800% 1000% 40 No Trip May Trip .040 Max. .035 Max. .030 Max. .025 Max. .020 Max. .018 Max. 41 No Trip May Trip .5 to 8 .15 to 1.9 .02 to .4 .006 to .25 .004 to .1 .004 to .05 42 No Trip May Trip 5 to 70 2.2 to 25 .40 to 5 .012 to 2 .006 to .2 .006 to .15 49 No Trip .150 Max. .100 Max. .032 Max. .020 Max. .020 Max. .020 Max. .020 Max. 43 & 400 No Trip May Trip 35 to 350 12 to 120 1.5 to 20 .1 to 4 .01 to .250 .009 to .100 50 No Trip May Trip .032 Max. .024 Max. .020 Max. .018 Max. .016 Max. .015 Max. 51 No Trip .5 to 6.5 .3 to 3 .1 to 1.2 .031 to 5 .011 to .25 .004 to .1 .004 to .08 52 No Trip 2 to 60 1.8 to 30 1 to 10 .15 to 2 .04 to 1 .008 to .5 .006 to .1 59 No Trip .100 Max. .070 Max .032 Max. .020 Max. .020 Max. .020 Max. .020 Max. 53 & 500 No Trip 80 to 700 40 to 400 15 to 150 2 to 20 .7 to 10 .1 to 3 .010 to .100 60 No Trip May Trip .040 Max. .035 Max. .030 Max. .025 Max. .020 Max. .018 Max. 61 No Trip .7 to 12 .35 to 7 130 to 3 .030 to 1 .015 to .3 .01 to .15 .008 to .1 62 No Trip 10 to 120 6 to 60 2 to 20 .2 to 3 .02 to 2 .015 to .8 .01 to .25 64 No Trip .7 to 10 .35 to 6 .15 to 3 .05 to .6 .025 to .3 .020 to .22 .015 to .15 65 No Trip 7 to 90 3 to 40 1 to 12 .2 to 3 .08 to 1 .03 to .7 .016 to .3 66 No Trip 50 to 700 30 to 400 10 to 150 1.5 to 20 .4 to 10 .05 to 3 .02 to 2 69 No Trip .120 Max. .100 Max. .050 Max. .022 Max. .017 Max. .017 Max. .017 Max. 600 No Trip 80 to 700 45 to 400 15 to 150 2 to 20 .2 to 4 .025 to 1 .01 to .2 Notes: All trip curves and trip currents are specified with the protector mounted in the normal vertical position at ambient temperature of +25° C. Protectors do not carry current prior to application of overload. A: Ratings above 30 amps may deviate from the above limits by approximately 10% (130% for delay 49). http://airpax.sensata.com/ APG/UPG/IPG Series - Operating Characteristics 131 APG/UPG/IPG DUAl fReQUeNCY (50/60Hz) PeRCeNTAGe Of RATeD CURReNT VS TRIP TIMe IN SeCONDS AT +25°C Delay 100% 135% 150% 200% 400% 600% 800% 1000% 71 No Trip .4 to 14 .2 to 7 .1 to 3 .027 to 1 .015 to .3 .01 to .15 .008 to .1 72 No Trip 7 to 130 3 to 60 1.3 to 20 .085 to 3 .02 to 2 .015 to .8 .01 to .26 73 No Trip 50 to 700 30 to 400 10 to 150 .8 to 20 .14 to 4 .025 to 1 .01 to .26 Notes: All trip curves and trip currents are specified with the protector mounted in the normal vertical position at ambient temperature of +25° C. Protectors do not carry current prior to application of overload. INRUSH PUlSe TOleRANCe Delay Pulse Tolerance Inrush Pulse Tolerance 61, 62 10 times rated current (approx) It can be seen that the 64, 65 and 66 delays have a high inrush 61F, 62F 20 times rated current (approx) capability and for most applications an inertia wheel would not be required. Pulse tolerance is defined as a single pulse of half 64, 65, 66 20 times rated current (approx) sine wave peak current amplitude of 8 milliseconds duration that 64F, 65F, 66F 35 times rated current (approx) will not trip the circuit breaker. Note: These limits do not apply to dual coil and tapped coil units DELAY CURVES (TYP) 50/60Hz Delay Curves (typ) A choice of delays is offered for DC, 50/60Hz, and 400 Hz applications. Delays 40, 50, 60, 49, 59 and 69 provide fast-acting, instantaneous trip and are often used to protect sensitive electronic equipment (not recommended where known inrush exists). Delays 41, 51, 61 and 71 have a short delay for general purpose applications. Delays 42, 52 and 62 are long enough to start certain types of motors and most transformer and capacitor loads. Delays 43, 53 and 63 are long delays for special motor applications at 400Hz DC and 50/60Hz. 10000 10000 1000 1000 DELAY 60 DELAY 61 100 100 10 10 1 1 .1 .1 .01 .01 .001 .001 0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000 125 125 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT 132 APG/UPG/IPG Series - Delay Curves http://airpax.sensata.com/ TIME IN SECONDS MAY TRIP TIME IN SECONDS MAY TRIP 10000 1000 DELAY 65 100 10 1 .1 .01 .001 0 100 150 200 300 400 500 600 700 800 900 1000 135 PERCENT OF RATED CURRENT 10000 10000 1000 1000 DELAY 62 DELAY 66 100 100 10 10 1 1 .1 .1 .01 .01 .001 .001 0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000 125 125 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT 10000 10000 1000 DELAY 64 1000 DELAY 69 100 100 10 10 1 1 .1 .1 .01 .01 .001 .001 0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000 125 125 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT http://airpax.sensata.com/ APG/UPG/IPG Series - Delay Curves 133 TIME IN SECONDS TIME IN SECONDS MAY TRIP MAY TRIP TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS MAY TRIP MAY TRIP MAY TRIP APG/UPG/IPG DC Delay Curves (typ) 10000 1000 DELAY 52 100 10 1 .1 .01 .001 0 100 150 200 300 400 500 600 700 800 900 1000 125 PERCENT OF RATED CURRENT 10000 10000 1000 1000 DELAY 50 DELAY 53 100 100 10 10 1 1 .1 .1 .01 .01 .001 .001 0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000 125 125 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT 10000 10000 1000 DELAY 51 1000 DELAY 59 100 100 10 10 1 1 .1 .1 .01 .01 .001 .001 0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000 125 125 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT 134 APG/UPG/IPG Series - Delay Curves http://airpax.sensata.com/ TIME IN SECONDS TIME IN SECONDS MAY TRIP MAY TRIP TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS MAY TRIP MAY TRIP MAY TRIP 400Hz Delay Curves (typ) 10000 1000 DELAY 42 100 10 1 .1 .01 .001 0 100 150 200 300 400 500 600 700 800 900 1000 125 PERCENT OF RATED CURRENT 10000 10000 1000 1000 DELAY 40 DELAY 43 100 100 10 10 1 1 .1 .1 .01 .01 .001 .001 0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000 125 125 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT 10000 10000 1000 DELAY 41 1000 DELAY 49 100 100 10 10 1 1 .1 .1 .01 .01 .001 .001 0 100 150 200 300 400 500 600 700 800 900 1000 0 100 150 200 300 400 500 600 700 800 900 1000 125 130 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT http://airpax.sensata.com/ APG/UPG/IPG Series - Delay Curves 135 TIME IN SECONDS TIME IN SECONDS MAY TRIP MAY TRIP TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS MAY TRIP MAY TRIP MAY TRIP APG/UPG/IPG Trip free Insulation Resistance will trip open on overload, even when forcibly held in Not less than 100 megohms at 500Vdc. the ON position. Dielectric Strength Trip Indication APG/UPG/IPG protectors withstand 1500 volts, 60Hz for 60 The operating handle moves positively to the OFF seconds between all electrically isolated terminals. Except position on overload. auxiliary switch terminals shall withstand 600 Volts at 60Hz. Ambient Operation endurance APG/UPG protectors operate normally in temperatures withstands 10,000 operations at rated voltage and current or between –40°C and +85°C. withstands 50 operations of 600% AC or 1000% DC rated current at rated voltage followed by 6000 operations at rated voltage and current, in accordance with UL 1077. AUxIlIARY SwITCH RATINGS (SIlVeR) 3.0 amps @ 120VAC — 1.5 amps @ — 32VDC AUxIlIARY SwITCH RATINGS (GOlD) .100 amps @ 32VAC 32VDC AGeNCY APPROVAlS Voltage (Volts) Rated Current (Amps) Interrupting Capacity, Amps Max Voltage frequency (Hz) Phase Min Poles Ul/CSA Ul1077 & CSA Max Series fuse 32 DC — 1 .05 to 50 2500 none 65 DC — 1 .05 to 30 2000 none 130 DC — 2 .05 to 15 1000 none 120 50/60 1 1 .05 to 50 3600 200 120 / 240 50/60 1 2 .05 to 50 1000 none 240 50/60 1 & 3 1 .05 to 10 5000 40 250 50/60 1 & 3 1 .05 to 50 1000 none 250 50/60 1 & 3 1 .05 to 50 3650 80 277 50/60 1 1 .05 to 30 1000 120 277 50/60 1 1 .05 to 10 5000 40 125 400 1 1 .05 to 30 2000 none 240 400 1 & 3 1 .05 to 20 2100 80 250 400 1 & 3 1 .05 to 30 1000 none 250 400 1 & 3 1 .05 to 30 3500 125 277 400 1 1 .05 to 20 1000 80 Notes: Series fuse to be a branch-circuit UL approved type K-5 back-up fuse rated at not more than four times the rating of the highest-rated type UPG (15 amps minimum) 136 APG/UPG/IPG Series - Specifications http://airpax.sensata.com/ Moisture Resistance APPROxIMATe weIGHT PeR POle Meets all the requirements of MIL-PRF-55629 when tested in Series Ounces Grams accordance with Method 106 of MIL-Std. 202. APG/UPG/IPG 2.2 60.5 APGN/UPGN 3.0 76.2 Salt Spray (Corrosion) Meets requirements of MIL-PRF-55629 when tested in accordance with Method 101 of MIL-Std. 202. All APG/UPG protectors are constructed with stainless steel springs and plated parts. In addition to meeting normal requirements for moisture and salt spray resistance, the protector meets the fungus resistance requirements of MIL-PRF-55629. ReCOMMeNDeD TORQUe SPeCIfICATIONS Poles Component Torque (in-lbs) One through four poles with the UPGH, one through three 6-32 Mounting Inserts 6 to 8 poles with all other types. M3 Mounting Screws 4 to 5 8-32 Screw Terminals 10 to 12 MIl-PRf-55629 (APG) Single, two and three pole versions, with and without the M4 Terminal Screws 10 to 12 auxiliary switch option, have been qualified to MIL-PRF-55629. 10-32 Screw Terminals 14 to 15 M5 Screw Terminals 14 to 15 Construction 1/2 - 32 Mounting Bushing 30 to 35 Series, shunt, relay, dual coil, tapped coil, voltage trip, no-voltage trip, auxiliary switch, switch only. Various delays Where applicable, mechanical support must be provide to the terminals when and combinations. applying torque Shock withstands 100G or more without tripping while carrying full rated current per MIL-Std. 202, Method 213, Test Condition I. Instant trip protectors are tested at 80% of rated current. Vibration withstands 10G without tripping while carrying full rated current per MIL-Std. 202, Method 204, Test Condition A. Instant trip protectors are tested at 80% of rated current. http://airpax.sensata.com/ APG/UPG/IPG Series - Specifications 137 APG/UPG/IPG 1 3 4 First Decision Third Decision Fourth Decision APG / UPG Decision Table - How to Order Type Internal Configuration Hz and Delay The ordering code for APG/UPG circuit protectors may be Type Description -40 400Hz 150% instant trip Switch only (omit 4th and -0 determined by following the steps in the decision tables 5th decisions) APG One handle per unit -41 400Hz short delay shown here. -1 Series UPG One handle per unit -42 400Hz long delay UL Recognized and -1REC4 Auxiliary switch* The coding given permits a self-assigning part number but CSA Certified -43* 400Hz motor start .110 quick-connect with certain limitations. Units with mixed ratings, APGX One rocker handle per unit -49 400Hz 130% instant trip -1REG4 Auxiliary switch* (Gold combinations of styles, or constructions not listed in the Contacts) .110 quick-connect third decision table, require a factory-assigned part UPGX One rocker handle per -50 DC 150% instant trip unit UL Recognized and number. with these, it is suggested that order entry be by -1REC5 Auxiliary switch* CSA Certified -51 DC short delay .187 quick-connect description and/or drawings, and a part number will be Panel seal APGN -52 DC long delay -3 Shunt (up to 30 amperes only) established. Additionally, it is standard policy to establish a (one bat handle per unit) factory-assigned part number whenever a descriptive -53* DC motor start -4 Relay (up to 30 amperes only) drawing exists to provide cross reference, traceability and Panel seal (one bat handle *Only one auxiliary switch is normally supplied on two and three pole units. UPGN -59 DC 125% instant trip manufacturing control. per unit) UL Recognized and Can be used for solder terminals also. Switch is located in the right-hand pole CSA Certified (viewed from terminal end) unless otherwise specified. Multi-pole units with -60 50/60Hz 150% instant trip mixed construction, poles numbered left to right when viewed from terminal when specifying a circuit protector for AC motor start or One handle per pole APGH -61 50/60Hz short delay end. high inrush applications, the peak amplitude and surge One handle per pole UPGH -62 50/60Hz long delay duration should be specified for factory assistance in UL Recognized and CSA Certified -600* 50/60Hz motor start delay 7 rating selection. Seventh Decision One rocker handle per pole APGHX -64 50/60Hz, short delay Handle/Actuator Color** (high pulse) For example, the following is the code for a single pole One rocker handle per pole UPGHX Toggle Handle Color † UPG, quick-connect type terminal series unit with auxiliary UL Recognized and -65 50/60Hz, long delay CSA Certified (high pulse) switch, designed for operation in a 50/60Hz circuit. It has a -01 Black w/ white markings Example: short time delay and a rating of 20 amperes. A white -66* 50/60Hz, motor start -11 Yellow w/ black markings (high pulse) handle is specified by the seventh decision table. 2 Second Decision -21 Red w/ white markings UPG 1- 1REC4- 61- 203- 09 -69 50/60Hz 125% instant trip Poles (Note A) To determine the ordering number for your particular APG/ -31 Blue w/ white warkings -71 DC, 50/60Hz short delay Number Number UPG unit, simply follow the steps shown. You may use this Quick- Screw 1 23 45 7 -41 Green w/ white markings Connect of poles of poles Terminals -72 DC, 50/60Hz long delay number to place an order or as a reference for further Terminals -91 White w/ black markings questions you may have. -73* DC, 50/60Hz motor start delay Single pole unit Single pole unit 1 6 Rocker/Actuator Color For addition of inertial delay, add an “F” to any delay number. * Not available above 30 amperes. T Two pole unit wo pole unit 11 66 -00 Black w/o markings Notes: 666 Three pole unit Three pole unit 111 -01 Black w/ white markings A It is recommended that power leads be soldered to protectors Four pole unit Four pole unit 1111 6666 having quick-connect terminals for current trip ratings above 10 -02 Red w/o markings 5 Fifth Decision (Note D) (Note D) amperes. -05 Opaque white w/o markings B The standard current values for 100% of rated current are listed. Rated Current (Note B) Please consult an Airpax office or sales representative for other -08 Gray w/o markings Current Ratings Ratings values. Current Code (Amps) (Amps) C UL recognized and CSA certified applications above 30 amperes Code -09 Translucent white w/o markings are restricted to loads having a power factor of 75 minimum -103 10.0 -101 .100 -21 Red w/ white markings and limited to 32Vdc only. Standard terminals on ratings over 30 amperes are 10-32 screw type. -251 .250 -153 15.0 -51 Opaque white w/ black markings D Four pole protectors are available only in the APGH/UPGH and -501 .500 -203 20.0 APG/UPG types. The APGH/UPGH four pole provides one handle 6 Sixth Decision -81 Gray w/ black markings per pole, while the APG/UPG four pole has handles in the center -751 .750 -303 30.0 Optional two poles only, for simplified mounting. Translucent white w/ black markings -91 E Sub panel mount available in APGX/UPGX configuration only. -102 1.0 -353 35.0* **Not available for bat handle. -A Metric thread mounting (Not F when “A” is specified in the sixth decision in conjunction with available on APGN/UPGN) (Note F) †Unmarked handles are available. Please consult factory. -403 -252 2.5 40.0* APG/UPG-6 type, metric screw terminals are supplied. Sub panel mount (Note E) -B G If a circuit breaker is marked in this manner, it means 277V per -502 5.0 -503 50.0* pole – single phase source. Thus, if a two or three pole unit is 277Vac 50/60Hz (Note G) -C marked 277V, all line terminals must be connected to the same -752 7.5 phase, assuming the 277V is taken from line to neutral of 3 phase International handle markings -H Standard current ratings listed. For other ratings, 277/480V system. please consult factory. One or more descriptions may be used as required. If this table is not used, go directly to the seventh decision. 138 APG/UPG/IPG Series - APG/UPG Decision Tables http://airpax.sensata.com/ 1 3 4 First Decision Third Decision Fourth Decision Type Internal Configuration Hz and Delay Type Description -40 400Hz 150% instant trip Switch only (omit 4th and -0 5th decisions) APG One handle per unit -41 400Hz short delay -1 Series UPG One handle per unit -42 400Hz long delay UL Recognized and -1REC4 Auxiliary switch* CSA Certified -43* 400Hz motor start .110 quick-connect APGX One rocker handle per unit -49 400Hz 130% instant trip -1REG4 Auxiliary switch* (Gold Contacts) .110 quick-connect UPGX One rocker handle per -50 DC 150% instant trip unit UL Recognized and -1REC5 Auxiliary switch* CSA Certified -51 DC short delay .187 quick-connect Panel seal APGN -52 DC long delay -3 Shunt (up to 30 amperes only) (one bat handle per unit) -53* DC motor start -4 Relay (up to 30 amperes only) Panel seal (one bat handle *Only one auxiliary switch is normally supplied on two and three pole units. UPGN -59 DC 125% instant trip per unit) UL Recognized and Can be used for solder terminals also. Switch is located in the right-hand pole CSA Certified (viewed from terminal end) unless otherwise specified. Multi-pole units with -60 50/60Hz 150% instant trip mixed construction, poles numbered left to right when viewed from terminal One handle per pole APGH -61 50/60Hz short delay end. One handle per pole UPGH -62 50/60Hz long delay UL Recognized and CSA Certified -600* 50/60Hz motor start delay 7 Seventh Decision One rocker handle per pole APGHX -64 50/60Hz, short delay Handle/Actuator Color** (high pulse) One rocker handle per pole UPGHX Toggle Handle Color † UL Recognized and -65 50/60Hz, long delay CSA Certified (high pulse) -01 Black w/ white markings Example: -66* 50/60Hz, motor start -11 Yellow w/ black markings (high pulse) 2 Second Decision -21 Red w/ white markings UPG 1- 1REC4- 61- 203- 09 -69 50/60Hz 125% instant trip Poles (Note A) -31 Blue w/ white warkings -71 DC, 50/60Hz short delay Number Number Quick- Screw 1 23 45 7 -41 Green w/ white markings Connect of poles of poles Terminals -72 DC, 50/60Hz long delay Terminals -91 White w/ black markings -73* DC, 50/60Hz motor start delay Single pole unit Single pole unit 1 6 Rocker/Actuator Color For addition of inertial delay, add an “F” to any delay number. * Not available above 30 amperes. T Two pole unit wo pole unit 11 66 -00 Black w/o markings 666 Three pole unit Three pole unit 111 -01 Black w/ white markings Four pole unit Four pole unit 1111 6666 -02 Red w/o markings 5 Fifth Decision (Note D) (Note D) -05 Opaque white w/o markings Rated Current (Note B) -08 Gray w/o markings Current Ratings Ratings Current Code (Amps) (Amps) Code -09 Translucent white w/o markings -103 10.0 -101 .100 -21 Red w/ white markings -251 .250 -153 15.0 -51 Opaque white w/ black markings -501 .500 -203 20.0 6 Sixth Decision -81 Gray w/ black markings -751 .750 -303 30.0 Optional Translucent white w/ black markings -91 -102 1.0 -353 35.0* **Not available for bat handle. -A Metric thread mounting (Not available on APGN/UPGN) (Note F) †Unmarked handles are available. Please consult factory. -403 -252 2.5 40.0* Sub panel mount (Note E) -B -502 5.0 -503 50.0* 277Vac 50/60Hz (Note G) -C -752 7.5 International handle markings -H Standard current ratings listed. For other ratings, please consult factory. One or more descriptions may be used as required. If this table is not used, go directly to the seventh decision. http://airpax.sensata.com/ APG/UPG/IPG Series - APG/UPG Decision Tables 139 APG/UPG/IPG IPG Decision Table - How to Order 4 5 Fourth Decision Fifth Decision The ordering code for IPG circuit protectors may be Hz and Delay Nominal Amperage Rating determined by following the steps in the decision tables -40 400Hz 150% instant trip Current Ratings Current Ratings shown here. 1 First Decision Code (Amps) Code (Amps) -41 400Hz short delay Type -101 .100 -103 10.0 The coding given permits a self-assigning part number but -42 400Hz long delay with certain limitations. Units with mixed ratings, Std. Handle Color Type Description -251 .250 -153 15.0 -43* 400Hz motor start combinations of styles, or constructions not listed in the IPG Single pole with one Black 20.0 -501 .500 -203 third decision table, require a factory-assigned part handle per unit (Not -49 400Hz 130% instant trip number. with these, it is suggested that order entry be by available in multi-pole -751 .750 -303 30.0 -50 DC 150% instant delay configuration) description and/or drawings, and a part number will be -102 1.0 -353 35.0* -51 DC short delay established. Additionally, it is standard policy to establish Black IPGH Multi-pole with -252 2.5 -403 40.0* handle per pole a factory-assigned part number whenever a descriptive -52 DC long delay drawing exists to provide cross reference, traceability and -502 5.0 -503 50.0* -53* DC motor start manufacturing control. -752 7.5 -59 DC 125% instant trip Standard current ratings listed. For other ratings, when specifying a circuit protector for AC motor start or please consult factory. -60 50/60Hz 150% instant trip high inrush applications, the peak amplitude and surge -61 50/60Hz short delay duration should be specified for factory assistance in rating -62 50/60Hz long delay selection. 2 Second Decision -64 50/60Hz, short delay Poles (high pulse) For example, the following is the code for a single pole IPG, quick-connect type terminal series unit with auxiliary Number Push-On Screw -65 50/60Hz, long delay Terminals of poles Terminals (high pulse) switch, designed for operation in a 50/60Hz circuit. It has a short time delay and a rating of 20 amperes. Metric Single pole 1 6 -66* 50/60Hz, motor start (high pulse) mounting inserts and a white handle are also specified. Two pole 11 66 -69 50/60Hz 125% instant trip Three pole 6 111 666 Sixth Decision To determine the ordering number for your particular IPG For addition of inertial delay, add an “F” to any delay number. * Not available above 30 amperes. unit, simply follow the steps shown. You may use this Optional Four pole 1111 6666 number to place an order or as a reference for further (Note E) -A Metric thread mounting questions you may have. Example: When this table is not used, table 7 may be substituted and U.S. thread will be supplied. IPG 1 - 1REC4 - 61 - 203 - A - 00 - V Notes: A It is recommended that power leads be soldered to protectors having push-on terminals for current trip ratings above 10 amperes. 3 Third Decision 1 23 4 5 6 7 V B The standard current values for 100% of rated current are listed in the fifth Internal Configuration decision table. Please consult an Airpax office or sales representative for other values. Switch only (omit 4th and 7 C All IPG protectors meet normal requirements for moisture and salt spray Seventh Decision 5th decisions) resistance. IPG and IPGH D UL recognized and CSA certified applications above 30 amperes are Series restricted to loads having a power factor of .75 minimum, and limited to Toggle Handle Color 32Vdc only. VDE approval above 30 amperes is restricted to 32Vdc and Auxiliary switch* .110 quick-connect 120Vac 50/60Hz. Standard terminals on ratings over 30 amperes are 10-32 -00 Black screw type. V = VDE Approved Auxiliary switch* (Gold -10 Yellow E when “A” is specified in the sixth decision in conjunction with IPG-6 type, Contacts) .110 quick-connect metric screw terminals are supplied. The shaded areas denote VDE approval options. -20 Red Auxiliary switch* This approval requires the addition of a V at the end .187 quick-connect -30 Blue of the part number. The V will be added to any part number formed entirely from shaded decisions. Shunt (up to 30 amperes only) -40 Green If non-shaded areas are selected, the unit will not *Only one auxiliary switch is normally supplied on two and -90 White be VDE approved, but other approvals still apply. three pole units. Switch is located in the right-hand pole (viewed from terminal end) unless otherwise specified. 140 APG/UPG/IPG Series - IPG Decision Tables http://airpax.sensata.com/ 4 5 Fourth Decision Fifth Decision Hz and Delay Nominal Amperage Rating -40 400Hz 150% instant trip Current Ratings Current Ratings 1 First Decision Code (Amps) Code (Amps) -41 400Hz short delay Type -101 .100 -103 10.0 -42 400Hz long delay Std. Handle Color Type Description -251 .250 -153 15.0 -43* 400Hz motor start IPG Single pole with one Black 20.0 -501 .500 -203 handle per unit (Not -49 400Hz 130% instant trip available in multi-pole -751 .750 -303 30.0 -50 DC 150% instant delay configuration) -102 1.0 -353 35.0* -51 DC short delay Black IPGH Multi-pole with -252 2.5 -403 40.0* handle per pole -52 DC long delay -502 5.0 -503 50.0* -53* DC motor start -752 7.5 -59 DC 125% instant trip Standard current ratings listed. For other ratings, please consult factory. -60 50/60Hz 150% instant trip -61 50/60Hz short delay -62 50/60Hz long delay 2 Second Decision -64 50/60Hz, short delay Poles (high pulse) Number Push-On Screw -65 50/60Hz, long delay Terminals of poles Terminals (high pulse) Single pole 1 6 -66* 50/60Hz, motor start (high pulse) Two pole 11 66 -69 50/60Hz 125% instant trip Three pole 6 111 666 Sixth Decision For addition of inertial delay, add an “F” to any delay number. * Not available above 30 amperes. Optional Four pole 1111 6666 (Note E) -A Metric thread mounting Example: When this table is not used, table 7 may be substituted and U.S. thread will be supplied. IPG 1 - 1REC4 - 61 - 203 - A - 00 - V 3 Third Decision 1 23 4 5 6 7 V Internal Configuration Switch only (omit 4th and 7 Seventh Decision 5th decisions) IPG and IPGH Series Toggle Handle Color Auxiliary switch* .110 quick-connect -00 Black V = VDE Approved Auxiliary switch* (Gold -10 Yellow Contacts) .110 quick-connect The shaded areas denote VDE approval options. -20 Red Auxiliary switch* This approval requires the addition of a V at the end .187 quick-connect -30 Blue of the part number. The V will be added to any part number formed entirely from shaded decisions. Shunt (up to 30 amperes only) -40 Green If non-shaded areas are selected, the unit will not *Only one auxiliary switch is normally supplied on two and -90 White be VDE approved, but other approvals still apply. three pole units. Switch is located in the right-hand pole (viewed from terminal end) unless otherwise specified. http://airpax.sensata.com/ APG/UPG/IPG Series - IPG Decision Tables 141 APG/UPG/IPG

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the UPG1-1REC5-60-101-21 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Airpax UPG Series of Circuit Protection Devices. One Handle per Unit. UL Recognized & CSA Certified.

TOGGLE HANDLE CIRCUIT BREAKER

CIRC BREAKER

CIRCUIT BREAKER

product

Airpax UPG6-1-72-203-01 Thermal Magnetic Circuit Breaker

product

Airpax UPG66-1-66-303-01 Magnetic Circuit Protector